Technical Specifications BIO-BLOK 80 HD G



Similar documents
SPECIFICATION FOR NOISEMASTER SOUND CONTROL PRODUCTS. Noisemaster Sailcloth Baffles shall be manufactured by THE PROUDFOOT CO., INC., Monroe, CT.

Apr 17, 2000 LAB MANUAL

Area & Volume. 1. Surface Area to Volume Ratio

Mold Preventing I nterior System

X-ray 100KV. Speed as compared to that of type IX100 used as a standard 100 under each exposure conditions.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

THERMA-TUBE preinsulated pipes and fittings Catalogue of products

CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN :2007

CHAPTER 29 VOLUMES AND SURFACE AREAS OF COMMON SOLIDS

Long term prediction of marble erosion for the conservation of the statue of David of Michelangelo

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

Morgue refrigeration unit

MERO Floor Systems - CleanRoom

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

REPAIR MANUAL MATERIALS

Butt Fusion Welding of HDPE Pipes Work Procedure

oil liquid water water liquid Answer, Key Homework 2 David McIntyre 1

MapeWrap EQ System. MapeWrap eq system...the safe answer for earthquakes

Quality control: Annex-A.

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

SPECIFICATION FOR CONSTRUCTION OF UNBOUND GRANULAR PAVEMENT LAYERS

FLUID MECHANICS. TUTORIAL No.4 FLOW THROUGH POROUS PASSAGES

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007

Ruční páskovače PRO PLASTOVÉ PÁSKY

Filter Aid Filtration

The University of Toledo Soil Mechanics Laboratory

12.1 Schlüter -KERDI-BOARD

How To Design A 3D Print In Metal

WATERPROOFING OF WET ROOMS

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

Lap Fillet Weld Calculations and FEA Techniques

THERMAL INSULATION ISOCOMPACT

Material data sheet. EOS Aluminium AlSi10Mg_200C. Description

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

Rooflight INSTALLATION INSTRUCTIONS

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

C O M P L E T I O N S E R V I C E S

Material data sheet. EOS Aluminium AlSi10Mg. Description

Wecryl Waterproofing System under surfacing supplied by others

( PULSA AQUI )

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

High Capacity Hot Air Dryer

LAB #3: MEASURING SPECIFIC GRAVITY AND DENSITY. Set-up and Materials for Experiment

FOREWORD. The Plastics Pipe Institute. This Technical Note, TN-30, was first issued in January 2006 and was revised and republished in September 2013.

Things you need to assemble the tube actuator. Left to right. are small piece of masking tape, super glue,pen knife and small

Calcite PH Nutralizer System

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference:

S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia

Repair of damaged rotor journal portion

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.

This test may be carried out with the IGT printability testers A1-3, A2-3 and AIC2-5 with the accompanying inking unit AE.

WPI Rapid Prototype Guidelines --Read entire document before submitting an order--

Figure 3. Pressure taps distribution around the bus model (64 pressure taps)

Thermal insulation. Don t be afraid of low temperatures. Institute for Technical Physics Holger Neumann

Metal Pressfitting Pipe Systems

Master Panel 1000 W Wall

Pipe Clamps and Accessories

Formwork for ventilated monolithic foundations.


UniPlate. Solar Collectors SOLAR SYSTEMS.

Chapter 16. Mensuration of Cylinder

LAB #11: RESONANCE IN AIR COLUMNS

The AASHO Road Test site (which eventually became part of I-80) at Ottawa, Illinois, was typical of northern climates (see Table 1).

Weight-for-age percentiles: Girls 2-20 years Cerebral Palsy Group 1* (solid), General Population (dashed)

Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'

Material data sheet. EOS MaragingSteel MS1. Description

Simulation for the Collapse of WTC after Aeroplane Impact

Out - Ecrano / White Charcoal

GCSE Exam Questions on Volume Question 1. (AQA June 2003 Intermediate Paper 2 Calculator OK) A large carton contains 4 litres of orange juice.

HAND TOOLS FOR PLASTIC STRAPPING

XI / PHYSICS FLUIDS IN MOTION 11/PA

PRELIMINARY BROCHURE. Uddeholm Corrax

information information

Standard Test Procedures Manual

PRO-VAC 150-LG-75 VACUUM BAGGING FILM For low temperature cure up to 120 C

Modular Access Floor for Data Center. From Rack to Row to Room to Building

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

epros DrainLiner Program

Puddle Flange. FRANK Puddle Flange

( PULSA AQUI )

Cable Trays Technical Instructions & Specifications

Mineral waterproof coating PCI Dichtschlämme

Lumin Scandinavia. Evoluce TWO 46. True Multitouch LCD 46 with 3D-sensing Technology

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

MEASUREMENT OF VISCOSITY OF LIQUIDS BY THE STOKE S METHOD

Transcription:

Technical Specifications BIO-BLOK 80 HD G Product: Type BIO-BLOK 80 HD G (80 m 2 /m 3 ). Produced by. Constructed of 8 x 8 net tubes that are subsequently welded Approx. 54 x 54 x 55 cm. 80 m 2 /m 3 in dry condition. Depending on the thickness of the biofilm, the accessible biological surface varies from 80 m 2 /m 3 to approx. 366 m 2 /m 3. : Approx. 70 % : Approx. 24 % Void percentage: Approx. 95 % Net weight: Approx. 60 kg/m 3 biofilm coating: Approx. 5 kg/m 3 Density: Approx. 0.93 gr./cm 3 Approx. 1,000 kg/m 2 (please ask our technical department). the vertical passages is: Inside approx. Ø 63 mm

Technical Specifications BIO-BLOK 100 Product: Type BIO-BLOK 100 (100 m 2 /m 3 ). Produced by. Constructed of 8 x 8 net tubes that are subsequently welded Approx. 54 x 54 x 55 cm. 100 m 2 /m 3 in dry condition. Depending on the thickness of the biofilm, the accessible biological surface varies from 100 m 2 /m 3 to approx. 336 m 2 /m 3. : Approx. 70 % : Approx. 22 % Void percentage: Approx. 90 % Net weight: Approx. 38 kg/m 3 biofilm coating: Approx. 62 kg/m 3 Approx. 1,000 kg/m 2 (please ask our technical department). the vertical passages is: Inside approx. Ø 65 mm

Technical Specifications BIO-BLOK 150 Product: Type BIO-BLOK 150 (150 m 2 /m 3 ). Produced by. Constructed of 10 x 10 net tubes that are subsequently welded Approx. 55 x 55 x 55 cm. 150 m 2 /m 3 in dry condition. Depending on the thickness of the biofilm, the accessible biological surface varies from 150 m 2 /m 3 to approx. 507 m 2 /m 3. : Approx. 74 % : Approx. 19 % Void percentage: Approx. 88 % Net weight: Approx. 51 kg/m 3 biofilm coating: Approx. 69 kg/m 3 Approx. 4,000 kg/m 2 (please ask our technical department). the vertical passages is: Inside approx. Ø 45 mm 15-08-2011

Technical Specifications BIO-BLOK 200 Product: Type BIO-BLOK 200 (200 m 2 /m 3 ). Produced by. Constructed of 10 x 10 net tubes that are subsequently welded Approx. 55 x 55 x 55 cm. 200 m 2 /m 3 in dry condition. Depending on the thickness of the biofilm, the accessible biological surface varies from 200 m 2 /m 3 to approx. 426 m 2 /m 3. : Approx. 64 % : Approx. 15 % Void percentage: Approx. 82 % Net weight: Approx. 60 kg/m 3 biofilm coating: Approx. 120 kg/m 3 Approx. 5,000 kg/m 2 (please ask our technical department). the vertical passages is: Inside approx. Ø 45 mm

Technical Specifications BIO-BLOK 300 Product: Type BIO-BLOK 300 (300 m 2 /m 3 ). Produced by. Constructed of 7 x 15 net tubes that are subsequently welded together in the sides of the tube so that the filter becomes a cubical Approx. 55.0 (+/- 1.0 cm) x 25 (+/- 0.5 cm) x 55 cm (+/- 0.5 cm). tubes) from 40 to 70cm. 300 m 2 /m 3 in dry condition. Depending on the thickness of the biofilm, the accessible biological surface varies from 300 m 2 /m 3 to approx. 560 m 2 /m 3. : Approx. 49% : Approx. 10% Void percentage: Approx. 83% Net weight: Approx. 100 kg/m 3 biofilm coating: Approx. 67 kg/m 3 Density: Approx. 0.6 gr./cm 3 Approx. 5,000 kg/m 2 (please ask our technical department). the vertical passages is: Inside approx. Ø 22 mm 09-01-2009