Install NEMA 4X enclosure for the Sievers * InnovOx Online TOC Analyzer

Size: px
Start display at page:

Download "Install NEMA 4X enclosure for the Sievers * InnovOx Online TOC Analyzer"

Transcription

1 6060 Spine Road Boulder, CO USA USA Europe Worldwide Install NEMA 4X enclosure for the Sievers * InnovOx Online TOC Analyzer Introduction Purpose: To install the NEMA 4x enclosure for the Sievers InnovOx Online TOC Analyzer. Scope: This procedure describes how to install the NEMA 4X Enclosure and how to install the 2 or 5- stream InnovOx Online TOC Analyzer into the NEMA 4X Enclosure. The Enclosure is designed for use in indoor, non-hazardous locations. The Enclosure protects the InnovOx Online TOC Analyzer against falling dirt, dust, splashing and hose-directed water, and corrosion. Safety: The NEMA 4X Enclosure weighs approximately 150 lb without the Analyzer installed in it. Lift the Enclosure only using equipment designed to safely support that weight. Specifications: The NEMA 4X accessory consists of a corrosion-resistant enclosure fitted with access panels, a vortex cooler assembly, and NEMA 4X-rated pass-through fittings for fluidic and electrical connections to the Analyzer. The following drawings show the locations of the pass-throughs, vortex cooler, and related hardware. Specifications for the Enclosure are provided: Dimensions (H x W x D): Weight: Enclosure material: Ambient temperature limits: Mounting: Environment: 53.2 in. x 39.4 in. x 25.3 in. (135 cm x 100 cm x 64.3 cm) Without Analyzer or vortex cooler: 150 lb (68.0 kg) With Analyzer and vortex cooler: 235 lb (107 kg) Fiberglass-reinforced polyester F (10 to 40 C) Wall mounted, ten 5/16 diameter fasteners Indoors, non-hazardous, not in direct sunlight Vortex cooler compressed air: Oil-free, up to 25 SCFM (0.012 m 3 s -1 ) 90 to 100 psig (620 to 689 kpa) Max. Temperature: 110 F (43 C) Vortex cooler filter element: Air line for vortex cooler: in. (5 μm), non-coalescing If length < 30 ft: 3/8 schedule 40 pipe If length 30 ft: 1/2 schedule 40 pipe * Sievers is a trademark of General Electric Company and may be registered in one or more countries. GE Analytical Instruments, Inc. 2010J Page 1 of 24 DIN Rev. B

2 Control (Signal) Check Standard Sample # 1 thru #5 Air to Filter Panel: #1 thru #5 Level Sensors: Check Standard Dilution Water Oxidizer Acid Reagents: Dilution Water Acid Oxidizer Left Side View GE Analytical Instruments, Inc. 2010J Page 2 of 24 DIN Rev.B

3 Filter Housing Compressed Air for Vortex Cooler AC Inlet, ½ NPT Vortex Cooler Carrier Gas Right-Side View GE Analytical Instruments, Inc. 2010J Page 3 of 24 DIN Rev.B

4 Drain for Analyzer Enclosure Drains for NEMA 4X Enclosure Waste 2X Sample #1 thru #5 Drains. From sample cup Bottom View Materials NEMA 4X Enclosure NEMA 4X Accessory Kit: (2) Mount Brackets (clamps) (6) 5/16-18 Nuts (mount clamps to instrument) (4) x 2 L Screws (secure instrument to back panel) (4) ½ Conduit Elbows (2) 8 Flex Conduit Pieces (1) 360 of 3/8 O.D. Clear PVC Tube (drains) 3/8 NPT Tube Kit for Vortex Cooler Air Inlet Includes 2 straight pipe couplings, 1 90deg. Elbow, & 2 hose clamps. (2) Large Drain Fittings and Nuts (For ¾ O.D. Tubing) (8) Smaller Drains Fittings and Nuts (for 3/8 O.D. Tubing) (15) ¼ Drain Plugs (For sample & drain ports) GE Analytical Instruments, Inc. 2010J Page 4 of 24 DIN Rev.B

5 (5) 5/32 Drain Plugs (For filter Panel Ports) (1) Vortex Cooler with instructions and accessories (Cold Air Duct Tubing & Muffler) Items provided by user: Tools: Channel-Lock Pliers, Straight-Slot Screwdriver, Adjustable Wrench, Portable Drill and Drill Bits, Tape Measure Temporary platform for the Enclosure that is capable of safely supporting 150 lb. Hardware for mounting the Enclosure on a wall. The hardware should be selected based on sitespecific circumstances, but it must accept a 5/16 diameter fastener. Ten fasteners are recommended; in total, the mounting hardware must be able to support four times the weight of the Enclosure and Analyzer (i.e., 940 lb). Compressed air line with 3/8 NPT Male fitting for connection to filter housing Carrier gas line, 1/4 OD polyethylene or polypropylene tubing. Oil-free compressed air having a pressure from 90 to 100 psig and a temperature no greater than 110 F (43 C). The Vortex cooler requires up to 25 SCFM of compressed air. Power and signal lines in grounded metal conduit. See the InnovOx Online TOC Analyzer Operation and Maintenance Manual for details. Sample lines and drain for excess sample and Analyzer waste. See the InnovOx Online TOC Analyzer Operation and Maintenance Manual for details. Procedures A. Select a location for the NEMA 4X Enclosure and the Analyzer. B. Unpack the NEMA 4X Enclosure and prepare for installation. C. Mount the NEMA 4X Enclosure. D. Install Additional Enclosure Equipment. E. Install the InnovOx 2 or 5 Stream TOC Analyzer into the NEMA 4X Enclosure. F. Connect AC Power and Control Signals. G. Install Vortex Cooler H. Install Fail-Safe Level Sensors if so equipped. I. Install Remaining Fluidic Connections J. Finish Installation GE Analytical Instruments, Inc. 2010J Page 5 of 24 DIN Rev.B

6 A. Select a Location for the NEMA 4X Enclosure and the Analyzer 1. Place the NEMA 4X Enclosure in a non-hazardous location indoors, away from direct sunlight and exposure to extreme temperatures. The temperature must not be less than 50 F (10 C) or greater than 104 F (40 C). 2. A drain or other receptacle must be nearby to receive excess sample and acidic wastewater produced by the Analyzer. 3. The location must provide space for the Enclosure and the clearance around the Enclosure, as shown in the figures below. GE Analytical Instruments, Inc. 2010J Page 6 of 24 DIN Rev.B

7 GE Analytical Instruments, Inc. 2010J Page 7 of 24 DIN Rev.B

8 B. Unpack the NEMA 4X Enclosure and Prepare for Installation 1. Remove the NEMA 4X enclosure from its packaging. Check for damage. The enclosure will have most of the passthroughs already installed. 2. Place the NEMA 4X Enclosure on the platform that is capable of safely supporting 150 lb. This provides room for attachment of mounting brackets to the bottom of the Enclosure. (See Steps 3 and 4.) Platform GE Analytical Instruments, Inc. 2010J Page 8 of 24 DIN Rev.B

9 3. Install the 5 large stainless steel brackets, which are included in the accessory kit. One is already installed over the left side cover. The brackets slide into the enclosure between the 2 small marks on the back lip of the enclosure. Install 2 on the right side, 1 on the left side, and 2 on the bottom. 4. Secure the brackets using the plastic clips provided. The clips slide over the bracket and snap into place, keeping the brackets from slipping out of the Enclosure lip. GE Analytical Instruments, Inc. 2010J Page 9 of 24 DIN Rev.B

10 C. Mount the NEMA 4X Enclosure 1. For easier installation (optional), remove Enclosure door by pulling upper and lower pins (8 total) on hinges as far as allowed. 2. Mark the wall for location of the mounting hardware per the figure. GE Analytical Instruments, Inc. 2010J Page 10 of 24 DIN Rev.B

11 3. Use 5/16 diameter mounting hardware to affix the Enclosure to the wall. All 6 brackets must be used. The fasteners must be capable of supporting four times the weight of the Enclosure and Analyzer (i.e., 940 lbs). 4. This picture is for reference only. The application shown is in ½ drywall with appropriate fasteners. 5. The bottom brackets are attached using the center hole and a 5/16 diameter fastener. Bottom brackets are on center. Use appropriate anchors for wall type with a 5/16 diameter fastener. GE Analytical Instruments, Inc. 2010J Page 11 of 24 DIN Rev.B

12 D. Install Additional Enclosure Equipment 1. Install the 10 NEMA 4X pass-throughs that fit into the bottom of the Enclosure. All 10 pass-throughs are in the accessory kit. An interior view of the bottom of the Enclosure is provided at the right, showing the pass-throughs installed. Any pass-through that will not have a tube must have a plug installed. Waste 2x Sample 1 thru 5 Drain. From sample block Analyzer Enclosure Drain Drain for NEMA 4X Enclosure 2. You may find it convenient to install the 3/8 OD clear tubing through the 2 or 5 NEMA 4X pass-throughs for Samples #1 thru #5 (depending on model) before installing those pass-throughs in the Enclosure. 3. If you plan to install the two tubes for the cabinet drains to the fittings for the NEMA 4X Enclosure, make sure that the tube does not extend above the fitting. See the figure on the right. 4. If you do not plan to add the two tubes to the cabinet drain fittings for the NEMA 4X Enclosure, insert 1/4 diameter plugs into the fittings. Ensure drain tubing does not extend above fitting GE Analytical Instruments, Inc. 2010J Page 12 of 24 DIN Rev.B

13 5. Install the 2 large (for 3/4 OD drain tubing) fittings in the position marked Waste in the figure shown in Step 1. E. Install the InnovOx 2-Stream TOC Analyzer into the NEMA 4X Enclosure. 1. Before installing the InnovOx 2 or 5 Stream TOC Analyzer, refer to the Operations and Maintenance manual (or the Quick-Start Guide), as well as the Installation Drawing, for proper installation procedure. GE Analytical Instruments, Inc. 2010J Page 13 of 24 DIN Rev.B

14 2. Attach one mounting bracket on the top of the Analyzer, with the bracket facing to the rear. The bracket is fastened using three 5/16-18 flange nuts provided in the accessories kit. 3. Attach a second mounting bracket on the bottom of the Analyzer, with the bracket facing the rear. This bracket also is fastened using three 5/16-18 flange nuts. GE Analytical Instruments, Inc. 2010J Page 14 of 24 DIN Rev.B

15 4. The brackets installed in Step 3 fit over the metal bars located on the rear panel inside the NEMA 4X Enclosure. Metal Bars 5. Insert the Analyzer into the Enclosure. Then lift the Analyzer onto the metal bars. Use the access panels on the right and/or left sides of the Enclosure to aid in lifting the Analyzer. AT LEAST TWO PERSONS ARE REQUIRED TO MOVE THE ANALYZER. GE Analytical Instruments, Inc. 2010J Page 15 of 24 DIN Rev.B

16 F. Connect AC Power and Control Signals. ALL ELECTRICAL INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED ELECTRICIAN 1. On right side, run hard conduit to the AC Inlet connector (1/2 NPT fitting) on the right side of the NEMA 4X Enclosure. AC In 2. Install the 8 piece of conduit, and 2 90 o elbows, inside the NEMA 4X Enclosure to the Analyzer. 3. Repeat Steps 1-2 on the left side of the Enclosure to provide conduit for the Control connections. Input/Output cables will be connected to the Analyzer through this conduit. For details on making electrical connections to the Analyzer, refer to the Operations and Maintenance Manual for the InnovOx Online TOC Analyzer. Use the access panels on the sides and top of the Enclosure for access to the Analyzer s top panel and the electrical interfaces inside it. G. Install Vortex Cooler GE Analytical Instruments, Inc. 2010J Page 16 of 24 DIN Rev.B

17 1. Unpack the Vortex Cooler and refer to its Operations and Safety Instructions. Vortex Cooler 2. Attach the air inlet fittings to the Vortex Cooler as shown, using Teflon tape on all joints. Take 3/8 NPT pipe fitting with attached 90 o elbow, and screw it into fitting on Vortex Cooler. 3. Attach the 5-micron filter housing onto the elbow. Filter Housing 4. Remove spanner nut from Vortex Cooler. GE Analytical Instruments, Inc. 2010J Page 17 of 24 DIN Rev.B

18 5. Place Vortex Cooler in large hole on upper-right side of NEMA 4X Enclosure. Ensure that Vortex Cooler is oriented with the air inlet on the top. Air Inlet 6. Replace and tighten spanner nut until it is finger-tight, plus ¼ turn. 7. The properly installed Vortex Cooler assembly is displayed in the pictures on the right. Warning: When Operating, the sheet metal on the Vortex Cooler unit is hot. Do not touch. GE Analytical Instruments, Inc. 2010J Page 18 of 24 DIN Rev.B

19 8. Install muffler by adhering it to the interior of the Enclosure on the right side, approximately 8-12 below the Vortex Cooler. GE Analytical Instruments, Inc. 2010J Page 19 of 24 DIN Rev.B

20 9. Install Cold Air Duct tubing and hose clamp by pushing onto threaded fitting of Vortex Cooler. Tighten hose clamp. 10. Push the other end of the tube onto the muffler barb. 11. Push the remaining Cold Air Duct tubing onto the second muffler barb. Hose clamp GE Analytical Instruments, Inc. 2010J Page 20 of 24 DIN Rev.B

21 12. This second tube can be arranged one of two ways to distribute cold air inside the Enclosure: The tube can be left unplugged, so that the cold air exits the tube entirely at the end opposite from the muffler. If this approach is selected, ensure that the end of the tube is not pointed directly at the Analyzer. The tube can be made into a diffuser by drilling at least sixteen 1/8 diameter holes in it. Then the end of the tube is plugged as shown at the right. 13. Use the provided adhesive clips to mount the tubing to the walls of the enclosure. GE Analytical Instruments, Inc. 2010J Page 21 of 24 DIN Rev.B

22 H. Install Fail-Safe Level Sensors 1. For Analyzers fitted with the Fail-Safe Accessory: Install Level Sensor cables by pushing cables through pass-throughs on the left side of the Enclosure and the left side of the Analyzer. 2. Inside the Analyzer, attach the grounding wire on each cable to the grounding screw provided. 3. Attach float cables to proper connectors inside the Analyzer as follows: Check standard: LS1 connector Acid: LS2 connector Oxidizer: LS3 connector Dilution water: LS4 connector GE Analytical Instruments, Inc. 2010J Page 22 of 24 DIN Rev.B

23 4. Secure the 4 cables to both cable straps inside the Analyzer, and then snap straps close. I. Install Remaining Fluidic Connections 1. Refer to the Sievers InnovOx Online TOC Operation and Maintenance Manual to determine the correct fluidic connections for your Analyzer and application. 2. Extend the tube for each fluidic connection required for your Analyzer through the corresponding pass-through on the NEMA 4X Enclosure. The locations of these pass-throughs are shown in the figures on pages 2 and 3. GE Analytical Instruments, Inc. 2010J Page 23 of 24 DIN Rev.B

24 3. Plug any unused pass-through with plugs supplied in the accessories kit. For example, if the Analyzer will only monitor one sample stream, plug the sample #2 thru #5 inlets on the left side of the Analyzer and the Sample #2 thru #5 drains on the bottom. 4. If the Analyzer is not fitted with 2 to 5 Filter Panels, plug the unused Air-to-Filter Panel pass-through(s) of the left side of the Enclosure. 5. If the Analyzer is not fitted with the Fail- Safe Accessory, plug the pass-throughs for the Level Sensors on the left side of the Enclosure. J. Finish Installation 1. On the exterior of the Enclosure, tighten each pass-through around the tube (or cable) that is inserted in it. Finger-tighten the outer nut around the tube/cable. 2. Plug any pass-through on the Enclosure that does not have a tube or cable in it. 3. Place all of the drain tubes into their appropriate drains or receptacles. 4. Remove plastic around the NEMA 4X Enclosure. 5. Dispose of removed materials according to local regulations. 6. Complete the installation procedures in the Sievers InnovOx Online TOC Analyzer Operation and Maintenance Manual. 7. If a Filter Panel is used with the Analyzer, complete the relevant installation procedures. Refer to the GE InnovOx Filter Panel Operation and Maintenance Manual. 8. Turn on the compressed air to the Vortex Cooler. 9. Follow the Start-Up procedure in the Sievers InnovOx Online TOC Analyzer Operation and Maintenance Manual. 10. Close and secure the front door and all access panels on the NEMA 4X Enclosure. GE Analytical Instruments, Inc. 2010J Page 24 of 24 DIN Rev.B

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Installation Instructions

Installation Instructions Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply

More information

Installation Instructions

Installation Instructions Installation Instructions One-Piece Deep Wall Sleeve For Use with Packaged Terminal Units Please read these instructions completely before attempting installation. NOTE: Ensure that the unit is only installed

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

Installation Instructions 4508 4508S

Installation Instructions 4508 4508S SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and

More information

Rack installation instructions

Rack installation instructions Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100

More information

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools: Guide for Modified Assembly: Lightning McQueen By: Collin Patterson, University of Delaware Materials and Tools: PVC o 40 inches of 1 in diameter PVC o 25 inches of ¾ in PVC o 4 x 1 in elbows o 2 x ¾ in

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

430 Power/Electronics Replacement

430 Power/Electronics Replacement Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Installation Guide 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Table of Contents Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom Panel) 6 Specifications

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top. Here are some pictures to show what s required when replacing the A/C compressor, expansion valve and receiver/drier on a 2001 Volvo V70. Even if you don t replace these A/C parts these pictures can help

More information

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug Electrical Connection When installed the range must be electrically grounded in accordance with local codes or; in the absence of local codes with the National Electrical Code ANSI/NFPA 70, latest edition.

More information

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011 OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011 INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A

More information

Installation Instructions 6028.801

Installation Instructions 6028.801 DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American

More information

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00 Instructions for: TTW 1 Universal Service Kit P/N 265-47200-00 (To be performed ONLY by qualified service providers) The Blowers on the Following Water Heaters are Serviced by This Kit: MITW -10 Series

More information

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)

More information

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA CONTROL & OPERATING INSTRUCTIONS The controls on your new

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Installation Guide 2010 BMW S1000RR Full Exhaust System

Installation Guide 2010 BMW S1000RR Full Exhaust System Installation Guide 2010 BMW S1000RR Full Exhaust System!! THIS PRODUCT IS DESIGNED FOR USE IN CLOSED COURSE RACING AND IS NOT INTENDED FOR HIGHWAY USE!! Congratulations on the purchase of your new TaylorMade

More information

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions Overview Audience These installation instructions are intended for all cable system

More information

Ocean Engineering Technical Data Sheet Stuffing Tubes

Ocean Engineering Technical Data Sheet Stuffing Tubes Ocean Engineering Technical Data Sheet Stuffing Tubes Stuffing tubes are devices used to allow a wire or cable to pass through a wall or bulkhead and protect components from the outside environment. Many

More information

Solstice/Sky Water Pump Replacement

Solstice/Sky Water Pump Replacement Solstice/Sky Water Pump Replacement The water pump on the Solstice/Sky is starting to need replacement on some vehicles. This guide will help in replacing the water pump while the engine is still in the

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT -J00 REV. 00-- DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT GENERAL Kit Number -A, 0-, -, 0-, -, - 0, -0 Models These kits fit and later FXST, FXSTB, FXSTC, and and later FXDWG Harley-Davidson model

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Second Edition (June 2014) 2014 Contents Chapter 1. Safety information..... 1 Chapter 2. Rack kit parts inentory... 3 Chapter 3. Rack installation...... 5 Identifying the

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................

More information

42U/45U 28" Wide Rack Installation & Service Guide

42U/45U 28 Wide Rack Installation & Service Guide 42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part

More information

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS Tools required: 10mm/13mm socket and 3/8 drive ratchet with extension Torx T20/25/30 screwdrivers or bits Phillips head screwdriver,

More information

Anthro Tablet Charging Cabinets

Anthro Tablet Charging Cabinets Owner's Manual for Anthro Tablet Charging Cabinets Covers part numbers beginning TAB16 and TAB20. Components at a Glance The open views of the front and side of the cabinet below are for the TAB20 cabinet.

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

CutMaster 82. 6.04 Major External Replacement Parts

CutMaster 82. 6.04 Major External Replacement Parts CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080

More information

Installation Guide for Artic Air 24 Volt R134A Air Conditioner

Installation Guide for Artic Air 24 Volt R134A Air Conditioner Installation Guide for Artic Air 24 Volt R134A Air Conditioner Rev 004 April 20, 2014 There are five objectives to installing the Artic Air unit: 1) The primary wiring from the battery, 2) The controller

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

Traditional Sonar and DSI Sonar Installation

Traditional Sonar and DSI Sonar Installation Traditional Sonar and DSI Sonar Installation This document covers the installation of the transducer and display unit installation, which includes connecting the unit to power and installing the unit on

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

INSTALLATION INSTRUCTIONS FOR 2006-2009 VW MK5

INSTALLATION INSTRUCTIONS FOR 2006-2009 VW MK5 CI100018 INSTALLATION INSTRUCTIONS FOR 2006-2009 VW MK5 Rabbit, Jetta 2.5L These instructions are applicable to vehicles equipped with either manual or automatic transmissions Thank you for choosing to

More information

H41 Electrical Stage Aft Air Conditioner Unit Installation

H41 Electrical Stage Aft Air Conditioner Unit Installation Aft Air Conditioner Unit Installation 1. Place Air-Cond unit in A/C shelf with air return facing fwd direction of the boat. 2. Do not secure Air-Cond Unit on shelf, install both side of air condition ABS

More information

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly Replacing the Cover Micro-Switch To remove and replace the Cover Micro-Switch you will need the following tools: #2 Phillips screwdriver (magnetic tip preferred) #1 Phillips screwdriver (magnetic tip preferred)

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Before installation it is important to know what parts you have and what the capabilities of these parts are. INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With

More information

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 This instruction shows how to replace the OEM intercooler with our performance intercooler. 2. 3. 1. 4. 5. Part number: ICM-170 6. At

More information

CHEMICAL CLEANING UNIT Product number: 737189

CHEMICAL CLEANING UNIT Product number: 737189 CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2

More information

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED

More information

FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER

FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Please read before beginning Stainless steel hardware

More information

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS

More information

MAC FAUCETS. Owner s Manual. Models: FA444

MAC FAUCETS. Owner s Manual. Models: FA444 MAC FAUCETS Owner s Manual Models: FA444 Installation procedure: 1. Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation. Connect

More information

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054 owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION ENGLISH REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION INSTALLATION GUIDELINES For International Prostar ISO 9001:2000 L 2647 Rev. 20090130 WARNING: Only trained technicians should perform

More information

Hose and Tube Fittings Series 1-3

Hose and Tube Fittings Series 1-3 Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47) 47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

More information

2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure

2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure 2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure Derek Guenther 1/28/2015 Rev. Purpose The purpose of this document is to describe the procedure necessary to replace one of the ball nuts

More information

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT -J070 REV. 0-0-0 FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT GENERAL Kit Number 9-09A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com

More information

Post Mount Light Installation*

Post Mount Light Installation* Post Mount Light Installation* *For the general installation of most Post Mount Spotlights, many vehicles may need slight modifications to these instructions. You will need the following tools: High torque

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: SPK-C411 Closed-back Ceiling Speakers SPK-C412. P/N: 2900-300188 Rev 1

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: SPK-C411 Closed-back Ceiling Speakers SPK-C412. P/N: 2900-300188 Rev 1 KRAMER ELECTRONICS LTD. USER MANUAL MODELS: SPK-C411 Closed-back Ceiling Speakers SPK-C412 Closed-back Ceiling Speakers P/N: 2900-300188 Rev 1 This page is intentionally left blank Contents 1 Introduction

More information

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set

More information

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH HFC 134a Ozone Friendly Refrigerant FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH AAAMU-60 / INSIDE PASSENGER COMPARTMENT INSTALLATION MANUAL 2000 (EUROPE) B.V.. All Rights Reserved. This

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

Panel Track Installation Guide

Panel Track Installation Guide Panel Track Installation Guide We make it easy! BTG 493361 EN_0510 Before starting Your new Blinds To Go panel track is custom made to your specifications from the finest materials available. To ensure

More information

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Andersen Electric Window Opener for Andersen Awning and Roof Windows W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of

More information

5800 Temperature Sensor Cable Assembly

5800 Temperature Sensor Cable Assembly 5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the

More information

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS.  Construction Automotive Industry DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.

More information

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range. ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3085ST LRE3083ST LRE3083SB LRE3083SW LRE3021ST LDE3037ST

More information

Installation Instructions 4662.003

Installation Instructions 4662.003 Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46) 46 Brakes - Mechanical Components (Page GR-46) Front brakes Brake pads, removing and installing Brake pads, removing and installing FN 3 brake caliper, servicing FS III brake caliper, servicing Rear wheel

More information

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents -J0 REV. 00--0 POWER LOCK KIT GENERAL Kit Number -0, 0-0 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories section of www.harleydavidson.com (English

More information

DCF Optimized Rack System

DCF Optimized Rack System Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

Fiberstars Mini Lighted Laminar Flow Fountains

Fiberstars Mini Lighted Laminar Flow Fountains Fiberstars Mini Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Mini Lighted Laminar Flow Fountain. The

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Turbo Tube Slide INSTALLATION INSTRUCTIONS C A U T I O N Do not climb on the outside of the slide This slide is designed for home use only, not for Public Playgrounds PlayCore, Inc. 2004 Copyrighted Material.

More information

Installation Instructions

Installation Instructions Installation Instructions S50-310 (Semi-Circular) S50-311 (Circular) Accu-Zone Infrared Control Conversion Kit for Terrazzo & Stainless Steel Classic Washfountains (Non-sectional) Table of Contents Pre-Installation

More information