«Gestion active de la demande énergétique, une approche biomimétique»



Similar documents
Le Hive Experience The best energy is the energy that is not consumed

3-phase, bidirectional energy meter

SMART GRIDS PLUS INITIATIVE

CREATING EMOTIONAL EXPERIENCES THAT ENGAGE, INSPIRE, & CONVERT

emobility WAGO Leading the Charge

Smart Cities. Integrated approach for innovative technologies. 2nd Annual Conference of the ETP on. Budapest, 6th May 2011

23/11/2015 TASK 4 REPORT - TECHNICAL ANALYSIS. Use of Task 4 analyses. Introduction and approach - Task 4 objective

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

Richard Schomberg IEC Smart Grid chair EDF VP Smart Energy Standards

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Industrial Vision Days 2012 Making Cameras Smarter: FPGA Based Image Pre-processing Unleashed

Proposition d intervention

Eurogas Testimonial on Implementing the CEER-BEUC Vision

Certified Project Management Associate - Level D, International Project Management Association, IPMA.

trial: washing machine functionalities and results. Lucio Bianchi Smart Grid Program Manager Indesit Company

Implementation of SAP-GRC with the Pictet Group

Linux A multi-purpose executive support for civil avionics applications?

Wireless Power Charging Is Ready for Cars NOW!

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

Future Entreprise. Jean-Dominique Meunier NEM Executive Director Nov. 23, 2009 FIA Stockholm

GSM HOME SECURITY SYSTEM

Developing quality processes in accreditation agencies to support the development of quality of HEIs: the case of CTI

SPONSOR. In cooperation with. Media partners

Maximization versus environmental compliance

Conversores A/D e D/A para chip de Smart Grid

Ordinance RS on Bachelor and Master studies at the École polytechnique fédérale de Lausanne

Solar Power Frequently Asked Questions

Product Information Sheet UH36 Hi Pot Tester

Success Story. Laserline relies on visualization, control and operating panel from KEBA

Intensium Max. A range of ready-to-install containerised energy storage for renewable energies and grid management

How To Increase Private Consumption

EMPOWER. Local Electricity Retail Markets for Prosumer Smart Grid Power Services

Your own power station: For continuous power

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Autonomous Remote Monitoring System for Landslides Luca Manetti * a, Andrea Terribilini ** b, Alfredo Knecht* a

Smart buildings in smart grids KNX City. Rafael Marculescu May 2013

Natural geothermal energy.

Counter for Energy. We make energy measurable and secure your future.

For every mission, there is a Vector. VECTOR

ENERGY SERVICES& ESCOS & THE ROLE OFBELESCO LIEVEN VANSTRAELEN IN BELGIUM

Energy Cost Reduction through Load Balancing & Load Shedding

The Smart Grid: Utility Master Energy & Sustainability Planning

Machine de Soufflage defibre

Smart House And Home Automation Technologies

Energy Tutorial: Energy Usage. Reading meters and understanding fuel bills

MyWatt Cloud 10ch. Wireless Smart Electricity Monitor Challenge the World

Demand Response in the Pacific Northwest

CARINAnav SMART LASER CONTROL

Javier Marín Private Banking, Asset Management and Insurance

THE SOLAR TRANSFORMER. Portable Integrated Solar Power

ZigBee Home Automation Delivering Peace of Mind through Secure and Energy Efficient Homes. August 1, 2013

A Lean journey. Presented at the APEX symposium May 27, Jennifer Little Transport Canada. France Bergeron Alpen Path Solutions Inc.

SRS2025. Home & small Business. Energy Storage Solution

Renewable Energy in Telecom 2nd India Specific working group: Green Power for Mobile

CORPORATE PRESENTATION

BADMINTON SWISSINTERNATIONAL

Note concernant votre accord de souscription au service «Trusted Certificate Service» (TCS)

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

AMTRON. The home charging station. Charged with ideas. MENNEKES COLUMN TITLE

VIREMENTS BANCAIRES INTERNATIONAUX

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

ROTEX gas hybrid heat pump. A strong team.

Convergence Retailing Automation. Maximize efficiency. Reduce costs. Enhance customer experience.

Le point de vue d un équipementier

KNX city concept. Dipl.-Ing. Lutz Steiner, KNX Scientific

Seedling Internet of Things (IoT) and Wearables Platform

Il est repris ci-dessous sans aucune complétude - quelques éléments de cet article, dont il est fait des citations (texte entre guillemets).

Future delivery of BIM-based & standard-based applications and services: an insight in French and European developments. A vision from CSTB

Daikin Altherma Hybrid Heat Pump

Automatic start of a generator

Rousseau 10. User Guide

Overview of Tallahassee s Smart Grid Initiative

New Business Models for Utilities. Own consumption regulation and decentralized storage systems as basis for new business models

Simulations EM à la HEIG-VD

Transcription:

Stignergy SA Y-Parc Swiss Technopole Rue Galilée 7 CH 1400 Yverdon-Les-Bains «Gestion active de la demande énergétique, une approche biomimétique» Sami Najjar, CEO sami.najjar@stignergy.ch M. +41 76 223 53 15 Journée Aristote Du 3 juin 2014 École polytechnique Palaiseau

Vision & Mission: Global leader of Control & Optimization of Electrical Energy Demand for professionals Locations: Stignergy SA - Headquarters & Busdev Y-Parc Swiss Technopole Yverdon-les-Bains (CH) Ra&D - Logistics Branch Office Tunis Founded: HEIG-VD SpinOFF Yverdon-les-Bains, November 2012 Personnel: 5 Ra&D 2009 2015 Budget CHF 3 million Expected Revenue: CHF 4 million in 2016

Team Sami Najjar: CEO & Founder HES engineer graduated. Senior Telecom & IT Engineer Cable & Wireless Startup experience: Keycom SA founder from 2004 to 2008 Alexandre Wetzel: CTO MS in Communication System EPFL Software development specialist in networking and mobility Montassar Ben Abdallah: Logistic & Quality Manager Electronics engineering graduated from the National School of Engineers of Tunis (ENIT). PFE HEIG-VD Switzerland. Youssef Sahbi: Software Engineer Software engineering graduated from the National School of Engineers of Tunis (ENIT). PFE HEIG-VD Switzerland. Ghada Dhibi: Hardware Engineer Electronics engineering graduated from the National School of Engineers of Tunis (ENIT). PFE HEIG-VD Switzerland.

Challenge Energy Consump.on kwh

Solution s aim Bill reduction : 10 to 15% and ++ 10 000 CHF/year for a medium hotel (from 265 kw to 186 kw) Power [kw] Peak demand not controlled Power [kw] Heat Pump Fridge Washing Machine Computer, Light, etc. Fridge Energy demand Heat Pump Washing Machine Peak demand controlled Fridge Fridge Computer, Light, etc. 11:00 11:15 11:30 11:45 12:00 12:15 12:30 11:00 11:15 11:30 11:45 12:00 12:15 12:30

SEMS: Smart Energy Management System

Benefit

SEMS services

Philosophie " Bio- inspiré : Intelligence ar.ficielle inspiré de la nature, du comportement des insectes sociaux. Le cas des abeilles vivant en essaim : l échange d'informa.on entre elles (la distance, la direc.on, la quan.té et la nature de la nourriture) fait que, globalement, elles arrivent à résoudre des problèmes difficiles, (exploita.on de sources de nourriture, construc.on de rayons, etc.). " Une intelligence collec.ve émerge de l interac.on entre des agents rela.vement simples. " L ac.on collec.ve des agents trouve des solu.ons au problème sans aucun superviseur. " Stignergy est inspiré des principes de la S.gmergie qui se réfère au comportement d insectes sociaux.

SEMS Assembly

Measurements series

Appliances usage Unpredictable appliances (Unknown start date, unknown duration ) semi-predictable appliances (Unknown start date, known duration ) [ P ] ON/OFF Decision ON/OFF Decision [ P, T ] SEMS Algorithm ON/OFF Decision Predictable appliances (Known start date, known duration) [ P, T, earliest date, latest date]

Appliances behavior Service Electrical duty cycle Permanent Temporary Periodic Aperiodic Pilotable Non-pilotable Pilotable Non-pilotable Modifiable (Deleting) Interruptible (Interrupt) Shiftable (Postponing)

SEMS actions Energy demand Average demand 11h00 11h15 11h30 11h45

SEMS actions Energy demand 1. 2. 3. Postponing the start Deleting a cycle Interrupt the appliance Average demand 11h00 11h15 11h30 11h45

SEMS operations Two phases Learning The terminals just measure the electrical consumption Duration: about one week Executing The terminals are active and decide to switch ON or OFF their associated appliance Optimizations start in this phase

SEMS Learning - Profiles Profiles are used to represent the consumption of a device based on measurements and observations Real measurements Profile Intensity [A] Intensity [A] 1,00 0,80 0,60 0,40 0,20 0,00 1 0,8 0,6 0,4 0,2 0 1 11 21 31 41 51 61 71 81 91 101 111 121 Time [min] 1 10 19 28 37 46 55 64 73 82 91 100 109 118 127 Time [min]

SEMS Learning - Profiles Learning - Profiles list Thermic and Thermic clock Simple blocks Average 15 (Avg15) More

SEMS Scope Energy Storage Management: Better valuation of local power production like photovoltaic panel More Energy demand reduction -> More bill reduction CTI grant 621K CHF Stignergy industrial partnership with Leclanché (Yverdon) & academic partnership, MIS of HEIG-VD (Yverdon) SmartGrid integration: SEMS Enable two-way communication between the energy consumer and the energy supplier central system Provide prediction charge to the balance of Demand/Response

Competition Features Dynamic Efficiency Reliability Live reports + SEMS- EDCO Decentralized System Centralized Building Management - Load Shedding StaAc System Roadmap: Energy Storage Management : SEMS- ESCO SmartGrid IntegraAon Demand/Response : SEMS- GridExchange M2M Environment : SEMS- M2MEnviro + Advantages Easy installaaon Low investment Fast amorazaaon Simplicity of use VersaAlity Robustness

Value proposition Plug & Reap Savings: 10 to 15% or more of electricity bill Low Investment: Amortization in 24 to 30 months Easy Installation: Max 30 min/terminal, with simple screwdriver Maintenance-Free: No monitoring or maintenance required Large Versatility: Applicable to many types & sizes of buildings or equipments Live Reports: data in real-time

Market The industry and services absorb more than 50% of all electricity consumed in Switzerland. 3% only by the pharma industry *. The figures are basically the same in all Europe. 1st Target Segment: Swiss Hotel Market 2ed Target Segment: Swiss Industry Market 1 000 2 100 4 400 8 600 Monthly Electricity bill ++ : > CHF 40K > 1K Hotels > CHF 44 M > CHF 100K > ++ 2K Industrial Sites > ++ CHF 220 M * http://www.scienceindustries.ch/industrie/industrieportraet/_detail-657/106/energieverbrauch

Questions & Responses