Air-Alarm1 D.I.Y. Wireless Home Alarm System Kit
|
|
|
- Clifton Small
- 10 years ago
- Views:
Transcription
1 Air-Alarm1 D.I.Y. Wireless Home Alarm System Kit USER s MANUAL
2 Copyright Notice This manual is furnished under license and may be used or copied only in accordance with the terms of such license. Except as permitted by such license, no part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or any means, electronic, mechanical. Recording, or otherwise, including translation to another language or format, without the prior written permission of SecurityMan. The content of this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by SecurityMan. SecurityMan assumes no responsibility or liability for any errors or inaccuracies that may appear in this document. All other product names, trademarks and registered trademarks in this document are the properties of their respective holders. FCC Information Notes on FCC s Consistent Statement of Information This product meets the requirements specified in Part 15 of FCC Regulation. Operation rests with the following two conditions: (1 ) The equipment should not cause any harmful interference. (2 ) The equipment must receive and process any interference, including any possible interference caused by operation mistakes. Warranty SecurityMan warrants this product will be free from defects in materials and workmanship for the period of time specified on the product packaging. This limited warranty shall commence from the date of purchase. SecurityMan Products warranty is not transferable and is limited to the original purchaser. If the product is found to be defective then, as your sole remedy and as the manufacturer s only obligation, SecurityMan will repair or replace the product. This warranty shall not apply to products that have been subjected to abuse, misuse, abnormal electrical or environmental conditions, normal wear and tear or any condition other than what can be considered normal use. Limitation of Liability The liability of SecurityMan arising from this warranty and sale shall be limited to a refund of the purchase price. In no event shall SecurityMan be liable for costs of procurement of substitute products or services, or for any lost profits, or for any consequential, incidental, direct or indirect damages, however caused and on any theory of liability, arising from this warranty and sale. These limitations shall apply not withstanding any failure of essential purpose of any limited remedy. SecurityMan 4601 E. Airport Drive, Ontario, CA 91761, USA Tel: or Fax: [email protected] Website: Copyright 2008 by SecurityMan v4.0
3 Table of Contents Introduction Package Contents Main Features Alarm Host (SM-8088E) Alarm Host Specifications (SM-8088E) Three types of Defense Line Programming the Alarm Host (SM-8088E) To Setup User Code (For Ademco Managemant Center) How to change the programming password Operation Understand and Setup Wireless Accessories Wireless Remote Controllers (SM-88X) Wireless Door/Window Sensor (SM-87B) Wireless Wide-Angle PIR Motion Sensor (SM-80) Wireless Indoor Siren (SM-103W) Wireless Smoke Alarm (SM-93, optional) Wireless Outdoor Siren (SM-103, optional) Wireless Panic Button (SM-89, optional) Air-Alarm Defense Zone Code Chart Manufacturer Wireless Default Setting Common Problems and Solutions Daily Maintenance and Care Accessories Air Alarm Frequently Asked Questions
4 Introduction SecurityMan Air-Alarm1 is a state-of-the-art wireless alarm system kit for homes and businesses. It is user-friendly and easy to use protecting homes/ businesses at a minimum cost of investment. Do-It-Yourself installation and monitoring alarm system without monthly fees is a key benefit for users. The system will alert by phone calls to owner through a series of enlisted phone numbers. The owner can then dial into the host to arm or disarm the alarm by using the phone s numeric keypad. The Air-Alarm1 system can be upgraded by adding up to 60 wireless sensors, sirens, and up to 8 remote controllers. Package Contents 1 x Air-Alarm1 host with built-in LEDs, keypad, and speaker. 1 x Host Anchor Card for Fixed Position. 1 x 12VDC Power Adapter 1 x Wireless Wide-Angle PIR Motion Sensor with Mounting Bracket (Battery Included) 1 x Wireless Magnetic Door/Window Sensor with Mounting Bracket (Battery Included) 1 x Wireless Indoor Siren 2 x Wireless Remote Controller (Battery Included) 1 x Phone Cable(3ft) 1 x Warning Sign 1 x User s Manual Accessories (on page 22) Main Features Easy-to-use and cost-effective D.I.Y. (do-it-yourself) wireless intruder alarm system kit. Supports up to 60 wireless sensors (15 wireless defense zones and 4 wireless sensors per zone). Transmit at MHz frequency band, wireless transmitting distance up to 300 feet (remote controller, smoke sensor, and siren) and up to 450 feet (magnetic door/window sensor & PIR motion sensor) Supports up to 5 phone numbers for auto alarm call and 1 management center protocol (CID). Armed/disarmed by remote controller, phone call, or host s keypad. Easy one-key armed/disarmed operation. 1
5 Programmable silent alarm or audible alarm. Recordable alarm voice message (up to 9 seconds record time). Telephone line disconnection alarm sound every 5 seconds. Smart 3 defense lines configuration-1st defense line is the perimeter, 2nd defense line for in-room, & 24-hour defense line. Internal rechargeable backup battery in alarm host lasts up to 8 hours. Battery included for remote controllers, wireless door sensor, and wireless motion sensor last up to 2 years. Programmable password. Ademco CID compatible protocol Alarm Host (SM-8088E) * In off mode, the alarm host will still operate normal if the AC power is connected. * For wall mount please use screw (B) (see page22) 2
6 Alarm Host Specifications (SM-8088E) Operating power: 9-15VDC Static current: 60mA Alarm current: 380mA Operating environment: Temperature: -10 ~ 50 C Humidity: <80% Maximum available quantity of remote controllers: 8 PCS Maximum available quantity of wireless sensors: 60 PCS Dimensions: 180X120X38 (mm) Rechargeable battery: Ni-Mh(4.8v), 600mAh, up to 8hrs long Speaker siren 100dB (built-in) Three types of Defense Line Types of Defense Line and what they mean: 24-hour Defense Line (Zone 1~5): Indicates the detecting defense areas in a 24-hour monitoring device, commonly used in areas such as emergency distress, medical rescue, gas leakage, fire alarm, and etc. These zones are generally composed of panic buttons, wireless gas sensors(n/a), and wireless smoke sensors. 1st Defense Line (Zone 6~10): Indicates the first detecting defense areas or the perimeter zone (such as doors and windows). This is the perimeter areas where thieves initiate when attempting to break in. These zones are generally composed of wireless door magnet sensors and wireless curtain PIR sensors. (N/A) 2nd Defense Line (Zone 11~15): Indicates the second detecting defense areas, such as living room, aisles, bedrooms, hallways, etc. These zones are generally composed of the wireless wide-angle PIR sensors where they can detect movements in open spaces. 3
7 Programming the Alarm Host (SM-8088E) _Function_:_Operation Operation Explanation Notes: 1. The alarm host will automatically exit from the programming status if inactive for 20 seconds. 2. Programming is effective after _SET+Password+ENT_, use ESC button to go to previous step. 3. The alarm host will beep in series to indicate the operation is successful and beep once to indicate operation failure. _:_SET + Password + ENT This command applies throughout whenever programming the alarm host, before attempting to change other programming features, such as Delay Time to Arm, Delay Time to Alarm, Emergency Alarm Voice, Adding and Cancelling wireless devices, etc. For example; to change Delay Time to Arm below from the default 40 seconds to 1 minute, press_set ENT_ follow by _15 + ENT_. The programming default password is 888 (3 digits long), and 15 is the programming code for 1 minute. _Input Alarm Telephone Number_ : _XX + ENT + Telephone Number + ENT XX indicate telephone group number which can be of personal numbers or management center. See group details below: 01: Group 1 (personal telephone number) 02: Group 2 (personal telephone number) 03: Group 3 (personal telephone number) 04: Group 4 (personal telephone number) 05: Group 5 (personal telephone number) 06: Group 6 (reserved for CID Protocol number for management center, not for personal numbers, requires monthly fees) To delete or reset the telephone enlisted number press, SET+password+ENT+XX+ENT+ENT (XX is the group number, ie. 01, 02, etc.) _Delay Time to Arm_: _XX + ENT Setup a dwell time in which the alarm will become activated or armed. Enter 10 for XX to setup Delay Time to Arm for 40 seconds, enter 15 to setup Delay Time to Arm for 1 minute and press the ENT button to confirm. The default setting is 10 or 40 seconds alarm dwell time. If armed, any wireless triggers within the dewll time of 40 seconds or 1 minute, the Alarm Host will beep twice. _Delay Time to Alarm_: _XX + ENT Setup a dwell time in which the alarm will sound or trigger. Enter 20 for XX to setup immediate alarm sound triggering, enter 21 to setup a 15 seconds Delay Time to Alarm. The default setting for Delay Time to Alarm is 20. _Emergency Alarm Sound_: _XX + ENT Enter 30 for XX to disable Emergency Alarm Sound, enter 31 to setup audible alarm sound, the default is 31. During the Emergency Alarm Sound is disabled or set to 30; the alarm host will operate normal, and will continue to dial the enlisted phone numbers in case of emergency. 4
8 _Alarm Sound for 1st and 2nd defense line_: _XX + ENT Enter 40 for XX to disable alarm sound for 1st & 2nd defense line, enter 41 to enable Audible alarm, the default is 41. When the Alarm Sound is disabled or set to 40; the alarm host will operate normal and will continues to dial the enlisted phone numbers upon alarm trigger. _Telephone Disconnection Alarm_: _XX + ENT Enter 60 for XX to disable Telephone Disconnect Alarm, enter 61 to enable Telephone Disconnect Alarm, the default is 61. Telephone Disconnection Alarm is line of integrity alarm. That chirps every 5 seconds when the telephone line is not connected to the TEL IN port of the alarm host panel. To disable the chirping when the telephone is not plugged in to the host; press, SET+password+ENT+60+ENT. _To upload arm/disarm to management center_: _XX + ENT Enter 50 to disabled upload, enter 51 to enable upload to management center, the default setting is 50 or disable. Leave this disable if management center is not in service. _User Code_: _80 + ENT + XXXX + ENT Enter a number between 0000~9999 for XXXX to setup user code for management center. The default is set as random; apply to management center use only. To Setup User Code (For Ademco Management Center): _SET ENT + press button + ENT + enter programming code + ENT + 3 digits user s code + ENT + re-enter user s code + ENT press SET and programming will appear, enter 999 press ENT and then press page up/down to choose revise user s code and press ENT, enter programming code, press ENT enter 6 digits user s code, and press ENT, reenter user s code, and press ENT. Note: user s code cannot be same as programming password 999 and programming code! Press ESC to exit from programming when finished. How to change the programming password _SET ENT + Three Digit New Programming Password + ENT + Three Digit New Programming Password + ENT Press SET button, the programming LED light will come on, enter 999, press ENT, then input a new three-digit programming password, press ENT, re-input the new three-digit programming password, and then press ENT to complete the programming password change. Notice the programming LED light will disappear after the final ENT is pressed. 5
9 Operation To Record a voice message greeting: Slide the switch on the left side of the alarm host to the RECORD ON position, press and hold the microphone button, speak close (6 ) into the rear speaker of the host, and then release the microphone button when finished with your voice message greeting. Voice message greetings can be anywhere between 0~9 seconds long. To Playback the recorded voice message greeting: Slide the switch on the left side of the alarm host to DC ON, press and hold the playback to playback the recorded voice message greeting. An alarm sound message is pre-recorded by default. button One-key Arm: By Remote controller: Press the AWAY (All Alarm) or the HOME (Part Alarm) button on the remote control to arm and the alarm host will beep once to confirm the operation is successful. See Wireless Remote Controller on page 8 for more detail. By Keyboard on alarm host: Press (All Alarm) or (Part Alarm) button, the alarm host will beep once to confirm the operation is successful. One-key Disarm: By Remote controller: Press the DISARM button on the remote control to disarm the alarm and the alarm host will beep twice to confirm the operation is successful. Disarm by keyboard on alarm host: _ESC/Disarm + Programming Password + ENT Press the ESC/Disarm button follow by the programming password and then ENT to disable alarm siren using the alarm host. The host will beep twice to confirm the operation is successful. Emergency/Panic Distress: By Remote controller: Press the EMERGENCY alarm host and wireless sirens. button on the remote control at times of emergency to immediately activate the sound siren on the By Keyboard on alarm host: Press the EMERGENCY alarm host and wireless sirens. button on the alarm host at times of emergency to immediately activate the siren sound on the Telephone alarm: After receiving the phone call from the alarm host, the recorded voice message will repeatedly play for 22 seconds. Before the 22 seconds are over, one of the following actions must be taken: A) Press the number 8 on the phone pad to extend the time intervals for an additional 20 seconds to enter the listening state. In the listening state the built-in microphone on the alarm host will be active to pick up any sound that takes place near by the alarm host. B) Press the pound # button to replay the recorded voice message. 6
10 C) Press the star * button, the host will end/drop the call and stop to dial the next enlisted alarm telephone numbers. After the * is pressed; the alarm host will resume to be armed Note: the is required in order to stop the alarm host from continuing to dial the next enlisted telephone numbers. D) Hang up the telephone without any command input, the host will end the call and automatically continues to dial the next enlisted alarm telephone numbers. Long distance arm by phone: 30 seconds after successfully dialing the telephone number of alarm host, there will be: a beep > enter programming password of host > beep > enter 1 > beep, and the host will then automatically hang up after the last beep to successfully complete the operation. Note: Long distance arm by phone requires the alarm host to be armed or in the Away mode. Long distances disarm by phone: 30 seconds after successfully dialing the telephone number of alarm host, there will be: a beep > enter programming password of host > beep > enter 0 > beep, and the host will then automatically hang up after last beep to successfully complete the operation. Alarm dialing mode: After the alarm host triggers or goes off, the alarm host will start to dial the first enlisted telephone number, then the second, third, fourth and so on. Unless one of the enlisted telephone numbers answers otherwise this routine auto dial will continue through a series of loop for three times. Alarm priority: If the telephone line is busy when the alarm host goes off, the alarm host will automatically cut off the busy/used line and resume automatic dialing to the enlisted alarm telephone numbers to advise of the crime. Telephone line disconnection Alarm: If the telephone line is cut or comes off the hook, the host will beep every 5 seconds after the telephone line has been cut off or disconnected. It will continue to beep until the phone line is fixed or reconnected. AWAY Mode (Zone 1~15): In this state, after any detection in the 1st, 2nd, or 24hr defense line is triggered, the alarm host will immediately sound the sirens and at the same time automatically dial the enlisted alarm telephone numbers in sequence. HOME Mode (Zone 6~10): In this state, after any detection in the 1st or 24hr defense line is triggered, the alarm host will immediately sound the sirens and at the same time automatically dial the enlisted alarm telephone numbers in sequence. In HOME mode, the 2nd defense line will be disabled and will not trigger the alarm host. 7
11 Understand and Setup Wireless Accessories Please note that all the devices included with the Air-Alarm1 kit is paired to the Alarm Host (panel) by default. If sensing devices does not trigger the Alarm Host, please reference to the To Add: instructions in the user s manual to add the wireless devices accordingly. All newly add-on sensing devices is required to be pair with the Alarm Host. Wireless Remote Controllers (SM-88X) Functions/Features: Used to arm & disarm alarm host. Emergency button for emergency or panic help. Specifications: Operating power: 27A 12V Battery (Recommend: alkaline battery) Wireless Transmitting distance: 300ft (in open area) Service life: 2 years Installation and Usage: Ideal for keychain and to take with you when the alarm host is in the AWAY mode. Press the AWAY button to arm before leaving home and press the DISARM button to disarm. 8
12 Press the HOME button to part arm or 1st defense line enable to protect the perimeters of your home at night time before going to sleep. Please replace the battery within 2 years of usage or any time when it becomes less sensitive or has a shorter controlling distance. Adding & Cancelling Remote Controllers. To Add: Press_ SET + Password + ENT_then. _ 70 + ENT ENT the Learn light will appear solid red. Press any button on remote controller twice consecutively, the alarm host will beep in series and the Learn light flashes five times and then turns off to indicate the remote control has been successfully added. To Cancel: Press_ SET + Password + ENT_then. _ 71 + ENT ENT the alarm host will beep in series then the Learn light flashes once and then turns off to indicate the remote control has been successfully cancelled. Note: The alarm host can only learn 1 remote control at a time, a total of 8 remote controllers can be added to a host. Wireless Door/Window Sensor (SM-87B) * For Mounting Holes, please use screw (C) or adhesive sticker. (see page22) For Mounting Bracket, please use screw * (D). (Magnetic underlay mount use for uneven surface) (see page22) 9
13 Functions/Features: Mainly detect open/close states of doors and windows, generally set as a 1st Defense Line or perimeters. If any doors or windows are opened, it will transmit the alarm signal to notify the alarm host. Specifications: Operating power: 23A or 27A 12V Battery (Recommend: alkaline battery) Wireless Transmitting distance: 450ft (in open area) Service life: 2 years Alarm Distance: <4cm Installation and Usage Mount the magnet or smaller piece onto the door in a position of about 5~6ft above the ground to prevent any child(ren) from tampering. Use the included mounting bracket if the door and the door frame are un-even or not flush. Mount the emitting or larger piece onto the door frame, ensure the magnet piece and the emitting piece are even or flush. The spaces between the two should be less than 10mm in gap. Replace the battery if the red LED light flashes frequently. Adding and Cancelling Door/Window Sensor To Add: Press_ SET + Password + ENT_then. _ 70 + ENT+ XX + ENT The Learn light will appear solid red. Note: The XX indicate group number of the 1st defense zones, including zone 06 through zone 10. Triggers the Door/Window magnet twice consecutively, the alarm host will beep in series and the Learn light flashes five times and then turns off to indicate the magent door/ window sensor has been successfully added. To Cancel: Press_ SET + Password + ENT_then. _ 71 + ENT+ XX + ENT The alarm host will beep twice then the Learn light will flash once and then turns off to indicate the magnet door/ window sensor has been successfully cancelled. Note: The alarm host can only learn 1 wireless device (Magnet Door/Window Sensor) at a time, a total of 4 wireless devices (magnetic sensors) to a zone/group can be added. For example; for the 1st defense line, if 4 sensors were to be added to zone/group 06 through zone/group 10, it total 20 sensors in all. If 1 device is removed from a group that has 4 devices, then all 4 devices in the group will be automatically removed, and each device(s) will have to be added again to the alarm host. 10
14 Wireless Wide-Angle PIR Motion Sensor (SM-80) Please use screw * (E) to install the bracket (see page22) Functions/Features: Mainly monitor and control indoor stereoscopic spaces, generally set as a 2nd Defense Line. When human body enters the detection areas, the motion sensor will transmit the alarm signal to the alarm host. It is immune to pets; cats, dogs, etc that are less than 10KGS will not cause false alarm. 11 Specifications: Operating power: 9V Battery (Recommend: alkaline battery) Wireless Transmitting distance: 450ft (in open area) Service life: 2 years Detection Area: x10m
15 Installation and Usage Mount the bracket to a desired wall surface, location, or corner at a height of about 6ft to 7ft above the ground. Open the sensor cover and connect a 9VDC battery. Next, refers to the diagrams above to adjust and select the Jumper Line timer between 5S or 5MIN for the motion sensor to detect once every 5 seconds or the sensor to detect once every 5 minutes. Recommended to use 5S default setting for normal use. Skip To Add motion sensor below for newly added motion sensor before closing the sensor cover and proceed to the next step. Match the grooves of the sensor to the bracket and slide the motion sensor down from top to bottom to secure. Adjust the sensor to a proper angle and then slide the power switch located on the side to the ON position. The motion sensor takes 30 seconds to become active for operation (normal working state) after switching ON. A red light will flash for motion detection, a frequent green light flashing means it is time to replace the battery. Adding and Cancelling PIR Motion Sensor To Add: Press_ SET + Password + ENT_then. _ 70 + ENT+ XX + ENT The Learn light will appear solid red. Note: The XX indicate group number of the 2nd defense zones, including zone 11 through zone 15. Press the Learning Emitting Switch twice consecutively to trigger PIR sensor, the alarm host will beep in series, and the Learn light flashes five times and then turns off to indicate the PIR motion sensor has been successfully added. To Cancel: Press_ SET + Password + ENT_then. _ 71 + ENT+ XX + ENT The alarm host will beep twice then the Learn light flashes once and then turns off to indicate the PIR motion sensor has been successfully cancelled. Note: The alarm host can only learn 1 wireless device (Wireless Wide-Angle PIR Motion Sensor) at a time, a total of 4 wireless devices (PIR Motion Sensors) to a zone/group can be added. For example; for the 2st defense line, if 4 sensors were to be added to zone/group 11 through zone / group 15, it total 20 sensors in all. If 1 device is removed from a group that has 4 devices, then all 4 devices in the group will be automatically removed, and each device(s) will have to be added again to the alarm host. 12
16 Wireless Indoor Siren (SM-103W) Functions/ Features: Wireless receiving indoor alarm siren, spot alarm sound and flashes Plugs into wall outlets, for indoor use only. Specifications: Operating Power: VAC Wireless Receiving distance: 300 ft (In open area ) Siren Sound 105dB Installation and Usage: Plug the wireless indoor siren into a power outlet. Recommendated to install 4~5ft high from the ground. 13 Adding and Cancelling Indoor Siren To Add: After connecting the siren to the power outlet, press the Learning button located on the left side of the siren and the siren light will come on. Press the button on the alarm host (remote control not applicable) to sound off the sirens, then disarm by using the alarm host
17 keypad by pressing _ESC/Disarm + programming password + ENT_, the alarm host will beep twice to indicate the indoor siren has been successfully disarmed. The light on the siren will flash 5 times to indicate the indoor siren has been successfully added. To Cancel: After connecting the siren to the power outlet, press and hold the Learn button located on the left side of the siren for 5 seconds, the light on the siren will flash once to indicate the indoor siren has been successfully cancelled. Note: The alarm host can only learn 1 wireless device (Indoor Siren) at a time, multiple wireless sirens can be added to a host. When adding or cancelling wireless sirens, only operate using the alarm host keypad; do not use the remote controllers to disarm in the process. Wireless Smoke Alarm (SM-93, optional) * Please use screw (F) for mounting bracket (see page22) Functions/Features: Monitor and control indoor fire risks, for indoor use only, generally set as a 24 hour Defense Line. Replace the battery every 2 years (varies on usage). Usually installed to ceilings of living room, hallways, aisles, etc. 14
18 Specifications: Operating power: 9V Battery (Recommend: alkaline battery Wireless Transmitting distance: 300ft (in open area) Service life: 2 years Monitor volume: 480ft3 Adding and Cancelling Smoke Alarm To Add: Press_ SET + Password + ENT_then. _ 70 + ENT+ XX + ENT The Learn light will appear solid red. Note: The XX indicate group number of the 24 hour defense zones, including zone 01 through zone 05. Press the Test Button twice consecutively to trigger the smoke alarm sensor, the alarm host will beep in series, the Learn light will flash five times and then turns off to indicate the smoke alarm sensor has been successfully added. To Cancel: Press_ SET + Password + ENT_then. _ 71 + ENT+ XX + ENT The alarm host will beep twice, the Learn light flash once and then turns off to indicate the smoke alarm sensor has been successfully cancelled. Note: The alarm host can only learn 1 wireless device (Smoke Alarm Sensor) at a time, a total of 4 wireless devices (Sensors) to a zone/group can be added. If 1 device is removed from a group that has 4 devices, then all 4 devices in the group will be automatically removed, and each device(s) will have to be added again to the alarm host. Wireless Outdoor Siren (SM-103, optional) 15 * Please use screw (G) to mount. (see page22)
19 Functions/Features: Nice, exquisite and weatherproof. Micro-computer controller, steady performance and quality. Study up to 10 pieces to a host. Built - in rechargeable battery for backup, automatic switches between AC powers to DC power in cases of emergency outage. Low standby power consumption, low battery voltage LED detection, resumes charging automatically. Wall mount installation Specifications: Operating power: 110~240VAC_50Hz Static power consumption: 40 ma Working power consumption: 450 ma The maximum alarm sound duration with flash: 3 Minutes Receiving distance: 300ft (in open area) Built-in Rechargeable battery 6VDC 1300mA (up to 100 hours stand-by) Alarm Siren Sound 120dB IP51 Installation and usage Plug in the AC power to an outlet; press the green button to enable the backup battery located on the back side of the outdoor siren. Study the siren to the alarm host according to the activation and deactivation instructions below. Unplug the siren from the AC power plug after you finish studying and find a proper location (Outdoor/indoor) to mount it, then plug in the AC power. The alarm sound and red LED flash lasts up to 3 minutes if the alarm host is not disarmed within the 3 minutes. When the backup battery has a voltage that is equal to or less than 5VDC, the charging indicator (solid red) light will come on to represent charging status. The rechargeable battery takes approximately 20 hours to be fully charged and then the charging indicator light will turn off. Activating and deactivating Outdoor Siren To Activate: Siren: Connect the siren to an AC power outlet > press the red Study button located on the back of the siren > the red siren lights will turn ON. 16
20 Alarm Host: Press emergency button on the alarm host to sound off the alarm and then disarm the alarm by using the _ESC/Disarm + programming password + ENT_, the alarm host will beep twice to indicate the outdoor siren has been successfully disarmed The light on the siren will then flash 5 times to indicate the outdoor siren has been successfully added. Note: One siren can be studied at a time, up to 10 wireless alarm sirens to a host. To Deactivate: Press and hold the Study red button for 10 seconds, the siren will flash once to indicate the Outdoor siren has been successfully deactivated. Wireless Panic Button (SM-89, optional) * To mount, please remove the back cover and use screw (H). (see page 22) Functions/Features: Used for emergency panic, generally set as a 24 hour Defense Line. Placed under tables, beside bed whenever panic is needed. Replace battery every 2 years (varies on usage). Specifications: Operating power: 23A 12V Battery (Recommend : alkaline battery) Wireless Transmitting distance > 450ft (in open area) Service life: < 2 years 17
21 Installation and usage Installed in living rooms, bedsides, carry along, etc. For emergency use, scared away intruders; sends out emergency signal to alarm host to sound off the siren(s). This is a 24 hour standby zone for panic or emergency use only. Please change the battery when the signal distances become shorter or every 2 years. Adding and Cancelling Panic Button To Add: Press_ SET + Password + ENT_then. _ 70 + ENT+ XX + ENT The Learn light will appear solid red. Note: The XX indicate group number of the 24 hour defense zones, including zone 01 through zone 05. Press the Alarm button twice consecutively, the alarm host will beep in series, the Learn light will flashes five times and then turns off to indicate the panic button has been successfully added. To Cancel: Press_ SET + Password + ENT_then. _ 71 + ENT+ XX + ENT The alarm host will beep twice, the Learn light will flash once and then turns off to indicate the panic button has been successfully cancelled. Note: The alarm host can only learn 1 wireless device (Panic Button) at a time, a total of 4 wireless devices (Panic Buttons) to a zone/group can be added. If 1 device is removed from a group that has 4 devices, then all 4 devices in the group will be automatically removed, and each device(s) will have to be added again to the alarm host. 18
22 Air-Alarm1 Defense Zone Code Chart: Defense Zone Code Defense Zone Type Bypass Zone Delay Time to Alarm Compatible Accessories Remark 00 No No Wireless Remote Controller & Wireless Remote Control Keypad Up to 8 RC 1 to 5 24-hour Defense Line No No Yes (zone 11 6 to 10 1st Defense Line Yes to15) Wireless Smoke Alarm, Wireless Gas Alarm, & Panic button. Wireless Door Magnet & Wireless Curtain PIR Sensor Each defense zone supports up to 4 wireless devices. 11 to 15 2nd Defense Line Yes (zone 6 to 10) Yes Wireless Wide-Angle PIR Motion Sensor Manufacturer Wireless Default Setting: 19 Wireless Sensor Type The default Defense Zone Code Remote Control Wireless Door/ Window Sensor Wireless Wide- Angle PIR Motion Sensor Wireless Curtain PIR Sensor (N/A) Wireless Gas Alarm (N/A) Wireless Smoke Note : If after setup the alarm system becomes uncontrollable or abnormal; please remove or cancel all of the default setting of wireless devices such as the remote control, door/window sensor, wide-angle PIR motion sensor, smoke alarm and then add (re-program) them back into to a desired defense zone code Alarm Panic Button
23 Common Problems and Solutions Problems Possible Cause Solutions The alarm host sounded off immediately after connecting the power The alarm host cannot record or partially records Repeatedly receiving the alarm telephone The alarm host does not sound the alarm after the detector triggered the alarm in armed mode. The PIR motion sensor does not work The telephone incoming line has not been connected, poor connection or short circuit. The record switch is not turned on. The Record buttons not pressed down and held while attempting to record, or not held down all the way. No one picked up the alarm calls or failure to press the * star button to end/ drop the call. 1. The wireless devices may not have synchronized with the alarm host. 2. The dwell time for Entry Delay or Exit Delay has not been reached. Weak battery power, not switched on, or the PIR motion detector is in the power-down mode Double check, test and secure the incoming telephone line or use a standard phone to test the line to ensure working status. Slide the record switch to the ON position; Securely press and hold down the RECORD button during recording. Speak up close to the rear speaker of the host. After answering the alarm phone calls and hearing the recorded message: please advanced to page 5 (Telephone Alarm) of this user s manual as a reference to try to resolve this problem, or simply press the * star button to end the call. 1. In Home mode, make sure the sensor or wireless devices triggering is not in the 2nd Defense Line. Simply cancel the wireless devices and add them in again to synchronize with the host. 2. Ensure the sensor detectors are not active within the system setup Entry Delay Time or Exit Delay Time, default delay time is 40 seconds Open the sensor shell to install the battery and slide the power switch to On. Power down mode may be in affect: 5S : detect once every 5 seconds 5MIN : detect once every 5 minutes, please refers to the user s manual for PIR setup. 20
24 The detecting distance of PIR motion sensor gets shorter The ambient temperature in the detecting area is too high. When the ambient temperature in the detecting area exceeds the human body temperature, the detecting distance will get shorter, it s normal. The alarm host does not alarm after the new added wireless detector is triggered. Failed to follow the operation instruction of Adding and Cancelling sensors/ devices of newly added wireless sensor(s) Follow the operation instruction of Adding and Cancelling to activate the new wireless sensor(s) The PIR motion sensor flashes frequently in green. Battery is drained or low. Replace with new battery of the same voltage specification. The door/window sensor indicator flashes frequently in green after alarming. Battery is drained or low. Replace with new battery of the same voltage specification. The distance of the remote controller gets shorter. Battery is drained or low. Replace with new batter of the same voltage specification. 21
25 Daily Maintenance and Care This alarm system is hi-tech with outstanding design functionality and sophisticated product features which should be used carefully. To make the alarm system operable long term and prolong the service life; the following are strongly recommended: 1. Install the alarm system and alarm host in dry and well ventilated locations. 2. Do not put the alarm host or any wireless sensors in extreme cold, extreme heat or excessively dusty places. This is to prevent shortened lifetime of the products, including the internal electronic parts and the plastic housings from being exposed to harsh conditions. 3. Do not install the wireless alarm system in low, easy to reach, and exposed places to prevent the children from tampering with or thieves easy access. 4. Regular scheduled testing is necessary to help prevent system failures and resolve problems in time. 5. Check batteries in all wireless sensors and replace them as needed to ensure normal operation. 6. Power off and remove all batteries from all wireless system before storing them on shelves. Accessories: Add-on(optional): Adhesive sticker 22
26 Air-Alarm1 Frequently Asked Questions Q1: If I have an answering machine turned on will I be able to call in to arm/disarm the host? A1: No, please be sure to turn off the answering machine on the telephone for the alarm host to be able to receive incoming calls. The fact that most answering machines will answer within 6 or 7 rings and our Air-Alarm1 system requires about 15 seconds in order to receive incoming signals and allow arm/disarm, the answering machine will pick up the signal before Air-Alarm1 host if the answering machine is not turned off while away from home. Q2: How can I tell if my Air-Alarm1 is correctly armed before leaving home? A2: Please make sure to arm the alarm host and check to see if the red LED light comes on armed, once certain then leave home. From the moment it is armed, there will be 40 seconds to 1 minute delay time to leave home depending on the dwell time setup. Q3: My siren is not loud enough; I could barely hear them when I am standing outside? A3: Install the siren closer to the windows, open space, add more indoor sirens or add an outdoor siren for louder siren sound. Q4: Do the antennas on the Air-Alarm1 system have to be extended outward for normal use? A4: No, extending the antennas outward may not be necessary if the area of installation has adequate reception. However, in an area with weak reception, extending the antenna will provide maximum performance. Q5: Does the Air-Alarm1 support dial-in to arm/disarm if it is installed behind a multiple line digital phone system? A5: No. Currently Air-Alarm1 can only function through a dedicated phone line, such as; a PSTN (Public Switched Telephone Line), home phone line (aka. POTS - plain old telephone service). Air-Alarm1 do not support VOIP (Voice Over Internet Protocol) digital telephone service. Q6: My Air-Alarm Host intermittently sounds off the alarm during disarm mode? A6: Please switch the power on the left side of the Alarm Host to the OFF position and disconnect the power jack from the Host. Wait for several minutes and then plug the power jack back into the Alarm Host and switch the power to the ON position. Q7:The Air-Alarm was working and now the wireless devices will not trigger the Alarm Host? A7: Please follow the To Add: instructions for each device and add all the wireless devices back to allow synchronization with the Alarm Host. Q8: When I switch on my PIR motion sensor it continuously triggers the Alarm Host even when the Host is not armed? A8: Turn OFF the PIR sensor, open the cover of the PIR sensor, place the PIR sensor towards a wall to avoid fault triggering, reference pg12 of the manual To Add: the PIR sensor again to zone 11 (default zone for PIR sensor). Q9: Do I need to add each of the wireless devices that comes with the kit to the Alarm Host? A9: No, each wireless device inside each Air-Alarm kits is already added by default. 23
27 Q10: How can I clear the enlisted telephone numbers from the list? A10: To clear the enlisted telephone numbers press; SET+password+ENT+01 (01~05 group no.)+ent+ent Or simply add the enlisted telephone numbers to the same group to override the old. Q11: My Alarm Host keeps on triggering during in coming and out going calls? A11: Please disable the Telephone Disconnection Alarm by entering the following command; SET+password+ENT+60+ENT Q12: How does SM-80 PIR Motion Sensor work and why is it not sensitive enough? Q12: SM-80 PIR Motion Sensor areas of detection is 110 degree, 30x30ft. It is immune to animals that are equal to or less than 10kgs in weight, ie. dogs, cats, etc. 1)SM-80 can become less sensitive if the battery becomes weak; replace new 9VDC battery. 2)Try removing the sensor by following the To Cancel procedure in the user s manual and then follow the To Add and add it into another zone of the Alarm Host. 3)Power cycle both PIR motion sensor and Alarm Host. Here is some examples of testing methods that is not recommended for SM-80 PIR Motion Sensor:- Shaking one hand in the front of the PIR Motion Sensor. It might not sense well because the IR radiation from one hand may be too small to detect.- Moving an object (none temperature object), like a stick in the front of the PIR Motion Sensor. It may not sense because sticks in general does not emit IR radiation.- Moving out of the detection areas. 24
28
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
Wireless Home Security System Product Manual (Model #80355)
Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.
WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
PiSector Home security systems
PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please
Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.
Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,
PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
DC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
GSM ALARM SYSTEM USER MANUAL
GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy
Auto Dialer. Manual E-921APQ E-921GPQ
Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
Intruder Alarm System
Intruder Alarm System GSM & PSTN Wireless and Wired Touch Model 2013-01 V1.0.0 Statment This equipment must be installed and used in strict accordance with the instructions given in this user documentation.
HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15
HomeSafe-Basic VT-PS99E User s Manual PSTN Home Alarm System Page: 1 / 15 Table of Contents 1. Product Overview:... 3 2. Main Functions & Features... 3 3. For Your Safety... 4 4. VT-PS99E Characteristics...
WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054
WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the
Wireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
PSTN Home Alarm System
PSTN Home Alarm System User Manual Model: PST-TEL99E Please read this user guide carefully before operation and installation. Contents 1. Product Overview... - 3-2. Main Function & Features... - 3-3. For
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
GSM Home Alarm System User Manual. http://www.usmartbuy.com
GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance
User Manual for GSM / LED Touch Keypad Wireless Intelligent Home Alarm System
User Manual for GSM / LED Touch Keypad Wireless Intelligent Home Alarm System I. Foreword Thank you for purchasing and using GSM / LED touch keypad wireless intelligent home alarm system. This is a Hi-performance
Six-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets
LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions
Wireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
Business/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :
Intelligent GSM Auto-Dial Alarm System
Auto-dial Alarm System Intelligent GSM Auto-Dial Alarm System Profile For a better understanding of this product, please read this user manual thoroughly before using it. 2013.2.V1.0 Auto-dial Alarm System
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
PiSector Land Line Auto Dial Professional Wireless Alarm System
PiSector Land Line Auto Dial Professional Wireless Alarm System User Manual ( PS03 ) Read manual fully before use. PiSector Inc., USA, www.pisector.com Welcome to PiSECTOR Thank you for choosing PiSECTOR.
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL. GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System
GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System SECURE YOUR HOME AND BUSINESS Printed in Shenzhen RE: G60-GSM-August-2013 Key Features Smart touch
PRODUCT WARRANTY. Page 20
PRODUCT WARRANTY Manufactured equipment is warranted to be free from defects in material and workmanship for a period of twelve (12) months from date of manufacture as indicated by the date stamp and/or
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
MOBILE CALL GSM alarm system
MOBILE CALL GSM alarm system User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Catalogue: Function Introduction 2 SMS Number
Hills wireless security alarm DIY range
Hills wireless security alarm DIY range EASY TO INSTALL DIY system PEACE OF MIND Receive SMS/calls when alarm is armed INTERACTIVE Arm and disarm by SMS or via smartphone app Control your alarm via smart
Intelligent GSM Auto-dial Alarm System User s Manual
Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]
CAD-05 Kit GSM Auto Dialer. Owner s Manual
CAD-05 Kit GSM Auto Dialer Owner s Manual CAD-05 Kit Manual.indd 1 Warnings: This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This
LCD -based Intelligent Burglar Alarm System. User Guide. Ver 2.0
LCD -based Intelligent Burglar Alarm System User Guide Ver 2.0 Table of Content 1. Introduction... 2 1.1 General Description... 3 1.2 System Features... 3 2. Anatomy of the LCD-based Intelligence Burglar
Total Protection Alarm System
www.skylinkhome.com Total Protection Alarm System MODEL: SC-10 101A073-001 AUG, 2005. CUSTOMER SERVICE 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel : (800) 304-1187 Fax : (800) 286-1320 Email
CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual
SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL
User Manual CN2HK LIMITED. Complete Wireless Home Alarm Security System (CK-8806) ENG. Please read this manual before operating this product.
CN2HK LIMITED Complete Wireless Home Alarm Security System (CK-8806) User Manual Please read this manual before operating this product. After you finish reading this manual, store it in a safe place for
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
User Guide. Model: MAS-WA-SYS
User Guide Model: MAS-WA-SYS CONTENTS Section : Getting started... 4. General system overview. Introduction to the system.3 Items included with the system.4 Introduction to the Wireless Alarm Panel.5 Introduction
HWS100 Wireless Home Security System
4902000 HWS100 Wireless Home Security System Owner s Manual WARNING: Security system devices cannot compensate for loss of life or property. Company is not responsible for any loss or intrusion. CONTENTS
STATUS POWER MONITOR ALARM SOS DISARM
STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings
Solution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES
Residential & Commercial Alarm Systems by Gross Security, LLC
151 Main Street, Suite, 1, Get these great features with a landline or cellular alarm system from Gross Security, LLC Alarm system prices include installation Base system includes one hour of training
PhoneWatch Smart Security System User Manual - Domonial
PW0002 10/13 Customer Support: 1850 753 753 PhoneWatch Ltd., Unit 3/4, Sandyford Park, Burton Hall Rd, Sandyford Industrial Estate, Dublin 18. Email: [email protected] PhoneWatch Smart Security System
User Manual for GSM / LED Touch Keypad Wireless Intelligent Home Alarm System
User Manual for GSM / LED Touch Keypad Wireless Intelligent Home Alarm System I. Foreword Thank you for purchasing and using GSM / LED touch keypad wireless intelligent home alarm system. This is a Hi-performance
Automatic Telephone Dialer TD-101(W)
Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages
GE Concord 4 Quick User Guide
GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is there a flashing
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
Home alarm system. User s manual. Profile To better understand this product, please read the user s manual carefully before using.
Home alarm system User s manual Profile To better understand this product, please read the user s manual carefully before using. Features; 1. 1-99 LED wireless defense zone, with digital number to show
User s manual for GSM+PSTN Touch Screen Wireless Alarm System
User s manual for GSM+PSTN Touch Screen Wireless Alarm System I. Foreword Thank you for purchasing and using GSM/PSTN LCD touch screen wireless home alarm system. This is a Hi-tech household security product.
PiSector GSM Cellular Wireless Alarm System
PiSector GSM Cellular Wireless Alarm System User Manual ( GS08 ) Read manual fully before use. PiSector Inc., USA, www.pisector.com Welcome to PiSECTOR Thank you for choosing PiSECTOR. Everyone at PiSECTOR
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions
SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL
SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL PINKERTON Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS...1 INSTALLATION OF THE SECURITY SYSTEM...2 COMMISSIONING
User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd
User Manual GSM Alarm System All rights reserved by Delta Security Co., Ltd Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today
Voice Dialer System & Power Monitor VD-5100-SM
Custom Design Innovative Technologies in Custom Electronic Design & Manufacuturing General Description The VD-5100-SM Voice Dialer monitors an external dry contact such as a motion detector and power status.
Total Protection Alarm System
www.skylinkhome.com Total Protection Alarm System MODEL: SC-1000W If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :
Safe Health Guarder User Manual
Safe Health Guarder User Manual Contents Tips: Please read through this user manual before installation so as to operate properly. Please keep well of the user manual for further reference. For properly
GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE. Please read it carefully before installation and operation
GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE Please read it carefully before installation and operation Your New Diamond Designs Alarm works with a GSM SimCard via the cellular phone,system to call up
NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)
NetworX Series NX- 4/8 Code Pad User Manual (Australian Version) Table Of Contents Code Pad Diagram... Inside Front Glossary of Terms...2 Understanding the Code Pad lights...3 Code Pad Tones...4 Fully
Users Guide to Keypad Functions
Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &
466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide
) *(6HFXULW\ 466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
o^c a (fg 1) Telephone Line Socket ( flcg. 2b ) ) fig. 2a ) TeiePhone b ^^I r DC Adaptor
INTRODUCTION Our jnique passive in`raroc ^ys,e^ii conccotrates on the protected area you select. Whenever the unit is set at ARMED, the motion detector will concentrate on the protected area. Once there
EM8610 e-alarm GSM Alarm System Starter Kit
EM8610 e-alarm GSM Alarm System Starter Kit 2 ENGLISH EM8610 - GSM Alarm system Starter Kit Table of contents 1.0 Introduction... 4 1.1 Packing contents... 4 2.0 Explanation of the control panel... 5 2.1
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
WITURA CORPORATION SDN BHD
WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:
Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location
45131 Wireless Alarm System Window/Door Sensor User s Manual Choice ALERT Control all Sensors & accessories from one location Table of Contents Important Safeguards 4 Introduction 5 Installation 6 Assigning
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
SEC-ALARM200 WIRELESS ALARM SYSTEM
SEC-ALARM200 WIRELESS ALARM SYSTEM - 1 - Safety precautions: CAUTION To reduce risk of electric shock, RISK OF ELECTRIC SHOCK this product should ONLY be DO NOT OPEN opened by an authorized technician
TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0
TUTA B12 GSM REMOTE CAMERA User Manual Manual version 3.0 TUTA Series GSM Remote Camera Thank you for purchasing the TUTA camera. This camera is a remotely controlled image-capturing device consisting
GSM home alarm system s manual
GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.
Ademco Vista-20P/First Alert FA-168C Basic Commands
Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,
GE Simon XT Quick User Guide
GE Simon XT Quick User Guide GE Simon XT Quick User Guide Page 1 Before Calling Is the keypad beeping? Press STATUS. This will silence the beeping and let you know where the trouble is. Is there a flashing
Passive Infrared Sensor Alarm
49-329.fm Page 1 Wednesday, August 18, 1999 4:23 PM Cat. No. 49-329 OWNER S MANUAL Please read before using this equipment. Passive Infrared Sensor Alarm with Keychain Remote 49-329.fm Page 2 Wednesday,
Business/Home GSM Alarm Systems
Business/Home GSM Alarm Systems Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Ⅰ.General information: 1.
GSM Home Alarm system. User Guide
GSM Home Alarm system User Guide Version 2.0 Page 1 of 21 TABLE OF CONTENT System Overview...3 Introduction...3 Features...3 About the Front Panel...4 About the Back Panel...5 General Operation...6 AWAY
ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1
ITC-BTTN Cellular Bluetooth Gateway Owner s Manual 1 2 Table of Contents Introduction...3 Package Contents...3 XLink Connections Diagram...4 Setup...5 Pairing your Bluetooth Cell Phone to the XLink...6
GSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
Emergency Dialer DIAL-ALERT. English MODEL : AD-433S. www.skylinkhome.com
www.skylinkhome.com Emergency Dialer English DIAL-ALERT TM MODEL : AD-433S 101A320 JUNE, 2004 CUSTOMER SERVICE 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel : (800) 304-1187 Fax : (800) 286-1320
1pcs. 1pcs. 2pcs 1pcs 1pcs 2pcs
Home security alarm system LX-HS06 Instruction Brief introduction LX-HS06 is a set of entirely new English home security alarm system, it uses advanced MCU control and SMD technology. it innovate multiple
Security GSM Alarm System
KONLEN TECHNOLOGY LIMITED Website: www.konlen.com Add:, 3/F, Building5, Kaijieda Industry Zone, Huachang Road, Longhua, Shenzhen China Tel: +86-(0)755-29709632 E-mail: [email protected] [email protected]
Home Alarm System User s Manual. Home Alarm System User Manual
Home Alarm System User s Manual Home Alarm System User Manual Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today and take the
Iphone & Android App Smart GSM Home Alarm System
Iphone & Android App Smart GSM Home Alarm System PST-GA242Q User Guide Version V14.3 Dear User, Thanks for selecting the intelligent alarm system. Please read through this guide before installation so
PC Tab Security System INSTRUCTION MANUAL
PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive
Business/Home GSM. Alarm System(III) Installation and Users guide
Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment
Basic Alarm BD-5000. A. What You Will Need: 1. One 9-volt alkaline or lithium battery (not included). 2. Phillips screwdriver (not included) 2
Basic Alarm BD-5000 1 Model BD-5000 Thank you for purchasing the Basic Alarm BD-5000. If you should ever have any questions or concerns about this product, feel free to contact us. Our phone number, web
IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay
Distress alert system. User Manual DAS1100
DAS1100 Distress alert system Alerts friends and family at the press of a button Allows independence while keeping you in touch Helps you maintain your active lifestyle User Manual Keep this manual safe
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
AD-01 Slave Auto Dialer. Owner s Manual
AD-01 Slave Auto Dialer Owner s Manual AD-01 Slave Manual.indd 1 10/15/2009 10:20:44 AM 2 AD-01 Slave Manual.indd 2 10/15/2009 10:20:44 AM Features: Programmable entry/exit delay time; select up to 9 (32
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
Car Alarm Series 2 B 2 Buttons
Car Alarm Series 2 B 2 Buttons G22 SE (External - Shock Sensor) Version 3 Software 67 Plus www.geniuscaralarm.com 21 CAR ALARM GENIUS Series 2B 2 Buttons - G22 Se (External Shock Sensor) Module controlled
