Design and Construction of Degassing Units for Catfish Hatcheries
|
|
|
- Grace Brown
- 10 years ago
- Views:
Transcription
1 SRAC Publication No. 191 March 1999 PR VI Design and Construction of Degassing Units for Catfish Hatcheries John A. Hargreaves and Craig S. Tucker* In some catfish or baitfish hatcheries, water in egg-hatching or fry-rearing tanks may have a condition called gas supersaturation that is harmful to fish. Gas supersaturation means that the water contains more gas at a certain air (barometric) pressure and water temperature than would normally occur if the water was allowed to come to equilibrium with the atmosphere. Fish living in such waters may develop a stressful or lethal condition called gas bubble trauma. Gas supersaturation can occur frequently in hatcheries, and small fish confined in shallow tanks are especially susceptible to gas bubble trauma. Because the diffusion of excess gas out of water can be slow, water often must be treated before it is used in a hatchery. Gas supersaturation problems may be difficult to diagnose, but are easily remedied with simple, inexpensive equipment such as the packed-column aerator described here. gases dissolved in water. The total amount of gas dissolved in water is commonly expressed as the difference between the sum of the pressure of all gases in water and the sum of the pressure of those same gases in the air (described by the term P, which is read as delta P ). It also can be expressed as the percent saturation of the gases in water. Total dissolved gas pressure, barometric pressure, and P can be expressed in any of the units commonly used to express air pressure, such as millimeters of mercury (mm Hg) or inches of mercury (in Hg). When the partial pressure of a gas in water is equal to the partial pressure of that gas in air ( P i =0), then that particular gas in the water is at equilibrium with the concentration of the gas in the atmosphere and there is no net movement of that gas either into or out of the water. If the partial pressure of a gas in water is less than the partial pressure of that gas in air ( P i is less than 0), then water is undersaturated with that particular gas and it will diffuse into the water. If the partial pressure of a gas in water is greater than the partial pressure of that gas in air ( P i is greater than 0), then water is supersaturated with that particular gas and it will diffuse out of the water to the atmosphere. It is possible for the total gas pressure in water to exceed barometric pressure ( P is greater than 0) while a particular gas is undersaturated. Total dissolved gas pressure (TGP) is sometimes reported as a percentage of local barometric pressure. At saturation, TGP percent = 100 percent; when waters are undersaturated, TGP percent is less than 100 percent; and if the water is supersaturated, TGP percent is greater than 100 percent. Definitions Nitrogen, oxygen, carbon dioxide, and other atmospheric gases are dissolved to some extent in water. Total dissolved gas pressure is the sum of the partial pressures of all Table 1. Ways of expressing gas supersaturation. P TGP Direction of Condition (mm Hg) (%) gas diffusion Undersaturated <0 <100 from air into water Saturated (equilibrium) no net diffusion Supersaturated >0 >100 from water into air *Mississippi State University
2 Effect of supersaturation on fish The effect of adding supersaturated water to a hatchery trough or fish tank is similar to opening a soft drink bottle. The pressure that held gases dissolved in water is now released and the gases will form bubbles and diffuse into the atmosphere. If fish are exposed to this water, the gas will diffuse across the gills into the fish. Bubbles can form in the gills, fins, skin and blood. Bubbles in the blood can block circulation and cause serious or fatal injury, particularly to fry or young fish. Some of the symptoms of gas supersaturation include popeye or hemorrhaging around the eyes, distended stomachs, coagulated yolk in yolk-sac fry, and more importantly, secondary bacterial or fungal infections related to stress. Catfish fry affected by gas supersaturation often become trapped upside down at the surface because bubbles form in the yolk sac. Identifying gas supersaturation problems Most problems with supersaturation are first identified when there are unexplained chronic or acute losses of fry in the hatchery. Sometimes the fry will exhibit some characteristic symptom, such as floating upside down or bubbles in the eyes, skin or fins. However, these clinical signs can appear and then disappear rapidly. Often there will be no obvious symptom at all. Gas supersaturation can be suspected if tiny bubbles form on the insides of the hatchery tanks. Running your hand over the inside of a tank will release a swarm of these small bubbles and make them easier to see. The P of a hatchery water supply can be measured with a saturometer. Most hatchery managers do not have this rather specialized and expensive piece of equipment, and it is not an essential tool. Some government fisheries biologists or university researchers have access to a saturometer, so if you suspect a problem, you may be able to find someone who can visit the hatchery and make the measurement to confirm whether or not a problem exists. Note, however, that the severity of a gas supersaturation problem in a hatchery can change over time, sometimes suddenly, depending upon the water pumping rate and the condition of the plumbing in the hatchery. Fry should be observed vigilantly for potential gas bubble problems. Sources of gas supersaturation If you determine that the water in hatchery rearing tanks is supersaturated, it is important to identify the source of the supersaturated water. The most effective approach to solving the problem depends on the origin of the gas. The water source itself may be supersaturated, or the water may become supersaturated as it is pumped to the hatchery. Supersaturation is usually not a problem in good quality surface waters, although other problems with using surface waters in hatcheries outweigh that small advantage (see SRAC Publication 461). Surface waters with dense growths of aquatic plants or algae can become supersaturated with dissolved oxygen on bright, sunny afternoons. Most catfish hatcheries use deep groundwaters because the supply is consistently of high quality. from deep wells is warmed by the heat of the earth, making it unnecessary to heat the water to the optimum temperature for egg and fry incubation. However, groundwater often is supersaturated with dissolved gases. If that is the case, and there is no alternative water source for the hatchery, the water can be degassed and aerated in a packed-column aerator as described below. Although not a common problem, especially when wells are properly constructed, waters can become supersaturated if air is sucked into the water supply when the well surges. Surging occurs when sands dislodged during well drilling partially clog the screen or strainer at the bottom of the well casing. This impedes the flow of water into the casing, which results in water being pumped out of the well faster than it flows into the casing from the aquifer. When the water level inside the casing drops below the bottom of the intake pipe strainer, air is sucked into the line and gases are forced into solution as water passes through the pump. This problem is most common in new wells and usually corrects itself as the well is used. If surging persists, inform the person who drilled the well. Screens of older wells in areas with hard, alkaline groundwaters may become clogged by encrustations of lime or iron oxide. Cleaning with muriatic (dilute hydrochloric) acid will correct this problem and most well-drillers do this routinely. Regardless of the water source and whether or not it starts out supersaturated, faulty plumbing of the water supply lines to the hatchery can cause it to become supersaturated (or more supersaturated). This occurs when air is sucked into the water through small, pin-hole leaks in the plumbing fittings and pipes on the suction side of pumps. As the entrained air passes through the pump, it is pressurized and some of the gases are driven into solution. More gas entrainment can occur on the pressure (outlet) side of a pump, particularly across a partially-open, true-union, PVC ball valve. Problems caused by faulty plumbing can sometimes be remedied by finding the leak and repairing the line, although it is best to avoid or prevent the problem in the first place. When constructing the hatchery, pay particular attention to proper application of adhesives at plumbing joints and fittings. Clean fittings carefully with an approved solvent and generously apply adhesive to both pipe and fitting before joining with a quarter twist of pipe against fitting. Apply teflon tape or pipe compound liberally to the threads of reducer bushings or other threaded fittings, particularly at the pump inlet and outlet.
3 When catfish hatcheries are supplied with water from a well, diagnosing the source of the supersaturation is usually not difficult because most groundwaters in the Southeast do not contain dissolved oxygen. If the water flowing into the hatchery contains no dissolved oxygen but is nevertheless supersaturated with gas, the groundwater itself probably is supersaturated or has become supersaturated when heated in a closed boiler. If, however, the water flowing into the hatchery contains some dissolved oxygen (often just 1 or 2 mg/l), that means that the water has contacted air at some point and the problem is caused by an air leak in the plumbing or a surging well. Quite often, air bubbles entrained in the water by these two processes makes a hissing sound as the water travels along the piping. This sound is often most noticeable at elbows or T fittings. Problems caused by an air leak in the plumbing can be differentiated from those caused by a surging well by turning the well off for an hour or two, and then turning it on while measuring the dissolved oxygen concentration of the water as it flows into the hatchery. If the problem is caused by an air leak in the supply line, dissolved oxygen will be detected in the water almost immediately after the well is turned on. If the problem is caused by a surging well, the water will not contain dissolved oxygen at first because anaerobic groundwater is being pumped into the hatchery. If, after some period of pumping, the water level inside the casing falls below the intake and air is sucked in, the dissolved oxygen level in the water will suddenly begin to rise, indicating a surging well. The time interval between turning the well on and the first surging depends on the well pumping capacity and the degree to which the screen is clogged; it can range from a few minutes to several hours. s also can become supersaturated when heated in a closed boiler where excess gases can not escape completely. This occurs because the solubility of gases decreases with increasing temperature, so if gases cannot escape when water is heated, the water will be supersaturated at the final temperature. This occurs often in hatcheries that use cool groundwaters or surface waters early in the spring spawning season. Heating water from 20 o C (68 o F) to 26 o C (80 o F) in a closed boiler can cause an increase in P sufficient to cause chronic gas bubble trauma in channel catfish sac-fry. Packed column design Some problems with gas supersaturation can be avoided by properly plumbing the water supply line to the hatchery and by using good well drilling and maintenance practices. flowing into hatchery tanks can be partially degassed by vigorously aerating the holding tank with a number of diffusers or with an agitator, although these techniques are not very efficient and not completely effective. can also be degassed somewhat by breaking the flow into a fine spray with a common garden-hose spray nozzle and spraying water into the hatching or rearing tank. However, one of the simplest and most effective ways to manage gas supersaturation problems is to use packed-column aerators. Packed columns serve two roles, depending upon the quality of incoming water. If the water is supersaturated with dissolved gases, then a properly designed and constructed packed column will relieve the supersaturated condition. If the dissolved oxygen concentration of the water is low, and usually dissolved oxygen is absent in groundwater, then a properly designed and constructed packed column will also saturate the water with dissolved oxygen. A packed column consists of a vertical vessel filled with packing medium. The medium should have a large (about 90 percent) void or empty space per unit volume and should pack in a way that allows the water flow to break up randomly into a thin film that trickles down through the column, following a very circuitous pathway. Various packing media are sold under the names ballast rings, Bio-barrels, Actifil pall rings, Tri-pack spheres, and Nor-Pac. A perforated support holds the medium in at the bottom of the column. Near the top of the column, a water distribution with many holes is placed over the packing medium. The height of the packing is an important design variable of a packed column. Packing height is based on a number of design criteria and will depend upon the characteristics of the incoming water. Two cases are presented below to illustrate how to configure the packed column. In the first case, assume that the water contains no dissolved oxygen but is not supersaturated. The packed column will be used only as an aerator and Figure 1 can be used to estimate the height of the packed column required to provide the desired dissolved oxygen concentration at the outlet. To use Figure 1. Pall rings of various sizes can be used as media in packed columns.
4 Figure 2. Packed column height required to result in various outlet water dissolved oxygen concentrations at a range of water temperatures. Area within dashed lines indicates the optimum temperatures for channel catfish egg incubation. the figure for design purposes, begin by selecting the water temperature. Extend a vertical line up to the desired dissolved oxygen concentration. Then, extend another line horizontally to the left, at a right angle to the first line, to select the packing height. For example, if the temperature of a catfish hatchery water supply is between the optimum of 78 and 82 o F and the desired dissolved oxygen concentration of the water flowing out of the packed column is 90 percent of saturation (between 7.0 and 7.3 mg/l), then a packing height of 3.5 to 4 feet is necessary. As water temperature increases, the packing height required to achieve a given dissolved oxygen concentration increases, although the packing height required to achieve 90 percent saturation is not affected by temperature and stays at about 3 feet 8 inches. In the second case, assume that the water is supersaturated with dissolved gases. Use Figure 2 to estimate the required packing height for the desired gas pressure differential ( P) between the outlet water and the atmosphere. Most hatchery waters should have a P between 10 and 20 mm Hg and should not exceed 40 mm Hg. From the figure, it can be seen that as the P of the incoming water increases, the packing height required to produce a given P of the outlet water increases. The lower the desired P of the outlet water, the greater the packing height required. The vertical dashed line on the figure provides a point of reference by indicating the average P of well water from 27 catfish hatcheries in the Mississippi Delta. But remember, the P of well waters can change through time and may suddenly become a severe problem. To use the figure for design purposes, begin by selecting the P of the incoming water. Extend a vertical line up to the desired outlet P. Then, extend another line horizontally to the left at right angles to the first line to select the packing height. As an example, if the P of incoming well water is about average for catfish hatcheries in the Mississippi Delta, and the desired outlet P is about 10 Table 2. Guidelines for selecting packed column diameter, size of medium, and air flow rate based on water flow rates. Recommended Maximum Column Squirrelcage flow rate flow rate diameter Media size Air flow rate blower size (gpm) (gpm) (inches) (inches) (cfm) (amps)
5 Figure 3. Packed column height required to result in various outlet water gas pressure differentials as a function of incoming water gas pressure differential. Dashed line indicates average gas pressure differential in groundwaters used in catfish hatcheries in the Mississippi Delta. mm Hg, then the required packing height is 4 to 4.5 feet. Such a column height will also achieve at least 90 percent saturation of water with dissolved oxygen. In both design cases, an additional 1.5 to 2 feet should be added to the column height to accommodate inlet and outlet plumbing adjacent to water distribution and media support s. The required diameter of a packed column will depend on water flow rate (Table 2). Flow rates to packed columns range from 40 to 100 gpm/ft 2 of column cross-sectional area. Table 2 offers some guidelines on the selection of appropriate column diameters. Most catfish hatcheries require a water flow of 100 to 150 gpm, and so will require columns 12 to 18 inches in diameter. Flow rate should not exceed the design maximum, as this will flood the column and prevent degassing. Also avoid using columns with diameters smaller than 6 inches because of potential problems with short-circuiting water flow down column walls. One of the most important, and often neglected, design parameters of packed columns is air flow rate. Good air flow is essential for effective performance. Air flow provides oxygen and strips away undesirable dissolved gases such as carbon dioxide, hydrogen sulfide and methane. If the top and bottom of the column are open to the air, then air flow through the column should be sufficient to degas the water. In such a case, add 2 additional feet to the packing depth as determined by Figures 2 and 3. However, if the bottom of a packed column is placed in a sump or is sealed, then forced-air ventilation is necessary. The principal behind a packed column is to break water up into thin layers, across which gas can transfer efficiently. This process is enhanced by passing a relatively large volume of air through the column in the opposite direction (counter current) to the water flow. At least 2 to 3 unit volumes of air should be added to the column for each unit volume of water (Table 2). Squirrel-cage blowers or regenerative blowers can be used for this purpose, but squirrel-cage blowers are a better choice because they are designed to deliver air against a very low pressure gradient, typical of packed columns, whereas regenerative blowers are designed to move air against a fairly low head pressure of water (typically 24 to 48 inches). Counter current air flow requires that the lower end of the packed column be sealed or submerged in a water collection sump or else the air will flow out of the column in the same direction as the water. It also requires an air ventilation riser pipe through the water distribution near the top of the column. Packed column construction Once column height, column diameter, medium size and blower size have been selected, the packed column can be constructed. Columns are generally cylindrical in shape; therefore, PVC pipe, concrete culverts, and lined grain silo rings are suitable materials for construction. Materials less than 1 /8 inch thick can be used for packed columns. Packed columns can be integrated with water supply head tanks or built as stand-alone units. The advantage of integrating the packed column with an exterior head tank is that water flow to the hatchery can be regulated by the head pressure of water in the tank. However, water must then be pumped to some relatively small additional head to account for the packed column height.
6 distribution Medium support Head tank Support tower distribution Packing material Medium support Sump Slots distribution Packing material Medium support Open top Packing medium Open top line to hatchery (by gravity) supply line (from well) Air vent riser pipe (to outside) supply line from well Squirrel cage tower line to tanks pump Air vent riser pipe (to outside) supply line from well Squirrel cage blower line to tanks (by gravity) Column support structure Figure 4. Components and suggested configurations of packed columns for channel catfish hatcheries. Ventilation of packed columns integrated with head tanks is probably not necessary, as the top and bottom of the column are open. The major disadvantage of integrating a packed column with a head tank is the relatively large heat loss that may occur across the packed column, particularly when operated early in the hatchery season. A large heat loss as water passes through the packed column might necessitate reheating the water in a boiler, which may defeat the purpose of using the packed column because heating the water may itself cause supersaturation. Stand-alone units can be placed within the hatchery building, but this configuration may require that water be pumped a second time, usually from a collection sump placed at the base of the column. If a packed column is placed within a water collection sump, then the column must be mounted in such a way that the packing medium is not flooded. This can be accomplished by physically mounting the column above the water level or, if the base of the column rests on the sump bottom, by placing the medium retention at a height in the column above the water level of the sump. When a stand-alone packed column is placed within a hatchery the building must be ventilated or the air flow from the column vented to the outside so that carbon dioxide and other harmful gases will not accumulate. To construct a packed column, first suspend the medium support in the column. If the column is a stand-alone unit, locate the support at least 3 to 6 inches above the water level of the collection sump. Vinyl-coated hardware cloth or perforated aluminum sheet metal are suitable materials for support construction. The support in larger diameter columns may be supported by extending re-enforcing rods ( re-bar ) or other rolling stock through the column and sealing the holes with silicone caulk. Or, blocks or a ring for holding the support can be attached to the inner diameter of the column. Next, cut a square hole, corresponding to the outlet from the squirrel-cage blower, near the lower end of the column. The blower should be mounted well above the water level of the sump to minimize the potential for electrical shock and flooding of the blower motor. The blower can be mounted on the column just before installation or right after the column is installed. Construct the water distribution and place it about 6 to 9 inches from the top of the column. This allows space for water to splash before passing through the. The water distribution does not need to be as rigid as the medium support, although it should be about 3 /16 inch thick. Suitable materials include perforated aluminum sheet metal, plexiglass, or fiberglass-reinforced plastic. The support should be drilled with holes, as suggested in Table 3, with a hole in the center large enough for a riser pipe (2- to 4-inch ID depending upon column diameter) that vents the air introduced by the blower at the bottom of the column. If flow rate is expected to vary predictably (for example, increasing during the hatchery season), then multiple and interchangeable water distribution s can be fabricated. Before placing the water distribution in the column, add the packing medium. Add small amounts at a time and shake the column or use a stick or piece of pipe to stir the medium so it will pack well. Once the medium is packed into the column, place the water distribution on the support structure. Sealing the support to the column wall with a bead of caulk helps direct water flow through the column rather than down the wall. The inflow pipe can be placed over the top of the distribution, or water can be introduced from the side, through the wall of
7 Table 3. Guidelines for constructing a water distribution for a packed column of a given diameter. Column Air vent Hole Number of holes Number of holes diameter riser pipe diameter diameter at at (inches) (inches) (inches) recommended flow rate maximum flow rate 8 2 1/ / / / / / / the packed column. The top of the column can be open or fitted with a cover that can also hold the water supply plumbing in place. A packed column requires very little regular maintenance. Many groundwaters contain fairly high concentrations of dissolved iron, which can oxidize and settle out on the medium as a rust-colored solid. It is highly unlikely that enough oxidized iron will settle out to clog the medium. Rust-colored solids passing through the packed column can be removed by directing the water flow through a settling tank, gravel bed, or sand filter. It is good practice to inspect the column between hatchery seasons and, if necessary, remove the medium and dislodge any accumulated solids with highpressure water. The medium also can be removed and placed in a solution of muriatic acid for cleaning, but should be thoroughly rinsed with fresh water before it is used again. Acknowledgments John Colt and Barnaby Watten provided helpful suggestions for this fact sheet. References Bouck, G.R., R.E. King and G. Bouck- Schmidt Comparative removal of gas supersaturation by plunges, screens, and packed columns. Aquacultural Engineering 3: Colt, J. and G. Bouck Design of packed columns for degassing. Aquacultural Engineering 3: Hackney, G.E. and J.E. Colt The performance and design of packed column aeration systems for aquaculture. Aquacultural Engineering 1: Marking, L.L., V.K. Dawson and J.R. Crowther Comparison of column aerators and a vacuum degasser for treating supersaturated culture water. Progressive Fish- Culturist 45: Tucker, C.S. quantity and quality requirements for channel catfish hatcheries. Southern Regional Aquaculture Center Publication 461. Weitkamp, D.E. and M. Katz A review of dissolved gas supersaturation literature. Transactions of the American Fisheries Society 109:
8 The work reported in this publication was supported in part by the Southern Regional Aquaculture Center through Grant No from the United States Department of Agriculture, Cooperative States Research, Education, and Extension Service.
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Anode Rods, Cathodic Protection and the Porcelain (glass) Lining
Corrosion can be defined as the destructive attack of a metal by an electrochemical reaction with its environment. Steel exposed to moisture and oxygen will rust and corrode. Corrosion is defined as the
Treatment options for hydrogen sulfide. Testing for hydrogen sulfide
Sometimes hot water will have a sour smell, similar to that of an old damp rag. This smell often develops when the thermostat has been lowered to save energy or reduce the potential for scalding. Odor-causing
Septic Tank to Cistern Conversions. Saving Water & Saving Money
Florida Keys Aqueduct Authority 1100 Kennedy Drive Key West, Florida 33040 Septic Tank to Cistern Conversions Saving Water & Saving Money One of the benefits of connecting to the Central Wastewater System
ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10
Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters When water is heated, it naturally expands and allowance has to be made for this. Vented water heaters usually
Fiberstars Lighted Laminar Flow Fountain Installation Manual
Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation
VACUUM REFRIGERATION SYSTEMS
VACUUM REFRIGERATION SYSTEMS CHILL VACTOR The Croll-Reynolds CHILL-VACTOR is a chiller that uses a vapor flashing process. Water has a pressure-temperature relationship which is its boiling point. If its
HS-901(A) BASIC STEAM HEATING SYSTEMS
HS-901(A) BASIC HEATING SYSTEMS One-Pipe Two-Pipe Basic Steam Heating Systems One-pipe steam heating system EQUALIZER SAFETY FACTOR STATIC HEAD PRESSURE DROP 2" HEATING UNIT 15" DRIP CONNECTION In a one-pipe,
Carbon Dioxide in Fish Ponds
SRAC Publication No. 468 Southern Regional Aquaculture Center April 1996 PR VI Carbon Dioxide in Fish Ponds John Hargreaves and Martin Brunson* * Mississippi State University A pond breathes in and out
In-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
Corrosivity of Water Supplies
WD-DWGB-3-4 2009 Corrosivity of Water Supplies What is meant by Corrosivity? Corrosive water can be defined as a condition of water quality which will dissolve metals from metallic plumbing at an excessive
Why is my air conditioner dripping on my customers?
De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These
5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved.
8 90 2010 PulteGroup, Inc. All Rights Reserved. drains All the water you use leaves the home through a drain. Maintaining drains prevents clogging, overflows, water damage, and other problems. care and
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE
1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.
Liquid Distributors. Liquid Redistribution. Liquid Distribution. INTALOX Distributors
Liquid Distributors Liquid Distribution Liquid distributors are used above each bed of packing in a packed column to provide uniform liquid distribution. The distributor, depending on its design features,
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems What every homeowner should know about living with a well and a private sewage system. YOUR ENVIRONMENTAL SYSTEMS Out of sight out of
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
A Guide to Trouble-Free Cooling Towers
A Guide to Trouble-Free Cooling Towers A basic understanding of cooling tower operation and maintenance will help keep a cooling water system running in top condition, year after year By David M. Suptic
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
CHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
Design of Closed-loop Fumigation Systems for Grain Storage Structures
Oklahoma Cooperative Extension Service BAE-1111 Design of Closed-loop Fumigation Systems for Grain Storage Structures Carol Jones Assistant Professor, Stored Products Engineering James Hardin Research
PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques
PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques Introduction The amount of dissolved oxygen in process water is continually gaining importance in many industries as a critical parameter
Iron Air Charge 2510-SXT Installation & Start-Up Guide
Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water
GENERAL RUBBER LINING PRINCIPLES
GENERAL RUBBER LINING PRINCIPLES I. METAL PREREQUISITES Metal to be lined should meet the requirements as stated in section 8 Metal Fabrication and section 12 Blasting and Cementing Procedures. The surface
DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS
DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS Phase I MS4 permits require continuous updating of the stormwater system inventory owned and operated by the MS4. They also include inspection
Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities
Fats, Oil and Grease Best Management Practices Manual Information, Pollution Prevention, and Compliance Information For Food Service Facilities Pinellas County Utilities Water Quality Management Division
Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007
Service Guide Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines ORDER No: UN-SVG001A-EN DATE: October 9, 2007 Introduction This document defines American Standard and Trane s recommendations
I. STEAM GENERATION, BOILER TYPES
I. STEAM GENERATION, BOILER TYPES and BOILER PLANT SYSTEMS 1 Steam Generation Water s Unique Properties: High Thermal Capacity (Specific Heat) High Critical Temperature Ideal Medium for Heat Delivery High
Most agencies think about cleaning because of debris in the line.
Most agencies think about cleaning because of debris in the line. If we have an effective cleaning program there should not be a lot of debris in the line after the line is cleaned and tv d for acceptance.
Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5
PROTECTIVE PLUMBING - WHAT IS IT? TABLE OF CONTENTS Protective Plumbing What is it?...page 1 What is Foundation Drainage?...Page 2 What is a Sump Pumping System?...Page 4 Does Part of My Basement Floor
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service
Experts Review of Aerobic Treatment Unit Operation and Maintenance Bruce Lesikar Texas AgriLife Extension Service Overview Overview of Aerobic Treatment Units Installing for accessibility to system components
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
Learning Objectives. History of Vacuum Testing for Precast. Vacuum Testing. Terminology and purpose
: It Just Sucks! Presented by: Darryl Cloud Concrete Sealants, Inc. Learning Objectives In this course, you will learn: Terminology for Watertightness Equipment Tips, Tricks, and FAQ s History of Vacuum
MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM
MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM Maintenance is critical to the efficient performance of the CLEAN-FLO system. These maintenance activities
Septic Tank Use & Maintenance Tips
Yellowhead County Hamlet of Cadomin Septic Tank Use & Maintenance Tips This guide gives an overview of the responsibilities for property owners in Cadomin. For Seasonal, Permanent & Vacationing Cadomin
PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:
PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name
Iron and Manganese BACTERIA AND IRON AND MANGANESE
Iron and Manganese Iron and manganese control is the most common type of municipal water treatment in Minnesota. Iron and manganese occur naturally in groundwater. Neither element causes adverse heath
Fiberstars Mini Lighted Laminar Flow Fountains
Fiberstars Mini Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Mini Lighted Laminar Flow Fountain. The
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L AT I O N I N S T R U C T I O N S C A R E F U L LY CAR
CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION
CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION Grease, So What's the Problem? Does your facility produce grease? All commercial cooking facilities generate Fats, Oil, and Grease
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing
Power Cube Open Source Ecology Page 1. Power Cube. Version 4
Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete
Artificial Incubation of Fish Eggs 1
Fact Sheet FA-32 Artificial Incubation of Fish Eggs 1 Craig A. Watson and Frank A. Chapman 2 Many fish species require that their embryos (eggs) incubate and hatch in open water. Eggs are broadcast in
RULE 8-8 - ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS
BAY AREA AIR QUALITY MANAGEMENT DISTRICT RULE 8-8 - ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS (ADOPTED: January 17, 1979) (AMENDED: November 1, 1989; October 6, 1993; June 15, 1994;
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
Iron and manganese are two similar elements
L-5451 2-04 Drinking Water Problems: Iron and Manganese Mark L. McFarland, Associate Professor and Extension Soil Fertility Specialist Monty C. Dozier, Assistant Professor and Extension Water Resources
Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It
Homeowner s Guide for Maintenance and Care of On-Site Sewage Systems It s Your Septic System Here s How to Take Care of It Properly maintaining your septic system will help reduce the possibility of health
Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To:
Sewer Jetter GuideSM How to Unclog Drains with Your Pressure Washer Use this Guide To: Learn how a sewer jetter works Find out if a sewer jetter can help solve your plumbing problem Choose the right pressure
WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )
Page 1 of 76 1.0 PURPOSE The purpose of the Wastewater Treatment System is to remove contaminates from plant wastewater so that it may be sent to the Final Plant Effluent Tank and eventually discharged
RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants
RTV159 RTV157 and RTV159 High Strength Silicone Adhesive Sealants Product Description RTV157 and RTV159 are one-component, ready-to-use, high strength silicone rubber adhesive sealants. They cure to tough
Some Criteria for Choosing a Steam Boiler for a Microbrewery
Some Criteria for Choosing a Steam Boiler for a Microbrewery Jack Coe Rite Engineering and Manufacturing Corporation Breweries rely on steam heating for a number of functions, primarily to heat the brew
Chapter 3: Separating Mixtures (pg. 54 81)
Chapter 3: Separating Mixtures (pg. 54 81) 3.2: Separating Mechanical Mixtures (PB Pg. 40 5 & TB Pg. 58 61): Name: Date: Check Your Understanding & Learning (PB pg. 40 & TB pg. 61): 1. What are four methods
10/20 COMBINATION UNIT
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual 10/20 COMBINATION UNIT with the 255/742 Logix Control Valve With Vortech October 2006 Table of Contents Page No. Topic
Energy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS
OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS THE LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT
Best Basement Water Management Practices
Best Basement Water Management Practices Guide written by Patrick Sluss Sluss Construction (330) 224 5394 When a home owner is faced with a leaking basement there is a way to correct the problem and a
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions
Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can
Plumbing for retail food businesses
Plumbing for retail food businesses Every day, thousands of food outlets in Sydney produce waste, such as cooking oil, grease and food solids. If that waste is discharged directly into our sewers, it can
DRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How to check for leaks Draftproofing products Sealants Draft proofing your home Draftproofing can be a cost-effective measure you take to
Water Treatment & Purification Chemicals
Lime-Out Extra Water Treatment Cleaning Chemicals Dissolves tough lime, calcium & rust stains Non-abrasive thick jelly like liquid clings to vertical surfaces Cleans tubs, sinks, shower doors, dishwashers
IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS800.09. Description. Key Features and Benefits. Typical Physical Properties
1810.html Technical Data Sheet IS800 Series IS802, IS803, IS808, IS800.09 Description IS802, IS803, IS808 and IS800.09 one-component, ready-to-use silicone adhesive sealants have a paste-like consistency
Vacuum chucking. MDAE Woodturning Center Course Number 95537001
Purpose of vacuum chucking Vacuum chucking MDAE Woodturning Center Course Number 95537001 Completing the foot of a vessel Re chucking a completed object Quick securing for additional steps (sanding) How
STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE
Page 1 of 9 PURPOSE Steam is the most commonly used heating medium for maintaining process temperatures. Compared to other heating media, steam contains a significant amount of heat energy, and this heat
KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
Aquaculture Tanks Manufacturer of Fiberglass Aquaculture Tanks Water Cisterns Aquariums Fish Ponds Custom Fabrications
Aquaculture Tanks Manufacturer of Fiberglass Aquaculture Tanks Water Cisterns Aquariums Fish Ponds Custom Fabrications A B C D DOLPHIN FIBERGLASS PRODUCTS has been manufacturing fiberglass aquaculture
SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List
SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List For MG, WG, WGL, and Grinder Pumps for Effluent & Sewage CAUTION! Read these safety warnings first before
Rehabilitation of an Aging Concrete Reservoir Adit Tower
Rehabilitation of an Aging Concrete Reservoir Adit Tower Raymond S. Tombaugh, Senior Coatings Consultant KTA-Tator, Inc. and Mongkol Mahavongtrakul, P.E. Corrosion Control Contract Manager San Francisco
MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model
Steam Coil Installation, Operation and Maintenance
Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils manufactured by Luvata in Grenada, MS have been
APCO SLOW CLOSING AIR/VACUUM VALVES
BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance The Boiler MACT, 40 CFR 63, Subpart DDDDD, was vacated in 2007 by the U.S Court of Appeals and the 2004 rule
Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual
Support Cleaning Apparatus Operation, Cleaning, & Safety Manual Revision 1.1 31 May 2014 WARNING: The instructions and precautionary statements contained herein are intended for the Support Cleaning Apparatus
National Precast Concrete Association
National Precast Concrete Association NOTES 1. This manual does not claim or imply that it addresses any safety-related issues associated with its use. Operation and maintenance of precast concrete grease
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company
Instruction Manual Ultrasonic Cleaning Tank Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company No 1536, Jalan Perusahaan, Kawasan Perusahaan Bukit Tengah, 13600 Perai, Penang, Malaysia.
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors
s Control Analysis Fabrication A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors Eductors Ensure Thorough Mixing to Improve Product Quality and Reduce Maintenance Time Tank mixing eductors
FS Lubricants. Oil Analysis Program
FS Lubricants Oil Analysis Program What can an oil analysis do for you? 1. Establish safe and proper drain intervals. 2. Provide a reduction in unforeseen breakdowns. 3. Reduce down time. 4. Minimize the
Confined spaces. You might go into a confined space to inspect, test, repair, for maintenance or cleaning.
Confined spaces Confined Spaces are areas that are difficult to get into, as well as to get out of. They are not designed to be continually occupied by humans. Poor ventilation and other hazards in these
Waterproofing Problems: A Simple Explanation, A Simple Solution
Waterproofing Problems: A Simple Explanation, A Simple Solution The purpose of this paper is to point out the underlying causes of waterproofing problems and simple means of preventing them. Such problems
BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-
Installation Manual -1- What happens to the water in your pool? This should be a question of prime consideration for all pool owners. In the past some pools did not use filtering systems, the owner was
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
Top 10+ Mistakes of DWV plumbing design
Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of
Installation & Operating Instructions
300 G R A V I T Y F E D Installation & Operating Instructions Note: Do not attempt to operate this unit before reading the manual thoroughly Manufactured by Evolution Aqua Ltd. Evolution House Kellett