High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet



Similar documents
Optimux-134, Optimux-125

Optimux-134, Optimux-125

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Optimux-34, Optimux-25

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

DXC-8R/10A/30 Multiservice Access Nodes

IPmux-1E TDM Pseudowire Access Gateway

DXC Family. Multiservice Access Node FEATURES

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

WEB RANger-II Internet Access Router

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Egate-100 Gigabit Ethernet over TDM Aggregation Gateway

IPmux-16L Hub-Site Pseudowire Access Gateway

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node

Loop-IP6700 TDMoEthernet

IPmux-155L Hub-Site Pseudowire Access Gateway

IPmux-155L Version 1.0B

TDMoEthernet. Description

Loop-IP6700 TDMoEthernet

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

Long Range Ethernet Extender

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

ORION TELECOM NETWORKS INC. T1

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

Loop-IP6702 TDMoEthernet

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

How To Extend A Cell Phone Over Wireless To A Long Distance Over A Cell Tower

T1 Backhaul Connectivity Solution All Products :: Application Note

Airmux-200 Wireless Broadband Multiplexer

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Chassis, Power Supply, and Element Management

IPmux-216 TDM Pseudowire Access Gateway

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Product Specifications

FOM-5A, 6A. Asynchronous Fiber Optic Modem

TrueAlarm Fire Alarm Systems

Optimux-XLT1. Multiple T1 and Ethernet Multiplexer Installation and Operation Manual. Notice

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-V4300 MINI DACS E1/ T1 CONVERTER

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

FlexGain Platform. Universal Access Platform. SHDSL.bis and Fiber Access Platform Ddd & Management. Features

Media Converters & Chassis

F2400 FOM II Series Fiber Optic Modem Technical Manual

Delivers instant switching in four different modes for data center, control room, pooling and similar applications.

G-TAP A Series // Data Sheet

Business Access. Universal Line Access Family

Deliver instant switching in four different modes for data center, control room, pooling, and similar applications.

ETX-204A Carrier Ethernet Demarcation Device

LA-110. Advanced Integrated Access Device FEATURES

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Datasheet. 1-slot or 4-slot Chassis. Feature. Specifcation. Ordering Information. Compliance. Raisecom Technology Co., Ltd. RC001-1-DC Chassis

VALIANT COMMUNICATIONS LIMITED

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

S-Access Etherlink II Repeater TDM Based SHDSL.bis

Setting Up and Testing the MAX Hardware

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Octal T1-10/100 RIOP Installation Guide

Chapter 5 Cubix XP4 Blade Server

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

MCR1900 Media Converter 19-Slot Chassis

IP Express Multi-Service IP DSLAM

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

L5354 ControlNet Communications Interface

Overview of Cisco 2600 Series Routers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

Cisco Communication Media Module

10/100/1000 Base-T to Gigabit Fiber Media Converter

HARTING mcon 1000 Introduction and features

Delivers instant switching in four different modes for data centre, control room, pooling and similar applications.

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

INTRODUCTION TO MEDIA CONVERSION

White Paper. OPCOM3500 Multi-Service Access Platform INTRODUCTION CHARACTERISTICS

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Job Aid Pre-Installation Information S8500 Media Server

Transcription:

Where to buy > See the product page > High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber Up to 24 Ethernet ports and up to 192 E1/T1 links over fiber and copper Low collocation costs, space and power Single IP address ASCII terminal or Telnet management RADview SNMP management for convenient and low-cost maintenance on PC or Unix (HPOV) platforms

is a low-cost solution for collocating TDM and PSN services, providing simple, plug-and-play connectivity for up to 120 km over fiber and copper. is a high-density SNMP managed transparent rack. The chassis has 12 slots that accommodate up to 12 individual I/O modules (cards). The modules include ASMi and Optimux cards, transmitting up to 24 Ethernet and up to 192 E1/T1 links over fiber and copper. All cards and cables are hot-swappable and can be replaced or removed during operation without causing interference to data transmission between other cards in the chassis. requires a single IP address. A fully loaded chassis saves two-thirds of the space needed in comparison with the equivalent solution in standalone units. SHDSL.bis Branch 4 x FE ASMi-54 Router SDH/SONET Central Office SHDSL Branch FE ASMi-52 Router IP/MPLS Fiber Branch FE Optimux-108 4 x E1 Router NMS PBX Figure 1. Powerful Low-Cost Solution for Ethernet and TDM CPEs

FIBER CARDS Each OP-108C/106C module can work with two remote devices. Dual OP-108C/106C modules that feature up to 4 E1/T1 ports per section and transmit up to 100/75 Mbps of Ethernet traffic from each remote device, enable a wide range of applications that require E1/T1 and Ethernet services. COPPER CARDS Each ASMi-54C module features two Ethernet ports for transmission over 16-wire SHDSL lines and can work with remote devices in the following combinations, depending on the application requirements: 2 x 8-wire ASMi-54 standalone modems 4 x 4-wire ASMi-54 or ASMi-54L standalone modems 8 x 2-wire ASMi-54 or ASMi-54L standalone modems. The ASMi-54C/N module features eight E1 ports for transmission over 16-wire SHDSL/SHDSL.bis lines and works with 8 x 2-wire/4 x 4-wire ASMi-54, ASMi-54L, ASMi-52, or ASMi-52L standalone modems. When ordered with Ethernet ports, the module also transports Ethernet over SHDSL/SHDSL.bis lines.

Table 1. Modules Module Technology Working with Description Power Consumption OP-108C Fiber optic Optimux-108, Optimux-108L Dual multiplexer combining four E1 channels, with 100 Mbps Ethernet from each of the multiplexers over a single link, up to 120 km (75 miles), fiber optic link redundancy option OP-106C Fiber optic Optimux-106 Dual multiplexer combining four T1 channels, with 75 Mbps Ethernet from each of the multiplexers over a single link, up to 120 km (75 miles), fiber optic link redundancy option ASMi-54C SHDSL.bis ASMi-54/4ETH (2W,4W,8W) ASMi-54L/4ETH 16-wire, SHDSL.bis modem, two Ethernet 10/100BaseT ports, UTP or SFP 8W 8W 14.5W ASMi-54C/N SHDSL/ SHDSL.bis ASMi-54/4ETH and/or E1 ASMi-54L/4ETH and/or E1 ASMi-52/ETH and/or E1 ASMi-52L/ETH or E1 16-wire, SHDSL/SHDSL.bis modem, eight E1 ports and two optional Ethernet ports ASMi-54C/E1/N: 7.3W ASMi-54C/E1/ETH/N: 12W

MANAGEMENT The modem rack is managed by a Unix- or PC-based SNMP management system. The software (RADview-EMS) is user-friendly, GUI-based, and runs on PC/Windows or HP-OpenView platforms. The SNMP management session runs over a 10/100BaseT Ethernet port. To protect network operations against unauthorized access, features SNMP management with authentication and privacy per SNMPv3, with continued support for SNMPv1. Network management allows centralized control of all hubs, I/O modules and remote units in the network. The management system provides interface configuration, connection setup, alarm monitoring and diagnostic testing. A single management station can control up to 64,000 hubs. can also be managed from an ASCII terminal (which performs all management functions without a GUI interface) and Telnet, which allows terminal connection over any IP network. In addition, alarms can activate dry contacts located on the alarm connector of the CL.1/CLS.1 card. New software versions can be downloaded to the CL.1/CLS.1 card from a remote site via TFTP. restores fragmented IP data sent to the rack by the network management station. Up to five modem and system configuration databases can be stored. All databases can be copied to any media and used for backup or configuration purposes. E1/T1 Metro Ethernet BTS E1/T1 IMA BSC n x FE Optimux-108/ Optimux-106 Node B WMAX Ethernet Modular 1 Modular 1 Transport Network n x E1/T1 Fiber Switch Fiber RNC 4 x E1 Optimux-108L BTS Figure 2. Cellular Backhaul over Fiber

TIMING Each I/O module installed in the chassis has its own independent timing subsystem, with an internal oscillator that can serve as its timing source. In addition, other clock sources are available, such as internal clock source or recovered clock signal from a selected external E1 or T1 interface of an I/O module. The optional CLS.1 modules designed for operation with ASMi-54C/N I/O modules, include an external station clock interface, and a timing distribution subsystem that can supply the external clock signal received through the CLS.1 module CLOCK connectors to the I/O slots. The external clock signal is provided by a highly-accurate master clock source, which is often available at communication facilities (for example, a signal provided by a GPS-based timing source, an independent primary clock source, clock signals provided by an SDH/SONET ADM, or other suitable clock source). POWER operates with either single or dual AC or DC power supplies. A power supply can be replaced during operation (hot-swapped), without affecting system performance. Table 2. LRS Family Comparison Chart LRS-16 Ver 2.0 Ver 3.3 Max. E1 ports 16 192 Max. Ethernet ports 2 (mng) 24 Ethernet performance N/A VLAN aware, VLAN stacking/stripping

Specifications CHASSIS Number of Slots 2 slots for the CL.1/CLS.1 module 2 slots for power supply modules 12 card slots Connectors Each card has its own connector options. The standard front panel can be replaced by a patch panel with BNC connectors, to support unbalanced E1 interfaces (see Ordering). Power AC: 100 to 240 VAC, 47 to 63 Hz, 200W DC: 48 VDC ( 36 to 72 VDC), 200W Physical Height: 17.7 cm (7.0 in) Width: 48.2 cm (19.0 in) Depth: 32.4 cm (12.8 in) Weight: 12.2 kg / 26.8 lb max. (fully loaded chassis) Environment Temperature: 0 to 45 C (32 to 113 F) Humidity: Up to 90%, non-condensing CL.1/CLS.1 CARDS Ethernet Interface Interface: IEEE 802.3 10BaseT (UTP) Connector: shielded RJ-45 Control Port Type: V.24/RS-232 Rate: Selectable 9.6 115.2 kbps Format: Async, 8 bits, 1 stop bit, no parity Terminals supported: VT-52, VT-100, VT-920 Connector: D-type, 9-pin female System Clock Connector RJ-45 Alarm Relay RJ-45 Station Clock (CLS.1 only) Interface: ITU-T Rec. G.703 Connector: RJ-45 Rate: 2.048 MHz 2.048 Mbps 1.544 Mbps Coding: 2.048 Mbps and 2.048 MHz: HDB3 1.544 Mbps: B8ZS Indicators On line (green/yellow): Green On: module is active Green Flashing: standby or software download Yellow On: test exists on active module Yellow Flashing: software is decompressed Alarm (red): On: alarm severity does not exceed minor Flashing: major or critical alarm exists

Ordering STANDARD CONFIGURATIONS /ACR/CL1R management, redundant AC power supply, redundant common logic module /DCR/CL1 management, redundant DC power supply, Common Logic module /DCR/CL1R management, redundant DC power supply, redundant common logic module /UNBAL/DCR/CL1 management, Unbalanced E1 port, redundant DC power supply, Common Logic module /UNBAL/DCR/CL1R management, Unbalanced E1 port, redundant DC power supply, redundant common logic module SPECIAL CONFIGURATIONS /@/$/# Legend @ Front panel type (default: standard front panel with system status indicators) UNBAL patch panel with BNC connectors $ Power supply: AC 100 to 240 VAC, 200W ACR redundant AC power supply DC 48 VDC, 200W DCR redundant DC power supply AD redundant AC and DC power supply # Common logic cards: CL1 Single CL.1 CL1R Dual CL.1 CLS1 Single CLS.1 (with station clock) CLS1R Dual CLS.1 (with station clock) For ordering modem cards, see individual data sheets. SUPPLIED ACCESSORIES AC power cord (when AC power supply is ordered) DC adapter plug (when DC power supply is ordered) RM-MP-MX-23/19 Hardware kit for mounting one unit into both 19-inch and 23-inch racks OPTIONAL ACCESSORIES -PS/~ Additional power supply ~ Power supply type: AC 100 to 240 VAC, 200W DC 48 VDC, 200W -CL/# Additional common logic card # Common logic cards: CL1 Single CL.1 CL1R Dual CL.1 CLS1 Single CLS.1 (with station clock) CLS1R Dual CLS.1 (with station clock) CBL-SP-9 Control port cable 416-100-01/13 (3.4) Specifications are subject to change without prior notice. 1988 2013 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders. International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@radusa.com www.rad.com Order this publication by Catalog No. 823821