Note: Have a look at the MX upgrade doc for you to get an idea of the process.
|
|
|
- Hilda Burns
- 10 years ago
- Views:
Transcription
1 How to perform a quick direct upgrade from XenServer 5.5 UP2 / everrun MX6.0.0 (with any HF level) to XenServer 5.6 SP2 / EverRun MX HF* without un-protecting the PVM(s) Date: 17-August-2012 Revision: 1.0 HF*: This can be any MX Hotfix level release (HF1 or HF2...etc). In this example, we are upgrading to MX HF1. Acronym / Abbreviations HF = Hotfix eac = everrun Availability Centre CLI = Command Line Interface OS = Operation System UP = Update Pack SP = Service Pack Marathon Software Downloads All Marathon everrun related software can be downloaded from the Marathon Support Portal under (you need login credentials). Upon logging in, click the DOWNLOAD button. All of Marathon s everrun products are downloaded from here. Under Select Product, specify the categories of interest to reduce the choices. Default product select will be everrun MX Pre-upgrade requirements Have a look at the MX upgrade doc for you to get an idea of the process. This procedure will speed up the process and time and reduce the downtime of the PVM's by upgrading direct from MX to MX without going to MX first. This can be performed by direct installing to MX SP or MX HF* (or any newer hotfix level). Once MX is installed, you will not be able to roll back to a previous release of everrun. Chose a version of everrun MX that you will base all future upgrades on. You can find the upgrade guide Upgrade.pdf from Marathon Support Portal download area under everrun MX 6.1.1HF1 Documentation Set (everrun-mx-v6.1.1hf1-documentation.exe). Important that you read the everrun MX Read Me First doc in the Download area for MX Information might be relevant to your installation.
2 Pre-Upgrade Procedure 1- Open a new Marathon support ticket and request an upgrade license from MX to MX You need to give your everrun MX6.0.0 license in the ticket. 2- Download from the Marathon Support Portal, the everrun MX HF1 installation kit: everrun MX Product CD Image (ISO) including Hot Fix Level 1 (HF1) and associated files (everrun-6.1.1hf1-install.exe). This will include, when unpacked: everrun MX Product CD image (everrun-6.1.1hf1-install.iso) XenServer 5.6 SP2 install ISO image (XenServer SP2-install-cd.iso) Installation kit for XenCentre Management Software 5.6 SP2 (XenServer SP2- XenCentre.msi) Marathon Citrix OEM License file for XenServer 5.6 SP2 (marathon.lic) 3- Upgrade your XenCentre client on all your windows workstation/laptop to version SP2 using the XenServer SP2-XenCenter.msi installer. 4- Using WinRAR freeware or any other file extraction software tool from an ISO image, extract the "windows-pvdrivers-xensetup.exe" under "client_install" directory from the XenServer SP2-install-cd.iso ISO image. 5- Burn the XenServer SP2-install-cd.iso on a CD (Make 2 copies please), or if the XenServer hardware has a remote management facility for Virtual CD like in HP ilo, DELL idrac or IBM IMM...etc, then you can use the map the ISO files to a Virtual CD on the Servers. 6- Using WinRAR or any other file extraction software tool from an ISO image, extract the following files/directory from the everrun-6.1.1hf1-install.iso ISO image: everrun-6.1.1hf1-installer.bin Update_PVM_6.1.1HF1.exe CitrixHotfixes (extract this directory that will contain XenServer 5.6 SP2 HF16) if you are also using Quorum Services, then extract also the Setup_QSVC_6.1.1HF1.exe. 7- Download and installed WinSCP on your laptop/workstation. If you already do not have this already installed on your Laptop, then please do so, as it is a very handy tool to have. Upgrade procedure Because you are also going to upgrade the XenServer Os itself, from 5.5 UP2 to 5.6 SP2, any VM and PVM on that Pool needs to be shutdown, therefore follow this upgrade path while maintaining the protected VM. Verify that all PVMs are fully redundant (eac indicates all OK, with no mirror copies required). If there
3 is a problem, then stop immediately and resolve the problem before you continue with the upgrade procedure. If all OK, then: 1- Shutdown all PVMs and non-protected VMs 2- IMPORTANT - Any PVM s that have parameter auto-power-on=true, needs to be turned off =false. The command to set the auto-power-on to false is: # ev pvm-param-set auto-power-on=false uuid=<pvm-uuid that have auto-power-on set to true> 3- Apply via XenCentre the Marathon OEM XenServer Free license marathon.xslic to both Xen1 and Xen2 in the Pool (Very important that you do this before you carry out the XenServer 5.6 SP2 installation). This will replace the current one you have: XenCentre Tools (tab) License Manager... Select one at a time the XenServer host and select Apply Activation Key.. from the Activate Free XenServer dropdown box. A browse window is displayed. Browse for the marathon.xslic license file and click OPEN. A pop up box is displayed that shows a non-expiry license (Never expires). 4- Access the Marathon eac web interface eac and License MX6.1.1 using the Key that was delivered to you via from Marathon. MX license keys are valid for older versions that meet the pre-requisite for this upgrade 5- Determine possible sources of automatic failover of the pool master, and use the appropriate commands to disable it: # ev pool-param-get param-name=master-failover-via If master failover indicates "manual", proceed to the next step (6). If master failover indicates "everrun", disable it as follows: # ev pool-master-failover-disable force 6- XenServer 5.6 SP2 installation: XenServer 5.6 SP2 installation is relative fast, therefore we recommend that you do one XenServer host at a time. The reason is if anything goes wrong with the XenServer upgrade and that XenServer host is damaged, you still would have the other one intact and can be booted up with the old version. Via XenCentre or eac, shutdown both Master and Slave XenServer Hosts. 7- Start the XenServer 5.6 SP2 installation on the SLAVE XenServer hosts. Choose an "upgrade install" as an installation method. This will upgrade your XenServer 5.5 UP2 to 5.6 SP2 and all the dom0 configuration will be kept unchanged. When the upgrade installation goes through without any problems, do not reboot the XenServer host yet.
4 Next, upgrade the MASTER XenServer host. After upgrading both XenServer hosts to XenServer 5.6 SP2, reboot MASTER XenServer host first and then the SALVE. Once both XenServer hosts are up, you will end up with XenServer 5.6 SP2 in a Pool. All the VM's and PVM stay unchanged. Confirm that the XenServer Pool is up and all looks good in the XenCentre. at this stage, the PVMs or VMs should still be down. 8- Installing MX6.1.1 HF1 on both Xen Hosts in parallel: Using WinSCP from your laptop or Desktop and upload over the everrun-6.1.1hf1- installer.bin and CitrixHotfixes directory to each XenServer (e.g under /tmp directory). Under /tmp, you should have the following listed: drwxr-xr-x 2 root root 4096 Aug 2 13:01 CitrixHotfixes -rw-r--r-- 1 root root Jul 2617:47 everrun-6.1.1hf1-installer.bin 9- To install MX HF1 (parallel on both XenServers): # cd tmp # bash everrun-6.1.1hf1-installer.bin install Important If the CitrixHostfixes directory is not located on /tmp, then MX 6.1.1HF1 will fail to install. Part of the MX6.1.1HF1 installation is to look if CitrixHostfixes directory is available and the XenServer 5.6 SP2 HF16 is XS56ESP2016.xsupdate available in that directory. Part of the MX 6.1.1HF1 installation is to install Citrix XenServer 5.6 SP2 HF16. After MX6.1.1 HF1 is installed, reboot both XenServers in Parallel via XenCentre. 10- Confirm that you can access and login to the Marathon Web Interface eac and check that all is OK and the PVMs and VMs are still down. Once all is OK, use winscp from your laptop or Desktop or from the XenCentre XenServer console (CLI), delete the everrun-6.1.1hf*-installer.bin and CitrixHotfixes directory from each XenServer (e.g under /tmp directory). 11- Start up the PVM and upgrade its PVM driver, following the guide in page 24 & 25 in the MX HF1 upgrade guide, using the "Update_PVM_6.1.1HF1.exe" and then accessing the location of the "windows-pvdrivers-xensetup.exe" file. IMPROTANT: When the XenTool part gets updated, you may see a pop-up screen with the following message: Failed to install drivers on one of the XenServer devices. Because the Marathon drivers have replaced the XenServer drivers, this is not a problem. Allow the XenServer Tools installation to run to completion, but do not select the option to reboot now, choose I want to manually reboot later. PVM gets rebooted automatically after the installation.
5 12- Once the PVM is up and running again and everything is online, enable the auto-start of the PVM(s) if they where disabled at step 2 above, either via eac or CLI: # ev pvm-param-set auto-power-on=true uuid=<pvm-uuid that auto-power-on needs to be set to true> 13- If you disabled everrun master failover in a previous step 5, then re-enable it: # ev pool-master-failover-enable 14- If Quorum Services been used, then update the Preferred and Alternate server with the Setup_QSVC_6.1.1HF1.exe file.
Release Notes. Software Versions and Hardware Supported
everrun Release Notes NOTE: For the most recent documentation and updates, please log in to the everrun customer web portal and download the latest versions. The link is: http://www.stratus.com/stratus/home/services/customersupport
Setup and Installation Guide
Setup and Installation Guide Release 6.2 Rev A July 2013 NOTICE The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET FORTH IN A WRITTEN AGREEMENT SIGNED
Parallels Virtuozzo Containers 4.6 for Windows
Parallels Parallels Virtuozzo Containers 4.6 for Windows Upgrade Guide Copyright 1999-2010 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd. c/o Parallels International
SQL Server 2008 R2 Express Edition Installation Guide
Hardware, Software & System Requirements for SQL Server 2008 R2 Express Edition To get the overview of SQL Server 2008 R2 Express Edition, click here. Please refer links given below for all the details
WhatsUp Gold v16.3 Installation and Configuration Guide
WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard
VMTurbo Operations Manager 4.5 Installing and Updating Operations Manager
VMTurbo Operations Manager 4.5 Installing and Updating Operations Manager VMTurbo, Inc. One Burlington Woods Drive Burlington, MA 01803 USA Phone: (781) 373---3540 www.vmturbo.com Table of Contents Introduction
Installing a Symantec Backup Exec Agent on a SnapScale Cluster X2 Node or SnapServer DX1 or DX2. Summary
Technical Bulletin Application Note April 2013 Installing a Symantec Backup Exec Agent on a SnapScale Cluster X2 Node or SnapServer DX1 or DX2 Summary This application note describes how to install the
Setting up Citrix XenServer for 2X VirtualDesktopServer Manual
Setting up Citrix XenServer for 2X VirtualDesktopServer Manual URL: www.2x.com E-mail: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples
Setting up VMware ESXi for 2X VirtualDesktopServer Manual
Setting up VMware ESXi for 2X VirtualDesktopServer Manual URL: www.2x.com E-mail: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples
Program Update IPedge Feature Description IPedge Feature Desc. 8/2/13
Program Update IPedge Feature Description IPedge Feature Desc. 8/2/13 OVERVIEW The IPedge program update process is controlled through Enterprise Manager. The software update can be performed using three
Citrix XenClient 1.0
White Paper Citrix XenClient Citrix XenClient 1.0 Proof of Concept Implementation Guide www.citrix.com Contents Introduction... 3 Hardware and Software Requirements... 3 Installation and Configuration...
Microsoft Diagnostics and Recovery Toolset 7 Evaluation Guide
Microsoft Diagnostics and Recovery Toolset 7 Evaluation Guide White Paper Descriptor This document provides administrators with information and steps-by-step technique for deploying Microsoft Diagnostics
SA Citrix Virtual Desktop Infrastructure (VDI) Configuration Guide
SA Citrix Virtual Desktop Infrastructure (VDI) Configuration Guide Published July 2015 This document covers steps to configure Citrix VDI on Pulse Secure s SA Series SSL VPN platforms. It also covers brief
Quick Start Guide. Citrix XenServer Hypervisor. Server Mode (Single-Interface Deployment) Before You Begin SUMMARY OF TASKS
Quick Start Guide VX VIRTUAL APPLIANCES If you re not using Citrix XenCenter 6.0, your screens may vary. Citrix XenServer Hypervisor Server Mode (Single-Interface Deployment) 2013 Silver Peak Systems,
LT Auditor+ 2013. Windows Assessment SP1 Installation & Configuration Guide
LT Auditor+ 2013 Windows Assessment SP1 Installation & Configuration Guide Table of Contents CHAPTER 1- OVERVIEW... 3 CHAPTER 2 - INSTALL LT AUDITOR+ WINDOWS ASSESSMENT SP1 COMPONENTS... 4 System Requirements...
efolder BDR for Veeam Cloud Connection Guide
efolder BDR for Veeam Cloud Connection Guide Setup Connect Preload Data uh6 efolder BDR Guide for Veeam Page 1 of 36 INTRODUCTION Thank you for choosing the efolder Cloud for Veeam. Using the efolder Cloud
GWAVA 5. Migration Guide for Netware GWAVA 4 to Linux GWAVA 5
GWAVA 5 Migration Guide for Netware GWAVA 4 to Linux GWAVA 5 Copyright 2010 GWAVA, Inc. All rights reserved. Content may not be reproduced without permission. http://www.gwava.com Overview While GWAVA
Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures. Goliath Performance Monitor Installation Guide v11.
Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures Goliath Performance Monitor Installation Guide v11.5 (v11.5) Document Date: March 2015 www.goliathtechnologies.com
SERVER CLOUD DISASTER RECOVERY. User Manual
SERVER CLOUD DISASTER RECOVERY User Manual 1 Table of Contents 1. INTRODUCTION... 3 2. ACCOUNT SETUP OVERVIEW... 3 3. GETTING STARTED... 6 3.1 Sign up... 6 4. ACCOUNT SETUP... 8 4.1 AWS Cloud Formation
Accessing RCS IBM Console in Windows Using Linux Virtual Machine
Accessing RCS IBM Console in Windows Using Linux Virtual Machine For Graphics Simulation Experiment, Real Time Applications, ECSE 4760 Quan Wang Department of ECSE, Rensselaer Polytechnic Institute March,
Bare Metal Recovery Quick Start Guide
Bare Metal Recovery Quick Start Guide Revisions Document Control Version 5.4.3 Status Changes Date Final Created. August 2014 Copyright 2003-2014 Intronis, Inc. All rights reserved. 1 Table of Contents
Citrix Mac OS X Guide
Citrix Mac OS X Guide Rev 6 1/24/2013 2 TABLE OF CONTENTS Section 1 Section 1.1 Safari Browser... 3-5 Section 1.2 Manually Install Java... 6 Section 1.3 Configure Java... 6-7 Section 1.4 Enable Java...
HP PolyServe Software 4.1.0 upgrade guide
HP StorageWorks HP PolyServe Software 4.1.0 upgrade guide This document describes how to upgrade to HP PolyServe Matrix Server 4.1.0, HP PolyServe Software for Microsoft SQL Server 4.1.0, and HP PolyServe
If you re not using Citrix XenCenter 6.0, your screens may vary. Required Virtual Interface Maps to... mgmt0. virtual network = mgmt0 wan0
If you re not using Citrix XenCenter 6.0, your screens may vary. VXOA VIRTUAL APPLIANCES Citrix XenServer Hypervisor In-Line Deployment (Bridge Mode) 2012 Silver Peak Systems, Inc. Support Limitations
How to Backup XenServer VM with VirtualIQ
How to Backup XenServer VM with VirtualIQ 1. Using Live Backup of VM option: Live Backup: This option can be used, if user does not want to power off the VM during the backup operation. This approach takes
XenClient Enterprise Upgrade Guide
XenClient Enterprise Upgrade Guide Version 5.0 August 12, 2013 Table of Contents About this Document...4 Step 1: Get the Updated Software...4 Step 2: Upgrade XenClient Enterprise Synchronizer...4 Step
SA Citrix Virtual Desktop Infrastructure (VDI) Configuration Guide
SA Citrix Virtual Desktop Infrastructure (VDI) Configuration Guide This document covers steps to configure Citrix VDI on Juniper Network s SA Series SSL VPN platforms. It also covers brief overview of
Universal Management Service 2015
Universal Management Service 2015 UMS 2015 Help All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording,
Configure the idrac Remote Access Console
Configure the idrac Remote Access Console If your ExtraHop system is deployed in a data center or other remote environment, you might need to remotely access the console and its power-management features.
Installation Guide for WebSphere Application Server (WAS) and its Fix Packs on AIX V5.3L
Installation Guide for WebSphere Application Server (WAS) and its Fix Packs on AIX V5.3L Introduction: This guide is written to help any person with little knowledge in AIX V5.3L to prepare the P Server
Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment
Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment Version 2.0 This tutorial will walk you through how to create a bootable USB drive to enter into a WINPE
Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures. Goliath Performance Monitor Installation Guide v11.
Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures Goliath Performance Monitor Installation Guide v11.6 (v11.6) Document Date: August 2015 www.goliathtechnologies.com
1Y0-A09. Implementing Citrix XenServer Enterprise Edition 5.0. http://www.examskey.com/1y0-a09.html
Citrix 1Y0-A09 Implementing Citrix XenServer Enterprise Edition 5.0 TYPE: DEMO http://www.examskey.com/1y0-a09.html Examskey Citrix 1Y0-A09 exam demo product is here for you to test the quality of the
Portions of this product were created using LEADTOOLS 1991-2009 LEAD Technologies, Inc. ALL RIGHTS RESERVED.
Installation Guide Lenel OnGuard 2009 Installation Guide, product version 6.3. This guide is item number DOC-110, revision 1.038, May 2009 Copyright 1992-2009 Lenel Systems International, Inc. Information
Deploying Red Hat Enterprise Virtualization On Tintri VMstore Systems Best Practices Guide
TECHNICAL WHITE PAPER Deploying Red Hat Enterprise Virtualization On Tintri VMstore Systems Best Practices Guide www.tintri.com Contents Intended Audience... 4 Introduction... 4 Consolidated List of Practices...
Moving the TRITON Reporting Databases
Moving the TRITON Reporting Databases Topic 50530 Web, Data, and Email Security Versions 7.7.x, 7.8.x Updated 06-Nov-2013 If you need to move your Microsoft SQL Server database to a new location (directory,
4.0 SP1 (4.0.1.0) November 2014 702P03296. Xerox FreeFlow Core Installation Guide: Windows Server 2008 R2
4.0 SP1 (4.0.1.0) November 2014 702P03296 Installation Guide: Windows Server 2008 R2 2014 Xerox Corporation. All rights reserved. Xerox, Xerox and Design, FreeFlow, and VIPP are trademarks of Xerox Corporation
ACTIVE DIRECTORY DEPLOYMENT
ACTIVE DIRECTORY DEPLOYMENT CASAS Technical Support 800.255.1036 2009 Comprehensive Adult Student Assessment Systems. All rights reserved. Version 031809 CONTENTS 1. INTRODUCTION... 1 1.1 LAN PREREQUISITES...
How to install software on VMware ESXi 4.0/4.1
How to install software on VMware ESXi 4.0/4.1 This section describes the installation and configuration of the Software on VMware ESXi 4.0/4.1 Server. Notice: the version of VMware ESXi 4.0/4.1 should
VELOCITY. Quick Start Guide. Citrix XenServer Hypervisor. Server Mode (Single-Interface Deployment) Before You Begin SUMMARY OF TASKS
If you re not using Citrix XenCenter 6.0, your screens may vary. VELOCITY REPLICATION ACCELERATOR Citrix XenServer Hypervisor Server Mode (Single-Interface Deployment) 2013 Silver Peak Systems, Inc. This
STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER
Notes: STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER 1. These instructions focus on installation on Windows Terminal Server (WTS), but are applicable
Citrix XenServer 5.6 OpenSource Xen 2.6 on RHEL 5 OpenSource Xen 3.2 on Debian 5.0(Lenny)
Installing and configuring Intelligent Power Protector On Xen Virtualized Architecture Citrix XenServer 5.6 OpenSource Xen 2.6 on RHEL 5 OpenSource Xen 3.2 on Debian 5.0(Lenny) 1 Introduction... 3 1. Citrix
Thinspace deskcloud. Quick Start Guide
Thinspace deskcloud Quick Start Guide Version 1.2 Published: SEP-2014 Updated: 16-SEP-2014 2014 Thinspace Technology Ltd. All rights reserved. The information contained in this document represents the
simplify monitoring Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures
simplify monitoring Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures Simplify Monitoring Installation Guide 11.4 (v11.4) Document Date: February 2015 www.tricerat.com
Acronis Backup & Recovery 10 Server for Windows. Installation Guide
Acronis Backup & Recovery 10 Server for Windows Installation Guide Table of Contents 1. Installation of Acronis Backup & Recovery 10... 3 1.1. Acronis Backup & Recovery 10 components... 3 1.1.1. Agent
How To Install Database Oasis On A Computer Or Computer (For Free)
INSTALLATION INSTRUCTIONS Table of Contents Installation Instructions 1 Table of Contents 1 System Requirements 2 Installation 3 Selecting where to Install the Professional Server 3 Installing Prerequisites
XenClient Enterprise Synchronizer Migration
XenClient Enterprise Synchronizer Migration Applicability This document is applicable to XenClient Synchronizer version 5.1. The information in this document also applies to earlier versions of XenClient,
Quick Start Guide. IT Management On-Demand
1 Quick Start Guide Quick Start Guide IT Management On-Demand Introduction... 2 Getting Started... 3 Planning Your Deployment... 5 Performing a Test Deployment... 6 Enterprise Deployment Options... 8 Remote
Administration Guide. . All right reserved. For more information about Specops Gpupdate and other Specops products, visit www.specopssoft.
. All right reserved. For more information about Specops Gpupdate and other Specops products, visit www.specopssoft.com Copyright and Trademarks Specops Gpupdate is a trademark owned by Specops Software.
Montefiore Portal Quick Reference Guide
Montefiore Portal Quick Reference Guide Montefiore s remote portal allows users to securely access Windows applications, file shares, internal web applications, and more. To use the Portal, you must already
Deployment Guide: Unidesk and Hyper- V
TECHNICAL WHITE PAPER Deployment Guide: Unidesk and Hyper- V This document provides a high level overview of Unidesk 3.x and Remote Desktop Services. It covers how Unidesk works, an architectural overview
Citrix XenServer 6.0.2 Emergency Network Reset. Published Wednesday, 29 February 2012 1.0 Edition
Citrix XenServer 6.0.2 Emergency Network Reset Published Wednesday, 29 February 2012 1.0 Edition Citrix XenServer 6.0.2 Emergency Network Reset Copyright 2012 Citrix Systems. Inc. All Rights Reserved.
PowerPanel Business Edition Installation Guide
PowerPanel Business Edition Installation Guide For Automatic Transfer Switch Rev. 5 2015/12/2 Table of Contents Introduction... 3 Hardware Installation... 3 Install PowerPanel Business Edition Software...
Product Overview Release 6.2 Rev A July 2013
Product Overview Release 6.2 Rev A July 2013 NOTICE The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET FORTH IN A WRITTEN AGREEMENT SIGNED BY AN AUTHORIZED
The safer, easier way to help you pass any IT exams. Exam : 9L0-518. OS X Server Essentials 10.8 Exam. Title : Version : Demo 1 / 6
Exam : 9L0-518 Title : OS X Server Essentials 10.8 Exam Version : Demo 1 / 6 1.In Server app, which procedure will configure OS X Server to let members of a specific group use the Messages service? A.
Using Group Policies to Install AutoCAD. CMMU 5405 Nate Bartley 9/22/2005
Using Group Policies to Install AutoCAD CMMU 5405 Nate Bartley 9/22/2005 Before we get started This manual provides a step-by-step process for creating a Group Policy that will install AutoCAD to a Windows
VX 9000E WiNG Express Manager INSTALLATION GUIDE
VX 9000E WiNG Express Manager INSTALLATION GUIDE 2 VX 9000E WiNG Express Manager Service Information If you have a problem with your equipment, contact support for your region. Support and issue resolution
VMware Mirage Web Manager Guide
Mirage 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document,
Server & Workstation Installation of Client Profiles for Windows
C ase Manag e m e n t by C l i e n t P rofiles Server & Workstation Installation of Client Profiles for Windows T E C H N O L O G Y F O R T H E B U S I N E S S O F L A W General Notes to Prepare for Installing
XenClient Enterprise Synchronizer Installation Guide
XenClient Enterprise Synchronizer Installation Guide Version 5.1.0 March 26, 2014 Table of Contents About this Guide...3 Hardware, Software and Browser Requirements...3 BIOS Settings...4 Adding Hyper-V
Virtual Appliances. Virtual Appliances: Setup Guide for Umbrella on VMWare and Hyper-V. Virtual Appliance Setup Guide for Umbrella Page 1
Virtual Appliances Virtual Appliances: Setup Guide for Umbrella on VMWare and Hyper-V Virtual Appliance Setup Guide for Umbrella Page 1 Table of Contents Overview... 3 Prerequisites... 4 Virtualized Server
Acronis Backup & Recovery 10 Workstation. Installation Guide
Acronis Backup & Recovery 10 Workstation Installation Guide Table of Contents 1. Installation of Acronis Backup & Recovery 10... 3 1.1. Acronis Backup & Recovery 10 components... 3 1.1.1. Agent for Windows...
Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive
Dell DR4000 Disk Backup System Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive Storage Engineering Dell Product Group February 2012 THIS
SHAREPOINT 2013 IN INFRASTRUCTURE AS A SERVICE
SHAREPOINT 2013 IN INFRASTRUCTURE AS A SERVICE Contents Introduction... 3 Step 1 Create Azure Components... 5 Step 1.1 Virtual Network... 5 Step 1.1.1 Virtual Network Details... 6 Step 1.1.2 DNS Servers
Changing Your Cameleon Server IP
1.1 Overview Technical Note Cameleon requires that you have a static IP address defined for the server PC the Cameleon server application runs on. Even if the server PC has a static IP address, you may
STIDistrict Server Replacement
STIDistrict Server Replacement Major Steps Defined This document addresses how to migrate data and applications from an existing STIDistrict (SQL) Server to a new machine. There will be 8 major steps:
GPU virtualization with Citrix XenDesktop, using NVIDIA GRID graphics board on VMware vsphere 6
Reviewer's Guide Reviewer s Guide for HDX 3D Pro GPU virtualization with Citrix XenDesktop, using NVIDIA GRID graphics board on VMware vsphere 6 Citrix HDX 3D Pro supports NVIDIA GRID vgpu on both Citrix
How To Enable A Websphere To Communicate With Ssl On An Ipad From Aaya One X Portal 1.1.3 On A Pc Or Macbook Or Ipad (For Acedo) On A Network With A Password Protected (
Avaya one X Portal 1.1.3 Lightweight Directory Access Protocol (LDAP) over Secure Socket Layer (SSL) Configuration This document provides configuration steps for Avaya one X Portal s 1.1.3 communication
Digi Connect Wan 3G Application Guide Update the firmware, backup and restore the configuration of a Digi Connect Wan 3G using a USB flash drive.
1. Configure and prepare required files on the USB flash drive to allow firmware update and configuration backup/restore. Objective: Step by step instructions to upgrade the firmware, backup and restore
Team Foundation Server 2010, Visual Studio Ultimate 2010, Team Build 2010, & Lab Management Beta 2 Installation Guide
Page 1 of 243 Team Foundation Server 2010, Visual Studio Ultimate 2010, Team Build 2010, & Lab Management Beta 2 Installation Guide (This is an alpha version of Benjamin Day Consulting, Inc. s installation
Livezilla How to Install on Shared Hosting http://www.jonathanmanning.com By: Jon Manning
Livezilla How to Install on Shared Hosting By: Jon Manning This is an easy to follow tutorial on how to install Livezilla 3.2.0.2 live chat program on a linux shared hosting server using cpanel, linux
Acronis Backup & Recovery 11
Acronis Backup & Recovery 11 Quick Start Guide Applies to the following editions: Advanced Server Virtual Edition Advanced Server SBS Edition Advanced Workstation Server for Linux Server for Windows Workstation
Note: With v3.2, the DocuSign Fetch application was renamed DocuSign Retrieve.
Quick Start Guide DocuSign Retrieve 3.2.2 Published April 2015 Overview DocuSign Retrieve is a windows-based tool that "retrieves" envelopes, documents, and data from DocuSign for use in external systems.
VeriCentre 3.0 Upgrade Pre-Installation and Post Installation Guidelines
VeriCentre 3.0 Upgrade Pre-Installation and Post Installation Guidelines * For actual installation steps, please refer to the VeriCentre 3.0 Installation guide that came with the VeriCentre 3.0 software.
Installation and Deployment
Installation and Deployment Help Documentation This document was auto-created from web content and is subject to change at any time. Copyright (c) 2016 SmarterTools Inc. Installation and Deployment SmarterStats
The RT module VT6000 (VT6050 / VT6010) can be used to enhance the RT. performance of CANoe by distributing the real-time part of CANoe to a
Getting started with VT6000 and VT6104 The RT module VT6000 (VT6050 / VT6010) can be used to enhance the RT performance of CANoe by distributing the real-time part of CANoe to a dedicated RT execution
Synchronizer Installation
Synchronizer Installation Synchronizer Installation Synchronizer Installation This document provides instructions for installing Synchronizer. Synchronizer performs all the administrative tasks for XenClient
Moving the Web Security Log Database
Moving the Web Security Log Database Topic 50530 Web Security Solutions Version 7.7.x, 7.8.x Updated 22-Oct-2013 Version 7.8 introduces support for the Web Security Log Database on Microsoft SQL Server
Accessing the FTP Server - User Manual
CENTRAL BANK OF CYPRUS Accessing the FTP Server - User Manual IT Department, CENTRAL BANK OF CYPRUS TABLE OF CONTENTS 1 EXECUTIVE SUMMARY... 1 1.1 AUDIENCE... 1 1.2 SCOPE... 1 2 CHANGES FROM THE OLD FTP
Table of Contents. CHAPTER 1 About This Guide... 9. CHAPTER 2 Introduction... 11. CHAPTER 3 Database Backup and Restoration... 15
Table of Contents CHAPTER 1 About This Guide......................... 9 The Installation Guides....................................... 10 CHAPTER 2 Introduction............................ 11 Required
Dell Command Integration Suite for System Center 2012. Version 4.1. Installation Guide
Dell Command Integration Suite for System Version 4.1 Installation Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
Citrix XenServer Workload Balancing 6.5.0 Quick Start. Published February 2015 1.0 Edition
Citrix XenServer Workload Balancing 6.5.0 Quick Start Published February 2015 1.0 Edition Citrix XenServer Workload Balancing 6.5.0 Quick Start Copyright 2015 Citrix Systems. Inc. All Rights Reserved.
Galveston College Wireless Network Users Setup Guide Version 1.0
Galveston College Wireless Network Users Setup Guide Version 1.0 TABLE OF CONTENT 1 DOCUMENT CONTROL RECORD... 3 2 ISSUE AND AMENDMENT RECORD... 3 3 GENERAL... 3 3.1 INTRODUCTION...3 3.2 OBJECTIVE... 3
Overview... 1 Requirements... 1. Installing Roles and Features... 3. Creating SQL Server Database... 9 Setting Security Logins...
Contents CHAPTER 1 IMail Server using Failover Clustering Overview... 1 Requirements... 1 CHAPTER 2 IIS Installing Roles and Features... 3 CHAPTER 3 Configuring Storage Area Network Requirements... 5 Connecting
Using Virtual Machines
Using Virtual Machines We will use VMs in CIT 130 so that you can access both a Windows 7 and a Linux machine. You will be able to access these from on and off campus (off campus access will require that
XenApp 7.7 Deployment ISO. 5 th January 2016
5 th January 2016 Document Details Document Name Author DG Version 1.0 Date 5th January 2016 Status Released Document History Date Modification Details 5/01/2016 N/A First Release Contents 1. Introduction...
Virtual Office Remote Installation Guide
Virtual Office Remote Installation Guide Table of Contents VIRTUAL OFFICE REMOTE INSTALLATION GUIDE... 3 UNIVERSAL PRINTER CONFIGURATION INSTRUCTIONS... 12 CHANGING DEFAULT PRINTERS ON LOCAL SYSTEM...
Network Shutdown Module V3 Extension of the User Manual for IBM BladeCenter architecture
Network Shutdown Module V3 Extension of the User Manual for IBM BladeCenter architecture Network Shutdown Module V3 Extension for IBM BladeCenter Architecture- 34 022 272 XU / AC Contents 1 Introduction...3
Quick Start Guide for VMware and Windows 7
PROPALMS VDI Version 2.1 Quick Start Guide for VMware and Windows 7 Rev. 1.1 Published: JULY-2011 1999-2011 Propalms Ltd. All rights reserved. The information contained in this document represents the
P4000 SAN/iQ software upgrade user guide
HP StorageWorks P4000 SAN/iQ software upgrade user guide Abstract This guide provides information about upgrading the SAN/iQ software to release 8.5 Part number: AX696-96010 Second edition: March 2010
6 Oracle Business Activity Monitoring
6 Oracle Business Activity Monitoring This chapter describes issues associated with Oracle Business Activity Monitoring (BAM). It includes the following topics: Section 6.1, "Supported Platforms" Section
XMap 7 Administration Guide. Last updated on 12/13/2009
XMap 7 Administration Guide Last updated on 12/13/2009 Contact DeLorme Professional Sales for support: 1-800-293-2389 Page 2 Table of Contents XMAP 7 ADMINISTRATION GUIDE... 1 INTRODUCTION... 5 DEPLOYING
Shearwater Research Dive Computer Software Manual
Shearwater Research Dive Computer Software Manual Revision 1.3 Table of Contents 1. Basic overview of components 2. O/S IrDA driver installation 2.1 USB IrDA installation for Windows XP Home/Pro editions
PCS Clinical Audit Tool User Guide
PCS Clinical Audit Tool User Guide Version 3.4 PART 1 INSTALLATION AND CONFIGURATION Company Contacts Sydney (Head Office) Pen Computer Systems Level 6, The Barrington 10-14 Smith St PARRAMATTA NSW 2150
MATLAB Distributed Computing Server with HPC Cluster in Microsoft Azure
MATLAB Distributed Computing Server with HPC Cluster in Microsoft Azure Introduction This article shows you how to deploy the MATLAB Distributed Computing Server (hereinafter referred to as MDCS) with
Milestone Systems Software Manager 1.5. Administrator's Manual
Milestone Systems Software Manager 1.5 Contents INTRODUCTION... 4 PREREQUISITES... 5 SUPPORTED OPERATING SYSTEMS... 5 PREREQUISITES FOR ALL REMOTE SERVERS... 5 IMPORTANT INFORMATION... 5 VERSION SPECIFIC
Upgrade Guide BES12. Version 12.1
Upgrade Guide BES12 Version 12.1 Published: 2015-02-25 SWD-20150413111718083 Contents Supported upgrade environments...4 Upgrading from BES12 version 12.0 to BES12 version 12.1...5 Preupgrade tasks...5
Configuring High Availability for VMware vcenter in RMS Distributed Setup
Configuring High Availability for VMware vcenter in RMS Distributed Setup This chapter describes the process of configuring high availability for the VMware vcenter. It provides the prerequisites and procedures
Sage Peachtree Installation Instructions
Sage Peachtree Installation Instructions Quick Tips for Network Install Use the following tips to help you install Sage Peachtree on a network: Always install Sage Peachtree FIRST on the computer that