SWIMMING POOL HEAT PUMP Owners Manual



Similar documents
DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

SWIMMING POOL HEAT PUMP

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual

Heat Pump. Quick Start Guide Models: 035, 055, 075, 090, 115, 110, 120, 121, 135, 155, 156, & 175

Heat Pumps for Swimming Pools

Aerona Air Source Heat Pumps

SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE

Astral Pool Heat Pump

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Portable Air Conditioner

DX Series Heat Pump Genus Compliant

york air-conditioning products Residential & VRF News 2015

Dealer Sales & Service Guide

Overheating limit control

SWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual DURA - series

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

User manual. 086U6297 Rev. 9 EN

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Installation and maintenance instructions. Danfoss Vent

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

USER S MANUAL HSC-24A

ALL IN ONE. Heat Pump Water Heater

REMOTE CONTROL MANUAL

AIR CONDITIONER INSTALLATION MANUAL

WATER & POOL&FLOOR HEATERS OWNER S MANUAL. Including Installation Instructions and Warranty Information

Instruction manual for Firstline FCS12000CH

Hot Water. Heat pump water heaters. Residential and Commercial R410a

INSTALLATION & TECHNICAL MANUAL

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

CEILING CASSETTE FAN COIL UNIT

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +


Heat Pump Installation, Maintenance and Service Manual

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Technical data. Danfoss DHP-A

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

CE6500 Energy Recovery Ventilator

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

PANASONIC TROUBLE SHOOTING GUIDE

Operating Instructions Split System Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

SWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual DURATECH - series

OWNER S Manual PRINTED IN CANADA 10/2009

Split Air Conditioner

Diesel Engine Driven Generators Page 1 of 6

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Heat Pump Water Heater IOM Manual

HP switch LP switch Discharge thermo Comp. Surface thermo

User manual. Atec. 086L0130 Rev. 1 EN

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

For installation guide see reverse of book

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Troubleshooting Your Refrigerator

PORTABLE AIR CONDITIONER

Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING

DUCT TYPE AIR CONDITIONER

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

G & F Manufacturing Swimming Pool Heat Pump

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

User manual. Solid (FR 98,),

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

INSTALLATION MANUAL. Address card EKAC10B

ECOCIAT. Domestic hot water heat recovery unit

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

User manual. 086U6297 Rev. 6 EN

Important Safeguards

Meaco 30L and Meaco 40L dehumidifier instruction manual

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

HERZ-Thermal Actuators

Geyser-R Heat pump water heater Installation manual

Oil and Coolant Circulating Heating System. Model - OCSM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Commercial Hot Water. Make a difference...

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Air Source Heat Pump Installation and Maintenance Manual

PORTABLE AIR CONDITIONER

SunMaxx Solar Filling Station Operating Instructions

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

CARING FOR YOUR WATER HEATER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Transcription:

SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor and a 5 year parts warranty on the titanium heat exchanger. Please contact your supplying dealer in the event of a claim. This heat pump is designed for domestic use between May and September. To achieve satisfactory performance a minimum ambient air temperature of 15 C is required. The heat pump needs to be run for a minimum of 8 hours in 24 during the warmest part of each day. A solar or heat retention swimming pool cover must be used. HeatSeeker Swimming Pool Heat Pump: Page 1 of 10

CONTENTS A. Positioning B. Connecting Pipe Work C. Sizes D. Starting the Heat Pump E. Setting the Temperature F. Checking the Status G. Changing the Mode H. Auxiliary Mode I. Winterising and Maintenance J. Troubleshooting: Error Codes K. Troubleshooting: Parameter Settings L. Accessories M. Technical Information HeatSeeker Swimming Pool Heat Pump: Page 2 of 10

A. Positioning Your Swimming Pool Heat Pump 1. For correct operation air must be free to circulate around the heat pump. Do not place the unit in a shed, greenhouse or similar. This unit is designed to be placed outdoors only. 2. Ensure there is at least 1000mm (1.0m) of clearance all around each side of the heat pump to allow air circulation and access for maintenance. 3. Do not block the top air exit where the fan expels air upwards from the unit. There must be no obstruction above this air exit for at least 2000mm (2.0m). 4. You should position the heat pump so that the control panel does not face directly towards the sun. 5. The heat pump must be upright. 6. The distance between the heat pump and the pool / plant room should be as short as practically possible to reduce pressure and heat loss in the pipe work. 7. Insulating the pipe work will assist with the prevention of heat losses. 8. An isolator switch should be installed (by a qualified electrician) near the heat pump. 9. The electrical supply to the heat pump must be protected by a 30mA RCD. 10. The air inlets and outlets must not be obstructed or blocked. 11. Even though the heat pump is low noise, it must be positioned so as to be considerate to neighbours. 12. Your heat pump must be placed on a solid base. 13. Condensation will drip from underneath the heat pump, your base must be able to tolerate this. B. Connecting Your Swimming Pool Pipe Work 1. The pool water is fed through the heat pump by a swimming pool pump. 2. The heat pump must be installed after (down stream) the swimming pool filter so clean, filtered water passes through it. 3. Double union ball valves must be fitted just before the heat pump inlet and just after the outlet to aid servicing and winterising. 4. Each heat pump has a maximum water flow rate. If the flow via the pool pump is higher than this then a by-pass should be installed. Consult your supplying dealer. 5. Each heat pump also has a minimum flow rate, below this the heat pump will not operate. Consult your supplying dealer. 6. Pipe work of less than 1½" diameter should not be used. 7. Fit a union nut onto each pipe. 8. Push the gasket over the pipe until the gasket is about 5-10mm from the edge of the pipe. You may need to lubricate the gasket. 9. Insert the pipe into the heat pump and tighten the union nut. 10. The union must only be hand tightened. 11. If the swimming pool is equipped with a chlorinator, brominator, or possibly chemical control with acid and chlorine pumps, these must be in the return pipe work after the heat pump and a non-return valve used. Any dosing system must be the final equipment before the water returns to the swimming pool. Damage caused to the heat pump by chemical dosing units is not covered by warranty. 12. Any heat exchanger or electric heater fitted as auxiliary heating must be installed after (down stream from) the heat pump so as to avoid pre-heating the pool water before it enters the heat pump. HeatSeeker Swimming Pool Heat Pump: Page 3 of 10

C. Sizes of Your Swimming Pool Heat Pump WBR-17.0H-A WBR-21.0H-A-S A 855 955 B 660 660 C 660 660 F 370 370 G 110 110 HeatSeeker Swimming Pool Heat Pump: Page 4 of 10

D. Starting Your Swimming Pool Heat Pump 1. Do not switch on the power to your heat pump unless your swimming pool pump is running and you have a good flow rate. Required flow rates are given in the technical information section. 2. Switch on the main power supply to the heat pump. The display will briefly show all options. Start / Stop Mode Set Aux 3. After a few seconds the display shows ROOM and a temperature. This is the temperature of the air surrounding the heat pump. 4. Push the START/STOP button and await the display to show the inlet and outlet temperature. 5. Note that when you first push the START/STOP button the heat pump fan and compressor will not start immediately. 6. If the water flow from the pool pump is correct, the heat pump will start after a 2-3 minute pause due to a delayed start facility. 7. When the heat pump is operational the display will show temperatures for the pool water inlet and outlet. HeatSeeker Swimming Pool Heat Pump: Page 5 of 10

E. Setting the Temperature of Your Swimming Pool Heat Pump 1. If your heat pump fan and compressor is running press the START/STOP button to make the heat pump enter its standby mode. 2. Press the set button repeatedly until SET NO 01 shows with the set point temperature in degrees C. 3. Use the up arrow button and the down arrow button to adjust the set point temperature to your desired point. If you have a liner type swimming pool do not exceed the recommended maximum temperature for the liner (often 28 C). 4. The display will return to the standby mode after a few seconds. 5. Restart the heat pump by pressing the START/STOP button. 6. After the 2 3 minute delay the heat pump will re-start with the new set temperature. F. Checking the Status of Your Swimming Pool Heat Pump 1. When the heat pump is running press the up or down arrow to scroll through the status readings as below. 2. IN & OUT are the respective temperatures at the water inlet and outlet. Note that when you have a good flow rate through the heat pump the difference may be less than 1 C so it appears there is no difference. 3. P1 is the temperature of condenser 1, P2 is the temperature of condenser 2. Note that some models have just one condenser so a reading may not be present for both P1 & P2. 4. ROOM is the temperature of the air around the heat pump. HeatSeeker Swimming Pool Heat Pump: Page 6 of 10

G. Changing the Mode of Your Swimming Pool Heat Pump 1. In some regions the swimming pool heat pump is equipped with the option to cool the swimming down. 2. Make sure the heat pump is in standby (power on but fan and compressor not running) by using the START/STOP button. 3. Press the MODE button to scroll through the available modes. 4. The snow flake symbol indicates cooling. 5. The sunshine symbol indicates heating. 6. The three arrows in a triangle is the automatic mode where the heat pump would choose to heat or cool the pool depending on the set temperature. 7. For pool heating in the UK keep the heat pump in the heating mode (sunshine symbol). 8. If pressing the MODE button does not change the mode and the heat pump remains in the heat mode (sunshine symbol) then the cooling and automatic modes have been deactivated. 9. If pressing the MODE button does not change the mode and the heat pump is not in the heating mode, firstly make sure you are in standby and then try again. If you can not change the mode at all refer to the troubleshooting (changing parameters) section. H. Auxiliary Mode of Your Swimming Pool Heat Pump 1. The AUX button on the heat pump is not used. 2. When pressed the AUX button may make a wavy line symbol appear and disappear on the display but no equipment is operated. I. Winterising and Maintenance of Your Swimming Pool Heat Pump 1. At all times only let swimming pool water through the heat pump which has the correct chemical balance. Chlorine not to exceed 3 ppm ph between 7.2 and 7.7 Total Alkalinity 90 150 ppm Calcium Hardness 100 400 ppm 2. When it is decided to close down the swimming pool for the winter it is important that the heat pump be immediately emptied of water. 3. Ensure that pool water can not freely flow out of the pool and then loosen both coupling nuts to the pipe work and withdraw the pipes from the heat pump. 4. Drain all the water from the heat pump. 5. Also empty the pipes. 6. The heat pump warranty does not cover frost damage. 7. The heat pump may be left outside all the year round but if you do have some room for the heat pump in a shed or garage, this will be a perfect place to keep it for the winter period. 8. You may wish to cover the heat pump to protect it from the worst weather conditions but do not wrap up the unit too tightly, let air circulate around it. 9. Do not lay the heat pump on its side, always store upright. HeatSeeker Swimming Pool Heat Pump: Page 7 of 10

J. Troubleshooting Your Swimming Pool Heat Pump: Error Codes 1. The most common problem reported is the heat pump showing a display but not running its fan and compressor. This is the time delay on start up. From pressing START/STOP there is a 2 3 minute delay before the fan and compressor start. 2. The second most common problem is insufficient flow through the heat pump indicated by EE 03. If your swimming pool filter has a multiport valve turn off the pool pump and turn the valve to recirculate, restart the pool pump and try the heat pump again. If this solves the problem make sure your sand filter is backwashed. 3. Another issue is not being able to operate the control panel at all. Look for a small padlock symbol on the display which means that the controls are locked. To release this press the up and down arrows together at the same time for about 5 seconds so that the padlock symbol disappears. 4. During the operating and defrosting process, the heat pump will yield a volume of condensed water. The condensed water from the cooling coil will drip from the bottom of the heat pump. Do not assume the condensed water is due to a fault or a leak in the heat pump. The table below shows error codes the heat pump may display Fault/Error Display Cause Action Water temperature in, sensor fault/error Water temperature out, sensor fault/error Coil 1 sensor fault/error Coil 2 sensor fault/error Ambient temperature sensor Too high difference in temperature in/out. PP 01 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 02 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 03 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 04 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 05 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 06 Water flow too low Check valves, filter pump, filter and by-pass Heating up PP 07 Water flow too low Check valves, filter pump, filter and by-pass First frost proofing run PP 08 Low out temperature Empty system of water Second frost PP 09 Low out temperature Empty system of water proofing run Function error in EE 01 Function error in print card Call technician system 1 Function error in EE 02 Input voltage too low Check main cable / system 2 electrician Flow guard error EE 03 Too small or too high flow Check pool pump, piping, by-pass and ball cocks. Check technical spec EE 04 Temperature EE 05 Water flow varying Check pool pump and fluctuations piping. Check valves, filter and by-pass Defrosting Logo Cold coil / element. None. Normal function Communication error EE 08 Communication error between control panel and control Check cable connection. Call technician HeatSeeker Swimming Pool Heat Pump: Page 8 of 10

K. Troubleshooting Your Swimming Pool Heat Pump: Parameter Settings 1. The heat pump has 11 control parameters from 00 to 10. 2. The parameters can be viewed but not changed while in operation mode. They can only be changed in stand-by mode. 3. Use the SET button to scroll through the parameters. 4. If you need to change a parameter make sure the heat pump is in standby mode. Parameter Description Range Default Setting Remarks 00 Setting of cooling temp 8 28 C 12 C For technician only 01 Setting of heat temp 15 40 C To be set by user 02 Defrosting period 30 90 min. 45 minutes For technician only 03 Coil temp. start 0 ~ -30 C 0 C For technician only defrosting 04 Coil temp. stop 2 30 C 13 C For technician only defrosting 05 Defrosting time 1 12 min 8 minutes For technician only 06 System number 1 2 1 May not be changed 07 Re-start after power 0 / 1 1 = ja. For technician only failure 08 Available Modes: Cooling only= 0 Heating + cooling = 1 0 3 3 For technician only Heating only= 3 09 Work method. 0 0 May not be changed 10 Setting of water temp. (auto mode ) 30 C 30 C For technician only 5. With the exception of Parameter 01 (setting the pool temperature set point) these parameters are usually only changed by a service technician. 6. Most parameters can not immediately be changed, even in standby mode. If you are sure you want to change a parameter proceed as below. 7. Before you change a parameter write down what it was set on. 8. In standby mode use the SET button to chose the parameter that needs changing. 9. Press the up and down arrows at the same time for about 5 seconds until you hear a small bleep. This unlocks the parameter to enable setting. 10. Use the up and down arrow to set the parameter to the new desired level. 11. After a few seconds the panel will revert to the standby mode with the new setting stored. 12. If you need to check the parameter setting use the SET button to display that parameter. L. Accessories The heat pump has a housing and cover plate to allow the digital control panel it to be mounted remotely if required. A 5m extension line with socket for this purpose is provided with the kit. HeatSeeker Swimming Pool Heat Pump: Page 9 of 10

M. Technical Information Code WBR-17.0H-A WBR-21.0H-A-S Rated Heating Capacity W 17000 21000 BTU s/hr 60000 73000 Input Power Heating W 3500 4250 Running Current Heating A 16.1 7.9 COP w/w 4.8 4.9 Power Supply v/ph/hz 220/1/50 Number of Compressors Compressor Type Rotary Scroll Number of Fans 1 1 Input Power of Fan W 200 200 Fan Rotation Speed rpm 830 830 Noise Level db 60 60 Water Connection inches 1½ 1½ Water Flow Rate m 3 /h 5-8 6-10 Water Pressure Drop KPa 16 16 L 660 660 Unit Dimension W H mm 660 860 660 960 L 700 700 Packing Dimension W H mm 740 1010 740 1110 Weight Net Gross kg 108 120 111 123 This product is CE marked. The HeatSeeker heat pump is tested to current EN standards: EN 55014-1:2001, EN 55014-2:1997, EN 61000-3-2:2001 and EN 61000-3-3:1995.LVD: EN 60335-2-40:2003, EN 60335-1:2002. HeatSeeker Swimming Pool Heat Pump: Page 10 of 10