Heat Integration Complicates Heat Pump Troubleshooting



Similar documents
PRACTICAL PROCESS HYDRAULICS CONSIDERATIONS

Optimization of Natural Gas Processing Plants Including Business Aspects

C. starting positive displacement pumps with the discharge valve closed.

How To Make A High Co 2 Gas Blend

Equipment Performance Monitoring

5.2. Vaporizers - Types and Usage

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Integrated Performance and Condition Monitoring at DuPont

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

NATURAL GAS EXPERIENCE

Dynamic Models Towards Operator and Engineer Training: Virtual Environment

Lecture 9 Solving Material Balances Problems Involving Non-Reactive Processes

Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design

Refrigeration Basics 101. By: Eric Nelson

Why and How we Use Capacity Control

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

LEAN LNG PLANTS HEAVY ENDS REMOVAL AND OPTIMUM RECOVERY OF LIGHT HYDROCARBONS FOR REFRIGERANT MAKE-UP

STEADY-STATE AND DYNAMIC SIMULATION OF CRUDE OIL DISTILLATION USING ASPEN PLUS AND ASPEN DYNAMICS

Design Guidelines for Using Distillation Simulation Software in the Field

Dry-out Design Considerations and Practices for Cryogenic Gas Plants

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

How To Clean Up A Reactor Water Cleanup

Long-Term Demonstration of CO2 Recovery from the Flue Gas of a Coal-Fired Power Station

Optimization of Water - Cooled Chiller Cooling Tower Combinations

The. Brendan P. Sheehan, Honeywell Process Solutions, USA, and Xin Zhu, UOP, a Honeywell Company, USA, explore energy optimisation in plant processes.

Understanding ejector systems necessary to troubleshoot vacuum distillation

Comparative Economic Investigation Options for Liquefied Petroleum Gas Production from Natural Gas Liquids

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

VACUUM REFRIGERATION SYSTEMS

IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1. Abstract. 1. Introduction

ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS

Fact Sheet Technology. Bergius-Pier Process (1)

Automobile Air Conditioning Primer

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

20,000 Barrel Per Day Crude Oil Refinery

Thermal Coupling Of Cooling and Heating Systems

Analysis of data centre cooling energy efficiency

Introduction to Process Engineering Economics. based on size of major equipment items allow to decide whether to invest in a detailed study

How To Make A Mine Guard Fosil Process

White Paper #10. Energy Efficiency in Computer Data Centers

ABSTRACT. aspects of potential waste heat recovery systems and the economics of installing them at selected survey factories.

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Performance Monitoring For Gas Turbines

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Production of R-134a

Turbo Tech 101 ( Basic )

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Natural gas liquids recovery from gas turbine fuel

PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS

Liquefied Natural Gas (LNG)

GEOTHERMAL POWER GENERATION A PRIMER ON LOW-TEMPERATURE, SMALL-SCALE APPLICATIONS

Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

HEATING, VENTILATION & AIR CONDITIONING

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

UNIT 2 REFRIGERATION CYCLE

The Different Types of Air Conditioning Equipment for IT Environments

********** An short and simple explanation of how oil is converted into gasoline and then brought to you, the consumer.

Why use Tigerloop in fuel heating systems?

UNDERSTANDING REFRIGERANT TABLES

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Routinely surveying tower overhead vacuum systems can

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

How To Understand Evaporator

The Challenge of Integrating Non-Continuous Processes Milk Powder Plant Case Study

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

Air-Conditioning Buying Guide

EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Enhancing Process Control Education with the Control Station Training Simulator

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

A Focus on Balance A Novel Approach Taking the Phillips Optimized Cascade LNG Process Into the Future

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Acetaldehyde Production by Ethanol Dehydrogenation

Making the Most of SáOá SM Services

Practical Implementation of Safety Management Systems at Unregulated Upstream Oil & Gas Facilities

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

By Steven C. Severini, P.E., Member ASHRAE

Oil Refinery Processes A Brief Overview

Design Procedure. Step 2: The simulation is performed next. Usually the column is not difficult to converge, as the liquid reflux ratio is large.

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Recommended Practice for Software Acquisition

Chapter 3.4: HVAC & Refrigeration System

Exergy: the quality of energy N. Woudstra

ON-VEHICLE INSPECTION

Glossary of Heating, Ventilation and Air Conditioning Terms

UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

HVAC Systems: Overview

Transcription:

Heat Integration Complicates Heat Pump Troubleshooting by Donald F. Schneider, PE Chemical Engineer Stratus Engineering, Inc. PMB 339 2951 Marina Bay Drive #130 League City, Texas 77573 (281) 335-7138 Fax: (281) 335-8116 e-mail: dfsstratus@aol.com Copyright 2001 Don Schneider

Introduction A naphtha fractionator unit had operated well for years but began to experience inexplicable warm weather trips of the heat pump compressor. During the summer the compressor would shut down on high discharge temperature for no apparent reason. Feed rates were high but not beyond design. The initial thought was that the compressor driver was inadequate. The compressor driver was due for overhaul it would be an opportune time to replace it with a high Horsepower machine. Focusing on the compressor would be easy, and it might even be correct. However, you could also buy a large Horsepower driver, put it in, and have the same problem. That would be an uncomfortable look-back meeting. Perhaps that is why so few project look-back meetings are held... The cost of a higher Horsepower driver was evaluated. It would be very expensive, but would be worth the expenditure if it worked. The unit outages during high product demand reduced production and raised maintenance costs. Before an order for a new compressor driver was placed though, a detailed review of the entire system was undertaken. Engineering is usually thought of as a cost. In this case, engineering was the best way to reduce costs. You could even conclude that engineering actually increased profits! 1

Heat Pumps A heat pump adds mechanical work to a low value energy source so that it can be transferred to a high value energy sink. In the Hydrocarbon Processing Industry heat pumps are typically employed in condensing and reboiling fractionation columns. The traditional column of Figure 1 is shown as a heat pump design in Figure 2. The Figure 1 condenser and reboiler exchangers and their associated utilities are replaced by the compressor and single exchanger of Figure 2. The heat pump system uses the column's overhead duty for reboil. This is made possible by the compressor which boosts the overhead stream's pressure and temperature so that it condenses in the reboiler against the column bottoms. Heat pumps derive their benefit from lower energy costs in comparison to traditional designs. The traditional design energy consumption is the sum of both the condensing and reboil duties while the heat pump energy consumption is only the compressor horsepower. For a particular column, the economic viability of a heat pump versus a traditional design is determined to a great degree by the temperature difference between the column's top and bottoms. The larger the column temperature difference, the higher the required compression ratio and compressor horsepower. The T sweet spot for heat pump applications is typically 20 to 40 degrees F. Low operating pressures that swell compressor size due to large volumetric flow rates, and high operating temperatures that push compressor design thermal constraints are two other conditions that exclude heat pumps from process consideration. Heat pump systems are more complicated and typically require a higher initial capital outlay than traditional designs. Their elimination of heating and cooling utilities and their lower energy consumption must overcome this burden for a profitable application. 2

System Figure 3 illustrates the system under review here. A naphtha stream is being fractionated to recover valuable products. The Depropanizer Bottoms is fed to the Debutanizer (DIB) of Figure 3 for C4's removal. The Debutanizer Overhead is sent to a Deisobutanizer where Isobutane is separated from n-butane. The Debutanizer is a typical design and has the added benefit that its overhead is used in part to reboil the Deisobutanizer. The DIB with an overall column temperature difference of ~30 F and an overhead pressure of ~70 psia is able to employ a heat pump for condensing and reboil. Warm weather has the following effects at the plant: Compressor driver capacity diminishes. Cooling water temperatures rise. Air-cooler capacity decreases. These factors conspired to induce repeated shutdowns of the DIB heat pump and the column it served during the summer. The outages were undesirable because of their negative effect on the unit and production, but also because they were unpredictable and recurring. Compressor The heat pump compressor was central to the investigation though its importance was diminished by later discoveries. Figure 4 is a sketch of the compressor with its minimum flow or surge control loop, also called a kickback. A flow meter on the compressor outlet opens the minimum flow loop if necessary to maintain compressor throughput above surge. Kickback loops often have a means to cool the compressor discharge thereby removing the heat of compression. If this is not done, as it is omitted in our case, the hot flow recycled to the compressor suction is heated to a higher temperature upon being compressed again by the machine. This quickly results in a compressor discharge temperature that threatens to damage the equipment. A high outlet temperature shutdown is in place to trip the machine for its protection. Every indication was that this sequence of events was causing the warm weather compressor trips. But what was causing the compressor flow to drop off? The compressor driver is a gas turbine. Gas turbines lose Horsepower in warm weather as air density decreases with rising temperature. This can partially be offset with scrubbing the inlet air with water which cools and humidifies the air (evaporative coolers). Since the failures occurred during the heat of summer, a warm air related Horsepower loss could be a factor. However, after allowing for this effect the driver still should have been able to meet production rates. Something else had to be at work. Gas turbines, simplified jet engines, wear and foul over time. Both mechanisms deteriorate the drive's capacity. Periodic water washing can restore part of the Horsepower lost to fouling, but over time unrecoverable losses buildup. The drive in this case was at its recommended overhaul point. Therefore it was known to be sub par when compared with design. These are real capacity losses that can be tracked over time and certainly an 3

overhaul was due. But the question was whether or not to overhaul the existing driver or replace it with a larger one. Again, allowing for the effect of end-of-run deterioration, the compressor should not have been tripping off-line. Hydraulics and Heat Exchange As it leaves the compressor, the DIB overhead stream is now hot enough and at a high enough pressure to condense in the DIB reboiler. The compressor discharge is sent to the DIB Reboiler (E-1) where it condenses before entering the DIB Reflux Drum (V-1). The DIB Reboiler also receives heat from the Debutanizer Overhead. Employing the heat pump and two process heat sources to reboil the DIB provided excellent energy efficiency. Still, something was going awry in the summer. The DIB reflux is cooled by an air-cooler and water cooler before it enters the column. Unfortunately, the water cooled exchanger had been out of service for some time due to tube leaks. This outage increased the compressor load approximately four percent versus it being in operation using hot summertime water. Together with the compressor driver capacity reductions due to hot air intake and end-of-run fouling, a case was building to explain the compressor trips. Certainly improving any or all of these items would upgrade compressor performance. But the accumulation of these constraints seemed to suggest a tower throughput limitation. They did not suggest the compressor would just unexpectedly shutdown. A hint to the true cause of the problem came when an operator mentioned that the DIB reflux drum (V-1) PSV lifted intermittently during the summer. Normally the DIB Reflux Drum operated at a pressure comfortably away from its PSV set pressure. Since it was an equilibrium drum, its pressure was determined by the temperature and composition of the material within. If the upstream Depropanizer were slipping lights to the Debutanizer the DIB overhead composition would change and the DIB Reflux Drum would pressure up. But this problem was never seen. The DIB overhead Isobutane concentration was high and very steady. The temperature in the drum must be increasing to pressure up V-1. What could cause the temperature in V-1 to rise? Some change in the DIB Reboiler was the only possible source of a substantial adjustment of the V-1 temperature. The Reboiler could be fouled, but it seemed unlikely as fouling was not something that would come and go with the sunshine. E-1 would be affected by a DIB bottoms composition change and by a DIB column pressure change. But neither of these things occurred. What was left then was the Debutanizer Overhead stream. Both the Debutanizer Overhead and the DIB Overhead enter E-1 to supply heat to the DIB. A shift in reboiler heat duty from the DIB Overhead stream to the Debutanizer Overhead would warm V-1. Additionally it might prevent the DIB Overhead from fully condensing in E- 1. This would lead to much higher pressure drops from E-1 to V-1. A composition change in the Debutanizer Overhead would result in a higher temperature that would affect E-1 operation. However, the culprit was identified as the Debutanizer pressure after walking past the Debutanizer Overhead Air-Cooler (E-2). 4

The Debutanizer Overhead Air-Cooler capacity had waned over the years. It was a large bank of coolers part of which had been taken out of service. Dirt and dust from the surrounding environment had fouled the fins. The old boy just wasn't what he used to be. Since there was adequate reboiler capacity, operations compensated for this by increasing the Debutanizer pressure in the summer. This worked very well. Debutanizer capacity was not impacted by warm weather. However, the deleterious effect on the DIB was not obvious. Increasing the column pressure at constant composition raises the overhead temperature. This increases the Debutanizer stream temperature driving force in E-1 thereby shifting duty away from the DIB Overhead. This resulted in two-phase flow from E- 1 to V-1 and in higher temperatures in V-1. Both of these effects raised the required compressor discharge pressure. Table 1 details necessary compressor discharge pressures for several scenarios. The Hot Weather case is deemed 'hypothetical' because it is really worse than shown in the table, though a compressor head 26% greater than design is bad enough. As soon as the process is unable to condense all the DIB Overhead Stream in E-1, vapor begins to travel to V-1. This vapor has no way of leaving the drum. Pressure builds until the PSV lifts behavior noted by operations. At the same time the compressor must push against a higher and higher delivery pressure and rising two-phase frictional losses. This higher head requirement moves the compressor back on its curve until its flow drops off enough to activate the minimum flow loop. This recirculated flow leads to a high temperature discharge trip. It happens rapidly and with no apparent reason. Figure 5 illustrates the vapor pressures of both column's overhead streams. These relationships define the importance of the E-1 heat balance. For example, a 10 F increase in V-1 temperature results in a V-1 pressure increase of ~15 psi. That is 26% of the compressor design head. And moving the V-1 temperature ten degrees is not that hard. Increasing the Debutanizer pressure 10 psi increases its overhead temperature ~10 F. Though not one for one, the Debutanizer Overhead temperature and the V-1 temperature are closely coupled. A seemingly small change in the Debutanizer pressure can easily overload the DIB compressor. Slowly over time unit operation had deteriorated revealing a process complexity that was always there but not apparent. The Debutanizer overhead was shutting down the plant when its temperature rose in the summer. It is not unusual for equipment to degrade over time: Compressor driver at end-of-run cannot produce start-of-run Horsepower. Reflux water cooled exchanger out-of-service due to tube failures. Air-cooler fin fouling and partially out-of-service. It also is not unusual to equate mitigation of these types of deficiencies with cost. Why fix these things? That just raises maintenance expenditures. In the end the choice was between spending a lot of money on a new compressor driver that might not do the job, and spending a little money on engineering that might turf up another answer. After reviewing the findings, the plant decided not to install the costly upgraded compressor driver. Rather they overhauled the existing driver, and cleaned and maintained their 5

exchanger systems. A new, larger compressor driver would have cost over ten times the cost of the engineering study and resulting maintenance AND it would not have improved the operation at all. The plant is back running through the summer months still sweating with the warmth, but with equipment that can take the heat! 6

Cool Utility Feed Product Hot Utility Figure 1 Traditional Column Product 7

Feed Product Figure 2 Heat Pump Column Product 8

Table 1 Required Compressor Outlet Pressure Description Original Design Winter Warm Weather Hypothetical Hot Weather Percent of Design Feed Rate 100 100 100 100 Required compressor pressure difference, psi 58 55 62 73 Compressor P percent of design 100% 95% 107% 126% 9

SIC PIC Deisobutanizer CWS C M PIC FIC E-2 Flooded Condenser V-1 LIC Debutanizer M AI AI FIC From Depropanizer FIC FIC TIC i C4 LIC Steam AIC M Gasoline LIC FIC E-1 Bypass Flow M n C4 AI Figure 3 System 10

FIC SIC Figure 4 - Compressor 11

120 110 100 Vapor Pressure, psia 90 80 70 DIB Ovhd Debutanizer Ovhd 60 50 40 80 85 90 95 100 105 110 115 120 125 130 135 140 Temperature, F Figure 5 Column overhead vapor pressures 12

Author Biography Don Schneider Don Schneider is President of Stratus Engineering, Inc., Houston, Texas. Previously he worked as a senior engineer for Stone & Webster Engineering, and as an operating and project engineer for Shell Oil Co. He holds a B.S. from the University of Missouri-Rolla, and an M.S. from Texas A&M University, both in chemical engineering. Don has authored or coauthored over a dozen technical papers and articles and is a registered professional engineer in Texas. Author's Previous Publications Improve Catalyst Removal Methods, D. Schneider, Hydrocarbon Processing, October, 2000. Practical Process Hydraulics Considerations, D. Schneider, M. C. Hoover, Hydrocarbon Processing, August, 1999. Plant Power Failure and its Indirect Effects: a Case Study, D. Schneider, Petroleum Technology Quarterly, Winter 1998/99. Select the Right Hydrocarbon Molecular Weight Correlation, D. Schneider, Chemical Engineering Progress, December, 1998. Steady-State Simulators for Design, D. Schneider, Chemical Processing, December, 1998. Build a Better Process Model, D. Schneider, Chemical Engineering Progress, April, 1998. "Deep Cut Vacuum Tower Processing Provides Major Incentives, D. Schneider, J. Musumeci, Hydrocarbon Processing, November, 1997. "Debottlenecking Options and Optimization," D. Schneider, Petroleum Technology Quarterly, Autumn 1997. "Programming, It's not Just for Programmers Anymore," D. Schneider, Chemical Engineering, May, 1997. Deep Cut Vacuum Tower Incentives for Various Crudes, D. Schneider, J. Musumeci, L. Suarez, Presented @ the AIChE 1997 Spring Nat l Mtg. Process Simulation: Matching the Computer s Perception to Reality, D. Schneider, Presented @ the AIChE 1997 Spring Nat l Mtg. Debottlenecking Economics - Maximizing Profitability with Minimum Capital, D. Schneider, Presented @ the NPRA 1997 Annual Mtg. Analysis of Alky Unit DIB Exposes Design, Operating Considerations, D. Schneider, J. Musumeci, R. Chavez, Oil & Gas Journal, September 30, 1996. How to Calculate Purge Gas Volumes, D. Schneider, Hydrocarbon Processing, November, 1993.