1 Guide Intel Centrino with vpro Technology Intel Core 2 Processor with vpro Technology Intel Core i5 vpro Processor Intel Core i7 vpro Processor Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 For Use With Intel vpro Processor Technology and Microsoft* System Center Configuration Manager 2007 SP2 Based on Intel Active Management Technology Version May 2010
2 ii
3 Contents Executive Summary... 1 Microsoft Resources for ConfigMgr Section 1.0: Lab Network Design and Layout... 3 Section 2.0: Overview of the Implementation Process... 4 Section 2.1: High Level Steps... 4 Section 2.2: Installation and Configuration Process Flowchart... 5 Section 2.3: Summary of Prerequisites Required for OOB Management... 7 Section 2.4: Check for the latest Microsoft Hot Fixes... 7 Section 3.0: Configure Active Directory for Out of Band Management... 8 Section 4.0: Configure Enterprise PKI Certificate Server Section 5.0: Install ConfigMgr 2007 SP Section 6.0: Install Out of Band Management Service Point Section 6.1: Configure Out of Band Management Service Point on ConfigMgr Section 6.2: Configure Network Discovery for Management Controllers Section 6.3: Configure New Site Boundary Section 7.0: ConfigMgr 2007 Collection Setup Section 7.1: Create Intel AMT Unprovisioned Collection Section 7.2: Configure Intel AMT Collection to Automatically Provision Intel AMT Devices Section 8.0: ConfigMgr 2007 Agent Installation and In-Band Provisioning Section 9.0: Legacy Provisioning Section 9.1: Intel WS-MAN Translator Installation and Configuration Section 9.2: ConfigMgr Import Wizard for PSK Provisioning with Intel WS-MAN Translator Section 10.0: Helpful ConfigMgr 2007 Logs for Troubleshooting Section 10.1: Server Logs Section 10.2: Client Logs Section 11.0: Resources Appendix: Code Example for GetProvisioningData Script iii
4 iv
5 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Executive Summary This document describes the process to set up the Out of Band Management (OOB) capabilities within Microsoft* System Center Configuration Manager 2007 (ConfigMgr 2007) Service Pack 2 (SP2). It is not intended to replace the detailed documentation in the ConfigMgr 2007 SP2 help file. Intel highly recommends that all readers reference Microsoft s TechNet information for complete ConfigMgr 2007 information (Uhttp://technet.microsoft.com/en-us/library/bb735860(TechNet.10).aspxU). This document is intended to condense the necessary information to the least amount of material to make a quick start guide for readers to enable Out of Band Management for Intel vpro technology based systems. The document uses a lab environment setting as an example to demonstrate the overall ConfigMgr 2007 OOB setup and configuration process. ConfigMgr 2007 SP2 provides native Intel vpro technology support of Intel Active Management Technology (Intel AMT) firmware version and later. Contact your OEMs (see OEMs web site) for the latest Intel AMT Firmware releases. For legacy Intel vpro technology-based systems (Intel AMT firmware version lower than 3.2.1), you will need to install Intel WS-Man Translator on your ConfigMgr 2007 OOB management console system. Setup and configuration information is provided in this guide in Section 9.1: Intel WS-MAN Translator Installation and Configuration on page 63 to support for these versions of Intel vpro technology. This document is posted on the Intel vpro Expert Center (Uhttp://communities.intel.com/community/openportit/vproexpert/microsoft-vpro?view=documentsU) and updated periodically. Use the Intel vpro Expert Center contact link to provide feedback on this document. Microsoft Resources for ConfigMgr 2007 The Microsoft System Center Configuration Manager 2007 TechNet article shown below is an excellent resource to use when building your production environment. Information specific to Intel vpro technology is located under Out of Band Manage Configuration Manager 2007 SP1 and Later. (Uhttp://technet.microsoft.com/en-us/library/cc aspxU). 1
6 2
7 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Section 1.0: Lab Network Design and Layout As mentioned previously, an example of a lab setup is used throughout this document. This section briefly describes the lab environment referred to in the examples throughout the document. Your environment (lab or production environment) may vary and need additional steps to properly configure your environment to work with Intel vpro systems. Lab design: The example lab uses a virtualized environment within one server. Five separate virtual images were installed on this one server system, each running its own Windows 2008 Enterprise Server R2 with all of the latest service packs and software releases from Microsoft Windows Update (as of 4/1/2010). The five VMs are: Domain Controller (DHCP and DNS) Enterprise Root Certificate Authority Subordinate Certificate Authority SQL Server 2008 (Database for ConfigMgr 2007 SP2) ConfigMgr 2007 SP2 with the OOB Management Service Point The virtual images were separated for different functions rather than running everything on a single system as this emulates a realistic customer environment. Additionally, all Intel vpro technology-based lab systems were joined to this single Domain to perform provisioning and OOB management capabilities. The lab environment is pictured in the following illustration. 3
8 Section 2.0: Overview of the Implementation Process The following is a high level overview of the process to implement Microsoft* ConfigMgr 2007 OOB management of Intel vpro technology-based client systems. These high level steps are discussed in more detail in the subsequent sections of this guide. Related sections with detailed steps are referenced in each high-level step. Section 2.1: High Level Steps 1. Configure the networking and IT infrastructure (open the required firewall and router ports for management traffic, configure the network domain for the ConfigMgr 2007 OOB Service Point to the same domain as the Intel vpro technology-based systems, etc.). 2. Configure Microsoft* Active Directory. 3. Configure a Certificate Server. 4. Install ConfigMgr 2007 SP2, as well as all required hot fixes. 5. Install and configure the ConfigMgr 2007 OOB Service Point. 6. Set up a ConfigMgr 2007 Collection of Intel vpro technology based systems for In-Band provisioning. 7. Discover the unprovisioned Intel vpro technology-based clients in ConfigMgr 2007 (part of Collection Setup process). 8. Decide whether to use agent-based provisioning (recommended for clients with Intel vpro technology firmware version or later) or bare metal Remote Configuration (required for clients with Intel vpro technology firmware version less than 3.2.1). Note that if you have a mix of clients, you may need to use agent-based provisioning for some clients and Remote Configuration for others, depending on the firmware version of the clients. 9. For clients with Intel vpro technology firmware version or later, install the ConfigMgr 2007 agent on each client (Section 8.0: ConfigMgr 2007 Agent Installation and In-Band Provisioning, page 56). Once the agent is installed, the ConfigMgr 2007 OOB Service Point will automatically begin provisioning the client. If you do not have any clients with Intel vpro technology firmware version less than 3.2.1, skip to step 14 below. 10. For clients with Intel vpro technology firmware version less than 3.2.1, or if you choose not to install the ConfigMgr 2007 client agent and instead use Remote Configuration with firmware version clients, record each client s provisioning data (hostname, UUID, and FQDN) and enter that data in the ConfigMgr 2007 Import Wizard. 11. For Remote Configuration without installing the ConfigMgr client agent on clients having Intel vpro technology firmware version or later, once you have imported the client provisioning data into ConfigMgr, the clients will automatically be provisioned by the ConfigMgr OOB Service Point once you connect them to the network and boot them to the Windows OS. Skip to step 14 below. 12. For clients with Intel vpro technology firmware version less than 3.2.1, you MUST install the Intel WS-MAN translator on the same server system as the ConfigMgr 2007 OOB Service Point. 13. For clients with Intel vpro technology firmware version less than 3.2.1, manually enter a Pre-shared Key (PSK), also referred to as a PID-PPS pair, into each client s Intel Active Management Technology (Intel AMT) configuration using the Intel Management Engine BIOS Extension (Intel MEBx). Once the PSK has been entered, exit the Intel MEBx and reboot the client to the Windows OS; the client will automatically be provisioned by the ConfigMgr OOB Service Point. 4
9 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 14. Verify that the required drivers are installed on the Intel vpro technology-based clients. 15. Test the ConfigMgr 2007 OOB management functionality with the Intel vpro technology based clients. Checklist: Uhttp://technet.microsoft.com/en-us/library/cc161943(TechNet.10).aspxU Prerequisites: Uhttp://technet.microsoft.com/en-us/library/cc161785(TechNet.10).aspxU Section 2.2: Installation and Configuration Process Flowchart The following flowchart is intended to provide a visual map through the installation and configuration process, to illustrate the various implementation paths available to you depending on the version of Intel vpro technology firmware you are working with and other installation decisions. The steps shown in green represent the recommended path through the process for Intel vpro technology based clients with firmware version or higher. The steps and terminology in the flowchart are explained in detail in the subsequent sections of this guide. 5
10 6
11 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Section 2.3: Summary of Prerequisites Required for OOB Management The list below describes the necessary client, server, and infrastructure elements required in order to manage your Intel vpro technology-based systems Out-of-Band using Microsoft Configuration Manager 2007 SP2. The high level steps in Section 2.1 above (and the corresponding detailed steps in the subsequent sections of this guide) are the process by which to achieve the OOB management prerequisites listed below. Note: The reader is presumed to be familiar with setting up some of the prerequisites below, such as configuring the clients on the same network domain as the OOB Service Point server and setting certain firewall and networking ports open for management traffic. Prerequisites specific to Intel vpro technology and Microsoft ConfigMgr 2007 are discussed in detail in the remainder of this guide. Enterprise Certificate Authority to issue Web Server certificates to each Intel vpro technology-based system for encrypted communications with ConfigMgr 2007 SP2 Management Console (Standalone CA is insufficient) Active Directory OU to store Intel AMT objects for each Intel vpro technology based system that will be managed OOB ConfigMgr 2007 SP2 Out of Band Service Point installed and configured to support Intel vpro technology based systems Windows Remote Management (WinRM) installed on each ConfigMgr 2007 server 3 rd Party Remote Configuration Certificate on each OOB Service Point to provision Intel vpro technology-based systems (VeriSign, GoDaddy, Comodo, and Starfield have pre-installed hashes in the Intel AMT firmware) Optionally you can generate your own Provisioning Certificate from your Enterprise CA. However, this requires you to manually enter the CA hash into the Intel MEBx of Intel AMT Configure OOB network discovery of Intel vpro technology based systems (optional step but used in this lab) Intel vpro technology and firmware of or higher for native support from ConfigMgr 2007 SP2 Intel HECI Driver installed on the client OS (see OEM for latest driver) Configuration Manager Client Agent installed on each Intel vpro system to initiate the provisioning process (there are alternative methods available in the help file but this is the most effective and easiest method) Intel vpro technology based systems joined to the same domain as the OOB Service point provisioning and managing these devices Open Intel vpro technology related network ports on routers and firewalls: Provisioning Port; and through OOB Management Ports Section 2.4: Check for the latest Microsoft Hot Fixes Verify that all the latest hot fixes for Microsoft Server 2008, Microsoft Configuration Manager 2007 SP2, Microsoft Internet Explorer, and Microsoft SQL Server have been applied. Uhttp://support.microsoft.com/U 7
12 Section 3.0: Configure Active Directory for Out of Band Management Uhttp://technet.microsoft.com/en-us/library/cc161814(TechNet.10).aspxU Active Directory Schema extensions are not required for Intel AMT OOB Management functionality but Microsoft recommends applying the schema extensions for other non-related Intel vpro technology capabilities. If do not extend your AD with the supplied ConfigMgr 2007 Schema extension and configure your environment to publish ConfigMgr 2007 related components to the AD per Microsoft s instructions, you will need to update your WINS environment to allow for the ConfigMgr 2007 Agent to auto-discover your ConfigMgr 2007 Site Server (see Microsoft TechNet for details: Uhttp://technet.microsoft.com/enus/library/bb633121(TechNet.10).aspxU). However, the Active Directory must have two items configured for ConfigMgr 2007 to manage Intel vpro technology based systems. Create the Active Directory OU container in the domain for each Intel AMT device Configure security permissions on the container for ConfigMgr 2007 to generate an object for each Intel AMT device ConfigMgr 2007 SP2 will publish an Intel AMT object into a specific OU for each Intel vpro technology-based system that is provisioned by the OOB Management Service Point. This is a different object than the computer object that hosts the computer account in the domain. Also, Intel vpro technology-based clients must belong to the same AD Forest as the OOB Service Point. The following list provides the required steps to create this Intel AMT specific OU and provide the necessary rights for ConfigMgr 2007 server to create this object during the provisioning phase. Later, you will configure the OOB Management Server Point to use this object. This section illustrates the procedure described in the following Microsoft* TechNet article: How to Prepare Active Directory Domain Services for Out of Band Management (Uhttp://technet.microsoft.com/en-us/library/cc161814(TechNet.10).aspxU ). Click Start > Programs > Administrator Tools > Active Directory Users and Computers Note: Under the View menu option, ensure Advanced Features is checked Right Click on vprodemo.com > New > Group 8
13 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the New Object - Group dialog box, type ConfigMgr Primary Site Servers Click OK In the Active Directory Users and Computers, right-click the ConfigMgr Primary Site Servers Group and select Properties 9
14 In the ConfigMgr Primary Site Servers Properties window, select the Members tab and click Add Add the MSSCCM server and click OK (make sure you click the Object Types button and check Computers to find the SCCM Computer Account) Click OK to close the Properties window Note: Your ConfigMgr server is now a member of your ConfigMgr Primary Site Servers Group and will be used later for applying security rights to AD OUs and Certificate Templates. Note: Make sure you have not started up the ConfigMgr server image while setting up this server security setting. If you have the ConfigMgr server running, please shutdown now. 10
15 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Click Start > All Programs > Administrator Tools > Active Directory Users and Computers Note: Under the View menu option, ensure Advanced Features is checked Right Click on vprodemo.com > New > Organizational Unit In the New Object - Organizational Unit dialog box, type Out of Band Management Controllers click OK 11
16 Right-click Out of Band Management Controllers OU and click Properties Select the Security tab Click Add 12
17 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Select the ConfigMgr 2007 primary site server account (ConfigMgr Primary Site Servers is the name in this example) Note: you will need to click Object Types to add Computer Objects to find the server account Click OK after adding the ConfigMgrPrimary Site Server Account With the ConfigMgr Primary Site Servers Account selected, check Allow Full Control Click Advanced 13
18 Highlight ConfigMgr Primary Site Servers Account, and click Edit In the Apply onto drop down, select this object and all child objects. Click OK three times to close all windows 14
19 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Create RADIUS Security Group for AMT devices (if you use 802.1x) Click Start > Programs > Administrator Tools > Active Directory Users and Computers Expand vprodemo.com and right-click on Users and select New > Group In the New Object Group Windows, enter AMT RADIUS Clients in the Group name field Click OK 15
20 Set Permissions on RADIUS Security Group Right Click on AMT RADIUS Clients Group and select Properties In the AMT RADIUS Clients Properties Window, click the Security Tab and Click the Add button In the Select Users, Computers, or Groups Window, add ConfigMgr Primary Site Servers Click OK We have now created an AD OU, AMT Radius Group, and given the Security Group that ConfigMgr 2007 SP2 Server is a member of, the proper permission to create Management Controllers objects for each Intel vpro system during the 16
21 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 provisioning phase. We have now created an AD OU and given the ConfigMgr 2007 Server proper permissions to create Intel AMT objects for each Intel vpro technology based system during the provisioning phase. 17
22 Section 4.0: Configure Enterprise PKI Certificate Server For more information, refer to the following Microsoft* TechNet article: Certificate Requirements for Out of Band Management (Uhttp://technet.microsoft.com/en-us/library/cc161874(TechNet.10).aspxU ). ConfigMgr 2007 SP2 uses four types of certificates for Out Of Band Management. These four different certificates are: AMT Self Signed certificate Intel AMT will generate a self-signed certificate during the PKI provisioning process to secure the connection with the ConfigMgr 2007 Server. AMT provisioning certificate This certificate is used by ConfigMgr 2007 to provision Intel AMT devices. This certificate can either be purchased from a third- party Certificate Authority or generated by an in-house Enterprise Certificate Authority. The most simple and automated method for provisioning is the process of purchasing this certificate from a third- party provider (VeriSign, GoDaddy, Comodo, or Starfield). This certificate will need to be installed on each OOB Service Point in the environment. Web server certificate - This certificate is generated by an internal Enterprise Certificate Authority during the provisioning process and installed on each AMT device within the firmware. This will allow for a TLS management session between the ConfigMgr 2007 OOB Management console and the AMT firmware. WS-Man Translator certificate The WS-Man translator also users a Web Server certificate to secure the communications to and from the ConfigMgr 2007 server during Legacy Provisioning. This will be covered in more detail during the WS-Man Translator section x RADIUS Certificate Optional certificate that allows the Intel AMT client to securely authenticate to an 802.1x network without the operating system being present. The process for generating the Certificate Signing Request (CSR) and requesting the provisioning certificate from a third-party certificate authority can be found in the following resources: Microsoft* TechNet, Requesting and Installing the AMT Provisioning Certificate from an External CA (Uhttp://technet.microsoft.com/en-us/library/dd aspx#BKMK_AMTprovisioning12008U ) Intel vpro Expert Center, Request and Install a Provisioning Certificate from VeriSign (Uhttp://communities.intel.com/docs/DOC-2200U ) Intel vpro Expert Center, Obtaining a Provisioning Certificate for Intel vpro Platforms using OpenSSL Tools (Uhttp://communities.intel.com/docs/DOC-2110U) Intel vpro Expert Center, How to procure and install a Verisign Cert for Remote Configuration on SCS (Uhttp://communities.intel.com/community/openportit/vproexpert/blog/2008/03/19/how-to-procure-and-install-a-verisign-certfor-remote-configuration-on-scsU) 18
23 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Open your Certificate Authority issuing PKI Server - Click Start > All Programs > Administrator Tools > Certification Authority Expand DC1.vprodemo.com Right Click on Certificate Templates > Manage In the Certificate Templates Console Window, right click on Web Server and select Duplicate Template In the Duplicate Template Window, select the radio button for Windows 2003 Server, Enterprise Edition Click OK 19
24 In the Properties of New Template Window: Enter ConfigMgr AMT Web Server Certificate Check the Box to Publish certificate in Active Directory Proceed to next step to set the security rights on this template. Select the Security Tab and click Add Select the ConfigMgr 20
25 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP primary site server computer group Click OK With the ConfigMgr Primary Site Servers group highlighted, check Read and Enroll Click OK Close the Certificate Templates Console 21
26 In the Certificatio n Authority Window, right-click on Certificate Templates > New > Certificate Template to Issue In the Enable Certificate Templates Window, select ConfigMgr AMT Web Server Certificate (this template was created in the previous step) Click OK 22
27 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the Certification Authority Window, you will now see ConfigMgr AMT Web Server Certificate listed in the right hand Window and ready for use by the Out of Band Service Point Note: This Web Server Template will be used by ConfigMgr 2007 SP2 to generate a unique certificate for each Intel AMT system during the provisioning process, and used for TLS session during management of the Intel AMT client. Configure Root CA to Allow Revocation of Client Management Controller Certificates In the Certification Authority Window, rightclick on DC1.vprodemo.com and select Properties 23
28 In the Properties Window, select the Security tab Click Add Configure Root CA to Allow Revocation of Client Management Controller Certificates Add the ConfigMgr Primary Site Servers group Click OK. 24
29 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Select the ConfigMgr Primary Site Servers group. Check Allow for Issue and Manage Certificates permissions for this group (leave Request Certificates option unchanged). Click OK. Note: This setting is required when you are performing actions like an unprovision of the Management Controller. This will keep your PKI issued certificates cleaned-up (revoked). Your PKI server is now configured with a Web Certificate Template that ConfigMgr 2007 will use during the provisioning phase to generate a TLS certificate for each Intel AMT device. 25
30 Section 5.0: Install ConfigMgr 2007 SP2 These are the steps used to install a basic installation of ConfigMgr 2007 SP2 for a lab environment to test the Out Of Band Management capabilities for Intel vpro technology based systems. Lab setups and names will vary for your environment. Contact Microsoft for the latest version of ConfigMgr 2007 SP2. Please refer to Microsoft for the complete setup documentation: Uhttp://technet.microsoft.com/en-us/library/bb735860(TechNet.10).aspxU Launch SPLASH.hta Click Install Configuration Manager 2007 SP2 26
31 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Click Next on the Welcome screen Select to Install a Configuration Manager Site Server Click Next Check I accept these license terms Click Next Select Custom Settings for installation Click Next Select Primary Site Click Next Select If you want to participate to help Microsoft Click Next 27
32 Enter Product Key Click Next Enter destination folder Click Next Enter in the three letter site code (PRO used in this example) Click Next Select Configuration Manager Mixed Mode Note: Native mode is required if you are managing Internet clients. Click Next Select all of the Client Agent options except Network Access Protection Click Next Enter the name of the SQL 2008 database (SCCM in this example) to setup the ConfigMgr 2007 database (Default name SMS_PRO) Click Next 28
33 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Enter the name for the ConfigMgr 2007 server (SCCM used in this example) Click Next Enter in the FQDN of the ConfigMgr 2007 Server (SCCM. VPRODEMO.COM used in this example) to install the Management Point Click Next Use default port Click Next Select Check for updates and download newer version to alt path Click Next After the prerequisite files have been successfully downloaded (Internet connection required), click OK Review the Settings Summary and click Next Installation started 29
34 The first part of the installation does a Prerequisite check. In this example, Setup discovered that WSUS on the Primary Site Server was missing (it is listed only as a warning but, you can add it anyway.) This component is only necessary if you are going to do Software Updates internally from a WSUS location. If you get this error message: Web-based Distributed Authoring and Versioning (WebDAV) is required for the management point and distribution point site system roles. If you have selected to install a site role requiring WebDAV, and it is not enabled, this rule will fail. Webbased Distributed Authoring and Versioning (WebDAV) is not enabled and/or IIS 6 WMI compatibility component for IIS is not installed on the computer specified for management point installation or setup was unable to verify remote IIS settings because IIS common components were not installed on the site server computer. ConfigMgr requires WebDAV to be installed and enabled in Internet Information Services (IIS) for management point site systems. Setup cannot continue. Add the WebDAV component in the WWW Services within Windows 2008 Server (requires Windows 2008 installation CD). 30
35 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 (Installation will continue after WSUS and WebDAV were added.) Installation Completed Successfully! 31
36 Section 6.0: Install Out of Band Management Service Point Uhttp://technet.microsoft.com/en-us/library/cc161863(TechNet.10).aspxU The Out Of Band Service Point is the ConfigMgr 2007 component responsible for provisioning and managing Intel vpro technology based systems. The following section will provide the necessary steps for installing this OOB Service Point and Configuring for Intel vpro technology based systems. These steps assume that you have installed ConfigMgr 2007 SP2 on a supported server. For steps to install ConfigMgr 2007 SP2, please refer to the previous section, or to the Microsoft TechNet documentation. OOB Management (as defined by Microsoft in ConfigMgr 2007 Help File): Out of band management allows an administrator to connect to a computer's Umanagement controlleru when the computer is turned off, in sleep or hibernate modes, or otherwise unresponsive through the operating system. OOB Service Point ConfigMgr 2007 Service component responsible for provisioning and managing Intel AMT enabled devices. On the ConfigMgr 2007 SP2 Server, open the Configuration Manager console Navigate to System Center Configuration Manager > Site Database > Site Management > Pro vpro Demo SCCM > Site Settings > Site Systems Right-click ConfigMgr 2007 Server (\\SCCM in this example) Select New Roles to launch the New Site Roles Wizard 32
37 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 On the General page, click Next (default settings) On the System Role Selection page, check Out of band service point Click Next 33
38 On the Out of Band Service Point page, click Next Note: change any default settings you require for how out of band transmission packets are sent Click Next again on Summary page Once the Wizard completes, click Close 34
39 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 You will now see ConfigMgr out of band service point listed under the ConfigMgr 2007 Site System (SCCM in this example) You have now added the Out Of Band Service Point to your ConfigMgr 2007 server. This service will provide the capability to provision and manage Intel AMT devices. The next section will cover the configuration process of this OOB Service Point. 35
40 Section 6.1: Configure Out of Band Management Service Point on ConfigMgr 2007 Uhttp://technet.microsoft.com/en-us/library/cc161822(TechNet.10).aspxU In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Site Management > Pro vpro Demo SCCM > Site Settings > Component Configuration Right-click Out of band management component, and then click Properties On the General tab, Under the Provisioning Settings, click Browse to select the Active Directory container to store each AMT object Click Yes at the security warning 36
41 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Select Out of Band Management Controllers from the Domain (vprodemo in this example) This is the OU create in Section 3.0 Click OK Click Set and provide the MEBx admin password (e.g. to be set during provisioning. The password must be a strong password (8 or more characters, a special character, and a mixture of upper and lower case characters). Note: This MEBx password setting is used for ConfigMgr 2007 to change the local password on the Management Controller during the provisioning process. By default, the factory setting for the password is admin. If this password was manually changed locally on the MEBx, this will be ignored. This password will modify the local and remote MEBx password of AMT during the provisioning process. Click OK on the MEBx Account dialog Leave AMT Provisioning Port as default: 9971 Note: AMT Provisioning port can be modified if necessary, but requires modification on each Intel AMT system. 37
42 Check the box to Register ProvisionServer as an alias in DNS Note: This creates an Alias in your DNS environment to allow provisioning hello packets from AMT to get routed to the ConfigMgr 2007 server. This is not required for Agent Initiated Provisioning using the ConfigMgr 2007 Client Agent. Also, the necessary rights to your DNS environment would need to be granted to allow for the ConfigMgr 2007 server to update an Alias record in your DNS environment. Under the Certificates section, Click Browse and select a valid Remote Configuration Provisioning Certificate (Intel(R) Client Setup Cert Verisign vprodemo Backup.pfx is used in this example). This certificate is the Provisioning Certificate that was either purchased from a 3 rd Party Certificate Authority (e.g. VeriSign) or created from an Internal CA. For complete steps to create an external Provisioning Certificate for a 3 rd party Certificate Authority: Uhttp://technet.microsoft.com/enus/library/cc161804(TechNet.10).aspx#BKMK_AMTprovisioning1U For complete steps to generate your own certificate from an internal PKI, see: Step-by-Step Example Deployment of the PKI Certificates Required for AMT and Out of Band Management: Windows Server 2008 Certification Authority, Uhttp://technet.microsoft.com/enus/library/dd aspxU. You can also refer to Intel vpro Expert Center for steps to purchase a certificate: Uhttp://communities.intel.com/openport/blogs/proexpert/2008/03/19/ho w-to-procure-and-install-a-verisign-cert-for-remote-configuration-onscsu 38
43 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Click Open Enter the password for this certificate and click OK Note: If the password is incorrect, you will receive and Invalid Password message. If the certificate is not a valid Remote Configuration Certificate, you will receive an Invalid Certificate message. Click Select for the AMT Certificate Template Select ConfigMgr AMT Web Server Certificate Click OK Click Apply Note: The ConfigMgr AMT Web Server Certificate Template was previously generated within this image and the steps to create are not covered in this section. ConfigMgr 2007 Help file has complete steps on how to create and apply the appropriate settings to this template. These steps will vary based on the environment 39
44 Please refer to Microsoft TechNet and closely review the necessary PKI Certificates required for Out Of Band Service Point - Uhttp://technet.microsoft.com/en-us/library/cc161874(TechNet.10).aspxU On the AMT Settings tab, click Accounts icon to add AMT User Note: These are Windows Domain accounts/groups that ConfigMgr 2007 applies to AMT during the provisioning phase. These accounts will authenticated via Kerberos during the OOB management sessions. In the AMT User Account Setting window, click Browse and add the VPRODEMO\Administrator account, click OK Note: Please review Microsoft TechNet documentation to understand the appropriate users and rights for your environment. This example simply uses the domain administrator for lab testing purposes only. Choose Platform Administration. Check all of the boxes for the related Supported AMT Features for this account, click OK 40
45 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Click Apply In the Default IDE-redirect image text box, enter a previouslydefined share location that will host your.iso images to be used with redirection capabilities. (\\SCCMSP2\IDER\dos_gold.iso is used in this example). Check the following boxes: Enable Web interface for AMT systems Enable serial over LAN and IDE-redirect for AMT systems Allow ping responses Enable BIOS password bypass for power on and restart commands Enable Support for Intel WS-MAN Translator (this allows OOB Service Point to communicate with AMT systems that have firmware less than 3.2.1) Default setting for Kerberos clock tolerance (5) Click Apply 41
46 On the Provisioning Settings Tab, click User and Password to add a Digest Note: This is a digest account and password that is used to authenticate to the management controller during provisioning (this is not a domain account). You should add admin password to match the local MEBx password modified when going into the MEBx (CTRL+P). If you have not modified the MEBx on the system, ConfigMgr 2007 is programmed to try the default OEM password of admin. Enter: Name: TestUser used in this example Password: P@ssw0rd (using a zero in this example) Click OK Click OK again. Note: This digest account can be used when you have a mixed environment when the MEBx has been modified to different passwords (e.g. different ISV consoles) and ConfigMgr can use these user/password information to connect to these Intel vpro systems.. You have completed the installation and configuration of the Out Of Band Service Point in ConfigMgr 2007 SP2. 42
47 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Section 6.2: Configure Network Discovery for Management Controllers In this section, we will configure ConfigMgr 2007 to be able to discover AMT Management Controllers in a lab setting. In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Site Management > VPD vpro Demo Site > Site Settings > Discovery Methods In the right hand window, Right-click Network Discovery, and then click Properties On the General tab, select Enable discovery of management controllers Click OK 43
48 Section 6.3: Configure New Site Boundary In this section, we will configure ConfigMgr 2007 Site Boundary for a lab setting. Net Boundary is only one type of boundary and other options are available. A requirement is at least one Site Boundary setup and configured. Some configurations settings in these steps will vary based on your lab setup. Note: the new site boundary is not required for OOB management of Intel vpro clients, but is required for agent installation on the clients. In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Site Management > VPD vpro Demo Site > Site Settings Right click on Boundaries and select New Boundary 44
49 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Enter the following fields Description = Net Boundary Site Code = Site Code (VPD-vPro Demo Site used in this example and may vary in your lab) Type = IP Address Range Starting Address = (Use the IP Address range appropriate for your lab environment) Ending Address = (Use a small range to limit the discovery amount low) Network Connection = Fast Click OK 45
50 Section 7.0: ConfigMgr 2007 Collection Setup In this section, you will configure your ConfigMgr 2007 Server with an Intel AMT Collection, setup your Intel vpro technology based system with a ConfigMgr 2007 Agent, and enable the agent to initiate the in-band Provisioning Process with your ConfigMgr 2007 Server. Section 7.1: Create Intel AMT Unprovisioned Collection In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Computer Management > Collections Right click on Collections and select New Collection In the New Collection Wizard, enter the name Unprovisioned vpro Clients and add optional Comments as required Click Next 46
51 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the Membership Rules window, click the Query Rule Properties (it is the Database icon) In the Query Rule Properties window, enter the name Unprovisioned vpro Clients Click Edit Query Statement... In the Unprovisioned vpro Clients Query Statement Properties window, click Show Query Language 47
52 In the Query Statement textbox, type: SMS_R_SYSTEM.ResourceID,SMS_R_SYSTEM.ResourceType,SMS_R_S YSTEM.Name,SMS_R_SYSTEM.SMSUniqueIdentifier,SMS_R_SYSTEM. ResourceDomainORWorkgroup,SMS_R_SYSTEM.Client from SMS_R_System inner join SMS_G_System_AMT_AGENT on SMS_G_System_AMT_AGENT.ResourceID = SMS_R_System.ResourceId where SMS_G_System_AMT_AGENT.AMT >= "0" and (SMS_R_System.AMTStatus!= "3" or SMS_R_System.AMTStatus is NULL) Note: This will pull all the clients that are enabled for Intel vpro technology, and in an unprovisioned state. Note: Additionally, you can setup a collection for Provisioned Clients by using the following Query Statement: Select * from SMS_R_System where AMTStatus=3 This will show ALL vpro systems that have been provisioned. For more information on Intel AMT status codes, see the link below: Uhttp://technet.microsoft.com/en-us/library/cc aspxU Click OK and OK again on the Query Rule Properties Note: Refer to Microsoft TechNet for complete details on this step: Uhttp://technet.microsoft.com/en-us/library/cc161856(TechNet.10).aspxU In the Membership Rules window, click Next 48
53 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the Advertisement window, add any desired advertisements and click Next In the Security window, add any appropriate users or groups and click Next (keep default) 49
54 In the Confirmation window, click Close 50
55 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Section 7.2: Configure Intel AMT Collection to Automatically Provision Intel AMT Devices In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Computer Management > Collections > Unprovisioned vpro Clients Right click on Unprovisioned vpro Clients and select Modify Collection Settings In the Unprovisioned vpro Clients Settings windows, click the Out of Band tab Check the checkbox Enable Automatic out of band management controller provisioning and click OK Note: This setting is what enables ConfigMgr 2007 Clients to automatically provision with ConfigMgr Note: see Microsoft TechNet article for complete details: Uhttp://technet.microsoft.com/enus/library/cc161955(TechNet.10).aspxU 51
56 Add Intel AMT Columns to ConfigMgr 2007 In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Computer Management > Collections > Unprovisioned vpro Clients Click the Unprovisioned vpro Clients collection, right click in the right hand window, and select View > Add Remove Columns In the Add/Remove Columns window, add AMT Status, AMT Version, and Automatic AMT Provisioning to the Displayed columns Click OK In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Site Management > VPD vpro Demo Site > Site Settings > Discovery Methods Double Click on Active Directory System Discovery Note: With the collection defined, you can use any of the discover methods that ConfigMgr 2007 provides (AD System Group, AD Security Group, AD System, AD User, Heartbeat, or Network) to discover the client. Refer to Microsoft documentation for understanding the appropriate method for your environment. This method is used simply for lab testing purposes only. 52
57 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the Active Directory System Discovery Properties window General tab, check Enable Active Directory System Discovery Click the button In the New Active Directory Container window, select Local Domain and click OK In the Select New Container window, select Computers Click OK 53
58 On the Polling Schedule tab, check the box to Run discovery as soon as possible Click Apply Note: This will initiate a discovery of all the systems listed in the computer OU in the Active Directory. After you run the discover method Right Click Collection and select Update Collection Membership Click Yes to confirm that you want to proceed Right click on All Systems and select Refresh The client will now appear in the All Systems Collection Note: If may take a couple minutes for the system to show up. You may continue to click Update Collection until you still the client in the collection. The AMT status of the device will most likely be in a unknown state. In this example, you will see ConfigMgr 2007 has discovered HP7800 system that was joined to the domain. The AMT Status = Unknown at this time 54
59 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 After the client is populated in the All Systems Collection, check to see if any of the systems are enabled for Intel vpro technology. Right Click on All Systems > Out of Band Management > Discover Management Controllers Note: This will scan through your collection and validate which clients are enabled for Intel vpro technology and ready to be provisioned. Click OK After a few minutes, depending on the size of your collection, you can update your collection membership Right Click Collection and select Update Collection Membership Click Yes to confirm that you want to proceed Right click on Unprovisioned vpro Clients collection and select Refresh The client will now appear in Unprovisioned vpro Clients Collection and listed as Not Provisioned Note: If you look back at the All Systems collection, you will now see the system as listed as Not Provisioned. You will also see the version of AMT listed. 55
60 Section 8.0: ConfigMgr 2007 Agent Installation and In-Band Provisioning There are several methods to perform a ConfigMgr 2007 Agent installation on an Intel vpro technology based system. The steps listed in this section are used simply for a lab environment. Refer to Microsoft documentation to understand the various methods to distribute Microsoft ConfigMgr 2007 Agent: Uhttp://technet.microsoft.com/en-us/library/bb633063(TechNet.10).aspxU On the ConfigMgr 2007 Server, copy the entire directory C:\Program Files\Microsoft Configuration Manager\Client to a USB drive (or other device to copy to your Intel vpro technology based systems). Copy this Client directory to each of your Intel vpro technology based systems. 56
61 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 On the client system, open a command prompt and navigate to the Client folder you copied over to the client system. From the command prompt, run the following command: ccmsetup /mp:sccmservername /logon smssitecode=3 Letter ConfigMgr 2007 Site Code Note: Make sure to use your ConfigMgr 2007 Server Name and the 3 letter Site code for your lab environment. (example ccmsetup /mp:sccmsp2 /logon smssitecode=vpd) Run ccmsetup /? for a complete list of command switches. Track the setup process by monitoring the Process ccmsetup.exe in Task Manager 57
62 Installation is complete once the CcmExec.exe process is running in Task Manager You can track the agent installation on the client in c:\windows\system32\ccmsetup\ccmsetup.log Note: If you update the All Systems Collection in ConfigMgr 2007, you will see Yes in the Client Column after the Agent installation is complete. On the client system, open the Control Panel After the Agent installation is complete, you will see a Configuration Manager Icon 58
63 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Double Click the Configuration Manager Icon Select the Actions Tab Click on Machine Policy Retrieval & Evaluation Cycle and click Initiate Action button Click OK in the window indicating the action has been initiated Repeat Previous Step: Click on User Policy Retrieval & Evaluation Cycle and click Initiate Action button Click OK in the window indicating the action has been initiated Note: This process will speed up the provisioning cycle rather than waiting for the schedule event to occur. 59
64 After the Agent has pulled down the machine policies from the ConfigMgr 2007 server, you will see more Actions listed in the Actions tab of the Configuration Manager Note: You can track the progress by monitoring the logs directory c:\windows\system32\ccm\logs OOBMGMT.log will track the progress of the auto provisioning of AMT. PolicyAgent.log will track all of the policies pulled down by the agent from ConfigMgr 2007 server. After a few minutes, provisioning will complete and you can update your collection membership on your ConfigMgr 2007 Server Right click Collection and select Update Collection Membership Click Yes to confirm that you want to proceed Right click on All Systems collection and select Refresh The client will now appear in All Systems Collection Provisioned and no longer be listed in the Unprovisioned 60
65 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 vpro Clients collection Note: You can track the provisioning progress under C:\Program Files\Microsoft Configuration Manger\Logs\Amtopmgr.log 61
66 Section 9.0: Legacy Provisioning If you are provisioning Intel vpro clients that have a version of Intel AMT less than 3.2.1, you will need to install the Intel WS- MAN translator on the ConfigMgr 2007 server system. For more information on the WS-MAN translator, follow the links below: Uhttp://softwarecommunity.intel.com/articles/eng/3840.htmU Link to download translator: Uhttp://software.intel.com/en-us/articles/intel-ws-management-translatorU Also, here is a link to information about how to setup and use the translator: Uhttp://communities.intel.com/openport/blogs/microsoft-vpro/2008/08/19/intel-wsman-translator-10-released In addition, you will need to import client identification and authentication information using the ConfigMgr s Import Wizard. Once you have imported the client authentication information, you will need to manually configure Intel AMT on each Intel vpro client, using the Intel Management Engine BIOS Extension (Intel MEBx). NOTE: If you are provisioning clients with Intel AMT or greater and are choosing not to install the ConfigMgr 2007 agent on the clients (referred to as In-Band provisioning), then you do not need to install the WS-MAN translator. In this case, follow the procedures in section 9.2 to import the client authentication information into ConfigMgr 2007, after which the clients will be automatically provisioned (provided you have installed and configured a certificate server with a matching provisioning cert) once they have been restarted and allowed to boot to the Windows OS. 62
67 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Section 9.1: Intel WS-MAN Translator Installation and Configuration Web Services Management (WS-MAN) describes the interaction and execution order among the various PC components to execute a management command. ConfigMgr 2007 communicates with Intel AMT using WS-MAN only. However, versions of Intel AMT older than version do not understand WS-MAN. They understand only the EOI protocol (Intel AMT and above works with both WS-MAN and EOI). So, Intel developed the WS-MAN translator to translate WS-MAN to EOI and vice-versa. Generate a Certificate Request on SCCM Server for Intel WS-MAN Translator On the SCCM Server, go to Start > All Programs > Administrative Tools > Internet Information Services (IIS). Expand Web Sites and right-click on Default Web Site and select Properties. In the Default Web Site Properties window, select the Directory Security tab. In the Secure Communications section, click the Server Certificate button. 63
68 This will launch the Web Server Certificate Wizard. Click Next. In the IIS Certificate Wizard window, select Create a new certificate. Click Next. Select Send the request immediately to an online certification authority. Click Next. 64
69 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Enter a Name for the certificate: WS- MAN Translator Server Certificate. Click Next. Enter Organization Information Organization: Intel Organization Unit: Training Click Next. Enter the Common name: sccmsp2.vprodemo.com Note: The Common Name must match the FQDN of the SCCM Server. Click Next. 65
70 Enter in your Geographical Information Country: US State: Oregon City: Hillsboro Click Next. Enter 443 for the SSL Port for this web site. Click Next. In the Choose a Certification Authority window, select vprodemdc.vprodemo.com\vprodemoc A Note: This will send you web server certificate request to this CA. Click Next. 66
71 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Confirm your request and click Next. Once Wizard is complete, click Finished. Install Intel WS-Man Translator on the SCCM Server On the SCCM Server, go to C:\Install and double click the WsTransSetup 532.msi setup file. In the Intel WS-Management Translator setup window, click Next. 67
72 Click Next. During the installation, keep all of the default settings until installation wizard is complete and installation has finished. Once the installation is complete, you will see a new program has been added to your All Programs Group: Intel WS- Management Translator. 68
73 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Configure Intel WS-Man Translator Click Start > All Programs > Intel WS-Management Translator > wtranscfg.exe to configure the Translator. In the WS-Translator Configuration Wizard window, select Set common setup accounts Set TLS/forwarding options Set WinRM Options (optional) Note: You can set common runtime accounts that the translator will use to connect to legacy management controllers. Instead for this lab, we will configure Delegation for the SCCM server in the next section. Click Next. 69
74 In the Set initial setup password window, enter for the setup password (admin is default user). Click Next. In the Set Common Pre-Shared Key window, leave the default Key Name and Key Values. Note: Remember these values so you can manually enter this information into the Intel MEBx in the next lab module. Also, for real world implementations, you should select a more random and secure PID and PPS for security reasons. Click Next. 70
75 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the Import Common Setup Certificate window, click Browse. Browse to c:\certificates and open the Intel Client Setup Cert Verisign vprodemo Backup.pfx file. Password on the Certificate: Pr0t3ct!0n Click Next. Note: This is the Verisign Certificate (previously purchased for this training) used for Remote Provisioning. Uncheck Allow Basic Authentication, if desired. In the Select TLS/forwarding options windows, select (default options) Listening Port: 443 Forwarding Port: For the Server Certificate: select the WS-Man Translator certificate created in previous step: CN=sccmSP2.vprodemo.com Thumbprint=CD7A1097E822DD9B3E0 FBBFF3D AE305D (thumbprint varies per certificate you created view thumbprint on the 71
76 certificate created in previous step) Click Finished. Click OK to restart the Translator Service. Validate Intel WS-Man Translator is configured properly On the ConfigMgr 2007 Server, open Internet Explorer and go to Uhttps://sccmSP2.vprodemo.com/wstransU You will see the following web page if the WS-Man Translator is configured properly, including the Web Server Certificate. Congratulations! You have just installed and configured the Intel WS- Management Translator for SCCM to be used with legacy Intel AMT systems (firmware < 3.2.1). 72
77 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Modifying Windows Remote Management (WinRM) On the SCCM Server, open a command prompt and run the following command: winrm set (command line is case sensitive). Note the spaces and syntax in the image. You should see Basic = True returned. Note: When SCCM does provisioning and collection based power control, it connects to the Intel AMT client with digest credentials. To get the Translator to accept digest credentials, you need to enable Basic Authentication in WinRM. Set Delegation for the SCCM Server When WS-MAN Translator passes credentials from the OOBC to the Intel vpro client, it is doing it as Delegated. For the Active Directory to allow this, you need to check Trust computer to delegation on the SCCM server AD object. This will keep the token valid when it is passed. Just browse to the computers in the AD, open up the proprieties for the ConfigMgr 2007 server and check the box located on the General tab. On your Domain Infrastructure Image, click Start > All Programs > 73
78 Administrator Tools > Active Directory Users and Computers > vprodemo.com > Computers. Right-click on SCCMSP2 Server and select Properties. Check the box Trust Computer for Delegation. Click OK. Note: Reboot the ConfigMgr 2007 Server image after previous installation and changes were made. Note: If you do not do this, you will need to setup the WS-MAN Translator (during configuration steps above) run time account with a user that has permission to the Intel AMT client. At that point the credentials configured in the run time account are used to manage the client. Section 9.2: ConfigMgr Import Wizard for PSK Provisioning with Intel WS-MAN Translator The Import Computer for Out of Band Management Wizard in Configuration Manager 2007 SP2 imports new computer information into the Configuration Manager database. This allows administrators to provision computers for Intel AMT when: Computers do not have the Configuration Manager 2007 SP2 client installed, including computers that currently have no operating system installed (aka Bare Metal Provisioning) Legacy Intel AMT systems (<3.2.1) that are not natively supported by ConfigMgr 2007 and use the Intel WS-Man Translator for Provisioning 74
79 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Intel AMT systems that are being migrated from another Provisioning environment to a ConfigMgr 2007 environment (e.g. SMS -> ConfigMgr) (Uhttp://technet.microsoft.com/en-us/library/cc161950(TechNet.10).aspxU) Collect System Information on the client system to import into SCCM On the client system, right click on Computer and select Properties. Record the Host Name and the Full Computer Name (FQDN). On the desktop of the client system, create a script GetProvisionData in the folder c:\uuid Info using the code example in the appendix of this document. Create the new folder if necessary. Once the script is created, open c:\uuid Info Folder. Double-click the GetProvisionData script. 75
80 This utility will pull the Host Name, FQDN, MAC Address, and UUID of the system and display in a window. Record this information for later use in the ConfigMgr Import Wizard. Click OK. Import Intel vpro System Information into ConfigMgr OOB Import Wizard In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Computer Management. Right-click on Collections, and select Import Out of Band Computers. Note: This will launch the OOB Import Wizard. 76
81 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the OOB Import Wizard, select Import single computer Note: You can use a the file option to import multiple system at once (e.g. Migration purposes) Click Next. In the Single Computer import window, use the information you recorded previously from your client system to enter: Computer Name FQDN MAC Address (Enter 11:11:11:11:11:11 for MAC) SMBIOS GUID (this is the UUID you recorded) MEBx Password = P@ssw0rd Confirm Password = P@ssw0rd Remote Admin Password = P@ssw0rd Confirm Password = P@ssw0rd Note: The Intel MEBx and Remote Admin passwords are only needed if the Intel AMT passwords are different than what was set 77
82 in the OOB Component Settings. Click Next. Confirm the Data Preview and click Next. 78
83 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 In the Choose Target Collection screen, select Add new computers only to the All Systems collection. Click Next. Confirm the summary information displayed and click Next. 79
84 The Wizard will complete and confirm the import was successful. Click Close. In the Configuration Manager console, navigate to System Center Configuration Manager > Site Database > Computer Management > Collections Right-click All Systems and select Update Collection Membership. Refresh the Collection. Note: You will now see the system you imported into the All Systems Collection; AMT Status Unknown. ConfigMgr 2007 is now waiting for Hello Packets with a PSK from the Intel vpro client system. 80
85 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Manually enter the PID / PPS into Intel MEBx Reboot the client and press CTRL + P to enter the Intel MEBx Interface. Enter the password: P@ssw0rd. Select Intel (R) AMT Configuration and press Enter. Select Un-Provision and Enter. Click Y for Yes to Reset Intel AMT. Select Full Unprovision and Enter. Select Setup and Configuration and Enter. Select TLS PSK and Enter. Select PID and PPS and Enter. Enter PID = Enter PPS = Exit from the Intel MEBx and let system reboot. Note: You will recall that these same PID/PPS keys were used during the setup of the Intel WS-Man Translator. Upon reboot, the system will send hello packets to the SCCM server with PID/PPS. 81
86 Intel AMT Provisioning Log On the ConfigMgr 2007 Server Image, open the AMT Provisioning Log (C:\Program Files\Microsoft Configuration Manager\ Logs\amtopmgr.log). In this log, you will see the Hello packets from your HP7800 system with the matching PID ( ). This Hello packet will start the provisioning process. Note: If the PID /PPS keys were not imported or do not match, the provisioning process will fail and the log will indicate that the system has not been imported into ConfigMgr
87 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Section 10.0: Helpful ConfigMgr 2007 Logs for Troubleshooting Section 10.1: Server Logs C:\Program Files\Microsoft Configuration Manger\Logs AMTOPMGR.LOG - log for tracking provisioning process AMTPROXYMGR.LOG log to help identify failures with CA and OU C:\Program Files\Microsoft Configuration Manger\AdminUI\AdminUILog OOBConsole.log - Log for tracking OOB Management Console activity (note: for more detailed information - change "Error" to "Verbose" in the following file c:\program Files\Microsoft Configuration Manager\AdminUI\bin\oobconsole.exe.config Section 10.2: Client Logs C:\windows\system32\ccm\logs oobmgmt.log log to track the provisioning of AMT C:\windows\system32\ccmsetup ccmsetup.log log to track installation progress of ConfigMgr 2007 Client Agent 83
88 Section 11.0: Resources Intel vpro Expert Center devoted to Microsoft products and Intel vpro technology - Uhttp://communities.intel.com/openport/blogs/microsoft-vproU Microsoft TechNet Reference Material System Center Configuration Manager Uhttp://technet.microsoft.com/en-us/library/bb735860(TechNet.10).aspxU Out of Band Management in ConfigMgr 2007 SP2 - Uhttp://technet.microsoft.com/en-us/library/cc161989(TechNet.10).aspxU Intel Software To support systems earlier than 3.2.1, an Intel WS-Man Translator is required with ConfigMgr Intel WS-MAN Translator version Uhttp://softwarecommunity.intel.com/articles/eng/3840.htmU 84
89 Configuration Guide for Intel vpro Technology with Microsoft* ConfigMgr SP2 Appendix: Code Example for GetProvisioningData Script 'SCCM Import Data Generation Script 'Created by Dan Brunton, Intel Corporation 'This script will connect to the local system via WMI and output the hostname, FQDN, MAC address and UUID to a file. Option Explicit 'Change this to pont to whatever directory you want the script to write to. It could be a local path or a network share. strdirectory = "c:\temp" 'Change this to the file name you want to have the data written to. strfile = "\import.csv" 'Define the variables used in the script. dim objnicinfo, objnic, objsyscomps, objitem, objservice, objsysmac, objnetwork, objfso, objfolder, objshell, objtextfile, objfile dim struuid, strhostname, strdnsdomain, strmac, strdirectory, strfile, strtext 'Define the WMI interface object to retrieve information with. Set objservice = GetObject("winmgmts:\root\cimv2") 'Use the Win32_NetworkAdapter class to retrieve the MAC address and computer name for supported network adapters. Depending on the platform you are using, the NIC you may need to add or change NIC descriptions in the query below. Set objnicinfo = objservice.execquery("select * FROM Win32_NetworkAdapter where description='intel(r) 82566DM Gigabit Network Connection' or Description = 'Intel(R) 82566MM Gigabit Network Connection'") For Each objnic in objnicinfo strmac = objnic.macaddress strhostname = LCase(objNIC.SystemName) 'The hostname comes in as upper case, LCase changes it to lower case. There is no functional need to do this, it is purely ascetic. Next 'Use the Win32_NetworkAdapterConfiguration class to get the DNS suffix for the NIC identified above. Set objnetwork = objservice.execquery ("Select * from Win32_NetworkAdapterConfiguration WHERE MACAddress = '" & strmac & "' and DNSHostName = '" & strhostname & "'") for each objitem in objnetwork strdnsdomain = objitem.dnsdomain next 'get UUID Set objsyscomps = objservice.execquery("select * from Win32_ComputerSystemProduct") For Each objitem in objsyscomps struuid = objitem.uuid next 'Assemble the various data elements into a single string. strtext = strhostname & "," & strhostname & "." & strdnsdomain & "," & strmac & "," & struuid 85
90 'This section writes information retrieved from the script to a file. Set objfso = CreateObject("Scripting.FileSystemObject") 'Check to see if the strfile exists and create it if it does not If objfso.fileexists(strdirectory & strfile) Then Set objfolder = objfso.getfolder(strdirectory) Else Set objfile = objfso.createtextfile(strdirectory & strfile) End If set objfile = nothing set objfolder = nothing Const ForAppending = 8 'Create the file object Set objtextfile = objfso.opentextfile(strdirectory & strfile, ForAppending, True) 'Append the value of strtext to the text file and close it objtextfile.writeline(strtext) objtextfile.close 86
91 Intel vpro Processor Technology Out of Band Management Quick Start Guide *Other names and brands may be claimed as the property of others. Copyright 2008, 2009, 2010 Intel Corporation. All rights reserved. Intel, the Intel logo, Intel. Leap ahead, the Intel Leap ahead Logo, Centrino, the Centrino logo, Intel Core, vpro, the vpro logo, Intel SpeedStep, Pentium, Core and Celeron are registered trademarks of Intel Corporation in the United States and other countries.. Intel Active Management Technology requires the computer system to have an Intel AMT-enabled chipset, network hardware and software, as well as connection with a power source and a corporate network connection. Setup requires configuration by the purchaser and may require scripting with the management console or further integration into existing security frameworks to enable certain functionality. It may also require modifications of implementation of new business processes. With regard to notebooks, Intel AMT may not be available or certain capabilities may be limited over a host OSbased VPN or when connecting wirelessly, on battery power,
92 sleeping, hibernating or powered off. For more information, see Uhttp:// INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel may make changes to specifications and product descriptions at any time, without notice. Intel Active Management Technology requires the platform to have an Intel AMT-enabled chipset, network hardware and software, connection with a power source, and a network connection. 88
Deploying System Center 2012 R2 Configuration Manager
Deploying System Center 2012 R2 Configuration Manager This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS, IMPLIED, OR STATUTORY, AS TO THE INFORMATION IN THIS DOCUMENT.
NSi Mobile Installation Guide. Version 6.2
NSi Mobile Installation Guide Version 6.2 Revision History Version Date 1.0 October 2, 2012 2.0 September 18, 2013 2 CONTENTS TABLE OF CONTENTS PREFACE... 5 Purpose of this Document... 5 Version Compatibility...
Intel vpro Technology. How To Purchase and Install Symantec* Certificates for Intel AMT Remote Setup and Configuration
Intel vpro Technology How To Purchase and Install Symantec* Certificates for Intel AMT Remote Setup and Configuration Document Release Date: September 14, 2012 Revision History Revision Revision History
Realizing the Value of Intel vpro processor technology within Altiris Client Management Suite
Realizing the Value of Intel vpro processor technology within Altiris Client Management Suite Terry Cutler Enterprise Solution Architect Intel Corporation Joel Smith Principal Support Engineer Symantec
Intel Setup and Configuration Software (Intel SCS)
Intel Setup and Configuration Software (Intel SCS) Deployment Guide Version 1.0 Document Release: August 2015 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS
Configuring and Using AMT on TS140 and TS440
Configuring and Using AMT on TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES THIS PUBLICATION
Intel vpro Provisioning
Intel vpro Provisioning Introduction............................................................ 2 AMT Setup and Configuration............................................... 2 SMB Mode - AMT Setup and
Intel vpro. Technology-based PCs SETUP & CONFIGURATION GUIDE FOR
SETUP & CONFIGURATION GUIDE FOR Intel vpro Technology-based PCs This Setup Guide details what makes a true Intel vpro technology-based PC, and how to set up and configure Intel AMT (Active Management Technology)
Step-by-step Guide for Configuring Cisco ACS server as the Radius with an External Windows Database
Step-by-step Guide for Configuring Cisco ACS server as the Radius with an External Windows Database Table of Contents: INTRODUCTION:... 2 GETTING STARTED:... 3 STEP-1: INTERFACE CONFIGURATION... 4 STEP-2:
Appendix B Lab Setup Guide
JWCL031_appB_467-475.indd Page 467 5/12/08 11:02:46 PM user-s158 Appendix B Lab Setup Guide The Windows Server 2008 Applications Infrastructure Configuration title of the Microsoft Official Academic Course
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
Administration Guide. . All right reserved. For more information about Specops Deploy and other Specops products, visit www.specopssoft.
. All right reserved. For more information about Specops Deploy and other Specops products, visit www.specopssoft.com Copyright and Trademarks Specops Deploy is a trademark owned by Specops Software. All
Team Foundation Server 2012 Installation Guide
Team Foundation Server 2012 Installation Guide Page 1 of 143 Team Foundation Server 2012 Installation Guide Benjamin Day [email protected] v1.0.0 November 15, 2012 Team Foundation Server 2012 Installation
Intel Setup and Configuration Software (Intel SCS) User Guide. Version 9.0
Intel Setup and Configuration Software (Intel SCS) User Guide Version 9.0 Document Release Date: October 31, 2013 License Intel Setup and Configuration Software (Intel SCS) is furnished under license and
vpro Setup and Configuration for the 8000 Elite Business PC with Intel vpro Processor Technology
vpro Setup and Configuration for the 8000 Elite Business PC with Intel vpro Processor Technology Introduction............................................................ 2 AMT Setup and Configuration...............................................
HP Client Automation Standard Fast Track guide
HP Client Automation Standard Fast Track guide Background Client Automation Version This document is designed to be used as a fast track guide to installing and configuring Hewlett Packard Client Automation
Out-of-Band Management Reference
www.novell.com/documentation Out-of-Band Management Reference ZENworks 11 Support Pack 3 Beta February 2014 Legal Notices Novell, Inc., makes no representations or warranties with respect to the contents
ILTA HANDS ON Securing Windows 7
Securing Windows 7 8/23/2011 Table of Contents About this lab... 3 About the Laboratory Environment... 4 Lab 1: Restricting Users... 5 Exercise 1. Verify the default rights of users... 5 Exercise 2. Adding
System Area Manager. Remote Management
System Area Manager Remote Management Remote Management System Area Manager provides remote management functions for its managed systems, including Wake on LAN, Shutdown, Restart, Remote Console and for
Installation Guide. . All right reserved. For more information about Specops Deploy and other Specops products, visit www.specopssoft.
. All right reserved. For more information about Specops Deploy and other Specops products, visit www.specopssoft.com Copyright and Trademarks Specops Deploy is a trademark owned by Specops Software. All
Installing and Configuring vcloud Connector
Installing and Configuring vcloud Connector vcloud Connector 2.7.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new
ILTA 2013 - HAND 6B. Upgrading and Deploying. Windows Server 2012. In the Legal Environment
ILTA 2013 - HAND 6B Upgrading and Deploying Windows Server 2012 In the Legal Environment Table of Contents Purpose of This Lab... 3 Lab Environment... 3 Presenter... 3 Exercise 1 Add Roles and Features...
Team Foundation Server 2013 Installation Guide
Team Foundation Server 2013 Installation Guide Page 1 of 164 Team Foundation Server 2013 Installation Guide Benjamin Day [email protected] v1.1.0 May 28, 2014 Team Foundation Server 2013 Installation Guide
Pearl Echo Installation Checklist
Pearl Echo Installation Checklist Use this checklist to enter critical installation and setup information that will be required to install Pearl Echo in your network. For detailed deployment instructions
GE Healthcare Life Sciences UNICORN 5.31. Administration and Technical Manual
GE Healthcare Life Sciences UNICORN 5.31 Administration and Technical Manual Table of Contents Table of Contents 1 Network setup... 1.1 Network terms and concepts... 1.2 Network environment... 1.3 UNICORN
Step-by-step installation guide for monitoring untrusted servers using Operations Manager ( Part 3 of 3)
Step-by-step installation guide for monitoring untrusted servers using Operations Manager ( Part 3 of 3) Manual installation of agents and importing the SCOM certificate to the servers to be monitored:
Intel Active Management Technology with System Defense Feature Quick Start Guide
Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine
Intel vpro Processor Technology Setup and Configuration for the HP Z210 Workstation
Intel vpro Processor Technology Setup and Configuration for the HP Z210 Workstation Table of Contents: Introduction... 2 AMT Setup and Configuration... 2 AMT System Phases... 3 Manual Mode (SMB) AMT Setup
Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)
Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2) Hyper-V Manager Hyper-V Server R1, R2 Intelligent Power Protector Main
Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com
CHAPTER: Introduction Microsoft virtual architecture: Hyper-V 6.0 Manager Hyper-V Server (R1 & R2) Hyper-V Manager Hyper-V Server R1, Dell UPS Local Node Manager R2 Main Operating System: 2008Enterprise
Use 802.1x EAP-TLS or PEAP-MS-CHAP v2 with Microsoft Windows Server 2003 to Make a Secure Network
How To Use 802.1x EAP-TLS or PEAP-MS-CHAP v2 with Microsoft Windows Server 2003 to Make a Secure Network Introduction This document describes how to create a secure LAN, using two servers and an 802.1xcompatible
Step-by-Step Guide for Setting Up VPN-based Remote Access in a Test Lab
Página 1 de 54 Step-by-Step Guide for Setting Up VPN-based Remote Access in a Test Lab This guide provides detailed information about how you can use five computers to create a test lab with which to configure
Network DK2 DESkey Installation Guide
VenturiOne Getting Started Network DK2 DESkey Installation Guide PD-056-306 DESkey Network Server Manual Applied Cytometry CONTENTS 1 DK2 Network Server Overview... 2 2 DK2 Network Server Installation...
Intel vpro Technology. How To Purchase and Install Go Daddy* Certificates for Intel AMT Remote Setup and Configuration
Intel vpro Technology How To Purchase and Install Go Daddy* Certificates for Intel AMT Remote Setup and Configuration Revision 1.4 March 10, 2015 Revision History Revision Revision History Date 1.0 First
StarMOBILE Network Configuration Guide. A guide to configuring your StarMOBILE system for networking
StarMOBILE Network Configuration Guide A guide to configuring your StarMOBILE system for networking INTRODUCTION... 3 BEFORE YOU BEGIN... 3 1) CONFIRM YOU HAVE THE LATEST SOFTWARE... 3 2) INSTALL THE STARMOBILE
TANDBERG MANAGEMENT SUITE 10.0
TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS
F-Secure Messaging Security Gateway. Deployment Guide
F-Secure Messaging Security Gateway Deployment Guide TOC F-Secure Messaging Security Gateway Contents Chapter 1: Deploying F-Secure Messaging Security Gateway...3 1.1 The typical product deployment model...4
DriveLock Quick Start Guide
Be secure in less than 4 hours CenterTools Software GmbH 2012 Copyright Information in this document, including URL and other Internet Web site references, is subject to change without notice. Unless otherwise
Portions of this product were created using LEADTOOLS 1991-2009 LEAD Technologies, Inc. ALL RIGHTS RESERVED.
Installation Guide Lenel OnGuard 2009 Installation Guide, product version 6.3. This guide is item number DOC-110, revision 1.038, May 2009 Copyright 1992-2009 Lenel Systems International, Inc. Information
Trial environment setup. Exchange Server Archiver - 3.0
Trial environment setup Exchange Server Archiver - 3.0 Introduction This document describes how you can set up a trial environment for using Exchange Server Archiver with Exchange Server 2007. You do not
Parallels Mac Management for Microsoft SCCM 2012
Parallels Mac Management for Microsoft SCCM 2012 Administrator's Guide v3.0 Copyright 1999-2014 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Parallels IP Holdings GmbH Vordergasse
RSA Security Analytics
RSA Security Analytics Event Source Log Configuration Guide Microsoft Windows using Eventing Collection Last Modified: Thursday, July 30, 2015 Event Source Product Information: Vendor: Microsoft Event
Setting Up SSL on IIS6 for MEGA Advisor
Setting Up SSL on IIS6 for MEGA Advisor Revised: July 5, 2012 Created: February 1, 2008 Author: Melinda BODROGI CONTENTS Contents... 2 Principle... 3 Requirements... 4 Install the certification authority
ACTIVE DIRECTORY DEPLOYMENT
ACTIVE DIRECTORY DEPLOYMENT CASAS Technical Support 800.255.1036 2009 Comprehensive Adult Student Assessment Systems. All rights reserved. Version 031809 CONTENTS 1. INTRODUCTION... 1 1.1 LAN PREREQUISITES...
Step-by-Step Guide for Creating and Testing Connection Manager Profiles in a Test Lab
Step-by-Step Guide for Creating and Testing Connection Manager Profiles in a Test Lab Microsoft Corporation Published: May, 2005 Author: Microsoft Corporation Abstract This guide describes how to create
TECHNICAL DOCUMENTATION SPECOPS DEPLOY / APP 4.7 DOCUMENTATION
TECHNICAL DOCUMENTATION SPECOPS DEPLOY / APP 4.7 DOCUMENTATION Contents 1. Getting Started... 4 1.1 Specops Deploy Supported Configurations... 4 2. Specops Deploy and Active Directory...5 3. Specops Deploy
Step-by-Step Guide for Setting Up VPN-based Remote Access in a
Page 1 of 41 TechNet Home > Products & Technologies > Server Operating Systems > Windows Server 2003 > Networking and Communications Step-by-Step Guide for Setting Up VPN-based Remote Access in a Test
XMap 7 Administration Guide. Last updated on 12/13/2009
XMap 7 Administration Guide Last updated on 12/13/2009 Contact DeLorme Professional Sales for support: 1-800-293-2389 Page 2 Table of Contents XMAP 7 ADMINISTRATION GUIDE... 1 INTRODUCTION... 5 DEPLOYING
Kaseya Server Instal ation User Guide June 6, 2008
Kaseya Server Installation User Guide June 6, 2008 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private Sector IT organizations. Kaseya's
Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA 95134 USA. November 2010 202-10685-01 v1.0
Smart Control Center User Guide 350 East Plumeria Drive San Jose, CA 95134 USA November 2010 202-10685-01 v1.0 2010 NETGEAR, Inc. All rights reserved. No part of this publication may be reproduced, transmitted,
Lab 8.4.2 Configuring Access Policies and DMZ Settings
Lab 8.4.2 Configuring Access Policies and DMZ Settings Objectives Log in to a multi-function device and view security settings. Set up Internet access policies based on IP address and application. Set
Team Foundation Server 2010, Visual Studio Ultimate 2010, Team Build 2010, & Lab Management Beta 2 Installation Guide
Page 1 of 243 Team Foundation Server 2010, Visual Studio Ultimate 2010, Team Build 2010, & Lab Management Beta 2 Installation Guide (This is an alpha version of Benjamin Day Consulting, Inc. s installation
Managing Multi-Hypervisor Environments with vcenter Server
Managing Multi-Hypervisor Environments with vcenter Server vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.0 This document supports the version of each product listed and supports all subsequent
SCCM 2012. How to guide deploying SCCM Client, setting up SUP and SCEP. Hans Chr. Andersen
SCCM 2012 How to guide deploying SCCM Client, setting up SUP and SCEP Hans Chr. Andersen Contents What is Configuration Manager?... 2 Deploying SCCM Client... 3 Client push Installation... 3 SUP Installation...
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014 Version 1 NEC EXPRESSCLUSTER X 3.x for Windows SQL Server 2014 Quick Start Guide Document Number ECX-MSSQL2014-QSG, Version
ProSafe Plus Switch Utility
ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No
Step-By-Step Guide to Deploying Lync Server 2010 Enterprise Edition
Step-By-Step Guide to Deploying Lync Server 2010 Enterprise Edition The installation of Lync Server 2010 is a fairly task-intensive process. In this article, I will walk you through each of the tasks,
Tool Tip. SyAM Management Utilities and Non-Admin Domain Users
SyAM Management Utilities and Non-Admin Domain Users Some features of SyAM Management Utilities, including Client Deployment and Third Party Software Deployment, require authentication credentials with
System Center Configuration Manager 2007
System Center Configuration Manager 2007 Software Distribution Guide Friday, 26 February 2010 Version 1.0.0.0 Baseline Prepared by Microsoft Copyright This document and/or software ( this Content ) has
Installing Samsung SDS CellWe EMM cloud connectors and administrator consoles
Appendix 1 Installing Samsung SDS CellWe EMM cloud connectors and administrator consoles This section explains how you use the Cloud Management Suite installation wizard for the following purposes: To
Bluesocket virtual Wireless Local Area Network (vwlan) FAQ
Bluesocket virtual Wireless Local Area Network (vwlan) FAQ Updated 11/07/2011 Can I disable https on the login page of the BSC or vwlan and use http instead so I do not get a certificate error? No, https
Installation & Configuration Guide
Installation & Configuration Guide Bluebeam Studio Enterprise ( Software ) 2014 Bluebeam Software, Inc. All Rights Reserved. Patents Pending in the U.S. and/or other countries. Bluebeam and Revu are trademarks
Networking Best Practices Guide. Version 6.5
Networking Best Practices Guide Version 6.5 Summer 2010 Copyright: 2010, CCH, a Wolters Kluwer business. All rights reserved. Material in this publication may not be reproduced or transmitted in any form
DigitalPersona Pro Server for Active Directory v4.x Quick Start Installation Guide
DigitalPersona Pro Server for Active Directory v4.x Quick Start Installation Guide 1 of 7 DigitalPersona Pro Server for Active Directory v4.x Quick Start Installation Guide Process Overview Step Description
Administering Windows-based HP Thin Clients with System Center 2012 R2 Configuration Manager SP1
Technical white paper Administering Windows-based HP Thin Clients with System Center 2012 R2 Configuration Manager SP1 Table of contents Executive summary... 3 Configuration Manager features... 3 Asset
Table of Contents. CHAPTER 1 About This Guide... 9. CHAPTER 2 Introduction... 11. CHAPTER 3 Database Backup and Restoration... 15
Table of Contents CHAPTER 1 About This Guide......................... 9 The Installation Guides....................................... 10 CHAPTER 2 Introduction............................ 11 Required
SOLARWINDS ORION. Patch Manager Evaluation Guide for ConfigMgr 2012
SOLARWINDS ORION Patch Manager Evaluation Guide for ConfigMgr 2012 About SolarWinds SolarWinds, Inc. develops and markets an array of network management, monitoring, and discovery tools to meet the diverse
Installing and Configuring WhatsUp Gold
Installing and Configuring WhatsUp Gold This guide provides information about installing and configuring WhatsUp Gold v14.2, including instructions on how to run the WhatsUp web interface through an Internet
FieldIT Limited www.fieldit-limited.com. FieldIT CRM. Installation Manual v1.3.i3 (Enterprise Install)
FieldIT Limited www.fieldit-limited.com FieldIT CRM Installation Manual v1.3.i3 (Enterprise Install) Oliver Field FieldIT Limited 2013 13 Introduction The FieldIT CRM software can be installed in several
DameWare Server. Administrator Guide
DameWare Server Administrator Guide About DameWare Contact Information Team Contact Information Sales 1.866.270.1449 General Support Technical Support Customer Service User Forums http://www.dameware.com/customers.aspx
Getting Started. Symantec Client Security. About Symantec Client Security. How to get started
Getting Started Symantec Client Security About Security Security provides scalable, cross-platform firewall, intrusion prevention, and antivirus protection for workstations and antivirus protection for
Installation Instruction STATISTICA Enterprise Server
Installation Instruction STATISTICA Enterprise Server Notes: ❶ The installation of STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation installations on each of
Universal Management Service 2015
Universal Management Service 2015 UMS 2015 Help All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording,
Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.
Important Please read this User s Manual carefully to familiarize yourself with safe and effective usage. About This Manual This manual describes how to install and configure RadiNET Pro Gateway and RadiCS
SafeGuard Enterprise Installation Best Practice
SafeGuard Enterprise Installation Best Practice Product Version: 7 Document date: December 2014 Contents www.utimaco.c om Introduction... 4 Technical prerequisites... 5 Installation order... 6 1. Installing
Sophos for Microsoft SharePoint startup guide
Sophos for Microsoft SharePoint startup guide Product version: 2.0 Document date: March 2011 Contents 1 About this guide...3 2 About Sophos for Microsoft SharePoint...3 3 System requirements...3 4 Planning
Synchronizer Installation
Synchronizer Installation Synchronizer Installation Synchronizer Installation This document provides instructions for installing Synchronizer. Synchronizer performs all the administrative tasks for XenClient
Installation Guide: Delta Module Manager Launcher
Installation Guide: Delta Module Manager Launcher Overview... 2 Delta Module Manager Launcher... 2 Pre-Installation Considerations... 3 Hardware Requirements... 3 Software Requirements... 3 Virtualisation...
AMT Implementation on a UTC RETAIL 3170 POS
AMT Implementation on a UTC RETAIL 3170 POS Controlling POS systems using Intel AMT Features UTC RETAIL 1 November 19, 2012 Scope The document was written for use by UTC RETAIL 3170 POS customers to enable
Sharpdesk V3.5. Push Installation Guide for system administrator Version 3.5.01
Sharpdesk V3.5 Push Installation Guide for system administrator Version 3.5.01 Copyright 2000-2015 by SHARP CORPORATION. All rights reserved. Reproduction, adaptation or translation without prior written
Quick Start guide to. Microsoft Business Solutions CRM 1.2. on a Microsoft Windows Small Business Server 2003 Premium Edition.
Quick Start guide to Microsoft Business Solutions CRM 1.2 on a Microsoft Windows Small Business Server 2003 Premium Edition M Partner Program Welcome! There are many resources available to help you install
Quick Start Guide for Parallels Virtuozzo
PROPALMS VDI Version 2.1 Quick Start Guide for Parallels Virtuozzo Rev. 1.1 Published: JULY-2011 1999-2011 Propalms Ltd. All rights reserved. The information contained in this document represents the current
523 Non-ThinManager Components
28 Non-ThinManager Components Microsoft Terminal Servers play an important role in the ThinManager system. It is recommended that you become familiar with the documentation provided by Microsoft about
Managing Software Updates with System Center 2012 R2 Configuration Manager
Managing Software Updates with System Center 2012 R2 Configuration Manager Managing Microsoft Updates with Configuration Manager 2012 R2 This document is for informational purposes only. MICROSOFT MAKES
Table of Contents. Introduction...9. Installation...17. Program Tour...31. The Program Components...10 Main Program Features...11
2011 AdRem Software, Inc. This document is written by AdRem Software and represents the views and opinions of AdRem Software regarding its content, as of the date the document was issued. The information
Tenrox. Single Sign-On (SSO) Setup Guide. January, 2012. 2012 Tenrox. All rights reserved.
Tenrox Single Sign-On (SSO) Setup Guide January, 2012 2012 Tenrox. All rights reserved. About this Guide This guide provides a high-level technical overview of the Tenrox Single Sign-On (SSO) architecture,
EntroWatch - Software Installation Troubleshooting Guide
EntroWatch - Software Installation Troubleshooting Guide ENTROWATCH SOFTWARE INSTALLATION TROUBLESHOOTING GUIDE INTRODUCTION This guide is intended for users who have attempted to install the EntroWatch
026-1010 Rev 7 06-OCT-2011. Site Manager Installation Guide
026-1010 Rev 7 06-OCT-2011 Site Manager Installation Guide Retail Solutions 3240 Town Point Drive NW, Suite 100 Kennesaw, GA 30144, USA Phone: 770-425-2724 Fax: 770-425-9319 Table of Contents 1 SERVER
Installing and Configuring Login PI
Installing and Configuring Login PI Login PI Hands-on lab In this lab, you will configure Login PI to provide performance insights for a Windows Server 2012 R2 Remote Desktop Services installation. To
ms-help://ms.technet.2005mar.1033/security/tnoffline/security/smbiz/winxp/fwgrppol...
Page 1 of 16 Security How to Configure Windows Firewall in a Small Business Environment using Group Policy Introduction This document explains how to configure the features of Windows Firewall on computers
Contents Introduction... 3 Introduction to Active Directory Services... 4 Installing and Configuring Active Directory Services...
Contents 1. Introduction... 3 1.1. Setup... 3 2. Introduction to Active Directory Services... 4 3. Installing and Configuring Active Directory Services... 5 3.1. Joining to Domain... 5 3.2. Promoting Member
Kaspersky Lab Mobile Device Management Deployment Guide
Kaspersky Lab Mobile Device Management Deployment Guide Introduction With the release of Kaspersky Security Center 10.0 a new functionality has been implemented which allows centralized management of mobile
How To Create An Easybelle History Database On A Microsoft Powerbook 2.5.2 (Windows)
Introduction EASYLABEL 6 has several new features for saving the history of label formats. This history can include information about when label formats were edited and printed. In order to save this history,
DESLock+ Basic Setup Guide Version 1.20, rev: June 9th 2014
DESLock+ Basic Setup Guide Version 1.20, rev: June 9th 2014 Contents Overview... 2 System requirements:... 2 Before installing... 3 Download and installation... 3 Configure DESLock+ Enterprise Server...
Windows Server 2008 R2 Initial Configuration Tasks
Windows Server 2008 R2 Initial Configuration Tasks I am not responsible for your actions or their outcomes, in any way, while reading and/or implementing this tutorial. I will not provide support for the
Installation and Configuration Guide
Entrust Managed Services PKI Auto-enrollment Server 7.0 Installation and Configuration Guide Document issue: 1.0 Date of Issue: July 2009 Copyright 2009 Entrust. All rights reserved. Entrust is a trademark
Remote Support Jumpoint Guide: Unattended Access to Computers in a Network 3. Requirements and Considerations to Install a Jumpoint 4.
Jumpoint Guide 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property of their respective owners.
Freshservice Discovery Probe User Guide
Freshservice Discovery Probe User Guide 1. What is Freshservice Discovery Probe? 1.1 What details does Probe fetch? 1.2 How does Probe fetch the information? 2. What are the minimum system requirements
safend a w a v e s y s t e m s c o m p a n y
safend a w a v e s y s t e m s c o m p a n y SAFEND Data Protection Suite Installation Guide Version 3.4.5 Important Notice This guide is delivered subject to the following conditions and restrictions:
MGC WebCommander Web Server Manager
MGC WebCommander Web Server Manager Installation and Configuration Guide Version 8.0 Copyright 2006 Polycom, Inc. All Rights Reserved Catalog No. DOC2138B Version 8.0 Proprietary and Confidential The information