The most recent advances in glass encapsulation of microelectronic devices offer important



Similar documents
Recent Developments in Active Implants. Innovation of interconnections for Active Implant Applications

Miniaturizing Flexible Circuits for use in Medical Electronics. Nate Kreutter 3M

Evolving Bar Codes. Y398 Internship. William Holmes

Times Microwave Systems Hermetically Sealed Assemblies

Products for Effective Asset Management

Bourns Resistive Products

Power distribution systems

WW12X, WW08X, WW06X, WW04X ±1%, ±5% Thick Film Low ohm chip resistors

Ball Grid Array (BGA) Technology

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

Smart Wearable Devices Innovation for success Sophisticated solutions in the area of wearable electronics

Mounting Instructions for SP4 Power Modules

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

COPPER FLEX PRODUCTS

Polyolefin Heat Shrink Tubing for Tight-Tolerance Medical Applications

SMA Interface Mating Dimensions (Per MIL-STD-348)

GORE Aerospace Cables and Materials

Development of Biocompatible Coatings on Flexible Electronics

Microchip FAQ's All you wanted to know about microchips but were afraid to ask!

Intelligent implants for diagnosis and therapy

Electronic Board Assembly

Vagus Nerve Stimulation (VNS)

CIRCUITS AND SYSTEMS- Assembly and Printed Circuit Board (PCB) Package Mohammad S. Sharawi ASSEMBLY AND PRINTED CIRCUIT BOARD (PCB) PACKAGE

CIN::APSE COMPRESSION TECHNOLOGY GET CONNECTED...

Effect of Temperature on Wireline Cables Technical Bulletin Ten

Innovative Wafer and Interconnect Technologies - Enabling High Volume Low Cost RFID Solutions

Thermal Management Solutions for Printed Circuit Boards used in Digital and RF Power Electronics and LED assemblies

Flexible Solutions. Hubert Haidinger Director PE/CAM BU Industrial & Automotive 5.June

Flexible Printed Circuits Design Guide

The Don ts of Better Flexible Circuit Design and Manufacture By Mark Finstad Friday, 01 June 2007

T H A N K S F O R A T T E N D I N G OUR. FLEX-RIGID PCBs. Presented by: Nechan Naicker

Development of a Design & Manufacturing Environment for Reliable and Cost-Effective PCB Embedding Technology

Flexible PCB Antenna with Cable Integration Application Note Version 2

Investigation of Components Attachment onto Low Temperature Flex Circuit

Flexible Circuits and Interconnection Solutions

Medical Technologies. Helbling Technik Innovation, together we do it

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

Embedding components within PCB substrates

Determining the Right Molding Process for Part Design

The Heartbeat behind Portable Medical Devices: Ultra-Low-Power Mixed-Signal Microcontrollers

A&C Solutions: please contact us.

Flex Circuit Design and Manufacture.

Precision injection moulding

K.Srinivasu Ravi 1, Seema Kalangi 2, Veeraiah Maddu 3

FLEXIBLE CIRCUITS MANUFACTURING

MRI (Magnetic Resonance Imaging) Arthrogram

RF Energy Harvesting and Wireless Power for Low-Power Applications

Microstockage d énergie Les dernières avancées. S. Martin (CEA-LITEN / LCMS Grenoble)

Molded. By July. A chip scale. and Omega. Guidelines. layer on the silicon chip. of mold. aluminum or. Bottom view. Rev. 1.

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability.

OPTOELECTRONICS PACKAGING FOR EFFICIENT CHIP-TO-WAVEGUIDE COUPLING

PIEZOELECTRIC FILMS TECHNICAL INFORMATION

Good Boards = Results

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

A Novel Flex Circuit Area-Array Interconnect System for a Catheter-Based Ultrasound Transducer

INCORPORATING WEIGHT-SAVING TECHNOLOGY IN AEROSPACE APPLICATIONS: AT WHAT RISK?

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

SENSIMED is a Swiss company with its principal focus on design, development, and commercialization of integrated micro-systems for medical devices.

NATIONAL SUN YAT-SEN UNIVERSITY

Keys to understanding your alarm system

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

A SURVEY AND TUTORIAL OF DIELECTRIC MATERIALS USED IN THE MANUFACTURE OF PRINTED CIRCUIT BOARDS.

Neal O Hara. Business Development Manager

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Lecture 030 DSM CMOS Technology (3/24/10) Page 030-1

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Energy Harvesting Powered Wireless Sensor Node and Asset Tracking Solutions in Random Vibration Environments

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

Balancing the Electrical and Mechanical Requirements of Flexible Circuits. Mark Finstad, Applications Engineering Manager, Minco

How To Wire Wireline Cable To A Cell Phone (New Zealand)

PTFE Slide Bearings 04/10 149

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1

Medical technology Innovation for success Customized solutions in medical technology

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

Company and Product Presentation

PRODUCT DATASHEET. Confidex Ironside Micro CONTENTS

1.Introduction. Introduction. Most of slides come from Semiconductor Manufacturing Technology by Michael Quirk and Julian Serda.

NeuroStar TMS Therapy Patient Guide for Treating Depression

RFID BASED VEHICLE TRACKING SYSTEM

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

A Manufacturing Technology Perspective of: Embedded Die in Substrate and Panel Based Fan-Out Packages

1. Single sided PCB: conductors on only one surface of a dielectric base.

SMA Connectors. RF Coax Connectors. Product Facts

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3

Polymer Termination. Mechanical Cracking 2. The reason for polymer termination. What is Polymer Termination? 3

Energy harvesting in wireless applications

Lead-Free Product Transition: Impact on Printed Circuit Board Design and Material Selection

AND8464/D. Board Level Application Note for 0402, 0502 and 0603 DSN2 Packages APPLICATION NOTE

SPECIFICATION. PART NO. : MT0380-UV-A 5.0mm ROUND LED LAMP. 3Northway Lane North Latham,New York

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Lab-on-a-Chip Design + Foundry Service

Solid-Cast Versus Resin-Encapsulated Transformers

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

Transcription:

Improvements in Glass Encapsulation Technology Offer Significant Advantages for Implantable Medical Devices By Frédéric Mauron Senior VP, Biomedical Engineering Director, Business & Administration Valtronic SA The most recent advances in glass encapsulation of microelectronic devices offer important benefits to the developers of smart implantable medical devices. These benefits include reduced risk of damage to encapsulated circuitry, high biocompatibility, superior hermeticity, and good mechanical stability. Smart implants (sometimes called active implants) are designed to provide in-vivo diagnostic biofeedback on a patient s condition (blood glucose, intra-ocular pressure, etc.) and/or to provide treatment (such as neurostimulators for the treatment of epilepsy, implantable drug pumps, cochlear implants, and a growing range of others). Often, a smart implant is part of a microsystem designed to measure and transmit diagnostic data, which must function autonomously over its intended lifespan, which might be a single day or several decades long. Glass vs. Alternative Encapsulation Materials Glass encapsulation offers several advantages over common smart implant encapsulation materials such as titanium and titanium alloys. Because of its strength and other features, titanium has long been used in medical implants such as cardiac pacemakers and defibrillators, as well as in replacement hip, knee, shoulder and elbow joints. However, sealing titanium 1

implants against moisture requires the use of a high temperature laser welding technique, so the implants must be substantially larger than they would otherwise be in order to minimize the risk of damaging the circuitry during the welding process. In contrast, the newest cold-welding glass encapsulation techniques allow creating significantly smaller implants than those housed in titanium. Smaller, less invasive implants are easier both for the doctor to implant and for the patient to tolerate. This underscores another disadvantage of titanium in that it offers less than optimal hermeticity (resistance to leakage) for small volumes. In contrast with titanium or its alloys, glass encapsulation offers superior transmission of the radio frequency (RF) signals typically used to send bio data to an external reader or to allow recharging of a rechargeable on-board battery. A typical titanium smart implant requires mounting a relatively large antenna onto the implant s PCB in order to provide sufficient power to transmit RF signals through the housing. In contrast, glass encapsulation is largely transparent to radio signals, so significantly less power is needed to transmit a signal. This allows designers of smart implants to employ smaller antennae and, in turn, create smaller implants. Glass encapsulation offers greater biocompatibility over extended periods than many other implant packaging materials. For example, titanium has been in use in medical applications for decades and is generally considered to offer high biocompatibility; however, allergic reactions to it are not unknown. Several other implant encapsulation materials have also been used over the years, including silicone and multilayer epoxies. However, silicone lacks glass s long durability and high resistance to body fluids, which are essential for long-term applications such as pacemakers or neurostimulators. It is best suited for short-term (24 to 48 hours) diagnostic use, such as for monitoring pressure variations in a patient s intraocular lens as part of treatment for glaucoma. 2

Multilayer epoxy encapsulants have a long history of medical applications with their optimal use being implants with a medium-term (30 days to six months) life. A typical multilayer epoxy application might be a dental implant that measures moisture in a patient s mouth, then stimulates the submandibular gland to produce more saliva. The Next Generation of Smart Implants The use of glass encapsulation can help developers of the next generation of smart implants face a variety of technical challenges. Extending the life of an implant s power supply is a constant concern among implant designers. For example, the battery in a pacemaker or defibrillator typically lasts anywhere from 5 to 15 years, depending on a variety of factors; however, replacing the battery is no simple matter because it actually requires surgery to replace the entire unit. Some researchers are exploring ways to extend the battery s life, perhaps by recharging it remotely from outside the body, via an external RF link. Others are considering the use of various body energy harvesting techniques, drawing on sources such as the patient's heartbeat, blood flow inside the vessels, movement of the body parts, and changes in the body temperature and converting them into electrical energy. There s even been discussion of finding ways to convert the body s own natural salts and sugars into bio-fuel that could be used to power an implant. Glass encapsulation, with its high transparency to RF energy, will simplify this research, as well as that involved in the development of new implant communications and memory functions. Currently, researchers are investigating two main glass encapsulation technologies for use in smart implants: cylindrical glass encapsulation and planar glass encapsulation. Applications for Glass Encapsulated Smart Implants Unlike some other encapsulation technologies, glass encapsulation offers the advantage of an 3

extended lifespan, typically from 1 to 10 years, and potentially much longer. Simple cylindrical glass encapsulated microchips have long been used in veterinary medicine to serve as passive identifiers (for pets, valuable livestock/racehorses, etc.). These battery-free devices are implanted under the animal s skin using a large-bore hypodermic needle. The microchip is designed to be activated by a low-power RF signal emitted by a scanner, which causes the microchip to transmit a unique, preprogrammed identification number. Among human patients, typical applications of injectable cylindrical glass encapsulated implants include those developed for various biological sensing tasks, such as continuous monitoring of glucose in a diabetic patient s interstitial fluid. Future biological sensing applications may include implants designed to monitor a patient s blood pressure or cholesterol levels; one day, it may be possible to package a whole lab on a chip. Applications of planar glass encapsulation (PGE) devices are likely to include far more dense circuitry and high lead counts (up to 100), for use in deep brain stimulation, such as for the treatment of epilepsy or Parkinson s disease, and monitoring of intracranial pressure. Cylindrical Glass Encapsulation (CGE) Technology A variety of materials go into glass encapsulated implants in development today, including borosilicate and bioactive glass (bioglass), quartz, and Kovar Glass. These materials must conform with standards for biocompatibility (ISO 10993-1 Standard for biological evaluation of medical devices that are recognized by the U.S. Food and Drug Administration) and implant moisture tightness (protecting circuitry against breakdown due to moisture). The dimensions of today s CGE implants (see Figure 1) make them increasingly injectable, with outside diameters from 4mm to 8mm, wall thicknesses of just 0.4 0.6mm, and 4

lengths from 12mm to 50mm. Valtronic is currently developing the technology necessary to encapsulate even smaller implants. A CGE implant typically consists only of one tubular glass component. The design of electrical feed-throughs (conductors used to connect two sides of a part, such as a circuit board) for this type of implant is currently under development. This implant design can be used where energy or signal flow are independent from such feedthroughs. Figure 1. CGE implants can be small enough to be injected in a patient with a hypodermic needle. Planar Glass Encapsulation (PGE) Technology As the name suggests, a planar glass encapsulated implant is flat rather than cylindrical (Figure 2). Often, this type of glass encapsulation can serve a function in addition to sealing the microelectronics inside, such as monitoring pressures (such as blood or intracranial) or one day possibly acting as a piezoelectric element to harvest mechanical energy produced by the patient s movements as a source of power for the implant. 5

Figure 2. Compact planar glass encapsulated (PGE) implants. The PGE assembly process (Figure 3) provides for high feature (leads) density in extremely small implants and high hermeticity. Feed-throughs are implanted in the bottom glass shell of the encapsulation sandwich. Next, the tungsten vias are gold plated, followed by the application of gold contacts to the inner and outer surfaces of the glass. After the implant s internal electronics are connected, the top glass shell is added and welded to the bottom glass shell. The last step is the addition of lead interconnections to allow integrating the implant into the patient s body. Figure 3. The PGE assembly process. 6

Advantages of the Valtronic Welding Process Valtronic has developed a room-temperature pulsed laser welding process specifically for sealing PGE implants under special environmental conditions. The temperature inside the implant s cavity remains at less than 80 C throughout the sealing process, which eliminates the potential for heat damage to the encapsulated circuitry. No auxiliary materials such as intermediate layers or adhesives are involved in the encapsulation process, which helps to maintain glass s high biocompatibility. The process also ensures the implant s high hermeticity, preserving the integrity of embedded elements by protecting them from moisture. At the same time, the process s ability to ensure high hermeticity protects patients from the effects of the breakdown of components and material inside the implant. Valtronic s scientists and its research partners have confirmed this high level of hermeticity through extensive tritium leakage tests, steam tests in autoclaves, and direct helium leakage testing. Shear, pressure, tensile vibration and de-bonding energy tests are used to characterize the mechanical stability of the complete implant package. Implant Encapsulation Process Valtronic researchers in Switzerland are currently refining a three-line process for planar implant encapsulation: Process step 1 : Provision of cover glass metallization (inside/outside) 7

Process step 2 : Incoming inspection of the electronic device post curing process contacting electronic device (inside) Quality Control (QC) Curing Process step 3 : Provision of raw material (glass compartment with cavity) combining with cover glass/preparation for sealing joining by laser welding (at room temperature and under special environmental conditions) hermeticity QC packaging (sterilization upon request, depending on further processes required for finishing implants). Valtronic is applying innovative design approaches (Figures 4 and 5), along with its core competencies in device miniaturization and glass encapsulation, to the development of the next generation of smart implants. This new approach involves wrapping the implant in a 600µm-thick silicone jacket to protect the glass and internal electronics from mechanical stresses. Other components of the design include the two-part planar glass encapsulation, ASIC/MEMS/System-in-Package (SiP) electronic component, wire bonded/flip chip 8

interconnections, gold stud bumps, and electrode leads. The whole implant design is just 2.55 millimeters thick, making it small enough for implantation in many different parts of the body. Figure 4. New Valtronic PGE implant design (side view) Figure 5. New Valtronic PGE implant design (top-down view). This proposed design approach is in line with the industry requirements for: Patient safety (through the use of proven biocompatible materials) Longer device autonomy 9

Ease of communicating data (due to the RF transparency of glass) Minimal invasiveness (due to miniaturization and functionalized encapsulation, allowing greater system integration) and Improved interaction with biologic elements for more accurate measurement and stimulation (due to the higher density of feed-throughs). To learn more about our unique capabilities in implant design and development, or to learn more about our engineering consulting or manufacturing expertise, contact your nearest Valtronic office. # # # Contact Valtronic 29200 Fountain Pkwy, Solon, OH 440 349 1239 440 349 1040 inquireusa@valtronic.com 10