Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy



Similar documents
Digital-output relative humidity & temperature sensor/module DHT22 (DHT22 also named as AM2302)

Aosong(Guangzhou) Electronics Co.,Ltd

DHT11 Humidity & Temperature Sensor D-Robotics UK (

DS1621 Digital Thermometer and Thermostat

Temp. & humidity Transmitter Instructions

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

HM1500LF Relative Humidity Module

HP03 BAROMETER MODULE Version: 1.1

Calibration Management Software by CyberMetrics (480)

Duct Humidity Transmitter

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

DS1621 Digital Thermometer and Thermostat

TSic 101/106/201/206/301/306/506 Rapid Response, Low-Cost Temperature Sensor IC with Analog or digital Output Voltage

DS Wire Digital Thermometer and Thermostat

T0118 T2118 T3118. Instruction Manual

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Green House Monitoring and Controlling Using Android Mobile Application

NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range

Small 7-key User-definable Remote Control User s Guide

ICS379. Quad PLL with VCXO Quick Turn Clock. Description. Features. Block Diagram

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Project Plan. Project Plan. May Logging DC Wattmeter. Team Member: Advisor : Ailing Mei. Collin Christy. Andrew Kom. Client: Chongli Cai

USER MANUAL V5.0 ST100

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

LOW POWER SPREAD SPECTRUM OSCILLATOR

DS1307ZN. 64 x 8 Serial Real-Time Clock

Wireless Temperature

MMC314xMR. Ultra Small 3-axis Magnetic Sensor, With I 2 C Interface. Signal Path X. Signal Path Y. Signal Path Z FEATURES

HTM2500LF Temperature and Relative Humidity Module

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

SHT1x / SHT7x Humidity & Temperature Sensor

HIH-4000 Series Humidity Sensors

DALLAS DS1233 Econo Reset. BOTTOM VIEW TO-92 PACKAGE See Mech. Drawings Section on Website

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

DS1821 Programmable Digital Thermostat and Thermometer

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

HDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Temperature & Humidity SMS Alert Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Inwall 4 Input / 4 Output Module

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Low-Cost Data Loggers and Accessories

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Online Infrared Flue Gas Analyzer Gasboard 3000

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Product Datasheet P MHz RF Powerharvester Receiver

Electronic Pressure Switch EDS 300

Adjustment functions for both span and shift have been incorporated

Signal Manager Installation and Operation Manual

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

EC-TOUCH. RGB LED Controller

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

SMART SENSOR COLLECTION

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

Microcontroller to Sensor Interfacing Techniques

Multifunction devices

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Temperature Humidity Meter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

User Manual Color video door phone

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

DISCONTINUED. AtlasScientific. as of 10/21/13. E.C. Circuit. Biology Technology. Features

Dome Camera with IR Night Vision

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Conversion Between Analog and Digital Signals

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

Push button 3gang standard flush-mounted xx

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TENSIONMETER ** code 183_LNRSTW **

Specification of 5 Wire Analog Touch Panel

Android based Alcohol detection system using Bluetooth technology

Series AMLDL-Z Up to 1000mA LED Driver

GSM HOME SECURITY SYSTEM

Repeater Mil-Std-1553B Datasheet

LM118/LM218/LM318 Operational Amplifiers

Digital input modules

WEB log. Device connection plans

PTU Series Transducer Digital Display Indicator User s Manual

UMEC International Corporation

ALARMLINE ANALOGUE Linear Heat Detection System

Flexible Counter Series in DIN size 24 x 48 mm

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH8000 Series ±2.0 %RH Accuracy. Datasheet

PART 1 - INTRODUCTION...

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

Tire pressure monitoring

Photolink- Fiber Optic Receiver PLR135/T1

5000V Graphical Megohmmeter Model 5070

Transcription:

Standard AM2302/DHT22 AM2302/DHT22 with big case and wires Digital relative humidity & temperature sensor AM2302/DHT22 1. Feature & Application: *High precision *Capacitive type *Full range temperature compensated *Relative humidity and temperature measurement *Calibrated digital signal 2. Description: *Outstanding long-term stability *Extra components not needed *Long transmission distance, up to 100 meters *Low power consumption *4 pins packaged and fully interchangeable AM2302 output calibrated digital signal. It applys exclusive digital-signal-collecting-technique and humidity sensing technology, assuring its reliability and stability. Its sensing elements is connected with 8-bit single-chip computer. Every sensor of this model is temperature compensated and calibrated in accurate calibration chamber and the calibration-coefficient is saved in type of programme in OTP memory, when the sensor is detecting, it will cite coefficient from memory. Small size & low consumption & long transmission distance(100m) enable AM2302 to be suited in all kinds of harsh application occasions. Single-row packaged with four pins, making the connection very convenient. 3. Technical Specification: Model AM2302 Power supply 3.3-5.5V DC Output signal digital signal via 1-wire bus Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy humidity +-2%RH(Max +-5%RH); temperature +-0.5Celsius Resolution or sensitivity humidity 0.1%RH; temperature 0.1Celsius Repeatability humidity +-1%RH; temperature +-0.2Celsius Humidity hysteresis +-0.3%RH Long-term Stability +-0.5%RH/year Interchangeability fully interchangeable - 1 -

4. Dimensions: (unit----mm) Your specialist in innovating humidity & temperature sensors Standard AM2302 s dimensions as above Big case s dimensions as above Red wire--power supply, Black wire--gnd Yellow wire--data output 5. Electrical connection diagram: 6. Operating specifications: (1) Power and Pins Power's voltage should be 3.3-5.5V DC. When power is supplied to sensor, don't send any instruction to the sensor within one second to pass unstable status. One capacitor valued 100nF can be added between VDD and GND for wave filtering. (2) Communication and signal 1-wire bus is used for communication between MCU and AM2302. ( Our 1-wire bus is specially designed, it's different from Maxim/Dallas 1-wire bus, so it's incompatible with Dallas 1-wire bus.) Illustration of our 1-wire bus: - 2 -

DATA=16 bits RH data+16 bits Temperature data+8 bits check-sum Example: MCU has received 40 bits data from AM2302 as 0000 0010 1000 1100 0000 0001 0101 1111 1110 1110 16 bits RH data 16 bits T data check sum Here we convert 16 bits RH data from binary system to decimal system, 0000 0010 1000 1100 652 Binary system Decimal system RH=652/10=65.2%RH Here we convert 16 bits T data from binary system to decimal system, 0000 0001 0101 1111 351 Binary system Decimal system T=351/10=35.1 When highest bit of temperature is 1, it means the temperature is below 0 degree Celsius. Example: 1000 0000 0110 0101, T= minus 10.1 16 bits T data Sum=0000 0010+1000 1100+0000 0001+0101 1111=1110 1110 Check-sum=the last 8 bits of Sum=1110 1110 When MCU send start signal, AM2302 change from standby-status to running-status. When MCU finishs sending the start signal, AM2302 will send response signal of 40-bit data that reflect the relative humidity and temperature to MCU. Without start signal from MCU, AM2302 will not give response signal to MCU. One start signal for one response data from AM2302 that reflect the relative humidity and temperature. AM2302 will change to standby status when data collecting finished if it don't receive start signal from MCU again. See below figure for overall communication process, the interval of whole process must beyond 2 seconds. ------------------------------------------------------------------------------------------------------------------------------------ 1) Step 1: MCU send out start signal to AM2302 and AM2302 send response signal to MCU - 3 -

Data-bus's free status is high voltage level. When communication between MCU and AM2302 begins, MCU will pull low data-bus and this process must beyond at least 1~10ms to ensure AM2302 could detect MCU's signal, then MCU will pulls up and wait 20-40us for AM2302's response. When AM2302 detect the start signal, AM2302 will pull low the bus 80us as response signal, then AM2302 pulls up 80us for preparation to send data. See below figure: ------------------------------------------------------------------------------------------------------------------------------------ 2). Step 2: AM2302 send data to MCU When AM2302 is sending data to MCU, every bit's transmission begin with low-voltage-level that last 50us, the following high-voltage-level signal's length decide the bit is "1" or "0". See below figures: Attention: If signal from AM2302 is always high-voltage-level, it means AM2302 is not working properly, please check the electrical connection status. - 4 -

7. Electrical Characteristics: 8. Attentions of application: Your specialist in innovating humidity & temperature sensors Items Condition Min Typical Max Unit Power supply DC 3.3 5 6 V Current supply Measuring 1 1.5 ma Stand-by 40 Null 50 ua Collecting period Second 2 Second (1) Operating and storage conditions We don't recommend the applying RH-range beyond the range stated in this specification. The AM2302 sensor can recover after working in abnormal operating condition to calibrated status, but will accelerate sensors' aging. (2) Attentions to chemical materials Vapor from chemical materials may interfere AM2302's sensitive-elements and debase AM2302's sensitivity. (3) Disposal when (1) & (2) happens Step one: Keep the AM2302 sensor at condition of Temperature 50~60Celsius, humidity <10%RH for 2 hours; Step two: After step one, keep the AM2302 sensor at condition of Temperature 20~30Celsius, humidity >70%RH for 5 hours. (4) Attention to temperature's affection Relative humidity strongly depend on temperature, that is why we use temperature compensation technology to ensure accurate measurement of RH. But it's still be much better to keep the sensor at same temperature when sensing. AM2302 should be mounted at the place as far as possible from parts that may cause change to temperature. (5) Attentions to light Long time exposure to strong light and ultraviolet may debase AM2302's performance. (6) Attentions to connection wires The connection wires' quality will effect communication's quality and distance, high quality shielding-wire is recommended. (7) Other attentions * Welding temperature should be bellow 260Celsius. * Avoid using the sensor under dew condition. * Don't use this product in safety or emergency stop devices or any other occasion that failure of AM2302 may cause personal injury. - 5 -