SNS-101 IP Streamer DVB-S FTA/MultiCrypt to IP
|
|
|
- Adela Adams
- 10 years ago
- Views:
Transcription
1 IP Streamer DVB-S FTA/MultiCrypt to IP Multicast streamer for IP broadband networks. Up to eight simultaneous DVB-S satellite television programs for Free-To-Air (FTA) or MultiCrypt encoded for streaming over IP multicast networks. Designed and manufactured by Messrs Ikusi of Spain. Sold and supported by Teletechnique Beechmont in Queensland. 14 Jacaranda Court, BEECHMONT QLD 4211, Australia Phone: +61-(0) Fax: +61-(0) [email protected] Web: - ABN
2 CFP-500 Ref POWER +24V 60mA 5A Power (Television on IP Networks) «SNS» DVB-S/S2 to IP Streaming Equipment CE DVB-S/S2 IP Streamers Model SNS-100 SNS-102 slot Operator's Smart Card SNS-100 SNS-102 /02 Conax, Cryptoworks, Irdeto KeyFly, Mediaguard, Nagravision Viaccess, etc. Reference Reception Maximum number of de-encrypted services SNMP Support traps DiSEqC equipped (vers. 1.08) Frequency range Input Section Input level (QPSK/8PSK)) Input loop-through gain Input symbol rate Standard Bit rate Output Section Transmission protocols (IP) No. of simultaneous streams Multicast RF input (loop-through) DC connection Connectors entrance Configuration Ethernet output Supply voltage Consumption Max DiSEqC current General Indicator leds Operating temperature Dimensions MHz dbm db MS/s Mbps VDC ma ma C mm 5100 DVB-S FTA Each module is packed with: - 1 F plug bridge, 64 mm length, for input tap line. - 1 DC plug bridge, 53 mm length, for connection of +12 VDC voltage. No No DVB-S DVB-S/S2 FTA or MultiCrypt (Common Interface - EN 50221) Variable ( depending) Yes Yes (±1) IEEE /100 BaseT up to 100 UDP / RTP up to 8 Yes (2x) female F "banana" socket slot RS 232 / DB-9 RJ included: 480 (DVB-S),, 790 (DVB-S2) 300 ON - - LINK - ACT x 195 x 32 QPSK MS-0908 QPSK SNS Headends An SNS headend for DVB-S/S2 to IP streaming includes: - As many SNS streamers as there are DVB-S/S2 transponders whose programmes one want to broadcast on the IP network. The or SNS-102 must be utilized when the transponder transmits one or more encrypted programmes that one want to de-encrypt; a (Conditional Acces Module) containing an Operator's Smart Card must fit the front panel slot. modules are not supplied by IKUSI. - One or more CFP Power Supplies. - One or more Rack-frames or Baseplates. The baseplates can be joined horizontally. - Usually, one housing unit. The SNS streamers have two directionally coupled input ports that facilitate simple connection of the incoming Sat-IF signal using the plug bridges supplied. Besides this, the headends with or SNS-102 models are able to use Sat-IF multiswitches, what allows to change at any time the Sat-IF signal fed into each streamer without recabling the headend. Ethernet switch IP Network Example of SNS headend for eight digital satellite TV transponders. Contains 8 and 1 CFP-500 power supply, all fixed on 1 BAS-900 baseplate. This headend can feed the IP network with up to 64 TV programmes (8 programmes at the most per streamer).
3 Television on IP Networks () FTA or MultiCrypt DVB-S IP Streamer Common Interface Configuration and Settings User Manual
4 EN Configuration and Setting of the Streamer Module User Manual November 2008 Revision C IKUSI - Ángel Iglesias, S.A. Paseo Miramón, San Sebastián SPAIN Tel.: Fax:
5 CONTENTS Introduction... 4 This Manual... 4 Product Description... 4 Chapter One - Configuration of the Streamer... 5 Configuration Save/Restore Configuration General Report Chapter Two - Streamer Settings DiSEqC Configuration Input Settings Output Settings SAP Channel Settings User Menu SNMP Configuration... 23/24 Chapter Three - Streamer Status Information Status Information Chapter Four - Streamer Reports Input Services Output Streams System Logs
6 Introduction This Manual This manual describes the configuration and settings programme for the Streamer Module. It is the second part of the user documentation for said module, the first part of which is the Installation and Access manual supplied in paper format. Product Description streamers are DVB-S to IP gateways designed to broadcast in multicast on an IP network the services (TV or Radio programmes) issued from FTA or encrypted digital satellite reception; in case of encrypted signal, a containing the operator's smart card must fit the front panel slot. The IP streams can be viewed using an IPTV set-top box or a software video player. modules have an IKUSI ClassA mechanical format. As such, they are fixed to BAS-700 / BAS-900 baseplates or to an SMR-601 rack frame, and are +12 VDC powered from a CFP module. Characteristics Input: 1 DVB-S transport stream (MPTS). Output: up to 8 simultaneous, IP-encapsulated services (TV or Radio programmes), with individual multicast addresses. Information filtering of DVB tables. UDP & RTP transmission protocols. Web interface for configuration and setting. Alarm information SNMP agent. SAP & SDP protocols that facilitate automatic service selection on the user's STB and provide information to external servers. ADVANCED PID filtering PSI/SI parsing Transparent ECM & EMM messaging PAT and PMT table regeneration Routing or blocking for CAT, NIT, SDT, EIT, TDT tables Configurable QoS marking Configurable Time To Live When the connection is established between the streamer and the control PC, the programme access screen appears: Programme Access Screen Once the desired programme language has been chosen [ English (en), Spanish (es), French (fr) ], enter the password and click on OK. Note: The default password admin can (and must) be changed as explained on page 9. 4
7 Chapter One - Configuration of the Streamer In this Chapter Configuration Save/Restore General Report 5
8 Configuration General Configuration Initial program screen The first screen that appears when the programme is accessed contains the "Output" window, which gives information on the IP streams that have been created on the module and which may or may not be incorporated into the output data stream. On the left of this screen are the menus that access all of the programme's functionalities. Figure Initial programme screen Click on the General menu on the left of the screen to display a dropdown list containing the 3 options: Configuration, Save/Restore and General Report. Click on Configuration. The Configuration window will appear : Figure Identification card of the Configuration window. Identification The identification card (Figure 1.2) provides basic data on the streamer. The different card fields are completed as follows: 6
9 Configuration "Model":. This data cannot be changed. "Serial Number": Informational data which cannot be changed. "Firmware Version": As above. "Identifier": Any name that the installer or operator wishes to assign to the streamer module can be entered here. "Location": Enter the postcode of the installation site if required. "Installer": The installer's identification details can be entered here. "Contact": Then enter their contact details (telephone number, ). "Installation date": The date on which the streamer module was installed can be entered here. Click on the Save button at the bottom of the window to store the information on the streamer module, this information is then shown each time the module is accessed. 7
10 Configuration Network Click on the Network tab to configure the streamer's ethernet connection parameters. The following card is displayed: Figure Network card of the Configuration window. "Use DHCP to get IP address": If this box is checked, the module will use the DHCP protocol for assigning dynamic IP addresses. Consequently, no data needs to be entered in the next five fields on the tab. If the administrator of the network on which the SNS headend is installed assigns static IP addresses, the box will not be checked and the following fields will need to be filled in. WARNING: If this option is activated, the IP address assigned to the streamer can only be known by consulting the DHCP server management system. "IP Address": Enter the IP address that you wish to assign to the streamer. This address must fall within the range of local network addresses. "Network mask": Enter the local network mask. "Default gateway": Enter the IP address of this gateway. This information is only required if you want the streamer to access Internet. "Primary DNS server": Enter the primary server's IP address. Equally, this information is only required if you want the streamer to access Internet. "Secondary DNS server": Enter the same information for the secondary server. "MAC Address": The physical address of the streamer's ethernet network card is displayed automatically. Once you have filled in all of the required information, click on Modify Network Configuration. If, at the last moment, you decide to keep the current settings, click on Restore. 8
11 Configuration Password If you want to change the current access password, click on the Password tab. The following card is displayed: Figure Password card of the Configuration window. "Current password": Enter the current password. "New password": Enter the new password which will be required to access the program the next time. "Confirm new password": Re-enter the new password. Once you have entered the required information, click on Modify so that the streamer adopts the new access password. If, at the last moment, you decide to keep the previous password, click on Cancel.! Note If you do not know the old password, i.e. the password used to access the current configuration session, you must perform a Password Reset as explained in the Installation and Access manual. Following this reset, the program password will be the default password: admin. IMPORTANT: When you perform a password reset, the IP address assigned to the streamer on the Network card (previous page) automatically changes to the default setting: Shutdown If you need to reboot the streamer for any reason, click on the Shutdown tab. The following card is displayed: Figure Shutdown card of the Configuration window. Click on Reboot. A reset is then performed after which the Output Streams screen will appear, this is the presentation screen of the programme. 9
12 Configuration Update Firmware If you wish to update the streamer's firmware, click on the Update Firmware tab. The card displayed (Figure 1.6) shows the firmware version that the streamer has at the present time. (The firmware is software stored in the module which is responsible for its basic operation). Figure Update Firmware card of the Configuration window. WARNING: The firmware update file will have been previously stored on the PC hard drive. (You can download it from Click on Browse... and select the firmware update file from the hard drive. When the file name is in the box, click on Start. The new firmware will be installed on the streamer and then its name will appear in the card replacing the one of the file before. 10
13 Save/Restore Save/Restore System Settings All of the data established on the streamer module through the various Configuration window tabs can be saved onto a backup file. Inversely, the configuration data saved on an appropriate file can be restored on streamer module. Click on the General menu on the left of the general programme screen and click again on the Save/Restore option. The Save/Restore window will appear: Figure Save/Restore window Save/Restore Configuration "Save configuration": Select the option in the window and click on Start. A window is displayed which allows you to select the destination folder for the data file for the current streamer configuration. "Restore Configuration": Select this option in the Save/Restore window (Figure 1.7) and click on Start. The Restore Configuration window is displayed (Fig. 1.8) Click on Browse... and select the file containing the configuration data that you wish to restore on the streamer module. Once you have selected the file, click on the Upload File button at the bottom of the screen. The upload confirmation window will be displayed. Figure Restore Configuration Window 11
14 General Report General Report Click on the General menu on the left of the general programme screen and click again on the General Report option. The General Report window is displayed: Figure General Report window This window provides complete information on the module, not only regarding the configuration described in the previous pages, but also in relation to the current settings parameter values and operational status. The information contained in this window can be printed by clicking on the Print page button at the bottom of the screen. 12
15 Chapter Two - Streamer Settings In this Chapter DiSEqC Configuration Input Section Settings Output Section Settings SAP Channel Settings User Menu SNMP Configuration 13
16 DiSEqC DiSEqC Configuration The module settings are grouped into six sections or categories: DiSEqC, Input, Output, SAP Channel, User Menu and SNMP. Click on the Settings menu on the left side of the general programme screen. A drop down list is displayed offering six options: DiSEqC, Input, Output, SAP Channel, User Menu and SNMP. Click on DiSEqC. The DiSEqC Configuration window will appear: Figure DiSEqC Configuration window DiSEqC deactivated "ivate DiSEqC" : Check the box if you want to equip the streamer with DiSEqC function, either because you have to feed/control an LNB or because a multiswitch is installed in the headend. Otherwise leave the box unchecked. "Number of inputs" : It refers to the number of SAT inputs of the multiswitch (if there is no multiswitch, and the matter is to feed/control an LNB, choose "4"). When choosing, a multiple pop-up box, with a number of rows equal to the number chosen, appears on the field below (see Figure 2.2). "Description of each input" : If there is no multiswitch and the streamer has to feed/ control an LNB, fill the polarity/band columns with the selections that appear in the first four rows of Figure 2.2. If there is a multiswitch, you have to know what IF signal (satellite, polarisation, band) is connected to each one of the inputs of that one; with this information at hand, fill in all the rows of the box. Figure DiSEqC Configuration window Description of multiswitch inputs Once all data is entered, click on Send to conclude the DiSEqC configuration. 14
17 Input Input Section Settings Click on the Settings menu on the left of the general programme screen and click again on the Input option. The Input window will appear: Figure Input window This window is used to enter the settings values for two parameters (intermediate frequency and input rate) and, if the DiSEqC function is activated, to power an LNB or select an input of multiswitch. The intermediate frequency is the transposed frequency of the desired transponder's frequency. The window has different number of boxes depending on the selection made in the first one ("Setting Mode"), and whether the DiSEqC function is activated or not. "Setting Mode": Select IF if the intermediate frequency value is calculated by the installer, or Transponder if you wish the programme itself make the calculation. IF CALCULATION The streamer's input frequency band is MHz, known as "satellite intermediate frequency" or simply "IF". The value to enter for a particular transponder can be obtained by subtracting the transponder's frequency from the LNB local oscillator frequency. The operational frequencies are the following: - Satellite transponder frequency band: MHz - Local Oscillator frequency on Standard LNB's. Two possible values: 9750 MHz for MHz input frequencies (low band) MHz for MHz input frequencies (high band) - Example of the calculation for FI relating to the WDR program transponder on the Astra satellite: Transponder frequency: MHz IF (intermediate frequency): = 1236 MHz "IF" setting mode is selected: "Satellite signal": Select from the drop down list (see Figure 2.4) either the voltage/ tone signal for feeding/controlling the LNB or the desired input of the multiswitch.! The "Satellite signal" box is shown or not depending on whether the DiSEqC function was activated or not through the DiSEqC option of the Settings menu. Note 15
18 Input Figure Input Window IF Mode "Intermediate Frequency (MHz)": Enter the value calculated for the transposed intermediate frequency of the transponder's frequency in the box. The latter can be found in specialist magazines. "Input Rate (MS/s)": This parameter, best known and Symbol Rate, is also provided in specialist magazines. Enter the value in MS/s (megasymbols per second) or MegaBaud. Once the data is entered, click on Save to conclude the input settings. "Input signal": This indicates whether the streamer module has synchronised ( ) or not ( ) with the input signal. If it has not synchronised, check the different settings values entered. "Transponder" setting mode is selected: Figure Input window Transponder Mode - LNB Standard The window adds 5 auxiliary boxes to those described above for the "IF" setting mode. The programme itself will complete the "Intermediate Frequency (MHz)" box based on the data entered in the mentioned auxiliaty boxes, as indicated next: 16
19 Input "LNB Type": The drop down list has 2 options: Standard LNB and Special LNB. If the LNB installed on the parabolic antenna is standard, select the Standard LNB option. The boxes "Low LO Frequency" and "High LO Frequency" will be automatically completed with values 9750 and respectively (see Figure 2.5 on the previous page). If the LNB installed is Special, select the Special LNB option on the drop down list (see Figure 2.6 below). "Transponder Frequency (MHz)": Enter the required transponder frequency. "Low LO Frequency (MHz)": The value is automatically shown if Standard LNB was selected. You must manually enter this value if you have selected Special LNB. "High LO Frequency (MHz)": As above. "IF Band": Select Low or High from the drop down list depending on the transponder frequency: low for MHz and high for MHz. When the selection is complete the corresponding value will automatically be calculated by the programme and displayed in the Intermediate Frequency box. "Input Rate (MS/s)" : This parameter, best known as Symbol Rate, is also provided in specialist magazines. Once the different data values have been entered, click on Save to conclude the input settings. "Input signal": This indicates if the streamer module has synchronised ( ) or not ( ) with the input signal. If it has not synchronised, check the different settings values entered. Figure Input window Transponder Mode - Special LNB 17
20 Output Output Section Settings Click on the Settings menu on the left of the general programme screen and click again on the Output option. The Output windown will appear: Figure Output window This window is used to select and configure the required services (TV or Radio programs) from the DVB-S input transport stream as IP streams. The window displays three boxes at the top, and in the centre it displays a table showing the IP streams already configured and which may or may not be transmitted by the streamer module (see NOTE below). For each stream it shows the multicast address and the different parameters such as the PID of the main stream or the total bandwidth in Mbps. "Protocol": The drop down menu offers two options : UDP and UDP/RTP. UDP is a transport protocol which is not connection oriented and is particularly useful for streaming. UDP/RTP adds extra data fields so that the data flow is served at the correct speed for its projection in real time. "Time To Live": Is a parameter used to restrict the stream multicasting range. A number between 1 and 255 is entered in this box. Each time that an IP stream passes through a router, the TTL is reduced by one unit. The stream will be rejected by any router when the TTL value is reduced to zero. "QoS": Quality of Service. The drop down list offers five differentiated service options or Diffserv. These options relate to the priority that you wish to assign to the streaming packets on their routes through switches or routers that are QoS management capable: 1 Maximum priority 2 High priority video 3 Low priority video 4 Video and voice 5 Best effort (best effort made to correctly deliver the video data and the associated audio data) NOTE: Configured IP Streams are those that have been created in the manner described on the following page. These streams may or may not be incorporated into the data stream depending on whether their corresponding ON/OFF boxes in the first column are checked or not. The number of checked boxes cannot be higher than 8. 18
21 Output The Output window allows you to perform three actions: - Add Stream: This adds a new IP stream to the display table. - Edit Stream: Allows you to change the parameters of the IP stream on the display table. - Delete Stream: Deletes an IP stream from the display table. Add Stream Click on the Add Stream button at the bottom of the Output window (see Figure 2.7 on the previous page). The Add Stream window is displayed: Figure Add Stream window The window shows all of the input DVB-S transport stream services, including different details (name, type, identifier, main PID, provider). Highlighted in orange are those services which are already configured as IP streams (seen in the display table in the Output window) and highlighted in green are those which are not yet configured. To add a stream to the display table, select the button for the corresponding service in the first column. The line will be highlighted in pink and a group of boxes related to the elemental streams associated to the main stream of the service will appear. The boxes at the top and middle of the screen will now be completed, and the elemental streams at the bottom will be configured: 19
22 Output Boxes at the top of the screen: "Multicast Stream Address": Enter the multicast address required for the stream to be added. The available range is from to , but it is recommended to reduce it from to See NOTE below. "Port": The default value is "SAP ID": Is the name given to the service on the subscriber's set-top box or reproducer, if the device supports SAP/SDP protocol. The name that the service has on the input transport stream is the default name. "Channel Number": Enter the order number you want to assign to the service on the subscriber's set-top box or reproducer, if the device supports SAP. "SAP Group": Select from the drop down menu the SAP group to which you want to link the service. The group will have been previously created through the SAP/SDP Channel window (see next page). Box in the middle of the screen: "Send full PMT": Leave this box checked if you wish to send the complete PMT table (Program Map Table) for the service. Otherwise, if you would like to refrain from sending certain PIDs that are not relevant to the elemental streams associated with the main stream (bottom boxes) remove the check from the box. Bottom boxes: Only in cases where the "Send full PMT" box is NOT checked can you make the selections that you wish on each of the elemental streams associated with the main stream: audio, subtitles, teletext, etc. Once all data is entered and the appropriate selections have been made, click on Update to add the new IP stream to the display table in the Output window. Edit Stream: You can change the parameters of an IP stream displayed in the table on the Output window. Click on the icon at the end of the line. The previously described Add Stream screen is displayed, where you can change any editable field, from the multicast address to the elemental stream selections in the boxes at the bottom. Once all changes that you require are made, click on Update and the IP stream will be displayed with its new configuration in the display table in the Output window. Delete Stream: If you wish, you can delete an IP stream from the display table on the Output window. To do so, click on the icon at the end of the line. NOTE : Range through is reserved for local purposes (as administrative and maintenance tasks). Datagrams destined to this use are never forwarded by multicast routers. Similarly, the range to has been reserved for "administrative scoping" (administratively defined topological regions). 20
23 SAP/SDP Channel SAP Channel Settings Click on the Settings menu on the left of the general programme screen and click again on the SAP Channel option. The SAP Channel window will appear: Figure SAP Channel window This menu option is used to configure the announcement and service description SAP/ SDP channel. SAP and SDP are two protocols for creating an EPG type program guide. "SAP ivated": Check the box if you wish to transmit the program guide. "SAP IP address": This data cannot be changed. It is the IP address assigned to the streamer module on the Network tab in the Configuration window (page 8). "Username": The name entered will be transmitted on the SAP/SDP channel. "Group": As above. "Time interval between SAP announcements": Introduce the time interval, in seconds, at which the transmitted programmes guide will refresh. Click on Save to save the SAP/SDP channel configuration data. 21
24 User Menu User Menu of the Conditional Access Module () Click on the Settings menu on the left of the general programme screen and click again on the User Menu. The User Menu window will appear : Figure User Menu window Click on the Begin Conditional Access Session button. A window showing a menu whose content depends on the inserted module will appear. Figure 2.11 below shows as an example the menu presented by a particular Mediaguard. Independently of the type, the different options of the initial menu are always numbered, so that the access to these is accomplished through the PC keyboard. Carrying on with the example, to accede to the Card option you must press the key "1" of the keyboard (number 1 will be shown in the lower box, see Figure 2.12) and next you must click on the Send button. The window of Figure 2.13 appears. This window, besides to inform about the card serial number and the stored maturity level, allows to change this level through the Change Maturity option, via keyboard and Send button, as explained. Figure 2.11 Figure 2.12 Figure 2.13 The way to accede to the different options of the menu has been clear, so it is not necessary to follow with the example. The procedure is, as aforesaid, similar for all type of modules. When in doubt, contact the vendor of the module.! Note The correct programme de-encrypting is guaranteed only with s validated by IKUSI. Consult on the operativity of your. 22
25 SNMP SNMP Configuration Click on the Settings menu on the left of the general programme screen and click again on the SNMP option. The SNMP Agent window will appear: Figure SNMP Agent window This window is used to configure the notification of determined traps the SNMP manager (management station). It has two sections: Configuration and Traps. Configuration Section : "MIB" : Click on Download to download the MIB of the streamer. "SNMP Agent" : Tick the box if you want to activate the SNMP agent implemented in the streamer module. "SNMP Manager IP" : Enter the IP address of the manager. "Community" : Enter the desired name for the group formed by the streamers and power supplies of the present SNS headend, and by the manager. "ivate CFP-702" : Tick the box in the case the streamer module is linked to a CFP-702 power supply and you want to integrate this into the management system. (See Fig on next page). "Identify CFP-702" : Enter a name for the CFP-702 linked to the present streamer module. "Minimum Alarm Duration" : Enter the minimum duration in seconds of an alarm event so that it be considered as such by the SNMP manager. "Send Traps Continuously" : Tick the box if you want that to an alarm event the related trap be sent repeatedly to the manager. If this box is ticked, the two next ones are disabled. "Trap Sendings" : Enter the times to an alarm event you want to send the corresponding trap to the manager. "Time between Sendings" : It is related to the box before. Enter the time in seconds between the trap sendings. "Time Sending Traps with ACK" : It is applicable to traps with ACK enabled. Enter the maximum time in seconds to an alarm event the trap will be being sent continuously until having an acknowledgement from the manager. 23
26 POWER ITOT (MAX) +24V +18V 300 ma (22 KHz) +13V 300 ma (22 KHz) +18V 300 ma +13V 300 ma :700 ma POWER ITOT (MAX) +24V +18V 300 ma (22 KHz) +13V 300 ma (22 KHz) +18V 300 ma +13V 300 ma :700 ma SNMP Traps Section : You select here the streamer parameters whose alarm status generate traps, either with or without acknowledgement. "Hardware" : Tick the box for sending an alarm trap when there be an anomaly in the streamer's circuitry. If you want to receive an acknowledgement from the SNMP manager, tick also the Enable ACK box at right. "Input" : Idem when there be no synchronisation with the input signal. "DiSEqC" : Idem when the DiSEqC fonction is not available or doesn't work. "" : Idem when the module doesn't work properly or is not installed. "ColdStart" : Idem when there be a Cold Start (the power is turned off then back on). "WarmStart" : Idem when the module is rebooted (through the Shutdown card of the Configuration window, see page 9). "CFP Temperature" : It is applicable only if the streamer module is linked to a CFP- 702 power supply, with the object of incorporating this to the SNMP system. It is related to the internal temperature of the power supply. Tick the box so that the alarm trap be transmitted when this temperature exceedes the established limits. "CFP Voltage" : Idem in relation to the output voltage of the power supply. "Status" : Tick the box for sending a "summary" trap with the current status of the most outstanding parameters. "Time between Sendings" : This box is enabled only if you ticked the previous one. Enter the desired time in seconds to pass between "summary" trap sendings. CFP-702 CFP-702 monitoring jumper monitoring jumper Figure Example of SNS Headend with monitor redundant power system. Contains 7 streamers and 2 CFP-702 power supplies. 24
27 Chapter Three - Streamer Status Information In this Chapter Status Information 25
28 Status Information Status Information Click on the Status menu on the left of the general programme screen and click again on the Status Information option. The Status Information window appears: Figure Status Information window This window gives you information on the existence of alarms for module operations and on the importance reception and transmission parameters: "Hardware Alarm" : Indicates whether there is an anomaly in the module's circuitry. A mark indicates correct status or operations and a cross warns of an alarm situation. "Input": Indicates whether there is ( ) synchronisation or not ( ) with the input signal. In cases where there is not synchronisation, check the settings made in the Input Settings (pages 15 to 17). "": Indicates whether the module works properly ( ) or either it doesn't work properly or no is installed ( ). "DiSEqC": Indicates whether the DiSEqC function is available in the module ( ), being it activated or not, or either it is not available or it doesn't work ( ). "BER": Expresses in scientific notation the channel BER value for the input signal. "C/N (db)": The value in db of the carrier/noise ratio of the input signal. "Number of Streams": Number of IP streams currently transmitted by the module. "Output Rate": Value in Mbps. "Information Sent (MB)": Expresses in scientific notation, the amount of information (in megabytes) which has been transmitted by the internal web server since the last module reset. "Information Received (MB)": The same for information received. 26
29 Chapter Four - Streamer Reports In this Chapter Input Services Output Streams System Logs 27
30 Input Services Input Services Click on the Reports menu on the left of the general programme screen and click again on the Input Services option. The Input Services window appears: Figure Input Services Window The Input Services window shows the full information on each of the services contained in the DVB-S input transport stream. In particular, it specifies the values of the following parameters for each service: - Name of the service - Type - SID (service identifier) - PID of the main stream - Service Provider - PID, Type and Language of each one of the elemental streams associated with the main stream 28
31 Output Streams Output Streams Click on the Reports menu on the left of the general programme screen and click again on the Output Streams option. The Output Streams window will appear: Figure Output Streams window The Output Streams window shows all IP streams that have been created for this module. These streams may or may not be incorporated in the output data stream. For each IP it shows the following details: - ON/OFF (whether the stream is incorporated or not in the output data stream) - IP Stream (multicast address) - SID (service identifier) - PID of the main stream - Name of the service - Type - Total output bandwidth in Mbps - SAP ID (name with which the service is announced on the subscriber's receiver) - Service Provider - PID, Type and Language of each one of the elemental streams associated with the main stream, indicating whether they are incorporated into the IP output transport stream or not. 29
32 System Logs System Logs Click on the Reports menu on the left of the general programme screen and click again on the System Logs option. The System Logs window will appear: Figure System Logs window 30
33 IKUSI - Ángel Iglesias, S.A. Paseo Miramón, San Sebastián SPAIN Tel.: Fax: ER-0149/1996
34 EC-Declaration of Conformity marking We, Manufacturer IKUSI, Angel Iglesias, S.A. Paseo Miramón, 170 E San Sebastián, Spain declare that the product DVB-S IP Streamer with Common Interface E M C is in conformity with Council Directive 89/336/EEC (EMC Directive) Standards to which conformity is declared : x x EN 55022:1998 EN 55024:1998 Information Technology Equipment. Radio disturbance characteristics. Limits and methods of measurement. Information Technology Equipment. Inmunity characteristics. Limits and methods of measurement. San Sebastián, July 03/2007 Marco A. Domínguez R&D Manager
35 Ref POWER SUPPLY POWER +24V 60mA 5A V LNB V LNB IKUSUP V LNB V LNB V LNB V LNB COMMON INTERFACE () SNS-102 (Ref. 5113) S IP DVB-S/S2 FTA o MULTICRYPT A IP IP S FTA or MULTICRYPT DVB-S/S2 TO IP S IP DVB-S/S2 FTA ou MULTICRYPT VERS IP MANUAL DE INSTALACION Y ACCESO / INSTALLATION AND ACCESS GUIDE / NOTICE D'INSTALLATION ET ACCÈS SNS-102 Recepción / Reception / Réception DVB-S (QPSK) DVB-S/S2 (QPSK, 8PSK) APLICACION Los streamers SNS son pasarelas DVB-S ó DVB-S2 a IP diseñadas para difundir en multicast sobre una red IP los servicios (cadenas TV y Radio) procedentes de recepción satélite digital en abierto o encriptada. Los streams IPTV pueden ser visionados mediante un set-top box o un software reproductor de vídeo. MANUAL DE CONFIGURACION Y AJUSTE Disponible en formato PDF en Estaciones «SNS» Una estación modular SNS incluye tantos streamers como transpondedores DVB-S/S2 haya cuyos servicios se desee transmitir a la red IP, y uno o más módulos de alimentación. Deberá insertarse un módulo con la tarjeta de operador en aquellos streamers que reciban una o más cadenas encriptadas que se desee desencriptar. Los módulos se montan en las bases-soporte de fijación mural BAS-700 / BAS-900 ó en el soporte-rack SMR-601. A través de los puertos RJ-45 de salida un puerto por streamer la estación proporciona a la red IP hasta 8 x n servicios encapsulados IP, siendo n el número de módulos streamers instalados en la estación. Los streamers y SNS-102 están equipados con función DiSEqC. APPLICATION The SNS streamers are DVB-S or DVB-S2 to IP gateways designed to broadcast in multicast on an IP network the services (TV and Radio programmes) issued from FTA or Multicrypt digital satellite reception. The IPTV streams can be viewed using a set-top box or a software video player. CONFIGURATION AND SETTING MANUAL Available on PDF format on «SNS» Headends A modular SNS headend includes as many streamers as there are DVB-S/S2 transponders whose services you want to broadcast on the IP network, and one or more power supplies. A containing the operator's smart card must be inserted into the streamers that receive one or more encrypted programmes that you want to deencrypt. The modules are placed on the wall-fixing BAS-700 / BAS-900 baseplates or in the SMR- 601 rack-frame. The RJ-45 output ports of the headend one port per streamer feed the IP network with up to 8 x n IP-encapsulated services, being n the number of streaming modules installed in the headend. The and SNS-102 streamers are equipped with DiSEqC function. APPLICATION Les streamers SNS sont passerelles DVB-S ou DVB-S2 vers IP dessinées pour diffuser en multicast dans un réseau IP les services (chaînes TV et Radio) en provenance de réception satellite numérique en clair ou cryptée. Les streams IPTV peuvent être visionnés avec une set-top box ou un logiciel lecteur de vidéo. MANUEL DE CONFIGURATION ET REGLAGE Disponible en format PDF sur Stations «SNS» Une station modulaire SNS inclut autant de streamers qu'il y ait de transpondeurs DVB- S/S2 dont les services on désire transmettre sur le réseau IP, et un ou plus de modules d'alimentation. On devra insérer un module avec la carte d'opérateur dans les streamers que reçoivent une ou plusieurs chaînes cryptées qu'on veut décrypter. Les modules sont montés sur les platines à fixation murale BAS-700 / BAS-900 ou dans le cadre-rack SMR-601. À travers les ports RJ-45 de sortie un port par streamer la station rapporte au réseau IP jusqu'à 8 x n services encapsulés IP, étant n le nombre de modules streamers installés dans la station. Les streamers et SNS-102 sont équipés avec fonction DiSEqC. CFP-500 Estación SNS de fijación mural para 6 transpondedores TV Satélite Digital. Contiene 6 streamers y 1 Alimentador CFP-500. La estación puede suministrar a la red IP hasta 48 streams IPTV multicast. SNS wall-fixing headend for 6 Digital Satellite TV transponders. Contains 6 streamers and 1 CFP-500 Power Supply. The headend can feed the IP network with up to 48 multicast IPTV streams. Station SNS de fixation murale pour 6 transpondeurs TV Satellite Numérique. Contient 6 streamers et 1 Alimentation CFP-500. La station peut fournit au réseau IP jusqu'à 48 streams IPTV multicast. ACCESORIOS SUMINISTRADOS / ACCESSORIES SUPPLIED / ACCESSOIRES FOURNIS - Con cada módulo streamer SNS se suministran 2 puentes : - Each SNS streaming module is packed with 2 bridges : - Chaque module streamer SNS est livré avec 2 ponts : Puente coaxial F F plug bridge Pont F Puente DC DC plug bridge Cavalier CC 1
36 DESCRIPCION DE PANEL / PANEL DESCRIPTION / PRESENTATION DU MODULE Lazo derivación entrada FI-Sat Sat-IF input tap-loop Boucle dérivation entrée BIS Hembrilla telealimentación LNB LNB power socket Embase téléalimentation LNB Puerto DB-9 para conexión de un terminal DB-9 port for connection of a terminal unit Port DB-9 pour la connexion d'un terminal LEDs de control Control LEDs LEDs de contrôle Hembrillas cascada alimentación DC DC power cascade sockets Embases cascade alimentation CC Puerto RJ-45 - Salida stream IP RJ-45 port - IP stream output Port RJ-45 - Sortie stream IP LEDs de control Control LEDs LEDs de contrôle LINK ACT Slot para Slot for Slot pour (Conditional Access Module) Conax, Cryptoworks, Irdeto, KeyFly, Mediaguard, Nagravision, Viaccess, etc. RJ-45 port (Tx +) 2 (Tx -) 3 (Rx +) 6 (Rx -) 4, 5, 7, 8 (N/C) INDICADORES LED Las indicaciones del led deben atenderse cuando haya terminado el proceso de ajuste del streamer. - Si luce verde permanente, el stream IP de salida es correcto. - Si parpadea verde, no se ha adquirido la señal de entrada. - Si está apagado y el led parpadea rápido rojo: error de firmware. - Si permanece apagado, el hardware funciona correctamente. - Luce rojo mientras el módulo está ejecutando una operación. - Si luce rojo permanente, hay una alarma de funcionamiento o el módulo está defectuoso. LED INDICATORS Indications of the led must be attended when the setting process of the streamer is finished : - If it lights green permanently, the output IP stream is correct. - If it flashes green, the streamer has not acquired the input signal. - If it is off and the led flashes red quickly: firmware error - If it is off, the hardware works correctly. - It lights red while the module is carrying out an operation. - If it lights permanently red, there is an operatigng alarm or the module is damaged. INDICATEURS LED Les indications de la led doivent être considérées seulement quand le réglage du module soit terminé : - Si s'illumine verte en permanence, le stream IP de sortie est correct. - Si clignote verte, le streamer n'a pas acquis le signal d'entgrée. - Si est éteinte et la led clignote rapidement rouge : erreur de firmware. - Si est éteinte, le hardware marche correctement. - S'illumine rouge pendant que le module est exécutant une opération. - Si s'illumine rouge en permanence, il y a une alarme de fonctionnement ou le module est défectueux. LINK - Luce verde permanente si hay enlace ethernet. - Si está apagado, no hay enlace ethernet. ACT - Parpadea verde cuando hay actividad ethernet. - Si está apagado, no hay actividad ethernet. LINK - It lights green permanently if there is ethernet link. - If it is off, there is not ethernet link. ACT - If flashes green when there is ethernet activity. - If it is off, there is not ethernet activity. LINK - S'illumine verte en permanence s'il y a de liaison éthernet. - Si est éteinte, il n'y a pas de liaison éthernet. ACT - Clignote verte quand il y a d'activité éthernet. - Si est éteinte, il n'y a pas d'activité éthernet. 2
37 Especificaciones técnicas / Technical specifications / Données techniques Frecuencia de entrada Input frequency Fréquence d'entrée Equipado con DiSEqC DiSEqC equipped (vers. 1.08) Équippé avec DiSEqC No. máx de programas desencriptados Max number of de-encrypted services Nombre max de programmes décryptés Nivel de entrada Input level Niveau d'entrée Ganancia lazo de entrada Input loop-through gain Gain boucle d'entrée Velocidad de símbolo de entrada Input symbol rate Débit de symbole d'entrée ( * ) Corriente máx: 300 ma Max current: 300 ma Courant max : 300 ma MHz Sí / Yes / Oui ( * ) Variable ( depending) dbm 0 (±3) db MS/s Velocidad de bit de salida Output bit rate Débit de sortie Número de streams simultáneos de salida Number of simultaneous output streams Nombre de streams simultanés de sortie Tipo de dirección IP de los streams IP address type of the streams Type d'adress IP des streams Tensión de alimentación Power voltage Tension d'alimentation Consumo (sin/con ) ( Consumption (without/with ) ** ) Consommation (sans/avec ) Temperatura de funcionamiento Operating temperature Températures de fonctionnement 100 Mbps 8 Multicast +12 VDC 310 / 480 ma (DVB-S) 620 / 790 ma (DVB-S2) C ( ** ) Añadir, si procede, el consumo de la LNB telealimentada. Add up, if befitting, the consumption of the LNB powered. Ajouter, s'il y a lieu, la consommation du LNB téléalimenté. Características Entrada: 1 señal de transpondedor DVB- S/S2 con servicios (cadenas TV o Radio) en abierto o encriptados. Salida: hasta 8 servicios simultáneos, encapsulados IP, con direcciones individuales multidifusión. Filtrado de la información contenida en las tablas DVB. Protocolos de transmisión UDP y RTP. Interfaz web de configuración. Agente SNMP de información de alarmas. Protocolos SAP y SDP para selección automática de cadena en el STB y suministro de información de programa a servidores externos. CARACTERISTICAS AVANZADAS Filtrado PID Análisis PSI/SI Paso transparente mensajes ECM y EMM Regeneración de tablas PAT y PMT Paso o bloqueo de tablas CAT, NIT, SDT, EIT, TDT Marcado QoS configurable TTL configurable Features Input: 1 DVB-S/S2 transponder signal with FTA or encrypted services (TV or Radio programmes). Output: up to 8 simultaneous IP-encapsulated services with individual multicast addresses. Filtering of information contained in the DVB tables. UDP and RTP transmission protocols. Web interface for module configuration. Alarm information SNMP agent. SAP and SDP protocols to facilitate automatic programme selection in the settop box and to provide programme information to external servers. ADVANCED FEATURES PID filtering PSI/SI parsing ECM and EMM transparent passthrough Regeneration of PAT and PMT tables Passthrough or blockade of CAT, NIT, SDT, EIT and TDT tables QoS marking configurable TTL configurable Caractéristiques Entrée : 1 signal de transpondeur DVB-S/ S2 avec des services (chaînes TV ou Radio) en clair ou cryptés. Sortie : jusqu'à 8 services simultanés, encapsulés IP, avec adresses individuelles multicast. Filtrage du renseignement contenu dans les tables DVB. Protocoles de transmission UDP et RTP. Interface web pour la configuration. Agent SNMP de renseignement d'alarmes. Protocoles SAP et SDP pour sélection automatique de chaîne sur la STB et fourniture de renseignement de programme à serveurs externes. CARACTÉRISTIQUES AVANCÉES Filtrage PID Analyse PSI/SI Passage transparent messages ECM et EMM Régénération de tables PAT et PMT Passage ou blocage de tables CAT, NIT, SDT, EIT, TDT Marquage QoS configurable TTL configurable ASI : Asynchronous Serial Interface. Serial transmission method for MPEG-2 streams. CAT : Conditional Access Table ECM : Entitlement Control Messages EIT : Event Information Table EMM : Entitlement Management Messages IPTV : Internet Protocol Television MPTS : Multiple Program Transport Stream NIT : Network Information Table PAT : Program Association Table PID : Packet IDentifier PMT : Program Map Table PSI : Program Specific Information QoS : Quality of Service RTP : Real-Time Transport Protocol SAP : Service Advertisement Protocol SDP : Session Description Protocol SDT : Service Description Table SI : Service Information SNMP : Simple Network Management Protocol SPTS : Single Program Transport Stream TDT : Time and Date Table TTL : Time to Live UDP : User Datagram Protocol i Para una correcta visualización de los gráficos proporcionados por el programa de configuración del streamer, se recomienda instalar en el PC de control el navegador web Mozilla FireFox. ( For correct visualization of the diagrams generated by the streamer configuration programme, it is advisable to install in the control PC the Mozilla FireFox web browser. ( Pour une correcte visualisation des schémas générés par le programme de configuration du streamer, il est recommendable d'installer dans le PC de contrôle le navigateur web Mozilla FireFox. ( 3
38 CFP-500 Ref POWER SUPPLY POWER +24V 60mA INSERCIÓN DE Y TARJETA INSERTING AND SMART CARD INSERTION DU ET DE LA CARTE contactos contacts contacts borde ancho thick rim bord épais TARJETA DEL OPERADOR OPERATOR'S SMART CARD CARTE DE L'OPÉRATEUR ORDENAMIENTO DE LOS MÓDULOS / PLACING THE MODULES / EMPLACEMENT DES MODULES Las figuras muestran la disposición de los módulos en dos estaciónes SNS. El módulo alimentador debe colocarse en uno de los extremos del montaje. The pictures show the layout of the modules in two SNS headends. The power supply module must be placed at one of the ends of the assembly. Les figures montrent l'emplacement des modules dans deux stations SNS. Le module d'alimentation doit être placé dans l'un des bouts de l'ensemble. ALIMENT. / POWER SUPPLY SNS SNS SNS BAS-700 SNS SNS SNS SNS SNS SNS SNS SNS BAS-900 SNS SNS SNS ALIMENT. / POWER SUPPLY FIJACIÓN DE LOS MÓDULOS EN LAS BASES-SOPORTE FITTING THE MODULES TO THE BASE-PLATES FIXATION DES MODULES SUR LES PLATINES base-soporte base-plate platine FIJACION FITTING FIXATION DESMONTAJE REMOVING DÉMONTAGE FIJACIÓN DE LOS MÓDULOS EN EL MARCO-RACK FITTING THE MODULES TO THE RACK-FRAME FIXATION DES MODULES SUR LE CADRE-RACK OMR-601 PMR-601 marco-rack rack-frame cadre-rack marco-rack SMR-601 rack-frame cadre-rack 4
39 POWER SUPPLY POWER Ref V 60mA 5A 5A CFP-500 Ref POWER +24V 60mA 5A Power AUX INPUT Gain 5 db CONEXION DE LA SEÑAL FI-SAT / CONNECTION OF THE SAT-IF SIGNAL / RACCORDEMENT DU SIGNAL BIS a) Instalando líneas de derivación / Installing tap-lines / En installant des lignes de dérivation Se creará 1 línea de derivación para cada grupo de streamers que vayan a hacer uso de la misma señal FI de entrada (satélite-polarización-banda). La función DiSEqC deberá activarse necesariamente en aquellos streamers que reciban los cables de bajada (con LNBs tipo "quattro", sólo en el streamer que deba proporcionar la corriente de telealimentación). 1 tap-line must be created for each group of streamers that are going to use the same IF input signal (satellite-polarisation-band). The DiSEqC function will have to be compulsorily activated on the streamers that receive the down-lead cables (avec "quattro" type LNBs, only on the streamer that have to provide the remote powering). On créera 1 ligne de dérivation pour chaque groupe de streamers allant utiliser le même signal BIS d'entrée (satellite-polarizationbande). La fonction DiSEqC devra être activée nécessairement dans les streamers que reçoivent les câbles de descente (avec LNBs type "quattro", seulement dans le streamer que doive procurer le courant de téléalimentation). LNB universal LNB twin universal LNB "quattro" DiSEqC 75W DiSEqC 75W DiSEqC 75W DiSEqC (+13 V) 75W 75W 75W 75W RECORDAR: 1. La corriente DiSEqC máxima de cada módulo streamer es 300 ma. 2. Los consumos de las LNBs deben tenerse en cuenta a la hora de calcular el consumo total (a +12 VDC) de la estación SNS. REMEMBER: 1. The maximum DiSEqC current from each streamer module is 300 ma. 2. The consumptions of the LNBs must be taken into account when calculating the total consumption (at +12 VDC) of the SNS headend. RAPPELER : 1. Le courant DiSEqC maximal de chaque module streamer est 300 ma. 2. Les consommations des LNBs doivent être considérées pour le calcul de la consommation totale (à +12 VCC) de la station SNS. b) Utilizando multiswitches Using multiswitches En utilisant des commutateurs matriciels LNB "quattro" LNB "quattro" Multiswitch - La función DiSEqC deberá activarse en todos los streamers. - The DiSEqC function will have to be activated on all the streamers. - La fonction DiSEqC devra être activée dans tous les streamers. carga 75W en cada streamer 75W load on every streamer charge 75W sur chaque streamer Ethernet Switch INSTALACION PUENTES +12 VDC / INSTALLING DC BRIDGES / INSTALLATION CAVALIERS +12 VCC Módulo de Alimentación Power Supply Alimentation CFP-500 5
40 CFP-500 Ref POWER SUPPLY POWER +24V 60mA 5A ACCESO LOCAL A LOS S Una vez instalada la estación SNS, deberán configurarse y ajustarse ( * ) uno por uno todos los módulos streamers que la componen. El proceso debe llevarse a cabo en modo local, aun cuando posteriormente se podrá acceder a cada módulo desde cualquier PC de la para comprobar su estado de funcionamiento, o variar su configuración y ajuste, u obtener informes diversos. Para el acceso local a los módulos se utilizará un PC con tarjeta de red Ethernet y un cable ethernet CAT-5E cruzado. El PC debe estar configurado con los siguientes parámetros de Propiedades de TCP/IP: Dirección IP del PC : Máscara de subred : Empezar por el primer módulo. Conectar el PC a su puerto (RJ-45) de salida (ver figura abajo). Iniciar el navegador web e introducir la dirección IP inicial de fábrica que tienen todos los streamers : Dirección IP inicial : Pulsar INTRO. Aparece la pantalla de presentación del programa de configuración y ajuste (ver abajo derecha), en la que debe introducirse la clave de acceso inicial de fábrica: Clave de Acceso inicial: admin Pulsar INTRO. Se muestra la pantalla inicial del programa. IMPORTANTE Las mencionada dirección IP inicial de cada streamer deberá ser cambiada desde el programa por otra cuya sección subred sea la de la. Se recomienda cambiar asimismo la clave inicial de acceso al programa. Las nuevas direcciones IP de los streamers y la clave de acceso al programa de configuración y ajuste deberán ser anotadas en sitio seguro para evitar tener que hacer un reset de acceso (ver en página siguiente) cuando se pretenda acceder a los módulos y se desconozcan las actuales direcciones IP de los mismos y/o la clave de acceso al programa. *El proceso de configuración y ajuste se explica en el manual correspondiente disponible en LOCAL ACCESS TO THE S After installing the SNS headend, you must configure and set ( * ) one after the other the streaming modules that make up the headend. The process will be carried out in local mode, even if you will be able to accede later to each module from any PC of the in order to check its operating status, to change its configuration and setting, or to obtain diverse reports. For local access to the modules you must use a PC provided with Ethernet adapter and a crossover CAT-5E ethernet cable. The PC must be configured with the following parameters of TCP/IP Properties: IP address : Subnet mask : Open with the first module. Connect the PC to its output port (see figure below). Start the web browser and enter the initial factory IP address that have all streamers : Initial IP address : Press INTRO. The programme presentation screen of the configuration and setting programme appears (see below at right). Then type the initial factory access key: Initial access key: admin Press INTRO. The initial screen of the programme is shown. IMPORTANT The aforementioned initial IP address of each streamer must be changed through the programme into another whose subnet section be that of the. It is advisable to change as well the initial access key for accesing to the programme. The new IP addresses of the streamers and the programme access key must be noted in a safe place in order to spare to have to do an access reset (see on next page) when you want to accede the modules and you don't know the current IP addresses of them and/or the access key of the programme. * The configuration and setting process is explained in the corresponding manual available on ACCÈS LOCAL AUX S Une fois installée la station SNS, on devra configurer et régler ( * ) un à un les modules streamers qui la composent. Le processus sera réalisé en mode local, bien que postérieuremet on pourra accéder à chaque module depuis un PC quelconque du réseau pour vérifier son état de fonctionnement, modifier son configuration et réglage, ou obtenir renseignements divers. Pour l'accès local aux modules on devra utiliser un PC avec carte Ethernet et un câble éthernet CAT-5E croisé. Le PC doit être configuré avec les suivants paramètres de Propriétés TCP/IP : Adresse IP du PC : Masque de sous-réseau : Commencer par le premier module. Connecter le PC au port (RJ-45) de sortie du premier module streamer (voir figure en bas). Initier le navigateur web et saisir l'adresse IP initiale que ont tous les streamers : Adresse IP initiale : Taper INTRO. L'écran de présentation du programme de configuration et réglage (voir ci-dessous à droite) apparaît. Saisir le mot de passe initial d'usine : Mot de Passe initial: admin Taper INTRO. L'écran initial du programme est montré. IMPORTANT La mentionnée adresse IP initiale de chaque streamer doit être changée depuis le programme par une autre dont la section sousréseau soit celle du. De même il est recommendable changer le mot de passe initial d'accès au programme. Les nouveaux adresses IP des streamers et le mot de passe d'accès au programme doivent être notés dans un place sûr afin d'éviter devoir faire un reset d'accès (voir à la page suivante) quand l'on prétende accéder aux modules et ne l'on connaisse pas les actuelles adresses IP de ceux-ci et/ou le mot de passe d'accès au programme. * Le processus de configuration et réglage est expliqué dans le manuel correspondant disponible sur ethernet CAT-5E (crossover) Pantalla de presentación del programa Programme presentation screen Écran de présentation du programme 6
41 Reset de acceso Cuando hay que acceder a un módulo streamer, y se desconocen su dirección IP y/o la clave de acceso al programa, la única salida es restaurar los valores iniciales de fábrica señalados en la página anterior. Para la restauración se precisa un PC y un programa de comunicaciones tal como HyperTerminal de Windows. Conectar el PC al puerto del panel frontal del módulo, mediante un cable DB-9 Null Modem (ver figura abajo). Iniciar HyperTerminal y configurar la conexión con los siguientes parámetros: - Formato: asíncrono - Velocidad: bps - 8 bits - 1 bit de parada - No paridad - Control flujo: ninguno Conectar: i) login: reset ii) password: reset Aparece un mensaje anunciando que se han restaurado la Dirección IP y la Clave de Acceso iniciales de fábrica (ver página anterior). Hacer reset desconectando y conectando la alimentación del módulo. Access reset When you have to accede a streaming module, and its IP address and/or the programme access key are unknown, the only solution is to restore the initial factory values pointed on the previous page. For restoring you need a PC and a communication programme such as HyperTerminal from Windows. Connect the PC to the port at the front panel of the module, by using a Null Modem DB-9 cable (see figure below). Start HyperTerminal and configure the connection with the following parameters: - Format: asynchronous - Bit rate: bps - 8 bits - 1 stop bit - No parity - Control of stream: none Connect: i) login: reset ii) password: reset A message announcing that the initial factory values for IP Address and Access Key (see previous page) have been restored appears. Reset the module by switching on-off the power. Reset d'accès Quand il faut accéder à un module streamer, et son adresse IP et/ou le mot de passe du programme sont inconnus, l'unique solution est restaurer les valeurs initiales d'usine signalées à la page précédente. Pour la restauration on demande un PC et un programme de communications tel que l'hyperterminal de Windows. Connecter le PC au port à la face avant du module, par l'intermédiaire d'un câble DB-9 Null Modem (voir figure en bas). Initier HyperTerminal et configurer la connexion avec les paramètres suivants : - Format: asynchrone - Débit: bps - 8 bits - 1 bit de stop - Non parité - Contrôle écoulement: aucun Connecter: i) login: reset ii) password: reset Un message apparaît en annonçant que l'adresse IP et le Mot de Passe initials d'usine (voir page précédente) ont été restaurés. Faire reset en déconnectant et connectant l'alimentation. DB-9 null modem 7
42 POWER SUPPLY POWER +24V 60mA 5A Power CONEXION A LA RED La conexión de la estación SNS a la red se lleva a cabo a través de un switch ethernet al cual se conectará el puerto (RJ-45) de salida de cada streamer utilizando cables ethernet CAT-5E. CONNECTION TO THE Connection of the SNS headend to the is carried out through an ethernet switch to which you must connect the port (RJ- 45) of each streamer using CAT-5E ethernet cables. CONNEXION AU RÉSEAU La connexion de la station SNS au réseau est effectuée à travers d'un switch (commutateur) éthernet auquel on doit raccorder le port (RJ-45) de sortie de chaque streamer en utilisant câbles éthernet CAT-5E. CFP-500 Ref Ethernet Switch Acceso a los streamers desde la El acceso a cada módulo streamer de la cabecera puede llevarse a cabo desde cualquier PC de la introduciendo en el navegador web la dirección IP que se ajustó para aquél. Pulsar INTRO. Aparece la pantalla de presentación del programa de configuración y ajuste (ver abajo), en la que debe introducirse la clave de acceso ("admin" u otra si es que se cambió posteriormente). Pulsar INTRO. Aparece la página inicial del programa. Access to the streamers from the You can accede to each streaming module of the headend from any PC of the. Enter into the web browser the IP address that was set for that module. Press INTRO. The programme presentation screen of the configuration and setting programme appears (see below). Then type the access key ("admin" or another if it was changed later on). Press INTRO. The initial page of the programme appears. Accès aux streamers depuis le L'accès à chaque module streamer de la station peut être effectué depuis un PC quelconque du réseau. Saisir dans le navigateur web l'adresse IP qui fut réglée pour le module. Taper INTRO. L'écran de présentation du programme de configuration et réglage (voir ci-dessous) apparaît. Saisir le mot de passe ("admin" ou un autre s'il fut changé postérieurement). Taper INTRO. La page initiale du programme est montrée. Pantalla de presentación del programa Programme presentation screen Écran de présentation du programme IKUSI Ángel Iglesias, S.A. Paseo Miramón, San Sebastián - SPAIN Tel.: Fax: ER-0149/ D
RNS-101 IP Streamer Sat Radio to IP multicast
IP Streamer Sat Radio to IP multicast Multicast streamer for IP broadband networks. Up to twenty-eight simultaneous satellite radio programs encoded for IP streaming over IP multicast networks. Designed
TNS-101 IP Streamer DVB-T FTA/MultiCrypt to IP
IP Streamer DVB-T FTA/MultiCrypt to IP Multicast streamer for IP broadband networks. Up to eight simultaneous DVB-T terrestrial digital television programs for Free-To-Air (FTA) or MuliCrypt encoded for
SNS-100 IP Streamer DVB-S FTA to IP multicast
IP Streamer DVB-S FTA to IP multicast Multicast streamer for IP broadband networks. Up to eight simultaneous DVB-S satellite television programs for Free-To-Air (FTA) encoded for streaming over IP multicast
(Television on IP Networks)
POWER ITOT (MAX) +24V +18V 300 ma (22 KHz) +13V 300 ma (22 KHz) +18V 300 ma +13V 300 ma :700 ma Ref. 5100 Ref. 5100 Ref. 5100 Ref. 5100 Ref. 5100 Ref. 5100 DVB IP Streamers Range and General Features Streaming
CFP-702 Power supply unit for IP Streamers
Power supply unit for IP Streamers Universal mains power supply unit to suit the Ikusi Multicast streamers for IP broadband networks. Feeds up to eight streamer modules. Can be operated in redundancy mode
How To Connect A Tv Box To A Tv Set Top Box With A Tv Antenna From Ikusi
ITOT (MAX) :700 ma ADVANCE CE Digital Satellite TV reception, standard DVB-S. Process of De-Encryption and Digital to Analogue Transmodulation (QPSK AM). The controlled access TV stations transmitted in
AMPLIFICADORES PARA MÁSTIL Y ALIMENTADORES AMPLIFIERS FOR MAST AND POWER SUPPLIES AMPLIFICATEURS POUR MÂT ET ALIMENTATIONS SERIE 903 SERIES AMPLIFICADOR PARA MÁSTIL - AMPLIFIER FOR MAST - AMPLIFICATEUR
DTVRR5. Twin satellite receiver module for DTVRack
Twin satellite receiver module for DTVRack This manual is also applicable for DTVRR5 modules in the compact headends, TRM3x2, TRM3x2CI and TRM6x4 etc... PROGRAMMING AND INSTALLATION GUIDE V1.0 A1 C6 Ethernet
BNS-200 IPTV Streamer Dual AV to IP multicast
BNS-200 IPTV Streamer Dual AV to IP multicast ulticast streamer for IP broadband networks. Two channels of composite video with stereo audio encoded for IP streaming over IP multicast networks. Designed
Link Link sys E3000 sys RE1000
User Guide High Performance Extender Wireless-N Router Linksys Linksys RE1000 E3000Wireless-N Table of Contents Contents Chapter 1: Product Overview 1 Front 1 Top 1 Bottom 1 Back 2 Chapter 2: Advanced
Linksys WAP300N. User Guide
User Guide Contents Contents Overview Package contents 1 Back view 1 Bottom view 2 How to expand your home network 3 What is a network? 3 How to expand your home network 3 Where to find more help 3 Operating
SMATV. Ref. 236801. FibreIRS ODU32
Fibre IRS ODU 3 FibreIRS ODU3 Fibre Integrated Reception System Optical Transmitter Made in SAT +V Especificaciones técnicas SATÉLITE Technical specifications SATELLITE Frecuencia de entrada Frequency
DAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
Install DIGITAL TO TV and view what you want when you want. PROMAX in Internet: www.promaxelectronics.com
Install DIGITAL TO TV and view what you want when you want Turns satellite channels into IPTV, preserving its original digital quality Turns the video output from receivers, DVDs, cameras... into IPTV
HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator
HTT 101 HDMI/YPbPr/S-Video/AV to DVB-T HDMI/YPbPr/S DVB Encoder Modulator TABLE OF CONTENTS 1. SPECIFICATIONS... 3 1.1 Product Overview... 3 1.2 Appearance and Description... 3 1.3 System Diagram... 4
User manual for web interface MAC REF. 4449. AV-COFDM standalone modulator
User manual for web interface MAC 401 REF. 4449 AV-COFDM standalone modulator Contents 4 Introduction 4 About this Manual 4 Product Description 5 Connection to the web interface 5 Ethernet connection
NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2
NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
Instructions for - Installation of Satellite Channels
ENGLISH Instructions for - Installation of Satellite Channels Updated: March 2011 Experience Reality AQUOS LCD-TVs Spring/Summer 2011 Page - 1 - LE820 - LE822 - LE814 - LE824 - LE914 - LE925 Contents:
Link Gate SIP. (Firmware version 1.20)
Link Gate SIP (Firmware version 1.20) User guide v1.0 1 Content 2 1. Technical parameters - Dimensions 133 x 233 x 60 mm - Weight 850 g - Operating position various - Operating condition temperature: +5
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Wireless-N Gigabit Router WNR3500. You can access these features by selecting the items
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
EQUIPO DE PROCESADORES DE FI IF PROCESSING UNITS EQUIPEMENT DE TRANSPOSITION BIS SERIE 912 SERIES PROCESADOR DE FI - IF PROCESSOR - TRANSPOSITION BIS CÓDIGO-CODE-CODE MODELO-MODEL-MODELE 9120103 UC-221
MyM 3T. User Manual. English
User Manual Compact unit with 2 DVB-T tuners MPEG-2 and MPEG-4 compliant 3 analogue modulators Two CI for decryption or multidecryption NICAM or A2 stereo 12-volt power supply Low power consumption MyM
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under
IPTV Headend. IP streaming
IPTV Headend IP streaming The IPTV technology enables to distribute and manage satellite, terrestrial and Audio Video signals in buildings through Ethernet cables (LAN). IPTV Headend We provide a wide
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
How To Check If Your Router Is Working Properly
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Dual Band Wireless-N Router WNDR3300. You can access these features by selecting the
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice
Phone Adapter with 2 Ports for Voice-over-IP Voice Installation and Troubleshooting Guide Model No. PAP2 Ver. 2 Copyright and Trademarks Specifications are subject to change without notice. Linksys is
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking
Chapter 7 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax NEXT Wireless Router WNR854T. These features can be found by clicking on the Maintenance
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS
CPEi 800/825 Series. User Manual. * Please see the Introduction Section
CPEi 800/825 Series User Manual * Please see the Introduction Section Contents Introduction...iii Chapter 1: CPEi 800/825 User Guide Overview... 1-1 Powerful Features in a Single Unit... 1-2 Front of the
Cable TV Headend Solutions
Product Family DVX Platform Cable TV Headend Solutions The DVX platform TELESTE DVX is a complete solution for digital and analogue broadcasting infrastructures for cable operators. The offering includes
Technicolor ATSC-8. User s Guide. 2012 Technicolor. All Rights reserved
Technicolor ATSC-8 User s Guide 2012 Technicolor. All Rights reserved Introduction This document describes the process and procedures for integrating the ATSC-8 product with the COM1000 digital head-end
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
BlueGate SIP. VoIP GSM Gate. Quick Installation guide v 1.0
ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.cz BlueGate SIP VoIP GSM Gate Quick Installation guide v 1.0 Technical parametres Dimensions Weight Operating
HIGH PERFORMANCE WIRELESS ADAPTER
Product User Guide 4x4 MIMO Wi-Fi 802.11n 5G High performance wireless adapter HIGH PERFORMANCE WIRELESS ADAPTER 1 Table of Content 1. PRODUCT OVERVIEW... 6 1.1 Introduction... 6 1.2 Application... 6 1.3
FWS WiTDM Series KWA-O8800-I User Manual
FWS WiTDM Series KWA-O8800-I User Manual Date: 2009 / 04 / 23 Version: 1.0 1 Copyright This user s manual and the software described in it are copyrighted with all rights reserved. No part of this publication
User guide. QAM module - 492055/492056 891076C. TRIAX - your ultimate connection. Rev. 01-2012 - C. TRIAX - your ultimate connection
User guide 891076C GB QAM module - 492055/492056 TRIAX - your ultimate connection TRIAX - your ultimate connection Contents Contents Disposal... 3 Box content... 3 QAM module... 3 Labels... 4 Module installation...
Broadband Phone Gateway BPG510 Technical Users Guide
Broadband Phone Gateway BPG510 Technical Users Guide (Firmware version 0.14.1 and later) Revision 1.0 2006, 8x8 Inc. Table of Contents About your Broadband Phone Gateway (BPG510)... 4 Opening the BPG510's
Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220
Installation Guide Wireless N Access Point EAP110/EAP120/EAP220 CONTENTS Network Topology 01 Hardware Overview 02 Hardware Installation 05 1. Installation Requirements... 05 2. Mounting Bracket... 05
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
A Division of Cisco Systems, Inc. GHz 2.4 802.11g. Wireless-G. Access Point with SRX. User Guide WIRELESS WAP54GX. Model No.
A Division of Cisco Systems, Inc. GHz 2.4 802.11g WIRELESS Wireless-G Access Point with SRX User Guide Model No. WAP54GX Copyright and Trademarks Specifications are subject to change without notice. Linksys
UIP1868P User Interface Guide
UIP1868P User Interface Guide (Firmware version 0.13.4 and later) V1.1 Monday, July 8, 2005 Table of Contents Opening the UIP1868P's Configuration Utility... 3 Connecting to Your Broadband Modem... 4 Setting
(2012 10 24) manual_tocomsat duo LITE.indd 20-1 2012-10-24 7:44:57
(2012 10 24) manual_tocomsat duo LITE.indd 20-1 2012-10-24 7:44:57 TABLE OF CONTENTS Table of Contents Table of Contents Safety Warning General Information Package Contents & Features Front Panel Rear
Cisco D9854-I Advanced Program Receiver
Data Sheet Cisco D9854-I Advanced Program Receiver Product Overview The Cisco D9854-I Advanced Program Receiver (Figure 1) is designed for satellite and terrestrial content distribution applications requiring
DSL-2600U. User Manual V 1.0
DSL-2600U User Manual V 1.0 CONTENTS 1. OVERVIEW...3 1.1 ABOUT ADSL...3 1.2 ABOUT ADSL2/2+...3 1.3 FEATURES...3 2 SPECIFICATION...4 2.1 INDICATOR AND INTERFACE...4 2.2 HARDWARE CONNECTION...4 2.3 LED STATUS
your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Configuring Installing
your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Installing Configuring Contents 1 Introduction...................................................... 1 Features...........................................................
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
Signal-400 HDMI COFDM (DVB-T) Encoder & Modulator. --- Home Use
Signal-400 HDMI COFDM (DVB-T) Encoder & --- Home Use User Manual Thank you for buying this encoder modulator. Please read this manual carefully to install, use and maintain the encoder modulator in the
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
CLASS D POWER AMPLIFIERS
2015 CLASS D POWER AMPLIFIERS ETAPAS DE POTENCIA/ POWER AMPLIFIERS CLASS D 3rd. GENERATION / DSP MUSICSON ha desarrollado una gama completa de etapas de potencia de clase D de tercera generación con fuente
ADSL MODEM. User Manual V1.0
ADSL MODEM User Manual V1.0 CONTENTS 1.OVERVIEW... 3 1.1 ABOUT ADSL... 3 1.2 ABOUT ADSL2/2+... 3 1.3 FEATURES... 3 2 SPECIFICATION... 4 2.1 INTERFACE INTRODUCTION... 4 2.1.1 INDICATOR AND INTERFACE...
Installation and setup guide V 1.0
V o I P G S M G A T E BlueGate SIP 1 Installation and setup guide V 1.0 1. General description 1.1 Technical parametres Dimensions 100 x 130 x 37 mm Weight 850 g Operating position various Operating condition
Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business
Quick Start Guide Cisco Small Business WRV210 Wireless-G VPN Router with RangeBooster Package Contents WRV210 Router Ethernet Cable Power Adapter Product CD-ROM Quick Start Guide Welcome Thank you for
BlackHawk for MAC Software User Guide
BlackHawk for MAC Software User Guide Products: BLK-DH2 Series and BLK-HD Series DVRs Please read this manual before using your software, and always follow the instructions for safety and proper use. Save
Contents. User guide. TDX Headend Unit - Art. No. 492090 891072I
Contents User guide TDX Headend Unit - Art. No. 492090 891072I 1 EN Contents Contents SAFETY PRECAUTIONS... 4 Environment... 4 Power supply... 4 Weight... 4 Earth... 4 Disposal... 4 INTRODUCTION... 5 BOX
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
NMS300 Network Management System
NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
ECB1220R. Wireless SOHO Router/Client Bridge
Wireless SOHO Router/Client Bridge 2.4GH 802.11 b/g 54Mbps PRODUCT DESCRIPTION ECB-1220R is a 2.4GHz 802.11b/g broadband Wi-Fi Router with advanced AP/Client Bridge/Repeater functions. So you could implement
9600 IP. Set Top Box. User s Guide
9600 IP Set Top Box User s Guide For your safety Information contained in this manual is subject to change without notice. No part of this publication may be copied, reproduced, or translated to another
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
The new standard for customer entertainment
The new standard for customer entertainment TDH 800 basic headend system your ultimate connection 2 TRIAX TDH 800 New standard for basic headend systems The TDH 800 is a basic headend system designed to
Quick Installation Guide DAP-1360. Wireless N 300 Access Point & Router
DAP-1360 Wireless N 300 Access Point & Router BEFORE YOU BEGIN Delivery Package Access point DAP-1360 Power adapter DC 12V Ethernet cable (CAT 5E) (brochure). If any of the items are missing, please contact
Getting Started KX-TDA5480
4-Channel VoIP Gateway Card Getting Started KX-TDA5480 Model KX-TDA0484 Thank you for purchasing the Panasonic 4-Channel VoIP Gateway Card, KX-TDA5480/KX-TDA0484. Please read this manual carefully before
DECT Gigaset N510 IP PRO
DECT Gigaset N510 IP PRO SUMMARY Summary... 1 1. System Features of the DECT Gigaset N510 IP Pro... 2 Base Station Gigaset N510 IP Pro... 2 Environmental Requirements... 3 The base should be placed in
Voice Over Internet Protocol (VoIP) Configuration
(VoIP) Configuration ENGINEERING REPORT No: 02-003 Introduction This report describes interfacing the IPCS VoIP Gateway Model EGW-902 to an ESTeem Model 192E Wireless Ethernet radio modem in a demonstration
Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)
Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2) Software Version 1.9. 2902 To check that you have the latest version, go to the DOWNLOADS section of our Web
EAP9550 11N Wall Mount Access Point / WDS AP / Universal Repeater
EAP9550 is a powerful and multi-functioned 11n Access Point and it can act three modes AP/WDS/Universal Repeater. Smoke detector appearance will minimize visibility. So this model can work properly at
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
DVBLink TVSource. Installation and configuration manual
DVBLink TVSource Installation and configuration manual DVBLogic 2010 Table of contents Table of contents... 2 Introduction... 4 Installation types... 4 DVBLink TVSource local installation... 4 DVBLink
Gigabyte Content Management System Console User s Guide. Version: 0.1
Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
ImagineWorldClient Client Management Software. User s Manual. (Revision-2)
ImagineWorldClient Client Management Software User s Manual (Revision-2) (888) 379-2666 US Toll Free (905) 336-9665 Phone (905) 336-9662 Fax www.videotransmitters.com 1 Contents 1. CMS SOFTWARE FEATURES...4
How To Use A Ds6101Di On A Tv Or Tv With A Video Camera On A Network (Tivv) Or Tv (Dv) On A Computer Or Tv At A Network Or Tv On A Cell Phone Or Tv For
DS-6101DI Series Decoder Server Technical Manual Notices The information in this documentation is subject to change without notice and does not represent any commitment on behalf of HIKVISION. HIKVISION
LifeSize Networker Installation Guide
LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure
Chapter 3 Management. Remote Management
Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described
500M Powerline Pass-Through Ethernet Bridge
500M Powerline Pass-Through Ethernet Bridge Key Features IEEE Compliant HomePlug AV & LA Designed for high-definition multimedia streaming Data rate up to 500Mbps and distance up to 300 Meters over existing
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
EPI-3601S Wireless LAN PCI adapter Version 1.2 EPI-3601S. Wireless LAN PCI Adapter. (802.11g & 802.11b up to 108 Mbps) User Manual. Version: 1.
EPI-3601S Wireless LAN PCI Adapter (802.11g & 802.11b up to 108 Mbps) User Manual Version: 1.2 1 TABLE OF CONTENTS 1 INTRODUCTION...3 2 FEATURES...3 3 PACKAGE CONTENTS...4 4 SYSTEM REQUIREMENTS...5 5 INSTALLATION...5
Chapter 4 Managing Your Network
Chapter 4 Managing Your Network This chapter describes how to perform network management tasks with your ADSL2+ Modem Wireless Router. Backing Up, Restoring, or Erasing Your Settings The configuration
Wifi Pan/Tilt IP Camera User Manual
Wifi Pan/Tilt IP Camera User Manual Rev. 3.0 Software Version 3.00 May. 25 th.2009 Table of Contents 1. PRODUCT VIEWS...3 1.1. PRONT PANEL...3 1.2. BACK PANEL...3 1.3. ACCESSORIES...4 2. SETUP AND STARTUP...5
MN-700 Base Station Configuration Guide
MN-700 Base Station Configuration Guide Contents pen the Base Station Management Tool...3 Log ff the Base Station Management Tool...3 Navigate the Base Station Management Tool...4 Current Base Station
Quick Start Guide NVR DS-7104NI-SL/W NVR. www.hikvision.com. First Choice For Security Professionals
Quick Start Guide NVR DS-7104NI-SL/W NVR NOTE: For more detailed information, refer to the User s Manual on the CD-ROM. You must use your PC or MAC to access the files. www.hikvision.com Quick Start 1.
User s Manual of DVR DVS Remote Client Software V 4.0.1
User s Manual of DVR DVS Remote Client Software V 4.0.1 Index Version description...4 1 Introduction...8 2 Software Install, Uninstall and use...9 2.1 Install remote client software ver4.0.1...9 2.2 Uninstall
Note: these functions are available if service provider supports them.
Key Feature New Feature Remote Maintenance: phone can be diagnosed and configured by remote. Zero Config: automated provisioning and software upgrading even through firewall/nat. Centralized Management:
Wireless LAN Access Point. IEEE 802.11g 54Mbps. User s Manual
Wireless LAN Access Point IEEE 802.11g 54Mbps User s Manual Table of Contents Chapter 1 Introduction... 1 1.1 Package Contents...2 1.2 Features...2 1.3 Specifications...2 1.4 Physical Description...3 Chapter
External Storage 200 Series. User s Manual
External Storage 200 Series User s Manual Version 1.2 00P3DS200ZSEA2 Table of Contents User s Manual 1. Overview...3 2. Key Features...3 3. Rear Connectors...4 4. Setup the External Storage 200...4 5.
A Division of Cisco Systems, Inc. GHz 2.4 802.11g. Wireless-G. USB Network Adapter with RangeBooster. User Guide WIRELESS WUSB54GR. Model No.
A Division of Cisco Systems, Inc. GHz 2.4 802.11g WIRELESS Wireless-G USB Network Adapter with RangeBooster User Guide Model No. WUSB54GR Copyright and Trademarks Specifications are subject to change without