225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators



Similar documents
Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Air damper actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Quick running actuator

Electric Rotary Actuator - On/Off or programmable control actuator

HERZ-Thermal Actuators

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

80 Series - Modular timers 16 A. Features

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

E-STOP relays, safety gate monitors

48 SERIES Relay interface modules 10 A

Safety automation solutions

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

PNOZsigma - Base units

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Electronic Control Devices The European Product Catalogue 2007

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

VAV system solution for non-pressure-dependent applications in enclosed spaces

38 Series - Relay interface modules A

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

80 Series - Modular timers 16 A. Features

Product and functional description

Analog signal converters CC-E I/I Current / current isolators

VAV compact controller KNX / PL-Link

38 Series - Relay interface modules A

VAV compact controller KNX / PL-Link

3-phase, bidirectional energy meter

SMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA

Electronic Control Devices The European Product Catalogue 2007

49 Series - Relay interface modules A. Features

Digital input modules

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Redundancy Module QUINT-DIODE/40

! WARNING. Before using product, read and understand instructions.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Installation & User Instructions

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

MasterINTERFACE 39 Series - Relay interface modules

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Three-phase monitoring relay CM-PFE

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

MasterINTERFACE 39 Series - Relay interface modules

Contact expander modules

E-STOP relays, safety gate monitors

13 SERIES. Electronic step relays A

Electronic overload relay EF65, EF96 and EF146

Installation Instructions

RY2 miniature industrial relays

Quick Connect. quick - simple - efficient.

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

E-STOP relays, safety gate monitors

Safety technique. Emergency stop module BO 5988 safemaster

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Contact expansion modules

Drayton Digistat +2RF/+3RF

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Series 6000 Torque measured metal bellow coupling

Electronic overload relay EF19 and EF45

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RM4TG20 three-phase network control relay RM4-T - range V

Actuator for modulating control AME 435

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Cable Plug acc. to DIN EN , Form A

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

E-STOP relays, safety gate monitors

Heating Controller. Building Technologies HVAC Products

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Proportional pressure regulators VPPE

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

EBS852 (Contrac) Power Electronic Unit

Operating instructions IV / 2007

TX OPEN RS232/485 module

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Protect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Capteur température et humidité pour HVAC

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Transcription:

Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5 Nm Nominal Voltage 230 VAC/DC Control 2/3 Point Connection 2x freely adjustable Auxiliary switch S2 Damper size up to approx. 1 m² Damper coupling Clamp 8-12 mm / Ø 8-16 mm Technical data Nominal voltage Nominal voltage 230 VAC/DC Nominal voltage range 80...265 VAC/DC Power consuption Motor (Motion) 1,5 W Power consuption Standby (end position) 1,0 W Wire sizing 3,5 VA Control 2/3 point Position feedback - Auxiliary switch 2x SPDT (Ag) Contact load 5 (2,5) A, 250 VAC Switching point 0...95 Connection Motor screw terminals, on cable 0,5...1,5mm² Connection Auxiliary switch screw terminals, on cable 0,5...1,5mm² Connection Position feedback - Connection GUAC - Functional data Torque Motor > 5 Nm Synchronised speed - Direction of rotation selected by switch Manual override Gearing latch disengaged with pushbutton, self-resetting Angle of rotation 0... max. 95 Can be limited with adjustable mechanical end stop min 20 Running time Motor 60...120 s / 90 Sound power level Motor < 35 db(a) Damper coupling clamp 8-12 mm/ Ø 8-16 mm 2013-07-30 10:36:54 Copyright by GRUNER AG Subject to change in technology and Design 1

Technical data Functional data Position indication mechanical with pointer Service life > 60'000 cycles (0-95 - 0 ) Safety Protection class II (double insulation) Degree of protection IP 52 (Cable port downwards) EMC CE (2004/108/EG) LVD CE (2006/95/EG) RoHS CE (2011/65/EU) Mode of operation Typ 1 (EN 60730-1) Rated impulse voltage 4 kv (EN 60730-1) Control pollution degree 3 (EN 60730-1) Ambient temperature Normal operation -30...+50 Storage temperature -30...+80 Ambient humidity 5...95% r.f., non- condensating (EN 60730-1) Maintenance maintenance free Dimensions/ Weight Dimensions 145 x 65 x 61 mm Weight ca. 530 g Operating mode / Properties Operating mode 2- point. Through connecting the power supply to 1+2 and the direction of rotation switch on position R moves the actuator to position 1. Is also 1+2+3 connected to the power supply the actuator is moving to position 0. 3- point. Through connecting the power supply to 1+2 and the direction of rotation switch on position R moves the actuator to position 1. If the power supply is interrupted the actuator maintains its current position. Is also1+3 connected to the power supply the actuator is moving in direction 0. The actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Signaling The two integrated auxiliary switches are freely adjustable in the angle of 0 95. These are activated corresponding to the adjusted angle. The damper position can be checked by the mechanical pointer. Direct mounting Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with an anti-rotation strap to prevent the actuator from rotating. Manual override Manual override is possible with the self-resetting pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed) Rotary direction switch R/CW= clockwise L/ CCW= counter clockwise 2013-07-30 10:36:55 Copyright by GRUNER AG Subject to change in technology and Design 2

Connection / Safety remarks Safety remarks -Attention mains voltage -The actuator is not allowed to be used outside the specified field of application, especially in airplanes. -In may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. -The device may only be opened at the manufacturer s site. -When calculating the required torque, the specifications supplied by the damper manufacturers (cross- section, design, installation site), and the air flow conditions must be observed. -The actuator is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. 2013-07-30 10:36:55 Copyright by GRUNER AG Subject to change in technology and Design 3

Technical drawing 2013-07-30 10:36:56 Copyright by GRUNER AG Subject to change in technology and Design 4