Design of a recovery ventilation system for the Deer Island Outfall Tunnel
|
|
|
- Myles Small
- 10 years ago
- Views:
Transcription
1 Design of a recovery ventilation system for the Deer Island Outfall K.G. Wallace, Jr. Mine Ventilation Services, Inc., Fresno, California, USA I.J. Duckworth Hatch Mott MacDonald, Ltd., New York City, New York, USA ABSTRACT: This paper describes a study to establish ventilation in a sewage outfall tunnel in Boston, Massachusetts. During construction of the outfall tunnel, ventilation was achieved by means of an auxiliary forcing duct and multiple, high-pressure fans. At the end of the main tunnel are small diameter tunnels connecting to risers that each terminate at a diffuser head on the sea floor. All services, including ventilation and power were removed from the tunnel prior to the final step of removing safety plugs from the diffuser tunnels. Oxygen at the end of tunnel reduced to below 10%. The plug removal work was to be accomplished by personnel under oxygen apparatus. Work commenced in 1999 to remove the temporary plugs. After three plugs were successfully removed, a problem developed with the workers breathing apparatus resulting in fatalities. After the fatalities it was mandated by OSHA that active ventilation be re-established in the tunnel. This paper describes the options considered in establishing the tunnel ventilation system. The system chosen consisted of using an ocean barge to connect a caisson to one of the first three risers that had the temporary plug removed. Seawater was pumped out of the caisson and a ventilation pipe was installed to fit over the manhole cover on the diffuser head. The ventilation pipe was connected to an exhaust fan built on the barge. Ventilation was established on July 13, Measurements confirmed that the airflow predicted by modeling was within 3%. Acceptable oxygen levels were established in the tunnel within 16 hours and all temporary plugs were removed within five days. 1 INTRODUCTION In early 2000, Mine Ventilation Services, Inc. (MVS) was requested by the joint venture Kiewit- Atkinson-Kenny to review and recommend a ventilation system for the Deer Island Outfall. The Boston outfall is the largest ocean sewer outfall in the world. This tunneled outfall is 15 km (9.5 miles) long, and 7.3 m (24 feet) in diameter. The peak design capacity is over 55 l/s (one billion gallons per day). The diffuser system consists of risers that extend from the tunnel, about 75 m (250 ft) to the seabed. The treated sewage is then released from the riser caps as radial jets. The risers were constructed using an oil-drilling rig from the seabed down to the tunnel.. Figure 1 shows a location map for the tunnel and Figure 2 shows an approximate cross-section of the tunnel. The outfall tunnel was part of the $4 billion Boston Harbor project that included construction of a sewage treatment plant, renovation of existing sewers, tunnels for transportation of raw sewage, and drilling of the tunnel. During construction of the outfall tunnel, ventilation was achieved by means of an auxiliary forcing duct and multiple, high-pressure fans. At the end of the main tunnel are 53 short, small diameter tunnels connecting to risers that each terminate at a diffuser head on the sea floor. Boston Harbor Deer Island Massachusetts Bay Outfall Diffusers Cross-Harbor Nut Island 5 km Figure 1. Location map of the Deer Island Outfall.
2 Deer Island Treatment Plant Location of Caisson Outfall Shaft 122 m Overburden Rock Line Down Slope Sea Bottom 30 m Outfall 13,200 m 76 m Diffuser 2010 m Figure 2. Approximate cross-section of the Outfall. Figure 3 shows the connection tunnel to the main tunnel. The original design consisted of maintaining ventilation during all construction activities except the final step of removing temporary safety plugs in each short tunnel. All services, including ventilation and power were removed from the tunnel prior to the final step. Oxygen at the end of tunnel reduced to below 10%. The plug removal work was to be accomplished by personnel under oxygen bottle apparatus. Work commenced in the summer of 1999 to remove the temporary plugs. On July 12, after the removal of three plugs, the tragic deaths of two divers in the outfall tunnel brought the tunnel portion of the project to a halt. The divers, who were experienced and certified, were victims of a failure of their bottled air during the removal of the safety plugs. The U.S. Occupational Safety & Health Administration (OSHA) proposed fines of $410,900 for two dive firms, the joint venture Kiewit-Atkinson-Kenny, and the project's construction manager. The accident caused OSHA to demand that the final steps to bring the tunnel on line could be done only by ventilating the entire tunnel. Two scenarios were investigated to establish ventilation in the tunnel. MVS assisted Kiewit- Atkinson-Kenny in reviewing options for this ventilation. The options included the re-installation of an auxiliary ventilation system or the incorporation of a through-flow ventilation system. The through-flow system was selected. This system consisted of using an IB909 jack-up barge to install a caisson to one of the first three risers that had the temporary plug removed. Seawater was pumped out of the caisson and a ventilation pipe was installed to fit over the manhole cover on the diffuser Diffuser Head Sediment Riser Clay Bedrock Off take Pipe Figure 3. Detail of tunnel with riser to diffuser. head. The ventilation pipe was connected to an exhaust fan built on the IB909 barge. Ventilation was established on July 13, Measurements confirmed that the airflow predicted by modeling was within 3%. Acceptable oxygen levels were established in the tunnel within 16 hours and all temporary plugs were removed within five days. 2 DESIGN INFORMATION AND CRITERIA Sea Rock Armoring The following design information and criteria were used to analyze the two ventilation schemes: Geometry of shaft (from drawings): Depth = 128 m (420 ft) Diameter = 9.1 m (29.9 ft) Finished
3 Geometry of tunnel (from drawings): Total Length = 15,210 m (49,900 ft) Area (0 to 13,198 m [43,300 ft]) = 42.9 m 2 (462 ft 2 ) Area (13,198 [43,300 ft] to end) = Reducing to 9.3 m 2 (100 ft 2 ) Minimum air velocity criteria for tunnel: 0.51 m/s (100 fpm per contractor) 0.15 m/s (30 fpm per OSHA) Air quantity required at the end of the tunnel Duct scheme 21.7 m 3 /s (46,000 cfm based on 0.51 m/s [100 fpm] and diesel requirements) Barge scheme 14.2 m 3 /s (30,000 cfm based on reduced diesel requirements) Oxygen concentration (data provided by contractor from measurements): Surface Ambient = 21.5 % End of tunnel = 8 % Atkinson friction factors (assumed): Duct = kg/m 3 ( lbfmin 2 /ft 4 ) = kg/m 3 ( lbfmin 2 /ft 4 ) Assumed dilution of diesel exhaust: 0.06 m 3 /s/kw (100 cfm/bhp) Shock losses for bends, entry and exit: Per ASHRAE (1989) reference 3 VENTILATION STUDY Two alternatives were considered for re-establishing ventilation in the tunnel. The first was to re-install nearly 16 kilometers (9 miles) of ventilation tubing and auxiliary fans. Because power had been removed from the tunnel, staging additional fans along the tunnel was not considered to be feasible. A multiple-fan system at the portal was considered to provide for the entire duct length. Studies were also performed to determine the rate at which the ventilation tubing could be advanced and maintain acceptable oxygen rates at the work place. It was determined that this alternative would take many months to reestablish ventilation in the tunnel. The second alternative was to install a throughflow ventilation system by establishing a connection to surface close to the end of the tunnel. This connection required significant engineering to design a safe means of installing a duct from one of the risers where the temporary plug had been removed. The following sections describe the two alternatives and the ventilation analyses conducted for each case. 3.1 Auxiliary ventilation alternative This scheme proposes that cassette-type ventilation duct be advanced in the tunnel with ventilation being gradually reestablished with the duct. The main section of duct would be 1.8 m (72 inch) diameter. Based on a mass balance calculation, evaluating the amount of delivered and displaced air to give a mixed quantity along the tunnel, it was determined that a maximum advance rate of 4.6 m (15 ft) per minute could be applied while still maintaining +19.5% oxygen in the air along the tunnel. It was assumed that the entire unventilated tunnel would have an oxygen content of 8% (worst case). For this system continuous oxygen monitors would be required on all personnel working near the end of the duct. In the literature provided by the contractor, the duct manufacturer recommended a safety zone of 12 to 15 m (40 to 50 ft) ahead of the duct. This advice was supported by reference to The Committee on Industrial Ventilation (1984), which states that a blowing duct should achieve 10 % of the exit velocity at 30 duct diameters away from the discharge point. Independent calculations were conducted on the duct design offered by the duct manufacturer. In assessing this system there were three main concerns: 1 Can the duct withstand the high operating pressures predicted by the manufacturer? 2 Can the duct achieve the extremely low leakage that was used in the duct calculations? 3 The friction factor used by the manufacturer of kg/m 3 ( lbfmin 2 /ft 4 ) was very low. This could only be achieved if the duct were perfectly straight. Independent ventilation analyses indicated that at the fan pressure provided by the manufacturer (9.3 kpa [37 inch w.g.]), and with all the fans at the start of the duct, a maximum airflow of 16.5 m 3 /s (35,000 cfm) would be achieved at the end of the duct. It was determined that if the duct were allowed to deteriorate even slightly, then the face quantity would drop considerably. Under such high pressure, it would be vital that the duct be installed and maintained in excellent condition. 3.2 Through-Flow ventilation alternative This design proposed that a 1.22 m (48 inch) diameter pipe be installed at the end of the tunnel, such that it could be used to either intake air into, or exhaust air from the tunnel. Such a layout would include 128 m (420 ft) of pipe to pass air through the overlying rock and sea. This scheme would utilize a jack-up barge and ventilation riser to connect a fan to the end of the tunnel. This layout is shown in Figure 4. For this scheme the airflow would take the following route: Enter through the effluent shaft (on Deer Island). Pass along approximately 13,198 m (43,300 ft) of tunnel. Pass through the diffuser tunnel area to diffuser #3 (2,010 m [6,600 ft] long, tunnel reduces to approximately 2.4 m [8 ft] diameter at diffuser #3).
4 Rock Sea Level Heavy-Duty Caisson Diffuser Head Isolation Plug 0.76 m Fiberglass Riser To 1.22 m Ventilation Duct Abrupt transition from the tunnel into a horizontal, 0.76 m (2.5 ft) diameter fiberglass pipe. Swept 90 bend followed by 69 m (225 ft) long, 0.76 m (2.5 ft) diameter fiberglass pipe to the sea bed. Transition from smaller fiberglass pipe to 1.22 m steel ventilation duct (1.22 m [48 inch] diameter). Pass through steel ventilation duct to the barge (52 m [170 ft] vertical), then through a mitered bend to the fan. Airflow Sea Sea Floor Exhaust Fan w/ Silencers On Barge Figure 4. Detail showing through flow ventilation scheme. The ventilation requirement for the tunnel was reduced for the barge scheme due to less diesel and fewer people (no duct installation). The airflow requirement was determined to be 14.2 m 3 /s (30,000 cfm), based on the diesel equipment, eight people, and a minimum tunnel velocity of 0.15 m/s (30 fpm as dictated by OSHA). A ventilation network was established for this configuration (using the VnetPC 2000 ventilation simulation program). As expected, the model showed that the frictional pressure losses (and subsequent fan power requirements) to move the air through the tunnel and shaft sections would be low. The majority of the fan pressure would be utilized in moving the air through the smaller pipes, which connect the main tunnel to the barge (due to losses at the transitions, bends, and along the pipes themselves). The modeling assumed that the fan(s) will be placed on the barge and exhaust air from the tunnel and that the fiberglass and steel pipes will be smooth-walled. The following fan operating requirements were predicted: 17.2 m 3 /s (36,500 cfm increased to account for leakage). 3,064 Pa (12.3 inch w.g.) fan total pressure. This operating point was for two Joy Model fans placed in series (or a single two-stage fan) at blade setting #2. Approximately the same operating characteristics were predicted if the fans were placed on a forcing system. This would push the air from the barge region through the tunnel, to exhaust via the effluent shaft. When considering the option of either exhausting or intaking from the barge, the following issues were taken into account: An exhaust system would ensure that the fresh air base is expanded from the shaft towards the diffuser area, which is the direction of re-entry for personnel. It will be easier to monitor and control the discharge of the low oxygen tunnel air if an exhaust system is used. The region immediately around the fan discharge can be cordoned-off, and sampling can be conducted while the air is in the ventilation duct. If there are any leakage points in the fiberglass or steel pipes, and there is a build-up of water, then the exhaust system would draw more water into the pipes due to the system being on negative pressure. A forcing system will tend to help prevent the ingress of water or gases. However, since a caisson system is proposed, water leakage should not be a critical issue. 3.3 Selected alternative The exhausting through-flow alternative was selected for the recovery ventilation system in the tunnel. The main reasons for this decision were: The ducting would take a significant period of time to procure and install. During the period of installation and recovery, workers would still be placed in a potentially hazardous environment near the duct discharge. There was uncertainty in the ability of the auxiliary duct system to provide sufficient airflow over the entire length of the tunnel. In early July 2000, the IB909 jack-up barge was positioned over the third diffuser head. The sequence required to open the diffuser was as follows: 1 Divers were sent to the diffuser head to remove loose debris and loosen the bolts on the manhole cover on top of the diffuser.
5 2 The caisson was positioned over the diffuser head. The caisson was fitted with an inflatable gasket to minimize water inflow into the pipe. 3 A pump was positioned into the caisson and the water pumped out. 4 The ventilation pipe was installed in the caisson. 5 A crane with a grappling hook was positioned over the caisson and used to remove the manhole cover. 6 Once the manhole cover was removed, the fan system was connected to the ventilation pipe. Figure 5 shows the fan system on the barge. A heavy plug was suspended out of the airstream above the diffuser opening such that it could be dropped into the manhole upon loss of caisson integrity. In the event of rough seas, collision with another vessel, or excessive leakage into the tunnel, the plug would be lowered by the crane and inserted into the manhole cover. If necessary the caisson and ventilation pipe could be removed and replaced at a later date. 4 INSTALLATION OF VENTILATION SYSTEM On July 13, 2000 the final connection was made to the fan (two-stage) on the IB909 jack-up barge. The fan was commissioned and a series of measurements were performed to determine the airflow exhausting the Deer Island Outfall. The measurements involved determining the fan total exhaust pressure, traversing the duct upstream of the silencers to calculate air velocity, measuring the dry bulb temperature, relative humidity and barometric pressure of the air in the duct, taking oxygen readings at the fan exhaust, and recording the fan amperage. The duct was traversed in two directions and the average velocity readings were recorded. These measurements were taken two times and the average used in the calculation of airflow exhausting through the fan. The exhaust duct at the fan was 0.97 m (38 in.) in diameter. The measured data was as follows: Average velocity pressure (two traverses): kpa (1.266 in. w.g.) Fan total pressure: 3.21 kpa ( in. w.g.) measured upstream of silencers. Air exhaust dry bulb temperature: 8.5 C (47.4 F). Air exhaust relative humidity: 98 % Surface barometric pressure: kpa (29.90 in. Hg.). Fan amperage meter: 154 Amps Fan voltage: 440 V (assumed, not measured) Exhaust oxygen spot reading: < 12% O 2 (sensor withdrawn because of high moisture content of the air). Figure 5. Fan on IB909 jack-up barge. From these data the following parameters were calculated: Air density exhausting duct: 1.21 kg/m 3 ( lbm/ft 3 ). Air velocity in duct: 22.8 m/s (4,494 ft/min) Airflow in duct: 16.7 m 3 /s (35,400 cfm) Fan efficiency: 59 % Motor input power: 138 hp (103 kw) The computer simulations predicted the airflow through the tunnel at 17.2 m 3 /s (36,500 cfm). The actual airflow was slightly less than this value by 3%. This result proved the benefit of modeling the system prior to installation. It also showed that there were minimal obstructions in the ventilation pipe (e.g. flooding of the elbow, etc.) that were not accounted for in the ventilation model. The predicted fan operating pressure was within 4% of actual. The results indicate that the ventilation models were interpreting and representing the actual fan operating characteristic curve correctly, and that the manufacturers provided curves closely fit actual performance. It was noted that there was some air leakage around the surface T, plug, connections and probably where the ventilation tube connects to the diffuser. However, no obvious large leakage points were noted and it was difficult to determine if significant airflow was passing through the annulus between the ventilation pipe and the caisson. Another factor influencing the airflow rate was a large quantity of water exhausting the fan. This water is likely coming from the tunnel horizon. From the air quality measurements it was determined that a significant portion of the exhaust air must have originated from the tunnel since the oxygen levels at the fan exhaust were low (below 12%).
6 The low oxygen levels indicated an unacceptable tunnel environment for unprotected workers. Providing over 14.2 m 3 /s (30,000 cfm) to the tunnel over a 12 to 13 hour time period restored normal oxygen levels for the entire tunnel length (to Diffuser #3). Re-entry to the tunnel was achieved on July 15, Work commenced and all remaining tunnel plugs were removed in five days. This was five weeks ahead of schedule. The tunnel was commissioned for use in September. The total cost of the recovery ventilation system was approximately $15 million. While this value seems high, it was considered cost effective when factoring in the lengthy delay associated with the commissioning the auxiliary ventilation alternative. 5 SUMMARY REFERENCES ASHRAE Handbook, 1989, Fundamentals, I-P Edition, Published by the American Society of Heating, Refrigeration and Air Conditioning, Inc., pp Ben C. Gerwick, Inc., Gerwick News List, October, Committee on Industrial Ventilation, 1984, Industrial Ventilation, 18 th Edition, A Manual of Recommended Practice, Published by the American Conference of Government Industrial Hygienists. Effluent Outfall Ventilation, 2001, MWRA, Public Affairs, Charlestown Navy Yard, 100 First Ave., Boston, MA 02129, Nova Award Nomination 35, Massachusetts Water Recourses Authority. OSHA Regional News Release, U.S. Department of Labor, Office of Public Affairs, Region 1 News Release: BOS , January 19, This paper describes an innovative ventilation system for rapid recovery of a long sub-aqueous tunnel. The system was safely installed and the airflows predicted through the tunnel were within 3% of the actual airflow. The project represented collaboration between contractor, consultant, local authorities, federal authorities and the unions. Future outfall projects may consider this type of active ventilation system when commissioning similar tunnels.
R. Ruckman & B. Prosser Mine Ventilation Services, Inc., Clovis, California USA
13 th United States/North American Mine Ventilation Symposium, 2010 Hardcastle & McKinnon (Eds.) 2010, MIRARCO - Mining Innovation Integrating ventilation monitoring sensor data with ventilation computer
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs
Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs Fan Performance (Paper I.D. 021) Mark Stevens Air Movement and Control Association International Abstract
Basic Selection & Proper Application of Overhead Air Distribution Devices
Basic Selection & Proper Application of Overhead Air Distribution Devices GRD Selection & Application Terms Selection Throw Sound Installation Variations affect Performance Inlet Effects Basics Return
SAM HOUSTON STATE UNIVERSITY
PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the
Specifications for Residential Property Owners Connection to New Public Sewer
Specifications for Residential Property Owners Connection to New Public Sewer Spalding Tract property owners are required to connect to the community sewer system when construction is complete and the
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
LS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
Fan Applications & System Guide
Fan Applications & System Guide Airflow for general ventilation can be calculated by; Area Method Air Change Method Occupancy Method Ventilation Calculation Methods Area Method Derives the ventilation
AABC Specifications for Testing and Balancing HVAC Systems
AABC Specifications for Testing and Balancing HVAC Systems The Associated Air Balance Council (AABC) Total System Balancing Specifications for HVAC Testing, Balancing and Performance Verification TOTAL
CO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
Chapter 9 Sanitary Sewers
Chapter 9 Sanitary Sewers S:/Engineering/Design Standards/Chapter 9 12/29/2014 Section 9.1 Topic General Requirements Chapter 9 Sanitary Sewers Page 9-1 9.2 Plan Submittals 9-1 9.3 Determination of Flow
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal
Technical Bulletin By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal SUMMARY Refrigeration air coolers (evaporators)
Exhaust Calculation Booklet
Exhaust Calculation Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: [email protected] ADC Part No. 450450 Exhaust
Confined Space Air Monitoring
November 2008 Vol. 26. No. 3 Confined Space Air Monitoring Scott Shinn, C.I.H. Scott Shinn is a Certified Industrial Hygienist with 3M OH&ESD Technical Service and Regulatory Affairs. Summary Over the
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.
Thermo 1 (MEP 261) Thermodynamics An Engineering Approach Yunus A. Cengel & Michael A. Boles 7 th Edition, McGraw-Hill Companies, ISBN-978-0-07-352932-5, 2008 Sheet 5:Chapter 5 5 1C Name four physical
PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE
PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE APPLICATION NOTE TI-138 TSI s IAQ-CALC TM Indoor Air Quality Meter and TH-CALC TM Thermohygrometer calculate Percent Outdoor Air (%OA). In order to take
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
Section 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
plenum slot diffusers
light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4
HVAC Basic Science - System Capacity
HVAC Basic Science - System Capacity Btu/hour, btu/h, b/h, btuh. btu?? 1 MBH = 1000 btu/hour 1 KBH = 1000 btu/hour 1 ton of cooling= 12,000 btu/hour 1 watt = 3.414 btu/hour 1 kilowatt = 1000 watts = 3,414
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
ANSI/AHRI Standard 880 (I-P) with Addendum 1. 2011 Standard for Performance Rating of Air Terminals
ANSI/AHRI Standard 880 (I-P) with Addendum 1 2011 Standard for Performance Rating of Air Terminals Approved by ANSI on October 27, 2011 WITH ADDENDUM 1, PERFORMANCE RATING OF AIR TERMILS June 2012 Note:
Mechanical Heating Ventilation and Air Conditioning Ductwork and Duct Accessories
Basis of Design This section applies to the design and installation of ductwork, air terminal boxes, air outlets and inlets, volume dampers, pressure relief dampers, smoke/fire dampers, and smoke/fire
Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011
Fans and Air Handling Units Will Rea and Paul Pilutti February 16 th, 2011 HTS Lunch and Learns Available Online Visit www.htseng.com Engineering Tools Resource Center Contents Fans Fan Curves Fan Laws
ENGINEERING DATA. Fan Performance Troubleshooting Guide
Information and Recommendations for the Engineer ENGINEERING DATA Aerovent TC Ventco Fiber-Aire Twin City Fan & Blower TC Axial Clarage Fan Performance Troubleshooting Guide ED- Introduction Trying to
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
HVAC air curtains. Type InduAir
Air Conditioning Cooling Heating Ventilation HVAC air curtains Type InduAir The Energy Saving air curtain for Industrial Applications InduAir The solid, self-supporting housing of the energy saving air
HVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery
University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery Yellow Alert for Mayflower Residence hall Peak at 31.5 feet Power Plant floods from steam tunnel and shuts down 1993 Flood
How To Use A Water Source Heat Pump
Geothermal Energy Using Water-Source Heat Pumps By VIRSTAR Corporation Geothermal Expertise Since 1978 All information contained herein is the exclusive property of VIRSTAR Corporation, all rights reserved.
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29
_02 A centrifugal with a 12 in. diameter impeller requires a power input of 60 hp when the flowrate is 3200 gpm against a 60 ft head. The impeller is changed to one with a 10 in. diameter. Determine the
KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority
Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority Abstract The United States Virgin Islands Waste Management Authority
AMD-33 Air Measuring Station with VCD-33 Control Damper
Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION
SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing
Design of Closed-loop Fumigation Systems for Grain Storage Structures
Oklahoma Cooperative Extension Service BAE-1111 Design of Closed-loop Fumigation Systems for Grain Storage Structures Carol Jones Assistant Professor, Stored Products Engineering James Hardin Research
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD 21.01 SCOPE: It is the intent of the Specification to define the approved methods and materials
VAV Laboratory Room Airflow The Lowdown on Turndown
Technology Report March, 2003 VAV Laboratory The Lowdown on Turndown Turndown comparison of these two turndown ratios. Note the small actual airflow difference between them. control ranges are normally
SECTION 02401 SHEETING, SHORING AND BRACING
SECTION 02401 SHEETING, SHORING AND BRACING This section should be edited to reflect soil conditions specific to the project site and the recommendations of a Geotechnical Engineer licensed in the State
SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER
Village of Shorewood, Wisconsin SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Prepared By: Thomas A. Zoulek, P.E., LEED A.P. Vice President Mid City Plumbing & Heating
Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards
Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards American Industrial Hygiene Association Developed by the AIHA Confined Spaces Committee Approved by the AIHA Board of Directors
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains
KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005
KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO SAUDI STANDARD DRAFT No. 3457/2005 NON-DUCTED AIR CONDITIONERS AND HEAT PUMPS TESTING AND RATING PERFORMANCE This standard is developed
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
IDES-EDU. Educational Package Ventilation. Lecture 8: Sizing mechanical ventilation systems IEE/09/631/SI2.558225 28.10.2011.
Introduction Educational Package Ventilation Lecture 8: Sizing mechanical ventilation systems IEE/09/631/SI2.558225 28.10.2011 Air Flow : Relation between air flow, air speed and duct section Ventilation
2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT
2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT Open channel flow is defined as flow in any channel where the liquid flows with a free surface. Open channel flow is not under pressure; gravity is the
DRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions M. Liu, Y. Zhu, D. E. Claridge Energy Systems Laboratory Texas A&M University Ed. White Energy Management Operation
Using Portable Spot Air Conditioners in Industrial Applications
Using Portable Spot Air Conditioners in Industrial Applications Cooling People, Processes and Equipment In today s highly competitive manufacturing sector, companies are constantly looking for new ways
Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle
INL/CON-05-00740 PREPRINT Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle Geothermal Resources Council Annual Meeting Greg Mines October 2005 This is a preprint of a paper intended for publication
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
Performance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling
Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling Panu Mustakallio and Risto Kosonen Halton Oy, Haltonintie 1-3, 47400 Kausala, Finland E-mail: [email protected]
March 2006 DIVISION 3 - CW 2140-R3 TABLE OF CONTENTS
March 2006 CW 2140 - SEWER AND MANHOLE CLEANING TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Constructions... 1 3. CONSTRUCTION METHODS... 1 3.1 High
Pump Formulas Imperial and SI Units
Pump Formulas Imperial and Pressure to Head H = head, ft P = pressure, psi H = head, m P = pressure, bar Mass Flow to Volumetric Flow ṁ = mass flow, lbm/h ρ = fluid density, lbm/ft 3 ṁ = mass flow, kg/h
CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General
General All sanitary sewers, manholes and force mains shall be acceptance tested, as hereinafter specified in the presence of a City representative. Acceptance testing shall be performed after backfilling
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses
A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses Robert L Crosby Jr, Biorealis Systems, Inc. Abstract: Bristol Bay Housing Authority (BBHA) currently
Treatment Practice for Controlling Water Damage in the Annular Space of Shaft Freezing Hole
An Interdisciplinary Response to Mine Water Challenges - Sui, Sun & Wang (eds) 2014 China University of Mining and Technology Press, Xuzhou, ISBN 978-7-5646-2437-8 Treatment Practice for Controlling Water
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Design Considerations for Underfloor Heating Systems. What is Frost Heave Protection?
Design Considerations for Underfloor Heating Systems Daniel Dettmers Industrial Refrigeration Consortium University of Wisconsin-Madison What is Frost Heave Protection? As soil drops below freezing, moisture
Flexibility, Efficiency In San Antonio Arena
2005, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Reprinted by permission from ASHRAE Journal, (Vol. 47, No. 9, September 2005). This article may not
ELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
Ventilation Standard For Health Care Facilities
The following article was published in ASHRAE Journal, October 2008. Copyright 2008 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis
Components HVAC General System Selection Life Cycle Cost Analysis Outdoor Air Design Values Indoor Air Design Values Outdoor Air Ventilation Welding Ventilation Temperature Control Systems Ductwork HVAC
SANITARY SEWER BACKUP. Causes & Prevention
SANITARY SEWER BACKUP Causes & Prevention A. PURPOSE The purpose of this publication is twofold: 1. It provides homeowners with basic information on the causes of sanitary sewer backups. 2. It provides
Balancing of a water and air system
Balancing of a water and air system Roger D. Holder MSME A well performed testing, adjusting and balancing (TAB) of a HVAC system is essential for the proper performance of that system and can enhance
Refrigeration Installation 101
Refrigeration Installation 101 Hundreds of Installations Refrigerated Cases 2 Compressor Racks 3 Condensing Units 4 Walk-in Boxes 5 Some were done very well 6 Some had some issues... 7 8 Some seemingly
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
Overview of the OSHA Confined Spaces in Construction Final Rule
Labor, Safety & Health Policy National Association of Home Builders Overview of the OSHA Confined Spaces in Construction Final Rule On May 4, 2015 the U.S. Occupational Safety and Health Administration
85 F 80 F 50% 75 F 70 F 73.0/61.8 45 F 10% Figure 1
Feb. 07 INTRODUCTION: Wrap around heat pipes are air-to-air heat exchangers that are installed in the airstream upstream and downstream of a cooling coil to deliberately reduce the Sensible Heat Ratio
Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
CHAPTER 4 VENTILATION
CHAPTER 4 VENTILATION SECTION 401 GENERAL 401.1 Scope. This chapter, in conjunction with the building code, shall govern the ventilation of spaces within a building intended to be occupied. Mechanical
Module 9: Basics of Pumps and Hydraulics Instructor Guide
Module 9: Basics of Pumps and Hydraulics Instructor Guide Activities for Unit 1 Basic Hydraulics Activity 1.1: Convert 45 psi to feet of head. 45 psis x 1 ft. = 103.8 ft 0.433 psi Activity 1.2: Determine
AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.
Application and esign Thermal ispersion Air Measuring Station with VC-23 Control amper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.
SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings
San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION
ITEM 866 SEWER MAIN TELEVISION INSPECTION 866.1 DESCRIPTION: The Contractor shall furnish all labor, materials, equipment, and incidentals to provide the televising and a NASSCO-(PACP) standard video,
Pool Dehumidification Basics
Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing
How to Measure HVAC System Airflow
How to Measure HVAC System Airflow About National Comfort Institute National Comfort Institute is an international training Since our and beginning development in 1994 company we have trained with and
How To Clean Water From An Ammonia Refrigeration System
Water Contamination and Water Removal in Industrial Ammonia Refrigeration Systems By Ray Ficker, PE Effects of Water Contamination Water contamination in an industrial ammonia refrigeration system can
The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL
The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL Technical Article April 2013 The ASHRAE HQ Building Can
Emergency Spillways (Sediment basins)
Emergency Spillways (Sediment basins) DRAINAGE CONTROL TECHNIQUE Low Gradient Velocity Control Short-Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1] [1]
FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.
FLUID MECHANICS TUTORIAL No.7 FLUID FORCES When you have completed this tutorial you should be able to Solve forces due to pressure difference. Solve problems due to momentum changes. Solve problems involving
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals
Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals HVAC PROGRAMS The school s Heating, Ventilation, and Air Conditioning Programs provide training for entry level employment
Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE <[email protected]
Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000