Technical Solution Sheet 7.08 7: Mechanical Services (Including duct heating)



Similar documents
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

A guide to preventing structural damage

CHAPTER 11 STORM DRAINAGE

When considering Roof drainage design the following should be taken into account:

Rainwater is directed away from walls at surface. Any water infiltrating is captured in drains below foundation

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

CHAPTER 11 STORM DRAINAGE

Solving Persistent Moisture Problems and Moisture Damage

Protect your home from basement flooding

BASEMENT FLOODING. Prevention Guide for. Homeowners

Renovation instructions

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

Residential Inspection Guidelines

Why is my air conditioner dripping on my customers?

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Self-Home Inspection Checklist

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Crawlspaces. Bowling Green, KY Stormwater Best Management Practices July No Symbol. Symbol. Immediate and Long Term Problems

Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year

Ductless Heat Pumps. Gary Nordeen January

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

Inspecting to a higher standard.

Additional Services Agreement. Part 3: Schedule of our requirements

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

Cool air quietly and efficiently. A guide to buying and operating an air conditioner

SANITARY SEWER BACKUP. Causes & Prevention

Resources for School Energy Managers

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

PREVENTING WET OR FLO ODED BASEMENTS

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Property Condition Assessment

Downspout Disconnection Program FAQs

Mandatory Weeping Tile Disconnection to Reduce the Impact of Basement Flooding

Energy Efficiency. Energy Efficient Home Cooling:

INSPECTION FINDINGS. for. Paragon Condominiums 2102 W 31 st Avenue Denver, Colorado. Inspection Date: August 8, Perfonned By: Drew Schneider

Home Drainage & Causes of Basement Flooding. Water

PORTABLE AIR CONDITIONER

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

A Guide to Buying and Operating an Air Conditioner

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

CURRENT PRACTICE SHEET

Household customer. Wastewater flooding guidelines.

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Heat Pumps for Swimming Pools

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

bout your HOUSE before you start Renovating Your Basement Moisture Problems

minimum deductible may be increased significantly.

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Australian/New Zealand Standard

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Water Management & Damage Prevention:

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

4.3 Cisterns and Rain Barrels

ORDINANCE NO. 15 BE IT ORDAINED BY THE COUNCIL OF KANSAS CITY:

bout your house before you start Renovating Your Basement Moisture Problems

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Protect Your Home From Flooding. A guide for Lethbridge Residents

Home inspectors are not mold inspectors, however they do inspect for defects that

Answers to Your Questions from the Webinar

Proposed plumbing system within units at the Bluewater Hotel, 10 West Quay, Ahuriri, Napier

Timber Decks. Technical Note. March 2007

Downspout to storm sewer. Leaky laterals

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

Home Maintenance Checklist

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

Home Inspection Report

DESIGN GUIDELINES ROOFING/ROOF PLUMBING

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Open House and Home Tour Checklist

Presentation Agenda. Introduction. Types of Flooding Identifying Flood Risks Property Improvements Additional Resources.

How to Prevent Liquid Damage Property Losses

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

SWIMMING POOL HEAT PUMP

Home Management Checklist: Spring

October 5, 2015 Dear Client,

Commercial Roof Management

GENERAL WIRING RULES FOR HOUSES

Installation Instructions

Ductless Split Air Conditioner

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Investigation Of Water Damage Claims For Subrogation Potential

CENTRAL AIR CONDITIONER SPLIT SYSTEM

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

Housing Fact Sheets. Moisture Condensation at the Windows

DRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer

CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is

ADDENDUM NO. 1. DATE: February 10, 2015 INVITATION FOR BID: IFB K Commerce Road Renovations Project DATED: February 9, 2015

2014 British Columbia Building Code Changes

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

Transcription:

7: Mechanical Services (Including duct heating) Split System Air Conditioning AIM The aim of this technical solution is to inform practitioners on the requirements for the safe discharge of condensate from split system airconditioners, and the secure fixing of condenser units. Note: This technical solution may be read in conjunction with other technical solutions that contain further information relating to condensate drainage for air-conditioning systems. PLUMBING REGULATIONS 2008 The Plumbing Code of Australia (PCA) is adopted by and forms part of the Plumbing Regulations 2008. Part CI of the PCA specifies the objectives and performance requirements related to the installation of sanitary plumbing systems. AS/NZS 3500.2: Plumbing and drainage Part 2: Sanitary plumbing and drainage is a deemed to satisfy document listed in Part CI of the PCA and contains a section on Connection of tundishes. The material used for the drain must be suitable for the purpose and if a plastics material is used it must be of a type suitable for installation in direct sunlight. Pumped condensate; If condensate from an indoor unit has to be pumped to its drainage termination point it is essential that the pump is installed in an accessible position for service/maintenance purposes. Termination points; Figures 1 to 8 on the following pages provide guidance on the approved methods of discharge for condensate drains from split system air-conditioning. 1 Discharge onto a garden bed 2 Discharge onto a concrete or paved surface 3,4,5 & 6 Discharge to a downpipe 7 & 8 Discharge to a sanitary draining system via a tundish. FIGURE 1 - DISCHARGE ON TO A GARDEN BED The Plumbing Regulations 2008 states that, Residential heating, cooling and airconditioning equipment must be installed in accordance with HB 276: A Guide to Good Practice for Energy Efficient Installation of Residential Heating, Cooling & Air Conditioning Plant & Equipment. CONDENSATE DRAINAGE FOR SPLIT SYSTEM AIR-CONDITIONERS Drain Material www.vba.vic.gov.au Page 1 of 6

FIGURE 2 - DISCHARGE ONTO A CONCRETE OR PAVED SURFACE FIGURE 4 - DISCHARGE TO A DOWNPIPE Requirements: The surface must be graded away from the building so that ponding does not occur, and the discharge does not present a safety risk to pedestrians (e.g. across a footpath), nor cause damage to buildings by changing moisture conditions. FIGURE 5 - DISCHARGE TO A DOWNPIPE FIGURE 3 - DISCHARGE TO A DOWNPIPE Note: Caution must be heeded when connecting into a downpipe that the condensate drain does not cause an obstruction in the downpipe. www.vba.vic.gov.au Page 2 of 6

Figures 3, 4 & 5 Requirements: 1. There is a form of disconnection to prevent leakage into the building from the indoor unit if there is blockage in the downpipe (see Figures 3 & 4); and 2. The connection to the downpipe is a minimum of 300mm below the drain outlet of the indoor unit (see Figures 5). FIGURE 6 - DISCHARGE TO A DOWNPIPE VIA A LOWER METAL ROOF Requirements: The connection is above the level of the water seal and the top of the tundish is above the overflow level of the fixture. In accordance with AS/NZS 3500.2 Clause 4.6.7.8 and 11.22. FIGURE 8 - DISCHARGE TO A SANITARY DRAINAGE SYSTEM VIA A TUNDISH TO A FLOORWASTE GULLY FIGURE 7 - DISCHARGE TO A SANITARY DRAINAGE SYSTEM VIA A TUNDISH TO A FIXTURE TRAP Requirements In accordance with AS/NZS 3500.2 Clauses 4.6.7.8 and 11.22. EXTERNAL CONDENSING UNITS INSTALLED ON BALCONIES Where the condensing unit is mounted on the balcony of an apartment building or other location where the discharge from the defrost cycle is likely to cause a nuisance, provide a drained safe tray to collect the removed ice build-up on the outdoor coil. An additional requirement is in relation to the installation of external condensing units installed on balconies, patios, decking, or roofs. All these installations require adequate drainage. www.vba.vic.gov.au Page 3 of 6

Of particular concern is the installation of external units on balconies in high rise apartment buildings. It is not acceptable to discharge the drain over the edge of the balcony where it will cause a nuisance; it must be run to the sanitary or stormwater system in accordance with the above provisions and / or Figure 9 below. FIGURE 9 - EXAMPLE OF BALCONY CONDENSATE DRAINS Larger units may require engineering computations to ensure adequate strength of the roof structure. If timber is to be used as a support material on a metal roof it should be red gum to minimise the possibility of staining the roof as it weathers. The red gum can be painted if necessary to further protect the timber and the roof. It is not permitted to install timber bearers in the tray section of a metal deck roof as support for an outdoor unit, because the flow of water in the tray is impeded (see Figure 10). If timber bearers are to be used as a support, ensure they are placed on top of the ribs and insulated from the metal by a suitable material (e.g. rubber waffle pads) to prevent corrosion occurring and to assist in the reduction of noise transmission. The unit should also be restrained from movement by brackets and / or stays (see Figure 11). PLACEMENT OF AN OUTDOOR UNIT ON A METAL DECK ROOF The following provides guidance for the installation of small domestic size outdoor units on a metal deck roof. You must ensure that the weight of the unit is not excessive for the design of the roof structure. www.vba.vic.gov.au Page 4 of 6

FIGURE 10 - EXAMPLE OF AN OUTDOOR UNIT ON A DECK ROOF FIGURE 11 - EXAMPLE OF AN OUTDOOR UNIT ON A DECK ROOF APPROPRIATELY SUPPORTED PLACEMENT OF AN OUTDOOR UNIT AT GROUND LEVEL Condensing units whether wall mounted on brackets or at ground level on an appropriate support base should be installed to prevent the transmission of vibration to the adjacent building structure and secured appropriately to the bracket or base. Outdoor units should be mounted level on an appropriate wall bracket or support base and restrained from movement by means of suitable fixings, at the base and to the adjacent wall if required. Always follow the manufacturer s instructions to ensure there is an adequate space between the back of the unit and the wall for ventilation (see Figure 12). www.vba.vic.gov.au Page 5 of 6

FIGURE 12 - BRACKET SECURED TO A WALL www.vba.vic.gov.au Page 6 of 6