1 Murray Electrical Products SPEEDFAX TM 207 Section Rock Solid Load Center Siemens would like to welcome the Murray Electrical Products into the Speedfax. The Murray Electrical Products catalog and Siemens Speedfax has been combined for our customer s convenience. All of the Murray-branded product is located in section so Murray customers will not have to sort thru the entire Speedfax to find associated products. Customers can now select Murray and Siemens products without having to flip between catalogs. Murray products have a rich tradition of quality & reliability that still lives on today. At the heart of the Murray offering is the Rock Solid load center designed for those customers that prefer an out-board neutral design & metal basepan for installing breakers. The Rock Solid load center & Murray products remain an important part of the Siemens portfolio. Siemens is proud to carry on the tradition Murray started in 899. MURRAY 2-pole Combo AFCI Circuit reaker C o n t e n t s Load Centers -2-2 Circuit reakers Arc-Fault Interrupters (AFCI) - " Plug-in -4-5 Circuit reaker and Surge Protective Device (SPD) -6 Special Application reakers -7 Type MSQ, /4 Inch Plug-In reakers -8 Main and ranch Circuit reakers -9 Accessories Line Diagrams and Lug Data Combination Meter Sockets A-400A Meter Mains A-200A Over-Under Construction A-400A Meter Load Centers A-400A EUSERC Side-y-Side Construction A-225A EUSERC Meter Load Center A EUSERC Side-y-Side Construction - Group Metering: NYC Gangable Metering - -7 General Duty Compact Safety Switch Scan to connect online to the most up-todate version of this Section of SPEEDFAX. Safety Switches General Information -8 Technical Information -9 General Duty Compact -40 Stand-by Power Switches -40 General Duty Switches -4 Heavy Duty Switches VII Type Double Throw Switches -45 Protector-Lock Switches -46 Accessories and Lug Data Dimensions and Knockout Diagrams Siemens Industry, Inc. SPEEDFAX 207 Product -

2 Rock Solid Load Centers Revised on /0/7 Features The Murray Rock Solid Load Center is the highest quality, most versatile design in the industry. Features on the Rock Solid Load Center include: MURRAY Load Centers. Swiss Cheese style neutral bars provide multiple /0 connection points. 2. All units include factory installed ground bar and isolated neutral.. With the use of the included bonding strap, ground bars and neutral bars can be bonded for service entrance applications. 4. Outboard neutral and groundbars allow for all neutral and ground connections to be located away from breaker connections, making for a neat, clean installation. 5. Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws. 6. Combination head screw on trim and upper pan screws provide installation flexibility. 7. Main breaker devices are convertible to main lug with the addition of main lug kits All main breakers are straight in wired no back feeding required. 9. A rigid, sturdy base pan with metal hook rails provides the most rugged breaker connection in the industry. 0. The outdoor enclosure has a slide hinge door for the easiest of installation and can be removed by backing out only one screw. 5. All indoor Rock Solid Load Centers are invertible for bottom feed applications. 7 8 The following offering is available in the Murray line: n 2-60 Circuits/Spaces n Indoor and outdoor enclosures n 00 to 225 Amp n Main lug and main breaker n Value packs - a mix of branch breakers provided with the load center Siemens Industry, Inc. SPEEDFAX 207 Product

3 Rock Solid Load Centers f Revised on /0/7 Main Lug Only, Ø, 65,000 AIC a, Main Lug Panels -Wire 20/240V AC or 208Y/20V AC, Insulated and onded Split Neutrals Load centers on this page through 225 amp feature a split neutral insulated bars. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bars for neutral conductors and bonded bar for ground conductors. LW2040L Circuit, Amperes Amps Max. No. of Spaces Max. Circuit Indoor Type b Dimensions c Outdoor Type R bd Dimensions c Height g Width Depth Height Width Depth LC224L LW224L LC62L LW62L LC2040L LW2040L LC040L LC62L LC2440L LW224L LC2040L LW2040L LC2440L LC040L LW040L LC4040L LC4060L MURRAY Load Centers Copper us e Amps Max. No. of Spaces Max. Circuit Indoor Type b Dimensions c Outdoor Type R b Dimensions c Height g Width Depth Height Width Depth LC2040L25CU LC2040L200CU LC040L200CU LC4040L200CU LW224L225CU LC4242L225CU LW4242L225CU a A only. b Standard package quantity equal to. c Dimensions shown are representative of outside box length, width & depth (± 8 ) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 4 additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required. d Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub. See accessories page -8 for hub selection. e Copper bus load centers are recommended for those applications where the environment may be severe (ie farm and coastal areas). f Units manufactured after April 0, 204 are UL listed for Siemens and Murray reakers g Heights shown are for Series A. Original series heights are listed on page -0. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -

4 Rock Solid Load Centers Revised on /0/7 Main reaker, Ø, 22,000 AIC Load centers on this page through 200 amp feature a new split neutral with one bonded and one insulated bar. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bar for neutral conductors and bonded bar for ground conductors. MURRAY Load Centers LC Load Center Short Circuit Current Rating Murray load centers have UL recognized short circuit current ratings up to 00,000 Amps, when used with appropriate main or feeder (remote or internal) overcurrent devices. Load center ratings are shown below. For load center applications with residential or commercial metering equipment, refer to the appropriate catalog section. Load Center Short Circuit Current Rating Load Center Internal or Remote Short Circuit Load Center Main or Feeder Current Rating b Main Rating Circuit reaker Type 0,000 AIC Any Any 22,000 AIC 00/25A MP-HT, MQH c 50/200/225A MD-H, MQH b, MPP-HT 42,000 AIC 00/25A MQL c 50/200/225A MQL b 65,000 AIC 00/25A MP-MT, MPP-MT 50/200/225A MPP-MT 00,000 AIC 00/25A 00A, 00V AC, Class T Fuse 00,000 AIC 50/200/225A 200A, 00V AC, Class T Fuse Ø, main breaker load centers are Underwriter s Laboratories Listed for use with 60/75 C conductors and accept Murray branch circuit breakers which are also UL Listed for use with 60/75 C conductors. Type R load centers are furnished with a hub opening closure plate Circuit, Amperes Amps Max. No. of Spaces Max. Circuit Dimensions Outdoor Type R Dimensions Indoor Type Height j Width Depth Height Width Depth LC LW LW LC LC LC LC LC LW LC LC LW LC LC LW LC LC LW LC LW LC LC LC Copper us Amps No. of Max. Indoor Type Dimensions Max. Spaces Circuit Height j Width Depth LC204000CU LC CU LC040200CU LC CU A only. b This information is based on use of 0,000 AIC rated branch circuit breakers in load center (MP-T, MH-T, MP-GT, MG). Most series ratings exclude MH-T above 40 Amp. Consult device wiring diagram for specific data. Remote Only Types MQH & MQL may be mounted internal in amp Ø main breaker load centers. Dimensions shown are representative of outside box length, width & depth (± 8 ) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 4 additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required. Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub. Standard package quantity equal to. Copper bus load centers are recommended for those applications where the environment may be severe (ie farm and coastal areas). Units manufactured after April 0, 204 are UL listed for Siemens and Murray reakers Heights shown are for Series A. Original series heights are listed on page Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

5 Load Centers Generator Ready, Riser, & 400A Load Centers NEMA Generator Ready Generator Ready Load Centers (phase) NEMA R Generator Ready Generator Ready Load Center Features n UL Listed n Indoor Type and outdoor Type R n 225A max rated n Flush or surface mounting n Fits between standard stud centers n Tin plated copper bus bars n 22 kaic rated n 20/240V ~ n Main lug convertible to main breaker with addition of MK50M, MK200M, or MK225M n Main breaker convertible to main lug with use of lug kit part no. ECMLK225 n Installation of transfer mechanism can be performed at time of generator installation ranch Circuits Indoor Enclosure - NEMA Type Outdoor Enclosure - NEMA Type R No. of No. of Dimensions (inches) Dimensions Amp Rating Spaces Circuits H W D H W D LC042200GEN LW042200GEN MURRAY Load Centers LC042L225GEN LW042L225GEN Riser Load Centers Amp Rating 400A Main reaker Load Centers (phase & phase) No. of Phases Amp Rating No. of Spaces No. of Circuits No. of Spaces No. of Circuits Dimensions (inches) H W D Acceptable Main reaker Kits RC62L25CU MK00M, MK25M RC2424L25CU MK00M, MK25M RC2442L25CU MK00M, MK25M RC042L200CU MK50M, MK200M Dimensions (inches) Dimensions H W D H W D LC0SS LW442SR LP442SS LZ442SR A Main Lug Load Centers (phase & phase) No. of Phases Amp Rating No. of Spaces No. of Circuits Dimensions (inches) Dimensions H W D H W D LW042SR LC042SS LW942SR LC042SS 2 spaces and 2 circuits are reserved for standby generator installation. 400 amp load centers have insulated groundable center-mounted neutrals. See Section for knock-out diagram. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -5

6 Load Centers Circuit reaker Enclosures & Small Load Centers n Ideal for Narrow stud applications n Eliminated notching needed for standard Load Centers n Outdoor Load Center with factory installed Ground Fault reaker n Two extra circuits n Factory installed feed-through lugs n Main reaker or Main Lug panels available LC002GS LC004NS MURRAY Spa Panels Load Centers Ampere Rating No. of Spaces Max. Circuits Dimensions c Height Width Depth LW004NRSPA50 m LW004NRSPA60 n Renovation Panels - Wire 20/240V AC LC024PFR LC0DFCGP l Outdoor a Trailer Panels - 20/240V AC 208Y/20V AC Amps No. of Max. Indoor Type Dimensions c Max Spaces Circuits No. Height Width Depth Main reaker LW02NL k MP200 Factory LW204TL k MPD2200R Factory LW004TR j MD-T(R), MD-HT(R) Field LW086L200TR j MK50M or MK200M Field 2-8 Circuit, Amperes (no door) Amps Max. No. of Spaces Max. Circuit Indoor Type Dimensions c Outdoor Type R a Dimensions c b Height Width Depth Height Width Depth LC002GS LW002GR LP00CS LC002HS LW002HR LC004NF LC004NS LW004NR LC004VS LW004VR LW002QR Circuit, 25 Amperes (with door) LC008DF LC008DS LW008NR LC008DFG LC008DSG Enclosed reakers LC00CS LW00CR LC200VS LW200VR LW90QR a Hub provision only. Closure plate included. Panels through 225A require HS type hub. b Cover type is specified by character in 7th (usually last) position, as follows: S = Surface F = Flush C = Combination Surface/Flush c Dimensions shown are representative of outside box length, width & depth (± 8 ) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 4 additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required. d Use of 60A GFCI requires use of 75 C copper wire. e Use neutral lug kit ECLK or ECLK2 as required. f Panel includes factory-installed ground bar. g Maximum breaker 00A. h Uses HA type hub. Closure plate included. For KO diagram, see Section KO diagram for W0204ML060 i Accepts type MQ breakers. j For service entrance use only 200A max. main breaker. Main breaker must be field added. k LW02NL shipped with ECHS25 hub instead of closure plate. LW204TL shipped with ECHS200 hub instead of closure plate. l Two MP5 and one MP20 provided. m 50 Amp, 2-pole GFCI breaker installed. n 60 Amp, 2-pole GFCI breaker installed. Uses ECHA hub type. -6 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

7 Load Centers Load Center OEM Interiors Ø: Small Circuit Main Lug Interiors Dimensions Amps a Circuits Spaces Height Width 60 I0204ML I00ML I0408ML I086ML25CU I086ML25CUSP I0202L Small circuit Interiors The small circuit interiors are ideal for OEM applications requiring only a few circuits. They can also be purchased as replacement items for: I0204ML25 Interior for LC00CS, LW00CR I00ML00 Interior for LP00CS I0408ML25 Interior for L(C,W)004N(F,S,R) I086ML25CU Interior for L(C,W)008D(F,S,R) I0202L200 Interior for JC0202 Meter Mains Rock Solid Ø: High Circuit Main Lug Interiors (no neutrals) c W Dimensions Amps a Circuits Spaces Height Width 25 IR224L IR62L IR2040L25CU IR040L IR086L200TR b IR2040L200CU IR2440L IR040L200CU IR4040L200CU IR4242L225CU Lug Data Interior Amperage Wire range Torque I0204ML /0-4 AWG 45 lb. - ins. I00ML /0-4 AWG 45 lb. - ins. I224ML /0-4 AWG 45 lb. - ins. I0408ML /0-4 AWG 45 lb. - ins. I086ML25CU/CUSP 60 2/0-4 AWG 45 lb. - ins. Rock Solid 25 2/0-4 AWG 0 lb. - ins. Rock Solid 200/ kcmil - 4 AWG 275 lb. - ins. H H I0204ML25 W I086ML25CU H W Rock Solid W MURRAY Load Centers W H H I0202L200 I0408ML25 a The letters CU in any catalog number represent copper bus bars. b Feed thru lugs provided c Convertible to main breaker using the MK main breaker kits Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -7

8 Load Centers Electricenter Accessories Hubs Description Pack Quanity ECHS075 4 Hub 0 ECHS00 Hub 0 ECHS25 4 Hub 0 ECHS50 2 Hub 0 ECHS200 2 Hub 0 ECHS Hub 0 MURRAY ECHS25 ackfed Main reaker Hold Down Kits ECMR2 ECMR ECLX86HD Description Pack Quanity ECMR2 For use on MP-T, MP-HT, & MP-MT breakers in Rock Solid Load Centers 25 ECMR For use on MP-T, MP-HT, & MP-MT breakers in 2 8 circuit Load Centers 25 ECLX78M For use on MD-T, MD-HT, & MD-MT breakers on old style (pre 200) load centers (2 42 circuit) 25 ECLX86HD For use on MP-T, MP-HT, & MP-MT breakers (5 60A) on old style (pre 200) load centers 25 (2 42 circuit) ECLX87HD For use on MP-T, MP-HT, & MP-MT breakers (70 25A) on old style (pre 200) load centers 25 (2 42 circuit) ECLX88HD For use on MP-T, MP-HT, & MP-MT breakers (00 25A) on old style (pre 200) load centers (2 42 circuit) 25 Load Centers ECLX87HD Miscellaneous ECLX88HD Description Pack Quanity ECQFL2 Door lock for Rock Solid Load Centers 0 ECQF Filler plate ( ) 0 ECMF25 Filler plate for main breaker opening on 00 25A Rock Solid Load Centers. Use two QF 25 filler plates for A load centers LX077SF Flush installation cover for 400A panels ECTS2 6 Cover screws, combination cover 50 ags ECSMK Surface mount spacer kit provides 4 space between load center and wall 25 ECQFL2 Main reaker Kits QF/ECQF Description Pack Quanity MK00M 00A For use on 00 & 25A Rock Solid Load Centers only MK25M 25A For use on 25A Rock Solid Load Centers only MK50M 50A For use on 50, 200, & 225A Rock Solid Load Centers only MK200M 200A For use on 200 & 225A Rock Solid Load Centers only MK225M 225A For use on 225A Rock Solid Load Centers only ECMLK25 PH Main Lug Conversion Kit 00-25A ECMLK225 PH Main Lug Conversion Kit A Description Pack Quanity ECLK2SC #2/0 max. lug for 25 amp neutral feeder for 2 42 circuit devices 50 ECLX84M C enclosure ground lug 20 MK00M MK200M Lug Kits Ground ars and Insulated Neutral Kits Insulated Neutral Kit Description Pack Quanity ECLX068M 4 small terminals 5 8 long 0 ECLX069M 5 small and 2 large terminals long 0 ECLX07M 8 small and large terminals 2 long 0 ECLX072M small and 4 large terminals 45 8 long 0 ECLX07M 4 small amd 5 large terminals 5 4 long 0 ECLX074M 7 small amd 6 large terminals 7 long 0 ECLX075M 2 small amd 7 large terminals 8 long 0 ECINSN27 Insulated neutral bar with 27 positions 0 ECINSN2 Insulated neutral bar with 2 positions 0 ECINSN Insulated neutral bar with positions and a 00 MCM lug 0 ECINSN4 Insulated neutral bar with 4 positions and a 00 MCM lug 0 ECINSN4 Insulated neutral bar with 4 positions 0-8 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

9 Load Centers Logic Rock Solid Load Centers LC 0 40 L 200 CU CU = Copper us ar T = Feed Thru Lugs P = Value Pack Main Ampere Rating Circuits (max. No. of circuits) Spaces (max. No. of breakers) = Ø = Ø L = Main Lug = Main reaker MURRAY Load Centers LC = Indoor Load Center LW = Outdoor Load Center - Type R Lug Data Amps Phase Wire Range a Main Lug Load Centers Main reaker Load Centers 060 Ø Ø -/0 25 (4 CKT) Ø 4-2/0 25 (6 CKT & Above) Ø 4-2/0 4-2/0 50 Ø /0-4/ kcmil Amps Phase Wire Range a Main Lug Load Centers Main reaker Load Centers 200 Ø kcmil kcmil 225 Ø 4-00 kcmil 4-00 kcmil 400 (24 and 42 CKT) Ø ()/0-500 kcmil b (or2)/0-250 kcmil (2)/0-250 kcmil 400 (0 CKT Only) Ø ()/0-500 kcmil (2)/0-250 kcmil 400 (24 and 42 CKT) Ø ()/0-500 kcmil b (2)/0-250 kcmil a All lugs are rated for Cu or AI wire. Wire rang shown is maximum allowable for bending space provided. Lug may accommodate larger wire. Refer to National Electric Code for specific wire size requirements. b 500 kcmil must be top side entry. Siemens Industry, Inc. SPEEDFAX 207 Product -9

10 Murray Load Centers Revised on /0/7 Cross References MURRAY Load Centers Murray -Phase Cross Reference to New SKUs (See Section for full offering) Legacy Murray SKU ES Series Part No. PL Series Part No. LC22400CU S22400 P22400CU LC224L25CU S224L25 P224L25CU LC224L200CU S224L200 No equivalent LC8600CU No equivalent No equivalent LC86L50CU S86L50 No equivalent LC86L200CU S2442L200 No equivalent LC2442L50CU S2442L50 P2442L200CU LC04250CU S P424250CU LC042200CU S P054200CU LC042L200CU S054L200 P054L200CU LC CU S P CU LC CU S P TCU/P CU LC4242L225CU S4260L225 P4260L225CU LW224L25CU SW224L25 PW224L25CU LW86L50CU SW86L50 No equivalent LW042200CU SW PW054200CU LW042L200CU SW054L200 PW054L200CU New S04200 New S5470L225 New SW224L200 New SW2442L50 New SW2442L200 New SW4260L225 New S0000 New SW New SW New SW New P04200CU New Murray Heights Height Load Center Original Series A LC LC224L LC224L25P 2 8 LC LC LC62L LC62L LC LC204000CU 24 2 LC204000P 24 2 LC LC LC CU 0 0 LC P 0 0 LC2040L LC2040L25CU 24 2 LC2040L LC2040L200CU 0 24 LC LC LC LC2440L LC2440L LC LC244800P LC LC LC LC040200CU 6 6 LC040200P 6 6 LC040L LC040L LC040L200CU 6 0 LC LC060200P 6 6 LC LC CU 9 6 LC P 9 6 LC4040L LC4040L200CU 9 6 LC LC4060L LC4242L225CU 42 9 LC LC P Siemens Industry, Inc. SPEEDFAX 207 Product

11 Knockout Diagrams Rock Solid Load Centers (including Generator Ready) Indoor Main reaker and Main Lug Enclosures Outdoor Main reaker and Main Lug Enclosures 2 K.O.s For.08, 0.5, 0.75,,.25 Conduit 4 K.O.s For 0.25 Conduit 0 K.O.s For 0.5, 0.75, Conduit 4 K.O.s For,.5, 2, 2.5 Conduit 2 K.O.s For.08, 0.5, 0.75 Conduit 0 K.O.s For,.25, 2, 2.5 Conduit 52 K.O.s For 0.5 Conduit 2 K.O.s For 0.5 Conduit 8 K.O.s For 0.5, 0.75 Conduit 4 Circuit Indoor 8 Circuit Indoor 6 Circuit Indoor 4 K.O.s For,.5 Conduit K.O. dimensions refer to conduit trade size, not actual diameter. MURRAY Load Centers W D W D W D C A Q A A A A A A A A A N A C C C M A Q A M N C N C N L L L C C M R M C N C C A Q A N A A A A A A A A C A Knockout Code Conduit Sizes g = 4 S =, 4, 2, 2, 2 2 A = 2 T = 4 = 2, 4 U = 4, 2 C = 2, 4, V = 4, 2, 2 D = 2, W = 4, 2 E = 2, 4,, 4 X = 4, 2, 2, 2 2 F = 2, 4, 2 Y = 2, 2 G = 4 Z = 2, 2, 2 2 H = 4, AA = 2, 2, 2 2, J = 4,, 4 = 2, 2, 2 2,, 2 K = 4, 4 CC = 2, 2 2,, 2 L = 2, 4,, 4, 2 EE = 2, 2 2, M = 4,, 4, 2 FF = 2 2, N = 4,, 4, 2, 2 GG = 2 2,, 2 P =, 4 HH = 2 2,, 2, 4 Q =, 4, 2 JJ = 2, 4 R =, 4, 2, 2 LL = VV = 2 Siemens Industry, Inc. SPEEDFAX 207 Product -

12 Knockout Diagrams Indoor and Outdoor Enclosures 400A Indoor 400A Outdoor W D W D E E GG GG E E HV HV L L MURRAY GG GG E E E E E GG GG E E E Load Centers 8 Circuit Outdoor W HS D 4 Circuit Outdoor W HS D L L M M M C C M C C Knockout Code Conduit Sizes g = 4 S =, 4, 2, 2, 2 2 A = 2 T = 4 = 2, 4 U = 4, 2 C = 2, 4, V = 4, 2, 2 D = 2, W = 4, 2 E = 2, 4,, 4 X = 4, 2, 2, 2 2 F = 2, 4, 2 Y = 2, 2 G = 4 Z = 2, 2, 2 2 H = 4, AA = 2, 2, 2 2, J = 4,, 4 = 2, 2, 2 2,, 2 K = 4, 4 CC = 2, 2 2,, 2 L = 2, 4,, 4, 2 EE = 2, 2 2, M = 4,, 4, 2 FF = 2 2, N = 4,, 4, 2, 2 GG = 2 2,, 2 P =, 4 HH = 2 2,, 2, 4 Q =, 4, 2 JJ = 2, 4 R =, 4, 2, 2 LL = VV = 2-2 Siemens Industry, Inc. SPEEDFAX 207 Product

13 Circuit reakers Arc-Fault Circuit Interrupters (AFCI) Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc fault is detected Combination Type AFCI b Detects all three possible types of arc faults: line-to-ground, line-to-neutral, and series. reaker Type MP-AT2/MP-HAT2/ MP-MAT2 -Pole 20V AC MP-AT2/MP-HAT2 2-Pole 20/240V AC Ampere Rating ranch-feeder AFCI Detects line-to-ground and line-to-neutral arcs. MP-AT2/MP-HAT2/ MP-MAT2 -Pole 20V AC ,000 A IR MPA5AFC a MPA20AFC a MP25AFC a MP220AFC a MPA5AF a MPA20AF a 22,000 A IR MPA5AFCHn a MPA20AFCHn a MP25AFCHn a MP220AFCHn a MPA5AFH n a MPA20AFH n a 65,000 A IR MPA5AFCHH MPA20AFCHH MPA5AFHH MPA20AFHH NEW Dual Function AFCI/GFCI The Dual Function Circuit reaker combines Combination Type AFCI and GFCI, protecting against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test feature, making it the first in class in electrical safety for homeowners. MP-GAT2/MP-HGAT2/ MP-MGAT2 -Pole 20V AC 5 20 MP5DF MP20DF MP5DFH MP20DFH Ground Fault Interrupters and Protection Ground-Fault Circuit Interrupters (Class A - 5mA) b Ground-fault circuit interrupters (GFCI) provide Class A ground fault protection. A GFCI is a device intended for personnel protection and will de-energize the circuit when a fault current to ground is 6 milliamperes or more. MP5DFM MP20DFM Ground Fault Equipment Protection (0mA) b Type EQF circuit breakers provide protection of equipment from damaging line-to-ground fault currents by de-energizing the circuit for all ungrounded conductors of the faulted circuit. UL Listed HACR Rated (Except where noted) Standard inch per pole format with plug-in design -Pole Combination Type AFCI -Pole ranch Feeder AFCI 2-Pole Combination Type AFCI MURRAY Circuit reakers reaker Type MP-GT/ MP-HGT -Pole 20V AC MP-GT/ MP-HGT 2-Pole a 20/240V AC Amp 0,000 A IR Rating No. 22,000 A IR No. 5 MP5GFA MP5GFAHn 20 MP20GFA MP20GFAHn 25 MP25GFA MP25GFAHn 0 MP0GFA MP0GFAHn 5 MP25GFA MP25GFAPn 20 MP220GFA MP220GFAPn 0 MP20GFA MP20GFAPn 40 MP240GFA MP240GFAPn 50 MP250GFA MP250GFAPn 60 MP260GFA MP260GFAPn reaker Type MP-ET/ MP-HET -Pole 20V AC MP-ET/ MP-HET 2-Pole a 20/240V AC Amp 0,000 A IR Rating No MP5EG a MP20EG a MP0EG 22,000 A IR No. MP5EGH n a MP20EGH n a MP0EGH n 5 MP25EG MP25EGH n 20 MP220EG MP220EGH n 0 MP20EG MP20EGH n 40 MP240EG MP240EGH n 50 MP250EG MP250EGH n 60 MP260EG n MP260EGH n -Pole GFCI 2-Pole GFCI AFCI and GFCI Accessories Description Padlocking Device for & Twin reakers Padlocking Device for 2 & Quad reakers Handle locking Device for /2 Circuit reakers ECPLD ECPLD2 ECX2M n uilt to order. Allow 8-0 weeks for delivery. a Not UL Listed as SWD Rated. b White line neutral (pigtail) must be connected to the panel neutral for the device to function. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -

14 Circuit reakers Full Size (" per Pole) with INSTA-WIRE MURRAY Circuit reakers Continuous Current 40 C Type MP-T Type MP-HT Type MP-MT 0,000A IR 22,000A IR 65,000A IR -Pole Plug-In (20V AC) e 0 MP0 5 MP5 d MP5KH d MP5KMn d 20 MP20 d MP20KH d MP20KMn d 25 MP25 MP25KHn MP25KMn 0 MP0 MP0KH MP0KMn 5 MP5n MP5KHn MP5KMn 40 MP40 MP40KH MP40KMn 45 MP45n MP45KHn MP45KMn 50 MP50 MP50KH MP5KKMn 60 MP60n MP60KHn MP60KMn 70 MP70n MP70KHn MP70KMn 2-Pole Plug-In (Common-Trip 20/240V AC ) f 5 MP25 MP25KH MP25KMn 20 MP220 MP220KH MP220KMn 25 MP225 MP225KHn MP225KMn 0 MP20 MP20KH MP20KMn 5 MP25 MP25KHn MP25KMn 40 MP240 MP240KH MP240KMn 45 MP245 MP245KHn MP245KMn 50 MP250 MP250KH MP250KMn 60 MP260 MP260KH MP260KMn 70 MP270 MP270KHn MP270KMn 80 MP280 MP280KHn 90 MP290 MP290KHn MP290KMn 00 MP200 MP200KH MP200KM 0 MP20 MP20KH MP20KMn 25 MP225 MP225KH MP225KM 2-Pole Plug-In (Common-Trip 240V AC) cf 5 MPH25 20 MPH220 0 MPH20 40 MPH240n 50 MPH MPH MPH270n 00 MPH200n -Pole Plug-In (Common-Trip 240V AC) g 5 MP5 MP5KH MP5KMn 20 MP20 MP20KH MP20KMn 25 MP25n MP25KHn 0 MP0 MP0KH MP0KM 5 MP5n 40 MP40 MP40KH MP40KM 45 MP45n 50 MP50 MP50KH MP50KM 60 MP60 MP60KH MP60KM 70 MP70 MP70KH MP70KMn 80 MP80 MP80KHn MP80KMn 90 MP90 MP90KHn MP90KMn 00 MP00 MP00KH MP00KM -Pole 2-Pole -Pole Wiring Diagrams MP-T / MP-HT / MP-MT Internal Accessories Description Field/Factory Installed 20V Shunt Trip add suffix...stn Factory 24V Shunt Trip add suffix...st24vn Factory 20V Auxiliary Switch add suffix...asn b Factory Modifications Description 400Hz Calibration Marine 50 C Ambient Calibration Fungus Proofing add suffix...y h add suffix...m add suffix...f For external accessories please refer to page -20. n uilt to order. Allow 2- weeks for delivery a UL Listed for use with 60/75 wire through 40 amps, UL listed for use with 75 wire only for 50 amps and above, HACR rated. 20V AC Fluorescent Lighting. b A and contacts. c UL Listed for use on phase grounded systems 0,000 for this application. d UL Listed for frequent switching applications (SWD). e Shipped 2 per sleeve. f Shipped 6 per sleeve. g Shipped 4 per sleeve. h UL Listed 5KA IR. i Not UL Listed. j & 2 Poles only. -4 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

15 Circuit reakers Duplex, Triplex and Quadplex Plug-in reakers Duplex Circuit reakers reaker Type MH-T -Pole 0K AIC 20V AC Ampere Rating 5 5 MP55 MP55Na 5 20 MP520 MP520Nna MP2020 MP2020Na 20 0 MP200 MP200Nna 5 0 MP05n MP05Nna 0 0 MP00 MP00Nna SHIPPING: 2 per carton, (Wt. 4.8 lbs.) MH-T Duplex Triplex Circuit reakers reaker Type MH-T 2-Pole 0K AIC 20/240V AC Inner Poles Common Trip. Outter Poles Pole Units Ampere Rating Single Pole Quadplex Circuit reakers Ampere Rating reaker Type MH-T 2-Pole 0K AIC 20/240V AC Outter and Inner 2 Poles Common Trip Common-Trip 2-Pole 5 5 MP MP MP2255n 5 0 MP MP255n 5 40 MP MP2455n 5 50 MP MP MP22520n 20 0 MP MP2520n MP MP24520n MP25020 SHIPPING: 6 per carton, (Wt. 4.9 lbs.) Common-Trip 2-Pole Outside Common-Trip 2-Pole Inside 5 5 MP255CT2 5 0 MP250CT MP2205CT MP22050CT MP2020CT MP2025CT2 0 0 MP200CT MP2050CT MP24020CT MP2400CT MP24040CT2 SHIPPING: 6 per carton, (Wt. 4.8 lbs.) These space saver duplex breakers combine two independent /2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated. MH-T Triplex These space saver triplex breakers provide a 2-pole common trip breaker for 20/240V AC circuits and two single poles for 20V AC circuits. Triplex require two panel spaces. HACR rated. MH-T Quadplex These space saver quadplex breakers provide two sets of common trip, two-pole breakers for 20/240V AC circuits, and require two panel spaces. HACR rated. MURRAY Circuit reakers For external accessories please refer to page -20. n uilt to order. Allow 2 weeks for delivery. a Non-CTL.. For replacement use only in panels manufactured before 968. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -5

16 Circuit reakers Circuit reaker and Surge Protective Device (SPD) Features n 2 inch wide plug-on design Includes (2) Pole circuits breakers No loss of load center spaces n Easy to install and perfect for retrofit n LEDs provide protection status Circuit reaker and Surge Protective Device (SPD) enefits y installing a Siemens Circuit reaker and Surge Protective Device (SPD) in the load center of the residence, surge protection is provided for all branch circuits. MURRAY Two green LED indicator lights are provided to show that surge protection is provided for all circuits connected to the load center. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided. The circuit breaker and SPD utilize Siemens-built 50V AC, 40mm, metal oxide varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The standard interrupting rating for the circuit breakers is 0k AIC. All Type QP circuit breakers and SPD are plug-on style, with load terminals provided. The devices are rated for 20/240V AC and are calibrated for 40 degrees C maximum ambient applications. Circuit reakers reaker Type Ampere Rating Surge Type QP - Pole 20/240V AC 0K AIC (2) 5 MSA55SPD SPD (2) 20 MSA2020SPD SPD MSA55SPD MSA2020SPD Amperage of Poles Initial Clamping Level Transient Energy Rating Transient Suppression Voltage Rating Peak Current Rating (impulse) Discharge Voltage Characteristic Discharge Current Withstand Rating Circuit reaker Interrupting Rating Listings/Certifications 5 or 20 Amp (2) -Pole Circuit reakers 240 Volts 60 Joules line-to-neutral 720 Joules line-to-line 500 volts peak, line-to-neutral 000 volts peak, line-to-line 40, ,000A, 800 volts (both line-to-neutral) 0,000 amperes line-to-neutral 0,000A, 20/240V AC UL, CSA Meets UL 449 4th Edition For warranty information please refer to the surge website -6 Siemens Industry, Inc. SPEEDFAX 207 Product

17 Circuit reakers Special Application reakers HID Lighting For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. reaker Type MP-T -Pole 20V AC QP 2-Pole 20/240V AC Wiring Diagram Figure Figure Complete reaker UL Unenclosed Ampere Rating 5 MP5HIDn a 20 MP20HIDn a 0 MP0HIDn 5 MP25HIDn 20 MP220HIDn 0 MP20HIDn Molded Case Switch Molded case non-automatic switch does not provide overload protection. MP-T 2-Pole 240V AC Plug-In Figure MP260NA MP20NA Switched Neutrals For use where all conductors are required to be disconnected. Neutral pole of breaker does not connect to loadcenter bus. One side is wired to neutral and the other to the device. MG 2-Wire Common Trip 20V AC MG -Wire Common Trip 20/240V AC Figure 5 20 MP25SN MP220SN Figure 4 20 MP20SN Switched Neutrals Figure Figure 4 Wiring Diagrams MURRAY Circuit reakers n uilt to order. Allow 2 weeks for delivery. Note: All circuit breakers on this page are 0K AIC a UL Listed as SWD (Switching Duty) Rated, suitable for 20V AC Fluorescent Lighting. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -7

18 Circuit reakers Type MSQ, /4 Inch Plug-In reakers MURRAY Circuit reakers Features /4" format. HACR Rated. UL Classified for use in certain Square D b load centers. Type MSQ Circuit reakers The Type MSQ circuit breaker line is available in -pole and 2-pole common trip versions listed on this page. The circuit breakers are UL Classified and UL Listed. All MSQ breakers are supplied with load side connectors suitable for 60/75 C wire and are calibrated for 40 C maximum ambient applications. UL Classified Murray Type MSQ circuit breakers are UL Classified for use in specific Square D b loadcenters in place of Square D b Type QO circuit breakers. A Panelboard Compatibility List packaged with each QD breaker shows which type MSQ circuit breakers are acceptable for use in Square D b load centers. The interrupting rating on these circuit breakers is 0,000A IR maximum and they are not series rated with Square D b circuit breakers or equipment. This UL Classification allows a Murray Type MSQ circuit breaker to be used in place of a Square D b Type QO circuit breaker in those load centers that are specifically shown on the Panelboard Compatibility list. For additional information, contact your local Murray sales engineer. -Pole 2-Pole Wiring Diagrams -Pole 2-Pole Continuous Current Rating 20V 20/240V Common 40 C 5 MQ5 a MQ25 20 MQ20 a MQ220 0 MQ0 MQ20 40 MQ40 MQ MQ50 MQ MQ60 MQ260 Shipping Weights of Per Shipping Poles Carton Weight (lbs.) Panelboard Compatibility List Listed Panelboards Square D b s QO2L0F/S QO2-4L70F/S QO2-4L70TS QO2-4L70R QO6-2L00F/S QO6-2L00DF/S QO6-2L00TF/S QO6-2L00DTF/S QO6-2L00R QO8-6L00F/S QO8-6L00DF/S QO8-6L00TF/S QO8-6L00DTF/S QO8-6L00R QO2M00/R QO6M00/R QO20M00/R QO24M00 QO2L00DF/S QO2L00R QO2-20M00/R QO2-20M00TF/S QO2M00/R QO6-20M00/R QO6M00/R QO20M00/R QO2L25G/R QO2-24L25G/R QO2-24L25GWGC QO6L25G QO6-24L25G/R QO2-24L25/R QO20-24L25G QO20-24L25GWGC QO20L25G QO24L25G/R QO24M25/R QO6L25/R QO6-2M25FTR QO6-24L25/R QO20L25/R QO20-24L25/R QO24L25/R QO20-0L50G QO20-0M50/R QO24L50G QO24M50 QO0L50G/R QO0M50/R QO6L50/R QO6M50/R QO6-0L50/R QO8-6M50FTR QO20-0M50/R QO20-0M50TF/S QO20-0L50 QO24L50/R QO24M50/R QO0L50/R QO0M50/R QO8-6M200FT/R QO2L200G/R QO20-40M200/R QO20-40M200TC QO24M200 QO0L200G/R QO0-40M200 QO0M200/R QO0-40L200G/R QO40M200/R QO6L200/R QO6M200/R QO8-6M200FTR QO20-40L200/R QO20-40M200TF/S QO20-40M200/R QO24L200/R QO24M200/R QO0L200/R QO0M200/R QO0-40L200/R QO0-40M200/R QO40M200/R QO40M225 QO42L225G/R a UL Listed for frequent switching applications (SWD). 20V AC Fluorescent Lighting. One or two load conductors. b Square D is a registered trademark of Schneider Electric. -8 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

19 Circuit reakers Main and ranch Circuit reakers a reaker Type MD-T c 2-Pole 20/240V AC MD-HT c 2-Pole 20/240V AC MD-MT c 2-Pole 20/240V AC Ampere Rating bd UL Interrupting Ratings (ka) 50 MPD250 MPD250R 0 75 MPD275n MPD275Rn MPD2200 MPD2200R 0 50 MPD250KH MPD250RH MPD275KHn MPD275RHn MPD2200KH MPD2200RH MPD250KM MPD250RM MPD275KMn MPD275RMn MPD2200KM MPD2200RM 65 MD-T, MD-HT, MD-MT i MD-TR, MD-HTR, MD-MTR i reaker Type M e 2-Pole 20/240V AC M2 e 2-Pole 20/240V AC reaker Type ED-A f -Pole 240V AC reaker Type MPP g 2-Pole 20/240V AC MPP-HT g 2-Pole 20/240V AC MPP-MT g 2-Pole 20/240V AC MPP-PT g 2-Pole 20/240V AC Ampere Rating 00 MK00M j MK25M j MK50M k MK75M k MK200M k MK225M k 22 Ampere Rating 25 EP EP EP EP EP225 0 Ampere Rating 25 MPP MPP MPP275n MPP MPP MPP225KH MPP250KH MPP275KHn MPP2200KH MPP2225KHn MPP225KMn MPP250KM MPP275KMn MPP2200KM MPP2225KMn MPP200KPn MPP225KPn MPP250KPn MPP275KPn MPP2200KPn MPP2225KPn 00 UL Interrupting Ratings (ka) UL Interrupting Ratings (ka) UL Interrupting Ratings (ka) M M2 Type MPP-T, MPP-HT, MPP-MT, MPP-PT Type ED-A, ED-HA MURRAY Circuit reakers n uilt to order. Allow 2 weeks for delivery. a All circuit breakers on this page are common trip. b Reverse handle, ON toward lugs. See page 2-2. c Requires 4 panel spaces, 2 adjacent, and 2 opposite. d For use as load center branch and/or replacement main for old-style load center. e Main breaker kit for Rock Solid load center f Requires 6 spaces due to cross over design. g 4-poles wide for use with 200A modular and Uni-Pak metering h For use with breaker types MD-T(R), MD-HT(R), MD-MT(R) i MD-TR required for horizontal mounting applications as shown, or for vertical applications when the lugs are on top. MD-T required for vertical mounting applications with the lugs on the bottom as shown. j MK00M for use with 00A and 25A Rock Solid load centers only. MK25M for use with 25A Rock Solid load centers only. k MK50M for use with 50A, 200A, and 225A Rock Solid load centers only. MK200M for use with 200A and 225A Rock Solid load centers only. MK225M for use with 225A Rock Solid load centers only. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -9

20 Circuit reakers Circuit reaker Accessories Circuit reaker Accessories For Use With reaker Type of Poles Standard Package MURRAY Padlocking Device For locking breaker in OFF position. Note ON position does not affect breaker fuctionally ECPLD Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Duplex P Pieces ECPLDR Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Duplex P Pieces (Red Color) ECPLD2 Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Triplex & 2P Pieces Quadplex ECPLD2R Type MP-T, MP-AT2, MP-GT, MP-ET, MH-T-Triplex & 2P Pieces Quadplex, (Red Color) ECPLD Type MP-T, MP-AT2, MP-GT, MP-ET P Piece US2:ECPLDR Type MP-T, MP-AT2, MP-GT, MP-ET (Red Color) P Piece ECQLD Type MP-T P 0 Pieces ECQLD4 Type MH-T-Duplex QT-Duplex reakers 0 Pieces ECQLN M2, MD-T n/a Piece ECQTH4 Type MP-T, L, QH Designed for () P reakers Piece Handle Tie Provide simultaneous swiching of 2 adjacent handles. ECQTH2 Type MH-T Duplex Designed for (2) QT Duplex reakers 25 Pieces ECQTH Type MP-T, L 2P 50 Pieces Mechanical Interlock ECQML2 Type MP-T, Interlock racket Designed for " reaker 0 Pieces Circuit reakers Handle locking Device For holding breaker in ON or OFF position. Not a lockout/tagout device ECQL Type MP-T P 0 Pieces ECX2M Type MH-T-Duplex /2" reakers 0 Pieces Main reaker Retainer ECMR2 Rock Solid Load Centers Piece Mounting Accessories I0204ML25CU Type MP-T, ack Mounting Plates P, 2P 0 Pieces I00ML00CU Type MP-T, ack Mounting Plates P 0 Pieces Filler Plate ECQF " Filler Plate n/a 5 Pieces uilt to order. Allow 2- weeks for delivery For a complete list of standby power mechanical interlock kits, see the Standby Generator Section XXXX For use with Murray Rock Solid Center Main reakers Not suitable for use on 5-50A, 0 AIC Type MP-T Circuit reakers MP-T Type includes MP-HT, MP-MT MP-AT2 Type includes MP-HAT2 MP-GT Type includes MP-HGT MP-ET Type includes MP-HET -20 Siemens Industry, Inc. SPEEDFAX 207 Product

21 Circuit reakers Circuit reaker Accessories Padlocking Device ECPLD ECQLD Handle Tie ECQTH2 ECPLD2 Main reaker Retainer ECQTH ECPLDR/2R/R (Single pole pictured. 2-/-pole available) ECQLD4 ECQTH4 Handle locking Device ECQL ECX2M Mechanical Interlock MURRAY Circuit reakers ECMR2 ECQML2 Siemens Industry, Inc. SPEEDFAX 207 Product -2

22 Circuit reakers Line Diagrams -Pole 2-Pole -Pole " 2 /8" /8" MURRAY Type MP-T, MP-HT, MP-MT Type MH-T Type MP-GT, MP-HGT, MP-ET, MP-HET Circuit reakers Type M Type M2 Type MD-T, MD-HT, MD-MT Type MD-TR, MD-HTR, MD-MTR Type MPP-T, MPP-HT, MPP-MT, MPP-PT a All standard circuit breakers are calibrated to 40 C maximum ambient application. -22 Siemens Industry, Inc. SPEEDFAX 207 Product

23 Circuit reakers Lug Data Circuit reaker Type Circuit reaker Ampere Rating LOAD SIDE Cables Per Connector Connector Wire Range MP-T, MP-HT, MP-MT 7 2 #8 #4 CU 0 2 #6 #4 CU (exception: & 2-pole MP-T at 55-60) MP-T & 2-Pole ONLY MH-T 5 5 MP-GT, MP-HGT, MP-ET, MP-HET LF, LHF, LE, LEH #4 #6 AWG Cu #4 #6 AWG Al #8 #6 AWG Cu #8 #4 AWG Al #8-#2/0 Cu #8-#2/0 Al #6-#4 AWG Cu-Al (# requires AWG MP-HT or MP-MT) #4 #8 AWG Cu #2 #8 AWG Al 40 #8 AWG CU-Al MP-AT2, MP-HAT, AF, AFH 5 20 #8 #6 AWG Cu #8 #4 AWG Al #4 #0 AWG Cu #2 #8 AWG Al #8 #6 AWG Cu #8 #4 AWG Al #4 #2 AWG Cu #2 #0 AWG Al MSQ #4 #8 AWG Cu Only MD-T, MD-HT, MD-MT, MD-PT, MD-TR, MD-HTR, MD-MTR, MD-PTR M #4 #2 AWG Cu #2 #0 AWG Al #0 #8 AWG Cu #0 #6 AWG Al #8 #6 AWG Cu #8 #4 AWG Al # 00kcmil Cu-Al 00 #4-/0 AWG Cu #4-/0 AWG Al #4-/0 AWG Cu #4-/0 AWG Al MURRAY Circuit reakers 25 #4 /0 AWG Cu-Al M2 50 # 00kcmil Cu-Al MPP-T, MPP-HT, MPP-MT, MPP-PT 25 MQ, MQH, MQL # 00kcmil Cu-Al 225 # 00kcmil Cu-Al # AWG Cu #2/0 AWG Al #/0 AWG Cu #/0 AWG Al #2/0 AWG Cu #4/0 AWG Al #/0 AWG Cu 250kcmil AWG Al #4/0 AWG Cu 00kcmil AWG Al #6 00kcmil Cu #4 00kcmil Al Siemens Industry, Inc. SPEEDFAX 207 Product -2

24 Combination Meter Sockets Logic New Style Combination Meter Sockets JA S E C W Main Ampere Rating MURRAY Spaces (max. No. of " breakers) L = Main Lug = Main reaker Circuits (max. No. of circuits) = Phase = Phase F/S = Flush / Surface Mounting R = Ringless (blank = ring type) J = 5th Jaw = Horn ypass E = EUSERC Approved D/C = UG Feed Only / OH/UG feed L = Lever ypass Socket T = Feed Thru Lugs W = Wide Load Center Design M = Field Addable Sub Feed Main H = Double Hub Provision Z = OH Feed, Load out ottom Only A = Aluminum Enclosure JC = Meter Main JA = Meter Load Center Combination Special Suffixes: `CS = Comb. Feed with Test lock ypass DS = UG only Feed with Test lock ypass Combination Meter Sockets -24 Siemens Industry, Inc. SPEEDFAX 207 Product

25 Combination Meter Sockets Introduction This section includes 4 product categories, which each include their own set of featured products: Meter Mains Murray Meter Mains are UL Listed and available from 00A to 400A services. These Meter Mains utilize a cost effective construction that is preferable in non-euserc areas. EUSERC Meter Mains Murray EUSERC Meter Mains are UL Listed and available from 00A to 400A services. These meter mains utilize designs that meet EUSERC requirements. Two constructions are available. Over-Under Construction These Murray Meter Mains feature a classic over-under construction. Available in 00A and 25A versions. Side-y-Side Construction These Meter Mains utilize a cost effective side-by-side construction. Meter Mains combine a socket to the left and main circuit breaker section to the right. The main breaker section includes 2 to 6 circuits. Meter Load Center Combinations Murray Meter Load Center Combinations offer several different configurations and include a meter socket section and a load center section. These Murray combos feature a cost effective construction that is preferable in non-euserc areas. Over-Under Combination Construction These Murray Meter Load Center Combinations feature a overunder configuration with a unique trough allowing service from either overhead or underground to the device. Over-Under Construction These Murray Meter Load Center Combinations feature a classic over-under construction. Side-y-Side Construction These Murray Meter Load Center Combinations have a side-byside configuration. Side-y-Side Construction These Murray Meter Mains have a side-by-side construction that is slightly larger in order to meet EUSERC requirements. Side-y-Side 400A Construction These Murray Meter Mains have side-by-side construction that meets EUSERC design, and provide 400A service. EUSERC Meter Load Center Combinations Murray Meter Load Center Combinations offer several different configurations to meet a variety of installer demands. These Murray combos feature designs that meet EUSERC requirements. EUSERC EUSERC EUSERC EUSERC Over-Under etween the Studs Construction These Combos have a full width load center section above, and a meter socket section below, in a 4." wide configuration that allows flush mounting between typical 6" on center stud construction. Surface mounting options available. Side-y-Side etween the Studs Construction These combos have a half width load center section to the right and a meter socket section to the left, in a 4.2" wide configuration that allows flush mounting between typical 6" on center stud construction. Surface mounting options available. MURRAY Combination Meter Sockets EUSERC Side-y-Side Full Load Center Construction These Murray Meter Load Center Combinations have a full width load center section to the right, and a meter socket section to the left. The overall width make this combo best suited for surface mounting. EUSERC Side-y-Side 400A Construction These Murray Meter Mains have side-by-side construction that meets EUSERC design, and provide 400A service. Available with 6 to 42 circuits. Siemens Industry, Inc. SPEEDFAX 207 Product -25

26 Meter Mains Meter Mains, 00A-400A MURRAY n UL listed n Pad locking provisions on all devices n Horn bypass and 5th jaw available as noted n Side hinged door with one screw removal where shown n Suitable for use only as service entrance equipment n Contact local utility to confirm meter socket placement prior to installation n See end of section for 5th jaw and main breaker n See Section 2, pages 2-44 thru 2-46 for wiring diagrams and knockout details. For Murray devices, replace "MM" with "JC" details if JC number is not shown. Figure JC020225RJ meter mains, side hinge door Figure 2 Figure Figure 4 Figure 5 JC0406L200RHJ 200A meter main, 6 circuits JC0404L400RLM 400A meter main, two field installed mains JC002CZ 25A meter main JC002CS meter main, OH feed only Combination Meter Sockets Amps Max. Side-y-Side Construction Meter Mains No. of Spaces Max. Circuits Cover Type Mounting Service ypass Type Dimensions a Height Width Depth Ring Surface OH JC002CZ b Ringless Surface OH/UG Horn JC020225RJ c Ring JC c Ringless Surface OH/UG JC R c Ringless Horn JC RJ c Ring JC0406L200H c Ringless Surface OH/UG JC0406L200RH c Ringless Horn JC0406L200RHJ c Ringless Surface OH/UG Lever JC0404L400RLM c Figure Amps Max. Over-Under Construction Meter Mains No. of Spaces Max. Circuits Cover Type Mounting Service ypass Type Dimensions a Height Width Depth Ring Surface OH JC002CS b Ring Surface OH JC002AR b Figure a Dimensions shown are representative of outside box length, width, & depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Dimensions are subject to change. b Not suitable for 5th jaw applications. c Closure plate included. Provisions for MP-T Main reaker. -26 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

27 Meter Load Center Combinations Over-Under Construction Meter Load Center Combinations, 50A-200A n UL listed n Overhead and underground feed applications n Underground feed accomplished by use of removable gutter trough n Load wires bottom or back exit only n 22,000 AIC rated n Pad locking provisions on all devices n Side hinge doors removable by backing out only one screw n Suitable for use only as service entrance equipment n RX type hub provision on top end wall n HC type hub provision on bottom end wall n Field addable 5th Jaw (EC5J2) n Contact local utility to confirm meter socket placement prior to installation n See end of section for 5th jaw and main breaker n See Section 2, pages 2-4 thru 2-42 for wiring diagrams and knockout details. For Murray devices, replace "MC" with "JA" details if JA number is not shown. Figure JA0606L A, main lug, 6 circuit Amps Max. Figure 2 JA040850T 50A or 200A main breaker, four " spaces, feed thru lugs Figure JA08650CT 50A or 200A main breaker, eight " spaces, feed thru lugs Over-Under Combination Construction Meter Load Center Combinations No. of Spaces Max. Circuits Cover Type Mounting Service Ringless ypass Type Figure 4 JA08620RT OH feed only, feed thru lugs, trailer panel Dimensions Height Width Depth 27.0 JA040850RT c Ring JA040850T c Ring JA08650CT c Ringless JA08650RCT c 2.0 Ringless Surface OH/UG JA0606L200R abce Ring JA0606L200 abce Ringless JA0606L200RA abcde Figure MURRAY Combination Meter Sockets Ringless JA RT c Ring JA T c Ring JA086200CT c Ringless JA086200RCT c 2.0 Amps Max. Over-Under Construction Meter Load Center Combinations No. of Spaces Max. Circuits Cover Type Mounting Service Ringless Surface OH ypass Type JA086200RT Ring JA086200T Dimensions Height Width Depth Figure a No main breaker provided. Accept MD-T or MP-T type 2 or 4-pole breakers. b Suitable for use as service entrance equipment when not more than six disconnecting means are provided and when not used as a lighting an appliance panel board. Product Category RESI c Due to wire space restrictions on the trough side, the left side of the interior is limited to a 60A max branch. d Aluminum enclosure. e Suitable for use as service entrance equipment when not more than six disconnecting means are provided and when not used as a lighting and appliance panel branch circuit panel board. Siemens Industry, Inc. SPEEDFAX 207 Product -27

28 Meter Load Center Combinations Meter Load Center Combinations, 00A-400A n UL listed n 22,000 AIC Rated n Pad locking provisions on all devices n Side hinge doors removable by backing out only one screw n Suitable for use only as service entrance equipment n Contact local utility to confirm meter socket approval prior to installation n See end of section for 5th jaw and main breaker n See Section 2, pages 2-6 thru 2-50 for wiring diagrams and knockout details. For Murray devices, replace "MC" with "JA" details if JA number is not shown. Figure JA086200TH OH/UG feed, with feed thru lugs MURRAY Figure 2 Figure Figure 4 Figure 5 JA086400RLTM factory installed 200A main and provision for 2nd 60A-200A main JA042400SDL 400A, factory installed 200A main and provision for 2nd 60A-200A main MC02000S 00A, OH feed only, 20 circuits MC S 200A, OH feed only, 40 circuits Combination Meter Sockets Side-y-Side Construction Meter Load Center Combinations Amps No. of Max. ypass Dimensions Max. Spaces Circuits Cover Type Mounting Service Type Height Width Depth Figure Ringless JA08650RTH 50 Ring JA08650TH Ringless JA086200RTH 200 Ring JA086200TH Surface OH/UG Ring JA b JA08650RLTM a Ringless Lever JA RLTM a JA086400RLTM a Side-y-Side 400A Construction Meter Load Center Combinations Amps No. of Max. ypass Dimensions Max. Spaces Circuits Cover Type Mounting Service Type Height Width Depth Figure Ring Surface UG Lever JA042400SDL Over-Under Construction Meter Load Center Combinations Amps Max No. of Spaces No. of Circuits Ring Ring Cover Type Mounting Service Flush ypass Type Old New JA02000F MC02000F Surface OH none JA02000S MC02000S Flush MC02000FZ Surface MC02000SZ Dimensions H W D Flush JA F MC F 5. Surface JA S MC S 4.4 OH none Flush MC FZ 5. Surface MC SZ 4.4 Figure 5 a Feed thru lugs included. b Side by side design for OH/UG applications. c Over/under design for OH applications. Semi-Flush mounting only. Z=Solid horizontal barrier. Load wires exit back or bottom only. Dimensional and other technical data is applicable for "New s" ONLY. UL Listed for Siemens and Murray breakers. Old s JA02000SP and JA SP are obsolete with no replacement. -28 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

29 EUSERC Meter Mains EUSERC EUSERC EUSERC Side-y-Side Construction Meter Mains, 25A-400A n UL listed n For overhead and underground feed applications n Designed to meet EUSERC standards n 22,000 AIC Rated n Pad locking provisions on all devices n Surface and semi-flush units available - semi flush rails are depth adjustable for 2x6 studs n Side hinge door removable by backing out only one screw n Load wiring may exit top or bottom n Suitable for use only as service entrance equipment n RX type hub provision on top endwall, HC type hub provision on bottom endwall n 5th jaw accessory available (EMC5J) n Ring type meter covers n Contact local utility to confirm meter socket approval prior to installation n See end of section for 5th jaw and main breaker n See Section 2, pages 2-6 thru 2-50 for wiring diagrams and knockout details. For Murray devices, replace "MM" with "JC" details if JC number is not shown. Side-y-Side Construction Meter Mains Side-y-Side 400A Construction Meter Mains Figure MM020200ESC Amps No. of Max. Dimensions a Max. Spaces Circuits Mounting Service Height Width Depth Surface OH/UG JC0404L400SC d Flush UG JC0404L400FD d Surface OH/UG JC0404L400SCS cd Flush UG JC0404L400FDS cd Figure 2 JC0404L400SC 400A meter main Amps No. of No. of Cover Old New Deminsions Max Spaces Circuits Type Mounting Service ypass Type H W D 25 Flush JC0406L25FEC MM0202L25EFC 2 2 Ring OH/UG none Surface JC0406L25SEC MM0202L25ESC 200 Flush MM0202L200EFC Ring OH/UG none Surface JC0406L200FEC MM0202L200ESC 5 00 Surface JC0406L200SEC MM020200ESC Ring OH/UG none Surface MM ESC 28.6 Figure 2 2 Figure MURRAY Combination Meter Sockets a Dimensions shown are representative of outside box length, width, and depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Dimensions are subject to change. b Main breaker not included. c Test block bypass. d Main breaker: (2) Field QP(H) or QNR(H). No 5th Jaw available. Dimensional and other technical data is applicable for "New s" ONLY. UL Listed for Siemens and Murray breakers. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -29

30 EUSERC Meter Load Center Combos EUSERC EUSERC EUSERC EUSERC Meter Load Center Combinations, 00A-225A MURRAY n UL listed n For overhead and underground feed applications n Designed to meet EUSERC standards n 22,000 AIC Rated n Pad locking provisions on all devices n Surface and semi-flush units available - semi flush rails are depth adjustable for 2x6 studs n Side hinge door removable by backing out only one screw n Load wiring may exit top or bottom n Suitable for use only as service entrance equipment n RX type hub provision on top endwall, HC type hub provision on bottom endwall n Ring type meter covers n Contact local utility to confirm meter socket approval prior to installation n 5th jaw accessory available n See end of section for 5th jaw and main breaker n See Section 2, pages 2-6 thru 2-50 for wiring diagrams and knockout details. For Murray devices, replace "MC" with "JA" details if JA number is not shown. Fig. JA22L200SED Fig. EUSERC EUSERC Fig. 2 JA042200FED Fig. 4 EUSERC EUSERC MC22425EFC MC ESC Combination Meter Sockets Over-Under etween the Studs Construction Meter Load Center Combinations Amps Max. Side-y-Side Full Load Center Construction Meter Load Center Combinations 200 No. of Spaces Max. Circuits Mounting Service Flush Surface UG Surface Flush UG Surface Flush Surface UG Flush Dimensions a Height Width Depth Figure JA22L200FED a JA22L200SED a JA SED JA FED JA042200SED JA042200FED JA042225SED JA042225FED 0 JA040200SECW 40 Surface OH/UG JA SECW Fig. 5 JA SECW EUSERC Side-y-Side etween the Studs Construction Meter Load Center Combinations Amps Max No. of Spaces No. of Circuits Ring Ring Ring Ring Ring 8 6 Ring Cover Type Mounting Service Flush OH/UG ypass Type Old JA22400FEC New MC22400EFC Dimensions H W D none Surface JA22400SEC MC22400ESC Flush JA22425FEC MC22425EFC OH/UG none Surface JA22425SEC MC22425ESC Flush JA FEC MC EFC 7 OH/UG none Surface JA SEC MC ESC 5 Surface MC ESC 5 OH/UG none Flush MC EFC 7 Surface MC ESC 5 OH/UG none Flush MC EFC 7 Flush MC086200EFN 7 OH/UG none Surface JA086200SCTM MC086200ESN 5 Figure a Suitable for use as service entrance equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panel board. FRK - Flush rail kit. Dimensional and other technical data is applicable for "New s" ONLY. Old s JA6200FEC, JA6200SEC and JA6225FEC are obsolete with no replacement. UL Listed for Siemens and Murray breakers. -0 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

31 EUSERC Meter Load Center Combinations EUSERC EUSERC Side-y-Side Construction Meter Load Center Combinations, 400A n UL Listed n 400A Max, 20A Continuous n Meter socket options include 20A (400A max) lever bypass, non-bypass, test block bypass, and bolt on n Load center options include a meter main, 8 space panel with feed through lugs, 0 space panels n 22,000 AIC Rated n Accepts HD Type Hubs n Factory installed flush mount option n Surface mount devices accept field added flush rails n Suitable for use only as service entrance equipment n Contact local utility to confirm meter socket acceptance prior to installation n Designed to meet EUSERC n See Section 2, pages 2-6 thru 2-50 for wiring diagrams and knockout details. For Murray devices, replace "MC" with "JA" details if JA number is not shown. Figure JA086400SCS meter combo with feed thru lugs, factory installed 200A main and provision for 2nd EUSERC EUSERC Figure 2 JA042400SC 400A meter combo, factory installed 200A main and provision for 2nd Side-y-Side 400A Construction Meter Load Center Combinations Flush Mount Front View Accessories Description Flush Rail Kit for UG only devices ECFRK Flush Rail Kit for OH/UG feed devices ECFRK2 2" HD Type Hub EC /2" HD Type Hub EC56855 " HD Type Hub EC56856 /2" HD Type Hub EC " HD Type Hub EC56858 HD Closure Plate EC569S Snap on Sealing Ring SRSS Stainless Steel Screw Type Sealing Ring SRSW (2) #6-50 kcmil UK50TA () #2-600 kcmil UK600TA (2) kcmil UK000TA Amps No. of Max. Meter Dimensions Max. Spaces Circuits Mounting Service Socket Main reaker Height Width Depth Surface OH/UG JA086400SC Plug In Factory QN2200RH, Field QP(H), QNR(H) 9.7 Flush UG JA086400FD Surface OH/UG JA086400SCS Test lk Factory QN2200RH, Field QP(H), QNR(H) 9.7 Flush UG JA086400FDS Plug In JA042400SD Surface UG Test lk JA042400SDS Factory QN2200RH, Field QP(H), QNR(H) olt In JA042400SD Flush UG JA042400FD Plug In Factory QN2200RH, Field QP(H), QNR(H) 9.7 Surface OH/UG JA042400SC Flush UG JA042400FDS Test lk Factory QN2200RH, Field QP(H), QNR(H) 9.7 Surface OH/UG JA042400SCS EUSERC MURRAY Combination Meter Sockets 5th Jaw available. Use H Siemens Industry, Inc. SPEEDFAX 207 Product -

32 Combination Meter Sockets Electricenter Accessories MURRAY Combination Meter Sockets RX Type Hub HS Type Hub Interchangeable Hubs Conduit Size (Inches) Lbs. RX Type Hubs 4 EC8594 EC EC EC EC EC8600 HC Type Hubs 2 ECHC ECHC250 ECHC00 Accessories and Closure Plates Adapter Plate HD to RX Adapter Plate HC to RX Closure Plates EC9747- HCRXA ECHC000 (HC) ECHS000 (HS) ECHV000 (HV) EC8595 (RX) Miscellaneous Accessories EC5J-2 Sealing Rings SX00M SX006M Grounding ars (AI/Cu except where noted) Grounding bars are for use where grounding of electrical outlets and devices is by means of conductors. Each bar is equipped with large connectors rated for one #4-/0 or, two or three #4-0 Cu/AI and small connectors rated for one #4-6 or, two #4-2 Cu/AI. (May be restricted by wire bending space.) of Connectors Length Total Large Small ECLX068M ECLX069M 2 8 ECLX07M ECLX072M ECLX07M ECLX074M ECLX075M Description Snap-on type, aluminum Screw type, aluminum SRSTD SRSW Description Plastic Meter Opening Cover (JA, JC) ECPP Plastic Meter Cover Ringless (J) ECCP Fifth Jaw (for old style JA & JC units only) EC5J 5th Jaw for new style JA & JC devices EMC5J / EC5J2 5th Jaw for 9:00 with shield (see chart) H585-2 NEMA Stud Mechanical Lugs for J, JK and JL units a (2) #6-50 kcmil () #2-600 kcmil Al/Cu (2) # kcmil Al/Cu UK50TA UK600TA UK000TA Neutral Feeder Lugs #2-/0 #4-2/0 #-50 kcmil EMC5J ECLK ECLK2 ECLK Main reaker 5th Jaw JC0406L200H JC0406L200RH JC0406L200RHJ Provision for () MD-T, MD-HT or (2) MP-T, MP-HT EMC5J EMC5J Included Provision for JC0404L400RLM (2) MD-T(R), MD-HT(R), H585-2 MP-T, MP-HT JC020225RJ MP225KH Included JC MPD2200KH EMC5J JC R MPD2200KH EMC5J JC RJ MPD2200KH Included JA040850T ME968 EC5J2 JA040850RT ME968 EC5J2 JA08650CT ME968 EC5J2 JA08650RCT ME968 EC5J2 JA0606L200 b EC5J2 JA0606L200R b EC5J2 JA0606L200RA ME968 EC5J2 JA T ME968 EC5J2 JA RT ME968 EC5J2 JA086200CT ME968 EC5J2 JA086200RCT ME968 EC5J2 JA086200RT QN2200RH NA JA086200T QN2200RH NA JA08650RTH MPD250RH EMC5J JA08650TH MPD250RH EMC5J JA086200RTH MPD2200RH EMC5J JA086200TH MPD2200RH EMC5J JA MPD2200RH EMC5J JA08650RLTM MPD250RH EMC5J JA RLTM MPD2200RH EMC5J JA086400RLTM MPD2200RH EMC5J JA042400SDL MPD2200RH EC585 JA02000S(Z) MP200KH EC5J2 JA02000F MP200KH EC5J2 JA S(Z) EQ9685 EC5J2 JA F EQ9685 EC5J2 JA22L200FED NA EC5J2 JA22L200SED NA EC5J2 JA FED MK200M EC5J2 JA SED MK200M EC5J2 JA042200FED MK200M EC5J2 JA042200SED MK200M EC5J2 JA042225FED MK225M EC5J2 JA042225SED MK225M EC5J2 JA22400FEC MP200KH EMC5J JA22400SEC MP200KH EMC5J JA6200FEC MP200KH EMC5J JA6200SEC MP200KH EMC5J JA22425FEC MP225KH EMC5J JA22425SEC MP225KH EMC5J JA6225FEC MP225KH EMC5J JC0406L25FEC MP225KH EMC5J JC0406L25SEC MP225KH EMC5J JA FEC MEQ9985 EMC5J JA SEC MEQ9985 EMC5J JC0406L200FEC MEQ9985 EMC5J JC0406L200SEC MEQ9985 EMC5J JA086200SCTM EMC5J JA040200SECW MPD2200RH EMC5J JA SECW MPD2200RH EMC5J a Order one for each phase and neutral. b No main breaker provided. Accept MD-T or MP-T type 2 or 4-pole breakers. -2 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

33 Group Metering: NYC Gangable Metering General Information Product Descriptions Murray New York City Apartment Metering is a versatile, unassembled modular metering product comprised of separate modules that may be assembled to produce a variety of configurations. Only those standard modules shown in this publication will be sold. Installation instructions are shipped with the product. The modules are: Meter Stacks Meter Stacks are available from 2 to 5 meter positions, arranged vertically and pre-bussed on the line side. Each meter position is rated 00 amps continuous (25 amps maximum), 5 jaw, with the 5th jaw located at 9 o clock and connected to the stack neutral bus. Indoor mounting only. Line Troughs Line troughs are indoor horizontal wireways that support the meter stacks and supply unmetered line power to meter stack bus. Line trough is available from 2 to 5 stack positions and may be ganged by means of couplers to accommodate 6 or more stacks. Phase blocks and line terminals are required to terminate line conductors and to provide means to field wire each stack. Trough end walls are ordered separately. Phase locks Phase blocks are required to terminate line conductors and provide terminals for field connection to each stack bus. Phase blocks are available with, 6 or 2 take-off lugs. MURRAY Group Metering System Parameters n Mounting: Indoor only n Input: 208Y/20V AC, Phase, 4 Wire or 20/240V AC, Phase, Wire n Maximum line terminal- (2) 500 kcmil/phase n Output: 20Y/208V AC, Phase, wire or 20/240V AC, Phase, Wire 00 Amps continuous/meter position (25 amps maximum) n Meter Sockets: 5 jaw, with 5th jaw located at 9 o clock and electrically connected to neutral bus n Tenant Circuit reakers: Use Murray Type MP-T 2 pole plugon circuit breakers, (00 amps maximum) Siemens Industry, Inc. SPEEDFAX 207 Product -

34 Group Metering: NYC Gangable Metering General Information Getting Started MURRAY efore ordering components, the following should be known: n Installation instructions are shipped with the product n of meter positions n Amp rating of each meter position n Voltage and phase of incoming line n Line conductor size and quantity n Vertical and horizontal space limitations, if any Meter stacks are 0 wide and are 0 high for each meter position, or blank position. (A -high stack with no blank postions would be 0 wide and 0 high). When considering the overall height of an installation, you must add the height of the line trough (2 ) and the breaker trough (6 ) to the stack height. An installation of -high stacks would be 58 in overall height ( = 58 ). All meter stacks in the same meter bank must be the same height to allow the breaker trough to fit on top of the stacks. Line Terminal Kits Line terminals are available in kits of 4 terminals each. The terminals are tang lugs which mount on threaded studs provided on the phase blocks. Terminals are available in sizes: n () 50 kcmil n () 500 kcmil n (2) 500 kcmil maximum reaker Troughs reaker troughs are horizontal indoor wireways that contain provisions for plug-in circuit breakers used as tenant mains. The trough bolt to the top of the meter stacks. Field wiring connects each meter socket to a circuit breaker mounting block. reaker troughs are available in 2 to 5 stack postitions and can be ganged to accommodate 6 or more stacks. Trough end walls are ordered separately. Circuit reakers New York City Apartment Metering uses standard 2-pole plug-on circuit breakers, Murray Type MP-T, 00 amps maximum. Group Metering End Wall Kits These kits contain 4 end walls; 2 end walls for the line trough and 2 end walls for the breaker trough. Coupler Kits These kits each contain 2 trough coupler straps; one for the line trough and one for the breaker trough. These couplers mount using the same mounting screw holes as the end walls. Line Trough Spacer Kits These kits may be used to increase wire bend space between the first phase block and line entrance end wall, if necessary. They connect to line troughs with a standard coupling kit. Trough end walls are ordered separately. -4 Siemens Industry, Inc. SPEEDFAX 207 Product

35 Group Metering: NYC Gangable Metering Meter Stack Selection Use Selection Chart # and Specification Chart # Knowing the number of meter positions, and the height and width requirements, select quantity and catalog number of stacks from Selection Chart #. The height dimension in this chart includes line and breaker troughs. For specs, refer to Specification Chart #. Specification Chart # Meter Stacks 00V AC max., 00 Amps/Position Continuous Duty, or Phase Network Meter Positions a All stacks are 0 wide. Selection Chart # Meter ank Height and Width Meter Stack Combinations for Various Heights and Widths, by of Meter Positions No. of Meter Positions Height a (Inches) 2 20 UVS20 #6-4/0 2 0 UVS #6-4/0 0 UVS0 #6-4/0 40 UVS4 #6-4/ UVS40 #6-4/ UVS5 #6-4/ UVS50 #6-4/0 Wire Range Line Terminals 58 High 68 High 78 High Use this Quantity of: Width Use this Quantity of: Width Use this Quantity of: UVS0 UVS (Inches) UVS40 UVS4 (Inches) UVS50 UVS5 Width (Inches) Not Practicala Not Possible b Not Practical b Not Practical b MURRAY Group Metering a Use () UVS0 instead of () UVS4. b Use -high or 4-high stacks. Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -5

36 Group Metering: NYC Gangable Metering Trough & Phase lock Selection Line Troughs (Use Selection Chart #2 and Specification Chart #2) Knowing the number of meter stacks, (not meter positions!) and the height and width requirements, select quantity and catalog number of stacks from Selection Chart #2. For specs, refer to Specification Chart #2 reaker Troughs (Use Selection Chart #2 and Specification Chart #) Using the total number of meter stacks, (not meter positions!), select the quantity and catalog number of breaker troughs from Selection Chart #2 and spec from Specification Chart #. Use MP-T style breakers only. reakers not included. Phase locks (Use Selection Chart #2 and Specification Chart #4) Using the number of meter stacks and the incoming power supply, use Selection Chart #2 to determine the quantity and catalog number of phase blocks for line and neutral termination. Spec these from Specification Chart #4. MURRAY Selection Chart #2 Line Trough, reaker Trough and Phase lock Selection No. of Meter Stacks in ank Line Trough Selection Left Trough Middle Trough Right Trough reaker Trough Selection Left Trough Middle Trough Right Trough Phase lock Section Phase, 4 Wire System Phase, Wire System Line locks Neutral lock Line locks Neutral lock ULT0a UT0 () UP () UP (2) UP () UP 4 ULT40b UT40 () UP () UP6 (2) UP6 () UP6 5 ULT50 UT50 () UP6 () UP6 (2) UP6 () UP6 6 ULT0c ULT0 UT0c UT0 () UP6 () UP6 (2) UP6 () UP6 7 ULT40c ULT0 UT40c UT0 () UP6 () UP2 (2) UP2 () UP2 8 ULT40c ULT40 UT40c UT40 () UP6 () UP2 (2) UP2 () UP2 9 ULT50c ULT40 UT50c UT40 () UP6 () UP2 (2) UP2 () UP2 0 ULT50c ULT50 UT50c UT50 () UP2 () UP2 (2) UP2 () UP2 ULT40d ULT40 ULT0 UT40d UT40 UT0 () UP2 () UP2 (2) UP2 () UP2 2 ULT40d ULT40 ULT40 UT40d UT40 UT40 () UP2 () UP2 (2) UP2 () UP2 a Spacer ULT0SP is required if line conductors exceed #6 AWG. b Spacer ULT0SP is required if line conductors exceed #50 kcmil. c Requires () UCP26 Coupler Kit. Kit provides coupling straps for both line and breaker troughs. d Requires (2) UCP26 Coupler Kits. Kit provides coupling straps for both line and breaker troughs. Specification Chart #2 Line Troughs 240V AC max. Phase or Phase Stack Positions Widtha (Inches) 2 20 ULT20 b 0 ULT ULT ULT50 Specification Chart # reaker Troughs a Stack Positions Widtha (Inches) 2 20 UT20 0 UT UT UT50 Group Metering a Line troughs are 2 high. b Will not accommodate Phase locks. Specification Chart #4 Phase locks 240V AC max. Phase or Phase of Take-off Lugs Wire Range Linea Load UP /8 x 6 Stud #6 - #4/0 6 UP6 /8 x 6 Stud #6 - #4/0 2 UP2 /8 x 6 Stud #6 - #4/0 a Use Murray Type MP-T circuit breakers. reakers not included. b Height is 6. a Requires separate line lug kit. -6 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category RESI

37 Group Metering: NYC Gangable Metering Terminals & Accessories Line Terminals (Use Specification Chart #5) Knowing the size and quantity per phase of the line conductors, select and spec these from Specification Chart #5. Line terminals come in kits of four terminal each. One kit will supply line terminals for three phase legs and neutral. End Walls (Use Specification Chart #6) NOTE: Each installation MUST have an end wall kit! The kit provides end walls for each end of the line and breaker troughs. (Four end walls). Use Specification Chart #6. Specification Chart #5 Line Terminals Wire Range () #6-50 kcmil ULK50 () #4-500 kcmil or ULK500 (2) #/0-250 kcmil (2) #2-600 kcmil ULK2500 Specification Chart #6 End Wall and Coupling Kits Item End Wall Kit Contains 4 end walls; 2 for line trough and 2 for breaker trough. Coupling Kit Contains 2 coupling straps; for line trough and for breaker trough. Specification Chart #7 Accessories Item Spacer 0 spacer for use with line trough to provide wire bend space where required Meter Cover lank Position Cover Plastic Meter Cover (Ring Type) reaker Filler Plate Coupling Kits (Use Selection Chart #2 and Specification Chart #6) When more than one line trough is needed to support the number of meter stacks on a job, or when a line trough spacer is required, coupling straps are required to connect the troughs. Use Selection Chart #2 footnotes and 4 to determine quantity of coupling kits required. Each kit provides one strap for line trough and one strap for breaker trough. Spec from Specification Chart #6. UEW26 UCP26 ULT0SP UMCVR UMCVR SX087M LX00FP Line Trough Spacer Kits (Use Selection Chart #2 and Specification Chart #6) In some applications, the first phase block may be too close to the end wall of the line trough to provide proper wire bend space for the line conductors being used. Selection Chart #2 footnotes and 2 will show when spacer kits are required. Tenant Circuit reakers Each meter position in use requires a tenant circuit breaker. Use standard Murray Type MP-T circuit breakers from the Murray. MURRAY Group Metering Product Category RESI Siemens Industry, Inc. SPEEDFAX 207 Product -7

38 Safety Switches General Description GHN424NW HHN426N HUN6AW MURRAY Safety Switches Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the development and manufacturing processes, switches have performed successfully in tests witnessed by Underwriters Laboratories. These tests include those for general purpose safety switches and those designed for more specialized purposes where applicable. Handle Lock-Off Heavy duty, H series safety switches have a provision to lock the handle in the OFF position with a maximum of three padlocks. Doors may be locked closed with a padlock. General duty, G series switches may be locked in the OFF position with one padlock. There is also a padlock feature for locking the door. General and Heavy Duty Switches Feature a Time Proven Design A fast, long lasting switch design with a clean, continuous contact. That s the switching system that gives you on-going reliability. The concept is simple: split the arc to shorten the break distance. Uncomplicated mechanics and common sense design assure reliable performance time after time. All switches through 200A feature visible blade contruction. Load reak Ratings All Murray safety switches are UL Listed for load break applications. Included in this process is a series of repeated make and break tests of the switch contacts while carrying the full rated nameplate current and rated voltage. Horsepower Ratings Where permitted, all Murray safety switches are UL horsepower Listed. The switch ratings are determined by tests that have been performed successfully in the UL overload test series, including repeated make and break tests of the stalled motor current of the motor for which it is being rated. Some switches have two or more ratings for a particular voltage and current, and additional ratings if designed for multi-pole applications. Depending on the switch and its application, various ratings may be assigned. All switches list the ratings on the inside of the cover or the door. The ampere rating and maximum AC voltage rating are always shown on the nameplate on the front of the switch. Fault Current Performance Murray Heavy Duty safety switches have successfully passed UL high level fault current tests. This means the risk of mechanical and thermal damage due to high level short circuit currents is minimized due to the reliable switch design. Suitability tests for service with Class H, R, J, L, and T fuses have been conducted on heavy duty safety switches. Representative switches, with test fuses connected in series with each switch, were subjected to let-throughs in excess of the capacities of the largest fuses acceptable by the switches. To pass the test, the switch must remain operable after being closed into a high amp available short circuit current. The test fuse is sized so that higher levels of let-through current and energy will be reached than would ever occur during normal usage in the field. Murray General Duty safety switches have been tested to allow installation on circuits capable of delivering 00,000 AIC of fault current at 240V AC max. with Class R fuses and also with both Class J and T fuses in A ratings. Fuse Interchangeability General Duty Switches, Prefix G,* will accept the following UL class fuses: Class H Class K Class R Requires class R fuse kit to maintain UL listing. Class J A field convertible. Class T with proper adapter kit (00 600A). *Except 0 amp plug style switches. Heavy Duty Switches, Prefix H, will accept the following UL class fuses: Class H Class K Class R Requires class R fuse kit to maintain UL listing. Class J All 0 200A, 600V and A, 240V switches field convertible. Class L 800 and 200A switches only. Class T A switches with proper adapter kit. Gutter Space G and H series safety switch gutter dimensions conform to 2008 NEC Article #2.6(A). Top and bottom gutters conform to Table #2.6(). -8 Siemens Industry, Inc. SPEEDFAX 207 Product

39 Safety Switches Technical Information General Duty Switches; Prefix G General duty switches are available in indoor TYPE and outdoor TYPE R enclosures. Enclosures can be locked closed and operating handles can be locked off. Series G switches have a quick-make, quick-break mechanism. Fusible switches are available in pole S/N, 2 pole S/N and pole S/N configurations. Non-fusible switches are available in pole configurations. General duty switches are limited to 240V AC, 200 Amps max. rating. All 0 Amp compact fusible and non-fusible G prefix switches are rated 0,000 Amp maximum withstand. All Amp GF and GU prefix switches are suitable for use on systems capable of delivering not more than 00,000 RMS symmetrical Amps of fault current with Class R fuses and the appropriate adapter kit installed. These Amp G prefix switches may also be used on systems capable of delivering not more than 00,000 RMS symmetrical Amps of fault current with T fuses and the appropriate adapter kit installed. In addition, general duty switches may also be used with J fuses on systems not capable of delivering more than 00,000 RMS symmetrical amperes of fault current. General duty switches are UL Listed for use as service equipment and are horsepower rated for use with motor loads. General duty enclosed switches are used for light duty applications where loading and switching operations are not excessive. Heavy Duty Switches, Single Throw; Prefix H Heavy duty switches are available in indoor TYPE, outdoor TYPE R, Watertight Type 4/4X, and industrial TYPE 2 enclosures. Dual cover interlocks are provided, such that the door cannot be opened with the switch ON and the switch cannot be turned ON with the door open. A defeat mechanism allows servicing by authorized personnel. Handles may be locked OFF with up to padlocks, and doors may be padlocked closed. Mechanism is TEASE-PROOF quick-make, quick-break. Fusible switches are available in 2 pole S/N, pole and pole S/N. Non-fusible switches are available in pole. Suitable for use on systems capable of delivering not more than 200,000 RMS symmetrical amperes of fault current when Class J or R fuses are installed except the 800 and 200A switches, which are suitable for use on circuits capable of delivering not more than 200,000 RMS symmetrical amperes of fault current when Class L fuses are installed A switches with Class T fuses and field adapter kit 200,000 RMS symmetrical rated. Heavy duty switches are dual horsepower rated and are listed by UL for use as service entrance equipment. Heavy duty switches are intended for applications where rugged construction, reliable performance, continuity of service and ease of maintenance are required. Protector-Lock Switches; Prefix H The Murray Protector-Lock switch is designed to eliminate shock hazard due to disconnecting heavy duty portable electrical equipment under load. When the switch is in the ON position, the safety bar blocks the self-contained receptacle and prevents insertion or removal of the plug. When the switch is OFF, the bar retracts, allowing insertion or removal of the plug. Protector-Lock switches consist of a heavy duty, 0 or 60 Amp, 600V AC, pole fusible or non-fusible enclosed switch, and either Crouse-Hinds or Arrow Hart Industrial receptacles. Applications include industrial plants where portable conveyors and welders are used, and truck terminals where on-board refrigeration units require stand-by power. Double Throw Switches; Prefix HD Double throw switches are available in TYPE and TYPE R enclosures. Covers are dual interlocked with the operating mechanism such that the cover cannot be opened when the switch is in either ON position, and the switch handle cannot be moved to either ON position if the cover is open. Handle may be padlocked in the OFF position. Switching action is quick-make, quick-break in both ON positions. They are available in Amp ratings, 240V AC, fusible and non-fusible, two and three pole. Double throw switches are usually applied as transfer switches to switch a load from one power source to another, but can be field converted to switch one power source between two loads. Switching mechanism is located on line side of fuses allowing for a safer fuse replacement. All are suitable for use as service equipment. Industry and Government Specifications Murray enclosed switches meet or exceed the latest revision of the following specifications: Industry NEMA Standard #KS--200 UL-Standard #98 U.S. Government HD single throw, prefix H : Standard #WS-865c type HD HD double throw, prefix HD : Standard #WS865c type NDD GD Amp, prefix G : Standard #WS 865c type ND ; except where interlock is required. GD 0 Amp, prefix G : Standard #WS-865c type ND ; except where interlock is required. Arrow Hart and Crouse-Hinds are registered trademarks of Cooper Industries, Inc. Protector-Lock is a registered trademark of Siemens Energy & Automation Inc. MURRAY Safety Switches Product Category GDSM and HDSM Siemens Industry, Inc. SPEEDFAX 207 Product -9

40 Safety Switches General Duty Compact 0,000 Amp Withstand Plug Fuse Type & Type R GU22 GP2N MURRAY General Duty Compact Safety Switches Symbol Fuse Type Indoor TYPE Std. Pkg. Approx. Wgt. Lbs. Outdoor TYPE R Std. Pkg. Approx. Wgt. Lbs. Hub Horsepower Rating Single Phase Three Phase 20V AC 240V AC 240V AC Std Max a Std Max a Std Max a 0 AMP FUSILE POLE 2 WIRE S/N 20V AC (INSULATED GROUNDALE NEUTRAL) Fig- Plug GP2N AMP FUSILE 2 POLE WIRE S/N 240V AC (INSULATED GROUNDALE NEUTRAL) Fig-2 Plug GP2N ECHA Fig- None GU GU22AW ECHA 2 60 AMP NON-FUSILE 2 POLE 240V AC SPECIAL APPLICATION SWITCH Fig-4 None GU222AW b 0 Accessories and Lug Data See pages -47 and -48. Dimensions See pages -49, -50 and -5. Knockout Drawings See page -52. Figure Figure 2 Figure Figure 4 Hubs Conduit Size (Inches) 4 ECHA075.0 ECHA ECHA25.0 Approx. Wgt. Lbs. (Std. Pkg. ) General Duty Stand-by Power Panel This unique device provides an economical means to transfer from normal to an alternate source of power. It contains two 00A, 2-pole circuit breakers interlocked in a double throw configuration and supplies both overload and short circuit protection (0,000 AIC max.). The external handle is padlockable in the OFF position. Safety Switches Outdoor TYPE Std. Pkg. Approx. Wgt. Lbs. 00A 2 POLE WIRE S/N 20/240V AC OUTDOOR TYPE R d Hub DULNW c 9.00 ECHS N a Starting current of motors above standard horsepower rating may require use of time delay fuses. b ottom cable entry & exit only. c Suitable for service entrance application. Neutral factory installed. UL008 listed as a non-automatic transfer switch under file #E500. Suitable for use as Transfer Equipment on optional stand-by systems as defined by Article 702 of the NEC. d Wire ranges (75 C Cu/Al) Line, load & neutral () #4- Service ground () #4-4 e Discount Schedule HDSM. -40 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category GDSM

41 Safety Switches General Duty Amp, 0,000 & 00,000 Amp Withstand Cartridge Fuse Type & Type R GUN22 GHN2N GHN42NW Switch Selection with Class H Fuse Holders Amps (Convertible to Class R ) a Symbol Amps Indoor TYPE Accessories and Lug Data See pages -47 and -48. Dimensions See pages -49, -50 and -5. Knockout Drawings See page -52 and -5. Std. Pkg. Approx. Wgt. Lbs. Outdoor TYPE R Std. Pkg. Figure Figure 2 Figure Approx. Wgt. Lbs. FUSILE 2 POLE WIRE S/N 240V AC (INSULATED GROUNDALE NEUTRAL) c de Hub Horsepower Rating Single Phase Three Phase 240V AC 240V AC 250V DC Std Max Std Max Std Fig- 0 GHN2N c GHN2NW c ECHA GHN22N c 4.00 GHN22NW c 4.00 ECHS GHN2N c 2.00 GHN2NW c ECHS GHN24N c GHN24NW c ECHS FUSILE POLE 4 WIRE S/N 240V AC (INSULATED GROUNDALE NEUTRAL) e Fig-2 0 GHN42N GHN42NW ECHA GHN422N 5.00 GHN422NW 5.00 ECHS GHN42N GHN42NW ECHS GHN424N GHN424NW ECHS NON-FUSILE POLE 240V AC (SEE PREVIOUS PAGE FOR 2 POLE, 0 AMPS; USE POLE FOR 2 POLE APPLICATION FOR AMPS) Fig- 0 GUN GUN2AW ECHA GUN GUN22AW.00 ECHS GUN GUN2AW ECHS GUN GUN24AW ECHS MURRAY Safety Switches a G Series switches are UL Listed for use on circuits capable of delivering up to 00,000 Amps RMS symmetrical fault currents, provided Class R or T fuses and appropriate rejection or adapter kits are installed. T-fuses can only be used on Amp A switches can also be used with Class J fuses. b Starting current of motors above standard horsepower rating may require use of time delay fuses. c These switches are UL Listed for application on grounded systems. dsuitable for -pole motor loads. ehas service entrance label, neutral factory installed. Product Category HDSM Siemens Industry, Inc. SPEEDFAX 207 Product -4

42 Safety Switches Heavy Duty 240V AC, 0,000 & 200,000 Amp Withstand Cartridge Fuse Type & Type R HHN422N HHN2NW HHN42NW Safety Switches MURRAY Switch Selection with Class H Fuse Holders (Convertible to Class J, R or T ) a Symbol Amps Indoor TYPE Std. Pkg. Approx. Wgt. Lbs. Outdoor TYPE R Std. Pkg. Approx. Wgt. Lbs. FUSILE 2 POLE WIRE S/N 240V AC (INSULATED GROUNDALE NEUTRAL) de h Hub Horsepower Rating Single Phase Three Phase 240V AC 240V AC 250V DC Std Max Std Max Std Fig- 0 HHN2N 2.00 ECHS HHN22NW 9.00 ECHS HHN2NW ECHS HHN24N ECHS HLN27N bf HLN28N bf FUSILE POLE 4 WIRE S/N 240V AC (INSULATED GROUNDALE NEUTRAL) e h Fig-2 0 HHN42N 4.00 HHN42NW 5.00 ECHS HHN422N 9.00 HHN422NW ECHS HHN42NW ECHS HHN424N ECHS HLN427N bf HLN427NW bf 8.00 ECHV g HLN428N bf HLN428NW bf ECHV g Accessories and Lug Data See pages -47 and -48. Dimensions See pages -50 and -5. Knockout Drawings See pages -52 and -5. Figure Figure 2 a Switches through 200 Amps listed by Underwriters Laboratories for use on circuits delivering up to 200,000 Amps RMS symmetrical fault current, provided class R, J, L, or T fuses are used. Rejection kits must be installed for R fuse application. T fuse adapter kit required for T fuse application. See Accessory Page. J fuses can only be used on A ratings. T fuses can only be used on A ratings. b Factory set for use with class L fuses. c Starting current of motors above standard horsepower rating may require use of time delay fuses. dsuitable for -pole motor loads. e Suitable for service entrance application. Neutral factory-installed. f Supplied without knockouts. g 800A and larger Type R switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. h Also rated 250V DC -42 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category HDSM

43 Safety Switches Heavy Duty 600v AC, 0,000 & 200,000 Amp Withstand Cartridge Fuse Type & Type R HHN6AW HHN64 Plus Neutral HN64M Switch Selection with Class H Fuse Holders (Convertible to Class J, R or T ) a Indoor TYPE Outdoor TYPE R Symbol Amps Accessories and Lug Data See pages -47 and -48. Dimensions See pages -50 and -5. Knockout Drawings See pages -52 and -5. Approx. Wgt. Lbs. (Std. Pkg. ) a Switches through 200 Amps listed by Underwriters Laboratories for use on circuits delivering up to 200,000 Amps RMS symmetrical fault current, provided class R, J, L, or T fuses are used. Rejection kits must be installed for R fuse applications. b Class L fuse provision. Single fuse per pole. Supplied without knockouts. c Order pole switch from chart above, and neutral from accessory page. Approx. Wgt. Lbs. (Std. Pkg. ) Hub Figure Figure 2 Figure d Starting current of motors above standard horsepower rating may require use of time delay fuses. e For service equipment or applications requiring a solid neutral, order neutral kit as an accessory, page -8. f A switches are also rated 600V DC when 2 poles are connected in series. g 800A and larger Type R switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. Horsepower Rating 480V AC Ø 480V AC Ø 600V AC Ø 600V AC Ø Std Max Std Max Std Max Std Max FUSILE POLE 600V AC (NO NEUTRAL) ef Fig- 0 HHN6AW 5.00 ECHS HHN HHN62AW ECHS HHN HHN6AW ECHS HHN HHN64AW ECHS HLN67 b HLN67AW b ECHV g HLN68 b 8.00 HLN68AW b ECHV g FUSILE POLE 4 WIRE S/N 480Y / 277V AC (INSULATED GROUNDALE NEUTRAL) f Fig-2 0 c 60 c NON-FUSILE POLE 600V AC (USE FOR 2 POLE) efi Fig- 0 HUN HUN6AW.00 ECHS HUN HUN62AW 9.00 ECHS HUN HUN6AW ECHS HUN HUN64AW ECHS V DC 600V DC i Non-fusible switches also have the following max. HP ratings. Amps Ø 240V AC Ø 240V AC MURRAY Safety Switches Product Category HDSM Siemens Industry, Inc. SPEEDFAX 207 Product -4

44 Safety Switches Heavy Duty 600V AC, 0,000 & 200,000 Amp Withstand Cartridge Fuse Industrial Type 2 & 4X MURRAY HUN6AJ Accessories and Lug Data See pages -47 and -48. Dimensions See pages -50 and -5. Switch Selection With Class H Fuse Holders (Convertible To Class J, R or T ) a Industrial Type 2 Symbol Amps Approx. Wgt. Lbs. (Std. Pkg. ) FUSILE POLE 600V AC (NO NEUTRAL) cf Horsepower Rating 480V AC Ø 600V AC Ø Std Max Std Max 250V DC 600V DC Fig- 0 HHN6AJ HHN62AJ NON-FUSILE POLE 600V AC (USE FOR 2 POLE) cef Fig-2 0 HUN6AJ Symbol Amps Type 4X Stainless Steel Approx. Wgt. Lbs. (Std. Pkg. ) Horsepower Rating 480V AC Ø 600V AC Ø Std Max Std Max NON-FUSILE POLE 600V AC (NO NEUTRAL) cdef 250V DC 600V DC Fig-2 60 HUN62AS HUN64AS Figure Figure 2 Safety Switches a Switches through 200 Amps listed by Underwriters Laboratories for use on circuits delivering up to 200,000 Amps RMS symmetrical fault current, provided class J, R or T fuses are used. Rejection kits must be installed for R fuse applications. b Starting current of motors above standard horsepower rating may require use of time delay fuses. c For service equipment or applications requiring a solid neutral, order neutral kit as an accessory, page -8. d Use pole switch for 2 pole applications. e 240V Ø HP ratings are as follows: HP Max. HP Max. Amps HP Std Fusible Non-Fusible f A switches are also rated 600V DC when 2 poles are connected in series. -44 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category HDSM

45 Safety Switches VII Type Double Throw Switches Type & Type R Double Throw Switches a Symbol Amps Indoor TYPE Approx. Wgt. Lbs. Outdoor TYPE R Approx. Wgt. Lbs. Hub Horsepower Rating Ø Std Ø Max Ø Std Ø Max 250V DC NON-FUSILE 2 POLE 240V AC Fig- 00 HDUN HDUN HDUN224AW ECHS 5 40 FUSILE POLE 240V AC Fig- 0 HDHN HDHN2AW 9.00 ECHS Neutral Kits For use with Double Throw Switches Switch Amps HN26M Figure Figure Fuse Capabilities of Fusible Switches Amp Rating Fuse Type H R T J 0 & 60 A Std Yes (kit) No No 00 & 200A Std Yes (kit) Yes (kit) Yes 5 Double Throw Switches Lug Data Switch Amp Range of Cables Per Terminal Cu and/or Al Wire Range 0 pc. Cu or Al #4 to #6 60 pc. Cu or Al #4 to #2 00 pc. Cu or Al #4 to #/0 200 pc. Cu or Al #6 to 250 kcmil MURRAY Safety Switches Rated 0,000 AIC with Class H or 200,000 AIC when used with or protected by Class R, J or T fuses. Fuse rating must not exceed switch ampere rating A and larger double throw switches do not have a hub provision. Typical wiring diagrams for amp switches are shown. 4 HP ratings at 480V. 5 Move load side base. 6 General Duty Double Throw Switches are also available in 00 and 200A ratings. Contact sales for additional info. 7 A 00A 2P General Duty Stand-by Power Panel is also available on page -40. Product Category HDSM Siemens Industry, Inc. SPEEDFAX 207 Product -45

46 Safety Switches Protector-Lock Switches Protector-Lock Switches With Crouse-Hinds Receptacles Industrial Type 2 Symbol Switch Amps Recept Amps Approx. Wgt. Lbs. (Std. Pkg. ) Use Plug # b NON-FUSILE, POLE 600V AC SWITCH (STYLE 2 RECEPTACLE, 4 WIRE, ONE WIRE GROUNDED) Fig HUN62CJ APJ6485 MURRAY Accessories and Lug Data See pages -47 and -48. Dimensions See pages -50 and -5. Figure 2 Safety Switches anot UL listed. bsee Accessories page -48 for plug selection. Arrow Hart, Power Lock, & Crouse-Hinds are registered trademarks of Cooper Industries, Inc. Protector-Lock is a registered trademark of Siemens Energy & Automation, Inc. -46 Siemens Industry, Inc. SPEEDFAX 207 Product Product Category HDSM

47 Safety Switches Accessories HN62M HT6M HR62M Neutral Kits a Standard Neutral Kits can be field installed in General and Heavy Duty Switches. Switch Ampere Rating Kit 0 GD W4090M 0 HD, 60 GD HN62M 60, 00 HD, 00 GD HN62M 200 HN64M HA624M Class T Fuse Adapter Kits c All 200A General Duty and A Heavy Duty Switches are field convertible to accept Class T fuses. HT2M d HT6M HT24M d HT64M HX27TF HX67TF HX28TF Description 00A, 240V Kit 00A, 600V Kit 200A, 240V Kit 200A, 600V Kit 800A, 240V Kit 800A, 600V Kit 200A, 240V Kit Equipment Ground Kits Equipment Ground Lug Kits are available for all General Duty, Heavy Duty and Double Throw Switches. They are field installable in Type and Type R Switches and are factory installed as standard in Type 4/4X and Type 2 Switches. Switch Ampere Rating of Terminals Wire Range Per Terminal (Cu/Al) 0A GD GSGK60M 2 #4-8 AWG GD HG624M 2 #4-4 AWG HD HG624M 2 #4-4 AWG HG678M 8 #6 AWG-250 Kcmil HA2624M Class R Fuse Clip Kits b GSRK2M HR2M HR62M HR62M HR6M HR64M Description 0A, 240V Kit (GD only) 0A, 240V Kit (HD only) 0A, 600V Kit/60A, 240V Kit 60A, 600V Kit 00A Kit 200A Kit Class J Fuse All A General Duty and 600V 0-200A Heavy Duty Switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. MURRAY Safety Switches a All neutral kits are provided with a grounding lug and also contain a bonding provision. b One kit per switch required for General and Heavy Duty switches. Two kits required per Doubble Throw Switch. c() kit per pole required. d 00 and 200A Double Throw switches are also convertible from H to T fuses by using (6) kits per switch. Product Category HDSM Siemens Industry, Inc. SPEEDFAX 207 Product -47

22,000 A IR. 65,000 A IR Catalog Number. Catalog Number. MPA115AFCHn a MPA120AFCHn a MPA115AFCHH MPA120AFCHH. MP215AFCHn a MP220AFCHn a

22,000 A IR. 65,000 A IR Catalog Number. Catalog Number. MPA115AFCHn a MPA120AFCHn a MPA115AFCHH MPA120AFCHH. MP215AFCHn a MP220AFCHn a Arc-Fault Circuit Interrupters (AFCI) Revised 06//4 Combination Type AFCI b AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect.

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series

More information

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure.

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI)

More information

Ultimate Load Centers

Ultimate Load Centers Ultimate Load Centers General Information FEATURES UL Listed. INSTA-WIRE TM neutrals, grounds, and circuit breakers provide quick conductor installation. Visible neutrals aid in conductor installation.

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Technical Data and Specifications. Table 12-153. UL 489 Interrupting Capacity Ratings. Number of Poles 2, 3 2, 3, 4 2, 3, 4 2, 3, 4.

Technical Data and Specifications. Table 12-153. UL 489 Interrupting Capacity Ratings. Number of Poles 2, 3 2, 3, 4 2, 3, 4 2, 3, 4. May 8 Typical Circuit Product Description All Eaton s Cutler-Hammer Circuit s are HACR rated. circuit breakers are available as individual components (Frame, Trip Unit, Terminals), or factory assembled

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Load Centers. GE load centers deliver the highest quality and convenience.

Load Centers. GE load centers deliver the highest quality and convenience. GE Load Centers GE load centers deliver the highest quality and convenience. Load Centers GE load centers lower your costs by making installation faster and easier and by increasing application flexibility.

More information

2. Wiring Diagrams: Power, signal, and control wiring. 3. Field quality-control test reports. 4. Operation and maintenance data.

2. Wiring Diagrams: Power, signal, and control wiring. 3. Field quality-control test reports. 4. Operation and maintenance data. SECTION 262416 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes all panelboards. 1.2 SUBMITTALS A. Product Data: For each type of panelboard, overcurrent protective device, accessory, and component

More information

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution Table of Contents Introduction...2 Residential Power Distribution...4 Load Centers...6 Load Center Construction...8 Residential Circuit Breakers... 16 Ground Fault Protection...23 Arc Fault Protection...25

More information

PHYSICAL FACILITIES. 2015 Consultant s Handbook Division 26 ELECTRICAL 2413 SWITCHBOARDS. Page 1 of 11

PHYSICAL FACILITIES. 2015 Consultant s Handbook Division 26 ELECTRICAL 2413 SWITCHBOARDS. Page 1 of 11 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

60120 Circuit Breaker

60120 Circuit Breaker 6020 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Ordering and Shipping Information Features and Specifications

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22]

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22] [previous page #: 2-18; 2-22] Combination Logic Combination Sockets MC 30 40 B 1 200 S E C W 2 ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L =

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W Centers Combination Catalog Number Logic Combination Sockets MC 30 40 B 1 00 S E C W ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L = Lug MB or

More information

C. ANSI C Electrical Analog Indicating Instruments. E. ANSI C Guide for Transformer through Fault Duration.

C. ANSI C Electrical Analog Indicating Instruments. E. ANSI C Guide for Transformer through Fault Duration. SECTION 264260 - DISTRIBUTION SWITCHBOARDS PART 1 GENERAL 1.01 SECTION INCLUDES A. Main switchboard. 1.03 RELATED SECTIONS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

A. Section includes switchboards, distribution panelboards, and lighting and appliance branch circuit panelboards.

A. Section includes switchboards, distribution panelboards, and lighting and appliance branch circuit panelboards. 26 24 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes switchboards, distribution panelboards, and lighting and appliance branch circuit panelboards. 1.02 PERFORMANCE REQUIREMENTS A. Seismic performance:

More information

Types Of Load Centers

Types Of Load Centers Types Of Load Centers Main Breaker There are two types of load centers, main breaker and main lug only. Main breaker load centers are suitable for use in service entrance applications. The incoming supply

More information

ASCO 920 Product Specifications

ASCO 920 Product Specifications ASCO is the global leader in power switching and controls ASCO 90 Product Specifications Only (Panelboard Mounting),,. Suitable insulation must be behind switch unit.. Suitable for bus bar mounting. Lugs

More information

ASCO SERIES 165 Residential / Light Commercial Automatic Transfer Switches.

ASCO SERIES 165 Residential / Light Commercial Automatic Transfer Switches. ASCO SERIES 165 Residential / Light Commercial Automatic Transfer Switches. Time Delays 3-second time delay to override momentary utility source. 15-second transfer to emergency time delay to allow engine

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Panelboard Mounting with INSTA-WIRE 1-Pole Bolt-On (120V AC) e Bolt-On (Common-Trip 120/240V AC) f 10 B210 15 B215 B215H B215HH 20 B220 B220H B220HH 25 B225 B225Hn B225HHn 30 B230 B230H B230HH 35 B235

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

SECTION 2. TECHNICAL REQUIREMENTS FOR SERVICE UP TO AND INCLUDING 5 kv

SECTION 2. TECHNICAL REQUIREMENTS FOR SERVICE UP TO AND INCLUDING 5 kv SECTION 2 TECHNICAL REQUIREMENTS FOR SERVICE UP TO AND INCLUDING 5 kv Section 2 201 TABLE OF CONTENTS 2.1 RESIDENTIAL...207 2.1.1 Applicability...207 2.1.2 General Requirements...207 2.1.3 Point of Delivery...208

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

Super Blue Pennant Switchboards Warehouse Stock

Super Blue Pennant Switchboards Warehouse Stock Warehouse Stock Features The Super Blue Pennant service entrance switchboard is designed to meet the needs of main over current protection with distribution devices for medium duty service applications.

More information

65,000 A IR Catalog Number QA115AFCHH QA120AFCHH. 22,000 A IR Catalog Number. QA115AFHn a QA120AFHn a. Q215AFCHn a Q220AFCHn a QA115AFHH QA120AFHH

65,000 A IR Catalog Number QA115AFCHH QA120AFCHH. 22,000 A IR Catalog Number. QA115AFHn a QA120AFHn a. Q215AFCHn a Q220AFCHn a QA115AFHH QA120AFHH Circuit s Arc-Fault and Ground-Fault s 06/3/4 Selection/Wiring Diagrams Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard

More information

Types of Circuit Breakers

Types of Circuit Breakers Types of Circuit Breakers Instantaneous Magnetic- Trip-Only Circuit Breakers Instantaneous magnetic-trip-only circuit breakers do not provide overload protection and are used on motor circuits where overload

More information

Square D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions

Square D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions Square D QO Load Centers and Circuit Breakers The leader for safe, reliable, and innovative solutions TM QO Load Centers are built on the Square D reputation for reliability, innovation, and circuit protection

More information

How To Build A Switchboard

How To Build A Switchboard SECTION 16425 SWITCHBOARDS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Requirements for main and distribution switchboards. B. Related Sections: 1. Section 16420 - Service Entrance 2. Section 16430

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Class Catalog 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................

More information

NQ, NF, I-Line, and QMB Panelboard Products. Reliable, Versatile, and Convenient Solutions

NQ, NF, I-Line, and QMB Panelboard Products. Reliable, Versatile, and Convenient Solutions NQ, NF, I-Line, and QMB Panelboard Products Reliable, Versatile, and Convenient Solutions TM Square D Panelboard Family Developed with extensive input from electrical contractors, Square D panelboards

More information

Miniature Circuit Breakers and Supplementary Protectors

Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG

More information

SECTION A. UL rd Edition (2009 Revision effective 9/29/2009).

SECTION A. UL rd Edition (2009 Revision effective 9/29/2009). SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes the materials and installation requirements for Surge Protective Devices (SPDs) and includes

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Disconnect switches Non-fusible Fusible

Disconnect switches Non-fusible Fusible Disconnect switches Non-fusible Fusible Low voltage disconnect switches from ABB ABB is committed to offering high quality and innovative low voltage products. ABB s disconnect switch lines are no exception.

More information

How To Build A Power Line In California

How To Build A Power Line In California LOW VOLTAGE INSTANT SWITCHBOARDS PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install, where indicated, free-standing, deadfront-type low voltage instant switchboard(s) utilizing

More information

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) #500-1000 kcmil SUK1000TA.

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) #500-1000 kcmil SUK1000TA. Uni-PAK : Accessories Selection 2 METER ECHS125 NSK400 SUK350TA Old PAK Accessories Accessories for All-In-One Units Description Catalog Number Description Catalog Number 5th Jaw Kit a Lugs for NEMA Stud

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

How To Make A Low Voltage Power Switchgear

How To Make A Low Voltage Power Switchgear Low Voltage 480V Switchgear General Description Low Voltage metal-enclosed switchgear is used in electric power distribution systems for the control and protection of circuits and equipment. The switchgear

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

QO Load Centers and Circuit Breakers Unsurpassed circuit protection and application flexibility

QO Load Centers and Circuit Breakers Unsurpassed circuit protection and application flexibility QO Load Centers and Circuit Breakers Unsurpassed circuit protection and application flexibility Square D is the leader in circuit protection, a reputation 7 QO Load Centers helped to build. The widest

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

Main Breaker Panel Connectors. Ampere Rating Connectors Suitable for Cu or Al 100 (1) #14 1/0 AWG 125 (1) #4 1/0 AWG 225 (1) #4 AWG 300 kcmil

Main Breaker Panel Connectors. Ampere Rating Connectors Suitable for Cu or Al 100 (1) #14 1/0 AWG 125 (1) #4 1/0 AWG 225 (1) #4 AWG 300 kcmil Circuit / Lighting and Distribution Type P1 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A @ 240 Vac / 100,000 A @ 480/277

More information

SECTION 16429C ( ) GENERATOR QUICK CONNECT SWITCHBOARDS LOW VOLTAGE

SECTION 16429C ( ) GENERATOR QUICK CONNECT SWITCHBOARDS LOW VOLTAGE (26 24 13.02) GENERATOR QUICK CONNECT SWITCHBOARDS LOW VOLTAGE PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install, where indicated, a free-standing, dead-front type low voltage Generator

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

LOW VOLTAGE FRONT ACCESSIBLE MAIN SWITCHBOARD

LOW VOLTAGE FRONT ACCESSIBLE MAIN SWITCHBOARD SECTION 16323 LOW VOLTAGE FRONT ACCESSIBLE MAIN SWITCHBOARD PART 1 - GENERAL 1.01 General: Provide low voltage main switchboard, complete, as indicated, specified and required per Contract Documents. 1.02

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Circuit Breakers. Lug-In/Lug-Out with INSTA-WIRE. Selection. Revised 03/06/13

Circuit Breakers. Lug-In/Lug-Out with INSTA-WIRE. Selection. Revised 03/06/13 Circuit Breakers Lug-In/Lug-Out with INSTA-WIRE 03/06/3 All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix L to catalog number. Consult Siemens

More information

Article 250: Grounding And Bonding

Article 250: Grounding And Bonding Part D: Code Book Questions Article 250: Grounding And Bonding 1.! A ground-fault is an unintentional, electrically conducting connection between an ungrounded! conductor of an electrical circuit and the

More information

GROUNDING AND BONDING. Table of Contents. Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table

GROUNDING AND BONDING. Table of Contents. Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table GROUNDING AND BONDING Table of Contents Grounding Bonding Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table Typical Residential Service Grounding and Bonding Drawing (overhead)

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

General Layout Information (Type SB1, SB2, SB3, IPS) Individually Mounted Service Mains

General Layout Information (Type SB1, SB2, SB3, IPS) Individually Mounted Service Mains General ayout Information (Type SB1, SB2, SB3, IPS) Individually Mounted Service s imensions in Inches (mm) eight Width Pull Section Non- Bussed Max. Bussed UG Amp. evice Rating Type W2 W3 Molded Case

More information

PREFACE. The products covered by this Guide are:

PREFACE. The products covered by this Guide are: PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in

More information

The Offer BULK TRADE PACKS POLY BAG

The Offer BULK TRADE PACKS POLY BAG Electrical The Offer Contractor grade quality Manufactured using the highest quality materials Fully compliant with Australian & New Zealand Safety Standards Market leading innovative products Fully interchangeable

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

NON-FUSIBLE DISCONNECT SWITCHES

NON-FUSIBLE DISCONNECT SWITCHES SIRCO NON-FUSIBLE DISCONNECT SWITCHES Ferraz Shawmut SIRCO disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most

More information

at 240 V and 100 ka at 480 V.

at 240 V and 100 ka at 480 V. Data Bulletin 0611DB0402R01/10 01/2010 Cedar Rapids, IA USA Replaces 0611DB0401R3/08 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications

More information

SECTION 26 24 13.17 SWITCHBOARDS LOW VOLTAGE (COMMERCIAL METERING)

SECTION 26 24 13.17 SWITCHBOARDS LOW VOLTAGE (COMMERCIAL METERING) SWITCHBOARDS LOW VOLTAGE (COMMERCIAL METERING) PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install, where indicated, free-standing, dead-front-type low voltage distribution

More information

CAT ATC MOLDED CASE CIRCUIT BREAKER AND MOLDED CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC MOLDED CASE CIRCUIT BREAKER AND MOLDED CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC MOLDED CASE CIRCUIT BREAKER AND MOLDED CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability

More information

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC ELECTRICAL SERVICE REQUIREMENTS ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC TABLE OF CONTENTS TITLE SECTION NO. List of Approved Electric Utility Service Equipment Requirements Committee

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

Submersible Motor Control Boxes

Submersible Motor Control Boxes Applications QUICK DISCONNECT (QD) & CAPACITOR RUN CONTROL (CRC) These control boxes are designed for use with Franklin 3-wire single-phase submersible motors through 1 hp. STANDARD & DELUXE These control

More information

HOMELINE. Circuit Breaker Load Centers. Class May 1995

HOMELINE. Circuit Breaker Load Centers. Class May 1995 Class 1170 May 1995 HOMELIE Circuit reaker Load Centers COTET Description Class Pages pplication Data...1170...2-5 ccessories...1170...6 Technical Data...1170...7-8 Dimensions...1170...9 Wiring Diagrams...1170...10-11

More information

The Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2

The Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2 Residential Load Centers and Circuit Breakers product The Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

E-Series. Circuit Breaker

E-Series. Circuit Breaker E-Series Circuit Breaker The E-Series hydraulic/magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection,

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

J Power Series. emergency power systems SINGLE POLE CABLE CONNECTORS. Distributed By:

J Power Series. emergency power systems SINGLE POLE CABLE CONNECTORS. Distributed By: J Power Series Page 1 introduces the new E-Z1016 J Series Connectors. The E-Z1016 series has been developed to provide you with faster and easier assembly and disassembly. The E-Z Series is intermateable

More information

Definite Purpose Control

Definite Purpose Control Definite Purpose Control Index Description Page Number General Application and Features... Pole AC Contactors - DP..., and Pole Contactors - DP and DP... Two Pole Contactors Mechanically and Electrically

More information

101 BASICS SERIES LEARNING MODULE 10: LOADCENTERS. Cutler-Hammer

101 BASICS SERIES LEARNING MODULE 10: LOADCENTERS. Cutler-Hammer 101 BASICS SERIES LEARNING MODULE 10: LOADCENTERS Cutler-Hammer WELCOME Welcome to Module 10, which is about loadcenters. A loadcenter is a device that delivers electricity from a supply source to loads

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

Rackmount Distribution Panel Models: DST-20A DST-10

Rackmount Distribution Panel Models: DST-20A DST-10 Rackmount Distribution Panel Models: DST-20A DST-10 31ZT INSTALLATION/OPERATION INSTRUCTIONS Model DST-20A pictured with 12 optional breakers installed Table of Contents Section Topic Page I) OVERVIEW

More information

Solar Meter Load Center Combinations. West Coast Meter Combinations Title 24 Solutions.

Solar Meter Load Center Combinations. West Coast Meter Combinations Title 24 Solutions. Solar Meter Load Center Combinations West Coast Meter Combinations Title 24 Solutions www.usa.siemens.com/residential Siemens Title 24 Solar Meter Combination Solutions On July 1, 2014 major revisions

More information

SPR-5200 and SPR-4600 Installation and Operation Manual

SPR-5200 and SPR-4600 Installation and Operation Manual SPR-5200 and SPR-4600 Installation and Operation Manual SunPower Corporation Document # 001 69178 Rev** 1 SunPower Inverter SPR-5200 and SPR-4600 Table of Contents SunPower Corporation Document # 001 69178

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Installation Manual Series, 7ATS, 7ACTS, 7ADTS G, Q, S, & U design Automatic Transfer Switches. Installation A DANGER

Installation Manual Series, 7ATS, 7ACTS, 7ADTS G, Q, S, & U design Automatic Transfer Switches. Installation A DANGER Installation Manual Installation Manual ASCO 7ATS, 7ACTS, 7ADTS 7000 Series, 7ATS, 7ACTS, 7ADTS G, Q, S, & U design Automatic Transfer Switches DANGER is used in this manual to warn of a hazard situation

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

AEP. Meter Socket Adapters. Standard Meter Socket Adapter. Low Profile Meter Socket Adapter

AEP. Meter Socket Adapters. Standard Meter Socket Adapter. Low Profile Meter Socket Adapter Meter Socket Adapters Standard Meter Socket Adapter The UEA-200 Meter Socket Adapter may be used to convert meter sockets to test or control applications. Convert up to 10 jaws in 200 Amp meter socket

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS

More information

Switchboards. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

Switchboards. Siemens STEP 2000 Course. STEP 2000 Courses distributed by Siemens STEP 2000 Course Switchboards It's easy to get in STEP! Download any course. Hint: Make sure you download all parts for each course and the test answer form. Complete each chapter and its review

More information

RPA PROJECT NO SECTION Page 1 of 5 BW&A NO SECTION SWITCHBOARDS

RPA PROJECT NO SECTION Page 1 of 5 BW&A NO SECTION SWITCHBOARDS RPA PROJECT NO. 2015225.00 SECTION 26-24-13 - Page 1 of 5 PART 1 - GENERAL 1.01 DESCRIPTION SECTION 26-24-13 A. All work specified in this Section shall comply with the provisions of Section 26-05-05.

More information

MCCB Distribution Panel

MCCB Distribution Panel The Power of Technology MCCB Distribution Panel Range : 4, 6, 8, 10 & 12 ways. Incoming 160A / 250A / 400A / 630A. Outgoing 160A / 250A No. of poles of MCCB 3 / 4. Fully shrouded bus bar with high short

More information

ZONESENTINEL SERIES. AC Panel Transient Voltage Surge Suppressors. Installation Instructions & User Manual

ZONESENTINEL SERIES. AC Panel Transient Voltage Surge Suppressors. Installation Instructions & User Manual ZONESENTINEL SERIES AC Panel Transient Voltage Surge Suppressors Installation Instructions & User Manual INTRODUCTION This document explains how to install the ZoneSentinel Series of AC Panel Surge Protective

More information

INSTALLATION AND OPERATING INSTRUCTIONS. Q-Series MANUAL TRANSFER SWITCHES FROM

INSTALLATION AND OPERATING INSTRUCTIONS. Q-Series MANUAL TRANSFER SWITCHES FROM INSTALLATION AND OPERATING INSTRUCTIONS Q-Series MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel Shallow well

More information

Florida utilities Florida Power & Light Tampa Electric Company Gulf Power Duke Energy

Florida utilities Florida Power & Light Tampa Electric Company Gulf Power Duke Energy Metering Mounting Equipment MTRFLA-14 Florida utilities Florida Power & Light Tampa Electric Company Gulf Power Duke Energy Introduction Company History In 1993, Eaton s B-Line Business acquired Circle

More information

I-Line Combo Panelboard

I-Line Combo Panelboard I-Line Save time and space by combining I-Line and NQ/NF sections in one panelboard. Explore the I-Line 3D Interactive Model! Scan this QR code with your smartphone to download the itunes 3D Interactive

More information

Rackmount Distribution Panel Models: DST-20A DST-10

Rackmount Distribution Panel Models: DST-20A DST-10 Rackmount Distribution Panel Models: DST-20A DST-10 31ZT Installation/Operation Instructions Model DST-20A pictured with 10 optional breakers installed Table of Contents Section Topic Page I) OVERVIEW

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Applications. Remote Display Mounting Kits

Applications. Remote Display Mounting Kits June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge

More information

PowerWave Bus System Specification

PowerWave Bus System Specification BUSWAY SYSTEM 1.0 SUMMARY 1.1 This specification covers the electrical characteristics and general requirements for a continuous opening, low voltage vertical or horizontal distribution system (busway).

More information

CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH

CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Breakers and Switches. Enclosed switches eot Enclosed disconnect switches Manual motor controllers

Breakers and Switches. Enclosed switches eot Enclosed disconnect switches Manual motor controllers Breakers and Switches Enclosed switches eot Enclosed disconnect switches Manual motor controllers The next generation of enclosed switches General information The eot series of enclosed manual motor controllers

More information

MNPV2 & 4 Prewired Installation Instructions

MNPV2 & 4 Prewired Installation Instructions MNPV2 & 4 Prewired Installation Instructions MNPV2-MC4 Shown MNPV4-TYCO Shown The Pre-wired MNPV combiner is rated for outdoor use. Designed for combining high voltage strings using 10mm x 38mm fuses up

More information

Transfer Switches. LT III Series - Automatic. Description. Features. 30 to 260 Amps

Transfer Switches. LT III Series - Automatic. Description. Features. 30 to 260 Amps Transfer Switches LT III Series - Automatic 30 to 260 Amps Description The LT III Automatic Transfer Switch combines reliability and flexibility in a small, economical package for transferring loads between

More information