Winnipeg Water Treatment Program



Similar documents
GLOSSARY OF TERMINOLOGY

Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations

SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

METHOD STATEMENT HIGH STRIAN DYNAMIC TESTING OF PILE. Prepared by

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils

Asset Data Dictionary Definition Document Continuous Flight Auger Piles (CFA) Uniclass Classification

An Automatic Kunzelstab Penetration Test

Anirudhan I.V. Geotechnical Solutions, Chennai

INSTALLATION SPECIFICATION FOR DRIVEN PILES

EARTHWORKS COMPLETION REPORT ELLEN STIRLING PARADE, ELLENBROOK. Ellenbrook, W.A. Georgiou Group Pty Ltd

Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples

Work Type Definition and Submittal Requirements

PDCA Driven-Pile Terms and Definitions

KWANG SING ENGINEERING PTE LTD

Mersin, TURKEY. Port extension project

DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL

Cold Weather Concrete Practices

Geotechnical Investigation Test Report

Foundation Underpinning Process and Relationship with Groundwater in West- Central Florida

ENTRY FORM. DVASE 2013 Excellence in Structural Engineering Awards Program

APPENDIX F GEOTECHNICAL REPORT

CARLOS FERNANDEZ TADEO & ASOCIADOS, S.L. Range of Services

Kentucky Lake Bridge Pile Load Testing Overview Ohio Transportation Engineering Conference Columbus, Ohio 10/28/2015

Teksam Pipe Cast CV 2600


Manitoba Curriculum Framework of Outcomes Refrigeration & Air Conditioning Overview 2013 Draft

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

CPME CABLE PUSHING MACHINE WITH ELECTRIC MOTOR. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

STATIC PILE LOAD TEST MANUAL. GEOTECHNICAL CONTROL PROCEDURE GCP-18 Revision #4

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Offshore Work Packages

Recycling of Mineral Wool Composite Panels Into New Raw Materials

PRODUCTS PRODUCTS ABOUT US.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HYDROFOK MACHINES. HYDRAULIC CABLE & TUBE BLOWING MACHINE with HYDRAULIC POWER UNIT) fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

PART E SPECIFICATIONS

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

California Department of Transportation Doyle Drive Test Program Contract No. 04A3362

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

AURORA-RIETVLEI SOLAR POWER (PTY) LTD.

RATCHET RELEASE SHACKLE

How strong are magnets?

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY

Measuring the Diameter of the Sun

D3O PARTNER MARKETING SUPPORT TOOLS

Service & Maintenance Packages. Service & After-Sales. A Strong Company

Contents General Requirements Location Size Inlet and Outlet Piping Protection Security Electrical Automatic Meter Reading (AMR)

PROVA DINAMICA SU PALI IN ALTERNATIVA ALLA PROVA STATICA. Pile Dynamic Load test as alternative to Static Load test

High Strain Dynamic Load Testing of Drilled Shafts

Standard Test Procedures Manual

Airport Rail Link is gathering speed. Wolfgang Rueprich, Project Manager Airport Rail Link, October 21, 2009

European Technical Approval ETA-12/0500

MINIFOK MACHINES MINI FIBER OPTIC CABLE BLOWING MACHINE. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

METHOD OF STATEMENT FOR STATIC LOADING TEST

A guide to volume measurement solutions for the. Mining Industry. Changing the market from level to volume

Technical Manual - Section 1 Introduction to Lytag lightweight aggregate

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Important Points: Timing: Timing Evaluation Methodology Example Immediate First announcement of building damage

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version Roseland Drive Macedonia, Ohio

SERVICING REPORT SITE PLAN AND PLAN OF CONDOMINIUM BLOCK 53 FERRIS DRIVE PLAN 58M-379 & PART OF LOT 4, REGISTERED PLAN 622 WELLESLEY, ONTARIO

Solving Persistent Moisture Problems and Moisture Damage

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

DECLARATION OF PERFORMANCE NO. HU-DOP_TN _001

Build in self resetting protection systems: short circuit, overwattage overvoltage, thermal.

Partnerships Implementing Engineering Education Worcester Polytechnic Institute Worcester Public Schools

SECTION 700 STRUCTURES SECTION 701 DRIVEN PILING MATERIALS Materials Materials shall be in accordance with the following:

Vegyesipari Kereskedelmi és Szolgáltató kft

UPDATED FUNCTIONAL SERVICING and STORMWATER MANAGEMENT REPORT

WDC Whakatane Central Business District Geotechnical Investigation

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

Application for electricity connections Business premises

UNDERPINNING OF NEW STUDENT HOUSING BUILDING USING MICROPILES, NORTH CAROLINA USA

Pigeon Spike Stainless Economy Bird Spikes Includes specifications for: Pigeon Spike Stainless models, hardware and surface cleaning.

QUEENSLAND HEALTH POPULATION HEALTH QUEENSLAND INVESTIGATORS REPORT

Platform Carts. Growing Together

PVE Piling and Drilling Rigs Powerful, Versatile and Efficient. PVE Piling and Drilling Rigs B.V. Worldwide supply of specialized foundation machines

XVII. Science and Technology/Engineering, Grade 8

BIOMASS SUPPLY CHAIN MANAGEMENT AND CONTROLLING

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

SFI SPECIFICATION 61.1 EFFECTIVE: FEBRUARY 26, 2014

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

Ground-borne Vibrations and Ground Settlements Arising from Pile Driving and Similar Operations

The Smart Meter Revolution_

ELECTROFOK MACHINE. ELEKTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE with ELECTRIC)

Dynamic Load Testing of Helical Piles

Built for Power. Engineered to Last.

Transcription:

Winnipeg Water Treatment Program Test s Set 1

Test Pile Driving Summary Project: City of Winnipeg Water Treatment Plant Client: City of Winnipeg Contractor: Subterranean (Manitoba) Ltd. Project Number: 3398-055-00 Location: Proposed Clearwell Driving Date: March 2, 2005 Driving Hammer: Link Belt 520 Personnel: Follower 8.2m Pile Length: 19.0m Pile # Northing (m) Easting (m) Ground Elevation (m) Top of Pile (m) Tip Elevation (m) Pile Diameter (mm) Refusal Criteria* (bl /25 ) Final Set (mm) 9362 5524079.56 647811.39 237.20 233.55 214.55 400 15 22/19/13 8276 5524132.64 647788.49 236.95 233.65 214.65 400 15 19/13/13 8004 5524159.76 647798.73 237.02 235.04 216.04 400 15 25/20/20 8229 5524135.53 647785.42 236.90 233.95 214.95 400 15 25/19/19 8898 5524106.99 64776897 236.13 234.50 215.50 400 15 15/15/15 9249 5524089.58 647797.95 236.54 234.59 215.59 350 10 25/25/10 9024 5524101.65 647833.99 238.47 234.49 215.49 350 10 19/19/13 8807 5524110.47 647810.96 237.57 233.91 214.91 350 10 20/10/10 8187 5524137.99 647828.13 238.20 234.58 215.58 350 10 23/19/10 8438 5524125.03 647848.92 239.07 234.39 215.39 350 10 8/6/0 *Refusal criteria increased 25% due to Follower. P:\3398\055-00\4 Development\4 Test Results and Analysis\Pile Driving Summary.dot

400mm Pile Number: 9362 Pile Size: 400mm 237.20m Supplier #: P132 233.55m Ground Elevation: 237.20m Top of Pile: 233.55m Tip Elevation: 214.55m Refusal Criteria: 15 blows/25mm 9362 214.55m blows per 0.3 meters 15 16 22 25 28 35 60 90 Penetration for 15 blows (mm) - - - - 22 19 13

400mm Pile Number: 8276 Pile Size: 400mm Cast Date: 14-Feb-05 236.95m Supplier #: P152 233.65m Ground Elevation: 236.95m Top of Pile: 233.65m Tip Elevation: 214.65m Refusal Criteria: 15 blows/25mm 8276 214.65m blows per 0.3 meters 13 25 30 40 47 52 54 59 Penetration for 15 blows (mm) - 50 30 22 19 13 13

400mm Pile Number: 8004 Pile Size: 400mm Cast Date: 14-Feb-05 237.02m Supplier #: 235.04m Ground Elevation: 237.02m Top of Pile: 235.04m Tip Elevation: 216.04m Refusal Criteria: 15 blows/25mm 8004 216.04m blows per 0.3 meters Penetration for 15 blows (mm) 50 40 25 25 25 20 20

400mm Pile Number: 8229 Pile Size: 400mm Cast Date: 14-Feb-05 236.90m Supplier #: 233.95m Ground Elevation: 236.90m Top of Pile: 233.95m Tip Elevation: 214.95m Refusal Criteria: 15 blows/25mm 8229 214.95m blows per 0.3 meters 20 25 30 30 30 30 40 50 Penetration for 15 blows (mm) 40 35 30 25 25 19 19

400mm Pile Number: 8898 Pile Size: 400mm 236.13m Supplier #: P150 235.50m Ground Elevation: 236.13m Top of Pile: 235.50m Tip Elevation: 215.50m Refusal Criteria: 15 blows/25mm 8898 215.50m blows per 0.3 meters - - - - 26 26 31 38 Penetration for 15 blows (mm) - - 17 30 15 15 15

350mm Pile Number: 9249 Pile Size: 350mm 236.54m Supplier #: 234.59m Ground Elevation: 236.54m Top of Pile: 234.59m Tip Elevation: 215.59m Refusal Criteria: 10 blows/25mm 9249 -pile started to hang up before the follower was used (ie. Top of pile at grade). Normal driving after switching to the folower -pile stopped dead at 215.59m 215.59m blows per 0.3 meters - - 38 40 49 50 55 63 Penetration for 10 blows (mm) 50 45 45 40 25 25 10

350mm Pile Number: 9024 Pile Size: 350mm 238.47m Supplier #: P161 234.49m Ground Elevation: 238.47m Top of Pile: 234.49m Tip Elevation: 215.49m Refusal Criteria: 10 blows/25mm 9024 215.49m blows per 0.3 meters 6 10 25 80 Penetration for 10 blows (mm) 30 30 28 25 19 19 13

350mm Pile Number: 8807 Pile Size: 350mm 237.57m Supplier #: P162 233.91m Ground Elevation: 237.57m Top of Pile: 233.91m Tip Elevation: 214.91m Refusal Criteria: 10 blows/25mm 8807 214.91m blows per 0.3 meters - - 16 22 34 36 42 65 Penetration for 10 blows (mm) - - - 25 20 10 10

350mm Pile Number: 8187 Pile Size: 350mm 238.20m Supplier #: P160 234.58m Ground Elevation: 238.20m Top of Pile: 234.58m Tip Elevation: 215.58m Refusal Criteria: 10 blows/25mm 8187 215.58m blows per 0.3 meters - - - 17 17 23 24 50 Penetration for 10 blows (mm) - - 55 35 23 19 10

350mm Pile Number: 8438 Pile Size: 350mm 239.07m Supplier #: P164 234.39m Ground Elevation: 239.07m Top of Pile: 234.39m Tip Elevation: 215.39m Refusal Criteria: 10 blows/25mm - pile stopped dead at 215.39m 8438 215.39m blows per 0.3 meters - - - - 10 16 18 30 Penetration for 10 blows (mm) - - - - 8 6 0