Lateral Connection Repair in main sewer pipes



Similar documents
Lateral Connection repair in main sewer pipes DIBt Z Z Z Z

epros DrainLiner Program

Rainwater going astray. EPROPOX FC30 epoxy resin system to be prepared for a rainy day

TRELLEBORG INDUSTRIAL SOLUTIONS. MtH practice Part 2 EXPERT AUDIENCE WAS PATENTLY CONVINCED IN MUNICH

Product catalogue, pipe and sewer cleaning systems

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX

Remote Head REMO ONE. Code Manual

Installation & Operation Manual. Type 1801 External Seahorse Pantograph Wiper. without Control System

2003 ACCORD - Automatic Transmission Removal

Monitoring of Natural Hazards With the ImpactSentinel Alarming System An Intelligent Solution

Introduction to Pressure Pipe Rehabilitation with CIPP

900 series. Flat panel Floor stands. The 900 series Flat panel Floor stands.

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Competition moves up to the test winner

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

exactly what is needed

Get the benefits of Norgren s unique range of Online services

Product catalogue, tank cleaning systems

Waste Collection Systems

Drain & Sewer. Cleaning. Drain and Sewer cleaning Fluid transfer solutions TRELLEBORG FLUID HANDLING SOLUTIONS

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

Cooling system components, removing and installing

5 axle Lowbed Semitrailer with Automatic Steering Model ST L3. (Lowbed length approx. 14,000 mm) Technical Specification no.

Assisted lift operated 2/2-way solenoid valves Type EV250B

KEG Sewer Cleaning Equipment for Experts

ARCHITECTURAL. FritsJurgens Pivot Door System Product Range Brochure

Operating instructions for Electrode sharpening machine WIG 4

Product catalogue, abrasive cutting

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

ALL YOUR DRAINAGE NEEDS. Tel:

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Pressure Pipe and Sewer Renovation

MONDOATHENS BASKETBALL SET (Reference PK110)

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Puddle Flange. FRANK Puddle Flange

SECTION NONREINFORCED CONCRETE SEWER PIPE

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

Saferand easierinstallation

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Adjustments for the Active Pneumatic Vibration Isolation Table during Final Installation (File version 6)

Coolflo Safe Touch Shower Mixing Valve ST20015CP

OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Agilent 4338B Milliohm Meter

UVDB empowered by Achilles

Bringing good things ahead

DIGIPASS Cradle Assembly instructions

Turbocharger system components, servicing

Machine needle shut-off nozzle type-a

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Front axle components, overview

Pneumatic tube systems

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

INSTALLATION OF INSITUFORM LINER

TÜV Middle East W.L.L. Welcome

Fiberstars Lighted Laminar Flow Fountain Installation Manual

- GFRP pipe liners - UV curing technology - TQM - Total Quality Management

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

swimming pool accessories

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

REPAIRS TO DAMAGED SEWERS

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

TRIMMING UNIT/DIAMOND MACHINE TST.13

GENERAL SPECIFICATIONS AND GUIDELINES FOR INSTALLATION MASTERLINER CURED-IN-PLACE PIPE SYSTEMS

DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES

Consumer acces.- special equipment

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

spinner Measurement & Calibration equipment for network analyzers

18. CARGO TROLLEYS, LIFTING TABLES, HYDRAULIC TABLE TRUCKS, HAND TROLLEYS

PORTLAND BES ADVANCES IN SEWER MAINTENANCE AND REPAIRS BY OPERATING MULTIPLE CIPP CREWS.

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Workshop Compressors CLASSIC Series

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Tube Control Measurement, Sorting Modular System for Glass Tube

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

Exceptional Accuracy and Durability for Tough Industrial Environments INDUSTRIAL FLOOR SCALES. VERTEX Industrial Floor Scales Heavy-Duty Design

MAN - MERCEDES - BENZ

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

Incubator with mechanical convection

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Systematic Sewer Repair

Installation Instructions

Machine needle shut-off nozzle type HP

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

Transcription:

Trelleborg PIPE SEALS Lateral Connection Repair in main sewer pipes epros DrainLCR-S

Introducing Trelleborg Pipe Seals Part of the wider Trelleborg Industrial Solutions Business Area of Trelleborg Group, Trelleborg Pipe Seals is a world leading supplier of new and rehabilitation sealing solutions for concrete and plastic pipes, manholes and connectors used for water, sewerage and drainage. With a global reach and a track record spanning more than half a century, we deliver continuous innovation to customers across the globe, with a logistics and sales network spanning Asia Pacific, Europe, Middle East, Africa, North America and South America. Comprising the most advanced polymer technology, the high performance level of our seals ensures fulfilment of the highest possible reliability standards. We will see you through from the beginning of your project right to the very end with the most advanced polymer technology and engineering expertise. Whether you need an entirely new system or your existing one needs maintenance, you can choose from a range of market-leading seals that offer: High quality Quick and easy installation Improved productivity Zero leakage Trelleborg Pipe Seals offer the highest reliability and performance standards, providing watertight solutions that protect not only your pipe cycle, but your reputation too. 2 3

epros DrainLCR-S How does it work Trelleborg Pipe Seals is among the leading specialist companies in innovative technologies for the upkeep of sewer systems. The brand name epros DrainSystems stands for 20 years of experience, continuous research and further development of technical systems for modern trenchless repair of pipelines in sewer systems, buildings and industries. The epros DrainLCR-S system is both a pipe repair device and a method for the lateral connection repair (house lateral connections) of main pipes in public infrastructure networks. It repairs and permanently seals main/lateral interfaces and lateral connections (DN 100 DN 200) by installing either a LCR-S hat profile or an LCR-S liner from the main pipe (DN 135 DN 600) up to a length of 600 mm. The LCR-S hat profile seals the main/lateral junction in the main line just with its rim. The LCRS liner in the main pipe is designed similar to a short liner and will at the same time repair a defined length of the lateral pipe. In both cases, the forming element is an inflatable pro-formed hose that serves the same function. This inflatable hose in the form of a cylinder (packer hose), is additionally equipped with another cylinder located at the mid-point (the lateral hose) at an angle of 45 or 90 to the axis of the packer. Prior to installation, this lateral hose together with resin-impregnated LCR-S Liner or LCR-S hat profile is re-inverted into the packer hose. Sucking out the complete air out of the packer hose and the branch hose generates a sort of vacuum, which allows to defend the repair material inside the packer hose (LCR-S Liner or LCR-S hat profile) from possible dislocation during the insertion into the pipe. This is usually performed by means of a push rod reel system, and in case of short distances and small pipe diameters with a pneumatic push-rod attached to the packer. In case of both applications precise determination of damaged area as well as the correct positioning of the packer are imperative. The following devices are used for these purposes: First, a camera is mounted on the packer. This camera helps to locate the junction of the house connection pipe to the main pipe. The packer is equipped with a telescopic wheel system and a rotary drive that enables the user to rotate it axially in the damaged area and so to locate the junction whilst the wheel systems braced inside the pipe maintain the axial position. The packer rod is featured by a lifting mechanism with a compressed air cylinder (pathfinder) pushing a sort of ring (the packer basket) into the main/ lateral junction area. This packer basket is located underneath the packer hose directly at the packer hose/ branch hose link and its lifting mechanism is controlled via an operator panel from outside the pipe. It is the function of the pathfinder to achieve the correct positioning inside the sewer pipe at the damaged lateral connection and to lift up the basket directly into the junction. The LCR-S Packer, prepared in this way, is then pushed into the damaged area. When the packer has reached its final position, the inflation process is started with the packer hose and after a given time delay continued with both, the lateral hose and liner, now inverting into the connection pipe whilst the lifting basket is driven back. The time-delayed inflation is controlled by means of a stiff cable, inserted and braked using a reeling box. When the lateral packer hose has been completely inverted, a clear acoustic signal is given to indicate that the inversion process successfully is finalized. After curing of the liner, the packer is blown off and removed from the repair area. Benefits at a glance Application area Mainline DN 130 DN 600 Lateral DN 100 DN 200 30 90 Portable modular system Light mobile unit, can be transported also in a small vehicle Value for money Low investment costs, because only packer sizes that are really needed must be purchased. Fast installation allows multiple installations per day User-friendly handling LCR packers can be converted into other sizes, according to your needs. This allows as much flexibility in application as possible. Our appropriate resin systems are designed to have both comfortable pot times and quick cure times as soon as the chemical reaction has been started. This helps to reduce time pressure, increases work security and leads to better product quality. Safe installation 1. Starting the inflation process is possible only after the LCR basket is locked in place. 2. Only a complete finalized inflation process triggers the acoustic signal. Clean Technology Trenchless technology. No voc s, no styrene, no environmental or health issues Quality and Sustainability No shrinkage. Glass reinforced hat profiles and liners ensure excellent mechanical properties and a good rehabilitation result with a long lifetime. 4 5

epros DrainLCR-S Functional principle * 3 Bringing the LCR-S packer into its final position Move back the packer until the packer basket engages with the lateral connection pipe (to be checked visually via camera and manually via the pull-in and retaining ropes). Make sure the Packer is centred in the lateral pipe. 1 Positioning of the LCR-S packer The LCR-S System allows to repair lateral connections with bends from 30 (from DN 100) to 90. A monitoring camera installed on the packer assists in the positioning process. Push or pull the LCR-S packer to the point of repair. Rotate the LCR-S Packer basket with the help of the control unit and the camera to align it with the lateral connection. 4 Inversion of the LCR-S hat profile/ liner into the lateral connection pipe Fill compressed air according to the prescription of the method statement into the Calibration Hose until the brim or liner is positively pressed against the main pipe. Maintain the specified air pressure constantly and start inverting in the liner. After the liner is fully inverted and pressed against the pipe wall the curing process has to start. The filling pressure must be maintained until the end of curing process. 2 Lifting the LCR-S packer basket Push the LCR-S Packer beyond the position of the lateral pipe to be repaired. Then lift the basket until it touches the pipe wall. To do so, set the operating lever of the LCR-S Control Unit to its up position. 5 Removing the LCR-S packer At the end of the curing process the LCR-S Packer is deflated and can be removed from the pipe *) This short introduction is just to show how the system basically works. All details about the method and the correct application of the LCR-S rehabilitation System are available in the method statement and technical data sheets only. 6 7

epros DrainLCR-S Technical components 8 1 Compressor, minimum 300 L / 8 bar / power generator 250 V / 50 Hz / 2,5 A 2 Compressed air hose 10 m 3 LCR-S control unit with monitor, incl. 60 m hose package and camera 4 LCR-S Cobra reel system, 100 m with flex adapter 5 LCR-S rotary drive 6 LCR-S wheel set 7 LCR-S packer 8 LCR-S camera 9

LCR-S Basic equipment Allen Key with T-Handle 8 mm LCR-S control unit (German)*LCR-S control unit (English)**Other languages available on request LCR-S Tripod stand set (two tripod stands, height-adjustable and demountable, galvanized) LCR-S Hose Reel with rotary feedthrough incl. camera cable and all supply lines LCR-S Packer Type 300 (Standard) Lateral connection repair length 280 mm LCR-S Packer Type 500 or Type 600 Lateral connection repair length 500 / 600 mm Data required for the packer: a) Lateral connection length b) Main pipe diameter (DN 135 DN 600) c) Lateral connection pipe diameter (DN100 DN200) d) Connection angle (45 or 90 ) Optionally (instead of Y manifold) The LCR packer must be equipped with the proper wheel set according to pipe dimensions. Wheel sets can be adjusted to various pipe dimensions. A wheel set is equipped with 2 wheel supports. If two or more LCR packers are used simultaneously, then more wheel sets must be used accordingly. The wheel sets are also necessary when used with a trolley. LCR-S wheel set DN 135 DN 250 incl. 40, 60, and 80 mm wheels LCR-S wheel set DN 300 DN 450 incl. 80 and 120 mm wheels LCR-S wheel set replacement unit (from DN 450 to DN 500/DN 600) 10 11

LCR-S Basic equipment LCR- Flexible fibre glass push rod (L 100 m / ø 11 mm ) on reel system (ø 0.90 m) equipped with a flexible plug for the packer connection LCR-Rotary Drive for exact long distance positioning, Also mountable on the LCR-Packer. With the Control-Unit the LCR-packer can be turned to the left and the right with a rotation of 360. LCR-S camera bracket set for camera assembly incl. assembly plate, camera assembly bracket and screws (DN 200 450). Fixing rods 40, 60, 80, 110 and 170 mm as well as extra assembly bracket for small diameters (DN 135 DN 150) = Alternatively instead of LCR-S reel system LCR-Air push-rods (red) with safety coupling and locking device 0.7 m 1.5 m 3.0 m LCR-Flex Adapter with Locking Device for LCR- Air Push Rods (red) and LCR-Fibre Glass Push Rod LCR-S camera bracket for the opposite side Necessary for the 45 LCR packer for application in directional flow Compressed air hose 10 m with SVS coupling Whistle set ref. Art. No. 000047400 (camera bracket for the opposite side) LCR-S rubber bands, e.g. for fixing the hat profile, 100 pcs. in bag Eye bolt for cable leading (optionally) Special binding wire Ø 0.65 mm on spindle Punching tool i To prevent the lack of an important item at the repair site at a crucial moment, we recommend a basic toolbox or a basic integration box for both the epros LCR systems. This will guarantee that you are always equipped with top-quality tools, materials and the proper accessories set, so you always everything you need on hand. All components can be purchased separately. More information on page 16 and the following pages. 12 13

Packer conversion articles Packer conversion and repair tool boxes LCR basic toolbox For details and article numbers pl. refer to system catalogue LCR repair set for calibration hose (in plastic systainer): Super glue (tube) LCR Basic Tool Box compl. Basic equipment for rehabilitation with epros LCR-S or epros LCR-B system used in connection with a particular supplementary kit All-purpose cleaner (bottle) Plastic box (Systainer type IV) LCR silicone patches (190 x 280 mm) Dimensions approx. 600 x 400 x 240 mm Silicone glue Tube with roll-up enhancing agent and spray tip) Cleaning rag (380 x 380 mm) LCR-S supplementary kit for the LCR basic toolbox LCR-S DrainCali 300 (calibration hose) Lateral connection length 280 mm (Standard) DN 135/100 600/200 mm; 45 or 90 This kit contains LCR-S specific small spare parts, e.g. couplings, screws, seals, air hoses and a combination wrench set. LCR-S calibration hose DrainCali 600 (Packer retrofitting necessary) LCR-S packer baskets Necessary information: a) Main pipe diameter (DN 135 DN 600) b) Secondary pipe diameter (DN 100 DN 200) c) Connection angle (45 or 90 ) Easy Service for you! Integration box for LCR packer conversion Now even easier: With only one basic toolbox or a basic integration box for both epros LCR systems you have the best equipment and the right supplementary system set. You can have on hand everything you need on the work site! LCR Basic Tool Box compl. (Basic equipment for packer conversion from epros LCR-S and epros LCR-B system used in connection with respective supplementary kit) Plastic box (Systainer type IV) Dimensions approx. 600 x 400 x 240 mm LCR-S lifting rods DN 135 DN 150 DN 200 / 225 DN 250 DN 300 / 350 DN 400 / 450 DN 500 / 550 / 600 DN dimensions refer to the main pipe diameter LCR-S supplementary kit for LCR integration box Spare parts especially for the LCR-S Packer conversion requirements 14 15

Zero Leakage Total performence 16 17

Approved Resin Systems for the LCR-S method epros Silicate Resin Systems (ambient cure) epros epoxy Resin Systems (hot cure) Silicate Resin Systems Comp. A (Hardener) + B (Resin) Mixing ratio 1:2 (Litre) epros SilicateResin Type W1 Pot life 15 min. (20 C) Cure time 115 min. (15 C) epros SilicateResin Type S1 Pot life 32 min (20 C) Cure time 260 min (15 C) EPROPOX HC60 Pot life 60 min. (25 C) Cure time 60 min. (60 C hot water) EPROPOX HC120 Pot life 120 min (25 C) Cure time 90 min ( 60 C hot water) Can Sizes epros SilicateResin type W1 epros SilicateResin type S1 26 kg (=Comp. B) epros Hardener 16 kg (=Comp. A) Drum Sizes epros SilicateResin type W1 epros SilicateResin type S1 250 kg (=Comp. B) epros Hardener 300 kg (=Comp. A) epoxy resin systems Comp. A (Resin) + B (Hardener) Mixing ratio 100:33 (Litre) EPROPOX FC15* Pot life 15 min. (25 C) Cure time 120 min. (20 C) EPROPOX FC30 Pot life 30 min (25 C) Cure time 240 min (20 C) 1. For more technical details pl. refer to Technical Data Sheet 2. For Package sizes and Art. Numbers or prices pl. refer to price catalogue *) no technical approval 18 19

Self-sealing LCR hat profiles and liner For your notes Any questions LCR-S Hat Profiles LCR-S hat profile 300* LCR-S hat profile 600* The material of the hat profile consists of a mixture of glass fibre (85%) and plastic fibre mat (15%). LCR-hat profiles are covered with PVC foil, the brim is reinforced. DN 100, 125, 150, 200, 225, 250, 45 or 90 Wall thickness 3 5 mm according to version *) Lateral length 280 mm (type 300) For type 600 (lateral length 600 mm) packer retrofitting is necessary LCR-Liner - multidimensional! Only 3 sizes for main sewer diameter (DN 100/200 DN 100/300 DN 350/600) Lateral connection DN 50 DN 250 /45 or 90. High quality material as described above. Why not to use your existing LCR control unit for high-quality impregnation of LCRliner and LCR hat profiles? Please use the vacuum function of the LCR control unit for this purpose! We supply you with the details about the method how to get a quick, bubble-free and high-quality impregnation. 20 21

FURTHER INFORMATION DIBt Approvals No. Z-42.3-375 epros DrainLiner Method DN 100 DN 400 with epoxy resin system EPROPOX HC60 Including the LCR-S Method with epoxy resin system EPROPOX HC60 and Silicate Resin Systems S1, W1, W01 No. Z-42.3-466 epros DrainLiner Method DN 100 DN 250 with epoxy resin systems EPROPOX FC15 / FC30 Including the LCR-S Method with epoxy resin systems EPROPOX FC15 / FC30 and Silicate Resin System S1, W1, W01 Trelleborg around the world COUNTRIES WITH OWN OFFICES COUNTRIES WITH DISTRIBUTORS No. Z-42.3-468 epros DrainLiner Method DN 100 DN 600 with epoxy resin system EPROPOX HC120 Including the LCR-S Method with epoxy resin systems EPROPOX FC15 / FC30 and Silicate Resin System S1, W1, W01 No. Z-42.3-483 epros DrainLiner Method DN 100 DN 1000 with epoxy resin system EPROPOX HC2640 Including the LCR-S Method with epoxy resin systems EPROPOX FC15 / FC30 with epoxy resin system EPROPOX HC60 and Silicate Resin System S1, W1, W01 USA Australia France New Zealand Germany Belgium Great Britain Norway Video Link: http://www.trelleborg.com/en/epros/product-range/epros-regdrainlcr-s/ Croatia Hong Kong Portugal LCR-S System Catalogue Czech Republic Italy Saudi Arabia Price Catalogue Denmark Malaysia Spain Technical Data Sheets Finland Netherlands Sweden Method Statement 22 23

Trelleborg is a world leader in engineered polymer solutions that seal, damp and protect critical applications in demanding environments. Our innovative engineered solutions accelerate performance for customers in a sustainable way. The Trelleborg Group has local presence in over 40 countries around the world. Trelleborg Pipe Seals is a world leading supplier of new and rehabilitation sealing solutions for concrete and plastic pipes and manholes used for water, sewerage and drainage. We deliver continuous innovation to customers across the globe, with a logistics and sales network. Comprising the most advanced polymer technology, our high performance seals ensure fulfillment of the highest possible reliability standards. www.trelleborg.com/pipe-seals facebook.com/pages/trelleborg-pipe-seals-duisburg twitter.com/pipeseals youtube.com/user/eprosdrainsystems D EN Vertrieb Deutschland/Europa, Trelleborg Pipe Seals Duisburg GmbH, Dr.-Alfred-Herrhausen-Allee 36, 47228 Duisburg, Germany, Phone: +49 2065 999 0, Fax: +49 2065 999 111 Pipeline Rehabilitation Products, North America, c/o Trelleborg Pipe Seals Milford Inc, 250 Elm Street Milford, New Hampshire 03055, USA, Tel: +1 603 673 8680, Fax: +1 603 673 7271