COMPRESSED AIR SYSTEM AUDIT SOFTWARE



Similar documents
Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Appendix C. Minimum Equipment Efficiency Standards

USING KPI S FOR PEAK EFFICIENCY

Centrifugal Fans and Pumps are sized to meet the maximum

Compressed Air Systems

How To Save Energy On A Power Plant

ENERGY AUDIT REPORT MINIMUM REQUIREMENTS

Energy Efficiency Best Practice Guide Compressed Air Systems

Why and How we Use Capacity Control

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Unit 24: Applications of Pneumatics and Hydraulics

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

DATA COLLECTION AND PUMP ENERGY SAVING OPPORTUNITIES. Presented By: Rick Rumsey, P.E.

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

BOEING CANADA WINNIPEG RECOGNIZED FOR COMPRESSED AIR PROJECT

How to Choose the Right Air Compressor

Screw Compressors 11-22kW

PC1130 Electric Air Compressor

Printing and Publishing Energy Savings Guide

Unit 24: Applications of Pneumatics and Hydraulics

COUNTERBALANCE VALVES

Chapter 3.4: HVAC & Refrigeration System

Unit 24: Applications of Pneumatics and Hydraulics

PC1131 Electric Air Compressor

Pressurized Water Reactor B&W Technology Crosstraining Course Manual. Chapter 9.0. Integrated Control System

an EnPro Industries company

8. ENERGY PERFORMANCE ASSESSMENT OF COMPRESSORS 8.1 Introduction

ROTARY SCREW COMPRESSOR. RMD kw

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

AIR POWER GLOSSARY. Air Outlet/Hose Connection An air outlet/hose connection is a 1-1/4 NPT thread fitting where the air hose attaches.

Appendices. Appendix A This appendix is a glossary defining terms used in the compressed air industry.

Choosing Between Electromechanical and Fluid Power Linear Actuators in Industrial Systems Design

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Development and testing of a multi-type air conditioner without using AC inverters

ENERGY RETROFIT PROGRAM

Pressure Relief and Regulating Valves

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

CHAPTER 8. PRIME MOVERS OF ENERGY

The Best Technology for the Application. Educating the Specifier on Medical Air & Medical Vacuum Systems

Throttle Body Fuel Injection

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Heat Recovery and Compressed Air Systems

Example. Fluid Power. Circuits

Product Data Bulletin

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

Energy Audits Waste Water Treatment Plants

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Performance Analysis of a. for a Diesel Engine

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Oil Injection Rotary Screw Compressors Contributing to Environmental Protection and Energy Conservation

LLC "VT Technology" INTRODUCTION OF SCREW ROTOR STEAM ENGINES AT THERMAL POWER GENERATION FACILITIES. St. Petersburg, Russia 2015

Chapters 7. Performance Comparison of CI and SI Engines. Performance Comparison of CI and SI Engines con t. SI vs CI Performance Comparison

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

Application Information

PUMPS TYPE OF PUMP PRESSURE/FLOW RATING CHARACTERISTICS. Centrifugal Low Pressure/High Flow Flow changes when

Centrifugal Water Chillers. Scott Meyerkord

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Hydraulic Control Technology for Wind Turbine Generators

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Chapter 3.5: Fans and Blowers

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Introduction to Process Control Actuators

Inverter and programmable controls in heat pump applications

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

REGULATING VALVE APPLICATIONS

CITY OF TORONTO WATER LOSS STUDY & PRESSURE MANAGEMENT PILOT

Unit 24: Applications of Pneumatics and Hydraulics

Optimization of Water - Cooled Chiller Cooling Tower Combinations

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Description of a Basic Vacuum System

Quiz On Information Learned From Chapter 1

Unidrive M Energy Savings

Model-based Parameter Optimization of an Engine Control Unit using Genetic Algorithms

Medical Air Systems: Scroll

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

OPTIMAL DISPATCH OF POWER GENERATION SOFTWARE PACKAGE USING MATLAB

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

The Secret of Hydraulic Schematics. BTPHydraulics

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Energy Audits. Good energy management begins with an energy audit

Optimization of Industrial Refrigeration Plants: Including a Case Study at Stonyfield Farm Yogurt

Xcel Business Customers: Program and Rebate Summary

G234X-55 Conventional Gas Boiler

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

Air Conditioning Clinic

The Benefits of Management Information Systems to the Professional Practice

Creating Efficient HVAC Systems

Basic Technology Series

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

8. Refrigeration. 4. Liquid. Refrigerant. 4. Liquid Refrigerant. Figure 8.1 Refrigeration system layout (single stage)

Commissioning - Construction Documents (Page 1 of 6)

KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE

Transcription:

COMPRESSED AIR SYSTEM AUDIT SOFTWARE Eric G. Bessey, Oregon State University Richard D. McGill, Oregon State University George M. Wheeler, Oregon State University Karl Vischer, Bonneville Power Administration INTRODUCTION Air compressors are a significant industrial energy user. Based on a survey of energy audit reports from 125 northwest plants, air compressors account for roughly % of total plant energy use. Air compression is inherently inefficient with up to 95% of compressor power dissipated as heat. Thus, even minor improvements in system operation, control strategies, and efficiency can yield large energy savings. Many industrial plants have significant air leaks, or inappropriate uses of compressed air. Because the cost to compress air is high, reducing compressed air losses to system leaks and inappropriate uses of air can also produce energy and cost savings. Since air compressors often are encountered in industrial energy audits, one goal of this project is to develop a software analysis tool. A spreadsheet-based program was developed to model compressed air system operation and estimate energy savings for six typical Energy Efficiency Measures (EEMs). The program can model part load system operation with up to three compressors operating simultaneously and independent operating schedules. The model was developed in conjunction with an audit methodology and is intended to enable energy auditors to simulate both existing and modified system operation and evaluate the EEMs. Thus, the program title is: Justify Air Operation and Maintenance (JAirOAM, also known as "Jerome"). Ten audits are currently being conducted to develop and validate the model COMPRESSOR CHARACfERISTICS Compressed air systems often have multiple compressors with different operating schedules and control strategies. There are three common types of compressors: rotary screw.. reciprocating, and centrifugal. Since centrifugal compressors are used primarily in I e plants with high air use, they were not specifically included in this project. To assist industrial energy auditors, Jerome should be able to model each type ofsystem that might be encountered. There are three control strategies used to match part load compressor output to system requirements: modulation, flow I no flow, and low-unload. Compressor part load operation is modeled using normalized power versus air flow profiles. Modulation Control There are two types of modulation: throttle and turn or poppet valves. Air flow is controlled by the position of the throttle or turn valve, or the number of poppet valves open, which proportional to discharge pressure within the Proportional Modulation Pressure Range (PR). The PR is the difference between the Full Load Discharge Pressure (pmin) and the No Load Discharge Pressure (PMAX) and is generally fixed for a given compressor. In general, when discharge pressure is low, the throttle is wide open, or the turn or poppet valves are closed, resulting in full air delivery.. If air flow requirements are less than the capacity of the compressor, discharge pressure will increase until PMIN is reached. At this point, the throttle will begin to close, or turn or poppet valves will begin to open, reducing air flow from the compressor. Modulation continues until compressor air flow matches plant air 343

requirements and discharge pressure stabilizes. If no air is required from the compressor (for example, another compressor can meet air flow requirements), discharge pressure will continue to increase and modulation will continue until no air flows from the compressor. PMAX is defined as the discharge pressure at which the throttle finally closes completely, the tucn valve opens completely, or all poppet valves are open. If pressure drops below PMAX, the throttle will open, or the tum or poppet valves will close. Throttling is a fonn of inlet modulation accomplished by a butterfly or slide valve, and is typically found on rotary screw compressors. Air flow is reduced by creating a partial vacuum at the compressor inlet by closing a butterfly or slide valve. The result of this control strategy is a linear reduction in power with air flowe Part load performance will fall on a straight line drawn between the full load and no load operating points, as illustrated in Figure 1. 0...: r &. 80." 70! 60 =: SO 40!... 30 r 20 e g. 0 0 20 Throttle Control 30 40 50 60 70 Air F1ow( capacity) Figure Performance Profile for Throttle Control 80 0 0 I:' 80 l 70." J 60 1fL-""""'--- Turn or Poppet Valve Control SO no load G 40 30... 20! O-t--+-+--+--ofi-t----Il---il---otl---f...-..+...-+---B----+---t--a--+--+--+--+--t o 20 30 40 50 60 70 80 0 Air Flow (% capacity) Turn and Poppet Valves are the other fonns of modulation used on rotary screw compressors. As air requirements decrease, the turn valve rotates, allowing intake air to escape to atmospheric pressure through ports in the compression chamber walls, shortening the effective rotor length. The volumetric compression ratio and air flow are reduced, resulting in a quadratic reduction ofpower with air flow (Figure 2). Similarly, poppet valves open to allow intake air to escape, reducing air flow. Figure 20 Performance Profile for Tum or Poppet Valve Control Flow I No Flow Control The three types of flow I no flow controls are: load-unload, on-off, and multi-step. d UnIoad controls on rotary screw and Load-unload Control reciprocating compressors allow the 0. compressor to operate at two points: fully "i:' loaded and unloaded. The compressor 80 i operates at full load until the system reaches "t:.' 70 '/Illll 60 'l8ll' the maximum set pressure (PMAX) at which time the compressor unloads. An unloading a 50 40 valve at the compressor discharge vents the r. 30... oil separator and sump to a lower pressure. f 20 e no load No modulation occurs with this strategy. The 0 compressor reloads when system pressure drops to the minimum set pressure (PMIN). AirFlow(% capacity) No load power is reduced because the Figure 3 Performance Profile for load-unload Control.. fu II load 0 20 30 40 SO 60 70 80 0 344

compressor discharge pressure is less than system pressure. Average power is linear with average air flow between full and no-load (Figure 3). The dashed lines indicate the compressor never actually operates between full load and no load. 0 i l 80 ] SO 40 30 20. til (fp no load On-off Control 20 30 40 50 60 70 Air Flow (% capacity) - -... full load fi$ OW--I--f--ll--lo--l--I--I--I---I---I--f--ll--+--+o--+--+--+-+--I--t o 80 0 On-Off control is similar to load-unload control and is found primarily on reciprocating compressors. The compressor operates at full load until PMAX is reached. The motor then turns off until system pressure drops to PMIN, at which time the compressor turns back on. This strategy is also modeled as a linear reduction in average power with average air flow (Figure 4). Figure 4.. Perfonnance Profile for On-off Control Multi..step control is found only on reciprocating compressors. Reciprocating compressors with multiple pistons reduce capacity by opening intake valves or chambers" This type of control is not a true flow I no flow control type. However, the part load performance of a compressor with multi-step control is modeled the same as a compressor with load-unload control with a linear reduction in power with flow. The compressor operates at fun load') no load, and one or more intermediate loads (Figure 5). 0 80 70 60 50 40 30 20 Figure 5 qj$ no load ""r step 2 20 Milti -s tep Control 30 40 50 60 70 Air flow(% capacity) 11$& step 4 full load O-+--...--+-.--+---I--+<--I-I-+--I---+--+---+---I--I---+-+---I---t---I--... o Performance Profile for Multi-step Control 80 0 Low0 Unioad Control This control strategy is a combination of inlet modulation and load-unload controls and is found only on rotary screw type compressors. Modulation may be either throttle, turn or poppet valves. Compressors operate at full load until PMAX is reached, then begin to modulate to match system air requirements. If air requirements are below the unload point, the compressor will unload (Figures 6 and 7). Reloading occurs when system pressure drops to PMIN. The unload point may be adjustable or permanently set by the manufacturer. If the unload point is set at 0% of capacity, the control behaves as load-unload control 345

0 i 80 "e 70 j 60... 50 ;f 40 30 20 \$.. no load Low-unload Control unload _ ". full load O-l-1I-+-I--I-I---I--+--iI-+-+-+--+-+--+-I-t--+-+-+--1 o 20 30 40 50 60 70 80 0 Air Flow (% capacity) Figure 60 Performance Profile for Throttle Modulation and Low-unload Control 0 I:' ; 80 8. 70 ;e 40 30 til 20 gf Figure 74& Low..unload Control no load unload OI--i--4--J-I--+--I-+-+--I--l!-+-+-+--I-I-+-f o 20 30 40 50 60 70 80 0 Air Flow (% capacity) Performance Profile for Turn or Poppet Valve Modulation and Low-unload Control Compressors that unload often have a timer that turns offa compressor after being unloaded for a specified amount of time, such as 15 minutes.. This minimizes the number ofmotor starts.. Operating Pressure Ranges The pressure range is important when staging multiple compressors.. The PR dictates which compressors will be in lead, second, and third positions.. Following are examples of three compressors with different PR configurations.. The compressors in Figure 8 have nonoverlapping PRs, resulting in nonoverlapping, staged operation; the compressors in Figure 9 have overlapping but different PRs, resulting in overlapping, staged operation; the compressors Figure have identical PRs, resulting in simultaneous modulation or cycling.. For modulating compressors, system pressure remains constant for an air flow requirement.. An air flow requirement can be met by finding a pressure where the sum of each compressor's contributions matches the system airrequirement Compressors with multi-step or low-unload control are modeled the same way.. Nonoverlapping, Staged Compressor Operation 0...---...---o-tIIIIIIII 80 lead. 70 a 60 "-"" 50 40 fi: 30!oM :< 20 O-t-----t--""i---t-...-lI---i---tllllIII--...---lfm-- 0 1 2 3 4 5 6 7 8 0 1 Discharge Pressure (p ig) Owrlapping, Staged Compressor Operation 0 iiiiiiiir-..---tii 80 q 70 B 60 --- 40 &: 30 lead bo :< 20 50 O-l---+---I----t----:IIII---llllil-o--llll---t- 0 1 2 3 4 5 6 7 Discharge Pressure (psig) 8@ Compressors with Staged PRs figure 9$ Compressors with Overlapping, Staged PRs 346

Parallel Compressor Operation 0...-----liliiii 80 l 70 5 60 50 40 all comps - 30 :< 20 o I 0 1 2 3 4 5 6 7 8 9 1 Discharge Pressure (psig) Compressors with load-unload or on-off control stage similar to modulating compressors, but system pressure changes as compressors cycle. Air flow requirements that can be met by the lead compressor alone will leave the second and third compressors unloaded. The lead compressor will cycle. This is because system pressure will never drop to the other compressors' minimum pressure. If air flow requirements increase, system pressure will drop to the second compressor's minimum pressure, and it will reload. The second compressor will cycle and the lead will remain at full load. The compressors in Figure have identical PRs, resulting in simultaneous modulation. All compressors will cycle simultaneously. Figure. Compressors with Identical PRs As an example of how staging affects compressor operation, consider an air flow requirement of 150 acfm. The available compressed air system includes three compressors of 0 acfm capacity each. Table 1 shows how the required air flow is distributed among the compressor based on their control strategies and PRs. Refer to Figures 8, 9, and for pressure range configurations. Air Flow Distribution Pressure Range System Confi2UratioD (psi!) modulation,.. ing staged 5.5.....,. " 16... :. -'II,. Pressure Lead Compressor 2nd Compressor 3rd Compressor (acrm) (acrm) (acrm) 0 50 o 3.5 83.3 50 16.7 l()i.,5 50 50 50 Ait-f1owRequirement of 150 acfm for Different Control Strategies and Pressure Control strategies thattum off unneeded compressors are most efficient. MODEL Inputs Data collection methods range from simple to complex, depending on equipment available and desired accuracy. For example, compressor operation can be estimated, developed from an observed capacity gauge or amperage readings at selected operating conditions, or taken from weeks or months of data logger recordings of air flow, power, and pressure 347

Manufacturers' data is entered. Jerome needs to know numbers and types of compressors and controls that comprise the compressed air system. Jerome accepts up to three compressors of either rotary screw or reciprocating type. Manufacturerts data entered into Jerome include:.. manufacturer and model compressor type motor horsepower, rpm, voltage, and full load amps.. override motor efficiency and power factor.. air flow capacity rated full load discharge pressure full load compressor brake horsepower at rated full load pressure control strategy no load power expressed as a percentage offull load power A database of several manufacturers" compressors is included. Given the manufacturer and model of a compressor, Jerome looks up the remaining data and enters it automatically in the appropriate cells. Actual compressor operating conditions are entered. Jerome accepts compressor inlet conditions and corrects power and capacities for actual inlet conditions. Measured power can be entered for each operating point necessary to define the performance profile (such as full load and no load power). PMIN and the PR are entered for each compressor. If a compressor is equipped with low-unload controls, the unload point is entered. Jerome constructs performance profiles for each compressor. Calculated power may be compared to measured power. Typical daytypes are used to model plant air use. A daytype is a 24 hour period representing a typical operating day, such as a production weekday.. maintenance day.. or weekend day 0 Jerome accepts up to four daytypes and an annual schedule of occurrences for each daytype Hourly averages of air flow or power are entered for each compressor and daytype Jerome uses compressor perfonnance profiles to calculate hourly 0,...,... '"(3 «t 80 Q,. fl 70 E.! 60 (I.) 50 40... 30 Q 20 bi :< 0 System Air Flow Profile e ee : 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time ofday Figure llel System Air Flow Profile for a Weekday air flow averages if power was entered or hourly power averages if air flow was entered. System air flow and power profiles are created for each daytype. To create system air flow profiles, each compressor"s air flow is weighted by its capacity compared to system capacity for each hour of each dnytype. For example: a 200 acfm compressor operating at 25% ofcapacity (50 acfm) and a 0 acfm compressor operating at 0% ofcapacity (0 acfm) would have a system air flow of 50% of system capacity [(50 + 0)/(200 + 0)]0 Power for each compressor is added for each hour to create system power profiles. Examples ofsystem air flow and power profiles for a daytype are shown in Figures 11 and 12 respectively. 348

System PO\\er Profile 450-1-------- 400-+---...- 350 ';:' 300 e» 250 cf E 200 150 CI:) 0 50 o I I I I 1 2 3 4 S 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ThneofDay Jerome constructs compressor operating schedules for each daytype" If no air flow (0% of capacity) is entered, Jerome assumes the compressor is turned off that hour unless tbis is overridden by the operating scheduled. If the compressors are controlled by an automatic sequencer, the sequence schedule is entered for each daytype. Figure 12. System Power Profile for a Weekday Annual Air Flow and Power Profiles Each daytype is multiplied by the annual days of occurrence to create annual system air flow and power duration profiles (Figure 13). Finally, to simplify calculations and results presentation, air flows are put into % capacity bins$ Jerome then calculates average power for each bin and annual energy use by multiplying each power bin by its corresponding number ofannual operating hours. Energy Efficiency Measures Jerome implements each EEM interactively in the following order. The biggest savings are usually found by reducing leaks't installing an automatic sequencer, and reducing run time.. 1" Reduce Air Leaks is implemented first. The user enters a fixed flow reduction, representing a reduction in leaks.. A typical leak load target is %-30%, depending on plant conditions. Jerome subtracts this amount from each air flow bin in the annual air flow profile, and a new annual air flow is created" Figure illustrates a proposed annual system air flow profile and air flow reduction. B 0 y a. 80 e fa 70 QJ 60 iii.) 50 40 it 30 fi: 20 s- =< 0 0 Annual S y8 tern Air Flow Pronle pro rue reduction mproposed profile 20 30 40 50 60 70 80 0 % Operating Time Figure 1311 Proposed and Reduction of Annual Air Flow 2. Manual Staging allows pressure ranges to be altered. The user enters proposed PMINs for modulating, lowand multi.,.step controls., or proposed minimum and maximum pressures for load-unload and on-off controls This allows compressor with the poorest part load efficiency to operate at full load and the compressor with the best part load efficiency to pick up the slack. 349

3. Unloading Controls are added to selected compressors. No load power is significantly reduced, thereby improving part load performance. Figure 14 compares modulation to load-unload control for different operating points. Power savings is the difference between modulating power and average load-unload power. An automatic shutdown time can be included in unloading control paclcagesthatwill turn off compressors that have beeniunloaded for a specified length of time. This EEM is implemented after compressors have been staged. Modulation VSo wad-unload --;:-0 ; 8. 80 "e 70 60 50 40 ';:' 30 20 If O-+-t--+-+-+-ll-+-I--I--ir-+-I--I--t-l--+-+-+--+--+-t o 20 30 40 50 60 70 80 0 Air Flow (% capacity) Figure 140 Modulation vs. Load-Unload Performance Profile 4" Automatic Sequencing allows the user to specify a compressor sequence (specify lead, second, and third compressors) for each daytype and hour. Unloading controls are automatically added to compressors that don't have them. Individual compressor pressure ranges are no longer relevant since compressor sequence is specified by the user. 5$ Reduce System Pressure allows the user to reduce system pressure by a specified amount. Full load power for each compressor is reduced by one half of a percent per psi of pressure reduction. 6. Reduce Run Time allows the user to turn off unneeded compressors by changing compressor operating schedules. Power reduction is based on compressor power at the particular unneeded times after implementing previous EEMs. Most savings are for compressors operating at no load.. which is significant (approximately 65%) for modulated compressors Calculations Next, compressor power to meet the proposed air flow profile must be calculated. Air flow must be apportioned to the compressors based on control strategies and/or sequencing. Once an air flow is determined for a compressor, power is easily calculated based on its proposed performance profile. For load-unload, on-off, and automatic sequencing controls, air flow is supplied by each compressor, depending on pressure ranges or sequence. For example, an air flow requirement of350 acfm supplied by a system ofa 0 acfm compressor and a 300 acfm compressor 300 acfm would go to the 300 acfm compressor and the remaining 50 acfm would go to the 0 acfm compressor, if pressures are set properly or compressor sequence is specified. Systems with modulating, low-unload compressors (unload point set less than 0% capacity), and multi-step controls present a greater challenge. Pressure range and discharge pressure dictate how much air each compressor will dehver$ Jerome uses a numerical solution routine built into the spreadsheet program to determine how much air each compressor must supply to meet a required air flow. Jerome guesses a discharge pressure and calculates air flow for each operating compressore Jerome compares the sum with the required air flow. Discharge pressure is corrected and a new air flow is calculated and checked. Corrections are made until air flow matches required air flow within 0.5%0 This is done for each required air flow in the proposed air flow profile. Savings Power reduction is calculated as existing minus proposed power for each EEM. Demand charge savings is based on power reduction during the peak demand period. Energy savings are calculated for each EEM by multiplying power reduction by operating time for each bin. A summary table presents au power, energy, and cost savings.. Cost savings include demand charge and energy cost savings. 350

RESULTS Jerome produces results in graphical and tabular form for each compressed air system audit. from Jerome are: The three outputs Graphs ofindividual compressor and system performance profiles, and daytype power and air flow profiles (I Existing and proposed operating conditions tables for each EEM.. Savings summary table ofall EEMs Graphs. The figures shown in the Energy Efficiency Measures section are examples of performance, power, and air flow profiles from an audit of a plant with two twin screw compressors. Both compressors had inlet butterfly valve modulation controls. Jerome creates performance profiles for each compressor, using relationships defmed in the compressor characteristics section. Graphs of hourly power and air flow profiles are created for each daytype from measured audit data. Proposed compressor performance profiles are created for any modifications to compressor performance, such as adding unloading controls. Operating Conditions Tableo For each EEM recommended, Jerome creates a three part table that shows: existing conditions, proposed conditions, and demand, energy and cost savings for proposed conditions (Table 2). The first section of Table 2 shows existing system operation, while the second section shows proposed operating conditions after implementation. The third section shows demand, energy, and cost savings. The tables were taken from the Reduce Air Leaks EEM recommended for the same plant. Severa] modifications to system operation can be seen in Table 2. Proposed system leak load was reduced from 40.5 percent of the existing system capacity (2,500 acfm), to 30.4 percent of the proposed system capacity (1,000 acfm)e System capacity was reduced because it was recommended that one compressor be turned off. A second reduction in air use from eliminating inappropriate uses (330 acfm) can be seen during production periods 3 through 8. System power and energy use were also significantly reduced. Because one compressor was turned off, fun load power was reduced from 421.5 kw to 175.5 kw.. A majority of the savings resulted from shutting off the compressor. Power reduction is calculated as existing minus proposed power for each EEM. Energy savings are calculated for each EEM by multiplying power reduction by operating time for each production level (bin). Summary Tablee Jerome produces a Savings Summary table that presents power, energy and cost savings for all recommendations.. Cost savings include demand and energy costs savings. Table 3 shows the energy and cost savings estimated by Jerome for implementation of the three EEMs recommended during the audit used for the graphics and operating conditions examples. Note that operation and maintenance measures in compressed air systems represent a significant opportunity for savings with attractive economic returns. Savins Summar I Table Demand Charge: $4.35/kW-mo Energy Charge: $0.03327 / kwh E EEM Demand Energy Percent Cost Implemen- Payback # Description (kw) (kwh) Savings * Savings tation Cost Years 1 Reduce Leaks 246.0 1,600,438 59.3% $63,461 $24,655 0.4 2 Unloading Controls 0.9 250,449 9.3% $8,369 $1,200 0.1 3 Reduce Run Time 0.0 70,516 2.6% $2,346 $200 0.1 mum Savings 246.9 1,921,403 71.2% $74,157 $6,323 0..2 * Percent oftotal compressed air system annual energy use Table 3. Savings Summary Table 351

Existing Conditions Operating Conditions AirAow Power Power Operation Energy (%C.) ('lops) (kw) (hours) (kwh) no load 0% 60.3% 274.6 0 0 leak load 40.5% 53.4% 243.0 0 0 compressors off 0% 0% 0.0 395 0 non-production 40.7% 53.4% 243.3 1,500 364,999 production (1) 45.8% 55.5% 252.9 231 59,1 (2) 51.6% 80.8% 367.8 395 145,226 (3) 57.2% 83.0% 377.9 711 268,573 (4) 62.2% 85.0% 386.9 1,895 733,188 (5) 67.9% 87.2% 397.2 869 344,989 (6) 72.3% 89.0% 405.3 7 320,007 (7) 78.0% 91.3% 415.5 553 229,679 (8) 81.3% 92.6% 421.5 553 232,956 full load 0% 0% 455.3 0 0 Total 92.6% 421.5 7,896 2,699,518 Proposed Conditions Operating Conditions Air Flow Power Power Operation Energy (%C) (%P) (kw) (hours) (kwh) no load 0% 60.9% 7.3 0 0 leak load 30.4% 72.8% 128.3 0 0 compressor off 0% 0% 0.0 395 0 non-production 30.8% 72.9% 128.6 1,500 192,885 production (1) 43.5% 77.9% 137.3 237 32,534 (2) 58.0% 83.6% 147.3 395 58,163 (3) 39.0% 76.1% 134.2 711 95,368 (4) 51.3% 81.0% 142.7 1,895 270,419 (5) 65.5% 86.5% 152.5 869 132,420 (6) 76.6%.9% 160.1 7 126,429 (1).7% 96.4% 169.8 553 93,878 (8) 98.9% 99.6% 175.5 553 96,984 fuld load 0% 0% 176.2 0 0 Total 99.6% 175.5 7,896 1,099,079 Savings Summary Demand Char2e: $3.46/kW-mo. Energy Charge: $0.03327 /kwh Air Use Demand Demand Operation Energy Energy Cost (acfm) (kw) ($) (hours) (kwh) ($) Savings compressors off 0 0.0 395 $0 $0 non...production 704 114.7 1,500 172,114 $5,726 $5,726 production (1) 704 115.5 237 27,367 $911 $911 (2) 704 220.5 395 87,063 $2,897 $2,897 (3) 1,034 243.7 711 173,205 $5,763 $5,763 (4) 1,034 244.2 1,895 462,768 $15,396 $15,396 (5) 1,034 244.7 869 212,569 $7,072 $7,072 (6) 1,034 245.2 7 193,578 $6,440 $6,440 (7) 1,034 245.7 553 135,801 $4,518 $4,518 (8) 1,034 246.0 $,214 553 135,972 $4,524 $14,738 Total 1,034 246.0 $,214 7,896 1,600,438 $53,247 $63,461 Table 20 Existing Conditions, Proposed Conditions, and Energy and Cost Savings 352

CONCLUSIONS An automated spreadsheet-based program, Jerome, was developed that can model existing and proposed operation ofindustrial compressed air systems. Some ofthe modeling capabilities ofjerome include: multiple compressor systems (up to three compressors operating simultaneously).. common control strategies.. rotary screw and reciprocating compressor types.. staging and sequencing ofmultiple compressor systems variable operating schedules (up to fouf distinct daytypes) ability to predict annual compressed air system energy use and costs The model was developed in conjunction with a compressed air system audit methodology. Jerome is designed to allow energy auditors to evaluate energy and cost savings for six Energy Efficiency Measures (EEMs). The six EEMs were selected because they were often recommended in previous industrial audits, and have yielded significant energy and cost savings. The EEMs evaluated by Jerome are: 1. Reduce AirLeaks. 2. Manual Staging: compressor minimum and maximum pressures are manually adjusted to minimize or avoid overlap. 3. Unloading Controls: this includes low-unload and load-unload type controls. 4.. Automatic Sequencing: an automatic sequencer is added to the system: compressor sequence is defined by the user, unneeded compressors are turned off. S. Reduce System Pressure: average system pressure, and therefore compressor power, are reduced" 6.. Reduce Run Time: compressors are turned off when not needed. Ten compressed air system audits are currently being conducted to validate and further develop the model. Jerome's baseline accuracy has been verified for each audit by comparing modeled baseline power and energy use with recorded use. For these audits baseline energy use has been within 1% of measured use. Future work will include post implementation power monitoring at some ofthe audited industrial facilities to verify predicted energy and cost savings, and to improve estimates of implementation costs. 353