Intel Cloud Builders Guide to Power Management in Cloud Design and Deployment using Supermicro* Platforms and NMView* Management Software
|
|
|
- Madison Hines
- 10 years ago
- Views:
Transcription
1 Intel Cloud Builders Guide Intel Xeon Processor-based Servers Supermicro* Platform and NMView* Management Software Intel Cloud Builders Guide to Power Management in Cloud Design and Deployment using Supermicro* Platforms and NMView* Management Software Supermicro* Platform and NMView* Management Software Intel Xeon Processor 5500 Series Intel Xeon Processor 5600 Series Intel Xeon Processor E Series Audience and Purpose This reference architecture outlines the usage of energy management and thermal technologies as part of planning, provisioning, and optimizing strategies in enterprise and cloud data centers to reduce energy cost and address constrained power situations. It is intended for data center administrators and enterprise IT professionals who seek energy management solutions to achieve better energy efficiency and power capacity utilization within existing or new data centers. The actions and results as prescribed can be used as a reference to understand energy management solutions implemented with the use of hardware and software components. The reader should be able to develop appropriate energy management solutions based on the design options presented using Supermicro* NMView* and Supermicro X8 and X9 servers implementing Intel Power Management technologies. February 2013
2 Table of Contents Executive Summary...3 Introduction...3 Server Power Management...4 Supermicro NMView...4 Supermicro X8 and X9 Servers...5 Supermicro X8 and X9 Supported Systems...5 Intel Node Manager...5 Hardware Requirements...5 Capabilities of Intel Node Manager Technology 1.5 (Supermicro X8)...6 Capabilities of Intel Node Manager Technology 2.0 (Supermicro X9)...6 Intel Xeon E Platform Power Supply Features...6 Intel Closed Loop System Throttling (CLST)...6 Smart Ride Through (SmaRT)...6 Test Bed Blueprint...7 Design Considerations...7 Software Architecture...7 Hardware and Software Description...7 Physical Architecture...8 NMView Console Configuration...9 Initial Settings/Preferences - Adding the License Key to NMView...9 Data Center Hierarchy...11 Scanning and Acquiring Servers...12 Energy Management Use Cases...13 Use Case One: Monitoring Power, Temperature, and Events of a Device or Group...14 Understanding Power and Thermal Data...14 Use Case Two: Creating Power Policies to Increase Server Density...15 Use Case Three: Surviving Power and Thermal Demands in the Data Center...16 Emergency Power Reduction...16 Mitigating Thermal Events...16 Use Case Four: Optimizing Power Usage to Meet Workload and Power Demands...17 Conclusion...18 Things to Consider: Architectural Considerations...18 Scalability...18 Management Traffic Separation...18 Power Management...18 Power Capping Capability in Supermicro NMView...18 System Management Software Suite...18 References
3 Executive Summary The evolution of cloud computing has resulted in highly efficient and carefully optimized data centers with increased server density and capacity that makes considerations on energy consumption and utilization extremely critical along with several other factors that were not as significant in smaller data centers of the past. To support this evolution, Intel works with end users to create an open data center roadmap of usage models that address key IT pain points for more secure, efficient, and simple cloud architectures built on a foundation of transparency. This paper describes an Energy Management Reference Architecture based on Supermicro and Intel solutions with usage models aimed at data center power efficiency and optimal utilization of provisioned power and cooling capacity. The goal of energy management usage models is to optimize productivity per watt in order to reduce total cost of ownership (TCO). Requirements include the capability to monitor and cap power in real-time at server, rack, zone, and data center levels. This means the ability to monitor and manage aggregated power consumption within a rack, zone, or data center based on available power and cooling resources. Intel Node Manager is implemented on Intel server chipsets starting with Intel Xeon processor 5500 and Intel Xeon processor 5600 series platforms. Significant improvements with Intel Node Manager 2.0 being introduced in 2012 on Intel-based Supermicro server platforms supporting the Intel Xeon E5 processor family which are also presented in this document. In this reference architecture we used Supermicro* X8 and X9 servers with Intel Node Manager 1 and Supermicro NMView 2 which uses the Intel Data Center Manager 3 SDK (Intel DCM) to provide data center energy efficiency through real time power monitoring of the servers, power capping and policy based energy management. We describe the following energy management use cases in detail along with experimental results and data. 1. Real-time Server Energy Usage Monitoring, Reporting and Analysis to get continuous and actual energy usage visibility via agentless monitoring of the servers along with other devices and systems in the enterprise network, data center and facilities. The actionable reporting and analysis with real-time power monitoring enables reduction in energy cost and carbon emissions. 2. Power Guard Rail and Optimization of Rack Density by imposing power limits to prevent server power consumption from straying beyond the preset limit. The deterministic power limit and guaranteed server power consumption ceiling helps maximize server count per rack and therefore return on investment of capital expenditure per available rack power when the rack is under power budget with negligible or no per server performance impact. 3. Disaster Recovery/Business Continuity by applying significantly lower power caps to lower power consumption and heat generation when unforeseen circumstances like power outage and cooling system failure occur. In these scenarios it may be appropriate to set aggressively lower power caps, though performance may be affected. The use case illustrates how this works at a data center location or a group of servers. 4. Power Optimized Workloads to achieve power efficiency. Workload profiles are built and a maximum performance loss target is set. Experiments determine how much capping can be applied before the performance target is hit. The approach is to match actual performance against service level requirements. For workloads that were processor intensive, a 10 percent reduction in power savings equated to 13 percent decrease in performance. The paradigm of cloud computing brings opportunity for data center efficiency. Energy management usage models addressed here can substantially help to meet power management requirements. Supermicro NMView can manage a wide range of devices and systems in the data center to reduce energy cost; however, this paper focuses its usage models on servers, specifically Supermicro X8 and X9 servers with Intel power management technologies. Introduction Enterprise data center efficiency has become a central focal point for many industry leaders and all facets of the data center are being scrutinized for efficiency modeling. Components across the data center infrastructure are becoming more power efficient and offering data collection points to give administrators more control of their enterprise environments. Power and thermal data collection of an aggregated group of servers can give data center managers the ability to use this aggregated information to formulate new methods to optimize power usage in the data center while ensuring power levels are met on a real-time basis. Enterprise computing is very demanding and is increasing rack density to new levels. Power and thermal monitoring and control are gaining more importance with each new system that is focused on delivering the best performance per watt per workload. Companies are consistently focusing on 3
4 lowering TCO while still meeting customer demands for increased capability to run more workloads in the data center. The benefit of tuning your workloads to your data center capabilities allows for a solid delivery of services, while ensuring the infrastructure is utilized in the most efficient manner. In the past, data centers were using nameplate values for their servers to gauge how many systems could fit within a rack or circuit, but with the ability to poll data from systems in real time, a data center manager can monitor the actual usage and set a de-rated power limit on those systems which can allow for more server density per circuit. Using de-rate power numbers for data center planning versus the nameplate power can increase rack density by 40 percent. Supermicro X8 and X9 servers support real time monitoring of power consumption using Intel Node Manager. They are managed using Supermicro NMView on a regular basis to ensure the rack power is kept within boundaries, and alert the system admin if power abatement is required to sustain the system service level agreements. Server Power Management In the past, power consumption used to be an afterthought for server deployment in data centers. Unfortunately, this view persists. For example, in many facilities the utility bill is bundled with the overall building charge which reduces the visibility of the data center cost. Even though servers have become much more efficient, packaging densities and net power consumption have increased. As a result, power and its associated thermal characteristics have become the dominant components of operational costs. Power and thermal challenges in data centers include: Increased total operational costs due to increased power and cooling demands. Physical limitations of cooling and power within individual servers, racks, and, data center facilities. Lack of visibility into actual real-time power consumption of servers and racks. Complexity of management components and sub-systems from multiple vendors with incompatible interfaces and management applications. These challenges to manage data centers can be translated into the following requirements: Power monitoring and capping capabilities at all levels of the data center (system, rack identification, and data center). What can be done at an individual server level becomes much more compelling once physical or virtual servers are scaled up significantly. Aggregation of the power consumed at the rack level and management of power within a rack group to ensure that the total power does not exceed the power allocated to a rack. Higher level aggregation and control at the row or data center level to manage the power budget within the average power and cooling resources available. Optimization of productivity per watt through management of power at the server, rack, row, and data center levels to optimize TCO. Application of standards-based power instrumentation solutions available in all servers to allow management for optimal data center efficiency. Extension of instrumentation to enable load balancing or load migration based on power consumption, and close coupled cooling for the management of pooled power and cooling resources. Supermicro NMView NMView is an application used to monitor Supermicro X8 and X9 series servers with Intel Node Manager. It can help data center managers monitor the health of servers in real time and immediately respond when problems arise. Monitored parameters include power, temperatures, policies, and events. NMView authenticates access through the Supermicro Baseboard Management Controller (BMC) which must be configured on each system in the data center that is to be monitored. Supermicro NMView provides real-time power monitoring and management for up to 5,000 servers per instance. NMView can be set up in a tiered architecture where multiple NMView servers can communicate to a master server. Included in the Supermicro X8 and X9 server is the BMC which allows the systems administrator access to monitor power and thermal inlet temperature (X9 series and newer). The BMC is fully featured on the Supermicro X8 and X9 servers including full Intelligent Platform Management Interface (IPMI) support, a graphical interface, as well as full remote KVM with virtual media access. Communication to the servers is performed via TCP/IP and IPMI and no other software or plugins are required for access. The BMC must have IPMI over LAN access with administrator rights in one of the first three cipher suites. This allows out-of-band access from the console to monitor and control each Supermicro X8 and X9 server. Supermicro NMView has been developed to address several imperatives that impact enterprise customers on a daily basis. Worldwide usage of Supermicro high-efficiency solutions could save up to $5.7 billion per year in electricity costs, 57 billion kilowatt-hours per year of electricity or the equivalent of 9 billion trees compared to the servers in use in today's data centers. 4
5 For example, a data center with 1,000 1U high-efficiency servers could save up to $84,000 annually in electricity costs, 700 tons of CO2, or the equivalent of 240 acres of trees for the sequestration of CO2 emissions. 5 The consequences of not managing power can be related to, but are not limited to these examples: Rack density suffers from poor server placement, and no real monitoring has been available. Unpredictable power bills due to no central monitoring capability. The energy provider supplies a bill, but there is no breakdown from the overall power. Brownout or blackout issue causes loss of workloads. If power could be mitigated to reduce load, the work could be sustained to ride through the outage. Stranded power from over-subscribing servers in racks to play it safe and ensure power limits aren t exceeded. All of these issues and more can be addressed by installing NMView along with Supermicro X8 and X9 server systems that utilize Intel Node Manager. Supermicro X8 and X9 Servers Supermicro X8 and X9 servers offer the most advanced technological innovations to give you more capacity to implement workloads and the tools to harness the power while delivering workloads in your data center. Supermicro s IPMI based BMC management deploys, updates, monitors, and maintains the entire server lifecycle, through agent-free out-of-band management. This allows customers to process more data, support more applications, reduce infrastructure complexity, and increase efficiencies without increasing your bottom line costs. To stay innovative, you must quickly adapt to the changing demands of your customers or constituents. And making sure your IT infrastructure keeps pace can be a daunting task. With new Supermicro X8 and X9 servers systems management in your corner, you can spend more time on expanding business and less time struggling to keep your operations up. Supermicro X8 and X9 Supported Systems The Supermicro X9 server boards are available in a variety of architectures including Twin and new Fat Twin, GPU/MIC Supercomputer, MicroCloud, Data Center Optimized, SuperServer* Advantage, I/O Optimized, SuperWorkstation, and SuperStorage Solutions. These Serverboards offer numerous advantages including up to 768GB of Reg. ECC DDR3-1600MHz memory in 24 DIMM slots, SATA 3.0 and SAS 2.0 (6Gb/s) HDD support, ConnectX FDR/QDR InfiniBand ports, dual 10 Gigabit Ethernet, Quad Ethernet LAN, PCI-E 3.0 technology, LSI* 2308 controller with software RAID and LSI* 2208 controller with hardware RAID, IPMI 2.0, and Intel Xeon processor E5-2600/1600 series for highest performance. With New Generation X9 Serverboard Platform Supermicro offers an extensive selection of solutions for data center, Enterprise IT, cloud computing, graphics, technical computing, and HPC environments. 6 Intel Node Manager Intel Node Manager is an individual server power management capability that is embedded in Supermicro X8 and X9 servers. Intel Node Manager is firmware and hardware based technology that is used to optimize and manage power and cooling resources in the data center. This server power management technology extends component instrumentation to the server level and can be used to make the most of every watt consumed in the data center. Intel Node Manager delivers the core capability to provide real-time power and inlet temperature information and can enable power limits to allow the data center to be run in a more efficient manner. Hardware Requirements Intel Chipset (Intel 5520 Chipset for Supermicro X8, and Intel C600 Chipset for Supermicro X9) Intel Manageability Engine (Intel ME) firmware enabled by default by BIOS on Supermicro hardware products (version 1.5 for Supermicro X8, and version 2.0 for Supermicro X9) PMBus* Based Power Supply v1.1 (v1.2 recommended) 7 Baseboard Management Controller (BMC) for communication between the console and Intel ME 5
6 Figure 1: Schematic of Supermicro Server and Basic Level Communication Capabilities of Intel Node Manager Technology 1.5 (Supermicro X8) Report system-level power consumption Limits power via policies defined by the IT Administrator at the system, rack, row, and room level using P and T-State controls Trigger and time based policies Up to 16 policies (stored in Intel ME firmware) per system Capabilities of Intel Node Manager Technology 2.0 (Supermicro X9) In addition to the features found in Node Manager 1.5, additional controls and sensors in the Supermicro X9 platforms include: Runtime Average Power Limiting (RAPL) to implement power control in CPU and memory Report inlet temperature per server CPU domain power monitoring and limiting Memory domain power monitoring and limiting Dynamic core allocation (requires ACPI compliant OS) Intel Xeon E Platform Power Supply Features Intel Node Manager requires the usage of a PMBus (v1.1 or recommended v1.2) based power supply in order to monitor the direct power draw of the overall platform. In addition to this feature on the Intel Xeon E based servers (Supermicro X9), there are additional features that have been built into the platforms to help mitigate cost and increase platform readiness in the datacenter. Intel Closed Loop System Throttling (CLST) Intel Closed Loop System Throttling (CLST) reduces power supply unit (PSU) size and cost, improves PSU efficiency in redundant mode, and allows additional components to be added to the baseboard. A protection mechanism prevents PSU overloading and system crashing when platform power exceeds supported levels, and maintains the highest possible efficiency over the full operating range of system load states. Smart Ride Through (SmaRT) Smart Ride Through (SmaRT) controls the PSU load during AC line dropouts, provides higher PSU efficiency at heavy load times, and simplifies PSU holdup time requirements. This allows the system to ride through momentary losses of AC power while maintaining the highest possible power supply efficiency. 6
7 Test Bed Blueprint Intel and Supermicro collaborated on implementing a test bed that features Supermicro X8 and X9 servers, designed for high-performance and efficiency in enterprise computing. The test bed is intended to provide an environment to simulate the aspects of a data center that are relevant to enterprise computing usage models using Supermicro X8 and X9 Servers which include Intel Node Manager and being managed by Supermicro NMView management using Intel DCM as the base framework for power and thermal management. Design Considerations Supermicro X8 and X9 servers having Intel Node Manager are instrumented with PMBus compliant power supplies required for real-time power monitoring. On the Supermicro X9 platforms the inlet thermal sensor is also utilized for thermal readings and reaction to those readings is triggered via power policies set by the system administrator. Authentication in this document will be used as the Administrator account. More advanced account authentication methods can be reviewed in the Supermicro NMView documentation. Software Architecture Supermicro NMView is based on the Intel DCM SDK and supports a large infrastructure of servers based on a tiering architecture. One master NMView system can control multiple Intel DCM servers each Intel DCM server can manage 5,000 nodes so this gives the customer the capability to grow and expand their datacenter and control power and thermals during the growth and maintenance phase. Figure 2: Schematic of Supermicro NMView Tiered Hierarchy of Monitoring Systems Hardware and Software Description Node System Physical Components BIOS/Firmware Servers 1 thru 4 Server 5 Supermicro 1026T-URF4+ Supermicro SYS- 1027GR-TRF SYS Dual Processor Intel Xeon Processor X5690, 3x500G RAIDS, 12GB RAM Dual Processor Intel Xeon Processor E5-2670, 2x Intel 160G SSD< 64GB RAM, Dual GK104 nvidia BIOS 2.1a, BMC 1.73, Intel ME 1.12 BIOS 1.0c, BMC 1.73, Intel ME
8 Intel Cloud Builders Guide: Supermicro* Platform and NMView* Management Software Physical Architecture The systems in our group testing for this document were housed in a single rack but split across two networks. The VM for NMView and Intel DCM was provided by Supermicro 1026T-URF4 servers running VMware ESX5i with a single virtual NIC on subnet 91, which also had access to subnet 70 via the lab Gigabit network. Figure 3: Hardware Architecture 8
9 NMView Console Configuration VM (hosted on a Supermicro SYS- 1026T-URF4+ running VMware ESX 5.1 server) 40GB disk space 4GB available RAM Single 1GbE virtual NIC 4-Cores x 3.47GHz (Intel Xeon X5670 Processor) OS: Microsoft Windows* Server 2008 R2 x64 IBM J9 VM (build 2.6, JRE Windows Server 2008 R2 amd _ (JIT enabled, AOT enabled) Bundled with NMView Intel DCM Initial Settings/Preferences Adding the License Key to NMView In order to get full functionality of power and thermal monitoring and limiting, the NMView server needs to be licensed for full feature utilization. If the installation does not have a license key, the instance of NMView server is limited to monitoring capabilities. Registration is a simple process to follow in the NMView screen by clicking Help Activation and selecting your method of installation. Shown below is the online activation, but offline modes can be performed as well if your network is secured and does not allow for internet access. Figure 4: Online NMView Activation 9
10 The initial configuration of your server will depend on some key factors depending on your datacenter requirements: Power cost per kwh Cooling/power multiplier (in general, many use 1.5 ratio of cooling in relation to power usage) Level of granularity that you want to monitor we are using 30 seconds in this paper If you have a multiple NMView server installation, this is where you can configure the tiered-architecture we are using a single instance of NMView Server for this paper. Intel DCM has several customization options. The screen capture in Figure 5 shows the options we used in creating this paper. Figure 5: Intel DCM Configuration One 10
11 When starting up NMView for the first time, you ll need to authenticate to the Intel DCM installation. Figure 6 shows our basic configuration for this NMView instance. Figure 6: Basic NMView Configuration You can now double-click on the server name which will open a new frame in the display. This new frame will be the primary window used in this document, showcasing the monitor, policies, events, and logging. Data Center Hierarchy Depending on your data center configuration, you may wish to group systems in various ways physical location, logical grouping, application based grouping, or just simple racks and rows. You can define your NMView/Intel DCM groups as you wish. In this document we are using four Supermicro X8 systems and one Supermicro X9 server, which are denoted in specific racks, rows, room, and overall data center hierarchy. In the next section we will showcase how to add these systems to your NMView hierarchy. Figure 7: Hierarchical Display of the NMView Monitored Systems 11
12 Scanning and Acquiring Servers You can manually add each node to the NMView server using these simple steps: 1. Click New Node and a dialog box will pop up. 2. Input the properties of the node. a. Name, Type, Connector Name, BMC Address, and Derated Power are mandatory fields. b. Continue to add valid values to the rest of the fields as needed. 3. When finished, click the OK button to create the new node. To assist in scale deployment, Supermicro has simplified the process to add systems to NMView by giving the ability to scan subnets with a standard BMC username and password to acquire multiple systems in a simple network scan on your management network. By default, all Supermicro BMC usernames and passwords from the factory are setup as ADMIN for username and ADMIN for the password both are case sensitive. 1. Click New to add a network discovery task and a dialog box will pop up 2. Please select a protocol and type in the IP range, network mask and login information (i.e. ADMIN and ADMIN) 3. Click OK to add the task, and the IP range will be scanned for authentication and added to a list. 4. Click the finished task to show the available devices. 5. Select the available devices. 6. Click Add to add the selected devices as entities. Note: It is recommended to change the username/password combination to add a layer of security once you ve acquired your servers into NMView. It is highly recommended to establish good security practices for authentication. 12
13 Energy Management Use Cases Using intelligent energy management at the server level helps IT administrators squeeze extra value and performance out of existing rack space while reducing the total cost of ownership by better managing power and operational cooling costs. Administrators can improve business continuity by dynamically capping power to avoid overcooling systems, reducing downtime and allowing critical operations to continue even during power or thermal events. They can also balance resources by dynamically moving power from one part of the data center to another, depending on where the need for power or cooling is greatest. To maximize the benefits of Intel Node Manager, a management console is required to aggregate power data and set policies for physical and logical groups of servers. Supermicro NMView is the featured console in this document, and we will detail the resources available to support Intel Node Manager in scale deployment. Establishing policies give the data center administrator the ability to setup certain scenarios to manage these four basic usage models. Group management is utilized in Supermicro NMView via a simple hierarchical display, while controlling multiple servers within the physical (or logical) groups. Establishing boundaries and limits ensures that the server group operates within the guidelines as prescribed by the datacenter manager. Figure 8: Energy Management Use Cases 13
14 Use Case One: Monitoring Power, Temperature, and Events of a Device or Group The most basic use case of monitoring gives us the basis of data to evaluate the systems in the datacenter and make conscious decisions from that data. Data center administrators are expected to have information on rack density, thermal footprint, and overall power consumption on a measured basis across the data center. Supermicro NMView gives simple access to some critical data found in each and every datacenter. By using Intel Node Manger technology in conjunction with the BMC, the data center manager can visually see the power consumed by each server, and the thermal inlet temperature (X9 Series) on the front of each server chassis. These data points can be aggregated to make critical decisions on server placement, manage ways to optimize cooling, and also maximize the usage of power circuits throughout the room. When devices are added into NMView, the data collection process starts immediately and, in our test bed demo, measures power and thermal inlet temperature at 30 second intervals. Any events that occur on the systems will be logged automatically. Understanding Power and Thermal Data There are a multitude of sensors on the Supermicro server platforms that provide data to the NMView console. Many of these sensors provide maximum, average, minimum and instantaneous readings and you can custom tailor your NMView display to showcase what data is important to you at any moment. Primarily this document will discuss average power and thermal inlet temperature monitoring in accordance with the four basic use case models. The Supermicro X9 Server in Figure 9 shows four discrete lines monitored over the past hour. You will notice the dip in measurements at the far left of the graph. When the server was switching between workloads, there were a couple of minutes for that transition. You can see the workload changes from the power curve. Here s a quick review of the info in Figure 9: The light blue line on top is the inlet thermal temperature, in this case showing an average 27C (80F) The light green line is average system power which is 429W (under workload) The pink line is average CPU domain power (both processors are included) which is 199W (on average) The bottom purple line is average memory domain power (all RAM included) which is 22W (on average) The Node Manager 2.0 systems (Supermicro X9 servers) will have more knobs and dials to monitor as stated previously, so you will be able to customize your view per node, group, rack, row, or entire room. Figure 9: Supermicro X9 Server Monitoring Four Power and Thermal Variables 14
15 Use Case Two: Creating Power Policies to Increase Server Density Both types of systems provided by Supermicro came with dual PMBus based power supplies (PSUs). These were setup in a redundant mode where if one PSU fails, the second PSU can take the load of the system without worry of failure. On the X8 systems, each PSU is rated at 750W (nameplate value) and the X9 system is rated at 1,800W (nameplate) per PSU. Data center administrators usually understand that the nameplate value printed on the PSU is usually a worst case scenario, but without solid measurement or monitoring many administrators are restrained by overpopulating the data center circuits because the nameplate value is utilized when building racks and planning for power. With the five systems we have available the nameplate total value is 4,800 watts. Now with the nodes added to NMView, it s easy to measure the power consumption in real-time and when all five systems are under workload we show that all five systems are only using 1,372W of power that s 3,428W of power left stranded on the data center floor. Note that the workloads on the test bed may differ from your datacenter so it s good to measure workloads that are pertinent to your customer loads. We can safely add more density to this circuit. Given the data above, the average power consumption per server is 274 watts. If we take 4,800 watts as the maximum available on our power circuit divided by 274 watts per server, we could safely place 17 systems in the same power footprint where we would normally only have five servers in the same 4,800W footprint. This is an increase of 3.4X in the number of servers that could be placed in this rack. Figure 10: NMView Screenshot of Six Systems Power Load at 1,538W (Average) 15
16 Use Case Three: Surviving Power and Thermal Demands in the Data Center Emergency Power Reduction Occasionally we hear from customers who have experienced brown-outs or rolling black outs from their power providers due to over-strained power grids, and running on battery and/or generator backup power is very costly. Supermicro platforms have Intel Node Manager technology which allows for throttling back system power to sustain workloads while reducing power to as low as technically possible while still performing a workload. In many high-performance compute (HPC) instances, the workloads run for a very long time, sometimes many days. In the event that the public service provider either asks for a reduction in power or has an outage, it can drop thousands of hours of compute cycles if the workloads do not finish prior to that event. This is where a Minimum Power Cap can be placed on a group of systems. In this example, we used BOINC ( boinc.berkeley.edu) which is an opensource software platform for volunteer computing and desktop Grid computing. It has a very simple CPU benchmark that can tell you how many Dhrystone MIPS (Integer based Millions of Instruction per Second) your CPU is capable of handling and when power limited it shows a limited response. During the minimum (or emergency) power reduction we experienced a great than 45 percent decrease in power, but also take into account that we had approximately 96 percent impact to The Supermicro X9DRG-HF server showcased the following under test: Supermicro X9DRG-HF MIPS Watts 100% Workload (Uncapped) Minimum Power workload (MIPS). The big difference in comparison to a brownout or power-off situation is that if the power issue is mitigated, the workload is not lost as we see in Figure 11 below. If all power (and resulting MIPS) are lost, it results in zero work being done. Also, take into account that if servers are not gracefully shut down, you have the potential for hardware failure and lost workloads, and there will be some recovery time to set up the workloads again. Mitigating Thermal Events In the event that your data center has a thermal issue or HVAC failure, Intel Node Manager gives you the controls to react to a thermal event. The inlet temperature sensor on the Supermicro X9 systems are continually measuring inlet temperatures and reporting back to the NMView console. In the event that the temperature rises to a pre-set value that the data center administrator deems dangerous, a policy trigger will throttle the systems back to minimum power (like the prior example). This is important because it will do a few things: 1. Give the data center administrator(s) time to mitigate the thermal issue to reduce the rising temperatures. 2. Reduce the power consumed by each server, thereby reducing the heat output from each system which can contribute to the thermal issue that is already occurring in the room. 3. Since the policy is stored on each system and is controlled from the central console, reaction to the thermal emergency is a near instant reaction to the temperature rise. 4. Once the temperature is lowered, the systems will report back to the console which will remove the thermal trigger policy and operation will return to normal. Figure 11: Workload Survives Power-Off Situation 16
17 Use Case Four: Optimizing Power Usage to Meet Workload and Power Demands The fourth use case is the most advanced model, where we have to understand the workload and impacts of limiting power in relation to the performance provided for the given workload. Each application can react differently and should be measured against a known set of metrics to ensure the service delivered by the systems still meets or exceeds your customer s service agreement. Workloads differ for each customer and the workload in this paper is very CPU intensive. Some workloads may have more I/O dependencies or not be as intensive as a CPU benchmark shown in this paper. The data shown in the table below illustrates the impact of power limiting on CPU performance. The CPU intensive workload is impacted by only 13 percent when a 10 percent power limit is incurred. Depending on the workloads in your data center, this may be a feasible solution to save power and also provide 87 percent CPU utilization to your customer base. The graph (MIPS vs. Power) in Figure 12 helps to display the workload to the wattage used by the platform, and the MIPS benchmark runs in a linear fashion in accordance to the power limit imposed on the system. This can help you to monitor your own workloads in real-time to help determine the optimal workload to power ratio. This gives the data center administrator the capability to reduce power usage and still provide the CPU cycles needed to ensure customer satisfaction. Supermicro SYS-1027GR-TRF MIPS Delta from Max CPU Watts 100% % % Power % % Power % % Power % % Power Limit % 236 Min Power 119 4% 209 Figure 12: MIPS vs. Power (W) per Power Limit One 17
18 Conclusion As shown in this document, Supermicro NMView utilizing Intel DCM provides a rich management console to monitor and manage power in the datacenter. Supermicro X8 and X9 servers with embedded Intel Node Manager give the appropriate dials and knobs to custom tune your workload demands to meet customer needs. Automation in server policies also gives assured management during times of crisis in the data center, whether it s a high-temperature situation or simple time-based policy to meet regional power requirements. The four use cases of monitor, limit, survive, and optimize are a superset of usage models in the data center that can be expanded to meet the power and workload requirements to mitigate energy costs and meet compute demands of the datac enter. Things to Consider - Architectural Considerations Scalability A single installation of Supermicro NMView can support up to 5,000 nodes. For larger implementations, multiple instantiations or a tiered installation would be required. Management Traffic Separation Many customers feel a need to separate their management data from their production data. The Supermicro BMC port allows you to put your management data onto a separate network port. The reader should consider options to share the same network or use a separate network, and IP space for the management data. Power Management Usage of power management should be considered only after careful analysis of the workload performance under various conditions and evaluated both before and after power capping has been used. As mentioned previously, there are many usage models that can benefit from power monitoring and management. At the same time, there can be scenarios where power management may not be the optimal solution. For example, if a highly sensitive production application is very CPU intensive and the host machine is already over-subscribed for power, adding a power cap below that maximum power consumption level could inadvertently affect the performance of the system and return less than expected results from the application. Power Capping Capability in Supermicro NMView Basic Supermicro NMView gives you monitoring-only capabilities for power and temperature, but you should upgrade to the license model to implement policies on the server platform. For more details on acquiring the license required, visit System Management Software Suite Supermicro Data Center Management Software Suite, which includes NMView as discussed in this paper, enables the data center operator to manage large clusters remotely and help build a cloud solution that monitors hardware health, provision hardware configuration, and upgrade BIOS and firmware revisions of the servers. Contact your local Supermicro sales representative for further information. References 1. Intel Node Manager: intel.com/technology/nodemanager 2. Supermicro* NMView*: supermicro.com/products/nfo/ nmview.cfm 3. Intel Data Center Manager 4. Intelligent Platform Management Interface (IPMI): com/design/servers/ipmi/ 5. Supermicro Green IT: supermicro.com/greenit/ 6. The updated list of Intel Node Manager supported systems from Supermicro can be found here: nmview.cfm 7. PMBus*: 8. Advanced Configuration and Power Interface (ACPI): To learn more about deployment of cloud solutions, visit cloudbuilders. 18
19 Disclaimers Intel processor numbers are not a measure of performance. Processor numbers differentiate features within each processor family, not across different processor families. See products/processor_number for details. INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined. Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information. The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling , or by visiting Intel s Web site at Copyright 2013 Intel Corporation. All rights reserved. Intel, the Intel logo, Xeon, Xeon inside, and Intel Intelligent Power Node Manager are trademarks of Intel Corporation in the U.S. and other countries. *Other names and brands may be claimed as the property of others.
Intel Cloud Builders Guide for Power Management in Cloud Design and Deployment using Supermicro Platforms and NMView management software
Intel Cloud Builders Guide Intel Xeon Processor based Servers Supermicro* NMView* Intel Cloud Builders Guide for Power Management in Cloud Design and Deployment using Supermicro Platforms and NMView management
Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms
Intel Cloud Builders Guide Intel Xeon Processor-based Servers Dell* OpenManage* Power Center Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms Dell* OpenManage* Power Center
Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms
EXECUTIVE SUMMARY Intel Cloud Builder Guide Intel Xeon Processor-based Servers Red Hat* Cloud Foundations Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms Red Hat* Cloud Foundations
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent
Intel Data Center Manager. Data center IT agility and control
Intel Data Center Manager Data center IT agility and control The Data Center Ecosystem 2 Why do we care about Data Center Management? attributed to devices connected to the Internet of Everything (up from
Preserving Performance While Saving Power Using Intel Intelligent Power Node Manager and Intel Data Center Manager
WHITE PAPER Intel Intelligent Power Node Manager Intel Data Center Manager Data Center Power Management Preserving Performance While Saving Power Using Intel Intelligent Power Node Manager and Intel Data
Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide
Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms
Intel Cloud Builders Guide Intel Xeon Processor-based Servers RES Virtual Desktop Extender Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms Client Aware Cloud with RES Virtual
Intel Service Assurance Administrator. Product Overview
Intel Service Assurance Administrator Product Overview Running Enterprise Workloads in the Cloud Enterprise IT wants to Start a private cloud initiative to service internal enterprise customers Find an
Monthly Specification Update
Monthly Specification Update Intel Server Board S1400FP Family August, 2013 Enterprise Platforms and Services Marketing Enterprise Platforms and Services Marketing Monthly Specification Update Revision
Intel Solid-State Drives Increase Productivity of Product Design and Simulation
WHITE PAPER Intel Solid-State Drives Increase Productivity of Product Design and Simulation Intel Solid-State Drives Increase Productivity of Product Design and Simulation A study of how Intel Solid-State
Cloud based Holdfast Electronic Sports Game Platform
Case Study Cloud based Holdfast Electronic Sports Game Platform Intel and Holdfast work together to upgrade Holdfast Electronic Sports Game Platform with cloud technology Background Shanghai Holdfast Online
Intelligent Power Optimization for Higher Server Density Racks
Intelligent Power Optimization for Higher Server Density Racks A Baidu* Case Study with Intel Intelligent Power Technology White Paper Digital Enterprise Group Q1 2008 Intel Corporation Executive Summary
Intel Active Management Technology Embedded Host-based Configuration in Intelligent Systems
WHITE PAPER Intel vpro Technology Embedded Host-based Configuration in Intelligent Systems Easy activation of Intel vpro technology remote manageability without trade-offs in security, functionality, and
How High Temperature Data Centers and Intel Technologies Decrease Operating Costs
Intel Intelligent Management How High Temperature Data Centers and Intel Technologies Decrease Operating Costs and cooling savings through the use of Intel s Platforms and Intelligent Management features
How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1
How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1 Technical Brief v1.0 February 2013 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED
Intel Ethernet Switch Load Balancing System Design Using Advanced Features in Intel Ethernet Switch Family
Intel Ethernet Switch Load Balancing System Design Using Advanced Features in Intel Ethernet Switch Family White Paper June, 2008 Legal INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL
Intel Cloud Builder Guide to Cloud Design and Deployment on Intel Xeon Processor-based Platforms
Intel Cloud Builder Guide to Cloud Design and Deployment on Intel Xeon Processor-based Platforms Enomaly Elastic Computing Platform, * Service Provider Edition Executive Summary Intel Cloud Builder Guide
FatTwin. 16% Lower Power Consumption 30% More Storage Capacity. Evolutionary 4U Twin Architecture. 4 Nodes in 4U 8 Hot-swap 3.
FatTwin Evolutionary 4U Twin Architecture 16% Lower Power Consumption 30% More Storage Capacity 4 Nodes in 4U 8 Hot-swap 3.5 HDDs per 1U 8 Nodes in 4U 6 Hot-swap 2.5 HDDs per ½U Optimized Design for Data
Intel Data Direct I/O Technology (Intel DDIO): A Primer >
Intel Data Direct I/O Technology (Intel DDIO): A Primer > Technical Brief February 2012 Revision 1.0 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
Intel RAID Controllers
Intel RAID Controllers Best Practices White Paper April, 2008 Enterprise Platforms and Services Division - Marketing Revision History Date Revision Number April, 2008 1.0 Initial release. Modifications
Evaluating Intel Virtualization Technology FlexMigration with Multi-generation Intel Multi-core and Intel Dual-core Xeon Processors.
Evaluating Intel Virtualization Technology FlexMigration with Multi-generation Intel Multi-core and Intel Dual-core Xeon Processors. Executive Summary: In today s data centers, live migration is a required
Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008
Best Practices Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008 Installation and Configuration Guide 2010 LSI Corporation August 13, 2010
Configuring RAID for Optimal Performance
Configuring RAID for Optimal Performance Intel RAID Controller SRCSASJV Intel RAID Controller SRCSASRB Intel RAID Controller SRCSASBB8I Intel RAID Controller SRCSASLS4I Intel RAID Controller SRCSATAWB
Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team
Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture Dell Compellent Product Specialist Team THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL
Windows Server 2008 R2 Hyper-V Live Migration
Windows Server 2008 R2 Hyper-V Live Migration White Paper Published: August 09 This is a preliminary document and may be changed substantially prior to final commercial release of the software described
Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms
IT@Intel White Paper Intel IT IT Best Practices: Data Center Solutions Server Virtualization August 2010 Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms Executive
System Management Software Suite
IPMI Utilities SUM SCM SPM SSM Optimized for Data Centers ly manage servers deployed across globe Manage hardware with no impact to applications Integrate utilities easily with existing infrastructure
Model Manage Monitor Maximize your Data Center
NetZoomDC is the most feature rich, fully-scalable, enterprise Data Center Infrastructure Management (DCIM) software application. It enables data center professionals to Model, Manage, Monitor and Maximize
Different NFV/SDN Solutions for Telecoms and Enterprise Cloud
Solution Brief Artesyn Embedded Technologies* Telecom Solutions Intel Xeon Processors Different NFV/SDN Solutions for Telecoms and Enterprise Cloud Networking solutions from Artesyn Embedded Technologies*
DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION
DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION A DIABLO WHITE PAPER AUGUST 2014 Ricky Trigalo Director of Business Development Virtualization, Diablo Technologies
Intel Network Builders: Lanner and Intel Building the Best Network Security Platforms
Solution Brief Intel Xeon Processors Lanner Intel Network Builders: Lanner and Intel Building the Best Network Security Platforms Internet usage continues to rapidly expand and evolve, and with it network
Leading Virtualization 2.0
Leading Virtualization 2.0 How Intel is driving virtualization beyond consolidation into a solution for maximizing business agility within the enterprise White Paper Intel Virtualization Technology (Intel
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems
Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems Applied Technology Abstract By migrating VMware virtual machines from one physical environment to another, VMware VMotion can
Affordable Building Automation System Enabled by the Internet of Things (IoT)
Solution Blueprint Internet of Things (IoT) Affordable Building Automation System Enabled by the Internet of Things (IoT) HCL Technologies* uses an Intel-based intelligent gateway to deliver a powerful,
StarWind iscsi SAN: Configuring Global Deduplication May 2012
StarWind iscsi SAN: Configuring Global Deduplication May 2012 TRADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software that may be registered
iscsi Quick-Connect Guide for Red Hat Linux
iscsi Quick-Connect Guide for Red Hat Linux A supplement for Network Administrators The Intel Networking Division Revision 1.0 March 2013 Legal INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
Intel Simple Network Management Protocol (SNMP) Subagent v6.0
Intel Simple Network Management Protocol (SNMP) Subagent v6.0 User Guide March 2013 ii Intel SNMP Subagent User s Guide Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL
Cloud Design and Deployment on Intel Xeon Processor-based Platforms
Intel Cloud Builders Guide Intel Xeon Processor-based Servers Huawei SingleCLOUD* Case Study Cloud Design and Deployment on Intel Xeon Processor-based Platforms Huawei SingleCLOUD* AUDIENCE AND PURPOSE
Monitor the Cisco Unified Computing System
Monitor the Cisco Unified Computing System Using Sentry Software Monitoring for BMC ProactiveNet Performance Management White Paper September 2010 August 2010 Contents What You Will Learn... 3 Overview...
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment
The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment Introduction... 2 Virtualization addresses key challenges facing IT today... 2 Introducing Virtuozzo... 2 A virtualized environment
IT@Intel. Comparing Multi-Core Processors for Server Virtualization
White Paper Intel Information Technology Computer Manufacturing Server Virtualization Comparing Multi-Core Processors for Server Virtualization Intel IT tested servers based on select Intel multi-core
Accelerating Business Intelligence with Large-Scale System Memory
Accelerating Business Intelligence with Large-Scale System Memory A Proof of Concept by Intel, Samsung, and SAP Executive Summary Real-time business intelligence (BI) plays a vital role in driving competitiveness
The Case for Rack Scale Architecture
The Case for Rack Scale Architecture An introduction to the next generation of Software Defined Infrastructure Intel Data Center Group Pooled System Top of Rack Switch POD Manager Network CPU/Memory Storage
Creating Overlay Networks Using Intel Ethernet Converged Network Adapters
Creating Overlay Networks Using Intel Ethernet Converged Network Adapters Technical Brief Networking Division (ND) August 2013 Revision 1.0 LEGAL INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION
with PKI Use Case Guide
Intel Identity Protection Technology (Intel IPT) with PKI Use Case Guide Version 1.0 Document Release Date: February 29, 2012 Intel IPT with PKI Use Case Guide i Legal Notices and Disclaimers INFORMATION
Microsoft Exchange Solutions on VMware
Design and Sizing Examples: Microsoft Exchange Solutions on VMware Page 1 of 19 Contents 1. Introduction... 3 1.1. Overview... 3 1.2. Benefits of Running Exchange Server 2007 on VMware Infrastructure 3...
Monthly Specification Update
Intel Server Board S1200BTLR Intel Server Board S1200BTSR Intel Server Board S1200BTLRM Intel Server System R1304BTLSFANR Intel Server System R1304BTSSFANR Intel Server System R1304BTLSHBNR Intel Server
NFV Reference Platform in Telefónica: Bringing Lab Experience to Real Deployments
Solution Brief Telefonica NFV Reference Platform Intel Xeon Processors NFV Reference Platform in Telefónica: Bringing Lab Experience to Real Deployments Summary This paper reviews Telefónica s vision and
Power and Cooling Innovations in Dell PowerEdge Servers
Power and Cooling Innovations in Dell PowerEdge Servers This technical white paper describes the Dell Energy Smart Architecture and the new and enhanced features designed into Dell PowerEdge 12 th generation
VXRACK SYSTEM 1032. Product Overview DATA SHEET
vce.com DATA SHEET VXRACK SYSTEM 1032 Product Overview VCE adds rackscale hyper-converged offerings to the industry s broadest converged infrastructure system portfolio. The VxRack System 1000 series is
IBM PureFlex System. The infrastructure system with integrated expertise
IBM PureFlex System The infrastructure system with integrated expertise 2 IBM PureFlex System IT is moving to the strategic center of business Over the last 100 years information technology has moved from
Accelerating High-Speed Networking with Intel I/O Acceleration Technology
White Paper Intel I/O Acceleration Technology Accelerating High-Speed Networking with Intel I/O Acceleration Technology The emergence of multi-gigabit Ethernet allows data centers to adapt to the increasing
Intel Management Engine BIOS Extension (Intel MEBX) User s Guide
Intel Management Engine BIOS Extension (Intel MEBX) User s Guide User s Guide For systems based on Intel B75 Chipset August 2012 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U
Twin Servers Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U New Generation TwinPro Systems SAS 3.0 (12Gbps) Up to 12 HDDs/Node FDR(56Gbps)/QDR InfiniBand 1TB DDR3 up to 1866 MHz in 16 DIMMs Redundant
Virtual Appliance Setup Guide
The Virtual Appliance includes the same powerful technology and simple Web based user interface found on the Barracuda Web Application Firewall hardware appliance. It is designed for easy deployment on
The Efficient Data Center
WHITE PAPER Data Center Efficiency and Optimization Data Center Management The Efficient Data Center Using data center instrumentation and server refresh to optimize compute performance in constrained
Introduction to Virtual Datacenter
Oracle Enterprise Manager Ops Center Configuring a Virtual Datacenter 12c Release 1 (12.1.1.0.0) E27347-01 June 2012 This guide provides an end-to-end example for how to use Oracle Enterprise Manager Ops
Juniper Networks QFabric: Scaling for the Modern Data Center
Juniper Networks QFabric: Scaling for the Modern Data Center Executive Summary The modern data center has undergone a series of changes that have significantly impacted business operations. Applications
Supermicro Server Management Utilities
Supermicro IPMI Utilities SuperDoctor 5 SPM SUM SCM Optimized for Data Centers ly manage servers deployed worldwide Manage hardware with no impact on applications Integrate utilities easily with existing
Accelerating Business Intelligence with Large-Scale System Memory
Accelerating Business Intelligence with Large-Scale System Memory A Proof of Concept by Intel, Samsung, and SAP Executive Summary Real-time business intelligence (BI) plays a vital role in driving competitiveness
Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms
Intel Cloud Builders Guide Intel Xeon Processor-based Servers NTT DATA BIZXAAS* Full OSS Cloud Solution Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms NTT DATA BIZXAAS* Full
Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays
Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays Database Solutions Engineering By Murali Krishnan.K Dell Product Group October 2009
Intel Matrix Storage Console
Intel Matrix Storage Console Reference Content January 2010 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,
Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell
Solve your IT energy crisis WITH AN ENERGY SMART SOLUTION FROM DELL overcome DATA center energy challenges IT managers share a common and pressing problem: how to reduce energy consumption and cost without
This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.
Installation Guide This guide explains how to install an (Intel SSD) in a SATA-based desktop or notebook computer. The instructions include migrating your data from your current storage device (such as
What s New with VMware Virtual Infrastructure
What s New with VMware Virtual Infrastructure Virtualization: Industry-Standard Way of Computing Early Adoption Mainstreaming Standardization Test & Development Server Consolidation Infrastructure Management
A Superior Hardware Platform for Server Virtualization
A Superior Hardware Platform for Server Virtualization Improving Data Center Flexibility, Performance and TCO with Technology Brief Server Virtualization Server virtualization is helping IT organizations
Kronos Workforce Central on VMware Virtual Infrastructure
Kronos Workforce Central on VMware Virtual Infrastructure June 2010 VALIDATION TEST REPORT Legal Notice 2010 VMware, Inc., Kronos Incorporated. All rights reserved. VMware is a registered trademark or
Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms
Intel Cloud Builders Guide Intel Xeon Processor-based Servers Power Management & Security within Open Source Private Cloud with Intel & OpenStack Intel Cloud Builders Guide to Cloud Design and Deployment
Why ClearCube Technology for VDI?
Why ClearCube Technology for VDI? January 2014 2014 ClearCube Technology, Inc. All Rights Reserved 1 Why ClearCube for VDI? There are many VDI platforms to choose from. Some have evolved inefficiently
Maximize Performance and Scalability of RADIOSS* Structural Analysis Software on Intel Xeon Processor E7 v2 Family-Based Platforms
Maximize Performance and Scalability of RADIOSS* Structural Analysis Software on Family-Based Platforms Executive Summary Complex simulations of structural and systems performance, such as car crash simulations,
Using Multi-Port Intel Ethernet Server Adapters to Optimize Server Virtualization
White Paper Intel Ethernet Multi-Port Server Adapters Using Multi-Port Intel Ethernet Server Adapters to Optimize Server Virtualization Introduction As enterprise-class server infrastructures adopt virtualization
Windows Server 2008 R2 Hyper-V Live Migration
Windows Server 2008 R2 Hyper-V Live Migration Table of Contents Overview of Windows Server 2008 R2 Hyper-V Features... 3 Dynamic VM storage... 3 Enhanced Processor Support... 3 Enhanced Networking Support...
Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis
White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This document
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System with Internal Storage Focusing on IPMI Out of Band Management Recipe ID: 19SYAM190000000011-01 Contents Hardware Components...3
10GBASE-T for Broad 10 Gigabit Adoption in the Data Center
WHITE PAPER 10GBASE-T Ethernet Network Connectivity 10GBASE-T for Broad 10 Gigabit Adoption in the Data Center The increasing use of virtualization and unified networking places extreme I/O demands on
Intel RAID RS25 Series Performance
PERFORMANCE BRIEF Intel RAID RS25 Series Intel RAID RS25 Series Performance including Intel RAID Controllers RS25DB080 & PERFORMANCE SUMMARY Measured IOPS surpass 200,000 IOPS When used with Intel RAID
Intel Media SDK Library Distribution and Dispatching Process
Intel Media SDK Library Distribution and Dispatching Process Overview Dispatching Procedure Software Libraries Platform-Specific Libraries Legal Information Overview This document describes the Intel Media
COSBench: A benchmark Tool for Cloud Object Storage Services. [email protected] 2012.10
COSBench: A benchmark Tool for Cloud Object Storage Services [email protected] 2012.10 Updated June 2012 Self introduction COSBench Introduction Agenda Case Study to evaluate OpenStack* swift performance
LOAD BALANCING 2X APPLICATIONSERVER XG SECURE CLIENT GATEWAYS THROUGH MICROSOFT NETWORK LOAD BALANCING
SECURE CLIENT GATEWAYS THROUGH MICROSOFT NETWORK LOAD BALANCING Contents Introduction... 3 Network Diagram... 3 Installing NLB... 3-4 Configuring NLB... 4-8 Configuring 2X Secure Client Gateway... 9 About
EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter
EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, VMware vcenter Converter A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper
Taking Virtualization
Taking Virtualization to the SMB Market How Lenovo is driving Virtualization solutions for the SMB market by lowering costs and simplifying deployment White Paper Lenovo Virtualization Solutions Introduction
Intel Open Network Platform Release 2.1: Driving Network Transformation
data sheet Intel Open Network Platform Release 2.1: Driving Network Transformation This new release of the Intel Open Network Platform () introduces added functionality, enhanced performance, and greater
Management of VMware ESXi. on HP ProLiant Servers
Management of VMware ESXi on W H I T E P A P E R Table of Contents Introduction................................................................ 3 HP Systems Insight Manager.................................................
HUAWEI Tecal E6000 Blade Server
HUAWEI Tecal E6000 Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The HUAWEI Tecal E6000 is a new-generation server platform that guarantees comprehensive and powerful
High-Performance Computing Clusters
High-Performance Computing Clusters 7401 Round Pond Road North Syracuse, NY 13212 Ph: 800.227.3432 Fx: 315.433.0945 www.nexlink.com What Is a Cluster? There are several types of clusters and the only constant
LANDesk White Paper. LANDesk Management Suite for Lenovo Secure Managed Client
LANDesk White Paper LANDesk Management Suite for Lenovo Secure Managed Client Introduction The Lenovo Secure Managed Client (SMC) leverages the speed of modern networks and the reliability of RAID-enabled
HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN
HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN Table of contents Executive summary... 2 Introduction... 2 Solution criteria... 3 Hyper-V guest machine configurations...
Upgrading Data Center Network Architecture to 10 Gigabit Ethernet
Intel IT IT Best Practices Data Centers January 2011 Upgrading Data Center Network Architecture to 10 Gigabit Ethernet Executive Overview Upgrading our network architecture will optimize our data center
Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure
White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This
MS Exchange Server Acceleration
White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba
Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V. Technical Brief v1.
Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V Technical Brief v1.0 September 2012 2 Intel Ethernet and Configuring SR-IOV on Windows*
Lenovo Partner Pack for System Center Operations Manager
Lenovo Partner Pack for System Center Operations Manager Lenovo Enterprise Product Group Version 1.0 December 2013 2013 Lenovo. All rights reserved. Legal Disclaimers: First paragraph is required. Trademark