3 surface of the insulating unit. This adds depth to the spandrel glass and attenuates the differences in opacity between the vision and non-vision areas. PREL-COAT OPACI-COAT 300 THERMA-SPAN S P A N D R E L G L A S S INTRODUCTION Curtain walls are commonly used as building envelope. It is a lightweight, exterior cladding that usually spans multiple floors and is hung directly on the building structure. The exterior aspect of a curtain wall differs from one system to the next, but they are generally made of metal frames surrounding either glass or metal panels. Heat-Strengthened or Fully Tempered Glass? Spandrel glass is generally heat-strengthened to make it more resistant to the wind loads and high temperatures normally present in non-vision areas of curtain walls. If breakage occurs, the heat-strengthened glass will break into large sections similar to annealed glass. Heat-strengthened glass is twice impact resistant than annealed glass of the same thickness, but it cannot be considered as a safety glass. Tempered glass is usually recommended for more hazardous areas. It is high temperature resistant and is four times impact resistant than annealed glass of the same thickness. If breakage occurs, fully tempered glass breaks securely in small and dull fragments, thus ensuring public safety. Fully tempered glass meets safety glazing standards. STANDARDS ASTM C1036 Flat Glass ASTM C1048 Heat-treated flat glass CAN/CGSB 12.1 Laminated or Tempered Safety Glass CAN/CGSB 12.9 Spandrel Glass Description Spandrel glass panels are opaque and generally used in the non-vision areas of curtain walls. These types of glass panels are placed between the vision areas and are used to mask the materials or construction that could be seen from the exterior of the building. Spandrel glass is available as monolithic glass, laminated glass or insulating glass units. Depending on the colours used, spandrel glass can harmonize or contrast with the glass in the vision areas. MONOLITHIC GLASS Exterior glass Glass surfaces Prelco offers three types of spandrel glass: PREL-COAT: ceramic frit coated glass OPACI-COAT 300 : silicone coated glass THERMASPAN: opacifier film Harmonizing Glass Sections Usually, vision areas of a curtain wall are made of double insulating glass units, while the panels in non-vision areas are made of monolithic glass. To achieve visual uniformity between the vision and non-vision areas, it is best to use glass with a low percentage of visible light transmission (VLT) in both areas. For instance, vision glass units could either be constructed with an exterior tinted glass lite or with a reflective glass with pyrolithic coating on number two surface. For the spandrel glass, the same type of glass could be used with the opaque coating on number two surface. This will create a more uniformed look between the vision and the non-vision areas of the curtain wall. If a medium to high VLT percentage glass is preferred, you can attain a uniformed look by using insulating spandrel units. The opaque coating is then applied on number four LAMINATED GLASS Exterior glass Interlayer Insulating glass Exterior glass Glass surfaces Interior glass Glass surfaces Interior glass Spacer
4 Solar Bronze PC-9904 Evergreen PC 9902 PREL-COAT C E R A M I C F R I T C O A T E D S P A N D R E L G L A S S Solar Gray PC-9901 Lava Bronze PC-9905 DESCRIPTION Ceramic frit coating is applied to the glass using a horizontal roller-coater and then heated in an oven at approximately 1150 F (621 C). Once this treatment is complete, the ceramic frit fuses to the surface of the glass. Ceramic frit is extremely durable and resists to cracks, scratches, discoloration and harsh chemicals. AVAILABLE COLOURS Prelco offers seven standard colours and a large selection of non-standard colours. Non-standard colours are matched to samples provided by the specifier. White PC-9912 GLASS MAKEUP Monolithic Glass Charcoal PC-9903 Ceramic frit coating is applied on number two surface of the support glass*. The support glass must be heat-strengthened or fully tempered. It is not recommended exposing ceramic coating to the elements. Use on number one surface therefore is not recommended. Fallout resistance Black PC-9907 A safety film can be applied to the back of monolithic spandrel glass. If breakage occurs, the film will provide temporary retention of broken spandrels. Laminated Glass Ceramic coating can be applied on number two, three or four surface of a laminated glass*. Each sheet of laminated glass must be heat-strengthened or fully tempered. Large selection of non-standard colours Insulating Glass Opaque coating can be applied on number four surface of an insulating glass. Each glass sheet of the sealed unit must be heat-strengthened or fully tempered. ENVIRONMENTAL PROTECTION Exact colours can vary from the one illustrated above. Always proceed to the evaluation of a sample placed in its final environment. Please contact us to receive exact colour samples. Prelco uses lead free ceramics which are respectful of people and the environment. Light colours may require two applications of ceramic frit coating in order to obtain the desired level of opacity. Please contact us for more details. *Certain conditions apply. Please contact us for more details.
5 Black OPACI-COAT 300 S I L I C O N E C O A T E D S P A N D R E L G L A S S Harmony Blue DESCRIPTION Opaci-Coat 300 is a rubber-like silicone coating applied with horizontal roller-coater or a spray gun in the final stage of the spandrel glass production process (after heat-treating). Once it is applied to the glass, the coating is dried in a low heat oven. Adherence between Opaci Coat 300 and glass is optimal because the materials have very similar cellular structures. This coating is as effective as annealed glass (outdoor use only) or heat-treated glass (heat-strengthened or fully tempered). AVAILABLE COLOURS Prelco offers seven standard colours and a large selection of non-standard colours. Non-standard colours are matched to samples provided by the specifier. GLASS MAKEUP MONOLITHIC GLASS White Harmony Bronze Lava Bronze Silicone coating is applied on number two surface of the support glass*. The glass can be annealed (inside use only) or heat-treated (heat-strengthened or fully tempered). The silicone coating must not be exposed to the elements or to the public. Use on number one surface is therefore not recommended. FALLOUT RESISTANCE Harmony Grey Opaci-Coat 300 coating, upon application, is approximately in. (0.20 mm) thick to provide proper glass opacity. Applied in thicker coat, Opaci-Coat 300 acts as a safety film that provides temporary retention of broken spandrel. In this case, the coating must be applied at a wet film thickness of in. (0.33 mm). Laminated Glass Silicone coating can be applied on number four surface of a laminated glass*. For exterior use, each sheet of laminated glass must be heat-strengthened or fully tempered. Harmony Solex Insulating Glass An opaque coating can be applied on number four surface a sealed unit. Each lite of the insulating glass must be heat-strengthened or fully tempered. Large selection of non-standard colours ENVIRONMENTAL PROTECTION Opaci-Coat 300 coating is free of lead, organic solvents and is self-extinguishing. The glass can be manipulated without fear of personal or environmental harm. Exact colours can vary from the one illustrated above. Always proceed to the evaluation of a sample placed in its final environment. Please contact us to receive exact colour samples. *Certain conditions apply. Please contact us for more details. Opaci-Coat 300 is a trade mark of Industrial Control Development Inc. Light colours may require two applications of coating to obtain the desired level of opacity. Please contact us for more details.
6 SMF-1/W SMF-1/BK SMF-2/W SMF-2/BK THERMA-SPAN F I L M C O A T E D S P A N D R E L G L A S S SMF-3/W SMF-4/W SMF-5/W SMF-6/W SMF-3/BK SMF-4/BK SMF-5/BK SMF-6/BK DESCRIPTION Therma-Span is an opaque polyester film. It can be either or in. (0.076 or 0.10 mm) thick, and is applied to the surface of the glass with horizontal rollers at the final stage of the production process (after heat-treating). The film is coated with a pressure-sensitive adhesive and applied to the glass using a process called dry laminating. Dry laminating is performed in a clean room equipped with dust filters. Therma-Span is a cost-effective film that resists to discoloration, humidity, oxidation and high temperatures. AVAILABLE COLOURS Therma-Span is available in two metallic finishes: White (W) or Black (BK). The number of available colours is multiplied by applying the film to various types of glass (i.e. clear, tinted or reflective glass). GLASS MAKEUP Monolithic Glass Therma-Span film can be applied on number two surface of a support glass*. The glass can be annealed (interior use only) or heat-treated (heat-strengthened or fully tempered). We do not recommend exposing the film to the elements or to the public. Use on number one surface is therefore not recommended. Fallout resistance Therma-Span acts as a safety film and provides temporary retention of broken spandrel. SMF-7/W SMF-7/BK Laminated Glass Therma-Span film can be applied on number four surface of a laminated glass*. For exterior use, each sheet of glass must be heat-strengthened or fully tempered. SMF-8/W SMF-8/BK Insulating Glass This opaque film can be applied on number four surface of a sealed unit*. Each lite of the insulating glass must be heat-strengthened or fully tempered. Exact colours can vary from the one illustrated above. Always estimate a sample by doing an in-field examination. Please contact us to receive exact colour samples. *Certain conditions apply. Please contact us for more details.
7 Compatible Sealant and Trims Installing spandrel glass requires products which are compatible with the type of opaque coating used. For instance, spandrel glass coated with Opaci-Coat 300 must be installed with silicone setting blocks. Please contact us or visit our Web site at for more information or to obtain a list of compatible products. INSTALLATION Insulated Metal Pan To increase the level of thermal insulation in the non-vision areas of curtain walls, insulated metal pan are usually added behind spandrel glass. These metal pans are generally supplied by the curtain wall installer. Uniform Backgrounds Spandrel glass is designed to be installed against dark uniform backgrounds. Therefore, light colours may require using a lighter background. It is recommended to always evaluate a sample properly by placing it in its final environment. Spandrel glass is designed to be installed against opaque backgrounds and one should not be able to see through it. Please contact us before setting up any application allowing the light shine through the glass. Structural Silicone Glazing Certain curtain wall systems allow the installation of the glass panels without exterior pressure plates. Thus glass panels are installed to the metal structure with structural silicone sealant. When spandrel glass panels are installed this way, it is absolutely necessary to delete an opaque coating strip along the edge of the glazing. This edge deletion will provide optimal adhesion between the glass and the structural sealant. The width of the strip varies depending on the type of curtain wall, but 3/8 in. (10 mm) is generally the norm. It is not necessary to edge delete spandrel glass coated with ceramic frit. Spandrel Glass Ventilation Always provide a sufficient air gap at least 1 in. (25 mm) behind the spandrel glass in order to let humidity and excess heat circulate properly. *Certain conditions apply. Please contact us for more details.
8 94 boulevard Cartier Rivière-du-Loup (Québec) Canada G5R 2M9 T F sales@prelco.ca Printed in Canada SP20708 CAN: US: Graphic design: The information contained herein is, to the best of our knowledge and belief, correct. This information is intended for reference purposes only. In no event wil Prelco MD be responsible for faulty usage of this product. The information contained herein may change as new developments occur and further experience is gained.
Spandrel Glass Types and Recommendations
Spandrel Glass Types and Recommendations Introduction PPG has long offered recommendations regarding alternatives for glass spandrel applications. Over the years these recommendations were included in
More informationAssessing Curtain Walls
Assessing Curtain Walls Considerations and Best Practices Paul E Beers GCI Consultants, LLC pbeers@gciconsultants.com What is a Curtain Wall System? A curtain wall system is an outer covering of a building
More informationDow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
More informationHeat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS
Heat-treated Heat-treated Glass Glass Heat-treated Glass Heat-treated Heat-treated Glass Glass REFLECTIVE GLASS LAMINATED GLASS TEMPERED GLASS FLOAT GLASS MIRRORS LOW-E GLASS SUNGUARD PATTERNED GLASS HORTICULTURAL
More informationHandling, Inspecting, Fabricating & Glazing Pilkington Solar-E on Tinted Glass
Technical Bulletin ATS-190 Handling, Inspecting, Fabricating & Glazing Pilkington Solar-E on Tinted Glass Summary The Pilkington Solar-E low emissivity pyrolytic coating on tinted glass improves thermal
More informationThermal Breakage Prediction
Thermal Breakage Prediction The prediction of glass breakage due to thermal stress is an important analysis for the longevity of a window. Thermal breakage occurs when there is a large temperature differential
More informationINFORMATION REGARDING GLASS TYPES AND PROPERTIES
INFORMATION REGARDING GLASS TYPES AND PROPERTIES 1. Float Glass Float Glass is annealed glass processed by combining all ingredients and heating them till molten. This molten glass is then poured over
More informationSCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
More informationGlass Technical Document
INTRODUCTION PPG has for many years recommended that early design considerations regarding the use of glass on commercial projects include evaluation of potential thermal stress breakage. Thermally induced
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationMIROX 3G ENVIRONMENTALLY- FRIENDLY MIRROR
MIROX 3G ENVIRONMENTALLY- FRIENDLY MIRROR One step closer to perfection MIROX 3G is a unique product and AGC Flat Glass Europe holds the exclusive patent for the manufacturing process. It is the third
More informationPintura is a color coated glass product manufactured. by Pulp Studio, Inc, and is ideally suited for commercial
PRODUCT REPORT Pintura is a color coated glass product manufactured by Pulp Studio, Inc, and is ideally suited for commercial and residential spaces. Headquartered in Los Angeles California, Pulp Studio
More informationSun Vinyl New Construction Windows Homeowner's Warranty
Sun Windows Sun Vinyl New Construction Windows Homeowner's Warranty Vinyl Sun Windows, Inc. warrants for a period of 2 years that the quality of workmanship and materials of vinyl items shall be free from
More informationfoot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
More informationA. Work on this project shall consist of, but is not limited to, the following:
PART 1 - GENERAL CLEANING AND RESTORATION OF SECTION 05900-1 1.1 SUMMARY A. Work on this project shall consist of, but is not limited to, the following: 1. Clean and treat all exposed anodized architectural
More informationDouble Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.
Double Glazing Glass Energy Saving Solutions Harris Silicones & Glass (Pvt.) Company Introduction Pioneers of Silicone Sealants in Pakistan Manufacturing in collaboration with Momentive Performance Materials
More informationGlass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
More informationImpact-Resistant Windows and Sliding Glass Doors
Impact-Resistant Windows and Sliding Glass Doors Make Your Home A SafeHarbor. SafeHarbor Impact-Resistant Windows and Sliding Glass Doors are designed to look like traditional windows and doors, but they
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationWindows are one of the most important components of a
design concepts Arjun Kamal MAKING BETTER INDOOR ENVIRONMENTS WITH ENERGY-EFFICIENT WINDOW DESIGN An insight into the various technologies used for constructing windows, and an attempt at understanding
More informationDespite spending many thousands of pounds on a beautiful new conservatory, it is a sad fact that many suffer from intolerable heat and glare problems
Despite spending many thousands of pounds on a beautiful new conservatory, it is a sad fact that many suffer from intolerable heat and glare problems during the summer making them virtually unusable for
More informationPilkington Reflite Handling and Processing Guidelines Solar Control
Pilkington Reflite Handling and Processing Guidelines Solar Control Pilkington Reflite 1. Product description Pilkington Reflite is a hard, on-line coated, solar control glass, available in a range of
More informationTractor Painting Tips
Keeping your tractor or equipment well kept & free from rust & corrosion will extend the life of your investment & help retain its value for a longer period of time. It can be difficult, in many cases,
More informationSECTION 08 87 13 WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationTECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass
Data Sheet Pilkington Toughened Safety Glass Introduction Pilkington has manufactured and marketed toughened glass for over 60 years. Its properties and performance have been proven in countless applications,
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationFIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
More informationScottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO
Scottsdale, Arizona Presentation by: Hermes Norero, P.E. President and CEO Mr. Hermes F. Norero, P.E. is the founder and President of Building Drops. The concept of Building Drops first arose after realizing,
More informationPyroguard Wired Glass
Fire-rated Glass Pyroguard Wired Glass Where glass becomes architecture Section 15 03 Introduction Oldcastle Glass stocks nonwired Pyroguard laminated safety glass and polished wired glass for commercial,
More informationSECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
More informationLight Architecture. Colors Sweden. Light
Light Architecture Danpalon is the complete daylighting solution offering exceptional quality of light, thermal insulation and UV protection with a rich non-industrial visual appeal. The Danpalon system
More informationOLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com
OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide GeneralShale.com OLD BRICK ORIGINALS THIN BRICK VENEER Page 2 INTRODUCTION Check local building codes for proper installation guidelines
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationWindow Glass Design 5 According to ASTM E 1300
A User s Guide to: Window Glass Design 5 According to ASTM E 1300 A product of: 1 Table of Contents Table of Contents List of Figures Chapter 1: Window Glass Design 5 1.1 Introduction 1.2 Features ii iv
More informationPERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall
Architectural Testing PERFORMANCE TEST REPORT Rendered to: UNITED STATES ALUMINUM CORPORATION SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall Title Summary of Results Air Infiltration
More informationUnbeatable energy efficient glass curtain wall system
Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics
More informationMetal Wall Panels. Colorweld 300 Architectural Finishes
Metal Wall Panels Colorweld 300 Architectural Finishes Metal Wall standard architectural finishes These products are protected and colored with high-performance Colorweld 300 coatings ensuring precise
More informationTested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)
THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types
More informationIntroduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.
In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance
More informationSaint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)
Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Gyproc Plasters The cracks in cement sand plaster are an inherent feature which cannot be completely prevented but can only be controlled and
More informationAST M F 1642-04/GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M
AST M F 1642-04/GSA TS01 T EST R EPO R T Rendered to: UNI T E D ST A T ES A L U M INU M SE RI ES/M O D E L : B W3250 PR O DU C T T YPE : Aluminum Combination Fixed Window Summary of Results Title Test
More informationWindows, French doors, folding windows, terrace doors SFB 1074 with low U-values
Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values SFB 1074 is available in two versions. In the first version the profiles are insulated with 30 mm glass fibre reinforced
More informationSunGuard IS 20 Technical Information
BUILD WITH LIGHT SunGuard IS 20 Technical Information SunGuard IS 20 interior-surface coating delivers superior thermal performance with striking clarity. Offering strength, durability, and cleanability
More information7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME
7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved
More informationStiles. Basic Glass Guide. Steel Door + Window Systems CONTENTS
Stiles Basic Glass Guide 1885 Kinser Road Ceres CA USA 95307 T 209 / 538-3667 F 209 / 538-2776 www.stilesdoor.com This guide has been prepared as a basic introduction to standard types of glass. It is
More informationSelecting Energy-Efficient Windows
Selecting Energy-Efficient Windows E N E R I N F O A D V I S O R S E R I E S Key Points Improving the energy performance of windows is important, since windows are the least insulated surface of most homes.
More informationA Complete Solution CREATING WALLS THAT DEFINE SPACE
A Complete Solution CREATING WALLS THAT DEFINE SPACE COMPANY HISTORY CLIPPER WALL Clipper partitions are part of the Saint- Gobain Group, one of the worldwide leaders in the construction products industry.
More informationArchitectural Testing
FIELD AND MOCK-UP TESTING SERVICES 130 Derry Court York, PA 17406-8405 phone: 717-764-7700 fax: 717-764-4129 www.archtest.com Mock-up Test Methods (Laboratory Mock-up or Field Mock-up): ASTM E 283, Standard
More informationK2 STONE NATURAL VENEER
INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin
More informationSika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
More informationTIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings.
Product Data Sheet SERIES 69 - DRYZINC ZINC-RICH PRIMER (69/90500) Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield system. Designed to impart superior corrosion protection to steel
More informationFire-Rated Glass and Glazing START
Fire-Rated Glass and Glazing START www.pilkington.com/fire Fire-Rated Glass and Glazing Pilkington Fire Protection Glass North America 946 Kane Street, Suite A Toledo, OH 43612 Provider Number: J200 Course
More informationT H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L AT I O N I N S T R U C T I O N S C A R E F U L LY CAR
More informationQuality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems
Method of Test Committee Approval Product Group Approval Approved via 5/21/15 MOT CC Out for Ballot (#805-15) PUBLICATION NO. AAMA 501.2-XX DRAFT #2 DATED 5/21/15 Quality Assurance and Diagnostic Water
More informationPeel Adhesion of Pressure Sensitive Tape
Harmonized International Standard Call Letters PSTC 101 Date of Issuance 10/00 Revised 10/03 Revised 05/07 Peel Adhesion of Pressure Sensitive Tape 1. SCOPE 1.1 These methods cover the measurement of the
More informationNEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
More informationLaminating Films - Heat Activated
Laminating Films - Heat Activated Print Guard UV This film features superb ultraviolet protection at low activation temperature (185º F - 195º F) and an aggressive solvent acrylic adhesive. Linerless Print
More informationConcepts. Products. Service. 30 Crown Place, London EC2
Concepts Products Service 30 Crown Place, London EC2 1 Project Report 30 Crown Place, London EC2. Bold design makes this a striking addition to the London skyline. Occupying an important site close to
More informationTECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic
- TECHNISCHE FICHE - Chat Board: Classic Classic is a magnetic glass- and writing board for use in modern offices and private homes. CHATBOARD Classic is Danish Design - made in Denmark. Classic is a glass
More informationApplication Note. Soldering Methods and Procedures for 1st and 2nd Generation Power Modules. Overview. Analysis of a Good Solder Joint
Soldering Methods and Procedures for 1st and 2nd Generation Power Modules Overview This document is intended to provide guidance in utilizing soldering practices to make high quality connections of Vicor
More informationPERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
Architectural Testing PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Mahogany Entry Door PRODUCT TYPE: 6' x 8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom
More informationHeavy Glass Frameless Shower Door With Return Panel
202 Anderson Ave., elvue, KS 66407 Phone: 800-669-9867 Fax: 800-393-6699 www.onyxcollection.com Heavy Glass Frameless Shower Door With Return Panel Full Showers with Return ench Seat with Return FRLSDRPL-0116
More informationTypes Name Description. Films Polyethylene 4 and 6 mil Regular UV. Rigid Plastics Fiberglass" Fiber reinforced. "Plexiglass" or equal
Greenhouse Coverings One of the most important parts of a greenhouse facility is the covering. Since sunlight is generally the limiting factor in wintertime greenhouse production, a covering that transmits
More informationHeating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
More informationAvoiding Air Barrier Pitfalls
Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great
More informationSALES (800) 445-6607 FAX
Acrylic Information Cell Cast Acrylic Sheet comes in a wide range of sizes and thicknesses and is available as a colorless sheet, as well as in a variety of transparent, translucent and opaque colors.
More informationCHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS
CHANNEL LETTERING INDOOR & OUTDOOR SIGNAGE TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS info@muizgraphics.com www.muizgraphics.com Tel: 905-362-0268
More informationBeautifully Traditional
Arcade 800mm Single Sliding Door Quadrant - nickel Arcade 900mm Single Sliding Door Quadrant - nickel ARC48 ARC49 INSTALLATION INSTRUCTIONS A www.arcadebathrooms.com IMPORTANT - Please read before installation
More informationAutomotive Engineered Attachment Systems
Automotive Engineered Attachment Systems (TR-12721) Technical Data Sheet Acrylic Foam RT8000 Series General Information : The acrylic Foam RT8000 Series, which is made by a special process, has a superior
More informationRoller Wave Distortion Definition, Causes and a Novel Approach to Accurate, On-line Measurement
Roller Wave Distortion Definition, Causes and a Novel Approach to Accurate, On-line Measurement Mark Abbott & John Madocks Applied Process Technologies, Inc. Keywords 1 = Roll distortion 2 = Visual Inspection
More information- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
More informationMolds and mildew are fungi that grow
Appendix C: Moisture, Mold and Mildew Molds and mildew are fungi that grow on the surfaces of objects, within pores, and in deteriorated materials. They can cause discoloration and odor problems, deteriorate
More informationAAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY
Architectural Testing AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT Rendered to: EAGLE WINDOW & DOOR COMPANY SERIES/MODEL: Series 01 Axiom Clad One-Piece Casement Fixed 6060 PRODUCT TYPE: Aluminum Clad Fixed
More informationMOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up
MOCK-UP TEST REPORT Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up Report No: 85616.01-120-32 Test Completion Date: 01/15/09 Report Date: 02/11/09 Record Retention End Date: 01/15/13
More informationDL CHEMICALS DECO SNJF PARAFILL PARQUET EXTERIOR TRANSPARENT STRUCTURE
EN DL CHEMICALS DECO SNJF PARAFILL PARQUET EXTERIOR TRANSPARENT STRUCTURE QUICKLY REPAINTABLE NON-CRACKING MATT REMAINS MATT EASY TO APPLY A quickly repaintable elastic sealant based on acrylic dispersion.
More informationThe Anatomy of a Label
The Anatomy of a Label Three key elements make up a label: face stock, release liner, and adhesive. Face Stock: Face stock is the material of the label that carries the imprint. The print can be applied
More informationWilliamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, 2013. (68 pages)
INNOVATIVE BUILDING AND ARCHITECTURE CONSULTANTS Mr. Bud Hall Senior Vice President of construction Turnberry Associates 19501 Biscayne Boulevard, Suite 400 Aventura, FL 33180 Subject: The Nashville Hilton
More informationTreatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.
Recommend Approval: Team Leader Date Division Chief Date Approved: Director Date Maryland Department of Transportation State Highway Administration Office of Materials Technology MARYLAND STANDARD METHOD
More informationGigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
More informationBuilding Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationMaintenance Matters. Window and Door Replacement
Number 13 Maintenance Matters building maintenance bulletin Window and Door Replacement As part of the ongoing maintenance of your home or multi-unit residential building, windows and doors will eventually
More informationIn the Fall 2002 issue of HHE News I examined
Choosing Replacement Windows 1 For Your Home Mark Pierce In the Fall 2002 issue of HHE News I examined reasons for, and against, replacing older windows with new, energy efficient windows. That article
More informationModel WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description
Worldwide Contacts www.tyco-fire.com Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description The TYCO Model WS Specific Application Window
More informationINNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
More informationASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider
ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider Report No.: Test Date: 5/21/07 Through: 5/23/07 Report Date: 5/30/07
More informationARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials
ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials SECTION 03 92 50 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings,
More informationASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT Rendered to: BEKAERT SPECIALTY FILMS, LLC SERIES/MODEL: Panorama 8-mil Film PRODUCT TYPE: Fixed Window with Applied Film This
More informationARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
More informationInstallation Instructions for Fletco Carpets
Table of Contents The backing is a very important part of a carpet, as well as the installation and the daily use are concerned, so therefore these installations instructions are based on the different
More informationCOMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
More informationI-Line - Snap-On Feature
Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects
More informationSPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING. 16.1 General...16-1. 16.2 Materials...16-1. 16.3 Equipment...
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING TABLE OF CONTENTS 16.1 General...16-1 16.2 Materials...16-1 16.3 Equipment...16-1 16.4 Installation...16-2 16.4.1 Traffic Restrictions...16-2
More informationThe Warm Edge for insulating glass
The Warm Edge for insulating glass 1. 3. SGGSWISSPACER 2. 4. The best product on the market by quite an edge Energy saving Lower heating costs through better insulation: the thermally improved spacer SGG
More informationClassification of reaction to fire of glass products Recommendation from Glass for Europe
Classification of reaction to fire of glass products Recommendation from Glass for Europe April 2015 Glass for use in buildings and construction works shall declare a reaction to fire performance in their
More informationFLEXIBLE CIRCUITS MANUFACTURING
IPC-DVD-37 FLEXIBLE CIRCUITS MANUFACTURING Below is a copy of the narration for DVD-37. The contents of this script were developed by a review group of industry experts and were based on the best available
More informationKIP MEDIA GUIDE. US Media Guide
KIP MEDIA GUIDE US Media Guide KIP MEDIA GUIDE Product Categories Application Categories Model Architectural and Engineering (A/E/C) Geographic Information System (GIS) Posters and Presentations Trade
More informationPeninsula Place, Greenwich, London
Concepts Products Service Peninsula Place, Greenwich, London 1 Project Report Peninsula Place, Greenwich, London Designed as one of the most sustainable commercial buildings in the UK, with a BREEAM rating
More informationTechnical Information. What you need to know to BUILD WITH LIGHT
Technical Information What you need to know to BUILD WITH LIGHT Introduction 1 Types of Glass 2 Annealed Glass Heat-strengthened Glass Tempered Glass Laminated Glass Insulating Glass Warm-Edge Spacer Tinted