1 1st February 2011 Evaluation Guideline regarding the Product Certificate GASKEUR Basic Label CV (Central Heating): 2010 for Central Heating Appliances
2 Preface This Evaluation Guideline has been adopted by the Kiwa Board of Experts of Energy Performance Label, wherein all the relevant parties in the field of supply, installation and use are represented. These Boards of Experts also supervises the certification activities and where necessary require the Evaluation Guideline to be revised. All references to Board of Experts in this Evaluation Guideline pertain to the above mentioned Boards of Experts. This Evaluation Guideline will be used by Kiwa in conjunction with the Kiwa- Regulations for Product Certification. This regulation details the method employed by Kiwa for conducting the necessary investigations prior to issuing the product certificate and the method of external control. This Evaluation Guideline is drawn up for certification purposes within the framework of GASKEUR appliance labelling. This certification is voluntary and supplementary, which implies that the label is neither obligatory for admission nor permits admission in its own right. To be admitted each appliance is required by law to bear the CE Marking. GASKEUR labels are supplementary, i.e. they provide information on a certain aspect of the appliance not clearly indicated by the CE Marking. This Evaluation Guideline states the basic requirements to be met by a central heating appliance to be eligible for GASKEUR labelling. In addition to this Evaluation Guideline, there are also Evaluation Guidelines for hot water appliances and for air heaters. As supplements to the basic labels there are labels for specific appliance properties such as efficiency, comfort and emissions for which criteria exist or which will be developed. These specific labels may only be obtained if the requirements for the basic label have been met. In order to continue harmonisation with the European standards and regulations, this Evaluation Guideline uses heat inputs and efficiencies based on the net calorific value (Hi). In order to ensure complete harmonisation with national legislation, in as far as it (still) makes use of the gross value; conversion information has been included where necessary. NOTE: This is a translation from the Dutch. In case of ambiguity or differences in interpretation between this translation and the original Dutch text, the Dutch text prevails.
3 Kiwa Nederland B.V. is a company with an international and independent reputation for testing and certification of gas and water related products for manufacturers and suppliers. These products include gas appliances, sanitary ware, measurement and control devices and installation and distribution materials. Kiwa Nederland B.V. also tests and certifies the raw materials for plastic pipe products. Furthermore, Kiwa Nederland B.V. certifies various quality, safety and environmental management systems for a wide range of customers. Kiwa Nederland B.V. also provides independent expertise in the form of consultancy in the field of installation safety. Kiwa Nederland B.V. is based in Apeldoorn and Rijswijk in the Netherlands and is accredited by the Dutch Council for Accreditation (RvA). Kiwa Nederland B.V. is appointed by the Dutch government as Notified Body in the field of the European Directives (CE Marking). All test work is carried out in Kiwa Nederland B.V. s own laboratories, which are accredited to ISO/IEC Kiwa Nederland B.V. PO Box 137, 7300 AC Apeldoorn, The Netherlands Wilmersdorf 50, 7327 AC Apeldoorn The Netherlands Telephone: +31(0) Fax: +31(0) Website: [email protected] Kiwa N.V. All rights reserved. No part of this book may be reproduced, stored in a database or retrieval system, or published, in any form or in any way, electronically, mechanically, by print, photoprint, microfilm or any other means without prior written permission from the publisher. The use of this Evaluation Guideline by third parties, for any purpose whatsoever, is only allowed after a written agreement is made with Kiwa to this end. Validation This Evaluation Guideline has been adopted by the Boards of Experts on 1 st December This Evaluation Guideline has been declared binding by Kiwa Nederland BV on 1 st Februari Kiwa Nederland B.V st February 2011
4 Contents Preface 1 Contents 3 1 Introduction General Field of Application / Scope Acceptance of Test Reports Provided by the Supplier Certificate 6 2 Terms and Definitions General Definitions Technical Definitions 8 3 Procedure for Granting the Quality Declaration Pre Certification Tests Granting the Certificate 10 4 General and Constructional Requirements General Nuisance Appliance Category Appliance Classification Open-Flued Appliances Room-Sealed Appliances Appliance Construction General Material Selection Composition Maintenance Evacuation of Flue Gases and Supply of Combustion Air Open-Flued Appliances Room-Sealed Appliances Connection of the Gas Supply External Connections for Controls Protection Against the Risk of Freezing Temperature Classification 14 Kiwa Nederland B.V st February 2011
5 5 Operational Requirements General Efficiencies Open-Flued Appliances Room-Sealed Appliances Flue Loss from Increased Airflow and from Wind Conditions Electrical Power Consumption Heating Performance Combustion Product Evacuation for Open-Flued Appliances with Mechanical Extraction Temperature Classification Combustion Product Temperature Limiter Condensation Frost Protection 16 6 Test Methods General Gaseous Fuel Combustion Air Supply and Flue Gases Evacuation Settings for the Appliance Efficiencies Open-Flued Appliances Room-Sealed Appliances Determination of the Flue Loss at Increased Airflow and in Windy Conditions Determination of the Electrical Power Consumption Heating Performance Determination of the Counter Pressure on the Flue Stub Determination of Flue Gas Temperatures for Temperature Classification Determination of the Operating Temperature Determination of the Peak Temperature Determination of the Correct Operation of the Combustion Product Temperature Limiter (If Applicable) Condensation in the Appliance Frost Protection 20 7 Labelling Inscriptions Documentation Installation Instructions User Information 22 Kiwa Nederland B.V st February 2011
6 8 Requirements in Respect of the Quality System Manager of the Quality System Internal Quality Control/Quality Plan Procedures and Working Instructions 23 9 Summary of Tests and Inspections Inspection Matrix Procedures for the Surveillance Programme Inspection of the Quality Management System Agreements on the Implementation of Certification General Certification Staff Qualification Requirements Qualification Report Pre Certification Tests Decision for Granting the Certificate Lay out of Certificate Nature and Frequency of External Inspections Corrections, Additions and Interpretations of Requirements Titles of Standards Standards/Normative Documents: 30 I Model Certificate 31 II Model IQC-scheme or Framework IQC Scheme 33 III GASKEUR Labels 35 IV Conversion of the Efficiency from Net Value to Gross Value 36 V Requirements for the Acceptance of Test Reports, Where Testing was Carried Out at the Laboratory of the Supplier 37 VI Flue Gas Construction at Initial Type Testing and Product Inspection 40 Kiwa Nederland B.V st February 2011
7 1 Introduction 1.1 General This Evaluation Guideline includes all relevant requirements which are adhered to by the CI as the basis for the issue and maintenance of a product certificate for the GASKEUR Basic Label. This Evaluation Guideline replaces GASKEUR CV:2002 Criteria, dated July 2002 with the accompanying corrections, additions and interpretations. The certificates issued based on those criteria lose their validity 6 months after this Evaluation Guideline has been adopted by the Board of Experts. For the performance of its certification work, the CI is bound to the requirements as included in the clause 4.6 conditions and procedures for granting, maintaining, extending, suspending and withdrawing certification of EN Field of Application / Scope This Evaluation Guideline applies to gas fired central heating appliances using water as the heat transmission medium and with a heat input of up to 900 kw (Hi). These appliances may be constructed as a complete appliance in which the burner, heat exchanger and other components are supplied as an integrated whole, or as a combination of a boiler body and an add-on burner that is part of the supply. This Evaluation Guideline also applies to central heating appliances with an integrated hot tap water facility (combination boilers and specific combinations of a boiler with an indirectly fired boiler, if this is assessed along with the boiler). 1.3 Acceptance of Test Reports Provided by the Supplier The requirements for accepting test reports from which the tests have been performed in the laboratory of the manufacturer, can be found in the normative Annex Certificate The product certificate to be issued based on this Evaluation Guideline is designated as a GASKEUR certificate. A model of the certificate to be issued on the basis of this Evaluation Guideline has been included as an Annex. Kiwa Nederland B.V st February 2011
8 2 Terms and Definitions 2.1 General Definitions In this Evaluation Guideline, the following terms and definitions are applicable: Evaluation Guideline: The agreements made by the Board of Experts regarding the subject of Certification. Board of Experts: The Board of Experts, appointed by Kiwa Nederland B.V. regarding the certification system for EPK quality marks. TI: The testing institute which carries out the approval testing programme. CI: The certification institute which carries out the certification and grants the certificates. Supplier: The party who is responsible for ensuring that the products continuously meet the requirements upon which the certification was granted. IQC Scheme: a description of the quality inspections carried out by the supplier as part of his quality system. Product Requirements: requirements made specific by means of measures or figures, focusing on (identifiable) characteristics of products and containing a limiting value to be achieved, which limiting value can be calculated or measured in an unequivocal manner. Approval Programme: The investigation to determine whether all requirements put forth in the Evaluation Guideline have been met. Surveillance Programme: the investigation which will be carried out after the issue of the certificate to determine if the certified products continue to meet the requirements set in the Evaluation Guideline, whereby it is also indicated which frequency the Surveillance Programme will be carried out by Kiwa. Remark: In the Inspection Matrix there is a summary of which programme will be carried out by Kiwa in the initial type testing and in the maintenance stage, and with which frequency the Surveillance Programme will be carried out. Product Certificate: A document in which the CI declares that a product at the time of delivery is considered to fulfil the product specifications as specified in the certificate. Kiwa Nederland B.V st February 2011
9 2.2 Technical Definitions Heat input The amount of energy which is supplied per unit of time in the form of gas to the gas appliance based on the calorific net value 1 of the gas. Symbol: Q Unit: kilowatt (kw). Nominal heat input Heat input under reference conditions according to the manufacturer. For appliances with an input range this will be considered to be the minimum and the maximum setting. Symbol: Q n Unit: kilowatt (kw). Input range The range, defined by a minimum and a maximum value within which the heat input may be set by way of a pre-setting. Output The amount of energy which is transferred per unit of time by the appliance to the heat-transporting medium (central heating water). Symbol: P Unit: kilowatt (kw). Nominal output The output under nominal conditions according to the manufacturer. Symbol: P n Unit: kilowatt (kw). Efficiency Relationship between the output and the heat input expressed as a percentage. Symbol: η Full load efficiency Relationship between the output at full load and the heat input. Symbol: η n Part load efficiency Relationship between the output at part load and the heat input. Symbol: η d Toxicity index Relationship between the measured CO and CO 2 percentage times 100; in formula form (%CO / %CO 2) x 100. Set-up area An area which is not designated as a boiler room in which an appliance is set up (for example a kitchen, attic, cupboard, workshop, production area, sports hall etc.). Boiler room Area intended for the setting up of a boiler with a (joint) nominal heat input equal to or greater than 130 kw. Combustion product temperature limiter A protective device that switches off the appliance if the flue gases exceed the maximum permitted operating temperature (EN 677:1998 "device for limiting the flue gases temperature"). 1 Heat inputs and efficiencies can be based on the calorific net value (H i ) or the calorific gross value (H S) of the gas. All heat inputs given in this Evaluation Guideline are based on the net calorific value (H i) of the gas. Kiwa Nederland B.V st February 2011
10 CLV system (combination air supply and combustion product evacuation system) System which works with the natural airflow and which consists of a combination of a pipe or duct for the common supply of combustion air and a pipe or duct for the common evacuation of flue gases. This system is only intended for type C appliances fitted with a fan. Common flue gases evacuation system System which works with the natural airflow and which consists of a pipe or duct for the common evacuation of flue gases. This system is only intended for type C appliances fitted with a fan and with an individual air supply system. Technically Identical Series With technically identical series it is meant that the appliances within such a series shall be built from main components with the same construction principle (e.g. the construction of the heat exchanger(s), pump, fan, burner, etc.). Example: appliances with heat exchangers or burners with different construction principles will therefore not be considered as one series. Appliances with heat exchangers or burners with the same construction principles, but where the heat exchangers or burners have different capacities, are considered as belonging to one series. Kiwa Nederland B.V st February 2011
11 3 Procedure for Granting the Quality Declaration 3.1 Pre Certification Tests The pre certification-tests to be performed are based on the (product) requirements as included in this Evaluation Guideline including the test methods and contain, de pending on the nature of the product to be certified: (sample) testing to determine whether the products comply with the product and/or functional requirements, Production Process Assessment Assessment of the quality system and the IQC-scheme, Assessment on the presence and functioning of the remaining procedure 3.2 Granting the Certificate After finishing the pre-certification tests the results are presented to the person deciding on granting of certificate. This person evaluates the results and decides whether the certificate can be granted or additional data and/or tests are necessary. Examples of certificates are given in Annex I. If a combination of labels is mentioned on the certificate, as well as the requirements of the Evaluation Guideline GASKEUR Basic Label CV (Central Heating): 2010 for Central Heating Appliances, the requirements of the Evaluation Guideline concerned also need satisfying, such as: Evaluation Guideline GASKEUR HR (High Efficiency, Heating): 2010 for Central Heating Appliances; Evaluation Guideline GASKEUR SV (Clean Combustion): 2010 for Central Heating Appliances; Evaluation Guideline GASKEUR CW-HRww (Comfort Hot Water-High Efficiency, Hot Water): 2010 for Central Heating Appliances, Instantaneous Water Heaters and Storage Water Heaters; Evaluation Guideline GASKEUR NZ (Reheating Solar boiler): 2010 for Central Heating Appliances, Instantaneous Water Heaters and Storage Water Heaters; Evaluation Guideline GASKEUR HRe (High Efficiency electricity): 2010 for Central Heating Appliances; Kiwa Nederland B.V st February 2011
12 4 General and Constructional Requirements 4.1 General The appliance should have a valid CE mark under the European Directive for Gas Appliances of 16 December 2009 (2009/142/EC). This marking should be based on at least a type inspection on the basis of the "Essential Requirements" as specified in Annex I to the above-mentioned Directive and the European standards and the associated supplements which are applicable to the appliance. 4.2 Nuisance The appliance must function without producing a nuisance level of noise in any operational phase. Any limited amount of gas that is released upon start up or upon extinguishing may not cause any nuisance (e.g. a gas smell). No condensation may be formed which is a nuisance during operation, or which pollutes the appliance or its environment. 4.3 Appliance Category Appliances should be in categories I2L, I3P, I3B, I3B/P, II2L3P, II2L3B or II2L3B/P. Appliances which are set up for natural gas should be suitable for a nominal inlet pressure of 2.5 or 10 kpa (= 25 or 100 mbar). Appliances which are set up for liquid gas should be suitable for a nominal inlet pressure of 3 or 5 kpa (= 30 or 50 mbar). 4.4 Appliance Classification Open-Flued Appliances Central heating appliances of type A are not eligible for the GASKEUR label. Open-flued central heating appliances with a natural flue gases evacuation duct (type B11) which can be placed in a set-up area should be type B11bs, which means that they should be fitted with an exhaust protection device ("ttb"). This flue gases evacuation protection device should comply with the requirements of EN This obligation does not apply to appliances which may only be located in boiler rooms. Open-flued central heating appliances with mechanical evacuation should be type B22 or B23. Appliances of types B12(bs), B13(bs), B21, B31, B32 and B33 are not eligible for the GASKEUR label. Type B14 is considered to be B11; all B4 type appliances are considered to be B1 appliances. 1 EN 297 applies up to a heat input of 70 kw, but under the GASKEUR label this requirement applies to all appliances that can be located in a set-up area. Kiwa Nederland B.V st February 2011
13 4.4.2 Room-Sealed Appliances Room-sealed appliances should be type C11, C12, C13, C31, C32, C33, C42, C43, C52, C53, C62, C63, C82 or C83 1. Appliances of types C21, C22, C23, C41, C51, C61, C71, C72, C73 and C81 are not eligible for the GASKEUR label. 4.5 Appliance Construction General The quality and the wall thickness of the materials from which the appliance is constructed, and also the way in which the various components are put together, should be such that the appliance will not undergo any major changes with respect to its constructional and operational characteristics during a reasonable life expectancy under normal circumstances with respect to installation and use. A reasonable life expectancy is considered to be a period of at least 10 years following installation and circumstances of use which are considered to be normal in the Netherlands Material Selection All appliance components should be able to withstand the mechanical, chemical and thermal conditions to which they will be exposed in normal use during the life expectancy of the appliance. Components of the appliance on which condensation can form such as during a cold start, low temperature operation, etc., should be made from corrosion-resistant material or from a material which is sufficiently protected against corrosion, unless the wall thickness is such that early failure may be considered to have been excluded Composition Connections at places where condensation may occur may not experience excessive corrosion. For this reason, seams and gaps should be avoided as much as possible. Appliances in which condensation can occur in the flue gases evacuation duct (on the basis of EN 297:1994/A5 "Criteria for Condensation in the Flue") should either be fitted with a condensation drain for the condensation which occurs in the flue gases evacuation system or it should be clearly stated in the installation instructions that this device should be fitted. In appliances that are not specifically intended for setting up in a boiler room, this facility should be constructed in accordance with NPR 3378 part 42. Appliances in which condensation can also occur in a balanced state, should comply with the applicable Evaluation Guideline for the GASKEUR HR label with respect to the evacuation of condensation and the construction and material choice for the parts in contact with condensation. 1 Appliances of types C42 and C43 are only admitted for use on a CLV system and appliances of types C82 and C83 are only admitted for use on a common exhaust system. 2 With respect to the distribution gas it may be assumed that the total sulphur content will not amount to more than 50 mg/m 3 Kiwa Nederland B.V st February 2011
14 4.5.4 Maintenance It must be possible to carry out periodic cleaning and maintenance work with tools which are normally available without having to disconnect the connections to the appliance, with the exception of the electrical connection (plug), the gas supply (appliance valve), combustion product evacuation duct and any condensation outlet. The combustion product side seal of the appliance should only be achieved through mechanical means. For components that have to be disassembled during normal maintenance no pastes or sealants may be used as a sealing agent unless it is not necessary to replace them during maintenance. The seal of the appliance should also be guaranteed after repeated cleaning and maintenance work. 4.6 Evacuation of Flue Gases and Supply of Combustion Air Open-Flued Appliances Open-flued central heating appliances that are supplied without a flue construction should be fitted with a flue connection with an internal diameter so that flue material with diameters in accordance with Table 1 can be directly applied. Use of an adapter is only permitted if this is part of the delivery of the appliance and is to be assessed as an integral component during inspection. For open-flued central heating appliances with mechanical extraction this flue connection should be at least suitable for the minimum pipe diameter which is required for a flue system resistance length of at least 6m and for opening out into the area for "free outflow", area I, of NPR 3378 part 61:1999, or in accordance with NEN 2757 the area where Δp out = 0 Pa applies. Generally obtainable flue diameters (mm) in the Netherlands Table Room-Sealed Appliances Room-sealed central heating appliances which are supplied without a flue gases evacuation construction should be fitted with a combustion air supply and combustion product flue connection with an internal diameter such that the supply and flue material with diameters in accordance with Table 1 can be directly connected. If a diameter modification or a crossover from concentric to parallel (or vice versa) is desired, then an adapter may be used which is also delivered if it is also to be tested as part of the appliance during the inspection of the appliance in the seal testing examination. The connections should be gas-tight after installation. For appliances which may be located in a set-up area this should be achieved without the use of extra devices. This means that the connecting stubs should be fitted with, for example, a suitable rubber lip ring. Kiwa Nederland B.V st February 2011
15 4.7 Connection of the Gas Supply The central heating appliance should be fitted with a good connection facility for the gas supply. This connection must be manufactured from materials which are generally available in the Netherlands for making detachable gas-tight connections, such as right-handed sealing pipe thread in accordance with ISO 7-1 (conical outside thread and cylindrical inside thread) or compression fittings in accordance with KE 35 or BRL K 623/01. For connection sizes larger than 1¼" use may also be made of a flanged joint in accordance with ISO 7005, as long as the counter flange and packing material is also supplied. A flange joint is mandatory for connection sizes greater than 2". 4.8 External Connections for Controls The appliance should be properly accessible and located in a circuit with a safe, very low voltage connection point for the connection of the wiring for the room thermostat and other external controls. 4.9 Protection Against the Risk of Freezing Appliances to which combustion air is supplied from the outside air should be fitted with a safeguard against the risk of freezing. Exceptions to this are appliances with a built-in fan in which the combustion air and the flue gases are supplied or removed respectively through a concentric duct and terminal system Temperature Classification If the manufacturer indicates that the appliance is suitable for connection to a plastic combustion product evacuation system, then the temperature class should be indicated in accordance with Table 2: Temperature class Operating temperature ( C) Peak temperature ( C) T T T T T T T T Table 2 Kiwa Nederland B.V st February 2011
16 5 Operational Requirements 5.1 General The operational requirements are based on the test conditions in article. 6.1 unless otherwise indicated. 5.2 Efficiencies The water-side (= direct) efficiencies for the heating function of the appliance must at least comply with the following values: for appliances with a heat input of not more than 100 kw: full load at least 88.5% part load at least 86.5% for appliances with a heat input greater than or equal to 100 kw but not more than 400 kw: full load at least 88% % points per 10 kw heat input part load at least 86% % points per 10 kw heat input for appliances with a heat input greater than or equal to 400 kw: full load at least 90 % part load at least 88 % These requirements apply for both the minimum and the maximum adjustable heat input for appliances with an input range within which the heat input can be adjusted in advance Open-Flued Appliances In open-flued appliances the efficiencies should be measured in accordance with article Room-Sealed Appliances In room-sealed appliances the efficiencies should be measured in accordance with article Flue Loss from Increased Airflow and from Wind Conditions For open-flued appliances the flue loss may not be more than 2% greater than the flue loss for a normal airflow at a static airflow which is 10 Pa higher than the normal airflow. For room-sealed appliances, in the event of wind gusts of 12 m/s, the flue loss may not rise by more than 5% compared to the flue loss with no wind Electrical Power Consumption From the electrical power consumption, with the exception of that of the circulation pump for the central heating function, for appliances with a nominal heat input up to and including 25 kw, a maximum of 50 W and, for appliances with a nominal heat input greater than 25 kw, a maximum of 2 W/kW heat input will be left out of consideration for the determination of efficiency. The remaining electrical power consumption will be deducted from the efficiency on the basis of primary energy (see Annex IV). Kiwa Nederland B.V st February 2011
17 5.3 Heating Performance Under the conditions in accordance with Article 6.3 and set up in accordance with the manufacturer s instructions, the appliance must be capable of: 1. providing a supply water temperature of 90 C at a return water temperature of 70 C, or 2. providing a supply water temperature of 90 C at a higher return temperature than 70 C if this is the result of adjustment by any heat input control (modulation on the basis of water temperature. There must then be an indication in the instructions at which supply water temperature this regulator acts. This may not, however, be before 80 C. There must also be an indication at which relative heat input the maximum temperature of 90 C will be reached), or 3. providing a supply water temperature of 80 C at a return water temperature of 60 C. In this case the instructions must expressly indicate that the appliance is designed for heating systems which are intended for a temperature regime of C as a maximum. 5.4 Combustion Product Evacuation for Open-Flued Appliances with Mechanical Extraction For open-flued appliances which are fitted with a fan for the transportation of the flue gases, the following data should be determined and supplied: a) the counter pressure on the flue stub whereby the appliance operates during a cold start; b) the counter pressure on the flue stub whereby the appliance just remains in operation; c) a summary of the calculated possibilities for the flue gases evacuation system on the basis of the counter pressures in a) and b) determined in accordance with article 6.4, and in relation to the outflow area in accordance with NPR At the counter pressures occurring in a) and b) the toxicity index may not exceed the value 2 during testing in accordance with article Temperature Classification The temperature class of the appliance must correspond to the class in which according to Table 2 both the operating temperature and the peak temperature fall. If the operating temperature and the peak temperature fall in different classes then the higher of the two applies as the temperature class of the appliance. 5.6 Combustion Product Temperature Limiter If the appliance is fitted with a combustion product temperature limiter then it may not activate under normal circumstances, including during a cold start. 5.7 Condensation Under the applicable conditions according to EN 297/A5:1998 no condensation may occur in the appliance or the flue gases evacuation system unless the component in question is designed and constructed as such in accordance with article Frost Protection If in accordance with article 4.9 a protective device against the risk of freezing is required then this should engage the appliance when the temperature of the outgoing boiler water is less than 5 C. Kiwa Nederland B.V st February 2011
18 6 Test Methods 6.1 General Gaseous Fuel The measurements, unless otherwise specified, are taken with the reference gas or gasses at the nominal supply pressure for the appliance category in question as stated in EN 437, EN 438 and EN 677 and on the basis of the following conditions: - Ambient temperature: 20 C ± 2 C (hourly average with setpoint 20 C) - Humidity: 70 % ± 5% - Barometric pressure: kpa - Wobbe and calorific value: net value (H i) - Air velocity: < 0.5 m/s Combustion Air Supply and Flue Gases Evacuation The diameter of the flue gases evacuation duct and of any air supply pipe should be in accordance with the installation instructions or should correspond to the diameter of the connection stub of the appliance. Open-flued appliances with a natural airflow are fitted with a vertical flue gases evacuation duct with a length of 1m. In open-flued appliances which are fitted with a fan for the transportation of the combustion air or gasses the tests are carried out at the lowest value of the counter pressure on the flue stub at which the appliance can become operational. Room-sealed appliances should be fitted with an air supply duct and a flue gases evacuation duct of the shortest length specified in the manufacturer's specification. The inlet and outlet shall lie in zones of equal pressure Settings for the Appliance An appliance that has heat input modification by way of a pre-setting should be set at the highest nominal heat input. An appliance that has a facility for the preparation of hot tap water (combination appliance) should be assessed with the tap water preparation function switched on. If there is also a heat retention switch then this must be set at the highest position. If this is not done for particular reasons then this will be recorded in the inspection dossier for verification of the basic assumptions for the testing for the underlying GASKEUR labels. Where it is not otherwise stated in this Evaluation Guideline the other settings will be in accordance with the manufacturer s specifications and recorded in the inspection dossier. 6.2 Efficiencies Open-Flued Appliances Both the water-side full load efficiency and the part load efficiency will be determined in accordance with the direct method as in EN 297:1994/A2:1996/A2- C1:2006, art and art Kiwa Nederland B.V st February 2011
19 6.2.2 Room-Sealed Appliances Both the water-side full load efficiency and the part load efficiency will be determined in accordance with the direct method as in EN 483:1999/A2:2001/AC:2006, art and art Determination of the Flue Loss at Increased Airflow and in Windy Conditions Open-flued appliances are made operational at nominal heat input as in article 6.1. When temperature balance has been reached, the flue loss is determined at normal airflow. The measurement is then repeated with an increased static airflow at the flue gases evacuation duct, which is 10 Pa higher than the normal airflow in the first measurement. Room-sealed appliances are made operational at nominal heat input as in article 7.1, without wind gusts on the supply and evacuation terminal of the appliance. When temperature balance has been reached, the flue loss is determined. The measurement is then repeated at a horizontal wind of 12 m/s in direction of the axis of the terminal. If the capacity of the fan is dependent on the load on the appliance then the measurement should also be carried out at the lowest capacity of the fan and the associated highest and lowest heat input values of the appliance, as far as applicable Determination of the Electrical Power Consumption The electrical power consumed by the appliance is determined in such a manner that the power consumed by the circulation pump is measured separately and specified in the inspection dossier. For the assessment of compliance with the requirement in articl the electrical consumption of the pump is not, however, taken into consideration. 6.3 Heating Performance The appliance is made operational at nominal heat input as in article 6.1, while the water circulation is continued with the built-in circulation pump or set in accordance with the installation instructions with the aid of an external pump. When a return water temperature of 60 C has been achieved the supply water is checked to see if it is at a temperature of 80 C. If it is not expressly stated that the appliance is only suitable for installations which are laid out for C then the testing will be continued by regulating the cooling load in such a manner that the return water temperature only rises by a maximum of 2 K/minute until the supply water temperature reaches 90 C. During this measurement a check will be made on whether and, if so, at which supply temperature the appliance begins to modulate back and at which heat input the supply temperature reaches 90 C. Compliance with the requirements of article 5.3 are subsequently checked. 6.4 Determination of the Counter Pressure on the Flue Stub The appliance is fitted with a flue gases evacuation duct with a nominal diameter corresponding to that of the flue stub of the appliance and with a length of 10 times this diameter. The pressure measurement point is located in the pipe at a height of 5 times the diameter. a) The appliance is calibrated on the reference gas at the nominal heat input or at the maximum heat input if the appliance has an input range. The values in question are determined as follows: for the determination of the maximum duty pressure the appliance is started cold with a fully closed flue gases evacuation duct. The terminal is then gradually opened until the appliance Kiwa Nederland B.V st February 2011
20 commences operation. The counter pressure in the flue gases evacuation duct is then measured at that moment. b) For the determination of the shutdown pressure the supply water temperature is set to 80 C. Once temperature balance has been reached the terminal from the flue gases evacuation duct is gradually closed. The pressure in the flue gases evacuation duct is measured at the moment when the combustion air safety device cuts in. For the counter pressures in a) and b) the toxicity index is determined under the following conditions: In a state of heating up where the water temperature is approx. 20 C and after a delay of about 10 seconds beginning from the moment the burner is ignited In a balance state where the boiler water has an ingoing temperature of 40 C and an outgoing temperature of 60 C In a balance state where the boiler water has an ingoing temperature of 60 C and an outgoing temperature of 80 C. 6.5 Determination of Flue Gas Temperatures for Temperature Classification Determination of the Operating Temperature The control thermostat of the appliance is set to its highest position. The flue gases evacuation duct is fitted at a maximum height of 0.5m from the flue stub with a spider-shaped measurement probe including a temperature sensor to determine the temperature of the flue gases. The appliance is made operational as specified in 7.1 at a heat input that is 5% higher than the nominal heat input respectively the highest heat input in the input range. The volume flow of the water is set at a temperature increase for the water (difference between supply and return) of 20 K and the heat emission is set at a temperature increase for the supply water of a maximum of 2 K/min. The pressure in the evacuation duct is regulated in such a manner that the highest flue gases temperature occurs. The highest flue gases temperature is then determined before, during and after the moment when the control thermostat engages. This is the operating temperature Determination of the Peak Temperature The control thermostat of the appliance is bridged. If the thermostat maximum can be adjusted then it is set to the highest position and then the appliance is put into operation and calibrated in the same way as in article The highest temperature is then determined before, during and after the moment of locking out. This is the peak temperature. 6.6 Determination of the Correct Operation of the Combustion Product Temperature Limiter (If Applicable) The appliance is put into operation and adjusted in the same way as in article The control thermostat is then set to the highest value. The appliance is then operated at around the switching point of the control thermostat until no rise in temperature has been observed for some time. Then check for compliance with the first requirement of article 5.6. Kiwa Nederland B.V st February 2011
21 6.7 Condensation in the Appliance The appliance is subjected to a test in accordance with EN297/A5:1998 article 4.11 under the associated conditions. A check is made for compliance with article Frost Protection For the assessment of the switching value prescribed in Article 5.8 a separate test of the protection device is sufficient. Kiwa Nederland B.V st February 2011
22 7 Labelling 7.1 Inscriptions If the appliance is certified on the basis of the GASKEUR Regulations and also meets the requirements set out in this Evaluation Guideline, the manufacturer may obtain the right to apply the GASKEUR Basic label. The label shall be as indicated in Annex 3. If a combination of labels are mentioned on the certificate, as well as the requirements of the Evaluation Guideline GASKEUR Basic Label CV (Central Heating): 2010 for Central Heating Appliances, the requirements of the Evaluation Guideline concerned also need satisfying, such as: Evaluation Guideline GASKEUR HR (High Efficiency, Heating): 2010 for Central Heating Appliances; Evaluation Guideline GASKEUR SV (Clean Combustion): 2010 for Central Heating Appliances; Evaluation Guideline GASKEUR CW-HRww (Comfort Hot Water-High Efficiency, Hot Water): 2010 for Central Heating Appliances, Hot Water Appliances and Hot Water Storage Appliances; Evaluation Guideline GASKEUR NZ (Reheating Solar boiler): 2010 for Central Heating Appliances, Hot Water Appliances and Hot Water Storage Appliances; Evaluation Guideline GASKEUR HRe (High Efficiency electricity): 2010 for Central Heating Appliances; 7.2 Documentation The appliance should be accompanied by a documentation package with instructions for the installer and for the user Installation Instructions In addition to that which is stated in the European Directive on Gas Appliances the installation instructions should also contain: (if applicable) The instruction that the appliance is designed for installations which are laid out for a supply temperature of 80 C and a return temperature of 60 C, and that it is therefore not suitable for installations which work on a regime. The counter pressure value on the flue stub at which the appliance operates during a cold start (see article 5.4) The counter pressure value on the flue stub at which the appliance just remains in operation (see article 5.4) The electrical power consumption during full load, part load and stand-by An instruction and a summary of the possibilities for constructing a combustion gas evacuation system based on the data specified above (if applicable) An instruction for the correct installation and connection of the combustion product temperature limiter (if applicable) The temperature classification Kiwa Nederland B.V st February 2011
23 7.2.2 User Information In addition to that which is stated in the European Directive on Gas Appliances the user instructions should also contain: (if applicable) an explanation of the operation of the frost protection (if applicable) an explanation of the operation of the combustion gas temperature limiter Kiwa Nederland B.V st February 2011
24 8 Requirements in Respect of the Quality System This chapter contains the requirements which have to be met by the supplier s quality system. 8.1 Manager of the Quality System Within the supplier s organizational structure an employee must have been appointed who is in charge of managing the supplier s quality system. 8.2 Internal Quality Control/Quality Plan The supplier shall have an internal quality control scheme (IQC scheme) which is applied by him. The following must have been demonstrably recorded in this IQC scheme: what aspects are checked by the producer; according to what methods such inspections are carried out; how often these inspections are carried out; in what way the inspection results are recorded and kept. This IQC scheme should at least be an equivalent derivative of the model IQC scheme included in the addendum. 8.3 Procedures and Working Instructions The supplier shall be able to submit the following: procedures for: dealing with products showing deviations; corrective actions to be taken if non-conformities are found; dealing with complaints about products and/or services delivered; the working instructions and inspection forms used. Kiwa Nederland B.V st February 2011
25 9 Summary of Tests and Inspections In this chapter a summary is given of the following items, which form part of the certification process: Approval Programme; Inspection of general, constructive and functional requirements; Procedure for the surveillance programme; Inspection of the quality management system; Furthermore, it is also indicated with which frequency the Surveillance Programme will be carried out by the CI. 9.1 Inspection Matrix Description of Requirements Article in Investigation in relation to: Guideline Approval Programme Surveillance by Kiwa after issue of the certificate Inspection Frequency General and Constructional Requirements Basic requirements 4.1 x x 1 x per 24 mths Nuisance 4.2 x x 1 x per 24 mths Appliance category 4.3 x x 1 x per 24 mths Appliance classification 4.4 x x 1 x per 24 mths Appliance construction 4.5 x 1 x per 24 mths Evacuation of Combustion Gases and 4.6 x 1 x per 24 mths Supply of Combustion Air Connection of the gas supply 4.7 x 1 x per 24 mths External connections for controls 4.8 x 1 x per 24 mths Protection against the risk of freezing 4.9 x 1 x per 24 mths Temperature classification 4.10 x 1 x per 24 mths Operational Requirements General 5.1 x x 1 x per 24 mths Efficiencies 5.2 x x 1 x per 24 mths Heating performance 5.3 x x 1 x per 24 mths Evacuation of flue gases for open flued 5.4 x 1 x per 24 mths appliances with mechanical extraction Temperature classification 5.5 x 1 x per 24 mths Combustion gas temperature limiter 5.6 x 1 x per 24 mths Condensation 5.7 x 1 x per 24 mths Frost protection 5.8 x 1 x per 24 mths 1) With significant changes of the product or production process, compliance with the (product) requirements shall be reconfirmed. 2) The given inspections shall be carried out by Kiwa at their premises 3) Procedures for the surveillance programme are given in 9.2 4) The inspections given for the surveillance programme shall be carried out on one appliance per technically identical series. Kiwa Nederland B.V st February 2011
26 9.2 Procedures for the Surveillance Programme Description for the procedure of settings input during the surveillance programme. The appliance for the surveillance programme will be selected by Kiwa from the running production line or stock of the manufacturer or importer. The selected appliance is removed from its box by the TI at their premises and is connected and adjusted in the test environment conforming to the included installation manual. Subsequently, it will be determined whether the appliance is functioning correctly and to what extent the corrected heat input (Q c, conform to Article of the EN 483:1999) and/or the actual heat input (Q i, conform to Article of the EN 483:1999) deviates from the nominal heat input as indicated on the identification plate of the appliance (Q n, conform to EN 483:1999). The following three situations can occur: Situation 1: (Q c < 0,95Q n) or (Q c > 1,05Q n) In case the appliance has been set and the corrected heat input deviates by more than 5% from the nominal heat input according to the identification plate, then the measurements will be stopped. This is designated as a failure. Situation 2: (Q c 0,95Q n and Q i 0,98Q n) or (Q i 1,02Q n and Q c 1,05Q n) In the case that the appliance has been set and the actual heat input deviates by more than 2% and the corrected heat input deviates by more than 5% from the nominal heat input according to the identification plate, then: 1. The TI will discuss with the manufacturer whether the measurements regarding the surveillance programme can be started, or whether the appliance needs to be adjusted to fall within the 2% heat input deviation from the nominal heat input according to the identification plate. 1.1 In the case that the manufacturer indicates that the measurements regarding the surveillance programme can be started, these measurements will be begun; 1.2 In the case that the manufacturer indicates that the appliance needs to be adjusted to fall within the 2% heat input deviation from the nominal heat input according to the identification plate, the TI will assess whether the adjustments needed are marginal. Marginal means here that the adjustments are within the limits of the usual production tolerances which can occur In the case that the adjustments, as assessed by the TI are marginal, then the manufacturer or the TI, on assignment and after written permission of the manufacturer has been received, will apply these adjustments 1 and the actual heat input will be re-measured In the case that the actual heat input deviates by less than 2% from the nominal heat input as indicated on the identification plate, then the measurements in regards to the surveillance programme will be started. 1 For example, if relevant set points have not yet been incorporated in the GASKEUR test report, this still needs to be carried out. Kiwa Nederland B.V st February 2011
27 Situation 3: (0,98Q n < Q i < 1,02Q n) In the case that the actual heat input deviates more than 2% from the nominal heat input as indicated on the identification plate, then, after discussion with the manufacturer, step 1.2 may be repeated or this will be designated as a failure. In the case that the actual heat input deviates by less than 2% of the nominal heat input as indicated on the identification plate, then the measurements in regards to the surveillance programme will be started. 9.3 Inspection of the Quality Management System The quality management system of the supplier will be inspected by the CI once per year. This assessment will comprise at least the aspects as indicated in the Kiwa Regulations for Product Certification. Kiwa Nederland B.V st February 2011
28 10 Agreements on the Implementation of Certification 10.1 General Beside the requirements included in this Evaluation Guideline, also the general rules for certification as included in the Kiwa Regulations for Product Certification apply. These rules are in particular The general rules for conducting the pre-certification tests, to be distinguished in: 1. the way suppliers are to be informed about an application is being handled, 2. how the test are conducted, 3. the decision to be taken as a result of the pre certification tests. The general directions for conducting inspections and the aspects to be audited, The measurements to be taken by Kiwa in case of Non Conformities, Measurements taken by Kiwa in case of improper Use of Certificates, Certification Marks, Pictograms and Logos, Terms for termination of the certificate, The possibility to lodge an appeal against decisions of measurements taken by Kiwa Certification Staff The staff involved in the certification may be sub-divided into: certification experts: they are in charge of carrying out the pre-certification tests and assessing the inspectors reports; inspectors: they are in charge of carrying out external inspections at the supplier s works; decision-makers: they are in charge of taking decisions in connection with the pre-certification tests carried out, continuing the certification in connection with the inspections carried out and taking decisions on the need to take corrective actions Qualification Requirements The qualification requirements comprise the following: The qualification requirements for the operational certification personnel of a CI which comply to the requirements set down in EN 45011; The qualification requirements for the operational personnel of a CI which have additionally been set down by the Board of Experts regarding the subject of this Evaluation Guideline. Kiwa Nederland B.V st February 2011
29 Education and experience of the certification personnel involved shall be demonstrably registered. Certification Expert Inspector Decision-Maker Education General Education- Specific Experience General Experience Specific Relevant technical higher professional education Internal training in certification and Kiwa policy Training in audit skills Evaluation Guideline orientated training Specific courses and training (knowledge and skills) 1 year relevant work experience with a minimum of 4 approval programmes of which 1full programme independently, under supervision Knowledge of Evaluation Guideline on detailed level and 4 approval programmes concerning the specific Evaluation Guideline or related Evaluation Guideline senior secondary vocational education Internal training in certification and Kiwa policy Training in audit skills Evaluation Guideline orientated training Specific courses and training (knowledge and skills) 1 year relevant work experience with a minimum of 4 approval programmes of which 1 independently, under supervision Knowledge of Evaluation Guideline on detailed level and 4 approval programmes concerning the specific Evaluation Guideline or related Evaluation Guideline Higher professional education Internal training in certification and Kiwa policy Training in audit skills Not applicable, unless specific requirements have been set by the Board of Experts 4 years work experience, of which at least 1 related to certification Knowledge of the basics of the specific Evaluation Guideline Qualification The qualification of the Certification staff shall be demonstrated by means of assessing the education and experience to the requirements mentioned before. In case staff is to be qualified on the basis of deflecting criteria, written records shall be kept. The authority to qualify staff is dedicated to: decision makers: qualification of certification experts and inspectors, Management of Kiwa: qualification of decision makers Report Pre Certification Tests The Certification Institute records the results of the pre certification tests in a report. This report shall comply with the following requirements: completeness: the reports verdicts about all requirements included in the Evaluation Guideline, traceability: the findings on which the verdicts have been based shall be recorded traceable, basis for decision: the decision maker shall be able to base his decision on the findings included in the report. Kiwa Nederland B.V st February 2011
30 10.4 Decision for Granting the Certificate The decision for granting the certificate shall be made by a qualified decision maker which has not been involved in the pre certification tests. The decision shall be recorded traceable Lay out of Certificate The product certificate shall be conform the model included as an annex Nature and Frequency of External Inspections The certification body shall carry out Audits at the supplier at regular intervals to check whether the supplier complies with his obligations. About the frequency of inspections the Board of Experts decides. At the time this Evaluation Guideline took effect, the frequency of the number of inspection visits per year is set according to Chapter 9. Inspections shall at least refer to: The suppliers IQC-scheme and the results obtained from inspections carried out by the supplier, The correct way of marking of certified products Complying with required procedures The results of each inspection shall be traceable recorded in a report Corrections, Additions and Interpretations of Requirements Corrections and additions will be drawn up by the TC GASKEUR and may or may not be approved by the Board of Experts. The TC GASKEUR may record the interpretation of requirements of this Evaluation Guideline in one separate interpretation document. Kiwa Nederland B.V st February 2011
31 11 Titles of Standards 11.1 Standards/Normative Documents: NEN-EN 297 NEN-EN 298 NEN-EN 303 NEN-EN 437 NEN-EN 483 NEN-EN 625 NEN-EN 656 NEN-EN 676 NEN-EN 677 NEN EN NEN 1078:2004 NEN 2078 NEN 2757 NEN 3028 NPR 3378 NEN 5128:2004/ A1:2009 (EPN) Gas-fired central heating boilers - Type B boilers fitted with atmospheric burners of nominal heat input not exceeding 70 kw Automatic gas burner control systems for gas burners and gas burning appliances with or without fans Heating boilers with forced airflow burners. Test gases - Test pressures - Appliance categories Gas-fired central heating boilers - Type C boilers of nominal heat input not exceeding 70 kw Gas-fired central heating boilers - Specific requirements for the domestic hot water operation of combination boilers of nominal heat input not exceeding 70 kw Gas-fired central heating boilers - Type B boilers of nominal heat input exceeding 70 kw but not exceeding 300 kw Automatic forced airflow burners for gaseous fuels Gas-fired central heating boilers - Specific requirements for condensing boilers with a nominal heat input not exceeding 70 kw Chimneys - System chimneys with plastic flue liners - Requirements and test methods Gas installations with an operational pressure of up to and including 500 mbar performance requirements new build Requirements for industrial gas installations Supply of combustion air and extraction of flue gases from combustion appliances in buildings Methods of determination Requirements for combustion Installations Practical guidelines gas installations Energy performance of houses and accommodation method of determination. NEN is considering publishing a new version of the NEN 5128, named NEN As soon as the standard comes into force, this document will be updated and this will be communicated. Kiwa Nederland B.V st February 2011
32 I Model Certificate Model Certificate - GASKEUR Basic / HR / SV Kiwa Nederland B.V st February 2011
33 Model Certificate - GASKEUR EPN Kiwa Nederland B.V st February 2011
34 II Model IQC-scheme or Framework IQC Scheme On the following page a template of an IQC scheme is given which is referred to in Chapter 8. Kiwa Nederland B.V st February 2011
35 Inspection Items Inspections Aspects Inspection Method Supplied Materials: Material Certificates Inspection Frequency Inspection Registration Components: Production Process Production apparatus, equipment: Procedures, Work instructions, used apparatus End Products Declarations of conformity and/or CE certificates Entry Inspection of applied components Brand and Type Specifications Registration of procedures and equipment used. Inspection methods Inspection frequency Registration and documentation of inspection results and equipment used. Procedures, Work instructions, used apparatus Means for measuring and testing Inspection methods Inspection frequency Registration and documentation of inspection results and equipment used. Branding Non-compliance boundaries List and status of used measuring and testing equipment and testing Calibration and maintenance reports Logistics Internal transport Storage Packaging Branding Delivery Documents Drawings Instructions Labelling Procedure in the case of non-compliance Procedure and documentation Complaints procedure Procedure, registration and closure Kiwa Nederland B.V st February 2011
36 III GASKEUR Labels In this annex a selection of possible GASKEUR-labels are shown. These labels can be applied to the appliance after approval by the CI for the GASKEUR labels concerned. GASKEUR Basic label GASKEUR Basic + HR label. In this example the HR 104 label is shown, this can also be the HR100 or HR107 label. GASKEUR Basic + SV label GASKEUR Basic + CW label. In this example the CW class 3 label is shown. This can be class 1 to 6. GASKEUR Basic + HRe label. (Here the e stands for the electric component in micro-chp (combined heat and power) appliances). A possible combination of GASKEUR labels is shown above. These are: GASKEUR Basic + HR107 + SV + CW5 + HRww + NZ label. Kiwa Nederland B.V st February 2011
37 IV Conversion of the Efficiency from Net Value to Gross Value The efficiency values according to the criteria relate to the net calorific value (H I) of the energy supplied. For situations where the gross calorific value (H S) is still used for communications, as is the case in NEN 5128 (EPN), the values should be converted. To do this the conversion factors (relationship between gross and net calorific value) for each form of energy supplied are used in accordance with the most recent version of NEN In the NEN 5128 the following values are given (Table C.6): natural gas (G25): Hi / Hs = propane (G31): Hi / Hs = butane (G30): Hi / Hs = electricity: Hi / Hs = In order to convert the efficiency to the gross value the value of η determined in this Evaluation Guideline is multiplied by the ratio between the net calorific value and the gross value of the energy form(s) in question. The result is therefore smaller (efficiency seems to be lower). For an accurate conversion this should be done in relation to the supplied form of energy (pay attention to the proportion of electricity). N.B.: The η determined in this way corresponds to the η which is used in NEN 5128 (EPN) for entering appliance efficiency. Power Station Efficiency For the efficiency of the electricity generation in the power station use should be made of the value in the most recent NEN 5128, taking into account the determination of the gross and net values. In the NEN 512 the following values are given for this (art. 15.2): η el = 0.39 (at gross value) η el;ow = 0.39 / = (at net value) Kiwa Nederland B.V st February 2011
38 V Requirements for the Acceptance of Test Reports, Where Testing was Carried Out at the Laboratory of the Supplier Approval Programme Possibilities for Acceptance Regarding the Approval Programme, there are two possibilities for acceptance of test reports, where testing was carried out at the laboratory of the supplier. 1. Laboratory Agreement with the Supplier; If the supplier can produce a so-called Laboratory Agreement which has been undersigned by a CI, then the CI can accept the test results of the supplier according to the procedure documented in this Laboratory Agreement. 2. Witnessing at the Supplier s Premises; Measurement results of the supplier can be accepted by witnessing the measurements carried out by the supplier. The following aspects need to be taken into consideration regarding the selection of the (size of) the spot check of the measurements carried out by the supplier: Are there any measurement results which are close to the limit for noncompliance? Measurements in the area of the non-compliance limits must always be checked. As a rule of thumb, all these results must be within 5% of the non-compliance limit (this does not apply to all properties; common sense should also be used). Are there any measurement results which can be used for commercial ends (such as a HR label)? Commercially relevant measurement results shall always be checked. Are there any properties known regarding the test object concerned which are more critical than average (e.g. cold start using limit gas)? Properties which are known to be more critical than average shall always be checked. Are there significant differences between the results of the manufacturer and its own measurement results? When there are more significant differences then further measurements need to be checked. In general, around 10% of the measurements must be examined. If there are significant differences, this percentage needs to be doubled (in extreme cases, until 100% have been examined). Furthermore, there are a number of fixed rules which apply to witness measurements in all cases, namely: The location where the measurements are carried out shall be clearly indicated in the report. Kiwa Nederland B.V st February 2011
39 Calibration certificated from acceptable traceable calibrations (carried out by accredited calibration institutes) must be incorporated into the report, or must be traceable by the CI. Regarding the use inaccuracy, the measuring equipment used must comply with the same requirements which are applied to the measuring equipment of Kiwa. The make, model and serial number of every instrument used must be incorporated into the report. Verified measurement values shall be initialled on the measurement sheets by the acting certification expert. In both cases at least once a year a comparison will be made between the measurements taken by Kiwa of an appliance which has already been tested by the supplier, and the results from the supplier s test of the same appliance. The results of Kiwa have precedence. Correction Procedure The maximum allowable deviation between the measurement results of the supplier and Kiwa are given in Table 1 below: Measured Value/ Parameter abs / rel value Tolerance HR Efficiency (CV nominal) absolute value -1% ; +1% Compared to Kiwa HR Efficiency (CV 30%) absolute value -1,5%; +1,5% Compared to Kiwa Efficiency (Tap water) absolute value -2.5%; +2.5% Compared to Kiwa Flow relative value -10%; +10% Compared to Kiwa Heat Input relative value -2%; +2% Compared to Kiwa Temperature absolute value -1 C; +1 C Compared to Kiwa Waiting Time absolute value -2 s; +2 s Compared to Kiwa Emission CO2 absolute value -0.3 %; +0.3% Compared to Kiwa Emission CO / Nox absolute value -10 ppm; +10ppm Compared to Kiwa Pressure Resistance tap water circuit absolute value bar; bar Compared to Kiwa Table 1 The correction procedure, which is applied from the moment of comparison up to the moment of the first following comparison, has two distinct possibilities: 1. The efficiency measurement installation of the supplier is identical to the efficiency measurement installation of Kiwa (same software and components). If the measurement values of the supplier are at or within the tolerance limits as indicated in Table 1, then no correction is needed. If the measurement values of the supplier are outside the tolerance limits as indicated in Table 1, then a correction takes place of the measurement value of the supplier based on the deviation compared to the applicable tolerance. Table 2 shows examples of how corrections of efficiencies should be dealt with in the case of identical efficiency measurement installations. Kiwa Nederland B.V st February 2011
40 HR Efficiency (CV 30%) Tolerance -1.5%; +1.5% Measured Value Difference Correction Declared Kiwa Supplier Value by the Supplier Table 2 2. The efficiency measurement installation of the supplier is not identical to the efficiency measurement installation of Kiwa (same software and components). The measurement values of the supplier are corrected with the difference in measurement values between Kiwa and the supplier. Table 3 shows examples of how to deal with efficiencies in the case of differing efficiency measurement installations. Efficiencies (%) Efficiency Appliance 1 Kiwa Efficiency Appliance 1 Supplier Difference % Efficiency Appliance 2 Supplier Efficiency Appliance 2 Value declared by supplier Table 3 Surveillance Programme The surveillance programme takes place at Kiwa. 1 1 The testing set ups of Kiwa have already been used for approval and surveillance programmes for a long period of time. To ensure that no large differences occur in the measurement results, the efficiency measurement installations of Kiwa are considered to be the reference point. Kiwa Nederland B.V st February 2011
41 VI Flue Gas Construction at Initial Type Testing and Product Inspection Introduction An analysis has been carried out by Kiwa into how deviations of efficiency values could have arisen between the initial type testing and the product inspection. The following conclusion has been made: Initial type testing has been carried out using a parallel flue gas system, whilst the product inspection was carried out using a concentric flue gas system, or vice versa. This can lead to deviations. In the past the actual manner of assessing was insufficiently recorded. Currently, all variables which can have an influence on the assessment results and which are apparent to Kiwa are recorded on measurement sheets. This enables Kiwa to perform the initial type testing and the product inspection under identical conditions. However, it has not been determined which concentric flue gas pipe needs to be used for the initial type testing as well as the product inspection. This is explained in this annex. Basic Assumptions: The appliance cannot be supplied under appliance category C6 The choice of the supplier is between an assessment using a parallel or a concentric configuration (it must of course be possible for the appliance to be brought to market in the configuration chosen). Thereafter, all later assessments must be carried out using the configuration originally selected, for both the initial type testing as well as product inspections. For the initial type testing and the product inspection, the supplier delivers the flue gas configuration according to the choice made, whereby the assessment is made using the shortest possible configuration, at least consisting of a terminal (wall or roof) and the components necessary to connect the appliance. The flue gas system chosen and used during the initial type testing will be recorded in the report (photograph, drawings etc.). The appliance can be supplied under appliance category 6 The choice of the supplier is between measurement using a parallel or a concentric configuration. Thereafter, all later measurements must be carried out using the configuration originally selected, for both the initial type testing as well as product inspections. The selected configuration for the flue gas system as described below and used during the initial type testing, will be recorded in the report (photograph, drawings etc.). This means that the assessments are carried out using standard components as described below, for a parallel or concentric flue gas system, based on the selection of the supplier. Kiwa Nederland B.V st February 2011
42 Standard Configuration of the Flue gas System for Appliances with a Heat Input up to 70 kw: For a parallel flue gas system the following configuration shall be used: Vertical flue pipe with a length of 50 cm and a diameter of 80mm; Air inlet with a 90 bend with a diameter of 80mm; The flue pipe material is aluminium. For a concentric flue gas system, the following configuration shall be used: Concentric 90 bend, 80/125mm; Horizontal concentric terminal 80/125mm, complete with an aluminium lining pipe and with a length 775mm; If the appliance is supplied with a concentric flue gas system with different values than 80/125mm, then an adaptor (reducer) to 80/125mm needs to be utilised. Evaluation Guideline Kiwa Nederland B.V. GASKEUR Basic Label CV: st February 2011
43 Concentric Wall Terminal 80/125mm Kiwa Nederland B.V st February 2011
44 Concentric 90º bend 80/125mm Kiwa Nederland B.V st February 2011
45 Concentric Adapter 60/100 mm to 80/125mm Kiwa Nederland B.V st February 2011
46 Standard Configuration of the Flue Gas System for Appliances with a Heat Input from 70 kw to 120kW: For a parallel flue gas system the following configuration shall be used: Vertical flue pipe with a length of 50 cm and a diameter of 100mm; Air inlet with a 90 bend with a diameter of 100mm; The flue pipe material is aluminium. For a concentric flue gas system, the following configuration shall be used: Concentric roof terminal, 100/150mm, complete with an aluminium lining pipe and with a length of 1745mm; If the appliance is supplied with a concentric flue gas system with different values than 100/150mm, then an adaptor (reducer) to 100/150mm needs to be utilised. In the case that the above flue gas systems cannot be applied, the supplier shall deliver the flue gas systems according to the installation instructions, whereby the assessment will take place using the shortest possible configuration. The flue gas system chosen and used during the initial type testing will be recorded in the report (photograph, drawings etc.). Concentric Roof Terminal 100/150mm Kiwa Nederland B.V st February 2011
47 Appliances with a Heat Input Exceeding 120 kw: The choice of the supplier is between an assessment using a parallel or a concentric configuration (it must of course be possible for the appliance to be brought to market in the configuration chosen). Thereafter, all later assessments must be carried out using the configuration originally selected, for both the initial type testing as well as product inspections. For the initial type testing and the product inspection, the supplier delivers the flue gas configuration according to the choice made, whereby the assessment is made using the shortest possible configuration, at least consisting of a terminal (wall or roof) and the components necessary to connect the appliance. The flue gas system chosen and used during the initial type testing will be recorded in the report (photograph, drawings etc.). Installation of Flue gas System: Concentric: The outlet of the concentric wall terminal needs to be placed facing the same direction as the airflow in the testing area, in order to avoid the build up of resistance in the flue gas system and the associated influence on the heat input. Parallel: The 90º bend for the air inlet shall be placed facing the same direction as the airflow in the testing area. Kiwa Nederland B.V st February 2011
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most
COUNCIL DIRECTIVE 92/42/EEC of 21 May 1992 on efficiency requirements for new hot-water boilers fired with liquid or gaseous fuels
1992L0042 EN 11.08.2005 003.001 1 This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents B COUNCIL DIRECTIVE 92/42/EEC of 21 May 1992 on
Session 2: Hot Water Supply
MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
High-efficient gas boiler CompactGas
High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard
NATIONAL ASSESSMENT GUIDELINE FOR THE KOMO PROCESS CERTIFICATE FOR THE INSTALLATION OF FACADE CLADDING USING ADHESIVE SYSTEMS
BRL 4104 01-02-2003 NATIONAL ASSESSMENT GUIDELINE FOR THE KOMO PROCESS CERTIFICATE FOR THE INSTALLATION OF FACADE CLADDING USING ADHESIVE SYSTEMS Accepted by the Harmonisatie Commissie Bouw of the Stichting
EcoDesign & Labelling Directive (ErP)
EcoDesign & Labelling Directive (ErP) Jeff House November 2015 Baxi Make it Easy 1 What is ErP? ErP is a European Wide Directive designed to: Improve efficiency of heating & hot water products Generate
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Continuous flow direct water heating for potable hot water
Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial
User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
GAS HEATING IN COMMERCIAL PREMISES
ENERGY EFFICIENCY OFFICES GAS HEATING IN COMMERCIAL PREMISES www.energia.ie www.energia.ie Typically, energy reductions of 10% or more can be made easily through maintenance and low cost improvements.
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
E-gas Instant Gas Water Heaters
The Proven Preferred Choice! E-gas Instant Gas Water Heaters Training & Information Manual: There are important functional and operational differences between the conventional hot water geyser and the
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move
Heating with wood chips and pellets
YOUR RELIABLE PARTNER Heating with wood chips and pellets Present on the market 110 for over years 90-150 Advantages of the HERZ firematic boiler User friendly with: Easy operation Automatic cleaning system
When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You
Heating Options Furnaces & Boilers September 2005 CONSUMERS GUIDE - TO HOME HEATING OPTIONS CONTENTS Heat Distribution Energy Source Boilers Proper Sizing Energy Efficiency - Standards - Rating System
SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS
SASO XXXX:2016 (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS PERFORMANCE REQUIREMENTS AND METHODS OF TESTING 1 LARGE CAPACITY AIR CONDITIONERS
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2013 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Heat
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
Fossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
Energy Saving Fact Sheet Boilers
Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,
Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump
Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump The basics... This guide can help you make an informed
BER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
INTEC Engineering GmbH Heating Solutions for the Marine Industry
INTEC Engineering GmbH Heating Solutions for the Marine Industry Thermal Oil Heaters Heating Solutions for the Marine Industry Compared to conventional plants using hot water or steam, thermal oil as a
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................
BRL-K23001/04. Evaluation Guideline for aerosol fire extinguishing for the product certificate for fixed dry aerosol fire extinguishing components
2010-07-01 Evaluation Guideline for aerosol fire extinguishing for the product certificate for fixed dry aerosol fire extinguishing components Preface This evaluation guideline has been accepted by the
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines
Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines Content Introduction...5 Standard ambient matched engine...5 Operating at high seawater with standard matched engine...6 Non-standard
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
SASO 2663 :2014 ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS
SASO 2663 :2014 (SASO 2663/2012 including the modifications approved in Saudi Council Board No../2014) ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS ENERGY LABELLING
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Technical aspects of ErP for boilers and water heaters, Ecopliant Workshop for MSAs
Helsinki, 2014-05-20 Technical aspects of ErP for boilers and water heaters, main risks for noncompliance Ecopliant Workshop for MSAs Karl-Heinz Backhaus Agenda 1 Vaillant Group 2 Verification General
Hot Water Heating: Technologies and Use
Hot Water Heating: Technologies and Use Skip Hayden Integrated Energy Systems CanmetENERGY Better Buildings by Design 2010 Burlington Vermont February 2010 Natural Resources Canada Ressources naturelles
WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS
WORKING DOCUMENT ON Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS WORKING DOCUMENT in the framework of the implementation of
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
New OIML Document Surveillance of utility meters in service based on sampling inspections
COMMITTEE DRAFT OIML CD3 Date: 13 July 2010 Reference number: CD3 Supersedes document: CD2 (2006.02.16) OIML TC 3/SC 4 Circulated to P- and O-members and liaison international bodies and external organisations
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Operating instructions
Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document
Zehnder Focus 200. Ventilation device
Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Instructions for designing heating systems.
Instructions for designing heating systems. In order to obtain the required effect, a lower consumption, a smaller quantity of impurities and improved comfort, heat and domestic hot water installations
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
Decree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
Daikin Altherma. hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet
INSTALLATION REQUIREMENTS FOR DOMESTIC GAS WATER HEATERS ( RATED HEAT INPUT UP TO 70 kw )
THE GOVERNMENT OF THE HONG KONG SPECIAL ADMINISTRATIVE REGION INSTALLATION REQUIREMENTS FOR DOMESTIC GAS WATER HEATERS ( RATED HEAT INPUT UP TO 70 kw ) CODE OF PRACTICE GU 03 Issue 2 : October 2001 (Rev.
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES
1. Introduction TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES 1.1 This scheme details the tests and inspection of diesel engines manufactured by mass production system for use in marine
European Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE)
COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE) August 2007 Issue 2 Table of Contents 1. Foreword and Scope...1 2. Terminology...3 3. General...5 4. Gas Meter...6 5. Pipe Connection
Flamco. Flexcon M. Installation and operating instructions. 2002 Flamco 18501067
Flexcon M E Installation and operating instructions 2002 Flamco 1801067 Flamco b.v. P.O. Box 11 2800 AC Gouda - Holland Industriestraat 6 2802 AC Gouda - Holland Tel.: +31(0)182 91800 Fax: +31(0)182 227
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
Vaillant s plain English guide to. simple, concise and precise
Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005
KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO SAUDI STANDARD DRAFT No. 3457/2005 NON-DUCTED AIR CONDITIONERS AND HEAT PUMPS TESTING AND RATING PERFORMANCE This standard is developed
CHAPTER 9: WATER HEATING
Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage
IMQ RULES. Contents. IMQ Rules - Product certification
IMQ RULES PRODUCT CERTIFICATION "ELECTRIC ENERGY METERS AND METER UNITS" PRODUCT OF NEW MANUFACTURING Contents IMQ Rules - Product certification Particular Rules for the Electric energy meters and meter
Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.
Gas water heaters Why Vaillant? Because warm water is our business for more than 5 years. atmomag turbomag Innovative Ideas for warm water Vaillant Gas Water Heaters atmomag and turbomag Since the beginning
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems
Date(s) of Evaluation: CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems Assessor(s) & Observer(s): Organization: Area/Field
Commercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
Raad voor Accreditatie (Dutch Accreditation Council RvA) Assessment of Conformity Assessment Schemes
Raad voor Accreditatie (Dutch Accreditation Council RvA) Assessment of Conformity Assessment Schemes Document code: RvA-T033-UK Version 3, 28 februari 2014 A Rv A-Explanatory note describes the policy
Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH
Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges
DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
29.3.2014 Official Journal of the European Union L 96/149 DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling Sadrºaj 1 Technical data 2 1.1 Boiler properties TEMY PLUS P 25............................. 3 1.2 On Product............................................
MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
BFC. High Efficient Condensing Water Heater BFC - 28/30/50/60/80/100/120. Installation, User and Service Manual. Innovation has a name.
BFC High Efficient Condensing Water Heater BFC - 28/30/50/60/80/100/120 5015 - Changes Reserved. 0311704 Installation, User and Service Manual Innovation has a name. your installer A.O. Smith UK, Unit
Performance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS
January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About
Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation
Qualification Guide BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation BPEC 600/5270/3 - Level 2 NVQ Diploma in Plumbing and Heating BPEC
Vitocaldens 222-F Compact Gas-Hybrid appliance
Vitocaldens 222-F Compact Gas-Hybrid appliance Heating systems Industrial systems Refrigeration systems 2/3 Vitocaldens 222-F: The future-proof energy-source mix in one appliance Choosing Vitocaldens