OneCommand Manager Application for the Drivers for Linux Release Notes
|
|
|
- Clare Lawson
- 10 years ago
- Views:
Transcription
1 OneCommand Manager Application for the Drivers for Linux Release Notes Version: System: SLES 10 SP3 and SP4 (X86, X64 and PPC) SLES 11 SP1 (X86, X64, IA64 and PPC) RH 5.5(X86, X64, IA64 and PPC) RH 5.6 (X86, X64, IA64 and PPC) RH 5.7 (X86, X64, IA64 and PPC) RH 6.0 (X86, X64 and PPC) RHEL 6.1 (X86, X64 and PPC) Date: September 2011 Purpose and Contact Information These release notes describe the new features, resolved known issues and current known issues associated with this OneCommand Manager application version for the Emulex drivers for Linux release. For the latest product documentation, go to If you have questions or require additional information, contact an authorized Emulex technical support representative at (US/Canada toll free), (US/International), or (Europe, Middle East, and Africa). New Features 1. Host grouping display for discovery-tree fabric view. 2. Fabric-centric port selection is included on the Batch Operation dialog box. 3. In the discovery-tree, you can now search with the host name. 4. PCI Express bus speed and bus width information are added to a universal converged network adapter (UCNA) Info tab. 5. Supports diagnostic dumps for OneConnect OCe10102-x UCNAs and OneConnect OCe11102-x UCNAs. 6. Supports IPv6 remote management. 7. Supports OneConnect OCe11102-xT 10GBASE-T UCNAs. 8. New adapter management relative to application programming interfaces (APIs). New adapter management includes the Resource Management Application Programming Interface (RMAPI) library, Common Information Model (CIM) and Simple Network Management Protocol (SNMP). SNMP is supported for network interface card (NIC) and iscsi only. 9. View Vital Product Data (VPD) for NIC-only and iscsi OneConnect OCe1110x UCNAs. You cannot view NIC or iscsi VPD on the OneConnect OCe1010x UCNAs. OneCommand Manager Application for the Drivers for Linux Release Notes 1
2 Resolved Issues 1. When rapidly selecting or deleting iscsi targets from the One Command Manager application Target List box, a parse error message could have occurred. This issue has been corrected. Known Issues 1. For iscsi ports, if you enable the Dynamic Host Configuration Protocol (DHCP) from the Port Information tab s Modify TCP/IP Configuration dialog box and VLAN is already enabled, the following TCP/IP addresses may not be obtained from the DHCP server (remaining ): IP address, subnet mask and gateway address. You may encounter this known issue if your DHCP Server is not VLAN-aware or is not configured for VLAN. Use one of the following workarounds: Use a DHCP Server that is VLAN-aware and properly configured. Follow these steps to disable and enable DHCP and VLAN: a) On the Port Information tab, click Modify. The Modify TCP/IP Configuration dialog box is displayed. b) Clear the VLAN Enabled and DHCP Enabled checkboxes. c) Click OK. The Port Information tab is displayed. d) On the Port Information tab, click Modify. The Modify TCP/IP Configuration dialog box is displayed. e) Check the VLAN Enabled and DHCP Enabled checkboxes. f) Click OK. 2. OneConnect OCe1010x UCNAs are not taken offline. When you start the diagnostic tests, there is the following message: "The test sequence you are about to run will result in taking the selected adapter off line... Click 'OK' to run the test, or 'Cancel to skip it.' However, when you click OK the adapter is NOT taken offline. Unplug the port on the OneConnect OCe1010x UCNA before running the desired diagnostic test. 3. Diffie-Hellman Challenge Handshake Authentication Protocol (DH-CHAP) is not supported on SLES 11 SP1 and RH6 systems. The fcauthd authentication daemon is supported for RH 5.5 and RH 5.7 systems. The fcauthd authentication daemon is not supported for SL11 SP1, RH 5.6 and RH6 systems. 4. OneConnect upgrade path order recommendation. When upgrading UCNA driver and firmware versions, it is best to upgrade both the driver and the firmware without any reboot in between to minimize the possibility of operating with mismatched versions of driver and firmware. OneCommand Manager Application for the Drivers for Linux Release Notes 2
3 5. The NIC driver must be installed to run the OneCommand Manager application on an FCoE adapter. If the OneConnect FCoE adapter is run without the NIC driver installed, many of the management functions are unavailable. The management functions that are unavailable are: 1. Firmware download Active and flash firmware versions Firmware status BIOS version Boot code version All diagnostics including beaconing Transceiver data display Port disable Physical port link status All CEE settings Event log display (CLI only) Diagnostic dumps 6. CLI (hbacmd.exe) path change. Prior to version 5.1, the hbacmd executable file was installed in /usr/sbin/hbanyware directory. For OneCommand Manager version 5.2, this installation directory has been moved to usr/sbin/ocmanager. However, to allow scripts with hard coded paths to the hbacmd executable in the hbanyware directory to continue to run, a copy of the hbacmd executable is still available in the hbanyware directory. 7. Restriction in assigning DCB priorities to priority groups. Although there are eight priority groups to which priorities can be assigned, you are able to assign priorities and bandwidths to only two of the priority groups. To one priority group you must assign the FCoE or iscsi priority and to the other priority group you must assign the other seven (NIC) priorities. Note: If you are using a DCBX enabled switch to configure the priority groups, configure it for only two priority groups to work correctly with the OneConnect adapter. 8. Requirement for unloading or loading Emulex Device Drivers (FC/FCoE, NIC and iscsi). If you load or unload an Emulex device driver for Linux (FC/FCoE, NIC and iscsi) after the machine is rebooted, you must perform the following steps in the following order: 1. Close any open Emulex OneCommand Manager applications. OneCommand Manager Application for the Drivers for Linux Release Notes 3
4 2. Restart OneCommand Manager application daemons. To restart OneCommand Manager application daemons, the daemons must be stopped and started. a) Run the /usr/sbin/ocmanager/stop_ocmanager script. b) Run the /usr/sbin/ocmanager/start_ocmanager script. 3. Run the Emulex OneCommand Manager application GUI and/or the CLI clients applications. 9. If both VLAN and DCBX are disabled, the iscsi priority configured in the CEE tab is not set in the iscsi packets sent out by the port. Enable or disable VLAN from the iscsi Port Info tab in the OneCommand Manager application. 10. DH-CHAP authentication is not supported for OneConnect adapters. There is currently no support for DH-CHAP authentication for OneConnect adapters. The DH-CHAP tab is not displayed by the OneCommand Manager application when an FCoE node of a OneConnect port is selected in the discovery-tree. In the CLI, authentication commands return an error indicating the command is not supported when the OneConnect FCoE port is specified. 11. DH-CHAP authentication is not supported on SLES 11 SP 1 and RH6 systems. The kernel has removed this feature from the FC device driver module layer. 12. Transceiver data is unavailable for OneConnect OCe11102x UCNAs. The transceiver data is not displayed in the OneCommand Manager application or the OneCommand Manager CLI for OneConnect OCe1110x UCNAs. 13. The adapter s WWN may interfere with the OneCommand Manager application s ability to make permanent changes to the adapter s WWN. Some newer adapters (for example, CNAs) on some newer systems employ techniques in the BIOS code at boot time to configure the adapter. This may include the adapter WWN. In such cases, this may interfere with the OneCommand Manager application s ability to make permanent (non-volatile) changes to the adapter s WWN. 14. iscsi InitialR2T is not supported for iscsi OneConnect adapters. Although both the OneCommand Manager application GUI and CLI (hbacmd) clients allow the configuring of the iscsi InitialR2T parameter to yes or no, the adapter does not recognize the setting. The adapter always operates with InitialR2T set to "yes". OneCommand Manager Application for the Drivers for Linux Release Notes 4
5 15. On SLES 11 SP1 and RH6.0 systems, an unavailable in-band remote OneCommand Manager host causes a 30-second window of vulnerability. When an in-band remote OneCommand Manager application host becomes unavailable for any reason (for example, a cable pull or a machine reboot) there is a 30 second window of vulnerability such that FC-CT commands originating from the SL11 SP1 machine to the remote host during this period hang due to a function call that generates an ioctl to the kernel that does not return. The calling process thread is hung. This problem is due to kernel code (new bsg interface) and a kernel fix is in process. This issue has been addressed in the RH6.1 kernel. Inclusion is also expected in SLES 11 SP2. Emulex recommends avoiding use of in-band management for SLES 11 SP1 and RH 6.0 systems. 16. FC-CT commands to the switch that timeout can cause the OneCommand Manager application processes to hang. The OneCommand Manager application uses FC-CT commands to the switch name server to obtain local HBA symbolic name information. FC-CT commands to the switch originating from a SL11 SP1 or RH6.0 machine that time out cause the OneCommand Manager application process sending the FC-CT command to hang. This problem has been found to be located in kernel code (new bsg interface) and a kernel fix is in process. Scenarios that might result in this behavior include disabling a switch port and modifying VLAN configuration either on the switch or on the host machine via the OneCommand Manager application. No workaround at this time. This issue has been addressed in the RH6.1 kernel. Inclusion is also expected in SLES11 SP Messages appear on the terminal during Web-Launch install/uninstall. On Linux SLES11 SP1 systems, when the OneCommand Manager Web-launch feature is installed or uninstalled using wsinstall and wsuninstall scripts respectively, the following messages are displayed to the terminal. insserv: Script jexec is broken: incomplete LSB comment. insserv: missing `Required-Stop:' entry: please add even if empty. These are warning messages that do not affect the operation or installation of the Web-launch feature. They appear on SLES 11 SP1 specific versions of the relevant software (insserv and jexec). The scripts invoke this software via invocation of the standard Linux chkconfig utility typically used for daemon installations. None required. OneCommand Manager Application for the Drivers for Linux Release Notes 5
6 18. On SLES 11 systems, the Open-FCoE RPM package (open-fcoe ) is incompatible with the OneCommand Manager application package and must be removed from the target host machine. The HBA API library that the open-fcoe package installs (libhbalinux.so.1) causes all OneCommand Manager application processes to crash with a segmentation violation. To recover you must reinstall OneCommand Manager application. 19. On RHEL 5.5 systems, the core kit (elxocmcore RPM) and enterprise kit (elxocm RPM) does not install due to a missing Libnl (NetLinks) library. The OneCommand Core RPM requires Libnl. Unlike other supported operating systems, RHEL 5.5 does not install the Libnl package during a default installation. Install the libnl package from the RHEL 5.5 distribution media. 20. On RHEL 5.5 systems, the OneCommand iscsi SNMP daemon does not start. The OneCommand iscsi SNMP daemon does not start if the package that holds the file is not found. s If the OneCommand Manager application is not installed, install the lm_sensors or higher RPM from the Red Hat distribution media. Install the OneCommand Manager application. If the OneCommand Manager application is installed, run the stop_ocmanager script to stop the OneCommand Manager application daemons. Install the lm_sensors or higher RPM from the Red Hat distribution media. Run the start_ocmanager script to start the OneCommand Manager application daemons. 21. On RHEL 5.4 x86 64 and ppc 64 systems, the Red Hat 32-bit and 64-bit libhbaapi RPMs treat /etc/hba.conf as a configuration file. If no application has modified /etc/hba.conf, this file is deleted when the Red Hat libhbaapi RPM is uninstalled. If an application has modified /etc/hba.conf (example: OneCommand Manager application), this file is moved to /etc/hba.conf.rpmsave when the Red Hat libhbaapi RPM is uninstalled. In either case, uninstalling the 32-bit or 64-bit Red Hat libhbaapi RPMs breaks the OneCommand Manager application because it requires Emulex entries in /etc/hba.conf. If the OneCommand Manager application is installed, do not uninstall the Red Hat 32-bit or 64-bit libhaapi RPM. 22. Unloading the NIC driver from the Linux machine causes the OneCommand Manager application to lose connectivity. If you unload the NIC driver from the Linux machine, any OneCommand Manager application (the GUI or the CLI client) running on the machine loses connectivity with the NIC and related configuration data. OneCommand Manager Application for the Drivers for Linux Release Notes 6
7 To recover, you must perform the following steps in the following order: 1. Stop the OneCommand Manager applications and daemons using the stop_ocmanager script. 2. Reload the NIC driver using modprobe. 3. Restart the OneCommand Manager application daemons using the start_ocmanager script. 4. Restart the desired OneCommand Manager application (GUI or CLI client). 23. When MILI and SNMP daemons start, they trigger warning messages within SELinux for certain operations. To avoid SElinux warning messages, disable SELinux. 1. To disable SElinux, open a terminal and enter the following command at prompt: echo 0 > /selinux/enforce 2. To enable SElinux, open a terminal and enter the following command at prompt: echo 1 > /selinux/enforce 24. A permanent driver parameter change fails if the system is rebooted too soon. When you make permanent driver parameter changes via the OneCommand Manager application, the application automatically makes the required entry in the /etc/modprobe.conf or equivalent file. Because the lpfc driver loads so early in the Linux machine boot sequence, the new contents of the /etc/modprobe.conf file must be re-inserted into the Linux system initrd file (via "mkinitrd" utility) for the driver to pick up the new driver parameter value on the next boot. Failure to generate the new initrd file causes the driver to fail to get the new driver parameter value on subsequent driver loads (machine boots). The OneCommand Manager application automatically does this for you (re-creates initrd via mkinit function); however, it can take as long as seconds after the driver parameter is changed for a complete initrd re-build. Thus, if you reboot the machine immediately after the driver parameter change is made, the auto-recreation of the initrd file by the OneCommand Manager application may fail to complete. In these cases, this failure causes the driver to not obtain the new driver parameter value upon subsequent reboots. Wait a minimum of seconds after making the driver parameter change before rebooting the machine. 25. An unaligned access message can appear on the Linux command shell. When running the HBACMD CLI client, the following unaligned access message can appear on the Linux command shell: elxdiscoveryd(24489): unaligned access to 0x f1c, ip=0x20...8fa680 These messages are "informational" only and do not cause any inaccuracies in the OneCommand Manager application configuration or status reporting. These messages are OneCommand Manager Application for the Drivers for Linux Release Notes 7
8 indications that the OneCommand Manager application code execution is sometimes referencing data aligned to four bytes instead of eight and the IA64 architecture issues a page fault to accomplish it (causing a slight performance hit). These messages can be turned off with the prtcl or dmesg Linux commands. 26. Requirement if Data Center Bridging (DCB) settings are connected to a non-dcbx switch. If DCB settings are required when connected to a non-dcbx switch (or a switch with DCBX disabled), DCBX must be disabled on the OneConnect adapter to use the adapter s configured parameters. If DCBX is enabled, DCB PFC and Priority Groups are ignored (the adapter assumes the switch does not support these features) and for FCoE adapters, the FCoE priority (COS) is Newly added LUNs on a storage array may not appear on the host machine Linux operating system or the OneCommand Manager application. Do one of the following: Run the following script from the command shell: /usr/sbin/lpfc/lun_scan all Reboot the host machine after the LUN has been added at the target array. 28. When using IET software, more than 60 iscsi targets may not be discovered. When using the open source iscsi Enterprise Target (IET) software package to present targets to the iscsi initiator, adding target portals that contain greater than 60 targets fails the resulting target discovery operation. This is due to an error in the IET target implementation. 29. Logged in iscsi targets retain login options through reboots. When an iscsi target is discovered by adding target portal, that target takes the target portal s login options. The target portal s login options are taken from the initiator login options. However, you can modify them when adding the target portal. If a target is discovered by isns, it gets its default login options from the initiator login options. Once a target is discovered, its login properties are not changed when the initiator login options are changed. When you log into a target, the login properties used at the time of login are remembered. If you reboot, the logged in targets are logged in again with the remembered login options (i.e. initiator login options are not used). When you remove the targets (and the target portal if that s how they were discovered) and then cause the targets to be rediscovered, the targets login properties are defined once again by how they are discovered as described at the beginning of this known issue. 30. A physical loopback diagnostic test fails if no transceiver is present on a OneConnect OCe1010x UCNA port. OneCommand Manager Application for the Drivers for Linux Release Notes 8
9 Insert a transceiver into the port before you run a physical loopback diagnostic test. 31. A MAC loopback diagnostic test may fail if the cable is plugged into a OneConnect OCe1010x UCNA port. Unplug the port on the OneConnect OCe1010x UCNA before running the MAC loopback diagnostic test. 32. On RHEL 6.0 and RHEL 6.1 systems, the OneCommand Manager application installation may fail as the OCM JRE required the RHEL6 library file: Libstdc++.5.so and that file is not installed by default. Install the compat-libstdc++-33 RPM included in the RHEL 6 distribution. 33. On RHEL 6.0 and RHEL 6.1 systems, an issue exists with the Java Runtime that may result in the inability to run OCManager on a RHEL 6 host. This problem usually occurs on Blade platforms. This issue causes the OneCommand Manager application to crash immediately upon invocation. Use one of the following management methods: Command Line Utility (HBACMD) Manage the problematic RHEL 6 host from a remote host that is running the OneCommand Manager application. Install WebLaunch services on the RHEL6 host, then point a browser on another host to that RHEL 6 host. 34. When you start a diagnostic test on a OneConnect OCe1010x UCNA port, the following message is displayed: "The test sequence you are about to run will result in taking the selected adapter off line... Click 'OK' to run the test, or 'Cancel to skip it.' However, after you click OK, the adapter is not taken offline. Unplug the port on the OneConnect OCe1010x UCNA before running the desired diagnostic test. 35. An end-to-end (ECHO) diagnostic test fails if the corresponding targets are not supported. Check to be sure the connect targets are supported. 36. On a OneConnect OCe1110x UCNA, running tests using the Diagnostics tab may result in an IOCTL error 0x45. None required. This error only appears in the MILI log (not out to the display) and can safely be ignored. OneCommand Manager Application for the Drivers for Linux Release Notes 9
10 37. On an OneConnect OCe1110x UCNA, installing or uninstalling the OneCommand Manager application may result in an IOCTL error 0x45. None required. This error only appears in the MILI log (not out to the display) and can safely be ignored. Technical Tips 1. In the OneCommand Manager application version 5.1, the basic and advanced login options were in different dialog boxes. In the OneCommand Manager application version 5.2, the iscsi Target Discovery tab includes these basic and advanced login options: Manually Add Target Add Portal Target Login Copyright 2011 Emulex. All rights reserved worldwide. This document refers to various companies and products by their trade names. In most, if not all cases, their respective companies claim these designations as trademarks or registered trademarks. This information is provided for reference only. Although this information is believed to be accurate and reliable at the time of publication, Emulex assumes no responsibility for errors or omissions. Emulex reserves the right to make changes or corrections without notice. This report is the property of Emulex and may not be duplicated without permission from the Company. OneCommand Manager Application for the Drivers for Linux Release Notes 10
OneCommand Manager Application for Windows Release Notes
OneCommand Manager Application for Windows Release Notes Version: 6.2.10.3 System: Windows Server 2008, Windows Server 2008 R2, and Windows Server 2012: x64 versions, Enterprise and Server Core installation
Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes
Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Version (Kit): 2.5.25-2 Date: August 2011 Purpose and Contact Information These release notes describe the new features,
Windows Host Utilities 6.0 Installation and Setup Guide
Windows Host Utilities 6.0 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iscsi) for Linux This page is intentionally left blank. Preface This manual briefly explains the operations that need to be performed
Windows Host Utilities 6.0.2 Installation and Setup Guide
Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server
System Storage DS3000 Storage Manager Version 10 Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server System Storage DS3000 Storage Manager Version
How To Install The Safenet-Inc.Com Software On A Pc Or Mac Or Macintosh (For A Powerpoint) With A Powerline (For Windows) Or Ipad (For Mac) With The Safetime (For Pc
End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys 1 Preface Welcome to Safenet End User Troubleshooting guide! This guide is intended to assist our Distributors,
HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions
HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions Congratulations on your purchase of the 8Gb Simple SAN Connection Kit. This guide provides procedures for installing the kit components,
Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN
Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN A Dell EqualLogic best practices technical white paper Storage Infrastructure and Solutions Engineering Dell Product Group November 2012 2012
OneCommand NIC Teaming and VLAN Manager
OneCommand NIC Teaming and VLAN Manager Version 2.0.3 for Windows Server 2003 Windows Server 2008 Windows Server 2008 R2 User Manual P005238-01A Rev. A One Network. One Company. Connect with Emulex. Copyright
End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys
End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys Preface Welcome to Safenet End User Troubleshooting guide! This guide is intended to assist our Distributors, Customers
Emulex Drivers for Windows User Manual FC and FCoE version 2.72.012.001 NIC version 4.2.390.6 iscsi version 4.2.281.0
Emulex Drivers for Windows User Manual FC and FCoE version 2.72.012.001 NIC version 4.2.390.6 iscsi version 4.2.281.0 Emulex Connects Servers, Storage and People 2 Copyright 2012 Emulex. All rights reserved
Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server
Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...
Direct Attached Storage
, page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel
Smart Cloud Integration Pack. For System Center Operation Manager. v1.1.0. User's Guide
Smart Cloud Integration Pack For System Center Operation Manager v1.1.0 User's Guide Table of Contents 1. INTRODUCTION... 6 1.1. Overview... 6 1.2. Feature summary... 7 1.3. Supported Microsoft System
vsphere Host Profiles
ESXi 5.1 vcenter Server 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions
The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.
Emulex HBA Product Evaluation Evaluation report prepared under contract with Emulex Corporation Introduction Emulex Corporation commissioned Demartek to evaluate its 8 Gbps Fibre Channel host bus adapters
Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)
Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2) Hyper-V Manager Hyper-V Server R1, R2 Intelligent Power Protector Main
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
Command Line Interface User Guide for Intel Server Management Software
Command Line Interface User Guide for Intel Server Management Software Legal Information Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel
Getting Started with RES Automation Manager Agent for Linux
Getting Started with RES Automation Manager Agent for Linux Contents Chapter 1: Introduction 1 Chapter 2: Prerequisites and General Guidelines 2 Chapter 3: Installation 3 3.1 Manual Installation... 3 3.2
Honeywell Internet Connection Module
Honeywell Internet Connection Module Setup Guide Version 1.0 - Page 1 of 18 - ICM Setup Guide Technical Support Setup - Guide Table of Contents Introduction... 3 Network Setup and Configuration... 4 Setting
Emulex Drivers for Windows User Manual FC and FCoE version 2.74.009.001 NIC version 4.4.176.2 iscsi version 4.4.165.0
Emulex Drivers for Windows User Manual FC and FCoE version 2.74.009.001 NIC version 4.4.176.2 iscsi version 4.4.165.0 Emulex Connects Servers, Storage and People 2 Copyright 2012 Emulex. All rights reserved
SNMP Manager User s Manual
SNMP Manager User s Manual Table of Contents 1. Introduction...2 2. SNMP Manager Install, Quick Start and Uninstall...2 2.1. Software Installation...2 2.2. Software Quick Start...2 2.3. Software Uninstall...2
PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -
Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors
Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters
Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters Emulex OneConnect Ethernet Network Adapters Introduction This document gives an overview of how to
new Business Online Technical Troubleshooting Guide
new Business Online Technical Troubleshooting Guide TABLE OF CONTENTS How to install Java 1.6 Page 3 How to install Java 1.6 without ActiveX control Page 6 How to uninstall Java Runtime Environment Page
ProSafe Plus Switch Utility
ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting
UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)
UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY) Hardware Installation 1. Initial placement for programming and configuration purposes should be performed in an indoor environment.
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com
CHAPTER: Introduction Microsoft virtual architecture: Hyper-V 6.0 Manager Hyper-V Server (R1 & R2) Hyper-V Manager Hyper-V Server R1, Dell UPS Local Node Manager R2 Main Operating System: 2008Enterprise
Dell PowerVault Modular Disk Storage Manager User s Guide
Dell PowerVault Modular Disk Storage Manager User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE:
CA arcserve Unified Data Protection Agent for Linux
CA arcserve Unified Data Protection Agent for Linux User Guide Version 5.0 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014 Version 1 NEC EXPRESSCLUSTER X 3.x for Windows SQL Server 2014 Quick Start Guide Document Number ECX-MSSQL2014-QSG, Version
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
V310 Support Note Version 1.0 November, 2011
1 V310 Support Note Version 1.0 November, 2011 2 Index How to Register V310 to Your SIP server... 3 Register Your V310 through Auto-Provision... 4 Phone Book and Firmware Upgrade... 5 Auto Upgrade... 6
Installing Virtual Coordinator (VC) in Linux Systems that use RPM (Red Hat, Fedora, CentOS) Document # 15807A1-103 Date: Aug 06, 2012
Installing Virtual Coordinator (VC) in Linux Systems that use RPM (Red Hat, Fedora, CentOS) Document # 15807A1-103 Date: Aug 06, 2012 1 The person installing the VC is knowledgeable of the Linux file system
Practice Fusion API Client Installation Guide for Windows
Practice Fusion API Client Installation Guide for Windows Quickly and easily connect your Results Information System with Practice Fusion s Electronic Health Record (EHR) System Table of Contents Introduction
Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5. Version 1.0
Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5 Version 1.0 November 2008 Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5 1801 Varsity Drive Raleigh NC 27606-2072 USA Phone: +1 919 754
Emulex Driver for Linux
Emulex Driver for Linux FC and FCoE version 8.2.0.63 NIC version 2.101.374.0 iscsi version 2.101.374.0 User Manual P004433-01B Rev. A One Network. One Company. Connect with Emulex. Copyright 2003-2010
Sentinel Protection Installer Version 7.6.3 (32-bit and 64-bit Windows) ReadMe
Sentinel Protection Installer Version 7.6.3 (32-bit and 64-bit Windows) ReadMe This ReadMe provides information about Sentinel TM Protection Installer, its installation and few tips on using the related
Linux Host Utilities 6.1 Installation and Setup Guide
Linux Host Utilities 6.1 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP
ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 3, 2009 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
HP SCOM Management Packs User Guide
HP SCOM Management Packs User Guide Abstract This guide describes the HP extensions for Microsoft System Center Operations Manager that are provided as part of HP Insight Control for Microsoft System Center.
Installing Operating Systems
CHAPTER 6 The unattended operating system installation function helps you install the Microsoft Windows and RedHat Linux operating system families. UCS-SCU has integrated device drivers including RAID
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
HP Insight Diagnostics Online Edition. Featuring Survey Utility and IML Viewer
Survey Utility HP Industry Standard Servers June 2004 HP Insight Diagnostics Online Edition Technical White Paper Featuring Survey Utility and IML Viewer Table of Contents Abstract Executive Summary 3
CommandCenter Secure Gateway
CommandCenter Secure Gateway Quick Setup Guide for CC-SG Virtual Appliance and lmadmin License Server Management This Quick Setup Guide explains how to install and configure the CommandCenter Secure Gateway.
Lab 8.4.2 Configuring Access Policies and DMZ Settings
Lab 8.4.2 Configuring Access Policies and DMZ Settings Objectives Log in to a multi-function device and view security settings. Set up Internet access policies based on IP address and application. Set
Sentinel Protection Installer Version 7.1.1 (Windows) ReadMe
Sentinel Protection Installer Version 7.1.1 (Windows) ReadMe This readme provides an overview of the Sentinel TM Protection Installer, its installation and a few tips on using the related components (such
IBM WebSphere Application Server Version 7.0
IBM WebSphere Application Server Version 7.0 Centralized Installation Manager for IBM WebSphere Application Server Network Deployment Version 7.0 Note: Before using this information, be sure to read the
[HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX3.0.0.0] 1
[HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX3.0.0.0] 1 How to Recover an infiniti/evolution Modem Software Reference idx 3.0.0.0 (12.0.0.0) Updated: November 17 th 2011 Overview Recovery Procedures
Exploring the Remote Access Configuration Utility
Exploring the Remote Access Configuration Utility in Ninth-Generation Dell PowerEdge Servers The Remote Access Configuration Utility supports local and remote server management in ninth-generation Dell
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 This document describes the different types of Unisphere management stations and tells how to install
Release Notes for Fuel and Fuel Web Version 3.0.1
Release Notes for Fuel and Fuel Web Version 3.0.1 June 21, 2013 1 Mirantis, Inc. is releasing version 3.0.1 of the Fuel Library and Fuel Web products. This is a cumulative maintenance release to the previously
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 7, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
PowerChute Network Shutdown v4.1 Release Notes
PowerChute Network Shutdown v4.1 Release Notes The release notes provide important information about PowerChute Network Shutdown (PowerChute), including known software issues and their solutions. For any
COGNEX. Cognex Vision Software. GigE Vision Cameras. User s Guide
COGNEX Cognex Vision Software GigE Vision Cameras User s Guide June 2008 Cognex Software and GigE Vision Cameras Cognex VisionPro and CVL software provide support for acquiring, processing, and displaying
IntraVUE Plug Scanner/Recorder Installation and Start-Up
IntraVUE Plug Scanner/Recorder Installation and Start-Up The IntraVUE Plug is a complete IntraVUE Hardware/Software solution that can plug directly into any network to continually scan and record details
SANbox Manager Release Notes Version 1.03.28 50208-06 Rev A
SANbox Manager Release Notes Version 1.03.28 50208-06 Rev A This software is licensed by QLogic for use by its customers only. Copyright (c) 2001 QLogic Corporation All rights reserved Version 1.03.28
Virtual Storage Console 4.0 for VMware vsphere Installation and Administration Guide
Virtual Storage Console 4.0 for VMware vsphere Installation and Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support
Compellent Storage Center
Compellent Storage Center Microsoft Multipath IO (MPIO) Best Practices Guide Dell Compellent Technical Solutions Group October 2012 THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY
Working Folder Linkage Setup Guide
For models listed below, see the respective "Working Foloder Linkage Setup Guide". wfs-mfp-installguide-09_en.pdf - ApeosPort-IV C5570/C4470/C3371/C3370/C2270 - ApeosPort-IV C7780/C6680/C5580 - ApeosPort-IV
Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples
Networking General networking Networking overview A network is a collection of devices such as computers, printers, Ethernet hubs, wireless access points, and routers connected together for communication
Emulex Drivers for Linux
Emulex Drivers for Linux User Manual P006994-01A Rev. A Emulex Connects Servers, Storage and People EMULEX CONFIDENTIAL. Copyright 2003-2011 Emulex. All rights reserved worldwide. Unpublished work. No
Software Installation Guide
Software Installation Guide This manual explains how to install the software over a USB or network connection. Network connection is not available for models SP 200/200S/203S/203SF/204SF. Flowchart The
HP SCOM Management Packs User Guide
HP SCOM Management Packs User Guide Abstract This guide describes the HP extensions for Microsoft System Center Operations Manager that are provided as part of HP Insight Control for Microsoft System Center.
Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1
Quick Install Guide Lumension Endpoint Management and Security Suite 7.1 Lumension Endpoint Management and Security Suite - 2 - Notices Version Information Lumension Endpoint Management and Security Suite
Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers
Technical white paper Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers Table of contents Abstract... 2 Introduction to Red Hat Enterprise Linux 6... 2 New features... 2 Recommended ProLiant
Dell NetVault Bare Metal Recovery 10.5. User s Guide
Dell NetVault Bare Metal Recovery 10.5 User s Guide Copyright 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell, the
HL2170W Windows Network Connection Repair Instructions
Difficulty printing from your PC can occur for various reasons. The most common reason a networked Brother machine may stop printing, is because the connection between the computer and the Brother machine
Attix5 Pro Server Edition
Attix5 Pro Server Edition V7.0.3 User Manual for Linux and Unix operating systems Your guide to protecting data with Attix5 Pro Server Edition. Copyright notice and proprietary information All rights reserved.
Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice
Phone Adapter with 2 Ports for Voice-over-IP Voice Installation and Troubleshooting Guide Model No. PAP2 Ver. 2 Copyright and Trademarks Specifications are subject to change without notice. Linksys is
Backup & Disaster Recovery Appliance User Guide
Built on the Intel Hybrid Cloud Platform Backup & Disaster Recovery Appliance User Guide Order Number: G68664-001 Rev 1.0 June 22, 2012 Contents Registering the BDR Appliance... 4 Step 1: Register the
OnCommand Performance Manager 1.1
OnCommand Performance Manager 1.1 Installation and Setup Guide For Red Hat Enterprise Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501
Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide
Direct Storage Access Using NetApp SnapDrive Installation & Administration Guide SnapDrive overview... 3 What SnapDrive does... 3 What SnapDrive does not do... 3 Recommendations for using SnapDrive...
PROJECTIONS SUITE. Database Setup Utility (and Prerequisites) Installation and General Instructions. v0.9 draft prepared by David Weinstein
PROJECTIONS SUITE Database Setup Utility (and Prerequisites) Installation and General Instructions v0.9 draft prepared by David Weinstein Introduction These are the instructions for installing, updating,
Configuring Virtual Blades
CHAPTER 14 This chapter describes how to configure virtual blades, which are computer emulators that reside in a WAE or WAVE device. A virtual blade allows you to allocate WAE system resources for use
PTC Integrity Eclipse and IBM Rational Development Platform Guide
PTC Integrity Eclipse and IBM Rational Development Platform Guide The PTC Integrity integration with Eclipse Platform and the IBM Rational Software Development Platform series allows you to access Integrity
Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008
Best Practices Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008 Installation and Configuration Guide 2010 LSI Corporation August 13, 2010
VTrak A-Class. 1.08.0000.00 Release Notes R1.00
VTrak A-Class 1.08.0000.00 Release Notes 1. Release Summary This is a Service Release for the A-Class Shared Storage Appliance with firmware version 1.08.0000.00. It supports Microsoft Windows and Apple
SonicOS Enhanced 5.7.0.2 Release Notes
SonicOS Contents Platform Compatibility... 1 Key Features... 2 Known Issues... 3 Resolved Issues... 4 Upgrading SonicOS Enhanced Image Procedures... 6 Related Technical Documentation... 11 Platform Compatibility
SAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
Software Installation Guide
Software Installation Guide This manual explains how to install the software over a USB or network connection. Network connection is not available for models SP 200/200S/203S/203SF/204SF. To manually configure
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under
Embarcadero Performance Center 2.7 Installation Guide
Embarcadero Performance Center 2.7 Installation Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A.
Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015
Metalogix SharePoint Backup Publication Date: August 24, 2015 All Rights Reserved. This software is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family *5991-5301* Part number: 5991-5301 Edition: 3, E0406 Copyright 2006 Hewlett-Packard Development
WatchGuard Mobile User VPN Guide
WatchGuard Mobile User VPN Guide Mobile User VPN establishes a secure connection between an unsecured remote host and a protected network over an unsecured network using Internet Protocol Security (IPSec).
PART 1 CONFIGURATION 1.1 Installing Dashboard Software Dashboardxxx.exe Administration Rights Prerequisite Wizard
Omega Dashboard 1 PART 1 CONFIGURATION 1.1 Installing Dashboard Software Find the Dashboardxxx.exe in the accompanying CD or on the web. Double click that to install it. The setup process is typical to
HASP Troubleshooting Guide
HASP Troubleshooting Guide Corporate office: Trimble Geospatial Division 10368 Westmoor Drive Westminster, CO 80021 USA www.trimble.com Copyright and trademarks: 2005-2013, Trimble Navigation Limited.
NOC PS manual. Copyright Maxnet 2009 2015 All rights reserved. Page 1/45 NOC-PS Manuel EN version 1.3
NOC PS manual Copyright Maxnet 2009 2015 All rights reserved Page 1/45 Table of contents Installation...3 System requirements...3 Network setup...5 Installation under Vmware Vsphere...8 Installation under
ENTERPRISE LINUX SYSTEM ADMINISTRATION
ENTERPRISE LINUX SYSTEM ADMINISTRATION The GL250 is an in-depth course that explores installation, configuration and maintenance of Linux systems. The course focuses on issues universal to every workstation
Deploying Windows Streaming Media Servers NLB Cluster and metasan
Deploying Windows Streaming Media Servers NLB Cluster and metasan Introduction...................................................... 2 Objectives.......................................................
Hyper-V Server 2008 Setup and Configuration Tool Guide
Hyper-V Server 2008 Setup and Configuration Tool Guide Microsoft Corporation Published: October 2008 Author: Cynthia Nottingham Abstract This guide will help you set up and configure Microsoft Hyper-V
Online Backup Client User Manual Mac OS
Online Backup Client User Manual Mac OS 1. Product Information Product: Online Backup Client for Mac OS X Version: 4.1.7 1.1 System Requirements Operating System Mac OS X Leopard (10.5.0 and higher) (PPC
Online Backup Client User Manual Mac OS
Online Backup Client User Manual Mac OS 1. Product Information Product: Online Backup Client for Mac OS X Version: 4.1.7 1.1 System Requirements Operating System Mac OS X Leopard (10.5.0 and higher) (PPC
c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem
Start Here Follow these instructions to set up your router. Verify That Basic Requirements Are Met Assure that the following requirements are met: You have your broadband Internet service settings handy.
Network Connect Installation and Usage Guide
Network Connect Installation and Usage Guide I. Installing the Network Connect Client..2 II. Launching Network Connect from the Desktop.. 9 III. Launching Network Connect Pre-Windows Login 11 IV. Installing
