Intelligent Power Optimization for Higher Server Density Racks
|
|
|
- Mervyn Montgomery
- 10 years ago
- Views:
Transcription
1 Intelligent Power Optimization for Higher Server Density Racks A Baidu* Case Study with Intel Intelligent Power Technology White Paper Digital Enterprise Group Q Intel Corporation Executive Summary Intel partnered with Baidu.com* and conducted a proof of concept (PoC) project using the Intel Intelligent Power Node Manager (Node Manager) and Intel Data Center Manager to intelligently optimize server performance and power consumption to optimize server density. The engineers implementing the PoC used Node Manager to identify optimal control points, which became the basis to define node level power optimization policies. Intel Data Center Manager (Data Center Manager) Reference Graphical User Interface was used to manage servers as a group to carry out rack power policies while minimizing performance impact of all the managed nodes in the rack. The policies enable increasing rack density and workload yield even when the whole rack is subject to power limitations. The PoC was conducted initially on site at Baidu in Q at Intel-Baidu joint lab with a configuration close to production configurations running Baidu search workloads. The runs in the first round were carried out with Bensley generation platforms. An updated set of runs was carried out in Q using pre-production units with the more advanced Nehalem platform. The test servers used were provisioned with dual X5560 processors. These processors feature eleven ACPI p-states, allowing the frequency to vary from 2.8 GHz to 1.6 GHz instead of the three states available in the Bensley generation. The additional p-states allow finer grained power control and an expanded power dynamic range. Here are some global results: For the Bensley generation it was possible to trim power consumption by 40 W running the Baidu search workload while staying within the acceptable performance boundaries determined by Baidu. For the Nehalem platform the range has been expanded to 70 watts, allowing Baidu increased operational flexibility. At rack level, up to 20% additional capacity increase could be achieved within the same rack-level power envelope when aggregated optimal power management policy is applied Comparing with today s datacenter operation at Baidu, by using Intel Node Manager and Intel Data Center Manager, there could be a rack density increase from 5 to 7/8 servers a 40%+ improvement
2 Table of Contents 1. Business Overview Top Business Issues 4 2. Intel Technology and Solution Intel Intelligent Power Node Manager (Node Manager) Intel Data Center Manager (Data Center Manager) 5 3. POC Use Cases 5 4. POC Architecture 6 5. POC Results 7 6. Conclusion 8 2
3 1. Business Overview Baidu is the largest search company in China, accounting for over 60% of search market share in China. Its market share in the Chinese domestic market has grown steadily in the past few years. Baidu s reach extends to international markets, with established branch offices in Japan, the U.S. and other countries. Currently Baidu uses China Telecom* as its data center hosting provider. Baidu is billed by the rack. Each rack comes with strict power limits of no more than 10 A per rack or 2.2 KW at 220 V. Because racks are currently power limited, a significant amount of rack space can t be used without hitting power envelope limits. Since Baidu is also billed by the rack, Baidu is highly motivated to maximize the number of servers per rack while staying within the 10 A current limit. As Baidu grows, the company will eventually operate company-owned data centers. Given their previous experience, power consumption remains one of the top platform management concerns, and is not expected to abate even with company operated data centers. Figure 1: Baidu.com Search Portal 3
4 1.1 Top Business Issues As mentioned above, data center hosting represents a major operational cost for Baidu, costs being proportional to the number of racks leased from China Telecom. Power constraints limit the number of servers that can be placed in a rack, and a significant amount of space goes unused and wasted. An easy way to increase the compute yield is to tightly manage the number of servers within the power envelope. Unfortunately currently there is no accurate means to measure power consumption against the power limit. Hooking a power meter would only give a snapshot in time in what is a very dynamic environment. The closest data would be using a derated nameplate figure. This figure is still overly conservative because it needs to account for the worst case in power consumption. In other words, there is no dynamic power management technology which allows Baidu to optimize power utilization. To summarize, Baidu is facing the following power management challenges: Over-allocation of power: Power allocation to servers does not match actual server power consumption. Power is typically allocated for worst case scenario based on server nameplate. Static allocation of power budget based on worst case scenario leads to inefficiencies and does not maximize use of available power capacity and rack space. Under-population of rack space: As a direct result of the over-allocation problem, there is a lot of empty space on racks. When Baidu needs more compute capacity, they have to pay more for additional racks. China Telecom on the other hand, is operating at capacity and Baidu has leased most of the available racks in Beijing. Available datacenter space is limiting factor to Baidu s business growth. Capacity planning: Baidu does not have means to forecast and optimize power and performance dynamically at rack level. To improve power utilization, datacenters needs to track actual power and cooling consumption and dynamically adjust workload and power distribution for optimal performance at rack and datacenter levels. 2. Intel Technology and Solution 2.1 Intel Intelligent Power Node Manager (Node Manager) Node Manager is an out-of-band (OOB) power management policy engine embedded in Intel server chipsets. Processors carry the capability to regulate their power consumption through the manipulation of the P- and T-states. Node Manager works with the BIOS and OS power management (OSPM) to perform this manipulation and dynamically adjust platform power to achieve maximum performance and power for a single node. Node Manager has the following features: Dynamic Power Monitoring: Measures actual power consumption of a server platform within acceptable error margin of +/- 10%. Node Manager gathers information from PSMI instrumented power supplies, provides real-time power consumption data singly or as a time series, and reports through IPMI interface. Platform Power Capping: Sets platform power to a targeted power budget while maintaining maximum performance for the given power level. Node Manager receives power policy from an external management console through IPMI interface and maintains power at targeted level by dynamically adjusting CPU p-states. Power Threshold Alerting: Node Manager monitors platform power against targeted power budget. When the target power budget cannot be maintained, Node Manager sends out alerts to the management console. 4
5 2.2 Intel Data Center Manager (Data Center Manager) Intel Data Center Manager is software technology that provides power and thermal monitoring and management for servers, racks and groups of servers in datacenters. It builds on Intel Intelligent Power Node Manager and customers existing management consoles to bring platform power efficiency to End Users. Data Center Manager implements group level policies that aggregate node data across the entire rack or data center to track metrics, historical data and provide alerts to IT managers. This allows IT managers to establish group level power policies to limit consumption while dynamically adapting to changing server loads. The wealth of data and control that Data Center Manager provides allows data centers to increase rack density, manage power peaks, and right size the power and cooling infrastructure. It is a software development kit (SDK) designed to plug-in to software management console products. It also has a reference user interface which was used in this POC as proxy for a management software product. Key Intel Data Center Manager features are: Group (server, rack, row, PDU and logical group) level monitoring and aggregation of power and thermals Log and query for trend data for up to one year Policy driven intelligent group power capping User defined group level power alerts and notifications Support of distributed architectures (across multiple racks) 3. POC Use Cases In this POC we focused on use cases to test Node Manager features at node level first. A baseline test is needed to identify the optimal control points at the node level for Baidu search workload. We then used these optimal control points as the base for rack level policy definition. A summary of use cases is listed below: Use Case Title Description Get power consumption Using the Intel Node Manager features to dynamically gather point in time power consumption from on each server each server on the rack Estimate total power Estimate rack level power consumption by summing up node level power consumption; display on, and consumption of a rack notify console as appropriate Optimize rack level policy At rack level, analyze the power consumption of each server, overall power consumption, rack level within a given power envelop power envelope, and targeted performance goals (utilization, response time, query queue length, etc.) and server workload as well as other factors important to Baidu to determine the optimal power distribution policy. Baidu will set the policy and optimization strategy based on their work load and priority. Apply a common policy to the Using Intel Data Center Manager, set policy to each rack in terms of particular power budget target servers in a rack that the server has to observe Node-level monitoring Leveraging Node Manager features to adjust server power consumption to the target set by the and tracking against policy policy within 60 seconds and maintain at the target until further notice Node-level alert and notification Use Node Manager feature to detect and send alert when a server fail to reach policy target in 60 seconds or maintain the target during operation. Alert handling and mitigation Once an alert is received, the console needs to automatically decide upon a course of action to mitigate the risk ignore, set a new policy, or shutdown the troubled server, etc. Note: The last two use cases Node-level alert and notification and Alert handling and mitigation are not covered in this POC. 5
6 4. POC Architecture This POC was set up at Intel-Baidu joint lab on Baidu campus. The rig consisted of four Nehalem-EP based servers used in this POC with 2 Intel Quad-Core Xeon processors with eleven p-states (2.8 down to 1.6 GHz). Each server was configured with 18 GB of DDR3 memory and PSMI 1.44 instrumented power supplies. The servers are installed on a rack as a server group, managed by Intel Data Center Manager, as shown in Figure 2. The servers in the rack were loaded with the same operating system configuration, Red Hat* Linux Enterprise Version 4.0 Update 3 with customized kernel patches from Baidu. Each server was configured to run Baidu s workload stress test which measured the number concurrent queries a server could process every second. Each server under test also had Node Manager configured. Intel Data Center Manager was used to see server and rack level actual power consumption data. The Reference User Interface was used as the group management console. Data Center Manager monitored the actual power consumption on each server and aggregated total power consumption for the group (rack level.) Data Center Manager combines instances Node Manager across multiple servers to set appropriate policies thereby providing a mechanism to optimize power consumption for each node, yet stay within the constraint of a the rack-level power budget. For test purposes, we also connected watt meters to the rack and servers under test to monitor the rack level power consumption as an independent confirmation to the power numbers reported by the instrumented PSMI power supplies and the aggregated numbers provided by Data Center Manager. In most cases, there is a small discrepancy between watt meter and Node Manager figures. Baseline numbers were noted before running the actual tests. A load runner server was used to generate graduated loads for the servers in the rack. The tool also had a capability to generate execution statistics from the various workload tests carried out. Figure 2: POC Architecture Intel Data Center Manager Load Runner Server Policy Directives Notifications Analyze Power Sensors Performance & Utilization Sensors Monitor Autonomic Control Loop Act Controls for Subsystem Power Consumption (P-state) Intel Intelligent Power Node Manager 6
7 5. POC Results System architects wonder about the performance tradeoffs involved when voltage and frequency scaling are applied to a CPU running a workload. The figure below depicts parametric sensitivity curves of response times versus power capping. An initial set of calibration runs to establish asymptotic values for workloads in terms of number of threads (one query per thread) and response times at full power. The asymptotic query time is about 0.6 ms. At this point the system is considered fully loaded. Increasing the number of queries per second beyond this point starts degrading the response times appreciably. Additional plots were made with reduced number of threads to depict performance sensitivity to the number of threads. Plots were made at baseline, and 95, 90 and 85 percent of the number of original queries per second. Each curve represents the system response time as a function of power capping, from no capping at all to capping level set at 160 watts while the workload is held constant. Note a gentle degradation in response time until the power capping level reaches 230 watts. Baidu set the threshold for acceptable response time at 2 milliseconds. This threshold sets a practical limit for a power rollback of about 70 watts before the system crosses the threshold. Counter intuitively, for moderate power capping response time is slightly better for the lower thread counts plotted. This may indicate some thread processing overhead. The compression after the cap is set to 180 watts is due to the lower range of power control authority being reached. Figure 3: Effect of Power Capping on Search Response Time Optimal Capping Point 230W ms % 100% 90% 95% Acceptable Performance No Cap (300W) % 90% 100% 85% Cap State 7
8 6. Conclusion The 70 watt number is a precise actual number for power consumption derived from the instrumented power supplies in the Nehalem-based servers. This knowledge allows increasing the number of servers in a rack without exceeding the power limits imposed by the hosting provider. There are two approaches that we can apply to benefit from the results of this measurement. As indicated in Figure 4, the hosting provider imposes a 10A current limit per rack or about 10 A x 220 V = 2.2 KW ceiling per rack. The circuit breakers are actually built with 100 percent headroom. However, servers are provisioned to not exceed the nominal limit of 10 A, and will trip instantly if the current draw is doubled. Without the monitoring facilitated by the instrumented power supplies, the rack provisioning planners need to assume the more conservative figure of a derated nameplate figure, which amounts to 400 watts per server. Alternatively, for legacy platforms without power monitoring capability, this number is calculated through a pre-test measurement, adding extra power draw to account for the worst case from configuration changes during the server lifetime plus an additional safety margin. In this baseline case, if the best known figure is 400 watts, this means that a rack cannot be loaded beyond five servers without exceeding the power quota. For servers with the common 2U form factor a rack can usually take 20 servers. This means the rack must be left 75 percent empty with a significant waste of available rack space. Having the more precise power consumption figures from Node manager, the two strategies to improve the rack-level power utilization are the following: Safeguard strategy: This is a way to set up a safeguard limit for the maximum power consumption value for a given workload. In other words, we look at the historical record of actual power consumption readings provided by Node Manager and set a cap at the maximum power level to minimize power excursions beyond this set limit. This number is still significantly lower than the derated nameplate number. From the POC, we measured that a server typically consumes 300W or less. Hence if each server is operated with a Node Manager imposed ceiling of 300W, now we can load up the rack with seven servers for a total rack consumption of 300 watts x 7 = 2.1 KW, or 40 percent increase over the original, more conservative assumption of 400 watts per rack because we know that the servers won t consume more than 300 watts, and even if they do, the 300 watt policy limit will make excursions very unlikely. We assume that the hosting data center has sufficient thermal capacity to sustain the extra servers. Because the power limit has been set to the expected peak power usage, power capping will kick on only very rarely, and no performance impact is expected. Fine tuned strategy: This strategy requires several experiments of power capping at different levels yielding results similar to the ones described under the PoC results. The goal of these experiments is to determine the feasible capping range that still yields acceptable performance. These experiments take work but will deliver a finely tuned system that not only stays within the power envelope but also delivers acceptable performance according to preset criteria. This strategy requires active power capping at all times. For the experiments we performed, we learned that we could roll back power consumption down to 230W without undue deterioration in search response times. With power capped at 230 watts, we can now install eight servers in the rack for a total consumption of 1.9 KW (8x230W). If we set rack-level policy at 1,900W, we can now install three extra servers in the rack up from the original five. In other words, other things being equal, rack capacity had been increased by 60 percent. 8
9 Figure 4: Different Power Manager Strategies and Capacity Increases Rack Power Rack Power Budget 2,200W Server 5 Power ~400W est. Server 4 Power ~400W est. Server 3 Power ~400W est. Server 2 Power ~400W est. Server 1 Power ~400W est. Rack Capacity w/o NM Server 7 Power Server 6 Power Server 5 Power Server 4 Power Server 3 Power Server 2 Power Server 1 Power 40% More Rack Capacity Than Today Server 8 Power Server 7 Power Server 6 Power Server 5 Power Server 4 Power Server 3 Power Server 2 Power Server 1 Power 60% More Rack Capacity Than Today Rack Output Today No Node Manager Name Plan Estimate Safe Guard Strategy With Node Manager 300W Fine Tuned Strategy With Node Manager 230W Looking into the PoC results and subsequent analysis, it is clear that Intel Node Manager and Data Center Manager allow a significant increase in server density and compute capacity of a rack through dynamic power management policies. The rack consumption still stays within the present power envelope with acceptable performance impact. Node Manager Technology provides a monitoring capability and a defined power consumption ceiling allowing data center managers to safely increase rack loading between 40 and 60 percent. The power management approaches described in this document are relatively simple, derived from an initial study. The results reported in this study are by no means definitive. For workloads of different characteristics, additional, more aggressive power management approaches are possible that promise to increase the rack yield even further. 9
10 For more information on Intel Intelligent Power Node Manager and Intel Data Center Manager visit: datacentermanager.intel.com Copyright 2008 Intel Corporation. All rights reserved. Intel, the Intel logo, Core 2 Duo, Celeron, and vpro are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. This paper is for informational purposes only. THIS DOCUMENT IS PROVIDED AS IS WITH NO WARRANTIES WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR SAMPLE. Intel disclaims all liability, including liability for infringement of any proprietary rights, relating to use of information in this specification. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted herein. *Other names and brands may be claimed as the property of others.
Preserving Performance While Saving Power Using Intel Intelligent Power Node Manager and Intel Data Center Manager
WHITE PAPER Intel Intelligent Power Node Manager Intel Data Center Manager Data Center Power Management Preserving Performance While Saving Power Using Intel Intelligent Power Node Manager and Intel Data
The Efficient Data Center
WHITE PAPER Data Center Efficiency and Optimization Data Center Management The Efficient Data Center Using data center instrumentation and server refresh to optimize compute performance in constrained
IT@Intel. Memory Sizing for Server Virtualization. White Paper Intel Information Technology Computer Manufacturing Server Virtualization
White Paper Intel Information Technology Computer Manufacturing Server Virtualization Memory Sizing for Server Virtualization Intel IT has standardized on 16 gigabytes (GB) of memory for dual-socket virtualization
IT@Intel. Comparing Multi-Core Processors for Server Virtualization
White Paper Intel Information Technology Computer Manufacturing Server Virtualization Comparing Multi-Core Processors for Server Virtualization Intel IT tested servers based on select Intel multi-core
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent
Intel Data Center Manager. Data center IT agility and control
Intel Data Center Manager Data center IT agility and control The Data Center Ecosystem 2 Why do we care about Data Center Management? attributed to devices connected to the Internet of Everything (up from
Intel Data Direct I/O Technology (Intel DDIO): A Primer >
Intel Data Direct I/O Technology (Intel DDIO): A Primer > Technical Brief February 2012 Revision 1.0 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
Measuring Cache and Memory Latency and CPU to Memory Bandwidth
White Paper Joshua Ruggiero Computer Systems Engineer Intel Corporation Measuring Cache and Memory Latency and CPU to Memory Bandwidth For use with Intel Architecture December 2008 1 321074 Executive Summary
Red Hat Network Satellite Management and automation of your Red Hat Enterprise Linux environment
Red Hat Network Satellite Management and automation of your Red Hat Enterprise Linux environment WHAT IS IT? Red Hat Network (RHN) Satellite server is an easy-to-use, advanced systems management platform
Red Hat Satellite Management and automation of your Red Hat Enterprise Linux environment
Red Hat Satellite Management and automation of your Red Hat Enterprise Linux environment WHAT IS IT? Red Hat Satellite server is an easy-to-use, advanced systems management platform for your Linux infrastructure.
New Dimensions in Configurable Computing at runtime simultaneously allows Big Data and fine Grain HPC
New Dimensions in Configurable Computing at runtime simultaneously allows Big Data and fine Grain HPC Alan Gara Intel Fellow Exascale Chief Architect Legal Disclaimer Today s presentations contain forward-looking
Accelerating Business Intelligence with Large-Scale System Memory
Accelerating Business Intelligence with Large-Scale System Memory A Proof of Concept by Intel, Samsung, and SAP Executive Summary Real-time business intelligence (BI) plays a vital role in driving competitiveness
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel
Intel Service Assurance Administrator. Product Overview
Intel Service Assurance Administrator Product Overview Running Enterprise Workloads in the Cloud Enterprise IT wants to Start a private cloud initiative to service internal enterprise customers Find an
Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms
IT@Intel White Paper Intel IT IT Best Practices: Data Center Solutions Server Virtualization August 2010 Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms Executive
Benchmarking the OpenCloud SIP Application Server on Intel -Based Modular Communications Platforms
Technology White Paper Benchmarking the OpenCloud SIP Application Server on Intel -Based Modular Communications Platforms Executive Summary Application servers are vital to the success of IP Multimedia
Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms
EXECUTIVE SUMMARY Intel Cloud Builder Guide Intel Xeon Processor-based Servers Red Hat* Cloud Foundations Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms Red Hat* Cloud Foundations
Managing Capacity Using VMware vcenter CapacityIQ TECHNICAL WHITE PAPER
Managing Capacity Using VMware vcenter CapacityIQ TECHNICAL WHITE PAPER Table of Contents Capacity Management Overview.... 3 CapacityIQ Information Collection.... 3 CapacityIQ Performance Metrics.... 4
Linux on POWER for Green Data Center
Linux on POWER for Green Data Center Vaidyanathan Srinivasan IBM India Systems and Technology Labs Agenda POWER platform energy management features Linux OS energy management
Power and Cooling Innovations in Dell PowerEdge Servers
Power and Cooling Innovations in Dell PowerEdge Servers This technical white paper describes the Dell Energy Smart Architecture and the new and enhanced features designed into Dell PowerEdge 12 th generation
Power efficiency and power management in HP ProLiant servers
Power efficiency and power management in HP ProLiant servers Technology brief Introduction... 2 Built-in power efficiencies in ProLiant servers... 2 Optimizing internal cooling and fan power with Sea of
Using Intel Intelligent Power Node Manager to Minimize the Infrastructure Impact of the EMC* Atmos* Cloud Storage Appliances
White Paper by EMC Corporation and Intel Corporation Using Intel Intelligent Power Node Manager to Minimize the Infrastructure Impact of the EMC* Atmos* Cloud Storage Appliances An EMC/Intel Proof of Concept
Evaluating Intel Virtualization Technology FlexMigration with Multi-generation Intel Multi-core and Intel Dual-core Xeon Processors.
Evaluating Intel Virtualization Technology FlexMigration with Multi-generation Intel Multi-core and Intel Dual-core Xeon Processors. Executive Summary: In today s data centers, live migration is a required
COLO: COarse-grain LOck-stepping Virtual Machine for Non-stop Service
COLO: COarse-grain LOck-stepping Virtual Machine for Non-stop Service Eddie Dong, Yunhong Jiang 1 Legal Disclaimer INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
Dynamic Power Variations in Data Centers and Network Rooms
Dynamic Power Variations in Data Centers and Network Rooms By Jim Spitaels White Paper #43 Revision 2 Executive Summary The power requirement required by data centers and network rooms varies on a minute
Accelerating Business Intelligence with Large-Scale System Memory
Accelerating Business Intelligence with Large-Scale System Memory A Proof of Concept by Intel, Samsung, and SAP Executive Summary Real-time business intelligence (BI) plays a vital role in driving competitiveness
How High Temperature Data Centers and Intel Technologies Decrease Operating Costs
Intel Intelligent Management How High Temperature Data Centers and Intel Technologies Decrease Operating Costs and cooling savings through the use of Intel s Platforms and Intelligent Management features
Increasing Data Center Efficiency through Metering and Monitoring Power Usage
White Paper Intel Information Technology Computer Manufacturing Data Center Efficiency Increasing Data Center Efficiency through Metering and Monitoring Power Usage To increase data center energy efficiency
High Availability Server Clustering Solutions
White Paper High vailability Server Clustering Solutions Extending the benefits of technology into the server arena Intel in Communications Contents Executive Summary 3 Extending Protection to Storage
Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms
Intel Cloud Builders Guide Intel Xeon Processor-based Servers RES Virtual Desktop Extender Intel Cloud Builders Guide to Cloud Design and Deployment on Intel Platforms Client Aware Cloud with RES Virtual
Dell Reference Configuration for Hortonworks Data Platform
Dell Reference Configuration for Hortonworks Data Platform A Quick Reference Configuration Guide Armando Acosta Hadoop Product Manager Dell Revolutionary Cloud and Big Data Group Kris Applegate Solution
Implementing Cloud Storage Metrics to Improve IT Efficiency and Capacity Management
IT@Intel White Paper Intel IT IT Best Practices Cloud Computing and IT Efficiency July 2011 Implementing Cloud Storage Metrics to Improve IT Efficiency and Management Executive Overview Over the past year,
Host Power Management in VMware vsphere 5
in VMware vsphere 5 Performance Study TECHNICAL WHITE PAPER Table of Contents Introduction.... 3 Power Management BIOS Settings.... 3 Host Power Management in ESXi 5.... 4 HPM Power Policy Options in ESXi
Redbooks Paper. Local versus Remote Database Access: A Performance Test. Victor Chao Leticia Cruz Nin Lei
Redbooks Paper Victor Chao Leticia Cruz Nin Lei Local versus Remote Database Access: A Performance Test When tuning a database for better performance, one area to examine is the proximity of the database
Intel architecture. Platform Basics. White Paper Todd Langley Systems Engineer/ Architect Intel Corporation. September 2010
White Paper Todd Langley Systems Engineer/ Architect Intel Corporation Intel architecture Platform Basics September 2010 324377 Executive Summary Creating an Intel architecture design encompasses some
Dynamic Power Variations in Data Centers and Network Rooms
Dynamic Power Variations in Data Centers and Network Rooms White Paper 43 Revision 3 by James Spitaels > Executive summary The power requirement required by data centers and network rooms varies on a minute
Accelerating High-Speed Networking with Intel I/O Acceleration Technology
White Paper Intel I/O Acceleration Technology Accelerating High-Speed Networking with Intel I/O Acceleration Technology The emergence of multi-gigabit Ethernet allows data centers to adapt to the increasing
RAID Basics Training Guide
RAID Basics Training Guide Discover a Higher Level of Performance RAID matters. Rely on Intel RAID. Table of Contents 1. What is RAID? 2. RAID Levels RAID 0 RAID 1 RAID 5 RAID 6 RAID 10 RAID 0+1 RAID 1E
Proactive Performance Management for Enterprise Databases
Proactive Performance Management for Enterprise Databases Abstract DBAs today need to do more than react to performance issues; they must be proactive in their database management activities. Proactive
StruxureWare TM Center Expert. Data
StruxureWare TM Center Expert Data End to end data center infrastructure management software for monitoring and control of power, cooling, security and energy usage from the building through IT systems
Multi-core and Linux* Kernel
Multi-core and Linux* Kernel Suresh Siddha Intel Open Source Technology Center Abstract Semiconductor technological advances in the recent years have led to the inclusion of multiple CPU execution cores
SUN ORACLE EXADATA STORAGE SERVER
SUN ORACLE EXADATA STORAGE SERVER KEY FEATURES AND BENEFITS FEATURES 12 x 3.5 inch SAS or SATA disks 384 GB of Exadata Smart Flash Cache 2 Intel 2.53 Ghz quad-core processors 24 GB memory Dual InfiniBand
Summary. Key results at a glance:
An evaluation of blade server power efficiency for the, Dell PowerEdge M600, and IBM BladeCenter HS21 using the SPECjbb2005 Benchmark The HP Difference The ProLiant BL260c G5 is a new class of server blade
Server Technology, Inc.
Server Technology, Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2009-April-07 Headquarters Server Technology, Inc. 1040 Sandhill
VirtualCenter Database Performance for Microsoft SQL Server 2005 VirtualCenter 2.5
Performance Study VirtualCenter Database Performance for Microsoft SQL Server 2005 VirtualCenter 2.5 VMware VirtualCenter uses a database to store metadata on the state of a VMware Infrastructure environment.
White Paper. ACPI Based Platform Communication Channel (PCC) Mechanism. InSarathy Jayakumar Intel Corporation
White Paper ACPI Based Platform Communication Channel (PCC) Mechanism InSarathy Jayakumar Intel Corporation October 2015 Executive Summary This paper presents a detailed explanation of the APCI defined
Intel Media SDK Library Distribution and Dispatching Process
Intel Media SDK Library Distribution and Dispatching Process Overview Dispatching Procedure Software Libraries Platform-Specific Libraries Legal Information Overview This document describes the Intel Media
Taking Virtualization
Taking Virtualization to the SMB Market How Lenovo is driving Virtualization solutions for the SMB market by lowering costs and simplifying deployment White Paper Lenovo Virtualization Solutions Introduction
Three Paths to Faster Simulations Using ANSYS Mechanical 16.0 and Intel Architecture
White Paper Intel Xeon processor E5 v3 family Intel Xeon Phi coprocessor family Digital Design and Engineering Three Paths to Faster Simulations Using ANSYS Mechanical 16.0 and Intel Architecture Executive
Managing Orion Performance
Managing Orion Performance Orion Component Overview... 1 Managing Orion Component Performance... 3 SQL Performance - Measuring and Monitoring a Production Server... 3 Determining SQL Server Performance
Measuring Processor Power
White Paper Intel Xeon Processor Processor Architecture Analysis Measuring Processor Power TDP vs. ACP Specifications for the power a microprocessor can consume and dissipate can be complicated and may
Accelerating Data Compression with Intel Multi-Core Processors
Case Study Predictive Enterprise Intel Xeon processors Intel Server Board Embedded technology Accelerating Data Compression with Intel Multi-Core Processors Data Domain incorporates Multi-Core Intel Xeon
Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820
Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 This white paper discusses the SQL server workload consolidation capabilities of Dell PowerEdge R820 using Virtualization.
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System with Internal Storage Focusing on IPMI Out of Band Management Recipe ID: 19SYAM190000000011-01 Contents Hardware Components...3
Datasheet Fujitsu Cloud Infrastructure Management Software V1
Datasheet Fujitsu Cloud Infrastructure Management Software V1 Efficient infrastructure utilization, private cloud creation support, and reduced administration. Cloud Foundation for Iaas Fujitsu supports
Upgrading a Telecom Billing System with Intel Xeon Processors
WHITE PAPER Xeon Processors Billing System Migration Upgrading a Telecom Billing System with Xeon Processors Migrating from a legacy RISC platform to a server platform powered by Xeon processors has helped
How System Settings Impact PCIe SSD Performance
How System Settings Impact PCIe SSD Performance Suzanne Ferreira R&D Engineer Micron Technology, Inc. July, 2012 As solid state drives (SSDs) continue to gain ground in the enterprise server and storage
ARM* to Intel Atom Microarchitecture - A Migration Study
White Paper Mark Oliver Senior Systems Engineer Intel Corporation ARM* to Intel Atom Microarchitecture - A Migration Study November 2011 326398-001 1 Introduction At Intel, our engineers do not perform
StruxureWare TM Data Center Expert
StruxureWare TM Data Center Expert Infrastructure management from rack to row to room to building Deploy in minutes, manage from anywhere, analyze instantly, integrate with other management systems. End
Monthly Specification Update
Monthly Specification Update Intel Server Board S1400FP Family August, 2013 Enterprise Platforms and Services Marketing Enterprise Platforms and Services Marketing Monthly Specification Update Revision
Oracle Database Scalability in VMware ESX VMware ESX 3.5
Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises
Agenda. Context. System Power Management Issues. Power Capping Overview. Power capping participants. Recommendations
Power Capping Linux Agenda Context System Power Management Issues Power Capping Overview Power capping participants Recommendations Introduction of Linux Power Capping Framework 2 Power Hungry World Worldwide,
Solution Recipe: Improve PC Security and Reliability with Intel Virtualization Technology
Solution Recipe: Improve PC Security and Reliability with Intel Virtualization Technology 30406_VT_Brochure.indd 1 6/20/06 4:01:14 PM Preface Intel has developed a series of unique Solution Recipes designed
Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell
Solve your IT energy crisis WITH AN ENERGY SMART SOLUTION FROM DELL overcome DATA center energy challenges IT managers share a common and pressing problem: how to reduce energy consumption and cost without
Intel Desktop Board DG31GL
Intel Desktop Board DG31GL Basic Certified Motherboard Logo Program (MLP) Report 4/1/2008 Purpose: This report describes the DG31GL Motherboard Logo Program testing run conducted by Intel Corporation.
Intel Server Board S3420GPRX Intel Server System SR1630GPRX Intel Server System SR1630HGPRX
Server WHQL Testing Services Enterprise Platforms and Services Division Intel Server Board S3420GPRX Intel Server System SR1630GPRX Intel Server System SR1630HGPRX Rev 1.0 Server Test Submission (STS)
Demonstrating Cisco UCS Manager, Power Assure and Intel Data Center Manager to Power Manage Cisco UCS Racks and Blades
White Paper by Cisco, Power Assure and Intel Corporation Demonstrating Cisco UCS Manager, Power Assure and Intel Data Center Manager to Power Manage Cisco UCS Racks and Blades A Cisco, Power Assure and
Maximize Performance and Scalability of RADIOSS* Structural Analysis Software on Intel Xeon Processor E7 v2 Family-Based Platforms
Maximize Performance and Scalability of RADIOSS* Structural Analysis Software on Family-Based Platforms Executive Summary Complex simulations of structural and systems performance, such as car crash simulations,
Case Study - I. Industry: Social Networking Website Technology : J2EE AJAX, Spring, MySQL, Weblogic, Windows Server 2008.
Case Study - I Industry: Social Networking Website Technology : J2EE AJAX, Spring, MySQL, Weblogic, Windows Server 2008 Challenges The scalability of the database servers to execute batch processes under
Database Instance Caging: A Simple Approach to Server Consolidation. An Oracle White Paper September 2009
An Oracle White Paper September 2009 Database Instance Caging: A Simple Approach to Server Consolidation Introduction... 1 Scenarios for Server Consolidation... 2 Scenario 1: Non-Critical Databases...
Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card
Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card Version 1.0 April 2011 DB15-000761-00 Revision History Version and Date Version 1.0, April 2011 Initial
Streaming and Virtual Hosted Desktop Study
White Paper Intel Information Technology Streaming, Virtual Hosted Desktop, Computing Models, Client Virtualization Streaming and Virtual Hosted Desktop Study Benchmarking Results As part of an ongoing
The Benefits of POWER7+ and PowerVM over Intel and an x86 Hypervisor
The Benefits of POWER7+ and PowerVM over Intel and an x86 Hypervisor Howard Anglin [email protected] IBM Competitive Project Office May 2013 Abstract...3 Virtualization and Why It Is Important...3 Resiliency
Sizing Server Platforms To Meet ERP Requirements
IT@Intel White Paper Intel Information Technology Enterprise Resource Planning March 1 Sizing Server Platforms To Meet ERP Requirements Executive Overview We developed a quantitative model to assist with
Intel Embedded Virtualization Manager
White Paper Kelvin Lum Fee Foon Kong Platform Application Engineer, ECG Penang Intel Corporation Kam Boon Hee (Thomas) Marketing Development Manager, ECG Penang Intel Corporation Intel Embedded Virtualization
Host Power Management in VMware vsphere 5.5
in VMware vsphere 5.5 Performance Study TECHNICAL WHITE PAPER Table of Contents Introduction...3 Power Management BIOS Settings...3 Host Power Management in ESXi 5.5... 5 Relationship between HPM and DPM...
Intel Extreme Memory Profile (Intel XMP) DDR3 Technology
Intel Extreme Memory Profile (Intel XMP) DDR3 Technology White Paper January 2009 Document Number: 319124-002 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS
Upgrading Intel AMT 5.0 drivers to Linux kernel v2.6.31
White Paper Zerene Sangma Platform Application Engineer Intel Corporation Upgrading Intel AMT 5.0 drivers to Linux kernel v2.6.31 For Intel Q45 and Intel GM45 based embedded platforms June 2010 323961
An Oracle White Paper July 2011. Oracle Primavera Contract Management, Business Intelligence Publisher Edition-Sizing Guide
Oracle Primavera Contract Management, Business Intelligence Publisher Edition-Sizing Guide An Oracle White Paper July 2011 1 Disclaimer The following is intended to outline our general product direction.
Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage
Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage Technical white paper Table of contents Executive summary... 2 Introduction... 2 Test methodology... 3
Mitigating Risks and Monitoring Activity for Database Security
The Essentials Series: Role of Database Activity Monitoring in Database Security Mitigating Risks and Monitoring Activity for Database Security sponsored by by Dan Sullivan Mi tigating Risks and Monitoring
Developing Higher Density Solutions with Dialogic Host Media Processing Software
Telecom Dialogic HMP Media Server Developing Higher Density Solutions with Dialogic Host Media Processing Software A Strategy for Load Balancing and Fault Handling Developing Higher Density Solutions with
Intel Simple Network Management Protocol (SNMP) Subagent v6.0
Intel Simple Network Management Protocol (SNMP) Subagent v6.0 User Guide March 2013 ii Intel SNMP Subagent User s Guide Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL
Scaling up to Production
1 Scaling up to Production Overview Productionize then Scale Building Production Systems Scaling Production Systems Use Case: Scaling a Production Galaxy Instance Infrastructure Advice 2 PRODUCTIONIZE
Enhanced Intel SpeedStep Technology for the Intel Pentium M Processor
Enhanced Intel SpeedStep Technology for the Intel Pentium M Processor White Paper March 2004 Order Number: 301170-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
Intel Server S3200SHL
Server WHQL Testing Services Enterprise Platforms and Services Division Intel Server S3200SHL Server Test Submission (STS) Report For the Microsoft Windows Logo Program (WLP) Rev 1.0 October 16, 2006 This
Power Benefits Using Intel Quick Sync Video H.264 Codec With Sorenson Squeeze
Power Benefits Using Intel Quick Sync Video H.264 Codec With Sorenson Squeeze Whitepaper December 2012 Anita Banerjee Contents Introduction... 3 Sorenson Squeeze... 4 Intel QSV H.264... 5 Power Performance...
Roadmap for Transforming Intel s Business with Advanced Analytics
IT Best Practices Business Intelligence and IT Business Transformation November 2011 Roadmap for Transforming Intel s Business with Advanced Analytics Executive Overview is working in close partnership
Measuring Power in your Data Center
RESEARCH UNDERWRITER WHITE PAPER LEAN, CLEAN & GREEN Raritan Measuring Power in your Data Center Herman Chan, Director, Power Solutions Business Unit, and Greg More, Senior Product Marketing Manager There