ATT-TP SSTC: SSIM:: High Capacity Digital Testing
|
|
|
- Lynn Jacobs
- 10 years ago
- Views:
Transcription
1 ATT-TP SSTC: SSIM:: High Capacity Digital Testing To: ATT technicians that test Hi-Cap DS1 circuits Effective Date: June, 2001 Issue Date: Expires On: Related Documents: Canceled Documents: Issuing Department: Business Unit: N/A TR Report Number 25 - Test Patterns for DS1 Circuits, AM Ameritech High Capacity Digital Service Provisioning Guidelines, L PB/NB Standards (Tech Pub), ATT-TELCO Job Aid -HDSL4 Deployed using ADC Soneplex Loop Extender Chassis, Tech Support Bulletin Tab 6-67 AM-SR-NCS , AM , TP High Capacity Digital Service (1.544 Mb/s) Requirements and Transmission Limits(ATT West) Network Services Network Points Of Contact: Denise Lopez, SSTC Support Staff, (913) Pat Wilke, SSTC Support Staff, ( ) Author(s): Pat Wilke i
2 Table Of Contents General 1. REASON FOR REISSUE 1 2. IDENTIFYING HICAP (T1) SERVICES COMMON LANGUAGE CIRCUIT IDENTIFICATION (CLCI) COMMON LANGUAGE FACILITY IDENTIFICATION (CLFI) 3 3. IDENTIFYING STANDARD (NON HDSL) VS. HDSL SPANS STANDARD SPAN IDENTIFICATION ATT Midwest, ATT Southwest and ATT SNET ATT West Region HDSL SPAN IDENTIFICATION ATT Midwest, ATT Southwest and ATT SNET ATT West 6 4. IDENTIFYING LINE CODE (AMI VS. B8ZS),FRAMING, AND IMPEDANCE NCI and NC CODES TO IDENTIFY LINE CODE (AMI VS. B8ZS),FRAMING, 8 AND IMPEDANCE 4.2. FACILITY TYPE AND LINE CODE FOR USE WITH CLFI CODE 9 5. TEST PATTERNS, DEFINITIONS AND USAGE (SEE ATTACHMENT 1 FOR TEST PARAMETERS) DB LOSS TEST (USED ON STANDARD SPANS ONLY) CURRENT MEASUREMENT (also known as Milliamp test) USED ON 10 STANDARD SPANS ONLY FROM THE NETWORK INTERFACE/SMARTJACK 5.3. QRSS (Quasi Random Signal Sequence) TEST PATTERN in 8 PATTERN (also known as 1:7) in 24 PATTERN ALL ONES ALL ZEROS TEST PATTERN BRIDGED TAP TEST NON-STANDARD TESTS - BILLABLE TESTS Attachment 1 - DS1 SERVICE MB/S TESTING PROCEDURES, PROVISIONING AND MAINTENANCE Attachment 2 - Acronyms Attachment 3 - HDSL TERMINOLOGY AND DEFINITIONS Attachment 4 - HDSL Remote Unit Problems 35 ii
3 General Purpose This document replaces regional documents for 13 state conformity. Special Services Test Centers Management requested a team to update test parameters to include High-Bit-Rate Digital Subscriber Line (HDSL). This document defines basic stress testing functions for DS1 services and testing parameters to enable the Special Services Test Center (SSTC) tester and Special Services Installation & Maintenance (SSIM) technician to determine which tests will be run for acceptance of new DS1 circuits. Stress tests are used in several ways: Pre-service testing to ensure that a DS1 facility meets objectives for characteristic parameters before it is turned up for service Trouble verification in response to a trouble report or indication Sectionalizing confirmed faults Verification of repair The stress tests performed that pertain to installation and maintenance stress testing use specific bit patterns for AMI and B8ZS line codes. These tests are time dependent with stipulated performance requirements of zero errors. The testing functions described in Attachment 1 - Section 6, should be used for installation and maintenance of all Mb/s, High-Capacity Digital Services. Scope An installation test on a typical circuit will require the use of these stress tests to ensure proper turn-up. For maintenance, the choice of a useful sequence must be made by the tester and is dependent upon the trouble reported or an indication of what the trouble may be. Decision logic for trouble isolation is not defined to allow the tester to choose the next function to be performed based on previous results. Trouble isolation logic or sequence may vary by area; therefore, local methods and procedures should be used to perform trouble isolation and repair functions. The functions included are intended for use in providing testing support for installation and maintenance stress tests of DS1 services. Stress tests are applied to a circuit to identify or confirm that a circuit or facility is within acceptable test parameters. Circuits are stressed by applying a maximum or minimum ones-density pattern, that is, all-ones signal versus a 1-in-8 signal(b8zs)or 3 in 24(AMI). 1. REASON FOR REISSUE Issue 12: 8/18/06 PMW - Replace Attachments 1-4 in document. Update SBC verbiage to ATT. Issue 11: 05/06/03 PMW - Attachment 1, Section 3.0 Add H4TU-C Soneplex Tech Support Bulletin information- Midwest Only. 1
4 Issue 10: 01/07/03 PMW Change AIT to SBC Midwest, SWBT to SBC Southwest, PB/NB to SBC West and SNET to SBC SNET to show correct corporate identity. Add Special Note to Attachment 1 to reflect that Litespan changes the line code default on HDSL2 units from B8ZS to AMI. The system must be reprovisioned to return the line code to B8ZS after insertion of the card. Issue 9: 10/10/02 PMW Show PB/NB Tech Pub L in Related Documents. Add PB/NB verbiage to section 5.9. Add to Appendix 1 Section 2, Boot Process for DS1 card in Litespan system, SBC Midwest only. Update Section 2.2 in the appendix to show CART is the preferred method to populate OSSCN screen in WFA/C. Update Section 5.1 to add CART and Remote Testing. Issue 8: 06/15/02 PMW Add HDSL4 info with 2 regenerators, revise HDSL test tables to show reading taken via software and assumes sync between HDSL units. Add note to signal level for HDSL. Issue 7 :04/22/02 PMW Add HDSL4 information, revise OSSCN. Issue 6: 03/25/02 PMW Revise Section Span Identification Table updated to reflect 4 characters in WFA. Tables noted that HDSL4 is under development. Issue 5: 03/05/02 PMW Add NC codes, change Table 2 to add note for HDSL2 units that do not have line code options. Issue 4: 01/23/02 PMW - Note added to sections for standard span current measurement test when fiber exists to the customer premises. Update special note in Section 4.0. Issue 3: 8/20/01 PMW - Update General section in Attachment 1 to give SSTC option of phoning CO to verify mux options. Update section 4.0 to clarify this test is not used on B8ZS circuits. Add SSTC can call to verify mux options. Issue 2: 6/2001 ATAS information added, change title on Table 8, add verbiage to clarify B8ZS line code verification in Section 4. Add Attachment 3 - Terminology and Definitions, and Attachment 4, HDSL Remote Unit Problems. Merge framing and line code section and add impedance. Delete section to verify protect switch path. 2. IDENTIFYING HICAP (T1) SERVICES 2.1. COMMON LANGUAGE CIRCUIT IDENTIFICATION (CLCI) The Common Language Circuit Identification (CLCI) is located in Work Force Administration / Control (WFA/C) on screens that contain a circuit number. The circuit number is also found on Work Order Record Detail (WORD) documents with serial number circuit identifications. Example: CKT S /HCGS/ /LB The CLCI is HCGS. The first two characters identify the type of service. Below is a list of T1 CLCIs. HC DH 2
5 HX or FL IP SY YB UM 2.2. COMMON LANGUAGE FACILITY IDENTIFICATION (CLFI) The Common Language Facility Identification (CLFI) is located on WFA/C screens that carry a facility type circuit number. Example: C 101/T1ZF /CHCGILLADC0/CHCGILTFH01 T1 is the facility type to denote HiCap. 3. IDENTIFYING STANDARD (NON HDSL) VS. HDSL SPANS Standard spans do not utilize HDSL technology. Span identification is region specific STANDARD SPAN IDENTIFICATION ATT Midwest, ATT Southwest and ATT SNET Span type identification is determined from the circuit design on the WORD document. The span type is determined from the customer premises Network Interface (NI) to the central office serving the customer premises. Example: FH101 CABLE L1 T1S 9 FH101 CABLE T1S is a standard(non-hdsl) span. 3
6 Below is a portion of a WORD document containing an example of a standard span utilizing Intelligent Office Repeaters(IOR). Note the pair separation. W T1R3LU02 IP Example of IOR with options. S2=ALL SEGMENTS OUT(0. 0DB),S3=-130V,S4=POSITI ON 0,S9=ENABLE,LOOPABLE,LOOPBACK ADDRESS CODE= #1,(AM )S10A& S10B=AIS MDF 01/F01/N127 ACD TRDF 01/F10 MILWWI45 47 CABLE AZ Pair separation indicates standard span. 47 CABLE ZA W L1 T1S 4 47 CABLE AZ 47 CABLE ZA Below is a portion of a WORD document of a standard span utilizing Intelligent Line Repeaters (ILR) MILWWIR0236 BLMD RD 880'WOF CALHOUN RD RT ADDR MILWWIR CASE=21 SLOT=21 T1R1B10C PE MILWWIR0236 EXC XT Note pair separation in standard spans. EXC XR ATT West Region Pair separation also identifies Standard span types in ATT West. See ATT Midwest, ATT SNET and ATT Southwest example above. 4
7 3.2. HDSL SPAN IDENTIFICATION Span type identification is determined from circuit design on the WORD document. The span type is determined from the customer premises Network Interface (NI) to the central office serving the customer premises. Example: 1784A CABLE Note: HDSL does not require pair separation. L01 T1SH 2 ( SH indicates ADC (Pairgain) with no regenerator.) 1784A CABLE ATT Midwest, ATT Southwest and ATT SNET Following is a table of span types. 5
8 T1S T1SH Table 1: Span Types ATT Midwest, ATT Southwest and ATT SNET Standard span no HDSL ADC(Pairgain) HDSL no regenerators T1SHD Note: WFA may populate only 4 characters and may be seen as T1SD ADC(Pairgain) HDSL - 1 regenerator T1SHT Note: WFA may populate only 4 characters and may be seen as T1ST ADC(Pairgain) HDSL - 2 regenerators T1H T1HD T1HT T1H2 T1H4 T1H4D Note:WFA may populate only 4 characters and this may be seen as T14D. Adtran HDSL - No regenerators Adtran HDSL - 1 regenerator Adtran HDSL - 2 regenerators Adtran HDSL2 (2 wire HDSL - no regenerators used with this product) Adtran HDSL4 Adtran HDSL4-1 regenerator T1H4T Adtran HDSL4-2 regenerators ATT West Equipment type defines the span type in ATT West. The following function codes are to be used on HiCap designs. The chart below shows all combinations of function codes old and new for office repeaters. These function codes must be used in pairs; i.e., the CO unit must match the Network Channel Terminating Equipment (NCTE)unit. Please note that the new PAIRGAIN unit now has 2 function codes, one for AMI and one for B8ZS. In the near future, the distinction will be made to the Kentrox and ADTRAN. Due to the massive PROCDS models involved, it will be done when the PROCDS enhancement that is on request to Telcordia is available. The old PAIRGAIN unit is still usable for redesigns without changing the plug that is place. NOTE: Pairgain was acquired by ADC. Unit may have either name. 6
9 Table 2: ATT West Equipment Codes Usage Co Repeater NCTE at Customer End T1 (non HDSL) KENTORB TSNPSC2ANN T1 (non HDSL) Teltrend ORBSTT TSNPSC2ANN T1 (non HDSL) Westell ORBSTW TSNPSC2ANN HDSL2 AMI ADTRAN (NEW) HC6AANNNNN2N HR6NNNN2AN HDSL2 B8ZS ADTRAN (NEW) HC6ABNNNNN2N HR6NNNN2AN HDSL using ADTRAN TRHCZE0AFAN +F44HA HDSL AMI using PAIRGAIN HDPA9AUHNNNN +F44HP HDSL B8ZS using PAIRGAIN HDPA9BUHNNNN +F44HP HDSL PAIRGAIN (old, AMI or B8ZS) TRHCBBNNNMD +F44HP Limited HDSL / HDSL2 usage (6 max) mountings: ADTRAN HDSL PAIRGAIN HDSL ADTRAN HDSL2 AMI ADTRAN HDSL2 B8ZS Note:Adtran HDSL2 unit may be HDSLPB2 - without an A or B modifier depending on if the card has a line code option. HDSLPB HDSLPBP HDSLPB2A HDSLPB2B +F44HA +F44HP HR6NNNN2AN HR6NNNN2AN ADTRAN HDSL4 220, 3192, DDM+ Shelf Soneplex Shelf TA 3000 Shelf Note: xxx will vary depending on line code, bit rate and span power. HU4SCxxxx SNRZNNxxxx HT13Dxxxxxxx HU4SRNxxx 4. IDENTIFYING LINE CODE (AMI VS. B8ZS),FRAMING, AND IMPEDANCE 7
10 4.1. NCI and NC CODES TO IDENTIFY LINE CODE (AMI VS. B8ZS),FRAMING, AND IMPEDANCE Table 3, below carries select NC codes. The fourth character is not included in the chart and is represented by a dash(-). NOTE: For more information see Telcordia Technologies Practice BR HC-- HCD- HCE- HCF- HCG- Table 3: Select NC Codes AMI - SF ANSI AMI - ESF ANSI B8ZS - ESF Non ANSI AMI - ESF Non ANSI B8ZS - ESF HCZ- B8ZS - SF NCI codes are used to identify AMI vs. B8ZS on circuits with a serial number circuit ID. Example NCI: 04DU9/1SN/ The NCI code is composed of 12 characters. The first 2 characters denote the number of wires. In the example above, it is 4 wires. Character 3 and 4 is the protocol code. DU is a digital access interface. Character 5 denotes the impedance. A 5 in this field denotes 135#, a 9 denotes 100#. The first delimiter is a slash(/). Characters 7, 8 and 9 are the option codes which will determine AMI vs. B8ZS. Some common option codes are listed below. Option Codes Table 4: Line Coding and Framing Utilizing NCI Codes Line code and framing 1S or 1SN (N denotes no line power) D or DN 1K or 1KN B or BN B8ZS - ESF B8ZS - SF AMI - ESF AMI - SF 8
11 NOTE: For more information see Telcordia Technologies Practice BR FACILITY TYPE AND LINE CODE FOR USE WITH CLFI CODE AMI or B8ZS can be identified from the circuit number, when the CLFI code is used. The facility type will have a Z embedded in the facility type for B8ZS operation. Example: 101 /T1ZF/CHCGILLADC0/CHCGILTFH01 (B8ZS) The lack of a Z in the facility type below indicates the circuit is AMI. Example:401 /T1/LVPKILRNDC0/RCFRILADW01 (AMI) The facility type indicates the framing ordered by the customer when CLFI circuit identification is used. An F in the facility type denotes ESF. Lack of the F denotes Superframe or D4 framing. Example: 101 /T1ZF /CHCGILCLDC3/CHCGILYRH05 EXTENDED SUPERFRAME- B8ZS 401 /T1 /LVPKILRNDC0/RCFRILADW01 D4 FRAMING (Superframe)- AMI 5. TEST PATTERNS, DEFINITIONS AND USAGE (SEE ATTACHMENT 1 FOR TEST PARAMETERS) 9
12 Errored Second Table 5: Definitions Any one-second period containing one or more bit errors. AMI Alternate Mark Inversion is a pseudo-ternary signal conveying binary digits in which successive "ones" (marks, pulses) are of alternating, positive (+) and negative (-) polarity, equal in amplitude and in which a "zero" (space, no pulse) is of zero amplitude. B8ZS Bipolar with 8-Zero Substitution is a code in which eight consecutive "zeros" are replaced with a sequence if the preceding pulse was a positive (+) and with the sequence if the preceding pulse was a negative (-) pulse; zero represents no pulse. Straight-away A test configuration where the testing is performed using BERT test sets at both ends of the circuit or portion of circuit to be tested DB LOSS TEST (USED ON STANDARD SPANS ONLY) DB loss tests are only required on service orders with non-hdsl copper facilities and on maintenance cases where non-hdsl copper facilities have been replaced. To test the end section loss, an un-framed "all ones" 1.544Mb DS1 signal is sent (by the Central Office Technician, SSIM through CART, or the SSTC remote access) from the serving CO and measured at the customer's Service Interface by the outside Technician. An un-framed all ones signal is used because it leaves the last repeater at the required 772 KHz at 0 db toward the customer.(loopbacks may be used by the outside field technician.) Step 1 Send an un-framed "all ones" DS1 signal toward the customer location using a DS1 Bit Error Rate Test Set (BERT). The Central Office (CO) technician will do this from the local Serving Office DSX-1 frame. The Special Services Test Center technician will send this pattern when a remote test system is available. Step 2 At the customer Service Interface, the Outside Technician must connect a BERT Test Set to the receive cable pair. The test set should be set to measure the receive signal level in dbdsx. See the specific test set manual for setup. The measured level must be between 0 and db at the Service Interface CURRENT MEASUREMENT (also known as Milliamp test) USED ON STANDARD SPANS ONLY FROM THE NETWORK INTERFACE/SMARTJACK Use a volt meter that measures voltage with at least 2 decimal point accuracy. On a smartjack or NCTE measure the 10
13 voltage between the two test points labeled CURRENT or VOLTAGE. The voltage should be 0.6 VDC +/ volts to equal 60ma. NOTE: Current measurement test is not required when the span is fiber out to the customer site and the smartjack is located in the same bay or adjacent bay as the mux and is locally powered by the same power plant as the mux QRSS (Quasi Random Signal Sequence) TEST PATTERN This pseudo-random sequence is based on a 20-bit shift register and generates every possible combination of 20-bits (except all zero) and repeats every 1,048,756 bits. Before transmission into the network, this sequence is limited to 14 zeros so that it meets the 15-zero limitation when framed. The sequence has an average ones density of 50 percent. This pattern is good for simulating traffic in a T1 system and has been shown to be similar in spectral content to voice traffic. Pattern Table 6: QRSS TEST PATTERN FOR AMI AND B8ZS LINE CODING Average Ones Density Maximum Zeros Circuit Stressed QRSS (un-framed) 50% 14 Timing and Equalization QRSS (framed) 50% 15 Timing and Equalization in 8 PATTERN (also known as 1:7) This pattern stresses the minimum ones density requirement for repeaters. This pattern will help determine if a timing recovery problem exists with low-density patterns. When framed, the bits that are ones must be located in the second bit position of each byte within the frame or a yellow alarm will occur. This is used to test the minimum ones density for a B8ZS line code F
14 Pattern Table 7: 1 in 8 TEST PATTERN FOR B8ZS LINE CODING Average Ones Density Maximum Zeros Circuit Stressed 1 in 8 (un-framed) 12.5% 7 Timing 1 in 8 (framed)* 12.5% 8 Timing *When the 1 in 8 bit pattern is sent with framing bits, the 1 bit must be located in the second position to prevent a yellow alarm or excessive zero condition in 24 PATTERN This pattern simultaneously stresses both the minimum ones density and the maximum number of consecutive zeros. This sequence is useful for testing the timing recovery circuit of the repeater. When framed, the frame bit must be located in the position identified, or either a yellow alarm or a sequence of 16 zeros will occur. This is used to test the minimum ones density for an AMI line code F Pattern Table 8: 3 in 24 TEST PATTERN FOR AMI LINE CODING Average Ones Density Maximum Zeros Circuit Stressed 3 in 24 (un-framed) 12.5% 15 Timing 3 in 24 (framed)* 12.5% 15 Timing The frame bit location must be as specified to prevent a D4 yellow alarm or excessive zero condition ALL ONES This sequence is useful for stressing the regenerator circuit of a repeater. When received, the all ones sequence causes the repeater to consume the maximum amount of power. If inadequate, DC power is provided by the office repeater through the simplex current path, which may cause the repeater to drop out. 12
15 Pattern Table 9: ALL 1'S TEST PATTERN FOR AMI AND B8ZS LINE CODE Average Ones Density Maximum Zeros Circuit Stressed All Ones (un-framed) 100% 0 Regenerator and DC current All Ones (framed) 99.7% 1 Regenerator and DC current 5.7. ALL ZEROS TEST PATTERN The ALL ZEROS must be used for verifying correct optioning for B8ZS line code. The all zero should not be used as a stress BRIDGED TAP TEST A problem, often encountered in the deployment of DS1 facilities via existing networks, is the "unrecorded" bridged tap. A bridged tap is an unterminated pair of wires of unspecified length which generally occurs when service to one customer is terminated and a portion of the same wire pair is re-used for a second customer. The wire run to the site of the previous customer frequently remains connected. It is recommended that the bridged tap be used as a tool to identify trouble conditions that may not be totally defined when using the standard stress tests. The test is used on standard spans when other tests fail, or if a new pair is obtained on a maintenance case of trouble. This test is conducted on the copper portion of the loop only. Document T1M1.3/92-006R2, titled "A Technical Report on The Test Patterns for DS1 Circuits," is an excellent resource for explanations of various s used for testing DS1 circuits. NOTE: For Maintenance, Bridged Tap tests are only required for a chronic trouble if the copper facilities were changed to restore service. For Provisioning, Bridged Tap tests are only required when other stress s fail on standard spans NON-STANDARD TESTS - BILLABLE TESTS Often, customers request the use of non-standard s to identify DS1 circuit faults, e.g., the Daly Pattern (55 Octet). Trouble reports are not taken solely on the result of a failed 55 Octet test. Inform the customer that the pattern they are requesting isn't an ATT standard. ATT will run the based upon the availability of test sets that have the pattern requested. Circuits will not be redesigned based on the 55 Octet test. Follow normal maintenance restoration procedures. ATT will not incur additional expense for engineering costs or redesigns with a failed 55 Octet test. NOTE: The 55 Octet test and other non standard tests are billable tests for both provisioning and maintenance. 13
16 PB/NB: Tech Pub L PB/NB that is available upon customer request contains parameters from this document for provisioning and maintenance tests. Note that anytime a test is repeated by the ATT technician at the testers discretion is not billable to the customer. Tests that are performed by the ATT technician at the request of the customer that are longer than standard durations are billable to the customer. The ATT technician can state in the circuit log if there are reasons why billing does not occur. 6. Attachment 1 - DS1 SERVICE MB/S TESTING PROCEDURES, PROVISIONING AND MAINTENANCE Test requirements. 1. INTRODUCTION Below are test requirements for the provisioning and maintenance of DS1 services. These guidelines are intended to provide a base for testing DS Mb/s High-Capacity Digital Services. These guidelines incorporate the use of specific bit patterns to perform stress tests in conjunction with the conventional QRSS tests for AMI and B8ZS line codes. Stress testing is done after basic continuity is established. Stress testing is used as a diagnostic tool for determining the integrity of a Mb/s DS1 facility. B8ZS line code verification is not a standard test. B8ZS line code verification is not used on circuits that are to be optioned B8ZS. It is used when line code mismatches are suspected. (AMI circuit is suspected of being optioned B8ZS in error at one or more muxes.) The SSTC always has the option of phoning each CO where muxes are located to verify the line code options. When that cannot be done, see Section 4 for flow chart to verify B8ZS multiplexer optioning. Many customers perform longer test durations that range from 2 hours to 24 hours. Additional test durations may be required depending on the test results received from our customers. The charts below indicate the type of tests and parameters that will be taken on all HiCaps. Results will be recorded on the WFA/C OSSCN (Circuit Notes in WFA/C) screen. 2. PROVISIONING TESTS Provisioning tests below are separated into 4 categories: AMI Standard (Non-HDSL) Spans in Table 1. AMI HDSL Spans in Table 2. B8ZS Standard (Non-HDSL) Spans in Table 3. B8ZS HDSL Spans in Table 4. All test parameters tables are for use after continuity is verified. Local practice will dictate sectionalization strategies. 14
17 Table 10: AMI Standard (Non-HDSL) Spans - Provisioning Required Tests General Information Parameters DB Loss Test Unframed all ones pattern sent from CO or remote test system. Measurements at NI. 0 to db Span Current NOTE: Current measurement test is not required when the span is fiber out to the customer site and the smartjack is located in the same bay or adjacent bay as the mux and is locally powered by the same power plant as the mux. Use a volt meter that measures voltage with at least 2 decimal point accuracy. On a smartjack or NCTE, measure the voltage between the two test points labeled current or voltage. Voltage meaurement must be 0.6 VDC +/ volts to equal 60ma. Current measurement if taken in milliamps must be 60 ma +/- 3ma. QRSS 1 five minute test 3 in 24 1 two minute test All Ones 1 two minute test Bridged Tap test is run on copper portion of spans only, when errors are detected on other stress patterns 21 s (test sets are programmed to run these tests) Only use this test on copper spans. 15
18 Table 11: AMI HDSL Span - Provisioning Required Tests General Information Parameters Pulse (Attenuation) HDSL reading at customer premises (This reading is taken once there is continuity between the 2 HDSL units and HDSL sync has been acquired) Retrieve reading via menu software. ADC/Pairgain 0 to -28 db (Each link when doublers are used.) Adtran HDSL and HDSL2 0 to -30 db (Each link when doublers are used.) Adtran HDSL4 0 to -35 db (No regenerator or 1st link ( CO to regenerator)) 0 to -31 db (Regenerated signal 2nd link (regenerator to premise.)) Signal to Noise Signal Quality Margin HDSL reading at customer premises (This reading is taken once there is continuity between the two HDSL units and HDSL sync has been acquired) Retrieve reading via menu software. ADC/Pairgain or Adtran(HDSL, HDSL2 or HDSL4) 6 or greater Signal Level HDSL card reading at customer premises Measure signal at drop side of HDSL card (RJ48C) ADC/Pairgain or Adtran 0 to -7.5 DB Note: 0 DB level may be as high as +1.6 DB QRSS 1 five minute test 3 in 24 1 two minute test All Ones 1 two minute test On All HDSL Cards: 16
19 Date and time must be set. Actual pair loss for HDSL and HDSL2 should not exceed -35 db at 196 khz using a 135 # termination per link or section. This is not a required test. Actual pair loss for HDSL4 should not exceed -44 db at 196 khz using a 135 # termination for circuits not using a regenerator or on the first link ( CO to regenerator) of a circuit using regeneration. Actual pair loss on the second link ( regenerator to premise) should not exceed -41 db at 196 khz using a 135 # termination. Sync light should be green for Adtran units. For ADC/Pairgain, reading should be between -64 to +64 for good synchronization. 17
20 Table 12: B8ZS Standard (Non-HDSL) Spans - Provisioning Required Tests General Information Parameters DB Loss Test Unframed all ones pattern sent from CO or remote test system. Measurements at NI. 0 to DB Span Current NOTE: Current measurement test is not required when the span is fiber out to the customer site and the smartjack is located in the same bay or adjacent bay as the mux and is locally powered by the same power plant as the mux. Use a volt meter that measures voltage with at least 2 decimal point accuracy. On a smartjack or NCTE, measure the voltage between the two test points labeled current or voltage. Voltage meaurement must be 0.6 VDC +/ volts to equal 60ma. Current measurement if taken in milliamps must be 60 ma +/- 3ma. QRSS 1 five minute test 1 in 8 1 two minute test All Ones 1 two minute test All Zeros 1 thirty second test Bridged Tap test run on copper portion of spans only when errors are detected on other stress patterns 21 s (test sets are programmed to run these tests) Only use this test on copper spans. 18
21 Table 13: B8ZS HDSL Spans - Provisioning Required Tests General Information Parameters Pulse (Attenuation) HDSL card reading at customer premises (This reading is taken once there is continuity between the 2 HDSL units and HDSL sync has been acquired) Retrieve reading via menu software. ADC/Pairgain 0 to -28 DB (Each link when doublers are used.) Adtran HDSL and HDSL2 0 to -30 DB (Each link when doublers are used.) Adtran HDSL4 0 to -35 db (No regenerator or 1st link ( CO to regenerator)) 0 to -31 db (Regenerated signal 2nd link (regenerator to premise.)) Signal to Noise Margin HDSL reading at customer premises (This reading is taken once there is continuity between the 2 HDSL units and HDSL sync has been acquired) Retrieve reading via menu software. ADC/Pairgain or Adtran (HDSL, HDSL2 or HDSL4) 6 or greater Signal Level HDSL reading at customer premises Measure signal at drop side of HDSL card (RJ48C) ADC/Pairgain or Adtran 0 to -7.5 DB Note: 0 DB level may be as high as +1.6 DB QRSS 1 five minute test 1 in 8 1 two minute test All Ones 1 two minute test All Zeros 19
22 1 thirty second test Special Note: For Adtran HDSL2 cards used in a Litespan application. Although the Adtran card is shipped with a line code of B8ZS, the Litespan will change that value to the Litespan automatic default of AMI. The Central Office, NOC or SSTC must provision the Litespan to ensure proper line code information is set in the system. SSIM, ATT Midwest ONLY: SPECIAL BOOT PROCESS WHEN T1 RIDES ON A LITESPAN SYSTEM When adding DS1 cards to an existing Litespan system, a boot proc is performed. The SSIM technician will need to verify the software version in the card is the same as the latest software release. If not the same,a boot process will ensure the newest software version is loaded onto the Litespan element. This process only applies to the new card being installed in the Litespan. Doing this on existing cards will cause a momentary hit to service. If a card already is in the Litespan slot ( previous disconnected circuit), and the service is new, the same "boot proc" must be done. To determine if boot proc must be done on a DS1 card for a new circuit installation: retrieve equipment for that card, this will show you what the software release is. Ex: ( ) Retrieve version, this will show the latest software version. ( ) If the software versions do not match, follow the Boot Proc below. To Boot Proc the DS1 card: Display " boot proc" procedure. This procedure is found in the TL1 Messages section under BOOT-PROC. This process must be done on new installs, when the card is reused if the software versions do not match. This procedure is for ATT Midwest only. The NOC normally does this process in other regions. On HDSL Cards: Date and time must be set. Actual pair loss for HDSL and HDSL2 should not exceed -35 db at 196 khz using a 135 # termination per link or section. This is not a required test. Actual pair loss for HDSL4 should not exceed -44 db at 196 khz using a 135 # termination for circuits not using a regenerator or on the first link ( CO to regenerator) of a circuit using regeneration. Actual pair loss on the second link ( regenerator to premise) should not exceed -41 db at 196 khz using a 135 # termination. Sync light should be green for Adtran units. For ADC/Pairgain, reading should be between -64 to +64 for good synchronization. 20
23 NOTE: Above tests constitute acceptable test parameters for circuit turnup in accordance with ANSI Standard T1 403 Figure 1. If these parameters are not met, the tests may be run 1 additional time. If the retest passes, the circuit is considered acceptable for turnup. If the retest fails, sectionalization must be done to isolate the cause of the trouble. Upon sectionalization, the above tests (span type and line code dependent) will be rerun. PB/NB Only: 2.1 Intermittent Errors on Above Provisioning Tests Extended tests may have to be run for test acceptance, due to intermittent errors. Test Duration and Test Table 14: Extended Test Pattern Parameters Errored Seconds (ES) Allowed Severe Errored Seconds (SES) Allowed Consecutive Severe Errored Seconds (CSES) Allowed 5 minutes 1 in 8 (B8ZS) 0 ES in 24 (AMI) All Ones (AMI and B8ZS) 2-15 minute QRSS (AMI and B8ZS) 3 or less ES for each 15 minute QRSS test
24 Facility Type Table 15: 24 Hour Test Parameters (Not a Standard Extended Test) Errored Seconds (ES) Allowed Severe Errored Seconds (SES) Allowed Consecutive Severe Errored Seconds (CSES) Allowed All Fiber CO to NI End to End Fiber/(Copper<5 miles) CO to NI End to End Fiber/(Copper>5 miles) CO to NI End to End Reference: GR 64 Core Issue 1 December POPULATING OSSCN SCREEN IN WFA/C The OSSCN screen will have different fields populated depending on the span type and line coding. The OSSCN screen may be populated by both: SSIM technician - SSIM technician will use Craft Access Remote Testing (CART) SSTC technician - SSTC technician will use WFA/C to populate OSSCN screen. The following fields must be populated for proper documentation during the circuit provisioning process. The only 'required' fields that must be populated by the Special Services Test Center Technician are "ES" and Accepted By. All other fields could by populated by the I & M technician through CART. The SSTC tester has final responsibility upon circuit completion to verify information is populated on the OSSCN screen. The SSIM technician must populate all fields except ES and Accepted By when CART is used to post CTR1 complete. ES - Populate (A-Z), (Z-A), LPBK depending on type of test. Installer - name of installer(s) at A and Z locations. 22
25 Accepted by - name of person accepting service LCON - name and phone number of Local Contact NI A/Z - Physical location, type and position numbers of network interface at customer premises for both A and Z locations if applicable. GRD OK? - Y or N - answer obtained from Installation and Maintenance Technician. The technician will determine the span type and populate fields on OSSCN according to type. Below is the required input on OSSCN screen for standard spans, without Intelligent Office Repeaters or Intelligent Line Repeaters. DB - Record loss at demarc with unframed all ones sent. MA - Record span current - record voltage or current measurement here Required Input on OSSCN screen for HDSL Spans - no doublers PA - Pulse Attenuation MRGN - Signal to Noise Margin 2W HDSL Y or N Required Input on OSSCN screen for HDSL Spans with Doublers PA - Pulse Attenuation MRGN - Signal to Noise Margin CO-LP1/LP2 - Reading of CO to first doubler R1-LP1/LP2 - Doubler #1 Loop1 to Loop 2 R2-LP1/LP2- Doubler #2 Loop1 to Loop2 REM-LP1/LP2 - Remote unit 3.0 MAINTENANCE TESTS 23
26 Automated Testing and Analysis System (ATAS) is the automated system that will populate test results in the log of WFA/C. These test results are used for trouble sectionalization when a trouble is not chronic or intermittent. See Section 5, ATAS testing. Maintenance testing procedures will vary depending on the type of trouble reported. The initial and sectionalization strategies used for trouble isolation should be at the discretion of the tester. Special Note: Any trouble report that is a chronic trouble or intermittent errors reported, must utilize Table 5, Extended Test Pattern Parameters. A circuit does not have to be intermittent or chronic to view Performance Monitoring(PM) data. Current status and history PM data is available from both the Adtran and ADC/ Pairgain HDSL units. If no trouble is found, the CO or outside field technician can utilize current status and history from the HDSL units to help sectionalize the trouble. Other PM data may be available depending on equipment used in circuit design. See local practices for PM retrieval on specific equipment types. After the trouble has been isolated and repaired, the following tests should be performed: Table 16: Maintenance Test Patterns AMI Line Code Required Tests General Information Parameters QRSS 1 five minute test 3 in 24 1 two minute test All Ones 1 two minute test 24
27 Table 17: AMI HDSL Span - Maintenance Required Tests General Information Parameters Pulse (Attenuation) HDSL card reading at customer premises ADC/Pairgain 0 to -28 DB (Each link when doublers are used.) Adtran HDSL and HDSL2 0 to -30 DB (Each link when doublers are used.) Adtran HDSL4 0 to -35 db (No regenerator or 1st link ( CO to regenerator)) 0 to -31 db (Regenerated signal 2nd link (regenerator to premise.)) Signal to Noise Margin HDSL card reading at customer premises ADC/Pairgain or Adtran 6 or greater Signal Level HDSL card reading at customer premises ADC/Pairgain or Adtran 0 to -7.5 DB Note: 0 DB level may be as high as +1.6 DB QRSS 1 five minute test 3 in 24 1 two minute test All Ones 1 two minute test On HDSL Cards: Date and time must be set. Actual pair loss should not exceed -35 db at 196 khz using a 135 # termination per link or section. This is not a 25
28 required test. Actual pair loss for HDSL4 should not exceed -44 db at 196 khz using a 135 # termination for circuits not using a regenerator or on the first link ( CO to regenerator) of a circuit using regeneration. Actual pair loss on the second link ( regenerator to premise) should not exceed -41 db at 196 khz using a 135 # termination. Sync light should be green for Adtran units. For ADC/Pairgain, reading should be between -64 to +64 for good synchronization. ATT Midwest Only: H4TU-C for Soneplex There are currently 2 versions of the H4TU-C card used for Soneplex and these cards use different technology and cannot be swapped out from first generation to second generation and vice versa without reprovisioning.. When a card is pulled from a slot and replaced with a card of a different technology the first card must be deprovisioned and the slot must be made unequipped before pulling the old card and replacing it with the new. The slot with the new card must be set equipped at this time and the card also needs to be placed in-service and provisioned. This same procedure needs to be applied when changing 1st generation H4TU-C cards with 2nd generation H4TU-C cards and vice versa, even though the cards are seemingly the same technology. Not following this procedure will cause a loss of communication to the card and will need a dispatch to the location of the card with a customer release to take down the circuit to resolve the problem. Until the problem is corrected, the SCU will see the slot as having a mismatch. Tech Support states if there are too many mismatches, communications can be lost to the entire shelf. T1L6CDLBAA and T1L4XNJCAA - First generation cards T1L6CDFBAA Second generation card ( different technology from first generation cards) After a card is replaced, technicians must log into the Soneplex shelf and check the equipment status of the card on the Trouble Isolation screen located in the System Maintenance menu. If the status shows a Comm Failure there is a problem and the card was most likely not provisioned when it was changed. A mismatch can also be checked on the Configuration Validation screen located in the Unit Configuration menu. A mismatch will be indicated by "mis" in the card field. See Tech Bulletinplex%20LEC.txt for additional information. 26
29 Table 18: Maintenance Test Patterns B8ZS Line Code Standard Spans Required Tests General Information Parameters QRSS 1 five minute test 1 in 8 1 two minute test All Ones 1 two minute test All Zeros to check for B8ZS line code Bridged Tap (non HDSL span only) 21 s test run on copper portion of spans only when errors are detected on other stress patterns, when there is a chronic trouble, or when a pair change is made 27
30 Table 19: B8ZS HDSL Spans - Maintenance Required Tests General Information Parameters Pulse (Attenuation) HDSL card reading at customer premises ADC/Pairgain 0 to -28 DB (Each link when doublers are used.) Adtran HDSL and HDSL2 0 to -30 DB (Each link when doublers are used.) Adtran HDSL4 0 to -35 db (No regenerator or 1st link ( CO to regenerator)) 0 to -31 db (Regenerated signal 2nd link (regenerator to premise.)) Signal to Noise Margin HDSL card reading at customer premises ADC/Pairgain or Adtran 6 or greater Signal Level HDSL card reading at customer premises ADC/Pairgain or Adtran 0 to -7.5 DB Note: 0 DB level may be as high as +1.6 DB QRSS 1 five minute test 1 in 8 1 two minute test All Ones 1 two minute test All Zeros 1 thirty second test Special Note: For Adtran HDSL2 cards used in a Litespan system. Although the Adtran card is shipped with a line code of B8ZS, the Litespan will change that value to the Litespan automatic default of AMI. The Central Office, NOC or 28
31 SSTC must set the Litespan linecode to B8ZS to ensure proper line code information is set in the Litespan system line card. The SSIM technician is not able to make this change at the remote unit. NOTE: Above tests become optional ONLY if the customer waivers test. (Hard trouble cleared and customer requests circuit for immediate use.) It must be noted in the OSSLOG with customer name and phone number." 4.0 B8ZS LINE CODE VERIFICATION SPECIAL NOTE: This test is not normally performed. This test is primarily for use on AMI circuits. (Errors detected on loopback and mux line code option is suspected. ) To verify muxes are optioned correctly, the SSTC can call each CO where there is a mux to verify muxes are optioned AMI. If that cannot be done and the SSTC or other tech suspects a mux(s) is optioned B8ZS in error, the following test may be performed. See flowchart in figure 1, below, to verify line code option in mux is optioned B8ZS in error. This verification is NOT a required test. Note: All zeros is the normal test to verify B8ZS circuit operation on circuits designed with a line code of B8ZS. This test is primarily used when the line code is AMI and the tester needs to verify the multiplexer is not optioned B8ZS in error, or a line code mismatch on each side of a span. 29
32 Figure 1: B8ZS Line Code Verification NOTE: Do not utilize loopbacks to run this line code verification. A straight-away test is used. This test may be run from remote test access points, with field technicians in the Central Office or at customer premises. 30
33 5.0 ATAS TESTING 5.1 Circuits tested by ATAS ATAS will grab a new report from the WFA/C trouble list when the following conditions are met: The circuit ID Service Code must be among the service codes in the ATAS tables. The FLC code for the trouble report must be one that ATAS works from. The trouble report must be a Customer Report (CR). TEST field on the OSSTRE screen is populated with a Y (Yes). The TYPE field on the OSSTRE screen must not be RFR. The TEST field on the OSSTRE screen in WFA/C when populated with an N (NO) will trigger ATAS to add a note to the log (OSSLOG) that the test flag is set to N and drop the ticket for manual intervention. ATAS TEST FLOW Below is a condensed recap of the ATAS trouble flow. See ATAS documentation for complete flows. ATAS monitors the circuit in each direction for 15 seconds from the test point closest to the A end of the circuit. ATAS notes access ID information in the log(osslog). ATAS looks for loopable devices on the WORD document. All ATAS tests are from the test point closest to the A end, and will attempt to loop equipment farthest from the A end. Human Equipment Code Item(HECI) codes on a WORD document identify loopable equipment. Verbiage such as Demarc - 4W on the WORD document also is a trigger for ATAS to know there is loopable equipment. ATAS will assume there is a Smart Jack on the circuit when Demarc - 4W verbiage is seen on the WORD document. This causes ATAS to attempt to loop the CSU at the Z end of the circuit. ATAS will attempt to loop the circuit from the same test point it used to monitor the circuit. Successful loopback of the CSU will result in a TOK - No trouble found message in the OSSLOG. CSU loopback failure causes ATAS to attempt to loop the smart jack. ATAS continues with this sectionalization process. ATAS will use the line code from the WORD document, however will check the other line code if errors are run on a loopback. ATAS will note the line code used to produce error free results if other than the line code specified on the WORD document. DURATION OF ATAS TESTS Loopback tests will be one minute in duration for all s except all zeros. The all zeros is 15 seconds in duration. TEST PATTERNS USED by ATAS 31
34 Test patterns used are determined by the line coding. ATAS will run these tests depending on the line code ATAS is checking for. AMI ATAS tests are: QRSS 3 in 24 All ones B8ZS ATAS tests are: QRSS 1 in 8 All ones All zeros ATAS populates the log with test results. The test results in the log should be used to assist with trouble sectionalization. The tester always has the option of running extended duration tests utilizing the Remote Access and Test System(REACT). 7. Attachment 2 - Acronyms 1 in 8-3 in 24 - All Ones - All Zeros - AMI - Alternate Mark Inversion line coding AML - Actual Measured Loss - See definition in Attachment 3 ATAS - Automated Testing and Analysis System 32
35 B8ZS - Binary with 8 Zero Substitution line coding BERT - Bit Error Rate Test BT - Bridged Tap - See definition in Attachment 3 CART - Craft Access Remote Testing CLCI - Common Language Circuit Identification CLFI - Common Language Facility Identification CO - Central Office CSES - Consecutive Severe Errored Seconds D4 Framing - Superframe DB - Decibel DS1 - Digital Signal Megabits/second DSX - Digital Signal Cross Connect Bay in CO EML - Engineered/Estimated Measured Loss - See definition in Attachment 3 ES - Errored Seconds ESF - Extended Superframe FEXT - Far End Cross Talk - See definition in Attachment 3 HDSL - High-Bit-rate Digital Subscriber Line HECI - Human Equipment Code Item - (11 character code naming revision level of card to be used) ILR - Intelligent Line Repeater IOR - Intelligent Office Repeater ma - milliamps - current measurement NCI - Network Channel Interface NCTE - Network Channel Terminating Equipment NEXT - Near End Cross Talk - See definition in Attachment 3 NI - Network Interface OSSCN - WFA/C screen for Circuit Notes - Test readings are recorded on this page 33
36 PA - Pulse Attenuation - See definition in Attachment 3 PM - Performance Monitoring PROCDS - TIRKS Model QRSS - Quasi Random Signal Sequence - r REACT - Remote Access and Test System SES - Severe Errored Seconds SNR - Signal to Noise Ratio - See definition in Attachment 3 SR - Synch Readings - See definition in Attachment 3 SSIM - Special Services Installation and Maintenance SSTC - Special Services Test Centers STS - Synchronous Transport Signal WFA/C - Work Force Administration / Control WORD - Work Order Record Detail 8. Attachment 3 - HDSL TERMINOLOGY AND DEFINITIONS AML - Actual Measured Loss; The loss measured (35 db max) using two test sets at 196 khz with 135 ohms terminations on both ends of an HDSL span section ( CO to Remote, CO to Repeater, Repeater to Remote, or Repeater to Repeater in the form of 4W-HDSL ). AML can also be the measurement made by the HDSL equipment when using a laptop or dumb terminal device in the RS232 jack on the face of the units. BT - Bridged Tap; Any section of a cable pair not on the direct electrical path between the central office and the end user. (A bridged tap increases the electrical loss on the pair - because a signal traveling down the pair will split its signal between the bridge and main pairs). HDSL BT parameters: Total bridged tap length on any HDSL span may not exceed 2.5 kft. No single bridged tap section may exceed 2.0kft. on any HDSL span. All 26 gauge cable plus bridged tap, may not exceed 9kft 34
37 Single or multi-gauge ( 19, 22, or 24 ) cable plus bridged tap may not exceed 12 kft HDSL2 requires that Multi-gauge containing 26-gauge cable plus bridged tap may not exceed 9 kft. This conforms to Carrier Serving Area Guidelines (Loop Deployment Policy and Guidelines, Section 4.1.1, 9/00). EML - Engineered/Estimated Measured Loss; The engineering approximation of loss on a loop using Carrier Serving Area ( CSA ) design rules ( 35 < db depending on local guidelines ) for an HDSL span. This is an estimation of the AML, but takes into consideration the quality of the plant, environmental temperature fluctuation, record inaccuracies, BT and gauge changes. FEXT - Far-End X-Talk(crosstalk). A type of crosstalk which occurs when signals on one twisted pair are coupled to another pair as they arrive at the far end of multi-pair cable system. FEXT is an issue on short loops supporting high-bandwidth services such as VDSL (Very-high-bit-rate Digital Subscriber Line), given the relatively high carrier frequencies involved. Services such as ADSL and HDSL are not affected to the same extent, as the loops are longer and as such interference tends to be attenuated (weakened) on longer loops. NEXT - Near-End X-Talk. A type of crosstalk which occurs when signals transmitted on one pair of wires are fed back into another pair. Since at this point on the link the transmitted signal is a maximum strength and the receive signal has been attenuated, it may be difficult to maintain an acceptable ACR (Attenuation-to-Crosstalk Ratio). NEXT is particularly troublesome when a number of high-speed transmission services (e.g., ADSL, HDSL and T- carrier) are supported within a single copper cable system. Shielded or screened cable systems are more desirable in addressing this problem than are unshielded varieties. PA - Pulse Attenuation; The HDSL equipment measured loss on all sections in a HDSL designed span ( 28 to 30 db max depending on the manufacturer ). This PA reading must be determined by using a laptop or dumb terminal at the RS232 jack of the HDSL unit. Adtran = 30 db (HTU-C/HTU-R) Pair Gain Technologies = 28 db (HLU/HRU) ADC HDSL Loop Extender Shelf = 31dB (HLXC/HLXR) SNR - Signal to Noise Ratio; The ratio of the usable signal being transmitted to the noise or undesired signal. Usually expressed in decibels. This ratio is a measure of the quality of a transmission. The signal to noise difference is measured by the HDSL equipment and using a laptop or dumb terminal at the RS232 jack to get the reading. SR - Sync Readings; Loss of synchronization between HDSL units as measured by the HDSL equipment using a laptop or dumb terminal at the RS 232 jack on the HDSL units 9. Attachment 4 - HDSL Remote Unit Problems 4.1 A study was done on returned HDSL remote units. 35
38 38% of the units returned were found to have been subjected to a power surge. Proper grounding eliminates this problem. 38% of the units had no trouble found. This indicates the units may have been optioned incorrectly or were placed on marginal loops. 24% of the units returned had a problem with an undersized capacitor. New units come with the correct size capacitor. In conclusion: Verify grounding connections Provide all test results to SSTC to record in WFA/C on OSSCN screen On the new T200 Low-Voltage HTU-R circuit pack from Adtran, the ground is located on pins 1,11 and 27. This is compatible with the Troncom mounting that is used, as the ground is on pin 27 of the mounting. Older Adtran units with a ground on pins 1 or 11 will require an additional connection to pin 27 of the mounting to obtain a good chassis ground. 36
How To Test A Ds1 Signal
T1 Installation and Maintenance INTRODUCTION T1 also known as Digital Signal level 1(DS1) is a digital technology that was created during the 1960s to carry voice and data services. The original focus
FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS
Tech Notes from a Telephone Engineer FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS DDS Description: DDS Digital Data Service Long held industry acronym for transporting digital data at rates of: 2.4kbps,
HDSL Basics. HDSL Basics. Introduction. HDSL Overview
1 Introduction Providing T1 service is a competitive race, and High-bit-rate Digital Subscriber Line () is quickly emerging as the ideal solution to remain a step ahead. Currently touted as repeaterless
T1 Networking Made Easy
T1 Networking Made Easy 1 THE T1 CARRIER 3 WHAT DOES A T1 LOOK LIKE? 3 T1 BANDWIDTH 3 T1 PHYSICAL CHARACTERISTICS 4 T1 FRAMING 5 LINE CODE 6 T1 NETWORKING 6 TELCOS 6 PSTN ACCESS WITH A T1 8 SUMMARY OF
Appendix D T1 Overview
Appendix D T Overview GENERAL T refers to the primary digital telephone carrier system used in North America. T is one line type of the PCM T-carrier hierarchy listed in Table D-. T describes the cabling,
2-Pair HDSL1 Adtran Fiber Optic Link System
ISSUE 2 June 01, 2004 Data Sheet #37 2-Pair HDSL1 Adtran Fiber Optic Link System Contents 1. General. 1 2. Application... 2 3. Housings.. 2 4. Installation 3 5. Provisioning. 5 6. LED Indicators. 6 7.
Chapter 4 T1 Interface Card
Chapter 4 T1 Interface Card GENERAL This chapter describes DTE interface options that may be required if application requirements change. It also describes software configuration for the T1 interface card.
The Common Test Patterns described below are used to test DS1 interfaces upon initial installation and after repair.
Introduction DS1 test patterns are predetermined, repeating one and zero bit sequences that are translated into pulses according to the line coding rules for AMI and B8ZS. A test pattern is transmitted
UltraFED IIB. 30 MHz Far-End Device
COMMUNICATIONS TEST AND MEASUREMENT SOLUTIONS UltraFED IIB 30 MHz Far-End Device Key Benefits Faster and more accurate than a single-ended test Eliminate driving to change line conditions Remotely set
- T-Carrier Technologies -
1 T-Carrier Fundamentals - T-Carrier Technologies - T-Carrier systems provide digitized communication for voice or data traffic across a telephone provider s network. The T-Carrier specification defines
Westell IDR9186SB Intelligent High-Density T1 Office Repeater
Section IDR-918-6SB-201 Equipment Issue 1 030-101673 Rev. A, March 2008 Westell IDR9186SB Intelligent High-Density T1 Office Repeater CLEI* Code: T1R5TAVAAA CONTENTS PAGE # 1 GENERAL....................................
DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management
Bandwidth Management Page 4.1 DigiPoints Volume 1 Module 4 Bandwidth Management Summary This module will cover Time Division Multiplexing (TDM). TDM technology allows many users to access a particular
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
Chapter 4 Connecting to the Internet through an ISP
Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No
T-BERD 107A. T-Carrier Analyzer
T-BERD T-Carrier Analyzer Today s demanding network testing environment calls for an instrument that is powerful, compact, and easy to use. TTC s T-BERD meets all these requirements and more. Ideal for
1. Overview. 2. F-bit Utilization
1. Overview... 1 2. F-bit Utilization... 1 3. T1 Line Signal... 2 4. T1 Alarm Conditions... 3 5. 64 kbps Channel Characteristics... 3 6. Timeslot Handling... 3 7. Unframed Mode... 4 1. Overview The T1
Cisco 8-Port Channelized T1/E1 Shared Port Adapter
Cisco 8-Port Channelized T1/E1 Shared Port Adapter The Cisco I-Flex approach combines shared port adapters (SPAs) and SPA interface processors (SIPs), providing an extensible design that helps prioritize
Transformer-coupled passive transmit path with a fixed insertion loss of approximately 1.0dB.
Charles Industries, Ltd. Section 319 29P 201 Equipment Issue 1 Second Printing, August 1999 STS 3192 9P Short Loop Office Repeater CONTENTS Complies with UL Standard 1459 Second Edition. PAGE Part 1. GENERAL.............................................................................
CAMPUS-RS CSU/DS-1 INTERFACE CARDS
CAMPUS-RS CSU/DS-1 AND CSU/DSX-1 INTERFACE CARDS USER MANUAL Revision History of This User Manual To acquire copies of this user manual, order document catalog number 500-931-150-03. Issue Release Date
24-Port Channelized E1/T1 Line Card Overview
CHAPTER -Port Channelized E/T Line Card Overview This chapter describes the Cisco series -port channelized E/T line card (referred to as the -port channelized E/T line card), and contains the following
DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs
554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8 = PDF Leased Line Economical T1 Internet Access Central Site T1 Management T1/FT1 Single-port Plug-in DSU/CSUs Key Features Specifications Ordering Information
Broadband 101: Installation and Testing
Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband
Extending Ethernet over 2-wire Copper Networks
Extending Ethernet over 2-wire Copper Networks Executive Summary To improve the efficiency of industrial automation systems, many operators are considering the possibility of IP upgrades to provide centralised
Configuring E1 and T1 Interfaces
4 Configuring E1 and T1 Interfaces Contents Overview of E1 and T1 WAN Connections.......................... 4-3 Elements of an E1- or T1-Carrier Line.......................... 4-3 Connecting Your Premises
Configuring E1 and T1 Interfaces
4 Configuring E1 and T1 Interfaces Contents Overview of E1 and T1 WAN Connections.......................... 4-3 Elements of an E1- or T1-Carrier Line.......................... 4-3 Connecting Your Premises
The Conversion Technology Experts. Media Conversion: Cost-Effectively Integrating T1 into your Fiber Network
The Conversion Technology Experts Media Conversion: Cost-Effectively Integrating T1 into your Fiber Network Media Conversion: Cost Effectively Integrating T1 into Your Fiber Network Revealing some simple
VIPTA - Verizon Internet Provider Test Acceptance
VIPTA - Verizon Internet Provider Test Acceptance VIPTA (Verizon Internet Provider Test Acceptance) The VIPTA process is an email that a customer will receive once Verizon has completed all the required
Introduction to Digital Subscriber s Line (DSL)
Introduction to Digital Subscriber s Line (DSL) Professor Fu Li, Ph.D., P.E. Chapter 3 DSL Fundementals BASIC CONCEPTS maximizes the transmission distance by use of modulation techniques but generally
How To Power A Powerline System On A Cell Phone Or Ipad Or Ipa Computer (For A Cell)
Digital Loop Carrier System 12:1 Multi-Line System 12 lines over a single twisted pair: Expand customer service to a range of up to 100,000 ft. without the expense of installing new copper G The 12:1 Multi-Line
Digital Subscriber Line (DSL) Transmission Methods
Digital Subscriber Line (DSL) Transmission Methods 1. Overview... 1 2. SHDSL Transmission Methods... 1 SHDSL Transmission System Versions... 1 SHDSL Transmission Subsystem Structure... 1 SHDSL Modulation
Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)
CNAP @ VCC 1 of 8 LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes) Objectives: Understand the function of a T1 Service Unit (TSU) in network telecommunications Connect routers
T3 E3 and T1 E1 Controller Commands on Cisco IOS XR Software
T3 E3 and T1 E1 Controller Commands on Cisco IOS XR Software This module describes the commands to configure T3/E3 and T1/E1 controllers on routers supporting Cisco IOS XR software. HR-321 bert e1 T3 E3
Working with T3 and T1: Technology, Troubleshooting and Fault Location
Working with T3 and T1: Technology, Troubleshooting and Fault Location Sunrise Telecom... A Step Ahead 1 Overview This handbook gives you an overview of T3 and T1 technology and equipment. It also shows
Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I
22116 23 rd Drive SE Bothell, WA 98021-4413, USA Toll free 800-426-3926 425-487-1515 Fax 425-487-2288 E-mail [email protected] www.teltone.com Application Note: Extending a s Analog Capabilities Using an
Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)
Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view) Gilberto GG Guitarte, BB Connectivity Director TE Connectivity FTTH LATAM Chapter CHAIRMAN 2/24/2014 G.A.Guitarte 1 Executive
Adtran TA3000 (Rural DSLAM) Notes
Adtran TA3000 (Rural DSLAM) Notes The Adtran TA3000 will be connected to a Host C.O. Alcatel 7300 DSLAM as illustrated in the diagram below. The TA3000 and Alcatel 7300 communicate using IMA (Inverse Multiplexing
Physical Layer, Part 2 Digital Transmissions and Multiplexing
Physical Layer, Part 2 Digital Transmissions and Multiplexing These slides are created by Dr. Yih Huang of George Mason University. Students registered in Dr. Huang's courses at GMU can make a single machine-readable
T1 Network Technology. Essentials for Successful Field Service Technicians
T 1 Te s t i n g : Te c h n o l o g y T1 Network Technology a n d A p p l i c a t i o n s Essentials for Successful Field Service Technicians Introduction The public wireless telephony business has gone
Acterna DSL Services Tester TPI 350+ Application Highlights
Acterna TPI 350+ DSL Test Set Product Highlights Field engineered, rugged construction, lightweight design, and batterypowered operation Automated testing capabilities minimize training costs and testing
DCM555 - Data Communications Lab 8 Time Division Multiplexing (TDM) Part 1 - T1/DS1 Signals
DCM555 - Data Communications Lab 8 Time Division Multiplexing (TDM) Part 1 - T1/DS1 Signals Name: St. #: Section: (Note: Show all of your calculations, express your answer to the appropriate number of
How To Test A Network For Fault Tolerance
T OVERVIEW THE HIGH-CAPACITY DIGITAL NETWORK MeterCenter (800) 230-6008 (480) 659-835 Outside USAeteM TABLE OF CONTENTS THE HIGH-CAPACITY DIGITAL NETWORK......................................................2
Cisco 2- and 4-Port Clear Channel T3/E3 Shared Port Adapters Version 2
Data Sheet Cisco 2- and 4-Port Clear Channel T3/E3 Shared Port Adapters Version 2 Demand for high-capacity corporate backbones, for high-speed access to the global Internet, and for trunking connections
T1 Basics. T1 Basics. Introduction. Why is T1 in Demand? Overview. Simplification
1 Introduction When a technology gains rapid acceptance, it often reaches buzzword status before the details are commonly understood. So it is with T1: although it is an important part of many communications
technical note T1 Basics
technical note T Basics T Basics hen a technology gains rapid acceptance, it often reaches buzzword status before the details are commonly understood. So it is with T: although it is an important part
SRX 210 Services Gateway T1 Interface Configuration
SRX 210 Services Gateway T1 Interface Configuration To configure a T1 interface: 1. Select Configuration > Quick Configuration > Interfaces if the Interfaces Quick Configuration page is not displayed.
Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS
Application Note Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS The JDSU SmartClass TPS tester is the ideal tool for technicians who install, troubleshoot,
Advanced Signal Processing 1 Digital Subscriber Line
Advanced Signal Processing 1 Digital Subscriber Line Biljana Badic e-mail: [email protected] 1. I n t r o d u c t i o n As a transmission technology, digital subscriber line was originally developed
(Refer Slide Time: 2:10)
Data Communications Prof. A. Pal Department of Computer Science & Engineering Indian Institute of Technology, Kharagpur Lecture-12 Multiplexer Applications-1 Hello and welcome to today s lecture on multiplexer
Total Access SHDSL T1/E1 Line Terminating Unit Installation and Maintenance Practice
Section 680L-5A Issue, August 00 Total Access T/E Line Terminating Unit Installation and Maintenance ractice CNTENTS. General.... Description.... Installation.... rovisioning... 5. peration... 5 6. Maintenance...
DigiPoints Volume 1. Student Workbook. Module 5 Growing Capacity Through Technology
Growing Capacity Through Technology Page 5. 1 DigiPoints Volume 1 Module 5 Growing Capacity Through Technology Summary This module covers the North American Digital Hierarchy (NADH), the European Digital
Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters
Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters The Cisco I-Flex approach combines shared port adapters (SPAs) and SPA interface processors (SIPs), providing an extensible design that
SRX 210 Services Gateway T1/E1 Mini-Physical Interface Module
SRX 210 Services Gateway T1/E1 Mini-Physical Interface Module The T1/E1 Mini-PIM provides the physical connection to T1 or E1 network media types and also performs T1 or E1 framing and line-speed signaling.
SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C37.94. Fiber Service Units
SOLUTIONS FOR AN EVOLVING WORLD T1/E1 and C37.94 Fiber Service Units T1/E1 & C37.94 1 April 2013 Your world is changing and so are we. At RFL, we know your needs change much faster than your infrastructure.
TAM1500-12 12-Port T1 Access Multiplexer
TAM1500-12 12-Port T1 Access Multiplexer Interface Module User Guide CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling this equipment.
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
Loop-V4300 MINI DACS E1/ T1 CONVERTER
MINI DACS Loop-V4300 MINI DACS / CONVERTER Description Loop-V4300 Mini DACS / converter provides both DS0 and n x 64 Kbps cross-connect between any and ports and to format conversion functions. to conversion
What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France
Title: Source: Author: Contact: What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France Jack Douglass Jack Douglass Paradyne Networks, Inc. Voice: 949-233-3558 Email:
TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber
Installation Instructions TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber CAUTION Net to Net Techlogies strongly recommends the use of proper electrostatic discharge (ESD)
FlexPoint T1/E1 Copper to Fiber Line Driver
BLACK BOX NETWORK SERVICES MT660A-MM MT661A-SM MT660A-MM-E MT661A-SM-E FlexPoint T1/E1 Copper to Fiber Line Driver CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500)
ORION TELECOM NETWORKS INC. T1
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,
UIM-2T1 T1 Loop Bonding Uplink Interface Module
Installation Instructions UIM-2T1 T1 Loop Bonding Uplink Interface Module CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling this
BROADBAND AND HIGH SPEED NETWORKS
BROADBAND AND HIGH SPEED NETWORKS INTRODUCTION TO MUTIPLEXING Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single data link INTRODUCTION
WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor
WaveReady CFM Optical Link Monitoring System: Continuous Fiber Monitor www.lumentum.com Data Sheet The Lumentum Continuous Fiber Monitor (CFM) offers a compact, modular solution for performance monitoring
ADSL2 AND ADSL2plus THE NEW ADSL STANDARDS
ADSL2 AND ADSL2plus THE NEW ADSL STANDARDS March 25, 2003 ADSL2 AND ADSL2plus - THE NEW ADSL STANDARDS In July 2002, the ITU completed G.992.3 and G.992.4 1, two new standards for ADSL technology collectively
HST-3000 DS3 Service Interface Module (SIM)
COMMUNICATIONS test & measurement solutions HST-3000 DS3 Service Interface Module (SIM) Key Features Reduce DS3 circuit testing time by using dual receivers for bidirectional monitoring, allowing for timely
Product Overview. Features CHAPTER
CHAPTER 1 This chapter describes the Cisco IAD1101 integrated access device chassis, and the line interface modules supported by the Cisco IAD1101. This chapter includes the following sections: Features
RLH Single Channel T1 Fiber Link Card System
RLH Industries, Inc. The leader in rugged fiber optic technology. USER GUIDE Unconditional Lifetime Warranty U-066 2014A-0205 RLH Single Channel T1 Fiber Link Card System Description The Single Channel
T-carrier. Two Network Interface Units. On the left with a single card, the right with two
T-carrier From Wikipedia, the free encyclopedia Two Network Interface Units. On the left with a single card, the right with two In telecommunications, T-carrier, sometimes abbreviated as T-CXR, is the
Non-Facility Associated Signaling (NFAS)
CHAPTER 5 This chapter describes the option available for system ISDN call processing. The following topics are discussed: Overview of NFAS capabilities NFAS system administration screens NFAS Group Summary
OPERATION FIC SOC (USOC) JACK T1 CSU Interface 04DU9-1SN 6.0N RJ48C 04DU9-1ZN
1. IMPORTANT STUFF The Rhino TM channel bank comes ready to go. This section describes important information you need to know with regard to the warranty and safety information. 1.a. Warranty The Rhino
Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers
Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers The Cisco Channelized T1/E1 and ISDN PRI High-Speed WAN Modules combine multiple T1/E1 WAN connectivity-channelized T1/E1
G.703 Fractional T1 Access Unit. User Guide
G.703 Fractional T1 Access Unit User Guide Description The G.703 T1/FT1 ACCESS UNIT is a single port access unit for T1 or Fractional T1 services. Data Port rates are selectable via DIP-switches, for
Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers
Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers The Cisco Channelized T1/E1 and ISDN PRI High-Speed WAN Modules combine multiple T1/E1 WAN connectivity-channelized T1/E1
T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router
T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router Cisco integrated services routers offer a wide variety of WAN connectivity modules to accommodate the range of application needs in customer networks.
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Introduction When network managers decide on a cabling system,
Trinity Feature: T1/E1 Configuration
Trinity Feature: Reference Guide Appendix Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: [email protected] WWW: www.patton.com Part Number: 07MTRINT1E1-APD, Rev. C Revised:
DSL - Digital Subscriber Line Installation, Maintenance & Troubleshooting
Hands-On DSL - Digital Subscriber Line Installation, Maintenance & Troubleshooting including: CAT5 & CAT6 Preparation, Installation & Testing BICSI CECs This course has been approved for CEC credits by
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
Loop-IP6700 TDMoEthernet
Loop- Description Loop- is designed to transport /T1/DTE/E3/DS3 signal with timing plus Ethernet traffic over IP network, electrical or optical. This is a cost effective way of migrating to IP network
DXC Family. Multiservice Access Node FEATURES
DXC Family Multiservice Access Node FEATURES Digital cross-connection for up to 30 n x 56/64 kbps or T1/E1 over copper or fiber The modular DXC family includes the following chassis types: DXC-30 with
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks By Galen Udell Belden CDT Networking 2006 Category 6 vs Category 5e Cabling Systems and Implications
Copper Testing for ADSL/2/2+ Qualification and troubleshooting of the local loop
White Paper Copper Testing for ADSL/2/2+ Qualification and troubleshooting of the local loop Summary Today s widespread growth in deployment of higher speed DSL service, such as ADSL/2/2+, enables telecom
CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS
CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS Customer Handout Date Aug 2, 2010 Version 1.0 File Name Customer Requirements At Power Substations Document Id Outside Plant Engineering 1 Table Of Contents 1.0
Network Management System and ICB Management System Software for T1 User s Guide
Telecommunications Group Section 360 381 S02 Equipment Issue 2 Third Printing, October 2006 Network Management System and ICB Management System Software for T1 User s Guide CONTENTS PAGE Part 1. GENERAL.............................................................................
Fundamentals of Telecommunications
Fundamentals of Telecommunications Professor of CIS Columbus, OH 43210 [email protected] http://www.cis.ohio-state.edu/~jain/ 1 Overview Time Division Multiplexing T1, T3, DS1, E1 T1 Framing Echo Cancellation
Cisco Channelized T1/E1 and ISDN PRI Modules
Cisco Channelized T1/E1 and ISDN PRI Modules Product Overview The Cisco Channelized T1/E1 and ISDN PRI High-Speed WAN Modules combine multiple T1/E1 WAN connectivity Channelized T1/E1 and ISDN Primary
TDMoEthernet. Description
Loop-IP6700 TDMoEthernet Description Loop-IP6700 TDMoEthernet is used to transport TDM traffic over IP network, in addition to Ethernet traffic. As the core communications network migrates from TDM to
INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA
COMM.ENG INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA 9/6/2014 LECTURES 1 Objectives To give a background on Communication system components and channels (media) A distinction between analogue
Adaptive Spectrum and Signal Alignment, Incorporated THE RE-PROFILER DSM CLOSES THE CASE ON DIAGNOSING DSL/VDSL TROUBLES
Adaptive Spectrum and Signal Alignment, Incorporated THE RE-PROFILER DSM CLOSES THE CASE ON DIAGNOSING DSL/VDSL TROUBLES PETER J. SILVERMAN - ASSIA INC. FIRST PUBLISHED IN OSP MAGAZINE, SEPTEMBER 2007
EECC694 - Shaaban. Transmission Channel
The Physical Layer: Data Transmission Basics Encode data as energy at the data (information) source and transmit the encoded energy using transmitter hardware: Possible Energy Forms: Electrical, light,
Nexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
T3 Module USER MANUAL. Part Number 1200223L1 / 1200225L1
T3 Module USER MANUAL Part Number 1200223L1 / 1200225L1 61200223L1-1A July 1998 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 (256) 963-8000 1998 ADTRAN, Inc. All Rights Reserved. Printed
Carrier Ethernet: New Game Plan for Media Converters
Introduction IEEE Std. 802.3ah, also referred to as Ethernet in the First Mile (EFM) standard, has a well established name within the industry today. It lays out ground rules for implementing Ethernet