A22. Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Pushbutton Switch (Cylindrical 22/25-dia.) List of Models
|
|
|
- Kelly Peters
- 10 years ago
- Views:
Transcription
1 Pushbutton Switch (Cylindrical 22/25-dia.) CSM DS_E_8_3 Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Lever for easily mounting and removing the Switch Unit. Increase wiring efficiency with three-row mounting of Switch Blocks. Finger protection mechanism on Switch Unit provided as a standard feature. Use 25-dia. ring to install in 25-dia. panel cutouts. Mounted using either open-type (fork-type) or closed-type (round-type) crimp terminals. IP65 oil resistance (non-lighted models) IP65 (lighted models) Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions on page 23. List of Models Non-lighted Pushbutton Switches Lighted Pushbutton Switches Appearance Model number Appearance Model number Appearance Model number Flat -F Projected -C Projected L-T Round Square Projected -T Guard -D Full guard L-G Round Full guard -G Mushroom Small (30 dia.) -S Half guard L-H Half guard -H Mushroom Mushroom Medium (40 dia.) -M Projected L-C Square Guard L-D 1
2 Model Number Structure Model Number Legend... Shipped as a set which includes the Pushbutton, Lamp (lighted type only), and Switch. For information on combinations, refer to Ordering Information on pages 3 to 6. (1) (2) (3) (4) (5) (6) L - T R - 12A - 10 M (1) Type Code No symbol L Non-lighted Lighted (2) Flange Shape Non-lighted Code F T G H C D S M Lighted Code T G H C D Description Flat Projected Round Full-guard Half-guard Square Projected Full-guard Mushroom Small (30 dia.) Round Mushroom Medium (40 dia.) Description Projection Round Full-guard Half-guard Square Projection Full-guard (3) Illumination Color Description Description Code R Red G Green Y Yellow W White A Blue B Black* * For non-lighted type only (4) Light Source Without Voltage Reduction Unit Code Operating Voltage No symbol Non-lighted 6A 6 VAC/VDC 12A LED 12 VAC/VDC 24A 24 VAC/VDC 5 Incandescent 5 VAC/VDC VAC/VDC 24 lamp 24 VAC/VDC With Voltage Reduction Unit Code Operating Voltage T1 100 VAC LED T2 200 VAC Note: LED incorporates the 24-VAC/ VDC type. (5) Contacts Code Description DPST-NO 02 DPST-NC Note: 1. The contact ratings are for standard loads. For microloads, select from the accessories on page Refer to page 13 for contact ratings. (6) Switch Action Code Description M Momentary A Alternate Note: 1. Momentary operation: Self-resetting 2. Alternate operation: Self-holding The Socket Unit holds and the Operation Unit resets. Specifications: See pages 13 to 14. Precautions for correct use: Refer to page 23. Dimensions: Refer to page16. Accessories and tools: See pages 10 to 12. 2
3 Ordering Information Completely Assembled... Shipped as a set which includes the Pushbutton, Lamp (lighted type only), and Switch. Non-lighted (Round Type) Round/Flat type -F Round/Projection type -T Round/Full-guard type -G Round/Half-guard type -H Round/Small-size Mushroom type (30-dia. head) -S Round/Medium-size Mushroom type (40-dia head) -M Note: The contact ratings are for standard loads. Operation Momentary operation (self-resetting) Alternate operation (self-holding) Appearance Output Set Set -F@-10M -F@-10A -F@-01M -F@-01A + -F@-11M -F@-11A DPST-NO -F@-20M -F@-20A DPST-NC -F@-02M -F@-02A -T@-10M -T@-10A -T@-01M -T@-01A + -T@-11M -T@-11A + -T@-20M -T@-20A + -T@-02M -T@-02A -G@-10M -G@-10A -G@-01M -G@-01A + -G@-11M -G@-11A + -G@-20M -G@-20A + -G@-02M -G@-02A -H@-10M -H@-10A -H@-01M -H@-01A + -H@-11M -H@-11A + -H@-20M -H@-20A + -H@-02M -H@-02A -S@-10M -S@-01M + -S@-11M + -S@-20M + -S@-02M -M@-10M --- -M@-01M + -M@-11M + -M@-20M + -M@-02M Illumination color R (red) Y (yellow) G (green) W (white) A (blue) B (black) Non-lighted (Square Type) Note: The contact ratings are for standard loads. Operation Momentary operation (self-resetting) Alternate operation (self-holding) Appearance Output Set Set Square/Projection type -C -C@-10M -C@-01M -C@-10A -C@-01A + -C@-11M -C@-11A + -C@-20M -C@-20A + -C@-02M -C@-02A Square/Guard type -D@-10M -D@-10A -D -D@-01M -D@-01A + -D@-11M -D@-11A + -D@-20M -D@-20A + -D@-02M -D@-02A Illumination color R (red) Y (yellow) G (green) W (white) A (blue) B (black) Individual models: Refer to pages 7 to 9. (The Pushbutton, Lamp, and Switch can be ordered Specifications: See pages 13 to 14. Dimensions: Refer to page 16. Accessories and tools: See pages 10 to 12. 3
4 Ordering Information Completely Assembled...Shipped as a set which includes the Pushbutton, Lamp (lighted type only), and Switch. Lighted (Round Type) Momentary operation Alternate operation Operation (self-resetting) (self-holding) Appearance Output Lighting Operating voltage Set Set 6 VAC/VDC L-T@-6A-10M L-T@-6A-10A 12 VAC/VDC L-T@-12A-10M L-T@-12A-10A 24 VAC/VDC L-T@-24A-10M L-T@-24A-10A 6 VAC/VDC L-T@-6A-01M L-T@-6A-01A 12 VAC/VDC L-T@-12A-01M L-T@-12A-01A 24 VAC/VDC L-T@-24A-01M L-T@-24A-01A Round/Projection type LED lighting (without Voltage Reduction Unit) L-T Round/Projection type LED voltage-reduction lighting (with Voltage Reduction Unit) L-T Note: The contact ratings are for standard loads. LED 6 VAC/VDC L-T@-6A-11M L-T@-6A-11A 12 VAC/VDC L-T@-12A-11M L-T@-12A-11A 24 VAC/VDC L-T@-24A-11M L-T@-24A-11A 6 VAC/VDC L-T@-6A-20M L-T@-6A-20A 12 VAC/VDC L-T@-12A-20M L-T@-12A-20A 24 VAC/VDC L-T@-24A-20M L-T@-24A-20A 6 VAC/VDC L-T@-6A-02M L-T@-6A-02A 12 VAC/VDC L-T@-12A-02M L-T@-12A-02A 24 VAC/VDC L-T@-24A-02M L-T@-24A-02A 100 VAC L-T@-T1-10M L-T@-T1-10A 200 VAC L-T@-T2-10M L-T@-T2-10A 100 VAC L-T@-T1-01M L-T@-T1-01A 200 VAC L-T@-T2-01M L-T@-T2-01A 100 VAC L-T@-T1-11M L-T@-T1-11A 200 VAC L-T@-T2-11M L-T@-T2-11A 100 VAC L-T@-T1-20M L-T@-T1-20A 200 VAC L-T@-T2-20M L-T@-T2-20A 100 VAC L-T@-T1-02M L-T@-T1-02A 200 VAC L-T@-T2-02M L-T@-T2-02A Momentary operation Alternate operation Operation (self-resetting) (self-holding) Appearance Output Lighting Operating voltage Set Set Round/Half-guard type LED lighting L-H@-24A-10M L-H@-24A-10A (without Voltage Reduction Unit) L-H L-H@-24A-01M L-H@-24A-01A Illumination color R (red) Y (yellow) G (green) W (white) A (blue) Illumination color Round/Half-guard type LED voltage-reduction lighting (with Voltage Reduction Unit) L-H Note: The contact ratings are for standard loads. LED 24 VAC/VDC L-H@-24A-11M L-H@-24A-20M L-H@-24A-02M L-H@-24A-11A L-H@-24A-20A L-H@-24A-02A 100 VAC L-H@-T1-10M L-H@-T1-10A 200 VAC L-H@-T2-10M L-H@-T2-10A 100 VAC L-H@-T1-01M L-H@-T1-01A 200 VAC L-H@-T2-01M L-H@-T2-01A 100 VAC L-H@-T1-11M L-H@-T1-11A 200 VAC L-H@-T2-11M L-H@-T2-11A 100 VAC L-H@-T1-20M L-H@-T1-20A 200 VAC L-H@-T2-20M L-H@-T2-20A 100 VAC L-H@-T1-02M L-H@-T1-02A 200 VAC L-H@-T2-02M L-H@-T2-02A R (red) Y (yellow) G (green) W (white) A (blue) Individual models: Refer to pages 7 to 9. (The Pushbutton, Lamp, and Switch can be ordered separately.) Specifications and dimensions: See pages 13 to 16. Accessories and tools: See pages 10 to 12. 4
5 Ordering Information Completely Assembled... Shipped as a set which includes the Pushbutton, Lamp (lighted type only), and Switch. Lighted (Round Type) Momentary operation Alternate operation Operation (self-resetting) (self-holding) Appearance Output Lighting Operating voltage Set Set Round/Full-guard type 6 VAC/VDC L-G@-6A-10M L-G@-6A-10A LED lighting 12 VAC/VDC L-G@-12A-10M L-G@-12A-10A (without Voltage Reduction Unit) 24 VAC/VDC L-G@-24A-10M L-G@-24A-10A L-G 6 VAC/VDC L-G@-6A-01M L-G@-6A-01A 12 VAC/VDC L-G@-12A-01M L-G@-12A-01A 24 VAC/VDC L-G@-24A-01M L-G@-24A-01A Round/Full-guard type LED voltage-reduction lighting (with Voltage Reduction Unit) L-G Note: The contact ratings are for standard loads. LED 6 VAC/VDC L-G@-6A-11M L-G@-6A-11A 12 VAC/VDC L-G@-12A-11M L-G@-12A-11A 24 VAC/VDC L-G@-24A-11M L-G@-24A-11A 6 VAC/VDC L-G@-6A-20M L-G@-6A-20A 12 VAC/VDC L-G@-12A-20M L-G@-12A-20A 24 VAC/VDC L-G@-24A-20M L-G@-24A-20A 6 VAC/VDC L-G@-6A-02M L-G@-6A-02A 12 VAC/VDC L-G@-12A-02M L-G@-12A-02A 24 VAC/VDC L-G@-24A-02M L-G@-24A-02A 100 VAC L-G@-T1-10M L-G@-T1-10A 200 VAC L-G@-T2-10M L-G@-T2-10A 100 VAC L-G@-T1-01M L-G@-T1-01A 200 VAC L-G@-T2-01M L-G@-T2-01A 100 VAC L-G@-T1-11M L-G@-T1-11A 200 VAC L-G@-T2-11M L-G@-T2-11A 100 VAC L-G@-T1-20M L-G@-T1-20A 200 VAC L-G@-T2-20M L-G@-T2-20A 100 VAC L-G@-T1-02M L-G@-T1-02A 200 VAC L-G@-T2-02M L-G@-T2-02A Illumination color R (red) Y (yellow) G (green) W (white) A (blue) Individual models: Refer to pages 7 to 9. (The Pushbutton, Lamp, and Switch can be ordered separately.) Specifications and dimensions: Refer to pages 13 to 16. Accessories and tools: See pages 10 to 12. 5
6 Ordering Information Completely Assembled...Shipped as a set which includes the Pushbutton, Lamp (lighted type only), and Switch. Lighted (Square Type) Momentary operation Alternate operation Operation (self-resetting) (self-holding) Appearance Output Lighting Operating voltage Set Set Square/Projection type LED lighting L-C@-24A-10M L-C@-24A-10A (without Voltage Reduction Unit) L-C L-C@-24A-01M L-C@-24A-01A + 24 VAC/VDC L-C@-24A-11M L-C@-24A-11A + L-C@-24A-20M L-C@-24A-20A + L-C@-24A-02M L-C@-24A-02A Square/Projection type LED 100 VAC L-C@-T1-10M L-C@-T1-10A LED voltage-reduction lighting 200 VAC L-C@-T2-10M L-C@-T2-10A (with Voltage Reduction Unit) 100 VAC L-C@-T1-01M L-C@-T1-01A L-C 200 VAC L-C@-T2-01M L-C@-T2-01A VAC L-C@-T1-11M L-C@-T1-11A 200 VAC L-C@-T2-11M L-C@-T2-11A VAC L-C@-T1-20M L-C@-T1-20A 200 VAC L-C@-T2-20M L-C@-T2-20A + Note: The contact ratings are for standard loads. 100 VAC L-C@-T1-02M L-C@-T1-02A 200 VAC L-C@-T2-02M L-C@-T2-02A Momentary operation Alternate operation Operation (self-resetting) (self-holding) Appearance Output Lighting Operating voltage Set Set Square/Full-guard type LED lighting L-D@-24A-10M L-D@-24A-10A (without Voltage Reduction Unit) L-D L-D@-24A-01M L-D@-24A-01A Illumination color R (red) Y (yellow) G (green) W (white) A (blue) Illumination color + 24 VAC/VDC L-D@-24A-11M L-D@-24A-11A + + Square/Full-guard type LED voltage-reduction lighting (with Voltage Reduction Unit) L-D Note: The contact ratings are for standard loads. LED L-D@-24A-20M L-D@-24A-02M L-D@-24A-20A L-D@-24A-02A 100 VAC L-D@-T1-10M L-D@-T1-10A 200 VAC L-D@-T2-10M L-D@-T2-10A 100 VAC L-D@-T1-01M L-D@-T1-01A 200 VAC L-D@-T2-01M L-D@-T2-01A 100 VAC L-D@-T1-11M L-D@-T1-11A 200 VAC L-D@-T2-11M L-D@-T2-11A 100 VAC L-D@-T1-20M L-D@-T1-20A 200 VAC L-D@-T2-20M L-D@-T2-20A 100 VAC L-D@-T1-02M L-D@-T1-02A 200 VAC L-D@-T2-02M L-D@-T2-02A R (red) Y (yellow) G (green) W (white) A (blue) Individual models: Refer to pages 7 to 9. (The Pushbutton, Lamp, and Switch can be ordered separately.) Specifications and dimensions: See pages 13 to 16. Accessories and tools: See pages 10 to 12. 6
7 Ordering Information Subassembled...The Pushbutton, Lamp, or Switch can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts. Lighted Models Lighted Models Non-lighted Models (without Voltage Reduction Unit) (with Voltage Reduction Unit) Pushbutton Pushbutton Pushbutton Lamp Lamp Incandescent lamp LED LED Switch Switch (without Voltage Reduction Unit) Switch (with Voltage Reduction Unit) Ordering set combinations: Refer to pages 3 to 6. Specifications and dimensions: See pages 13 to 16. Accessories and tools: See pages 10 to 12. 7
8 Ordering Information Subassembled... The Pushbutton, Lamp, or Switch can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts. Pushbutton Non-lighted Sealing IP65 oil-resistant models Flat type Projection type Full-guard type Half-guard type Appearance Color Model Model Model Model Red -FR -TR -GR -HR Green -FG -TG -GG -HG Yellow -FY -TY -GY -HY White -FW -TW -GW -HW Blue -FA -TA -GA -HA Black -FB -TB -GB -HB Sealing Appearance Round/Mushroom type (30-dia. head) IP65 oil-resistant models Round/Mushroom type Square/Projection type (40-dia. head) Square/Full-guard type Color Model Model Model Model Red -SR -MR -CR -DR Green -SG -MG -CG -DG Yellow -SY -MY -CY -DY White -SW -MW -CW -DW Blue -SA -MA -CA -DA Black -SB -MB -CB -DB Lighted Sealing IP65 Projection type Full-guard type Half-guard type Appearance Color Model Model Model Red L-TR L-GR L-HR Green L-TG L-GG L-HG Yellow L-TY L-GY L-HY White L-TW L-GW L-HW Blue L-TA L-GA L-HA Note: Common to incandescent lamps and LED lamps. Sealing IP65 Square/Projection type Square/Full-guard type Appearance Color Model Model Red L-CR L-DR Green L-CG L-DG Yellow L-CY L-DY White L-CW L-DW Blue L-CA L-DA Ordering set combinations: Refer to pages 3 to 6. Specifications and dimensions: See pages 13 to 16. Accessories and tools: See pages 10 to 12. 8
9 Ordering Information Subassembled...The Pushbutton, Lamp, or Switch can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts. Lamp LED Lamp Operating voltage 6 VAC/VDC 12 VAC/VDC 24 VAC/VDC Appearance LED Color Model Model Model Red -6AR -12AR -24AR AC Green -6AG -12AG -24AG and DC Yellow *2-6AY -12AY -24AY Blue -6AA -12AA -24AA *1. For voltage-reduction lighting, use the -24A@. Only 24-V LED lamps can be used. *2. Used when the Pushbutton color is yellow or white. Incandescent Lamp Appearance Operating voltage 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC Switch (Standard Load) No Voltage Reduction Unit Classification Appearance Non-lighted Lighted Operation Momentary Alternate Momentary Alternate Contacts Model Model Model Model -10M -10A L-10M L-10A -01M -01A L-01M L-01A Standard + -11M -11A L-11M L-11A load + -20M -20A L-20M L-20A + -02M -02A L-02M L-02A Voltage Reduction Unit Classification 110 VAC, Lighted 220 VAC, Lighted Appearance Operation Momentary Alternate Momentary Alternate Contacts Model Model Model Model L-10M-T1 L-10A-T1 L-10M-T2 L-10A-T2 L-01M-T1 L-01A-T1 L-01M-T2 L-01A-T2 Standard + L-11M-T1 L-11A-T1 L-11M-T2 L-11A-T2 load + L-20M-T1 L-20A-T1 L-20M-T2 L-20A-T2 + L-02M-T1 L-02A-T1 L-02M-T2 L-02A-T2 *1. A DPST-NO model is shown here as an example. *2. For a model with a Voltage Reduction Unit, use the -24A@. Only 24-V LED lamps can be used. Ordering set combinations: Refer to pages 3 to 6. Specifications and dimensions: See pages 13 to 16. Accessories and tools: See pages 10 to 12. 9
10 Ordering Information Accessories (Order Separately) Accessories Item Appearance Classification Model Remarks Standard load -10 Microload -10S Standard load Microload S Order Switch Blocks to add an Switch Blocks DPST-NO Microload -20S Block (for standard Standard load -20 (-10) or (-01) Switch loads) or to replace a DPST-NC Standard load -02 Switch Block. Microload -02S + Standard load -11 Microload -11S Direct lighting -TN Lamp Sockets Voltage-reduction 110 VAC -T1 Used when changing the lighting method. lighting 220 VAC -T2 (LED only) Mounting Latches Legend Plate Frames Standard size Large size For momentary models Provided as standard. Order Mounting Latches only when mounting Switch Blocks or Lamp Sockets that are purchased individually. For alternate models White With Snap-in Legend Plate Red (Without text) Black Without Snap-in Legend Plate White With Snap-in Legend Plate Red (Without text) Black Without Snap-in Legend Plate Z-3321 Z-3322 Z-3323 Z-3320 Z-3331 Z-3332 Z-3333 Z-3330 Snap-in Legend Plate is acrylic. Snap-in Legend Plate is acrylic. Lock Ring Round Z-3360 This Lock Ring is used when a more secure lock feature is required. Metallic Bezel Rings For flat or projection models Z-3580 Replace with the standard model. Material: Copper alloy-nickel chrome plating For full-guard models Z-3582 Cannot be used with the M22. Sealing Caps For flat models For projection models Z-3600F Z-3600T For full-guard models Z-3600G Red Z-30TR Green Z-30TG Color Caps Yellow Z-30TY White Z-30TW Blue Z-30TA For For projection, full-guard, or half-guard models Z-3490 Caps For M22 For round models Z-3495 Three-throw Spacer --- Z-3003 Hole Plug Round Z-3530 Control Boxes (Enclosures) One hole Z-B101 Z-B201 One hole, yellow box (for emergency stop) Z-B101Y Z-B201Y Two holes Z-B102 Z-B202 Three holes Z-B103 Z-B203 Used to prevent dust or water from entering the Operation Unit (Pushbutton, etc.). Color: opaque Material: silicon Used for changing the Pushbutton color of the (round) Pushbutton Switches. Cannot be used, however, with Half-guard Switches. Material: polycarbonate resin Used when mounting three Nonlighted Switches. Cannot be used with Alternate action type, knob-type Selector, and Keytype Selector because of the structure. Mushroom-type Switch provides an Z- 3003, three-throw spacer. (See page 28.) Can be plugged into pre-cut panel holes for future expansion. The color is black. Color: Black For those designed Z-B1@, DPST-NO or DPST-NC Switches cannot be used. Z-B2@ Control Boxes, -series alternate operation models, and DPST-NO, DPST-NC, and + contacts cannot be used. Material: Polycarbonate resin Connectors Applicable cable diameter (mm) 7 to 9 dia. Z Plastic connector used to extend a cable from the Switch Box. (See 9 to 11 dia. Z- 9 to 11 dia. Z page 27.) 10
11 Ordering Information Item Appearance Classification Model Remarks 25-dia. Ring --- Z-R25 Use when mounting to a panel with a 25-dia. hole. For details, refer to page 18. Since this is not attached to the main body, order separately. 30-dia. Resin Attachment Round Z-A30 Use when mounting to a panel with a 30-dia. hole. For details, refer to page 20. Lock Plate --- Z-3380 Use to fix the lever on the Switch. Simple Protective Cover --- Z-3700 Prevents foreign matter entering into the Switch from the back of the panel. Specifications: See pages 13 to 14. Precautions for correct use: See page 23. Dimensions: See page 16. Accessories and tools: See pages 10 to
12 Ordering Information Item Appearance Classification Model Remarks Black Z-3443B Without text Red Z-3443R White Z-3443W Transparent Z-3443C White text on red Z-3443R-2 background STOP Z-3443R-4 Attached to the Standard-size Legend Plate Standard Z-3443B-1 size START Z-3443B-3 Frame. (See page 28.) ON Z-3443B-5 Material: Acrylic With text White text on OFF Z-3443B-6 Snap-in black background UP Z-3443B-7 Legend Plates DOWN Z-3443B-8 POWER ON Z-3443B-9 OFF-ON Z-3443B-10 Large size Without text Black Z-3453B Used as an Emergency Red Z-3453R Stop Switch Legend White Z-3453W Plate. (See page 28.) Material: Acrylic Transparent Z-3453C For Emergency Stop yellow back- Black text on 60-dia. round plate with black letters Z EMERGENCY STOP is on a yellow background engraved on the plate. Used 90-dia. round plate with black letters as an Emergency Stop Switch ground on a yellow background Z Switch Legend Plate No print (Round) Z-3460 Character Films Z After printing on a film, affix to the indicator plate of Character Z print the Lighted Pushbutton START Z (Round) Switch. (The back is STOP Z coated with adhesive.) No print (Square) Z-3480 Tools Item Appearance Classification Model Remarks Lamp Extractor --- Z-3901 Rubber tool used to easily replace Lamps Tightening Wrench --- Z-3905 Used to tighten mounting nuts from the back of the panel and to replace the cap of the Lighted Emergency Switch. Cap Tightening Tool --- Z-3908 Used for replacing the cap of the Halfguard Pushbutton Switch. Cap Puller --- A3PJ-5080 Used for removing the cap from the Pushbutton of the Square Lighted Pushbutton Switch. Specifications: See pages 13 to 14. Precautions for correct use: See page 23. Dimensions: See page 16. Accessories and tools: See pages 10 to
13 Specifications Approved Standard Ratings UL, cul (File No. E41515) 6 A at 220 VAC, 10 A at 110 VAC Note: Only Switch Blocks and Lamp Sockets are recognized by UL. Refer to Page 10 for the model numbers. EN (Low Voltage Directive) 3 A at 220 VAC CCC (GB ) 3 A at 240 VAC, 1.5 A at 24 VDC Ratings Contacts (Standard Load) Contacts (Standard Load) 10A Rated voltage Note: 1. The above ratings were obtained by conducting tests under the following conditions. (1) Ambient temperature: 20±2 C (2) Ambient humidity: 65±5% RH (3) Operating frequency: 20 operations/minute 2. Minimum applicable load: 10 ma at 5 VDC Contacts (Microload) Rated applicable load Minimum applicable load Inductive load Rated current (A) Resistive load Inductive load Resistive load 24 VAC VAC VAC VAC VAC VDC VDC VDC VDC ma at 24 VDC (Resistive load) 1 ma at 5 VDC LED Indicators Rated voltage Rated current Operating voltage 6 VAC/VDC 6 VAC/VDC±5% 12 VAC/VDC 8 ma 12 VAC/VDC±5% 24 VAC/VDC 24 VAC/VDC±5% Incandescent Lamp Rated voltage Rated current Operating voltage 6 VAC/VDC 200 ma 5 VAC/VDC 14 VAC/VDC 80 ma 12 VAC/VDC 28 VAC/VDC 40 ma 24 VAC/VDC Voltage-reduction Lighting Rated voltage 110 VAC 220 VAC Rated current 8 ma Applicable lamp Operating voltage (BA9S/Base: 13) 100 VAC (95 to 115 V) LED Lamp 200 VAC (-24A@) (190 to 230 V) 13
14 Specifications Characteristics Item Allowable operating frequency Mechanical Type Non-lighted models: -F -T -G -H -S -M -C -D *1. Malfunction within 1 ms. *2. With no icing or condensation. *3. Degree of protection from the front of the panel. Pushbutton Switches Lighted models: L-T L-G L-H L-C L-D Momentary operation: 60 operations/minute max. Operating Characteristics (for /) * Rotation torque for Knob-type Selector and Key-type Selector Switches. Knob-type Selector Switches Non-lighted model: S Lighted model: W Key-type Selector Switch Non-lighted model: K Manual reset: 30 operations/minute max. Automatic reset: 30 operations/minute max. Electrical 30 operations/minute max. --- Insulation resistance 100 MΩ min. (at 500 VDC) Contact Standard load 100 mω max. (initial value) resistance Microload 100 mω max. (initial value) Dielectric strength Between terminals of same polarity Between each terminal and ground Vibration Malfunction *1 resistance 2,500VAC, 50/60Hz for 1min 2,500VAC, 50/60Hz for 1min Malfunction *2: 10 to 55 Hz, 1.5-mm double amplitude Indicator Shock Destruction 1,000 m/s 2 max. 1,000 m/s 2 max. 1,000 m/s 2 max. 1,000 m/s 2 max. 1,000 m/s 2 max. 1,000 m/s 2 max. resistance Malfunction *1 1,000 m/s 2 max. 600 m/s 2 max. 1,000 m/s 2 max. 600 m/s 2 max m/s 2 max. 600 m/s 2 max. Durability Mechanical Electrical Ambient operating temperature * 2 Ambient operating humidity Ambient storage temperature *2 Degree of protection *3 Electric shock protection class PTI (tracking characteristic) Degree of contamination Item Total travel force (TTF) max. Total travel (TT) Resetting force (RF) min. Momentary operation: 5,000,000 operations min. 500,000 operations min. 500,000 operations min. 500,000 operations min. 100,000 operations min. 100,000 operations min. 500,000 operations min. 500,000 operations min. 20 C to 70 C 20 C to 55 C 20 C to 70 C 20 C to 55 C 20 C to 70 C 20 C to 55 C IP65 (oil-resistant) IP65 IP65 (oil-resistant) 35% to 85% RH 40 C to 70 C Class II (IEC ) IP65 IP65 (oil-resistant) Type Pushbutton Switches Knob-type Selector Key-type Selector Switch Lighted Nonlighted Pushbutton Manual reset Automatic reset Manual reset Automatic reset Switches -F -T -G -H -C -D -S -M L-T L-G L-H L-C L-D S W 0.25 N m for two notches * 29.4 N 0.34 N m* 0.34 N m for three notches * Approx. 90 for two notches 5.5 mm max. (Approx. 45 for three notches) K M IP N m for two notches * 0.34 N m* 0.34 N m for three notches * Approx. 90 for two notches (Approx. 45 for three notches) N m max.* N m max.*
15 Nomenclature Model Structure Lo c k Ring Push b utton Available Colors Non-lighted: Red, Green, Yellow, White, Blue, Black Lighted: Red, Green Yellow, White, Blue Lamp Light Source LED lamp Incandescent lamp Switch The above illustration shows a lighted model. Contacts,, +, +, + (Minimum applicable load: 10 ma at 5 VDC) Lighting Method Non-lighted Lighted (without Voltage Reduction Unit) Lighted (with Voltage Reduction Unit) 15
16 Dimensions (Unit: mm) Lighted/Non-lighted Pushbutton Switches (The following illustrations are for momentary operation.) Flat Type/-F For () Switches For (SPDT-NC) 27R 28 Alternate Operation Switches dia dia * For DPST-NO (DPST-NC) Monoblock-contact Switches dia * Half-guard Type/-H/L-H 18.5 Projection Type/-T/L-T 29.7 dia dia dia * * Full-guard Type/-G/L-G 40-dia. Mushroom Type/-M 29.7 dia dia * * Square/Projection type/-c/l-c Square/Full-guard Type/-D/L-D * * Note: Lighted models have the same dimensions as shown above, whether they are with or without Voltage Reduction Units. * Alternate operation models are 9.3 mm longer. 16
17 Dimensions (Unit: mm) Terminal Arrangement (Bottom View) Non-lighted ( + ) Lighted ( + ) Non-lighted (DPST-NO + DPST-NC) Switch Blocks M3.5 screw Switch Blocks Lamp socket Switch Blocks Terminal Connection Item Terminal connection BOTTOM VIEW Non-lighted ( + ) BOTTOM VIEW Non-lighted (DPST-NO + DPST-NC) BOTTOM VIEW Lighted without Voltage Reduction Unit ( + ) 1 X1 (+) X 3 2 X2 ( ) 4 BOTTOM VIEW Lighted with Voltage Reduction Unit ( + ) 1 X1 X 3 2 X2 4 Panel Cutouts dia dia. 0 Lock ring is provided as a standard item. When applying coating such as paint to the panel, the dimensions should be those after the application of coating. Recommended panel thickness: 1 to 5 mm. Use an Z-R25 Ring when mounting to a panel with 25-mm holes. 17
18 Dimensions (Unit: mm) Accessories Legend Plate Frames Standard Models Large dia. 28 dia dia. 28 dia ± 0.1 dia ± 0.1 dia Lamp LED Incandescent lamp -5, 12, ± max dia. 9.5 dia. 10±1 dia. Model indication BA9S/13 BA9S/13 Lock Ring Z dia. Ring Z-R dia dia. 22 dia dia. 27 dia Color Cap Z-30T@ Hole Plug (Round) Z dia Caps (for round models) Z M22 (for round models) Z dia dia dia dia dia dia dia. 18
19 Dimensions (Unit: mm) Sealing Caps For Flat Models Z-3600F For projection models Z-3600T For full-guard models Z-3600G 1R 32 dia. 32 dia. (26 dia.) R1 1R 31.5 dia. R dia. 33 dia dia. 33 dia dia dia. Metallic Bezel Rings For Flat/Projection Models Z dia. dia. 24± For full-guard models Z dia. dia. 24± M27 P=1 29.7± 0.3 dia. M27 P=1 29.7± 0.3 dia. Snap-in Legend Plates For Standard Models Z-3443@-@ For Large Models Z-3453@ For Emergency-stop Models Z (90 dia.) Z (60 dia.) Black letters E M R G E 90 dia. E M R G E 60 dia. E NCY Black letters E NCY Yellow t1 S T O P 22.2 dia. Yellow t1 S T O P 22.2 dia. Character Film For Round Models Z-3460-@ 17± ± For Square Models Z ± ± ± 0.2 t 0.22 t ±
20 Dimensions (Unit: mm) Lamp Extractor Z-3901 Tightening Wrench Z dia. 8.5 dia. 8 dia. 30 dia dia dia. 25 dia Cap Tightening Tool Z dia. Resin Attachment Z-A30 5 dia dia dia. Cap Puller A3PJ-5080 Lock Plate Z dia ± Simple Protective Cover Z-3700 Three-throw Spacer Z dia dia dia recess dia
21 Dimensions (Unit: mm) Control Box (Enclosure) Z-B101 (One Hole) Z-B101Y Four, M4 Phillips binding screws 22.1 dia. Cable Port Hole (Top View) Cover (*) Case (black) (10x36) 0.6-mm concave surface * Z-B101: gray Z-B101Y: yellow Two, 21 dia. (Lead cable hole) 16±1 dia. (Lead cable hole) Two mounting holes Z-B102 (Two Holes) Cable Port Hole (Top View) Four, M4 Phillips binding screws Two, 22.1 dia. Cover (gray) Case (black) (10x36) 0.6-mm concave surface 21 dia. (Lead cable hole) 16±1 dia (Lead cable hole) Two mounting holes Z-B103 (Three Holes) Four, M4 Phillips binding screws Three, 22.1 dia. Cover (gray) Cable Port Hole (Top View) Case (black) (10x36) 0.6-mm concave surface 21 dia. (Lead cable hole) 16±1 dia (Lead cable hole) Two mounting holes (Panel Mounting Hole) 3R
22 Dimensions (Unit: mm) Control Box Z-B201 (One Hole) Z-B201Y Four, M4 Phillips binding screws 22.1 dia. Cover (*) 21 dia. (both sides) Cable Port Hole (Top View) Two, 21 dia (10 36) 0.6-mm concave surface * Z-B201: gray Z-B201Y: yellow Case (black) Two, 19 dia. (base) 40 Two mounting holes Z-B202 (Two Holes) Cable Port Hole (Top View) Four, M4 Phillips binding screws Two, 22.1 dia. Cover (gray) 21 dia. (both sides) Two, 21 dia (10 36) 0.6-mm concave surface Case (black) Two, 19 dia. (base) Two mounting holes Z-B203 (Three Holes) Cable Port Hole (Top View) Four, M4 Phillips binding screws Three, 22.1 dia. Cover (gray) 21 dia. (both sides) (10 36) 0.6-mm concave surface Two, 21 dia. Case (black) Two, 19 dia. (base) Two mounting holes (Panel Mounting Hole) 3R
23 Safety Precautions Refer to Safety Precautions for All Pushbutton Switches/Indicators. WARNING Do not apply a voltage between the incandescent LED lamp and the terminal that is greater than the rated voltage. If the incandescent lamp is broken, the Operation Units may pop out. Always turn OFF the power and wait for 10 minutes before replacing the incandescent lamp. If the lamp is replaced immediately after the power is turned OFF, the remaining heat may cause burns. Precautions for Correct Use Mounting Do not perform wiring with power supplied to the Switch. Do not touch the terminals or other charged parts of the Switch while power is being supplied. Doing so may result in electric shock. Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Do not tighten the mounting ring more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting ring. The tightening torque is 0.98 to 1.96 N m. Recommended panel thickness: 1 to 5 mm. When mounting the caps after changing the LED or the caps, tighten the caps at a tightening torque of 0.49 tp 0.78 N m. Wiring Terminal screws must be Phillips or slotted M3.5 screws with a square washer. The tightening torque is 1.08 to 1.27 N m. Solid wires, stranded wires, and crimp terminals can be connected to the Switch. Applicable Wire Size Stranded wire: 2 mm 2 max. Solid wire: 1.6 dia. max. Bare Crimp Terminals 8 mm max. 8 mm max mm max mm max. Crimp Terminals with Insulating Sheath 8 mm max. 8 mm max. The LED current-limiting resistor is built-in, so internal resistance is not required. If commercially available LEDs are used, select the ones that meet the following conditions: Base: BA9S/13 Overall length: 26 mm max. Power consumption: 2.6 W max. When DC-specific LEDs are used, wire the Switch so that the X1 terminal is positive. Mis-lighting of the LED The LED lights with approx. 0.1 ma or less of micro-current. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED. The micro-current varies with the machine (leak current or stray capacity between cables, etc.). Select resistance value and allowable power consumption that meet the actual current. (Circuit example) In case of using 24 VAC/VDC, Direct lighting X1 LED lamp X2 R:10kΩ (1W) Bleeder resistor Others If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after the coating. Do not subject the Switch to extreme shock or vibration. Doing so will cause malfunctions and damage to the Switch. Using the Microload Insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60) (conforming to JIS C5003). The equation, λ 60 = 0.5 x 10 6 /operations indicates that the estimated malfunction rate is less than 1/2,000,000 operations with a reliability level of 60% mm max mm max. Voltage (V) ma 1.6 ma 100 ma After wiring the Switch, maintain an appropriate clearance and creepage distance. Operating Environment The IP65 model is designed with a degree of protection so that it will not sustain damage if it is subjected to water from any direction to the front of the panel. This switch is intended for indoor use only. Using the Switch outdoors will result in failure Invalid area 1 ma Microload area 10 ma Standard load area ,000 Current (ma) 23
24 Application Mounting to the Panel Panel Hole Dimensions Panel hole dimensions are given below. Recommended panel thickness: 1 to 5 mm. 22 dia R max. 25 dia. Matrix Installation 1. The following panel hole dimensions apply when Switch Unit and the Standard-size Legend Plate Frame and Lock Ring are mounted, and lead wires are connected directly to the Switch Block. 30 A Not Using a Lock Ring Using a Lock Ring For 25-dia. holes, always use 25-dia. Rings. (Since the cutout dimensions are large, IP65 cannot be guaranteed unless 25-dia. Rings are used.) If outer surface treatment such as coating is performed for the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions. 2. The following panel hole dimensions apply when the Large-size Legend Plate Frame is mounted, and when crimp terminals are connected to the Switch Block terminals. 30 B Pitches A and B between the centers of the mounting holes are as follows: For 1. above: Switch Blocks -10, -10S -01, -01S -20, -20S, S, -11, -11S For 2. above: Note: 1. The above dimensions are the minimum dimensions for when the wires described under Applicable Wire Size on page 23 are used. If a different wires are used, the wiring dimensions may be different so determine an appropriate pitch before setup. 2. With pushbuttons of external dimensions greater than 30 mm, set the pitch according to the dimensions. (When using matrix installation for the -M@, mount with a pitch of 40 mm instead of 30 mm in the diagram above.) Mounting the Operation Unit on the Panel Insert the Operation Unit (Pushbutton, etc.) from the front surface of the panel, insert the Lock Ring and the mounting nut from the terminal side, then tighten the nut. Before tightening, check that the rubber washer is present between the Pushbutton Unit and the panel. When using a Legend Plate Frame, put one rubber washer each between the Legend Plate Frame and the panel and between the Operation Unit and the Legend Plate Frame. (One rubber washer will be provided when one Legend Plate Frame is ordered.) Align the Lock Ring with the groove in the casing, then insert the Lock Ring so that its edge is located on the panel side. A 45 mm min. 55 mm min. Type of crimp terminal Switch Blocks B -10, -10S 51 mm min. -01, -01S Bare crimp terminals -20, -20S, mm min. -02S, -11, -11S Crimp terminals with insulating sheath -10, -10S -01, -01S -20, -20S, S, -11, -11S 60 mm min. 70 mm min. 24
25 Tighten the mounting nut at a torque of 0.98 to 1.96 N m. When using a Lock Ring, replace with the supplied Lock Ring, insert the projecting part into the lock slot, and then tighten the mounting nut. Mounting/Replacing the Color Cap Projection, Fall-guard Grip and rotate the Color Cap with your fingers. Hold here Rubber washer Mounting nut Panel Projecting part Lock Ring Panel When the panel cutout dimension is 25 dia., remove the supplied rubber washer and mount the 25-dia. Ring as shown below. (Since the Z-R25 is not attached to the main body, order separately.) Operation Unit Lock Ring Half-guard Indicators Put the tips of the Cap Tightening Tool (Z-3908) into the Color Cap slot and turn the Tool. 22 dia dia. 25 dia. 25-dia. Ring (Z-R25) Assembling the Cap Lighted Pushbutton Switch Mount the Color Cap so that the protrusions inside the cap fit into the grooves in the Pushbutton Unit. Panel 25 dia. Lock Ring 22.3 dia. Protrusion inside cap Mounting nut Mounting the Switch on the Pushbutton Unit Insert the Pushbutton Unit into the Switch Unit, aligning the arrow mark inscribed on the Case with the lever on the Switch Blocks, then move the lever in the direction indicated by the arrow in the following figure. Operation Unit Color Cap Indicator Mount the Color Cap so that the protrusions inside the Pushbutton Unit fit into the grooves in the cap. Arrow mark Lever Cap Removing the Switch Move the lever in the direction indicated by the arrow in the following figure, then pull the Pushbutton Unit or the Switch Blocks. Since the lever has a hole with an inside diameter of 6.5 mm, the lever can be moved in the specified direction by inserting a screwdriver into the hole and then moving the screwdriver. Screwdriver Protrusion Grooves Color Cap 25
26 Square Pushbutton/Indicator Square Pushbutton/Indicator Insert the protruding tip of the Cap Puller (A3PJ-5080) into the Cap slot, hold the plate spring, and pull them to remove the Color Cap. Installing/Replacing the Lamp Installing/Replacing from the Panel Surface Insert the Lamp Extractor (Z-3901) into the lamp, then rotate the Extractor while pressing it. Plate spring Mounting the Color Cap: Mount the Color Cap on the flange and firmly push the Color Cap. When the Color Cap is inserted, check whether it operates properly. When replacing the Lamp, remove the Color Cap and diffusion plate with fingers or Cap Puller. Attach the Character Film properly so that it fits inside the protruding part of the diffusion plate. Then, match the diffusion plate to the square flange and insert the Cap. Flange Installing/Replacing on the Switch Grip the lamp with your fingers, then rotate the lamp while pressing it against the Switch. Diffusion plate Character Film Color Cap Emergency Stop Switch Insert the protrusion of the Tightening Wrench (Z-3905) into the Cap slot and then turn to remove the Cap. Control Box (Enclosure) Mounting the Switch The Standard-size Legend Plate Frame can be mounted. Mount the Frame as shown in the following diagram. Mount the Switch in the same way as for an ordinary panel. Snap-in Legend Plate Creating a Cable Port Hole Place the tip of a screwdriver on the surface where the cable port hole is to be created with the cover attached and strike the screwdriver with a hammer to punch four holes. Screwdriver Side Switch box Cover Cable port hole Make four holes in diagonal lines. Groove 26
27 Securing the Connector Cable 1. Insert the connector into the cable port hole in the Box and secure with the fixing nut inside the box. 2. Open a hole in the thin rubber section of the rubber ring. 3. Pass the tightening cap through the cable, insert the cable into the connector, and tighten the hexagonal nut to secure the cable. Cable diameter Connector 7 to 9 dia. Z to 11 dia. Z Removing the Switch Blocks Insert a screwdriver between the Mounting Latch and the Switch Block, then push down the screwdriver in the direction indicated by the arrow in the following figure. Use either of the following screwdrivers. Flat-head 3 to 6 mm screwdriver Phillips screwdriver 3 to 6 mm Fixing nut Rubber washer Connector Tightening cap Cable Screwdriver Inside Outside Box Switch Blocks Installing the Switch Blocks Hook the small protrusion on the Switch Block into the groove on the Mounting Latch on the other side of the lever, then push up the Switch Block in the direction indicated by the arrow in the figure below. Mounting Latch Lever Wiring Wiring Round Crimp Terminals Loosen the terminal screw from the Switch Unit until it completely comes off the groove, insert a screwdriver as shown in the following figure, then push up the washer in the direction indicated by the arrow to temporarily secure it. Now, a round crimp terminal can be connected. After inserting the terminal, tighten the screws to complete wiring. Washer Screw Screwdriver Switch Block Protrusion Engraving Engrave the characters on the surface on the Cap. Make sure that the characters are aligned parallel to the imaginary line connecting the two protruding portions to the left and right of the Cap. The characters must not be engraved deeper than 0.5 mm. Apply an alcohol-based paint coating, such as melamine, alkyd, or acrylic resin paint coating, to the engraved characters. Protruding portions on Cap 27
28 Affixing Character Film Hold the Cap, remove the cardboard on the Film, and attach the Film to the Cap. Make sure that the protruding portions of the Cap engage he cutout portions of the Film and that the characters are aligned parallel to the imaginary line connecting the two protruding portions to the left and right of the Cap. The Snap-in Legend Plate is easily removed by pressing the Snapin Legend Plate from the back of the Legend Plate Frame. The Legend Plate Frame is made of acrylic resin, which is easily damaged by shock. Be sure to handle the Legend Plate Frame with care. Remove the cardboard. Protruding portions on Cap Mounting and Dismounting Snap-in Legend Press and secure the Snap-in Legend Plate onto the Legend Plate Frame. The direction of the characters will vary with the mounting direction of the control panel if the Switch is a knob or key selector model. Legend Plate Frame Snap-in Legend Plate Concave surface To easily remove the Snap-in Legend Plate from the Legend Plate Frame mounted to the panel, insert a Tool with a thin tip into the space between the Snap-in Legend Plate and the Legend Plate Frame. Engraving Method Material: Acrylic Engrave the characters directly on the matted side of the Snap-in Legend Plate. The characters must be engraved no deeper than 0.5 mm. Apply alcohol-based paint coating to the engraved characters. If the Snap-in Legend Plate is transparent, engrave the mirrorwritten characters on the back of the Snap-in Legend Plate and apply paint coating to the characters. Then apply paint coating of a different color to the remaining part of the Snap-in Legend Plate. Mounting Three-throw Spacer Press and secure the two protruding portions of the Three-throw Spacer to the two indented portions of the inner side of the control panel. 28
29 Mounting the 30-dia. Resin Attachment Pushbutton Rubber washer (Operation Unit mounting part) Attachment Rubber washer (included) Mounting panel Lock Ring Mounting nut 29
30 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2013 All Right Reserved.
VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.
General-purpose Limit Switch CSM DS_E_3_ Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure
EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
Ordering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control
Latching Relay CSM DS_E_4_1 Magnetic Latching Version of G2A Ideal for Sequence Control Double-winding latch system with continuous rating. Terminals pulled from the respective junctions between the built-in
Pushbutton Switch / Indicator
Pushbutton Switch / Indicator Mounting Aperture of 16 mm Modular construction (Pushbutton + Case + Lamp + Switch Unit) Wide Variety of Control and Signal Devices: Lighted, Non-Lighted, and Buzzer (Refer
D2SW-P. Sealed Subminiature Basic Switch. Ordering Information
Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.
Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact
Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
Capacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement
Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
INDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA 01835-0788 TOLL FREE: (877) 246-7890 FAX: (781) 245-4531 E-mail: info@apem.
INDUSTRIAL CONTROLS INDUSTRIAL CONTROLS E INDUSTRIAL CONTROLS SELECTION GUIDE Series Description Page A01 & A02 Products & Features 2 A01 & A02 Specifications 3 A01 Illuminated or non-illuminated pushbutton
Smile 11 AS-i Emergency stop with safe AS-i input node
Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Ordering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
Ordering Information. Specifications. Electrode Holder PS-@S(R)/-31. Electrode Holders. Accessories (Order Separately)
Holder PS-@S(R)/-31 Separate Holders for Water Supply and Drainage Control in Buildings. Small, Lightweight Holders for Use as Built-in Components. The PS-@S(R) are separate Holders that allow the s to
Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
Knob Potentiometer with Switch
Knob Potentiometer with Switch The is a revolutionary concept in panel mounted potentiometers. This unique design consists of a knob driving and incorporating a cermet potentiometer. Only the mounting
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Model Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
Model Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
Q SERIES Ø14mm (.551") Panel Mount LED Indicators Distinctive features and specification
Distinctive features and specification Q14_VOY1609R2US Features 14mm panel mounting LED indicator 10mm colored diffused epoxy lens or 10mm water clear super bright LEDs Plated brass bezel finished in bright
Knob Potentiometer FEATURES. P16NP P16NM Panel Cutout. Thickness nut 2 mm washer 1.5 mm. Panel sealing ring 12 wrench Thread M10 x 0.75 10.2 9.
Knob Potentiometer P6, PA6 FEATURES Test according to CECC 4000 or IEC 60393- P6 - Version for professional and industrial applications (cermet) W at 40 C PA6 - Version for professional audio applications
Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2
R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360
Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_ Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120
Solid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : [email protected] Solid-State Timer Low-Cost, Plug-In
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm
Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test
Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Control and Signaling Units
Control and Signaling Table of Contents Page Specifications... 3 Constructions Characterisitics... 3 Ordering Guide... 4 Pushbutton... 5 Double Pushbutton... 6 Emergency (Mushroom Head)... 6 Selector...
U-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E
PCB Power elay The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
Tina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
Surface Mounting Relay
Surface Mounting Relay Surface Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density
STC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Switches and Indicators. Swisstac
Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons
PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- ---
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE045 (VDE approval: C2 insulation grade), UL8, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small
EQ-00 VF NX MS-AJ RT-0 PX- CY PHOTOELECTRIC SENSORS Mounting Stand SERIES U-shaped Micro Photoelectric PNP output type available Extremely small Ultra-small type -4(-R) contributes to the miniaturization
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.
y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long
Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE
POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.
Switches & Pilot Devices
Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
OPLC Installation Guide
Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital
Solid State Relays for Heaters
New Product Solid State Relays for Heaters Single-phase G3PE Compact, Slim-profile SSRs with Heat Sinks. Models with No Zero Cross for a Wide Range of Applications. RoHS compliant. Models also available
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.
2010-2011 Solutions for appliance & electronic applications Shortform Catalogue rocker lever push vandal resistant slide door snap-action & safety rotary IEC sockets fuseholders indicators A trading name
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
TECHNICAL INFORMATION
TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier
Waterproof Connectors for Outdoor Use
Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight
Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA
Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA Ideal for 3-phase voltage asymmetry monitoring for industrial facilities and equipment. Monitor voltage asymmetry, phase sequence, and
Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer
5000020G Warning Before Installation English Power off the Network Camera as soon as smoke or unusual odors are detected. Do not place the Network Camera on unsteady surfaces. Do not insert sharp or tiny
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
SPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to
Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1
Power PCB Relay G2R Creepage distance of 8.0 mm (0.31) min. between coil and contact. Dual-winding latching type available. Plug-in and quick-connect terminals available. High sensitivity (360 mw) and
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
Machine Automation Controller NJ-series. Startup Guide. for Motion Control W514-E1-01
Machine Automation Controller NJ-series Startup Guide for Motion Control W514-E1-01 OMRON, 2011 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Radiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
