Energy Efficiency Strategies for Municipal Wastewater Treatment Facilities
|
|
|
- Julie Flowers
- 10 years ago
- Views:
Transcription
1 Energy Efficiency Strategies for Municipal Wastewater Treatment Facilities J. Daw and K. Hallett National Renewable Energy Laboratory J. DeWolfe and I. Venner Malcolm Pirnie, the Water Division of ARCADIS NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Technical Report NREL/TP-7A January 2012 Contract No. DE-AC36-08GO28308
2 Energy Efficiency Strategies for Municipal Wastewater Treatment Facilities J. Daw and K. Hallett National Renewable Energy Laboratory J. DeWolfe and I. Venner Malcolm Pirnie, the Water Division of ARCADIS Prepared under Task No. IGST.1104 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado Technical Report NREL/TP-7A January 2012 Contract No. DE-AC36-08GO28308
3 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. Available electronically at Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S. Department of Energy Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN phone: fax: mailto:[email protected] Available for sale to the public, in paper, from: U.S. Department of Commerce National Technical Information Service 5285 Port Royal Road Springfield, VA phone: fax: [email protected] online ordering: Cover Photos: (left to right) PIX 16416, PIX 17423, PIX 16560, PIX 17613, PIX 17436, PIX Printed on paper containing at least 50% wastepaper, including 10% post consumer waste.
4 Contacts National Renewable Energy Laboratory Jennifer Daw, PE, CEM, LEED AP Sustainability Project Manager 1617 Cole Boulevard Golden, CO Phone: Kathleen Hallett Energy Information Analyst 1617 Cole Boulevard Golden, CO Phone: Malcolm Pirnie, the Water Division of ARCADIS James DeWolfe, PE, BCEE, CWO Principal Environmental Engineer 1951 Pine Hall Road, Suite 125 State College, PA Phone: Ifetayo Venner, PE Senior Environmental Engineer Riveredge Drive, Suite 600 Tampa, FL Phone: iii
5 Acknowledgements The National Renewable Energy Laboratory (NREL) would like to acknowledge the contributions of the U.S. Department of Energy s Technical Assistance Program, the Office of Resource Efficiency, the town of Crested Butte, and Mt. Crested Butte Water and Sanitation District in the funding of this effort and Malcolm Pirnie, the Water Division of ARCADIS and Gunnison County Electric Association for their expertise in performing the energy audit. iv
6 List of Acronyms and Abbreviations ASHRAE ATAD BOD DO EPA GCEA HP I&I MGD NREL O&M OpenEI SCADA TSS UV VFD WWTP American Society for Heating, Refrigerating and Air-Conditioning Engineers Autothermal Thermophilic Aerobic Digestion Biological Oxygen Demand dissolved oxygen U.S. Environmental Protection Agency Gunnison County Electric Association horsepower infiltration and inflow million gallons per day National Renewable Energy Laboratory operations and maintenance Open Energy Information Initiative supervisory control and data acquisition Total Suspended Solids ultraviolet Variable Frequency Drive wastewater treatment plant v
7 Executive Summary Water and wastewater systems are significant energy consumers with an estimated 3%-4% of total U.S. electricity consumption used for the movement and treatment of water and wastewater [1,2]. Water-energy issues are of growing importance in the context of water shortages, higher energy and material costs, and a changing climate. In this economic environment, it is in the best interest for utilities to find efficiencies, both in water and energy use. Performing energy audits at water and wastewater treatment facilities is one way community energy managers can identify opportunities to save money, energy, and water. In this paper the importance of energy use in wastewater facilities is illustrated by a case study of a process energy audit performed for Crested Butte, Colorado s wastewater treatment plant 1. The energy audit identified opportunities for significant energy savings by looking at power intensive unit processes such as influent pumping, aeration, ultraviolet disinfection, and solids handling. This case study presents best practices that can be readily adopted by facility managers in their pursuit of energy and financial savings in water and wastewater treatment. This paper is intended to improve community energy managers understanding of the role that the water and wastewater sector plays in a community s total energy consumption. The energy efficiency strategies described provide information on energy savings opportunities, which can be used as a basis for discussing energy management goals with water and wastewater treatment facility managers. 1 Wastewater Division of the Public Works Department: vi
8 Table of Contents 1 Introduction... 1 Energy Use in the Water and Wastewater Sector...1 EPA Region 8 Partnership Case Study: Crested Butte... 2 Background...2 Crested Butte s WWTP...3 Energy Audit...3 Collecting Data...4 Existing Process Performance...5 Influent Pumping/Headworks...5 Aeration/Oxidation Ditch...6 Clarification...6 Ultraviolet Disinfection...6 Solids Handling...6 Plant Walkthrough...6 Primary Opportunities for Energy Savings...8 Influent Pumping/Headworks...8 Aeration/Oxidation Ditch...8 Ultraviolet Disinfection...9 Solids Handling...9 Reducing Influent Flow...10 Community Support...10 Next Steps for Crested Butte Strategies To Consider Process Energy...11 Operational Controls...12 Repair and Replacement...12 Biosolids...12 Infiltration, Inflow and Leaks...13 On-Site Renewable Energy...13 Conservation Resources Conclusion References vii
9 List of Figures Figure 1. Crested Butte, Colorado... 2 Figure 2. Crested Butte WWTP process flow diagram... 3 Figure 3. Energy audit levels... 4 Figure 4. Collecting UV system power draw data... 7 Figure 5. Measuring DO profile... 7 Figure 6. Mechanical aerator in oxidation ditch... 9 Figure 7. Typical WWTP energy consumers Figure 8 Quality versus energy List of Tables Table 1. Crested Butte WWTP: Major Energy Consumers... 5 Table 2. Energy Savings Recommendations Table 3. Energy Efficiency Strategies for Municipal WWTPs viii
10 1 Introduction Energy Use in the Water and Wastewater Sector Water and wastewater systems are significant energy consumers. An estimated 3%-4% of U.S. electricity consumption is used for the movement and treatment of water and wastewater [1,2]. The exact cost of energy use can vary widely from one utility to the next, with estimates ranging from 2% 60% of total operating costs [3,4]. Energy represents a substantial cost to wastewater utilities, as it is typically required for all stages in the treatment process, from the collection of raw sewage to the discharge of treated effluent. Given that water and wastewater treatment plants are not primarily designed and operated with energy efficiency as a chief concern, these systems can be overlooked when communities fund energy improvement projects. However, substantial energy and financial savings can be uncovered through operational changes and capital improvements at water and wastewater utilities. Operators and managers of water and wastewater facilities have a wide range of priorities, of which energy consumption is just one [5]. Some of their primary duties include: Complying with regulatory requirements to meet customer, public health, and ecological demands Providing reliable service at reasonable and predictable rates Balancing repair and replacement needs with long-term debt, equipment condition, ongoing operations and maintenance costs, and revenue Optimizing operations and maintenance to reduce costs and ensure longevity of assets. Allocating time to conduct an energy audit and make the necessary physical and operational changes can produce substantial benefits. Energy audits help identify the greatest energyconsumers at a facility, reveal opportunities for operational improvements, and detect issues with aging and underperforming equipment. The results of an audit can help to improve energy efficiency, which represents an opportunity for municipalities to reduce operating costs as well as impacts on both the environment and the surrounding community. EPA Region 8 Partnership The U.S. Environmental Protection Agency (EPA) Region 8 office serves the Intermountain West: Colorado, Montana, North Dakota, South Dakota, Utah and Wyoming. In October 2010, EPA Region 8 initiated the EPA Region 8 Utilities Partnership Energy Management Initiative for Public Wastewater and Drinking Water Utilities program with a focus on helping municipal water and wastewater utilities reduce energy consumption, improve reliability and performance, and minimize environmental impacts. In this program, the Region 8 office partnered with community water and wastewater facilities to complete the following tasks: Benchmark current and future energy use in the EPA Portfolio Manager tool [6] Perform process energy audits 1
11 Develop an Energy Management Plan using EPA s Ensuring a Sustainable Future: An Energy Management Guidebook for Wastewater and Water Utilities 2 Commit to implementing energy efficiency improvements and sharing results with the EPA Region 8. To increase the breadth of this program and provide value to municipalities that did not participate, EPA Region 8 plans to create a set of case studies to share with other water and wastewater utilities across the Intermountain West that profile some of the participating utilities and illustrate the process, benefits and challenges of optimizing energy performance. Figure 1. Crested Butte, Colorado Source: NREL/PIX Case Study: Crested Butte Background In support of their participation in the program, the town of Crested Butte was required to perform a process energy audit of its wastewater treatment plant (WWTP). The energy audit focused on readily implementable opportunities for energy reduction through process modification and operational improvements. The audit considered optimization of existing processes to realize improved control, monitoring, and WWTP effluent quality. The audit also helped the town begin tracking and benchmarking its WWTP energy use. The Department of Energy s National Renewable Energy Laboratory (NREL) partnered with the town of Crested Butte, Malcolm Pirnie, the Water Division of ARCADIS, the Office of Resource Efficiency, and Gunnison County Electric Association (GCEA) (who served as the assessment team) in performing the energy audit. This partnership created an opportunity for these organizations to support local capacity development, working to educate communities and water/wastewater utilities on how to analyze and achieve energy efficiency savings. The intent of this paper is to share energy efficiency strategies learned from the Crested Butte process energy audit with other communities in order to help them achieve their energy reduction and environmental goals
12 Crested Butte s WWTP Crested Butte is a small town located on the Western Slope of Colorado and is a major tourist destination for outdoor sports. The WWTP, constructed in 1997, serves the town, which has a permanent population of 1,500 people. The WWTP treats wastewater from residential and commercial customers, with no major industrial discharges to the plant. The plant also accepts solids from the Mt. Crested Butte Water and Sanitation District. The town has an oxidation ditch WWTP, with a permitted capacity of 0.6 million gallons per day (MGD) for a 30-day average daily flow. The plant consists of grit removal, influent pumping, aeration, clarification, ultraviolet (UV) disinfection, and solids handling processes. Treated effluent from the plant discharges to the Slate River. Sludge is thickened and dewatered on-site and hauled to a local landfill for disposal. A simplified process flow diagram for the plant is shown in Figure 2. Figure 2. Crested Butte WWTP process flow diagram Source: NREL Energy Audit As part of the town s participation in the EPA program, an energy audit of the treatment process was required. While not included in this study, building energy audits, which evaluate lighting, heating, cooling, and ventilation systems, can also yield substantial financial and energy savings in treatment facilities. There are three levels of energy audits outlined by the American Society for Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). These audit levels differ with respect to level of complexity, depth of analyses, and the degree of detail the audit can provide. Audits range from Level 1 (a walkthrough) to Level 3 (computer modeling). 3
13 Energy Audit Levels [7] Level 1: Walkthrough assessment Level 2: Energy survey & analysis Level 3: Detailed analysis/ modeling Figure 3. Energy audit levels Source: NREL For Crested Butte, a Level 1 audit was performed, which included a plant walkthrough focused on treatment process energy use. The Level 1 audit: Evaluates energy consumption and efficiency through an on-site survey to identify maintenance and/or operational needs and deficient equipment Uses energy consumption information to understand usage patterns and to develop an energy baseline Estimates energy and cost savings with an emphasis on low or no-cost measures. Collecting Data The process energy audit was initiated by compiling data from drawings, operational records, utility bills, and equipment inventories to develop an understanding of plant energy usage patterns. The assessment team consulted drawings to look for any operational or energy issues that could be associated with the physical layout of the plant. For example, the drawings showed that the existing dissolved oxygen (DO) meter was located in the anoxic zone of the oxidation ditch. This configuration does not establish an ideal feedback for oxygen control or oxidation ditch performance. It is typically more effective to locate this measurement device where DO levels are greater than zero, such as near the effluent of the ditch. Operational records and parameters such as Biological Oxygen Demand (BOD) and Total Suspended Solids (TSS) were used to distinguish patterns in raw water quality and WWTP performance. Plant operational data were used to establish three operating seasons with distinct raw water conditions. These seasons reflect changes in temporary population and infiltration experienced in the collection system throughout the year. The conditions associated with the three seasons are summarized below: Season 1 (October March): Low flow, low load (BOD, TSS on a pound per day basis), and low wastewater temperature Season 2 (April June): High flow, average load, and low wastewater temperature Season 3 (July September): Average flow, high load, and higher wastewater temperature. 4
14 The assessment team reviewed equipment inventories to determine the age and horsepower of plant equipment and to identify major energy consumers within the facility. An abbreviated list of major energy consumers in the town s WWTP, along with their typical operations and controls, are summarized in Table 1. This information was used to focus audit efforts on major energy consuming processes within the plant to maximize energy savings opportunities. Table 1. Crested Butte WWTP: Major Energy Consumers Equipment Quantity Horsepower Operations Controls Mechanical Aerator 1 75 Continuous Variable Frequency Drive (VFD), manual adjustment Centrifuge hrs/week VFD, fixed speed Influent Pump (No. 1) Continuous VFD, speed based on flow Influent Pumps (No. 2 & 3) Pump No. 2 continuous Pump No. 3 backup VFD, speed based on flow VFD, speed based on flow Blowers 3 15 Intermittent Fixed speed Mixers 3 4 Continuous Fixed speed UV System 2 banks 7.3 (kw) Continuous Fixed, 2 banks Existing Process Performance Each process was discussed in detail with plant operations staff to understand performance trends and concerns. General observations on the WWTP s process performance and operational strategies are described in the following paragraphs. Influent Pumping/Headworks The influent system consists of three pumps: one 4.7 horsepower (HP) pump (Pump No. 1) two 17.5 HP pumps (Pumps No. 2 and No. 3). Pump No. 2 runs continuously based on level detection in the wet well. All pumps have Variable Frequency Drives (VFDs). 5
15 Aeration/Oxidation Ditch The town s WWTP has one oxidation ditch that provides aerobic removal of BOD and ammonia. There is an anoxic portion of the ditch that provides denitrification, recovers alkalinity, and reduces oxygen demand. The ditch has one 75 HP aerator running on a VFD that is operated based on manual adjustment from a daily DO concentration reading. Typically, energy savings from VFDs come from adjustments that are made automatically to adapt to system conditions, not manual adjustments. The ditch also has two continuously operated mixers in the anoxic zone. The existing DO meter located in the anoxic zone is not operational. Clarification The WWTP has two clarifiers, one that operates continuously and a supplemental clarifier for high flow events. Ultraviolet Disinfection The UV system was designed for a plant flow rate of 1.3 MGD (double the permitted capacity of the facility). The system currently operates with both banks on-line. Plant staff change UV system lamps once a year for preventative maintenance. Since 2008, the average effluent fecal coliform concentration has been 8.3 counts/100 milliliters (ml) with a 7-day average of counts/100 ml. The permitted effluent Escherichia Coli (a part of the group fecal coliform) concentration is 1372 counts/100 ml (30-day average) and 2,744 counts/100 ml (7-day average). The current operational approach results in effluent fecal coliform levels that are significantly below permit requirements. Solids Handling The WWTP has an Autothermal Thermophilic Aerobic Digestion (ATAD) system, which is not operational due to odor problems. Therefore, sludge is currently thickened in the raw sludge storage tank and transferred to the thickened sludge storage tank for holding. Due to existing plant piping configurations, sludge must be pumped from the thickened sludge storage tank to the ATAD holding tank to reach the centrifuge for dewatering. Although this allows for additional storage, and therefore potentially less frequent trips to the landfill, it also requires that the 15 HP blower associated with the ATAD storage tank remain operational. The 40 HP centrifuge is controlled by VFD, but typically runs at a constant speed. The centrifuge fills a 20 cubic yard dumpster once a week. Centrate from the centrifuge is piped to the oxidation ditch, which may affect performance of the oxidation process. Plant Walkthrough Using this operational insight, the assessment team visited the WWTP to perform a Level 1 plant walkthrough. This effort consisted of visual inspections to identify operational or maintenance issues and the collection of energy data from major plant equipment. These data will be used by the town to develop estimated cost savings associated with operations and maintenance (O&M) and to prioritize capital improvements to the facility. GCEA assisted the assessment team during the audit by measuring actual power draw for major equipment, including sludge transfer pumps and blowers, which were rotated into operation for 15-minute increments to record actual power use. Using a consistent time interval to measure 6
16 power draw allows sufficient time for power consumption associated with equipment start-up to level out. These data will be considered by the town to help make prioritizations for improvement. Figure 4. Collecting UV system power draw data Source: NREL/PIX During the audit, DO concentrations were measured in the oxidation ditch to determine aeration effectiveness. These concentrations created a DO profile that was used to better understand plant operations. Figure 5. Measuring DO profile Source: NREL/PIX
17 A BioWin model 3 was developed for the plant using influent characteristics, temperature, historical DO concentrations, typical aerator speeds, and the measured DO profile. Using this process model, the assessment team determined that the existing aerator, which is approximately 15 years old, had poor transfer efficiency relative to newer aerators meaning more energy is used to drive the aerator than would be expected for the resulting DO levels. Primary Opportunities for Energy Savings Based on plant operational information and data collected during the audit, the assessment team developed energy savings recommendations for the WWTP. Influent Pumping/Headworks Flow data provided for the WWTP indicates that infiltration and inflow (I&I) is problematic during Season 2 (April June). To mitigate these issues, it is helpful to identify critical I&I areas in the collection system caused by leaks and breaks. This information will help to prioritize efforts to repair or replace system piping. Another best practice for Crested Butte s WWTP is to tailor the operational strategy for the headworks to meet the three distinct seasons mentioned above. Using smaller horsepower equipment, such as Pump No. 1, to the extent possible, can reduce ongoing energy consumption. Based on typical daily flow patterns, Pump No. 1 could address nightly and mid-day low flow periods in Season 1 (October March) and nightly low flow periods in Season 3 (July September). As Pump No. 1 ages, the town may consider replacing it with a slightly higher capacity pump controlled by VFD to address wet well fluctuations. This increased capacity and improved controls would extend the pump s operations during lower flow periods and minimize usage of the higher horsepower pumps. Aeration/Oxidation Ditch The DO levels measured in the oxidation ditch, in concert with other operational data, indicated that the aerator was not performing efficiently. Given that this is the largest horsepower motor at the WWTP, and that the aerator is nearing the end of its useful life, the assessment team recommends replacing it with a more energy-efficient model. The WWTP may also consider installing a new DO meter and/or ammonia sensor near the ditch outfall to provide more useful feedback on ditch performance. Connecting this meter to the plant supervisory control and data acquisition (SCADA) system will allow for continuous monitoring and control of DO levels. Additional energy savings can be achieved if these DO readings are used to automatically control the speed of the aerator. As a best practice, the mixers are recommended to only be used when the aerator is not operating, which will further reduce the energy use of this process. 3 BioWin is a Microsoft Windows-based simulator used in the analysis and design of wastewater treatment plants. 8
18 Figure 6. Mechanical aerator in oxidation ditch Source: NREL/PIX Ultraviolet Disinfection Current operations of the UV system are consistent with the ultimate design flow rate, 1.3 MGD. With a current maximum operating flow rate of 0.6 MGD (less than half of the design flow rate of the UV system), the WWTP is surpassing permit requirements. Accordingly, the assessment team recommends that the WWTP operate only one bank of the UV system instead of both banks. Since the system was designed to treat significantly more wastewater than the WWTP currently receives, the facility could also work with the manufacturer to potentially modify the system to save energy by removing bulbs and retrofitting or de-energizing some of the ballasts. Connecting the UV system to SCADA would also improve control of performance. The WWTP may also consider replacing UV system lamps less frequently the manufacturer recommends that bulbs be replaced after 13,500 hours of operation or every 1.5 years. Current operational practices are to replace bulbs as part of scheduled annual maintenance, regardless of running hours. Increasing the bulb replacement interval will save material costs and waste associated with operation of the plant. Solids Handling The current solids handling process is operating inefficiently due to the use of existing ATAD system piping to reach the centrifuge for dewatering. When the ATAD system becomes operational again, this inefficiency will improve. However, the WWTP may also consider making piping retrofits to allow sludge to move directly from the thickened sludge tank to the centrifuge, bypassing the ATAD system. This change would eliminate transfer pumping within the solids handling system. One of the principal products of a WWTP is sewage sludge or biosolids [8]. Until two or three decades ago, the typical practice for WWTPs in Region 8 was to dispose of biosolids via landfill or incineration. These days, however, more facilities put biosolids to beneficial reuse and 85% of the biosolids generated in Region 8 are now recycled [9]. Most commonly, biosolids are used as a soil amendment to fertilize agricultural land or to restore soils on reclaimed land. Crested Butte s WWTP may also want to consider studying the energy requirements that are needed to treat its biosolids in order to divert them from the landfill for beneficial uses such as fertilizer for agriculture. While more energy is required to treat solids to a Class A or B standard 4, it could also reduce vehicle miles to haul the material to the landfill, alleviate some of 4 EPA Sewage Sludge (Biosolids): 9
19 the long-term environmental burden of landfill disposal, and reduce greenhouse gas emissions associated with landfilled sludge. Reducing Influent Flow Pinpointing areas in the collection system with I&I problems can help the WWTP to focus repair and replacement efforts. Infiltration of groundwater can be a major contributor to the WWTP influent flow. Regular cleaning, inspection, and slip lining of collection system piping can greatly mitigate infiltration and reduce the quantity of wastewater being treated. Community Support An active community-wide conservation program is another essential factor in reducing WWTP plant inflow. Working with the community to promote conservation awareness and to take actions such as installing water efficient fixtures, can significantly reduce flows at the WWTP and save energy. Recommendations and estimated energy and annual financial savings are shown in Table 2. These recommendations have been divided into short-term opportunities, which are lower cost and more readily implementable, and long-term opportunities, which would require more planning and capital expenditure. As presented in the table below, the aeration process offers the largest opportunities for energy and financial savings for the town of Crested Butte. Table 2. Energy Savings Recommendations Process Recommendations Savings (kwh - % energy - $/year) Influent Pumping/Headworks Use Pump No.1 during low flow (ST) Conduct I&I study (LT) Replace Pump No.1 (LT) 4,300-10% - $150 14,000-35% - $550 8,700-20% - $350 Aeration/Oxidation Ditch UV Disinfection Solids Handling Turn mixers off when aerator operates (ST) Replace DO meter (ST) Connect new DO meter to SCADA/ Replace aerator (LT) Remove one UV bank from service/ Determine if bulbs can be removed (ST) Retrofit piping to feed sludge directly from thickened sludge tank to centrifuge (LT) ST = short-term, LT- long-term 45,900-90% - $1,750 19,800-10% - $ ,000-40% - $4,700 32,000-50% - $1,200 23, % - $1,000 10
20 Next Steps for Crested Butte As a next step, the town will further quantify energy savings associated with the recommended improvements and begin work on their Energy Management Plan. The Energy Management Plan will establish the objectives and targets to be used to measure the town s progress in energy reduction and will guide the town s capital improvement efforts as well as plant O&M activities. Further information on how this information will be used can be found in the EPA s Guidebook [10]. Crested Butte s WWTP will also use its energy data to benchmark operational performance against other WWTPs, with the EPA Portfolio Manager. Portfolio Manager is a tool that can help the town identify further opportunities for performance improvement and prioritize investments. 3 Strategies To Consider The Crested Butte case study is an excellent demonstration of how conducting an energy audit can improve a facility or community energy manager s understanding of energy savings opportunities at water and wastewater facilities. The following sections provide a brief overview of several general energy savings strategies. Facility and community energy managers alike may want to consider how these energy savings strategies (summarized in Table 3) could be adopted at their community s water and wastewater treatment facilities. Operators or managers who are ready to develop and implement a comprehensive energy management plan, and readers who are interested in step-by-step guidance, can get started with EPA s Ensuring a Sustainable Future: An Energy Management Guidebook for Wastewater and Water Utilities [10]. Process Energy When conducting an energy audit, focus efforts on the biggest energy consumers at the facility. This can be determined by reviewing drawings, nameplate data, or by measuring power draw of equipment. The aeration process is the largest energy consumer for most WWTPs as demonstrated by the typical WWTP energy usage patterns in Figure 7 [11]. Figure 7. Typical WWTP energy consumers Source: Malcolm Pirnie, the Water Division of ARCADIS 11
21 Operational Controls Running a WWTP is not a one size fits all operation. Regularly evaluating influent and effluent trends can help utilities to tailor operational strategies accordingly. These parameters may vary by season, time of day, and/or have other unique characteristics. System controls that use SCADA feedback and VFDs can be used to optimize effluent quality and energy consumption. This balancing act is a continuous process that facility managers must consider, knowing that higher effluent quality is often at the expense of increased energy use. Achieving an optimal balance between quality and energy is the ultimate goal. Quality Energy Figure 8. Quality versus energy Source: NREL Repair and Replacement As part of capital planning efforts, a best practice for facilities is to regularly evaluate the condition, performance and remaining useful life of process equipment. Aging equipment is more inefficient, can be costly to repair, and typically requires more energy than newer models. When doing an energy audit, equipment age and operational efficiency are major considerations. Evaluating preventative maintenance practices also helps to ensure that equipment is receiving appropriate maintenance for the level of use [12]. Biosolids There are significant environmental and financial tradeoffs between providing higher quality biosolids and the subsequent energy demands. When evaluating biosolids treatment and disposal options, the following factors are important for facilities to consider [13]: Transportation distance from the WWTP to the landfill affects cost to haul biosolids for disposal Additional costs tipping fees and additional treatment for land application may incur additional costs for biosolids Revenue WWTPs may receive payment for their biosolids as a soil amendment Carbon emissions landfilling of biosolids can result in greater emissions than land application Sustainability using biosolids reduces demand for landfills and synthetic fertilizers, and can help the reclamation and re-vegetation process for brownfield sites. 12
22 Infiltration, Inflow and Leaks The wastewater collection system is another area of opportunity for utilities. A considerable amount of energy is wasted treating groundwater that infiltrates systems through pipes that are broken or out of alignment. Similarly, breaks and leaks in the collection system increase the energy required to pump sewage to the treatment plant. Focusing efforts on identifying areas with I&I, breaks, and leaks can enable utilities to direct repair and replacement efforts to areas that will provide greater energy and financial savings. On-Site Renewable Energy A best practice for all communities is to look for opportunities to incorporate on-site renewable energy at their facilities. After energy efficiency, renewable energy is another effective way to save money by reducing energy purchases. All renewable resources available within the community, including wind, solar, water, and wastes generated on-site, may be considered as potential energy sources. These renewable systems are selected and installed to maximize energy production [14]. WWTPs with anaerobic digestion provide a unique opportunity to create on-site heat and power, by capturing biogas emissions as fuel for on-site energy generation [15]. Conservation Effective outreach within the community can yield substantial reductions in water use and wastewater generation. Programs can be implemented that incentivize community members, businesses, and/or industries to reduce their water usage. By providing low-flow fixtures at a discounted fee, conducting water audits, and/or using inverted block rate structures, utilities can substantially reduce the amount of effluent to be treated and dramatically lower energy use within the community. Creating behavioral change through public education programs is another essential element in promoting conservation. As allowed by local water rights, maximizing the use of fit for purpose or reuse water may be considered as another conservation strategy. Table 3, below, summarizes the strategies that may be adopted by municipal wastewater treatment facilities to improve energy efficiency. Table 3. Energy Efficiency Strategies for Municipal WWTPs Focus Efforts for Energy Savings Process Energy Focus on biggest energy consumers at WWTP Operational Controls Tailor operations to meet seasonal and diurnal changes Quality vs. Energy Balance water quality goals with energy needs Repair and Replacement Consider equipment life and energy usage to guide repair and replacement Biosolids Consider tradeoffs between treatment energy and improved biosolids quality Infiltration/Inflow Address I&I to reduce treatment energy Leaks and Breaks Address leaks and breaks to reduce pumping energy On-Site Renewable Energy Consider opportunities for on-site generation to reduce energy purchases Conservation Educate the community: Less water reduces WWTP loads and energy needs 13
23 4 Resources NREL provides access to hundreds of entries with helpful tools, as part of the Open Energy Information Initiative (OpenEI). OpenEI is a wiki that allows users to enter information directly into its database, in order to share resources on renewable energy and energy efficiency: NREL provides limited technical assistance through various federal programs. Under these programs, agencies may apply to receive technical assistance from NREL for understanding and deploying energy efficiency and renewable energy technologies: 5 Conclusion The Crested Butte case study demonstrates the importance of energy audits in providing community energy managers with the ability to recognize and implement energy saving opportunities at their facilities. Working to improve the understanding of energy patterns and efficiency opportunities is a best practice that all communities can adopt. By tracking energy usage, benchmarking, and making operational improvements, all communities can begin their efforts to reduce energy use and realize financial savings. 14
24 6 References 1. Electric Power Research Institute (EPRI). Water & Sustainability (Volume 4): U.S. Electricity Consumption for the Water Supply & Treatment The Next Half Century. Topical Report Palo Alto, CA: EPRI, March Galbraith, Kate. How Energy Drains Water Supplies. New York Times, September 18, Accessed September 22, Carlson, S.; Walburger, A. Energy Index Development for Benchmarking Water Utilities and Wastewater Utilities. Denver, CO: AWWA Research Foundation, Elliott, T.; Zeier, B., Xagoraraki, I.; Harrington, G. W. Energy Use at Wisconsin s Drinking Water Facilities. Report Madison, WI: Energy Center of Wisconsin, July Utility Advisory Group. Effective Utility Management: A Primer for Water and Wastewater Utilities. Utility Advisory Group, June ENERGY STAR. Portfolio Manager Overview. Accessed October 27, American Society for Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Energy Use and Management, Chapter 36 in ASHRAE Handbook - HVAC Applications. (Atlanta: 2011). 8. U.S. Environmental Protection Agency (EPA). Biosolids: Targeted National Sewage Sludge Survey Report Overview. EPA 822-R January U.S. Environmental Protection Agency (EPA). Biosolids. Accessed September 22, U.S. Environmental Protection Agency (EPA) and Global Environment and Technology Foundation. Ensuring a Sustainable Future: An Energy Management Guidebook for Wastewater and Water Utilities. January Malcolm Pirnie, the Water Division of ARCADIS (2011). Typical Energy Usage Patterns in U.S. Wastewater Treatment Plants. 12. National Asset Management Strategy Group. International Infrastructure Management Manual, Raucher, R.S.; Garver, D.; Hallett, K.; Henderson, J.; Wagner, C. An Economic Framework for Evaluating the Benefits and Costs of Biosolids Management Options. Alexandria, VA: Water Environment Research Foundation,
25 14. Federal Energy Management Program, Renewable Energy Resources and Technologies. Accessed December 2, U.S. Environmental Protection Agency (EPA). Combined Heat and Power Partnership. Accessed December 2,
Energy Audits Waste Water Treatment Plants
Energy Audits Waste Water Treatment Plants Ohio Water Environment Association Conference June 20, 2012 Presented by: Samuel J. Morgan, P.E., LEED AP CT Consultants, Inc. World Energy Trend US Total Energy
Process and Energy Audits at Water and Wastewater Facilities. Thomas Devine, CAP, CEM, LEED AP April 25 2012
Process and Energy Audits at Water and Wastewater Facilities Thomas Devine, CAP, CEM, LEED AP April 25 2012 Presentation Outline Types of Audits Benchmarking Submetering Data Collection/Information Gathering
The City of Boulder 75 th Street Wastewater Treatment Facility
The City of Boulder 75 th Street Wastewater Treatment Facility Wastewater Collection and Treatment The Foundation of Public Health Wastewater Collection Boulder s wastewater collection system, also known
NREL Job Task Analysis: Crew Leader
NREL Job Task Analysis: Crew Leader Chuck Kurnik National Renewable Energy Laboratory Cynthia Woodley Professional Testing Inc. NREL is a national laboratory of the U.S. Department of Energy, Office of
Early Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA)
Technical Report NREL/TP-56-588 January 3 Early Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA) Quarter 3 Composite Data Products Jennifer Kurtz, Keith Wipke, Sam Sprik, Todd Ramsden,
Description of the Water Conserv II Facility
Description of the Water Conserv II Facility Introduction The Water Conserv II (WCII) Water Reclamation Facility provides service to a majority of the southwest section of Orlando. The WCII facility has
Cambridge Wastewater Treatment Facility
Cambridge Wastewater Treatment Facility Emergency Situations If you have a water or sewer emergency that relates to the City s utility system call the Public Works office at 763-689-1800 on normal working
Aeration Efficiency Guide
Aeration Efficiency Guide Environmental Dynamics InTernational EDI specializes in the research, development, and application of advanced technology aeration and biological treatment solutions for municipal
City of Charlottetown Wastewater Treatment Expansion & Upgrading
City of Charlottetown Wastewater Treatment Expansion & Upgrading Background As Canada s smallest provincial capital, the City of the Charlottetown has a population of approximately 34,000 residents and
New York State Energy Research & Development Authority. Water & Wastewater Energy Management. Best Practices Handbook. March 2010
New York State Energy Research & Development Authority Water & Wastewater Energy Management s Handbook March 2010 Content Revised September 2010 Content prepared by: Malcolm Pirnie, Inc. under contract
Clean Water State Revolving Fund (CWSRF) Requirements and Guidance for a Fiscal Sustainability Plan (FSP)
Clean Water State Revolving Fund (CWSRF) Requirements and Guidance for a Fiscal Sustainability Plan (FSP) Maine CWSRF Fiscal Sustainability Plan Requirements Starting October 1, 2014, a Fiscal Sustainability
William E. Dunn Water Reclamation Facility. Facility Overview & Information
William E. Dunn Water Reclamation Facility Facility Overview & Information General Area Served: Plant History Facility Highlights Northern Pinellas County St. Joseph Sound to East Lake Road (E/W) Tampa
Pursuant to Department of Environmental Protection Rules Chapter 555, effective March 9, 2009
APPLICATION FOR ADDITION OF TRANSPORTED WASTES IN WASTEWATER TREATMENT FACILITIES Pursuant to Department of Environmental Protection Rules Chapter 555, effective March 9, 2009 This application is to be
Regional Field Verification Operational Results from Four Small Wind Turbines in the Pacific Northwest
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Regional Field Verification Operational
Asset Management Answering the 5 Core Questions
Asset Management Answering the 5 Core Questions by Timothy Taber, PE Barton & Loguidice Page 1 Drivers Asset Management Case Study 1. What is the current state of my assets? 2. What is my required sustainable
Rate Analysis of Two Photovoltaic Systems in San Diego
Rate Analysis of Two Photovoltaic Systems in San Diego Technical Report NREL/TP-6A2-43537 July 2009 Elizabeth Doris, Sean Ong, and Otto Van Geet Rate Analysis of Two Photovoltaic Systems in San Diego Technical
MUNICIPAL WASTEWATER TREATMENT PLANT ENERGY EVALUATION FOR ITHACA AREA WASTEWATER TREATMENT FACILITY
MUNICIPAL WASTEWATER TREATMENT PLANT ENERGY EVALUATION FOR ITHACA AREA WASTEWATER TREATMENT FACILITY Agreement No. 7185 Prepared for THE NEW YORK STATE ENERGY RESEARCH AND DEVELOPMENT AUTHORITY Albany,
Town of New Castle Utility Department Introduction
Town of New Castle Utility Department Introduction Town of New Castle Utility Department Mission Statement Our commitment is to ensure that our customers receive high quality water and wastewater treatment
Energy Audits for Water and Wastewater Treatment Plants and Pump Stations
Energy Audits for Water and Wastewater Treatment Plants and Pump Stations Course No: M02-041 Credit: 2 PDH Ely Greenberg, P.E., CEM Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony
THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL
THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL ABSTRACT Timur Deniz, Ph.D., Thomas W. Friedrich, P.E.
Energy Self-Assessment Tools and Energy Audits for Water and Wastewater Utilities
Energy Self-Assessment Tools and Energy Audits for Water and Wastewater Utilities James Horne, US EPA Office of Wastewater Management Jason Turgeon, US EPA Region 1 Eric Byous, US EPA Region 9 Energy Use
Upper Occoquan Service Authority Centreville, Virginia A Case Study
Upper Occoquan Service Authority Centreville, Virginia A Case Study Dennis Clough, Managing Director Energy Systems Group Upper Occoquan Service Authority About the Upper Occoquan Service Authority 54
Bay Park Sewage Treatment Plant Super Storm Sandy Recovery
County of Nassau Department of Public Works Bay Park Sewage Treatment Plant Super Storm Sandy Recovery Edward P. Mangano County Executive Shila Shah-Gavnoudias, P.E. Commissioner of Public Works Bay Park
Wastewater Treatment System Rehabilitation Project
Wastewater Treatment System Rehabilitation Project An overview The City of Shelton, WA / January 2010 Before After SHELTON WASTEWATER TREATMENT IMPROVMENTS PROJECT Enabled by extensive grant-funding, loans
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
Elastomer Compatibility Testing of Renewable Diesel Fuels
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Elastomer Compatibility Testing
Energy Systems Integration
Energy Systems Integration A Convergence of Ideas Ben Kroposki, Bobi Garrett, Stuart Macmillan, Brent Rice, and Connie Komomua National Renewable Energy Laboratory Mark O Malley University College Dublin
Small PV Systems Performance Evaluation at NREL's Outdoor Test Facility Using the PVUSA Power Rating Method
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Small PV Systems Performance
NEVADA CITY WASTEWATER TREATMENT INQUIRY
NEVADA CITY WASTEWATER TREATMENT INQUIRY REASON FOR INVESTIGATION The 2003-2004 Grand Jury investigated the status of wastewater treatment in unincorporated Nevada County. This year, the Grand Jury investigated
DRAFT Public Outreach Document for What s an SSMP?
DRAFT Public Outreach Document for What s an SSMP? This easy to read document is developed and provided to interested parties to assist in educating cities, agencies, their management, elected officials
Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD. Trevor Ghylin, PE PhD
Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD Trevor Ghylin, PE PhD Outline Background Case Study: Sterno, Sweden (~1.8 MGD) 65% Aeration Energy Reduction Case Study:
During the past decade, the city of
An Advanced Pollution Control Facility s Conversion to Four-Stage Bardenpho to Improve Biological Nitrogen Removal Timur Deniz, Thomas W. Friedrich, and John Milligan During the past decade, the city of
St. Petersburg, FL: Vehicle Use of Recycled Natural Gas Derived from Wastewater Biosolids
U.S Department of Energy - Biomass 2014 St. Petersburg, FL: Vehicle Use of Recycled Natural Gas Derived from Wastewater Biosolids William Eleazer, PE Project Design Manager John Willis, PE, BCEE Project
Bio-P Removal- Principles and examples in MI and elsewhere S. Joh Kang, Ph.D., P.E. Tetra Tech, Inc. Ann Arbor, MI 2010 Presentation Outline Optimization of Chemicals and Energy Bio-P Removal - Review
Alberta Environment Standards for Advanced Waste Systems
Alberta Environment Standards for Advanced Waste Systems + Alberta Rural Organic Waste to Resources Network + George Neurohr Regional Municipal Engineer Grande Prairie, Alberta May 1, 2012 Contents: Introduction
Ann Arbor Wastewater Treatment Plant Facilities Renovations Project September 2015
Ann Arbor Wastewater Treatment Plant Facilities Renovations Project September 2015 The Facilities Master Plan was completed in 2004 and identified the need for improvements to the City of Ann Arbor s Wastewater
Wastewater Nutrient Removal
Wastewater Nutrient Removal An overview of phosphorus and nitrogen removal strategies Presented by: William E. Brown, P.E. Peter C. Atherton, P.E. Why are nutrients an issue in the environment? Stimulates
A New Empirical Relationship between Thrust Coefficient and Induction Factor for the Turbulent Windmill State
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy A New Empirical Relationship
CHAPTER 1 - EXECUTIVE SUMMARY
Chapter Page CHAPTER 1 - EXECUTIVE SUMMARY 1.1 Background 1-1 1.2 Purpose/ Objectives 1-1 1.3 Flow, Condition and Operation Assessment 1-3 1.4 Class A Biosolids 1-4 1.5 Summary of Recommendations 1-4 CHAPTER
OPERATIONS & MAINTENANCE FY 2012-2013 Adopted Budget
SERVICE DESCRIPTION To maintain all of the transferred and accepted infrastructure within the district including water, wastewater, and stormwater systems, streetlights, traffic signals, and landscaping
Reducing Data Center Loads for a Large-Scale, Net Zero Office Building
rsed Energy Efficiency & Renewable Energy FEDERAL ENERGY MANAGEMENT PROGRAM Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Energy Efficiency & Renewable Energy Executive summary
EXISTING WASTEWATER TREATMENT FACILITIES
Chapter 5 EXISTING WASTEWATER TREATMENT FACILITIES 5.1 THERESA STREET WWTF 5.1.1 Overview The Theresa Street WWTF is the larger of the two wastewater treatment facilities owned and operated by the City.
Roadmap to Energy Efficiency. for. Water and Wastewater Utilities
Roadmap to Energy Efficiency for Water and Wastewater Utilities Prepared by: Howard Steiman, P.E. ([email protected]) and Paul Doran, P.E. ([email protected]) R. W. Beck, Inc. 550 Cochituate Road Meditech
San Antonio College. Energy Systems Laboratory TEXAS ENGINEERING EXPERIMENT STATION TEXAS A&M UNIVERSITY SYSTEM
CLIMATE ACTION PLAN 2011 For: San Antonio College 1300 San Pedro Ave., San Antonio, TX 78212. (210) 486-0000 Prepared by: Energy Systems Laboratory TEXAS ENGINEERING EXPERIMENT STATION TEXAS A&M UNIVERSITY
5. TREATMENT FACILITIES
5. TREATMENT FACILITIES 5.1. Background... 1 5.2. Nine Springs Wastewater Treatment Plant... 1 5.2.1. Liquid Treatment Facilities... 3 5.2.2. Biosolids Disposal Facilities... 6 5.2.3. Operation and Maintenance
Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service
Experts Review of Aerobic Treatment Unit Operation and Maintenance Bruce Lesikar Texas AgriLife Extension Service Overview Overview of Aerobic Treatment Units Installing for accessibility to system components
MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC
Introduction MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC Aeration systems for conventional wastewater activated sludge
Sewerage Management System for Reduction of River Pollution
Sewerage Management System for Reduction of River Pollution Peter Hartwig Germany Content page: 1 Introduction 1 2 Total emissions 3 3 Discharge from the wastewater treatment plants 4 4 Discharge from
CHAPTER 10-2. Section 1 Inventory of Existing Sanitary Sewer Collection and Treatment Facilities
CHAPTER 10-2 SEWAGE COLLECTION AND TREATMENT FACILITIES Section 1 Inventory of Existing Sanitary Sewer Collection and Treatment Facilities 1.1 SANITARY SEWER COLLECTION SYSTEM The City of Washougal operates
Advanced Wastewater Treatment Process
7 th Workshop on Greenhouse Gas Inventories in Asia Possibly Co-benefit? Advanced Wastewater Treatment Process Tomonori ISHIGAKI Dept. of Environmental Solution Technology Ryukoku University, Japan Introductory
Optical Blade Position Tracking System Test
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Optical Blade Position Tracking
EXISTING WASTEWATER TREATMENT FACILITIES
Chapter 5 EXISTING WASTEWATER TREATMENT FACILITIES 5.1 THERESA STREET WWTF 5.1.1 Overview The Theresa Street WWTF is the larger of the two wastewater treatment facilities owned and operated by the City
Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues
LBNL-6129E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Liping Wang, Tianzhen Hong Environmental
Rules of Thumb Energy Efficiency in Buildings
Energy Efficiency in Buildings Energy Savings Cost Savings Increased Productivity Economic Development Other Standard lighting retrofits: $0.90-$1.20 per square foot. High-efficiency packaged and split
Energy Recovery from Wastewater Treatment Plants in the United States: A Case Study of the Energy-Water Nexus
Sustainability 2010, 2, 945-962; doi:10.3390/su2040945 OPEN ACCESS sustainability ISSN 2071-1050 www.mdpi.com/journal/sustainability Article Energy Recovery from Wastewater Treatment Plants in the United
Advanced Wastewater Treatment and Disposal Systems. Water and Wastewater Utility Operation and
Advanced Wastewater Treatment and Disposal Systems Water and Wastewater Utility Operation and Management for Tribes Preliminary Treatment Primary Treatment Secondary Treatment Tertiary Treatment Disinfection
Anish Jantrania (photo) and Allen Knapp
WATER QUALITY VERSUS PROCESS MONITORING CHARLES CITY COUNTY, VA PROJECT Anish Jantrania (photo) and Allen Knapp Anish Jantrania Technical Services Engineer Virginia Department of Health Richmond, VA 23219,
TABLE OF CONTENTS EXECUTIVE SUMMARY...1 1.0 DESCRIPTION OF EXISTING CONDITIONS... 1-1. 1.1 Population... 1-1. 1.2 Wastewater Flows...
TABLE OF CONTENTS EXECUTIVE SUMMARY...1 1.0 DESCRIPTION OF EXISTING CONDITIONS... 1-1 1.1 Population... 1-1 1.2 Wastewater Flows... 1-1 1.3 Existing Wastewater Facilities... 1-2 1.3.1 City of Celina...
ESPC Life of Contract (LOC) Plan:
ESPC Life of Contract (LOC) Plan: Documents Management and Checklist for Savings Performance Contracts (ESPC) (Contract Number), (Date Amended), (Contributors) (SITE) ENERGY SAVINGS PERFORMANCE CONTRACT
A Model Environmental Management System FOR LOCAL GOVERNMENTS
L O C A L G O V E R N M E N T S E R I E S A Model Environmental Management System FOR LOCAL GOVERNMENTS T E X A S C O M M I S S I O N O N E N V I R O N M E N T A L Q U A L I T Y Contents PART I: INTRODUCTION
5. Environmental Analysis
5.11 The potential for adverse impacts on utilities and service systems was evaluated based on information concerning current service levels and the ability of the service providers to accommodate the
Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc. [email protected] 201 529 5151 X 7167
Nutrient Removal at Wastewater Treatment Facilities Nitrogen and Phosphorus Gary M. Grey HydroQual, Inc. [email protected] 201 529 5151 X 7167 1 Agenda Nitrification and Denitrification Fundamentals
Package Treatment Plant Policy and Procedure
Package Treatment Plant Policy and Procedure PURPOSE There has been increased interest in the use of package treatment plants for new development proposals in the County. Current review procedures are
Consumers Energy Business Energy Efficiency Program
Consumers Energy Business Energy Efficiency Program Identifying Energy Saving Opportunities in Water and Wastewater Treatment Leila Saber, Consumers Energy Business Energy Efficiency Program October 20,
Wind Forecasting stlljectives for Utility Schedule and Energy Traders
NREUCP 500 24680 UC Category: 1210 Wind Forecasting stlljectives for Utility Schedule and Energy Traders Marc N. Schwartz National Renewable Energy Laboratory Bruce H. Bailey A WS Scientific, Inc. Presented
Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water
United States Office of Water EPA 916-F-01-032 Environmental Protection (4606) July 2001 Agency Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows
Energy saving technology to deliver the fastest returns. Top 10 energy saving options
Energy saving technology to deliver the fastest returns Top 10 energy saving options How can you increase efficiency, reduce costs and cut your carbon emissions? Unstable energy prices, increased costs,
Facility Classification Standards
Facility Classification Standards Approval Date: April 3, 2009 Effective Date: April 3, 2009 Approved By: Nancy Vanstone, Deputy Minister Version Control: Replaces Facility Classification Standards dated
A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS
GEORGIA DEPARTMENT OF HUMAN RESOURCES ENVIRONMENTAL HEALTH SECTION A HOMEOWNERS GUIDE TO ON-SITE SEWAGE MANAGEMENT SYSTEMS March 12, 2002 WHAT IS AN ON-SITE SEWAGE MANAGEMENT SYSTEM An on-site sewage management
Application Form 2E. Facilities Which Do Not Discharge Process Wastewater
United States Environmental Protection Agency Office of Water Enforcement and Permits Washington, DC 20460 EPA Form 3510-2E Revised August 1990 Permits Division Application Form 2E Facilities Which Do
Energy Efficiency RFP Guidance
Energy Efficiency RFP Guidance For Water-Wastewater Projects Acknowledgments The information in this document is based on the experience and input of a number of CEE member efficiency program administrators
WISCONSIN WASTEWATER OPERATORS ASSOCIATION
Integrity. People. Knowledge. WISCONSIN WASTEWATER OPERATORS ASSOCIATION ANNUAL CONFERENCE GREEN BAY Resources. MEETING LOW LEVEL PHOSPHORUS LIMITS BY CHEMICAL ADDITION WHAT IS PHOSPHORUS Atomic # 15 Electron
NPDES Permit No. IL0052639. Notice No. IL0052639-12.TTL. Public Notice Beginning Date: June 15, 2012. Public Notice Ending Date: July 16, 2012
NPDES Permit No. IL0052639 Notice No. IL0052639-12.TTL Public Notice/Fact Sheet Issued By: Public Notice Beginning Date: June 15, 2012 Public Notice Ending Date: July 16, 2012 National Pollutant Discharge
COOLING WATER MANAGEMENT
COOLING WATER MANAGEMENT Intent To minimize the carbon-footprint, water usage and environmental impact of HVAC cooling systems and process cooling systems, generally by optimizing the control of water
GE Power & Water Water & Process Technologies. Water Treatment Solutions for Unconventional Gas
GE Power & Water Water & Process Technologies Water Treatment Solutions for Unconventional Gas Addressing Today s Challenges Today, corporations, individuals and governmental bodies alike are focused on
Floating Treatment Wetland Technology: Nutrient Removal from Wastewater
Floating Treatment Wetland Technology: Nutrient Removal from Wastewater This case study illustrates the Floating Island International (FII) patented floating treatment wetland (FTW) technology and its
System Advisor Model, SAM 2014.1.14: General Description
System Advisor Model, SAM 2014.1.14: General Description Nate Blair, Aron P. Dobos, Janine Freeman, Ty Neises, and Michael Wagner National Renewable Energy Laboratory Tom Ferguson, Paul Gilman, and Steven
Life cycle energy analysis of water use system in Ara river watershed
Life cycle energy analysis of water use system in Ara river watershed Hiroaki FURUMAI Professor, Research Center for Environment Technology University of Tokyo IWA Workshop on and & Loss Tokyo, 8 April
FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST
FAST Owner s Manual FOR USE WITH (NSF Std 40 & 245) MicroFAST 0.5, 0.75, 0.9, 1.5 (non-nsf certified) MicroFAST 3.0, 4.5, 9.0 (ETV/EPA tested) RetroFAST 0.150, 0.250, 0.375 NitriFAST 0.5, 0.75, 0.9, 1.5,
NPDES Permit No. IL0020737. Notice No. SKT:13120601.bah. Public Notice Beginning Date: April 9, 2014. Public Notice Ending Date: May 9, 2014
Public Notice/Fact Sheet Issued By: Notice No. SKT:13120601.bah Public Notice Beginning Date: April 9, 2014 Public Notice Ending Date: May 9, 2014 National Pollutant Discharge Elimination System (NPDES)
Guidance on applying for approval of installation of a commercial onsite wastewater system
Guidance on applying for approval of installation of a commercial onsite wastewater system This factsheet is designed to assist you to complete an Application to construct or install an apparatus for the
TOWN OF SAUGEEN SHORES WATER AND SANITARY SEWER SERVICING MASTER PLAN 2014 REPORT
TOWN OF SAUGEEN SHORES WATER AND SANITARY SEWER SERVICING MASTER PLAN 2014 REPORT TOWN OF SAUGEEN SHORES WATER AND SANITARY SEWER SERVICING MASTER PLAN 2014 REPORT April 1, 2015 B. M. ROSS AND ASSOCIATES
Integrated Tools for Multifamily Green Asset Management. Energy Upgrade CA Web Portal Funding Finder Compass Portfolio Tracker Webinar May 22, 2012
Integrated Tools for Multifamily Green Asset Management Energy Upgrade CA Web Portal Funding Finder Compass Portfolio Tracker Webinar May 22, 2012 Webinar Agenda 2 Introductions Energy Upgrade California
Aquatera 2015/16 Business Plan Highlights
Who We Are Aquatera 2015/16 Business Plan Highlights Aquatera is a full-service utility corporation the provider of choice for governments, businesses, and communities. Our business is to provide high-quality
Operation and Maintenance of Onsite Waster Systems in Maryland. A growing challenge for the industry and regulators
Operation and Maintenance of Onsite Waster Systems in Maryland A growing challenge for the industry and regulators Operation and Maintenance of Onsite Waster Systems in Maryland New law and regulations
Clean State Energy Actions 2011 Update. north carolina. Energy efficiency included in North Carolina s REPS
Energy Efficiency Building Energy Codes Utility Demand-Side-Management Utility Rate Realignment Energy Savings Targets/Energy Efficiency Resource Standards 2009 North Carolina Energy Conservation Code
How To Manage The Lott Alliance
Asset Management Program Executive Summary Tools for Achieving Expected Levels of Service Board of Directors Graeme Sackrison Doug Mah Bruce Zeller Cathy Wolfe City of Lacey City of Olympia City of Tumwater
COPYRIGHT MATERIAL. Geof Syphers, PE, LEED AP BD+C Codding Enterprises 2010
COPYRIGHT MATERIAL This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of the author is prohibited.