1 Product Book December 1, 2015 Control Panels l Alarm Systems Float Switches l Accessories Follow us on:

2 Ordering Information To assist us in delivering the exact product you want, please order by the seven digit part number or panel model number. If you require special features, such as additional cable length or special packaging, please call your customer service representative at DIAL-SJE ( ). SJE-Rhombus also manufactures Engineered Custom control panels. Please contact SJE-Rhombus customer service to request a custom panel quote at RHOMBUS ( ) or DIAL-SJE ( ). For additional information on our Blanket Agreement Program, Freight Paid Program, Return Policy or Payment Terms, please refer to the back side of your multiplier sheet, contact your factory representative or contact SJE-Rhombus customer service at DIAL- SJE ( ). SHIPPING YOUR ORDER Standard catalog items, depending on volume and options, are shipped within four (4) business days from receipt of order. Products marked with an asterisk (*) are Quick Ship products and normally ship within one (1) business day from receipt of order (as inventory allows) at no additional charge. Standard lead times may apply to orders combining Quick Ship and Non-Quick Ship products. SJE-Rhombus Build-A-Panel control panels ordered with multiple options and orders exceeding $10,000 may require up to ten (10) business days to ship. Large stocking panel orders or custom panel orders may require additional lead time of more than ten (10) business days. Next Day Air, Second Day Air and Three Day UPS Ground services are available. To receive these services you must place your order before 1:00 p.m. Central Time. SJE-Rhombus reserves the right to increase prices if transportation rates increase. SJE-Rhombus offers a Panel Express Program for expedited delivery on most control panels found in this catalog. Contact Customer Service for more information. PRODUCT RETURN Returned Materials Authorization (RMA) numbers must be assigned to products being returned for warranty claim. Control panel models IFS7, IFS8, SGS, 113, 123, 114, 124, 314, and 324; panels including option 10A ; panels including any non-catalog options; Build-A-Panel PLUS control panels; obsolete panels; and panels more than one year from the date of manufacture cannot be returned to SJE-Rhombus for restocking credit. Contact your customer service representative for instructions on returning a product for warranty. PRICING SUBJECT TO CHANGE WITHOUT NOTICE. Five-Year Limited Warranty* SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for five years* after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus. THE FIVE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJE-RHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. This warranty does not apply to: (a) damage due to lightning or conditions beyond the control of SJE-Rhombus; (b) defects or malfunctions resulting from units not installed, operated, or maintained in accordance with instructions provided, applicable local codes, ordinances, or accepted trade practices; (c) failures resulting from abuse, misuse, accident, or negligence; or (d) units repaired and/or modified without prior authorization from SJE-Rhombus. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-Rhombus, or such place as designated by SJE-Rhombus. Contact customer service at DIAL-SJE ( ) for a Return Materials Authorization number (RMA) on any product being returned for a warranty claim. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS SHALL NOT, IN ANY MATTER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. *Engineered custom panels carry a two-year limited warranty or as quoted. The pressure transducer included with the VARIOspeed products carries a one-year limited warranty. *The five-year limited warranty is effective on products manufactured after January 1, 2014.

3 CONTROL PANELS EZ Series EZ Series Single Phase Simplex (Demand/TD) 1 EZ Series Single Phase Duplex (Demand) 1 EZ Series In-Site CL Single Phase Simplex (Demand/TD) 1 EZ Series In-Site CL Single Phase Duplex (Demand/TD) 1 EZ Series Plugger 1 EZ Series Plugger Post 1 Installer Friendly Series IFS Single Phase Simplex (Demand/TD) 1 IFS Single Phase Duplex (Demand/TD) 1 IFS Three Phase Simplex (Demand/TD) 2 IFS Three Phase Duplex (Demand/TD) 2 IFS Single Phase Simplex Capacitor Start/Run 2 IFS Single Phase Duplex Capacitor Start/Run 2 IFS In-Site Single Phase Simplex (Demand/TD) 2 IFS In-Site Single Phase Duplex (Demand/TD) 2 Relay Logic Series RLS Simplex 2 RLS Duplex 2 Single Phase Simplex Model Model Model Single Phase Duplex Model Three Phase Simplex Model Three Phase Duplex Model Model 32S 3 Capacitor Start/Run Model SGS 3 Model Model Intrinsically Safe Model Model Model Model Intrinsically Safe Retro 4 Timed Dosing Model TD 4 Model DTD 4 Model PS 4 Drip Irrigation IFS Drip 5 Model DP 5 Plugger Products Model RP 5 JB Plugger 120V, 230V 5 Ultra Nator 5 PS Patrol 6 Water Well Model Oil Detection Products SJE Oil Spotter 6 SJE Oil Spotter Auto 6 Table of Contents Page # Page # Constant Pressure Controls VARIOspeed N1 7 VARIOspeed 3R 7 Starter Boxes Select Start 7 LIQUID LEVEL ALARMS Tank Alert AB 8 Tank Alert AB DUO 8 Tank Alert I 8 Tank Alert EZ 9 Tank Alert XT 10 Tank Alert DUO 10 Tank Alert 4X 10 LEVEL MONITORING C-Con Converter Box 11 SJE Level Monitor CL 11 PUMP SWITCHES SJE PumpMaster 12 SJE PumpMaster Plus 13 SJE PumpMaster SPDT 13 Double Float Master 14 SJE AmpMaster 14 SJE VerticalMaster 15 SJE MicroMaster AC/DC 15 SJE MicroMaster Plus WS 15 Junior Super Single 16 Super Single 16 Double Float 17 SJE HiTempMaster 17 CONTROL SWITCHES SJE SignalMaster 18 SJE SignalMaster SPDT 18 SJE MilliAmpMaster 19 SJE VerticalMaster II LC 19 Sensor Float 20 Sensor Float Mini 20 ACCESSORIES Junction Box 21 Control Panel Accessories 21 Cord Seals, Hub Assembly, Simplex Installation Kit, Duplex Installation Kit, Cable Connectors, Panel Mounting Post, Riser Mounting Kit, C-Level Sensor Simulator, and 4-20mA Simulator Float Accessories 22 Cable Clamp Assembly, Float Brackets, Pipe Mounting Bracket, Cable Weights, ETM w/piggy- Back Plug, Vertical Reed Switch, Anchor, & Chain Home Protection Products 22 Auto Dialer & Home Temperature Monitor PO Box 1708, Detroit Lakes, MN DIAL-SJE Fax customer.service@sjerhombus.com

4 Build-A-Panel Control Panel EZ SERIES - Single Phase, simplex or duplex, demand or timed dose, float controlled system for pump control and system monitoring. EZS1 Single Phase, Simplex, Timed Dose $ EZS2 Single Phase, Simplex, Demand Dose $ EZS4 Single Phase, Duplex, Demand Dose $ * EZS21W114H3A6A8AC10E15A17G $ See SJE-Rhombus Product Catalog for a complete list of options available for EZ Series panels. EZ SERIES IN-SITE CL - Single Phase, simplex or duplex, demand or timed dose, C-Level sensor controlled system for pump control and system monitoring. EZ SERIES PLUGGER - Provides convenient wiring connection for use with one single phase 120V or 230V pump in effluent and sewage installations. EZP1 120V Receptacle $ * EZP11W6C0H10EP17A $ EZP2 230V Receptacle $ See SJE-Rhombus Product Catalog for a complete list of options available for EZ Series Plugger panels. INSTALLER FRIENDLY SERIES - Single Phase, simplex or duplex, demand or timed dose, float controlled system for pump control and system monitoring. See SJE-Rhombus Product Catalog for a complete list of options available for EZ Series In-Site CL panels EZ Series In-Site CL data connection cable. Call SJE-Rhombus customer service for pricing. EZIS Single Phase, Simplex, Demand or Timed Dose w/c-level CL40 sensor $ EZID Single Phase, Duplex, Demand or Timed Dose w/c-level CL40 sensor $ EZ SERIES PLUGGER POST - Provides convenient wiring connection for use with one single phase 120V or 240V pump in effluent and sewage installations. Includes 34 mounting post EZ Plugger 120V with Post, Tank Alert AB, 15 SJE SignalMaster $ EZ Plugger 120V with Post, Tank Alert AB, 15 SJE SignalMaster, Elapsed Time Meter $ EZ Plugger 240V with Post, Tank Alert AB, 15 SJE SignalMaster $ EZ Plugger 240V with Post, Tank Alert AB, 15 SJE SignalMaster, Elapsed Time Meter $ IFS1 Single Phase, Simplex, Timed Dose $ IFS2 Single Phase, Simplex, Demand Dose $ * IFS21W114H8AC17G $ IFS3 Single Phase, Duplex, Timed Dose $ IFS4 Single Phase, Duplex, Demand Dose $ * IFS41W114H8AC17G $ See SJE-Rhombus Product Catalog for a complete list of options available for IFS panels. 1 s Effective December 1, 2015

5 INSTALLER FRIENDLY SERIES - Three Phase, simplex or duplex, demand or timed dose, float controlled system for pump control and system monitoring. INSTALLER FRIENDLY SERIES - Single Phase, simplex or duplex capacitor, demand dose float controlled system for pump control and system monitoring. INSTALLER FRIENDLY SERIES IN-SITE - Single Phase, simplex or duplex, demand or timed dose float controlled system for pump control, system monitoring, event logging and reporting. See SJE-Rhombus Product Catalog for a complete list of options available for IFS In-Site panels. IFI1 Single Phase, Simplex, Timed Dose $ IFI2 Single Phase, Simplex, Demand Dose $ IFI3 Single Phase, Duplex, Timed Dose $ IFI4 Single Phase, Duplex, Demand Dose $ MODEL Single phase, simplex motor contactor or pump switch control. Includes magnetic motor contactor. See SJE-Rhombus Product Catalog for a complete list of options available for 111 panels. 111 Single Phase, Simplex, Motor Contactor or Pump Switch Control $ MODEL Single phase, simplex pump switch control. See SJE-Rhombus Product Catalog for a complete list of options available for 115 panels. 115 Single Phase, Simplex, Pump Switch Control $ MODEL Single phase, simplex motor contactor control. See SJE-Rhombus Product Catalog for a complete list of options available for IFS panels. See SJE-Rhombus Product Catalog for a complete list of options available for IFS panels. IFS5 Three Phase, Simplex, Demand or Timed Dose $ IFS6 Three Phase, Duplex, Demand or Timed Dose $ IFS7 Single Phase, Simplex Capacitor, Demand Dose $ IFS8 Single Phase, Duplex Capacitor, Demand Dose $ RELAY LOGIC SERIES - Single Phase, simplex or duplex pump control RLS21W114H10AE15A17A - Includes (3) SJE SignalMaster control switches $ RLS21W114X10AE15A - No Floats $ RLS41W114H10E15A17A - Includes (3) SJE SignalMaster control switches $ RLS41W114X10E15A- No Floats $ Single Phase, Simplex, Motor Contactor Control $ * 1121W114H17A $ See SJE-Rhombus Product Catalog for a complete list of options available for 112 panels. s Effective December 1,

6 MODEL Single phase, duplex alternating pump control with override. 122 Single Phase, Duplex, Alternating Pump Control with Override $ * 1221W114H6A17A $ See SJE-Rhombus Product Catalog for a complete list of options available for 122 panels. MODEL Three phase, simplex motor contactor control. 312 Three Phase, Simplex, Motor Contactor Control $ See SJE-Rhombus Product Catalog for a complete list of options available for 312 panels. MODEL Three phase, duplex alternating pump control with override. 322 Three Phase, Duplex, Alternating Pump Control $ See SJE-Rhombus Product Catalog for a complete list of options available for 322 panels. MODEL SGS - Single phase, simplex sewage grinder motor contactor control. SGS Single Phase, Simplex, Sewage Grinder Motor Contactor Control $ Includes motor capacitor start/run components for certain pump models. Call factory at Rhombus ( ) to verify your pump model prior to quoting. See SJE-Rhombus Product Catalog for a complete list of options available for SGS panels. MODEL Single phase, simplex capacitor start/run pump control. See SJE-Rhombus Product Catalog for a complete list of options available for 113 panels. 113 Single Phase, Simplex, Capacitor Start/Run Pump Control $ MODEL Single phase, duplex capacitor start/run pump control with override. See SJE-Rhombus Product Catalog for a complete list of options available for 123 panels. MODEL 32S - Three phase, duplex alternating pump control with override. Simply add the appropriate overload modules S1S000X3A5AY6A8A10AE19X $ Overload Module FLA $ Overload Module FLA $ Overload Module FLA $ Lightning Arrestor $ Note: Each panel requires two overload modules. Field installation required. See SJE-Rhombus Product Catalog for a complete list of options available for 32S panels. 123 Single Phase, Duplex, Capacitor Start/Run Pump Control $ s Effective December 1, 2015

7 MODEL Single phase, simplex pump control with intrinsically safe circuits. See SJE-Rhombus Product Catalog for a complete list of options available for 114 panels. 114 Single Phase, Simplex, Intrinsically Safe $ MODEL Single phase, duplex alternating pump control with intrinsically safe circuits. See SJE-Rhombus Product Catalog for a complete list of options available for 124 panels. 124 Single Phase, Duplex, Alternating Intrinsically Safe $ MODEL Three phase, simplex pump control with intrinsically safe circuits. MODEL Three phase, duplex alternating pump control with intrinsically safe circuits. INTRINSICALLY SAFE RETRO - Single phase control panel with intrinsically safe circuits. See SJE-Rhombus Product Catalog for a complete list of options available for 314 panels. See SJE-Rhombus Product Catalog for a complete list of options available for 324 panels. 314 Three Phase, Simplex, Intrinsically Safe $ Three Phase, Duplex, Alternating Intrinsically Safe $ Intrinsically Safe Retro - 3 Channel $ Intrinsically Safe Retro - 4 Channel $ MODEL TD - Single phase, simplex timed dosing pump control. See SJE-Rhombus Product Catalog for a complete list of options available for TD panels. MODEL DTD - Single phase, duplex timed dosing control. See SJE-Rhombus Product Catalog for a complete list of options available for DTD panels. DTD Single Phase, Duplex, Timed Dose Pump Control $ MODEL PS - Single phase, duplex motor contactor control/programmable timed dosing control. See SJE-Rhombus Product Catalog for a complete list of options available for PS panels. TD Single Phase, Simplex, Timed Dose Pump Control $ PS Single Phase, Duplex, Timed Dose, Motor Contactor Control $ s Effective December 1,

8 INSTALLER FRIENDLY SERIES DRIP - Single phase, simplex subsurface touch pad drip irrigation for pump control and system monitoring Single Phase, Simplex, Subsurface Drip Irrigation - 120/208/240V $ Single Phase, Simplex, Subsurface Drip Irrigation w/ps - 120V $ Single Phase, Simplex, Subsurface Drip Irrigation w/ps - 120/208/240V $ MODEL DP1/DP2 - Single phase, simplex, PLC-based subsurface drip irrigation control Single Phase, Simplex, Subsurface Drip Irrigation - Programmable $ Single Phase, 4 Valve, Subsurface Drip Irrigation - Programmable $ MODEL RP - Single phase, simplex plug-in pump switch control. RP1 Single Phase, Simplex, 120V Plug-in Pump Switch Control $ RP2 Single Phase, Simplex, 208/240V Plug-in Pump Switch Control $ See SJE-Rhombus Product Catalog for a complete list of options available for RP panels. JB PLUGGER 120 VAC - Easy-to-install junction box provides convenient connection for use with one single phase pump in effluent and sewage chambers. 120 VAC * JBP no alarm or floats $ JBP Tank Alert AB & 15 SJE SignalMaster $ JBP Tank Alert AB & 15 SJE PumpMaster & 15 SJE SignalMaster $ JBP Tank Alert AB & 15 Double Float Master & 15 SJE SignalMaster $ JBP 20A, Tank Alert AB, 15 SJE PumpMaster & 15 SJE SignalMaster $ JBP 20A, Tank Alert AB, 15 Double Float Master & 15 SJE SignalMaster $ JB PLUGGER 230 VAC - Easy-to-install junction box provides convenient connection for use with one single phase pump in effluent and sewage chambers. 230 VAC JBP no alarm or floats $ JBP Tank Alert AB & 15 SJE SignalMaster $ JBP Tank Alert AB & 15 SJE PumpMaster & 15 SJE SignalMaster $ JBP Tank Alert AB & 15 Double Float Master & 15 SJE SignalMaster $ ULTRA NATOR - Controls two 120V single phase pumps using two receptacles for pump connections in duplex sump pump applications. No wiring needed * Ultra Nator & two 10 SJE MicroMaster $ Ultra Nator & two 10 SJE VerticalMaster II $ Ultra Nator & one 10 SJE VerticalMaster II & one 10 VRS $ Ultra Nator & two 20 SJE MicroMaster $ Ultra Nator & two 20 SJE VerticalMaster II $ s Effective December 1, 2015

9 PS PATROL - Provides convenient wiring connection and system monitoring for pump station applications. Model/PN MODEL Single phase, duplex alternating pump control with override for water well applications. PSP PS Patrol System base $ * PSP2 120V, 120V alarm, no pump switch; 20 SJE SignalMaster, with mounting post $ PSP2 120V, 120V alarm, no pump switch, 20A circuit breaker, with mounting post $ PSP2 120V, 120V alarm, ETM, 20 SJE SignalMaster, with mounting post $ PSP2 120V, 120V DUO alarm, ETM, 20 SJE SignalMaster & VRS, with mounting post $ PSP2 120V, no alarm, no pump switch; remote TAAB, 15 SJE SignalMaster, with mounting post $ Assembly Kit - Riser Extension coupling and Washers $62.50 See SJE-Rhombus Product Catalog for a complete list of options available for PS Patrol panels. 126 Single Phase, Duplex, Alternation Pump Control with Override $ See SJE-Rhombus Product Catalog for a complete list of options available for 126 panels. SJE OIL SPOTTER - Provides pump control and alarm notification of potentially threatening water and oil levels in simplex pumping applications. 120 VAC SJE Oil Spotter System (10ft) $ SJE Oil Spotter System (10ft) w/ Tank Alert AB $ SJE Oil Spotter System (50ft) w/ Tank Alert AB $ VAC SJE Oil Spotter 230V System (10ft) $ SJE Oil Spotter 230V System (10ft) w/ Tank Alert AB $ SJE OIL SPOTTER AUTO - Provides pump control, valve control, and alarm notification of potentially threatening water and oil levels in simplex pumping applications SJE Oil Spotter Auto System $ SJE Oil Spotter Auto System w/ Tank Alert AB $ s Effective December 1,

10 VARIOspeed N1 Control Panel - Variable Frequency Drive control panel in a NEMA1 enclosure. Model Voltage Output Amp HP Input Phase Output Phase VS N1 240V $ VS N1 240V $ VS N1 240V $ VS N1 240V $ VS N1 240V $ VS N1 240V $ VS N1 480V $ VS N1 480V $ VARIOspeed 3R Control Panel - Variable Frequency Drive control panel in a NEMA 3R enclosure. Model Voltage NEMA 3R Line/Load Reactors (N1 or 3R models). Model Output Amp Use With VFD Output Amperages LR N3R 7.0, 10.0, 16.5 $ LR N3R 31.8, 45.0 $ LR N3R 58.0 $ LR N3R 16.0 $ LR N3R 29.5 $ HP Input Phase Output Phase VS N3R 240V $ VS N3R 240V $ VS N3R 240V $ VS N3R 240V $ VS N3R 240V $ VS N3R 240V $ VS N3R 480V $ VS N3R 480V $ SELECT START Starter Boxes - Three phase 208/240/480 VAC starter boxes for motor control. Amps Thru Door Pump Disconnect Overload Module Starter Box, Three Phase, 208/240/480 VAC 3-12 No Yes $ Starter Box, Three Phase, 208/240/480 VAC 8-32 No Yes $ Starter Box, Three Phase, 208/240/480 VAC 3-12 Yes Yes $ Starter Box, Three Phase, 208/240/480 VAC 8-32 Yes Yes $ Starter Box, Three Phase, 208/240/480 VAC 3-32 No No* $ Starter Box, Three Phase, 208/240/480 VAC 3-32 Yes No* $ Starter Box, Three Phase, 575 VAC 3-12 No Yes $ Starter Box, Three Phase, 575 VAC 8-32 No Yes $ Starter Box, Three Phase, 575 VAC 3-12 Yes Yes $ Starter Box, Three Phase, 575 VAC 8-32 Yes Yes $ Starter Box, Three Phase, 575 VAC 3-32 No No* $ Starter Box, Three Phase, 575 VAC 3-32 Yes No* $ Overload Module, 120 VAC, 3-12 FLA $ Overload Module, 120 VAC, 8-32 FLA $ *Note: Starter Boxes ordered Without Overload Module will require Overload Module to be added in order to operate. 7 s Effective December 1, 2015

11 Liquid Level Alarm TANK ALERT AB - Easy-to-install liquid level alarm system with auto reset and battery backup features for indoor use * TA AB-01H (120 VAC w/15 SJE SignalMaster High Level) $ TA AB-01L (120 VAC w/15 SJE SignalMaster Low Level) $ TA AB-01H (120 VAC w/15 Sensor Float High Level) $ TA AB-01X (120 VAC no float) $ TA AB-01HAUX (120 VAC w/15 SJE SignalMaster High Level & Auxiliary Contracts) $ TA AB-01XAUX (120 VAC no float w/auxiliary Contacts) $98.92 OPTION AUX Alarm Auxiliary Contacts (factory installed option only) $18.25 H = High Level L = Low Level X = No Float MASTER CARTON holds 16 boxed units. CONTROL SWITCH OPTIONS: The Tank Alert AB alarm system comes standard with a 15ft SJE SignalMaster control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with no float to the price of the float switch. TANK ALERT AB DUO - Easy-to-install indoor alarm featuring two alarm inputs to monitor two level conditions. Includes auto reset and battery backup features TA AB DUO-01H (120 VAC w/15 SJE SignalMaster High Level) $ TA AB DUO-01HAUX(120 VAC w/15 SJE SignalMaster High Level w/auxiliary Contacts) $ H = High Level A = Auxiliary Contacts MASTER CARTON holds 16 boxed units. TANK ALERT I - Easy-to-install liquid level alarm system for indoor use. 120 VAC H (120 VAC w/15 SJE SignalMaster High Level) $ HSPKT (120 VAC w/15 SJE SignalMaster High Level) with splice kit $ H (120 VAC w/15 Sensor Float High Level) $ L (120 VAC w/15 Sensor Float Low Level) $ X (120 VAC no float) $ VAC H (230 VAC w/15 SJE SignalMaster High Level) $ H (230 VAC w/15 Sensor Float High Level) $ L (230 VAC w/15 Sensor Float Low Level) $ X (230 VAC no float) $ H = High Level L = Low Level X = No Float SPKT = Splice Kit MASTER CARTON holds 16 boxed units. CONTROL SWITCH OPTIONS: The Tank Alert I alarm system comes standard with a 15ft SJE SignalMaster control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with no float to the price of the float switch. s Effective December 1,

12 TANK ALERT EZ - Easy-to-install indoor/outdoor alarm system features a removable cover to provide greater access for easier field wiring. Two-color molded enclosure integrates red LED beacon. 120 VAC TAEZ-01H (120 VAC w/15 SJE SignalMaster High Level) $ TAEZ-01H (120 VAC w/15 SJE Sensor Float High Level) $ TAEZ-01X (120 VAC no float) $ TAEZ-01L (120 VAC w/15 SJE SignalMaster Low Level) $ TAEZ-01L (120 VAC w/15 SJE Sensor Float Low Level) $ VAC with Terminal Block * TAEZ-01HTB (120 VAC w/15 SJE SignalMaster High Level Terminal Block) $ TAEZ-01HTB (120 VAC w/15 Sensor Float High Level Terminal Block) $ TAEZ-01XTB (120 VAC no float w/terminal Block) $ TAEZ-01LTB (120 VAC w/15 SJE SignalMaster Low Level Terminal Block) $ TAEZ-01LTB (120 VAC w/15 Sensor Float Low Level Terminal Block) $ OPTIONPC 6 power cord with two RCC8 1/2 liquid-tight connectors $ VAC TAEZ-02H (240 VAC w/15 SJE SignalMaster High Level) $ TAEZ-02X (240 VAC no float) $ VAC with Terminal Block TAEZ-02HTB (240 VAC w/15 SJE SignalMaster High Level w/terminal Block) $ TAEZ-02XTB (240 VAC no float w/terminal Block) $ H = High Level L = Low Level X = No Float TB = Includes Terminal Block MASTER CARTON holds 12 boxed units. CONTROL SWITCH OPTIONS: The Tank Alert EZ alarm system comes standard with a 15ft SJE SignalMaster control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with no float to the price of the float switch. 9 s Effective December 1, 2015

13 TANK ALERT XT - Versatile, indoor or outdoor liquid level alarm system. STANDARD ALARM (120 VAC) TAXT-01H (120 VAC w/15 SJE SignalMaster High Level) $ TAXT-01L (120 VAC w/15 SJE SignalMaster Low Level) $ TAXT-01H (120 VAC w/15 Sensor Float High Level) $ TAXT-01L (120 VAC w/15 Sensor Float Low Level) $ TAXT-01X (120 VAC no float) $ STANDARD ALARM (120 VAC) with terminal block TAXT-01HAUXTB (120 VAC w/15 SJE SignalMaster High Level Aux Con TB) $ TAXT-01HTB (120 VAC w/15 SJE SignalMaster High Level TB) $ TAXT-01HTB (120 VAC w/15 Sensor Float High Level TB) $ TAXT-01LTB (120 VAC w/15 Sensor Float Low Level TB) $ TAXT-01XTB (120 VAC no float TB) $ TAXT-01HAUXTB (120 VAC w/15 SJE Sensor Float High Level Aux Con TB) $ STANDARD ALARM (120 VAC) with options TAXT-01HAUX (120 VAC w/15 Sensor Float High Level Auxiliary Contacts) $ TAXT-01HPC (120 VAC w/15 Sensor Float High Level Power Cord) $ OPTION AUX Auxiliary contacts (factory installed option only) $48.00 OPTION PC 6 power cord with two RCC8 1/2 liquid-tight connectors $25.50 H = High Level L = Low Level X = No Float TB = Includes Terminal Block PC = Power Cord AUX = Auxiliary Contacts MASTER CARTON holds 12 boxed units. CONTROL SWITCH OPTIONS: The Tank Alert XT alarm system comes standard with a 15ft SJE SignalMaster control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with no float to the price of the float switch. TANK ALERT DUO - Versatile, indoor or outdoor alarm system featuring two alarm inputs to monitor two level conditions TADUO-01H (120 VAC w/15 SJE SignalMaster ) $ TADUO-01H (120 VAC w/two 15 SJE SignalMaster ) $ H = High Level MASTER CARTON holds 4 boxed units. TANK ALERT 4X - Easy-to-install liquid level alarm system which has a NEMA 4X enclosure for indoor or outdoor use X-01HSGM (120 VAC w/15 SJE SignalMaster High Level) $ X-01LSGM (120 VAC w/15 SJE SignalMaster Low Level) $ X-01H (120 VAC w/15 Sensor Float High Level) $ X-01L (120 VAC w/15 Sensor Float Low Level) $ X-01X (120 VAC no float) $ OPTION AUX Auxiliary contacts (factory installed option only) $19.00 H = High Level L = Low Level X = No Float MASTER CARTON holds 12 boxed units. CONTROL SWITCH OPTIONS: The Tank Alert 4X alarm system comes standard with a 15ft SJE SignalMaster control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with no float to the price of the float switch. s Effective December 1,

14 Level Monitoring C-CON CONVERTER BOX - Converts any float-operated control panel to utilize the C-Level CL40 floatless sensor. 120 VAC C-Con converter box w/c-level CL40 sensor (4 foot vent tube and 20 foot cable) $ C-Con converter box w/c-level CL40 sensor (4 foot vent tube and 40 foot cable) $ C-Con converter box w/c-level CL40 sensor (8 foot vent tube and 20 foot cable) $ C-Con converter box w/c-level CL40 sensor (8 foot vent tube and 40 foot cable) $ C-Con converter box without C-Level CL40 sensor $ SJE LEVEL MONITOR CL - Monitors tank levels by utilizing the C-Level floatless sensor. 120 VAC SJE Level Monitor CL w/c-level CL40 sensor (4 foot vent tube & 20 foot cable) $ SJE Level Monitor CL w/c-level CL40 sensor (4 foot vent tube & 40 foot cable) $ SJE Level Monitor CL w/c-level CL40 sensor (4 foot vent tube & 80 foot cable) $ SJE Level Monitor CL w/c-level CL40 sensor (4 foot vent tube & 200 foot cable) $ SJE Level Monitor CL w/c-level CL100 sensor (10 foot vent tube & 20 foot cable) $ SJE Level Monitor CL w/c-level CL100 sensor (10 foot vent tube & 40 foot cable) $ SJE Level Monitor CL w/c-level CL100 sensor (10 foot vent tube & 80 foot cable) $ SJE Level Monitor CL w/c-level CL100 sensor (10 foot vent tube & 200 ft. cable) $ s Effective December 1, 2015

15 Pump Switch SJE PUMPMASTER pump switch - Mechanically activated, wide angle switch designed to control pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. PUMP DOWN PUMP UP PMD1WP PMU1WP $ PMD2WP PMU2WP $ PMDWOP PMUWOP $ * 15PMD1WP PMU1WP $ PMD2WP PMU2WP $ PMDWOP * 15PMUWOP $ PMD1WP-QF $ PMD1WP PMU1WP $ PMD2WP PMU2WP $ PMDWOP PMUWOP $ PMD1WP PMU1WP $ PMD2WP PMU2WP $ PMDWOP PMUWOP $67.71 D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug QF = Quick Fit NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. CABLE WEIGHT MOUNTING is also available. QUICK FIT piggy-back plug and float are separate to allow for quick fit installation. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. s Effective December 1,

16 SJE PUMPMASTER PLUS pump switch - Mechanically activated, wide angle switch designed to control pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC. PUMP DOWN PUMP UP PMPD1WP PMPU1WP $ PMPD2WP PMPU2WP $ PMPDWOP PMPUWOP $ * 15PMPD1WP PMPU1WP $ PMPD2WP PMPU2WP $ PMPDWOP PMPUWOP $ PMPD1WP-QF $ PMPD1WP PMPU1WP $ PMPD2WP PMPU2WP $ PMPDWOP PMPUWOP $ PMPD1WP PMPU1WP $ PMPD2WP PMPU2WP $ PMPDWOP PMPUWOP $91.17 D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug QF = Quick Fit NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. CABLE WEIGHT MOUNTING is also available. QUICK FIT piggy-back plug and float are separate to allow for quick fit installation. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. SJE PUMPMASTER SPDT pump switch - Mechanically activated, wide angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. PUMP DOWN OR PUMP UP without plug only PMSPDTPC $ PMSPDTWE $ PMSPDTPC $ PMSPDTWE $ PMSPDTPC $ PMSPDTWE $ PMSPDTPC $ PMSPDTWE $85.48 PC = Pipe Clamp WE = Weighted Externally Can be wired to work in either pump down (normally open) or pump up (normally closed) applications (Single Pole, Double Throw). NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. CABLE WEIGHT MOUNTING is also available. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. 13 s Effective December 1, 2015

17 DOUBLE FLOAT MASTER pump switch - Mechanically activated, wide angle switch designed to control pumps up to 15 FLA, 90 LRA, 120 VAC or 240 VAC. PUMP DOWN PUMP UP * 15DFMMD1WP DFMMU1WP $ DFMMD2WP DFMMU2WP $ DFMMD1WOP DFMMU1WOP $ DFMMD2WOP DFMMU2WOP $ DFMMD1WP DFMMU1WP $ DFMMD2WP DFMMU2WP $ DFMMD1WOP DFMMU1WOP $ DFMMD2WOP DFMMU2WOP $ DFMMD1WP DFMMU1WP $ DFMMD2WP DFMMU2WP $ DFMMD1WOP DFMMU1WOP $ DFMMD2WOP DFMMU2WOP $ D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: s are grouped by cable length measured in feet (15, 20, 30). PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. SJE AMPMASTER pump switch - Mechanically activated, wide angle 20 amp rated switch designed to control pumps up to 1 1/2 HP at 125 VAC and 3 HP at 250 VAC. PUMP DOWN ONLY without plug only AMDWOP $ AMDWOP $ AMDWOP $ AMDWOP $ D = Pump Down WOP = With Out Plug MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. s Effective December 1,

18 SJE VERTICALMASTER pump switch - Mechanically activated pump switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. PUMP DOWN ONLY * 10VM1WP $ VM2WP $ VMWOP $ VM1WP $ VM2WP $ VMWOP $ VM1WP $ VM2WP $ VMWOP $ VM1WP $ VM2WP $ VMWOP $ = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING BRACKET and HOSE CLAMP are standard. PACKAGING: Boxed - Standard SJE MICROMASTER AC/DC pump switch - Mechanically activated, wide angle switch designed for performance and dependability. PUMP DOWN PUMP UP MMDCDWOP MMDCUWOP $50.91 WOP = With Out Plug MOUNTING CLAMP is standard. PACKAGING: Bulk - Standard SJE MICROMASTER PLUS WS pump switch - Mechanically activated, wide angle switch designed to control pumps up to 1/2 HP at 125 VAC and 1 HP at 250 VAC. PUMP DOWN PUMP UP MMPD1WPWS MMPU1WPWS $ MMPD2WPWS MMPU2WPWS $ MMPDWOPWS MMPUWOPWS $ MMPD1WPWS MMPU1WPWS $ MMPD2WPWS MMPU2WPWS $ MMPDWOPWS MMPUWOPWS $ MMPD1WPWS MMPU1WPWS $ MMPD2WPWS MMPU2WPWS $ MMPDWOPWS MMPUWOPWS $ MMPD1WPWS MMPU1WPWS $ MMPD2WPWS MMPU2WPWS $ MMPDWOPWS MMPUWOPWS $65.22 D = Pump Down U = Pump Up 1 = 125VAC 2 = 250VAC WP = With Plug WOP = With Out Plug NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. CABLE WEIGHT MOUNTING is also available. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. 15 s Effective December 1, 2015

19 JUNIOR SUPER SINGLE pump switch - Mercury activated, wide angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. PUMP DOWN PUMP UP JSD1WP JSU1WP $ JSD2WP JSU2WP $ JSDWOP JSUWOP $ * 15JSD1WP JSU1WP $ JSD2WP JSU2WP $ JSDWOP JSUWOP $ JSD1WP JSU1WP $ JSD2WP JSU2WP $ JSDWOP JSUWOP $ JSD1WP JSU1WP $ JSD2WP JSU2WP $ JSDWOP JSUWOP $76.79 D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. SUPER SINGLE pump switch - Mercury activated, wide angle switch designed to control pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC. PUMP DOWN PUMP UP SSD1WP SSU1WP $ SSD2WP SSU2WP $ SSDWOP SSUWOP $ SSD1WP SSU1WP $ SSD2WP SSU2WP $ SSDWOP SSUWOP $ SSD1WP SSU1WP $ SSD2WP SSU2WP $ SSDWOP SSUWOP $ SSD1WP SSU1WP $ SSD2WP SSU2WP $ SSDWOP SSUWOP $ D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. s Effective December 1,

20 DOUBLE FLOAT pump switch - Mercury activated, wide angle switch designed to control pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC. PUMP DOWN PUMP UP * 15DFD1WP DFU1WP $ DFD2WP DFU2WP $ DFD1WOP DFU1WOP $ DFD2WOP DFU2WOP $ DFD1WP DFU1WP $ DFD2WP DFU2WP $ DFD1WOP DFU1WOP $ DFD2WOP DFU2WOP $ DFD1WP DFU1WP $ DFD2WP DFU2WP $ DFD1WOP DFU1WOP $ DFD2WOP DFU2WOP $ D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: s are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. SJE HI TEMP MASTER pump switch - Mechanically-activated, wide-angle switch specifically designed for performance and dependability in high temperature sump applications up to 200 F (93 C) HTMD1WP $ HTMD2WP $ HTMDWOP $ HTMD1WP $ HTMD2WP $ HTMDWOP $ HTMD1WP $ HTMD2WP $ HTMDWOP $87.98 D = Pump Down 1 = 125VAC 2 = 250VAC WP = With Plug WOP = With Out Plug NOTE: s are grouped by cable length measured in feet (10, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 20 from list price. 17 s Effective December 1, 2015

21 Control Switch SJE SIGNALMASTER control switch - Mechanically activated, narrow angle float switch designed to activate pump control panels and alarms. NORMALLY OPEN NORMALLY CLOSED SGMPCNO SGMPCNC $ SGMWENO SGMWENC $ SGMPCNO SGMPCNC $ SGMWENO SGMWENC $ * 20SGMPCNO SGMPCNC $ SGMWENO SGMWENC $ SGMPCNO SGMPCNC $ SGMWENO SGMWENC $57.33 PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. SJE SIGNALMASTER SPDT pump switch - Mechanically activated, narrow angle float switch designed to activate pump control panels and alarms. NORMALLY OPEN or NORMALLY CLOSED SGMSPDTPC $ SGMSPDTWE $ SGMSPDTPC $ SGMSPDTWE $ SGMSPDTPC $ SGMSPDTWE $ SGMSPDTPC $ SGMSPDTWE $65.01 PC = Pipe Clamp WE = Weighted Externally Can be wired to work in either pump down (normally open) or pump up (normally closed) applications (Single Pole, Double Throw). NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). FOR NO MOUNTING deduct 60 from the mounting clamp list price. CABLE WEIGHT MOUNTING is also available. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. s Effective December 1,

22 SJE MILLIAMPMASTER control switch - Mechanically activated control switch designed to activate low current control panels and alarms. NARROW ANGLE VERSONS NORMALLY OPEN NORMALLY CLOSED MANPCNO MANPCNC $ MANWENO MANWENC $ MANPCNO MANPCNC $ MANWENO MANWENC $ MANPCNO MANPCNC $ MANWENO MANWENC $ MANPCNO MANPCNC $ MANWENO MANWENC $59.86 WIDE ANGLE VERSONS NORMALLY OPEN NORMALLY CLOSED MAPCNO MAPCNC $ MAWENO MAWENC $ MAPCNO MAPCNC $ MAWENO MAWENC $ MAPCNO MAPCNC $ MAWENO MAWENC $ MAPCNO MAPCNC $ MAWENO MAWENC $59.86 PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). FOR NO MOUNTING deduct 60 from the mounting clamp list price. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. SJE VERTICALMASTER II LC control switch - Mechanically-activated control switch designed to activate low current control panels and alarms. NORMALLY OPEN VMIILC BOX $ VMIILC BOX $54.94 MOUNTING BRACKET and HOSE CLAMP are standard. PACKAGING: Boxed - Standard. 19 s Effective December 1, 2015

23 SENSOR FLOAT control switch - Mercury activated, narrow angle float switch designed to activate pump control panels and alarms. NORMALLY OPEN NORMALLY CLOSED PCNO PCNC $ SWINO SWINC $ SWENO SWENC $ * 15PCNO PCNC $ SWINO SWINC $ SWENO SWENC $ PCNO PCNC $ SWINO SWINC $ SWENO SWENC $ PCNO PCNC $ SWINO SWINC $ SWENO SWENC $70.68 PC = Pipe Clamp WI = Weighted Internally WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). FOR NO MOUNTING deduct 60 from the mounting clamp list price. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. SENSOR FLOAT MINI control switch - Mercury activated, narrow angle float switch designed to activate pump control panels and alarms. NORMALLY OPEN NORMALLY CLOSED MPCNO MPCNC $ MWENO MWENC $ MPCNO MPCNC $ MWENO MWENC $ MPCNO MPCNC $ MWENO MWENC $ MPCNO MPCNC $ MWENO MWENC $64.41 PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: s are grouped by cable length measured in feet (10, 15, 20, 30). FOR NO MOUNTING deduct 60 from the mounting clamp list price. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. s Effective December 1,

24 Accessories JUNCTION BOXES - Seals electrical connections from moisture and other elements JB444 (no connectors or hub installed) $ JB H-3R8 Simplex $ JB H-4R8 Simplex $ JB664 (no connectors or hub installed) $ JB H-4R8 Simplex (small HP pump) $ JB664-2H-5R8 Duplex (small HP pump) $ JB H-3R8-1R12 Simplex (large HP pump) $ JB664-2H-3R8-2R12 Duplex (large HP pump) $ JB884 (no connectors or hub installed) $ NOTE: s grouped by enclosure size. 444 = 4 x 4 x 4, 664 = 6 x 6 x 4, 884 = 8 x 8 x 4. All enclosure dimensions are in inches. Number before R8 or R12 equals the number of connectors of that size installed. 1.5H = 1 1/2 HUB, 2H = 2 HUB. R8 = RCC8, R12 = RCC12. Small HP pump = Pump cable 18/2 to 14/3 gauge. Large HP pump = Pump cable 14/4 to 10/3 gauge. CONTROL PANEL ACCESSORIES - Cord Seals, Hub Assembly, Simplex Installation Kit, Duplex Installation Kit, Cable Connectors, Panel Mounting Post, Riser Mounting Kit, C-Level Sensor Simulator, and 4-20mA Simulator Cable Cord Seal $ Cable Cord Seal $ /2 inch Round Cable Connector (RCC-8) $ /4 inch Round Cable Connector (RCC-12) $ inch Round Cable Connector (RCC-16) $ /2 inch Flat UF Cable Connector (UFCC-8) $ /4 inch Flat UF Cable Connector (UFCC-12) $ /4 inch Hub Assembly $ inch Hub Assembly $ inch Hub Assembly $ inch Hub Assembly $ inch Hub Assembly $ Panel Mounting Post $ Riser Mounting Kit $ Simplex Installation Kit $ Duplex Installation Kit $ C-Level Sensor Simulator $ mA Simulator $ s Effective December 1, 2015

25 FLOAT ACCESSORIES - Cord Seal, Cable Clamp Assembly, Float Brackets, Pipe Mounting Bracket, Cable Connectors, Hub Assembly, Cable Weights, Elapsed Time Meter w/piggy-back Plug, Post Junction Box, Vertical Reed Switch, Anchor, and Chain & 16 Gauge Cable Clamp Assembly $ Gauge Cable Clamp Assembly $ Gauge Cable Clamp Assembly $ * 4 Float Bracket with Mounting Device $ Float Bracket without Mounting Device $ Float Bracket with Mounting Device $ Float Bracket without Mounting Device $ Float Bracket Mounting Device $ Pipe Mounting Bracket $ Cable Weight $ Cable Weight Mini $ Elapsed Time Meter w/120v Piggy-Back Plug $ Elapsed Time Meter w/230v Piggy-Back Plug $ foot Vertical Reed Switch 120V Bulk $ foot Vertical Reed Switch 120V Bulk $ lb. Mushroom Anchor $ /8 inch Chain $9.22 per ft. HOME PROTECTION PRODUCTS - Easy-to-install home monitoring products that provide notification of conditions such as threatening liquid level and low temperature Auto Dialer $ Home Temperature Monitor $ Auto Dialer w/home Temperature Monitor $ s Effective December 1,

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13 CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

0150506194 C Limited 2nd through 5th Year Functional Parts Warranty During the 2nd through 5th year,haier will provide functional parts which prove to be defective due to workmanship

More information

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual 255379 Rev. D0 1015 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

INSTANT HOT WATER RECIRCULATING SYSTEM

INSTANT HOT WATER RECIRCULATING SYSTEM INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

Self Monitoring Power Supply (BPSM)

Self Monitoring Power Supply (BPSM) LIFETIME REPLACEMENT WARRANTY Self Monitoring Power Supply (BPSM) Application - When interfacing with a fire alarm system where the system s auxiliary relay cannot handle the full current potential of

More information

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

InHome Water Leak Detection Package

InHome Water Leak Detection Package InHome Water Leak Detection Package For Model Numbers ILD10A-L and ILD10A-B Installation Guide / Wiring Diagram For Creating Water Leak Detection-based Events with Line-Powered or Battery-Powered Sensors

More information

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product. Owner s Manual 1 Dear Customer, Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully. User Memo: Date of purchase: Dealer name: Dealer address:

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

ETZGAR CONVEYOR COMPANY Controls Section v12.05

ETZGAR CONVEYOR COMPANY Controls Section v12.05 Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed

More information

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party

More information

CHAPTER 1. GETTING STARTED... 1

CHAPTER 1. GETTING STARTED... 1 REV. 01-2014 TABLE OF CONTENTS LIMITATION OF LIABILITY CHAPTER 1. GETTING STARTED... 1 1.1 Introduction... 1 1.2 System Descriptions... 1 1.3 System Applications... 1 1.4 System Specifications... 1 1.5

More information

For Models #6-5001, #6-7501, #10-7501 & #10-12K1

For Models #6-5001, #6-7501, #10-7501 & #10-12K1 EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE

More information

Automatic Phone-Out Home Monitoring Systems

Automatic Phone-Out Home Monitoring Systems Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are

More information

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC BAYweb Remote Model BW-BCU5 Owner's Manual Copyright 2009-2010 Bay Controls, LLC Part Number: BW-BCU5DOC Revision: 0.2 April 18, 2010 BAYweb is a

More information

MODEL 300505 INSTALLATION INSTRUCTIONS

MODEL 300505 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

How To Size A Stenner Pump

How To Size A Stenner Pump Metering Pumps Manufactured Since 1957 PCM Series Pump Control Module INSTALLATION AND MAINTENANCE MANUAL Table of Contents WarrantyandServicePolicy...3 Safety Information...............................................

More information

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop

More information

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS CONTENTS Parts List... 2 Parts Diagram... 2 Helpful Hints... 3 Installation... 4 Operation and Troubleshooting Guide... 6 Warranty Information... 8 Form #3132,

More information

SingleNet Single Cable Control System

SingleNet Single Cable Control System Single Cable Control System Economical, Reliable and Expandable Two-Wire Single Cable System DRIP/MICRO IRRIGATION PRODUCTS Single Cable Control System System Manager or Irrigation Controller Controls

More information

DCX300 - DCX400 - DCX600

DCX300 - DCX400 - DCX600 Ph: 541-476-3565 Fax: 541-476-3566 DCX300 - DCX400 - DCX SEPARATELY EXCITED DC MOTOR CONROLLERS Alltrax motor controllers are designed to work with various golf cars from different manufacturers. Use the

More information

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Model 53603. Owner s Manual. Español - P. 19 Français - P. 39

Model 53603. Owner s Manual. Español - P. 19 Français - P. 39 Model 53603 Owner s Manual Español - P. 19 Français - P. 39 Table of Contents I. Introduction............................ 1 Sample Watering Plan.......................... 1 II. Installation...........................

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

Industrial Ringdown/Autodialer Telephone SCR Series

Industrial Ringdown/Autodialer Telephone SCR Series Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS)

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS) SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS) PART 1: GENERAL 1.01 SCOPE OF WORK A. Under this section of the specifications, the contractor shall furnish and install a shop-fabricated 4X4 Dispersal

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This

More information

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation

More information

Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES

Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES Installation Instructions Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES Read This Book This book has important information

More information

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions Instructions Instructions The Parts in this section of the manual are listed by Item Number, Part Number, Description and Quantity. The Item Numbers are in a circle with an arrow pointing to the specific

More information

Voice Dialer System & Power Monitor VD-5100-SM

Voice Dialer System & Power Monitor VD-5100-SM Custom Design Innovative Technologies in Custom Electronic Design & Manufacuturing General Description The VD-5100-SM Voice Dialer monitors an external dry contact such as a motion detector and power status.

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

CutMaster 102. 6.04 Major External Replacement Parts

CutMaster 102. 6.04 Major External Replacement Parts CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #

More information

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0

More information

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C R WARNING risk of electric shock.

More information

Leak Detection System

Leak Detection System Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE

More information

AIR CONDITIONING UNITS

AIR CONDITIONING UNITS A/C Systems Warranty Manual AIR CONDITIONING UNITS Revision 10/2014 Doc. P/N: 10000033E AP 10000033E 10/2014 Contents: I. Spheros North America Warranty Statement II. Warranty Manual 1-7 Purpose of this

More information

i ChatterBox! Motorcycle Security

i ChatterBox! Motorcycle Security i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:

More information

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142

More information

MODEL #12006. Introduction

MODEL #12006. Introduction THE ORIGINAL PECO POWER SPRAYER PECO OWNER S MANUAL MODEL #12006 (Q0080) Revised: 1/8/2014 PECO POWER SPRAYER MODEL #12006 TABLE OF CONTENTS SECTION PAGE SECTION PAGE INTRODUCTION - - - - - - - - - - -

More information

WGL20, WGL20H, WGL20F Grinder Pumps

WGL20, WGL20H, WGL20F Grinder Pumps WGL20, WGL20H, WGL20F Grinder Pumps Installation and Service Manual 2012 Pentair Pump Group, Inc. 23833A032 03/12 Thank you for purchasing your Myers Pump. To help ensure years of trouble-free operation,

More information

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,

More information

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.

More information

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions

More information

T-Series Air Conditioner T62 Model

T-Series Air Conditioner T62 Model INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

INSTRUCTION MANUAL MODEL PCD-88

INSTRUCTION MANUAL MODEL PCD-88 INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:

More information

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

MS900AC-B-LS User Information

MS900AC-B-LS User Information MS900AC-B-LS User Information MS900-R-AC-B-LS systems equipped with MR900 Micro Receiver are Receive-Only. MS900-X-AC-B-LS systems equipped with MX900 Micro Transceiver will Send and Receive. The model

More information

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the

More information

Unattended Answering Device Instruction Manual

Unattended Answering Device Instruction Manual Model 3137B Unattended Answering Device Instruction Manual Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax: 585-765-9330 monroe-electronics.com Printed in USA Copyright

More information

Automation & Sanitization REPLACEMENT PARTS

Automation & Sanitization REPLACEMENT PARTS & Sanitization PROLOGIC GLX-PCB-PRO Main PCB, ProLogic GLX-PL-LOC-P-4 Display, Local, ProLogic, P-4 GLX-PL-LOC-PS4 Display, Local, ProLogic, PS-4 GLX-PL-LOC-PS8 Display, Local, ProLogic, PS-8 GLX-PL-LOC-PS16

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind www.toshiba.com/ind 2011 Toshiba International Corporation Rev. 110504 Industrial Catalog 2011 13131 W. Little York Road Houston, TX 77041 Tel: 713-466-0277 Fax: 713-466-8773 US: 800-231-1412 Canada: 800-872-2792

More information

Installation and Operation Guide PD4600 Series Converter Replacement

Installation and Operation Guide PD4600 Series Converter Replacement Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your

More information

A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE

A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE The U.L.C. Listed C142.14-03 Cubet container provides a unique solution to storage and dispensing fluids. The Cubet s logical and integrated design allows

More information

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.065 FM1469 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies

More information

GL-235 Solar Pool Controller

GL-235 Solar Pool Controller GL-235 Solar Pool Controller Installation & Operation Manual G LDLINE CON TROLS www.goldlinecontrols.com Description The GL-235 is a differential temperature control for solar heating of pools, spas, and

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Copyrights 2010 Victron Energy B.V. All Rights Reserved Manual EN 1 Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For conditions of use and permission

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS ddcwp_manual_gb_revisions.ai 10/23/06 Page 1 Date: Station 1 2 3 4 5 6 7 8 CUSTOM WATERING PLAN 3 Program Controller Description Program A Program B Program C Duration Duration Duration DDC WP Series Waterproof

More information