Post-insulation of cellar ceiling and cellar walls



Similar documents
Comment Form on Proposed Gut Rehabilitation Alternatives

Signs of insulation problems In the winter. In the summer. conditioning system

Module 3.7. Thermal bridging

Renovating Your Basement

Insulating Basements: Part 3 Basement Wall Systems

Common Problems with Walls

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Foundation. Foundation

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

United States. Why You Should Insulate Foundations. There is a science to adding value.

Energy Company Obligation (ECO): Technical Monitoring Questions

COMMONLY USED RESIDENTIAL BUILDING CODES

Rockwool Flexi Insulation Application Guide

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Water Damage & Repair

In accordance with the Department of Labor and Industry s statute , Subd. 11,

CHAPTER 8- REDUCING THE MOISTURE

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Exterior and Interior Insulation of Heavy Masonry Buildings. In North America and Norway. A comparison

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Moisture Content in Insulated Basement Walls

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

Mold Preventing I nterior System

Improving thermal insulation of concrete sandwich panel buildings

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Chapter 2: Foundations

State of Connecticut Department of Public Health RADON PROGRAM

Molds and mildew are fungi that grow

Best Practices for Crawl Space Insulation

Rev Code of Practice. SIP Technology.

Housing Fact Sheets. Insulation Check-Up

Repair of Spalling and Leaking Clay Brick Building Walls

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Answers to Your Questions from the Webinar

Garver Feed Mill Condition Evaluation

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

19 Examples of Wall Insulation

Fiberglas, Exterior Wall Thermal Insulation

Building Envelope. Overview

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Home inspectors are not mold inspectors, however they do inspect for defects that

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Elevating Your House. Introduction CHAPTER 5

bout your house before you start Renovating Your Basement Moisture Problems

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

Safeguard Waterproofing Systems. Creating useable. living space. by making basements dry

BBS/13. Redcliffs 1: Build Back Smarter Case Study

Basement Insulation Systems

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

2009 IECC Update. Scope. Content. International Energy Conservation Code

BUILDING IN ALASKA HCM-00952

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

innovation makes us the better building choice.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Basement Insulation: Best Practices for Efficient, Durable, & Healthy Homes

CONDENSATION IN REFRIDGERATED BUILDINGS

Development of conservation compatible new materials for envelope retrofitting of historic buildings

bout your HOUSE before you start Renovating Your Basement Moisture Problems

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Composite Panel Firewall Systems

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Aalborg Universitet. Reduction of moisture problems in old basements Brandt, Erik; Møller, Eva B.; Vesterløkke, Michael

Advice Series. the maintenance and repair of historic buildings

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

Before You Start an Energy Efficiency Retrofit The Building Envelope

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Solving Persistent Moisture Problems and Moisture Damage

Underwriters Laboratories Testing Information

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Conversion. 03 Re-Use and

DELTA Premium Moisture Management Systems for Foundations.

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

The minimum reinforcement for the stem wall is the placement of:

DEFAULT HEAT LOSS COEFFICIENTS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Condensation. Some Causes, Some Advice

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Garden Bothy, Cumnock

The Pleasance, Edinburgh

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

Performance of 8 Passive House Envelopes in Cold Climates

HOW TO INSULATE A CRAWLSPACE

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Transcription:

WP5 Education and Economic Promotion Post-insulation of cellar ceiling and cellar walls Educational product: New lecture material for training modules dealing with knowledge and skills how to apply suitable methods of energy efficient refurbishment of historic constructions and how innovation can be combined with cultural heritage

Post-insulation of cellar ceiling and cellar walls Target group: architecture, construction, energy audit students Educational objectives: To show the possibilities and methods for further improving building envelope. This measure can help to save up to 3% total energy used in building Lecture course: 2 academic hours, additional on-site visit recommended References: Megri, Ahmed C., et al. Thermal Comfort and Energy Analysis for the Slab-on-Grade Floor and Basement of a Building. (2011). Rasmussen, Torben Valdbjørn. Post-insulation of existing buildings constructed between 1850 and 1920. Department of Construction and Health, Danish Building Research Institute, Aalborg University, Hørsholm (2010). Roberts, S., and R. Stephenson. Measure Guideline: Wall Air Sealing and Insulation Methods in Existing Homes. (2012). 2

Table of Contents Introduction Floor insulation Wood floors Solid floors Introduction The project CO 2 ol Bricks considers measures to improve the thermal envelope of buildings constructed with exterior walls of Brick. Measures with a focus on good technical solutions for improving the thermal insulation of the building envelope are outlined. Both buildings with a recognised unique architecture, where measures must be carried out at the inside, and buildings without a recognised unique architecture, where measures can be carried out at the indside as well as the outside, are shown. However, special attention should be paid to prevent degradation of the existing construction when the energy demand for heating and thermal comfort of a building decreases as a result of measures to improve the thermal envelope. Besides lower heating costs and reduced CO 2 emissions, improvement of the insulation standard could contribute to the elimination of other aspects of discomfort e.g. from draught originating from cold surfaces inside. Building physics requirements of importance is addressed as well. Houses built before 1980 often have little or no wall insulation. Given that walls can represent most of the building envelope area, ensuring that walls have proper levels of insulation is an essential part of any historic building energy retrofit. Post-insulation of outer walls is the most challenging and most energy effective measure for historic building. The retrofit of interior insulation is commonly implemented to improve energy performance of these buildings, while maintaining their often historic exterior appearance. 3

Fig. 1 Energy losses in typical historic building in BSR Insulation is a key tool in the fight to save energy used in buildings. However, in the rush to insulate consideration must be given to the types of materials used and how suited they are to the original construction. Inappropriate use of cheap, impermeable materials can cause an imbalance in the movement of air and moisture in a building and could lead to problems of decay and damage which in the long run will cost more to remediate. Improved thermal insulation measures of the horizontal partition towards the basement is relevant if the basement is cold. Improvements of the vertical section is carried out by blowing loose-fill mineral fibre insulation into the cavity between the timber beams, see Figure 21 and Figure 22. The cavity allowed 100 mm mineral fibre insulation. Figure 2. Horizontal partition by timber beams towards the basement at the window wall. An improved thermal insulation measure is carried out by blowing loose-fill mineral fibre insulation material into the cavity between the timber beams underneath the clay infill. 4

Figure 3. Horizontal partition by timber beams towards the basement at the load bearing wall. An improved thermal insulation measure is carried out by blowing loose-fill mineral fibre insulation material into the cavity between the timber beams underneath the clay infill. An improved thermal insulation measure of the horizontal partition towards the basement is not relevant if the basement is warm, heated by uninsulated and poorly insulated installations for heating. However, if the basement is warm it might be a good idea to increase the thermal insulation of the basement, see Figure 23 and Figure 24. 5

Figure 4. Vertical section of the loadbearing wall in the basement after improved thermal insulation measures. Figure 5. Vertical section at the base of the loadbearing exterior wall placed on a foundation of concrete. Figure 6. Vertical section at the base of the loadbearing wall in the basement after improved thermal insulation measures. Figure 7. Vertical section of the load bearing wall in the basement after improved thermal insulation measures. 6

Figure 8. Vertical section of the load bearing wall in the basement after improved thermal insulation measures. Figure 9. Vertical section at the base of the load bearing wall in the basement after improved thermal insulation measures. 7

Floor insulation The temperature difference between indoor and the first or basement floor is considerably lower than the temperature differences in external walls of buildings. Studies have shown that floor insulation provides a very small part of the total heat gains in comparison with roof and exterior wall insulation. Floors in historical buildings can also have a great cultural and historical value that makes it harder to install thermal insulation. However, if floor modification or reconstruction is planned the opportunity to improve the efficiency of it should be used [15]. Historical buildings usually have two types of flooring - solid or wood construction floor. Wood floors Insulation process of wood floors is easier in comparison with that of the solid floors. Hygroscopic insulating material is inserted between the joists (see Fig. 10). Figure 10. Insulation from below In Figure 10. insulation is applied from the bottom and the floor boards does not have to be removed. Soft heat insulation material, which is located between the joists are secured with hermetic wood fibre plates. Sheep wool or hemp insulation, which reduces the risk of condensation, would be more appropriate. If the floor is not accessible from downstairs, insulation must be installed from the top. Insulating material may be affixed with permeable membrane or fastenings depending on the insulation material. Hygroscopic insulation materials are the most appropriate [17]. 8

Solid floors Traditionally, for the insulation of solid floors traditional thermal insulation materials are used, that is - foam glass, extruded polystyrene and others, below which waterproofing is incorporated to protect them from moisture. Major risks that should taken into account after the installation of insulation is water vapor condensation and moisture absorption from the soil, because solid floors is in a direct contact with the ground. After the insulation the moisture that was absorbed by the original floor is drawn to fundaments, and then capillary forces move it up the masonry walls. To avoid such risks, a specific method is designed for the floor insulation of historical buildings (see Fig. 11). Fig.11 Lime concrete insulation Method is based on natural, hydraulic lime mixture and isolation mass. These materials have the ability to absorb moisture, and then give it to the environment, creating breathing floor system, which reduces the disadvantages of traditional methods. 9