1 Hitachi Compute Rack 220H User s Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90CRH003-02
2 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi, Ltd. Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication. When new or revised information becomes available, this entire document will be updated and distributed to all registered users. Some of the features described in this document might not be currently available. Refer to the most recent product announcement for information about feature and product availability, or contact Hitachi Data Systems Corporation at Notice: Hitachi, Ltd., products and services can be ordered only under the terms and conditions of the applicable Hitachi Data Systems Corporation agreements. The use of Hitachi, Ltd., products is governed by the terms of your agreements with Hitachi Data Systems Corporation. Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd., in the United States and other countries. Archivas, Essential NAS Platform, HiCommand, Hi-Track, ShadowImage, Tagmaserve, Tagmasoft, Tagmasolve, Tagmastore, TrueCopy, Universal Star Network, and Universal Storage Platform are registered trademarks of Hitachi Data Systems Corporation. AIX, AS/400, DB2, Domino, DS6000, DS8000, Enterprise Storage Server, ESCON, FICON, FlashCopy, IBM, Lotus, MVS, OS/390, RS6000, S/390, System z9, System z10, Tivoli, VM/ESA, z/os, z9, z10, zseries, z/vm, and z/vse are registered trademarks or trademarks of International Business Machines Corporation. All other trademarks, service marks, and company names in this document or website are properties of their respective owners. Microsoft product screen shots are reprinted with permission from Microsoft Corporation. ii
3 Contents Preface... v Intended Audience... vi Product Version... vi Release Notes... vi Document Organization... vi Referenced Documents... vii Document Conventions... vii Convention for storage capacity values... viii Getting Help... ix Comments... ix Before operation Avoiding trouble Bundled Software Monitoring operating status Fault detection Operation monitoring System Unit Functions Disk arrays Redundancy Wake On LAN Memory RAS LAN extended functions Operational precautions Precautions on LAN controller Precautions on internal devices Maintenance and service parts Daily maintenance items Cleaning Service parts Contents iii
4 Consumables Troubleshooting Solving problems Corrective actions for error iv Contents
5 Preface This document describes monitoring, functions, precautions, maintenance and troubleshooting for the Compute Rack 220H (CR 220H). Please read this document carefully, and maintain a copy for reference. This preface includes the following information: Intended Audience Product Version Release Notes Document Organization Referenced Documents Document Conventions Convention for storage capacity values Getting Help Comments Notice: The use of Compute Rack and all other Hitachi Data Systems products is governed by the terms of your agreement(s) with Hitachi Data Systems. Preface v
6 Intended Audience This document is intended for personnel who are involved in planning, managing, and performing the tasks to prepare your site for Compute Rack installation. This document assumes the following: The reader has a background in hardware installation of computer systems. The reader is familiar with the location where the Compute Rack will be installed, including knowledge of physical characteristics, power systems and specifications, and environmental specifications. Product Version This document revision applies to Compute Rack 220H version 0021R Release Notes Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document. Document Organization The table below provides an overview of the contents and organization of this document. Click the chapter title in the left column to go to that chapter. The first page of each chapter provides links to the sections in that chapter. Chapter Chapter 1, Before operation Chapter 2, Monitoring operating status Chapter 3, System Unit Functions Chapter 4, Operational precautions Chapter 5, Maintenance and service parts Chapter 6, Troubleshooting Description Describes what you should understand before operation. Describes means for fault detection of the system unit and an operation monitoring method. Describes the functions of the system unit that are useful in operation. Describes operational precautions. Describes daily maintenance procedures, service parts and consumables. Describes troubleshooting of the system unit. vi Preface
7 Referenced Documents Compute Rack 220H (CR 220H) documents: Hitachi Compute Rack 220H Getting Started Guide, MK-90CRH001 Hitachi Compute Rack 220H CRU Replacement Guide, MK-90CRH005 Hitachi Compute Rack 210H/220H Windows Installation Guide, MK-90CRH007 Hitachi Compute Rack 210H/220H BIOS Guide, MK-90CRH008 Hitachi Compute Rack 210H/220H Remote Management User's Guide, MK-90CRH006 Hitachi Compute Blade Series / Hitachi Compute Rack Series OS Installation Guide for Windows Server, MK-99COM076 Document Conventions The term Compute Rack refers to all Compute Rack models, unless otherwise noted. This document uses the following typographic conventions: Convention Regular text bold Italic Screen text Description In text: keyboard key, parameter name, property name, hardware labels, hardware button, hardware switch. In a procedure: user interface item Variable, emphasis, reference to document title, called-out term Command name and option, drive name, file name, folder name, directory name, code, file content, system and application output, user input < > (angled brackets) Variable (used when italic is not enough to identify variable). [ ] (square bracket) Optional values { } braces Required or expected value vertical bar Choice between two or more options or arguments _(underline) Default value, for example, [a b] Preface vii
8 This document uses the following symbols to emphasize certain information. Symbol Label Description WARNING This indicates the presence of a potential risk that might cause death or severe injury. CAUTION This indicates the presence of a potential risk that might cause relatively mild or moderate injury. NOTICE NOTICE This indicates the presence of a potential risk that might cause severe damage to the equipment and/or damage to surrounding properties. Note This indicates notes not directly related to injury or severe damage to equipment. Tip This indicates advice on how to make the best use of the equipment. Convention for storage capacity values Physical storage capacity values (for example, disk drive capacity) are calculated based on the following values: Physical capacity unit Value 1 kilobyte (KB) 1,000 (10 3 ) bytes 1 megabyte (MB) 1,000 KB or 1,000 2 bytes 1 gigabyte (GB) 1,000 MB or 1,000 3 bytes 1 terabyte (TB) 1,000 GB or 1,000 4 bytes 1 petabyte (PB) 1,000 TB or 1,000 5 bytes 1 exabyte (EB) 1,000 PB or 1,000 6 bytes Logical storage capacity values (for example, logical device capacity) are calculated based on the following values: Logical capacity unit Value 1 block 512 bytes 1 KB 1,024 (2 10 ) bytes 1 MB 1,024 KB or 1,024 2 bytes 1 GB 1,024 MB or 1,024 3 bytes 1 TB 1,024 GB or 1,024 4 bytes 1 PB 1,024 TB or 1,024 5 bytes 1 EB 1,024 PB or 1,024 6 bytes viii Preface
9 Getting Help Comments The Hitachi Data Systems customer support staff is available 24 hours a day, seven days a week. If you need technical support, log on to the Hitachi Data Systems Portal for contact information: Please send us your comments on this document: [email protected]. Include the document title and number including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems Corporation. Thank you! Preface ix
10 x Preface
11 1 Before operation This chapter describes what you should understand before operation. Avoiding trouble Bundled Software Before operation 1-1
12 Avoiding trouble This section describes the requirements for daily maintenance in order to avoid trouble that might occur during system unit operation. System error check If some error occurs with the system unit, an error message might be displayed. To resolve trouble early, verify such alerts immediately. Hardware errors Perform error monitoring based on the ERROR LED of the system unit. See Fault detection on page 2-2 and Operation monitoring on page 2-7 Software errors Consistency check Periodically monitor a software error event log. A software error, if one occurs, is recorded on the event log. For verification of the event log of software attached to the system unit, see the individual software manuals. See Bundled software on page 1-5 In a disk array, a re-assign (data migration to a reserved area) is performed if a bad block (inaccessible area) is detected on the HDD/SSD during the read/write process. However, if a bad block exists in the mirror data part as well as in the area not accessed for daily operations, no alternation process is performed. If the HDD/SSD fails in such a state, data in the bad block cannot be rebuilt normally and thus might be lost because mirror data cannot be read. The disk array of the system unit is equipped with a patrol read function that has been set to the factory default so it can verify or fix the HDDs/SSDs periodically. Therefore, there is no need to conduct a consistency check periodically. 1-2 Before operation
13 Network Security Recent years have seen an increase in attacks on systems by computer viruses and in data falsification or leaks by hacking, resulting in more serious damage. Infection by computer viruses not only affects your own system unit (victim) but also might inflict damage on the unspecified number of targets through networks (victimizer). In most cases, it is often said that inflection is caused by careless downloading of data or use of data media of unknown origin. Effective means to prevent infection include installation of anti-virus software or firewall for blocking illegal access. We recommend introducing preventive means simultaneously whenever a network connection is established. Also, security can be maintained by keeping the anti-virus software up-to-date. However, this does not mean that the anti-virus software can always prevent infection with computer viruses. It becomes important to establish and operate a system to prevent infection with such viruses. System scan Some computer viruses send their own copies one after another to a connected network. If your computer is infected, we recommend disconnecting your LAN cable immediately and isolating the computer from the network in order to prevent secondary infection. Periodically check if computer viruses are hidden. It is convenient to use anti-virus software s scheduling function that enables automatic scanning periodically. Downloading the latest date It is essential to always update anti-virus software in order to address computer viruses that evolve on a daily basis. A virus pattern file and the version of anti-virus software are included as the data to be updated. No computer viruses can be found or eliminated if neither the pattern file nor the software version responds to the virus invaded. We recommend establishing an environment where your anti-virus software can be updated automatically and periodically. See the manual that comes with your anti-virus software for more details on how to use the anti-virus software. Windows update check If Microsoft Windows operating system (OS) is in use, Microsoft Corporation has released an additional program to fix errors or vulnerability of its Windows OS. Please visit the Windows Update website to confirm and install update programs periodically. Windows Update Website: Windows Update is also accessible from your Windows start menu. Before operation 1-3
14 Storing backup data For storage devices such as HDD and SSD, or data media such as USB and memory, an incorrect operation such as a failure or wrong formatting might lose important data unexpectedly. If system data (data contained in Windows folders) are destroyed, it becomes necessary to reinstall or set up the OS or applications and thus it will take a long time to recover the system. To take proper measures, backup data can be stored on tape or similar media to restore the system to its most previous working state if data loss occurs. It is also possible to restore the system to normal by creating system information backup data if system data become lost or corrupted. We recommend backing up the system data periodically. For details on how to create and restore backup data, see the Windows Help or visit the Microsoft website and search the page of backup technical information. If backup software is used, see the manual that comes with the software. Microsoft Website: Operational trouble In case of trouble or unfamiliar matters of operation, see Solving problems on page Before operation
15 Bundled Software Install and use the following software program bundled with the system unit. MegaRAID Storage Manager This utility is necessary to manage disk array devices. If this utility is not installed, no HDD failure can be detected, which will cause a double failure and loss of data. For details about using this utility, see MegaRAID Storage Manage Instruction Manual. Hardware Maintenance Agent The Hardware Maintenance Agent is a utility necessary for maintenance of the system unit. If a failure occurs on the system unit, this utility analyzes such a failure automatically, thus facilitating identification of this failure and shortening system recovery time. For details about using this utility, see Hardware Maintenance Agent Windows Edition User s Guide. Before operation 1-5
16 1-6 Before operation
17 2 Monitoring operating status This chapter describes system unit fault detection and methods monitoring operation. Fault detection Operation monitoring Monitoring operating status 2-1
18 Fault detection This section describes how to detect a fault on the system unit. The system unit notifies fault occurrence by the following: Table 2-1: Fault detection method No Method Description Remarks 1 ERROR LED Turns on in case of a system unit hardware error. The LED turns off after error recovery. 2 MAINTENANCE LED Indicates a POST code, an event code, and a power consumption value alternately. Each code can be retained and displayed even in the standby state (with AC cord connected and POWER switch OFF). The previous code is cleared when the power is turned on (POWER switch is turned on). 3 OS event log 4 STOP message Records an event as a system log, a security log or an application log. Stores an event log generated at a system level or an application leveling the following directory, as well as an error message: %SystemRoot%\SYSTEM32\config Indicates if an error occurs in the kernel due to a configuration definition mismatch between hardware and software, a hardware failure, or a software glitch (OS and drivers). The logs can be referenced by using an event viewer. - 5 Error notification by utility Gives a message notification on an error detected by utility software or drivers. RAID management utility (MegaRAID Storage Manager) and so on MAINTENANCE LED ERROR LED Figure 2-1: ERROR LED and MAINTENANCE LED 2-2 Monitoring operating status
19 ERROR LED The Baseboard Management Controller (BMC), an onboard management controller of the system unit, turns on the ERROR LED on the front of the system unit if a hardware error occurs, such as a HDD error, a fan error, a power supply error, and others. The sensors having a threshold are lit up in the Critical State (a critical state of the system unit). But do not turn on in the Uncritical State (a state in which a component has a failure under redundancy). MAINTENANCE LEDs Dot LEDs Figure 2-2: MAINTENANCE LEDs MAINTENANCE LEDs can display the event code, the POST code or the power consumption, and you can select what to display on it by using the SERVICE switch. A combination of ON/OFF selections of Dot LED (left), Dot LED (right), and SERVICE LED determines what is currently displayed. A combination of ON/OFF selections of Dot LED (left), Dot LED (right), and the SERVICE LED determines what the MAINTENANCE LEDs indicate as follows: Table 2-2: What the MAINTENANCE LEDs indicate SERVICE LED Dot LED (left) Dot LED (right) What the MAINTENANCE LEDs indicate Off Off Off Event code On On Off POST code Off On On Power consumption Monitoring operating status 2-3
20 Every time you press the SERVICE switch, the MAINTENANCE LEDs will change the code to display as follows. Pressing of SERVICE switch (number: press count) Figure 2-3: MAINTENANCE LEDs indicate pressing of SERVICE switch Event code The operation status of the system unit is displayed. Under normal operation, "00" is displayed. If an error occurs, the two-digit number corresponding to the component where the error occurred is indicated at LED. Table 2-3: Event code indicate MAINTENANCE LED Where the error occurred MAINTENANCE LED Where the error occurred 00 Normal operation 10 PCI 01 Other hardware 20 Motherboard 02 Temperature 40 Memory 04 Fans 80 CPUs 08 Power / Voltage (Other codes) (Multiple locations) POST code The POST code of the system BIOS is displayed. If Power On Self Test (POST) is successful, "A.E" is displayed. The MAINTENANCE LEDs keep the data of the POST code and the event code unless the AC power source is turned off. When the power of the system unit is turned on, the display gets cleared. 2-4 Monitoring operating status
21 Power consumption The rough estimate of the current power consumption of the system unit (W) is displayed. The upper digit (left side) indicates the 100's digit, and the lower digit (right side) indicates the 10's digit. The indicated power consumption value is not accurate. Use this value as a just reference. OS event log An event log is the data required for investigation in Windows OS. Events that have occurred inside the OS are recorded in the event log in chronological order. The "Event Viewer" is provided as a management tool for referencing the event log. In the Windows Start menu, click Start > Administrative Tools > Event Viewer. For details, see the Event Viewer's help. Event types include information, warnings and errors. It has been confirmed that events are temporary or known instances even if they are errors or warnings. In case of an error or a warning, see Hitachi Compute Rack 210H/220H Windows Installation Guide or the manual that comes with the software being used. For general Windows instances, verify the support technical information (Knowledge Base) of Microsoft Corporation. Microsoft Support Online: Monitoring operating status 2-5
22 STOP message and memory dump If the Windows OS has been trapped in a critical state for some reason, a blue screen appears and a STOP message is displayed. At this time, Windows can save the STOP message information in a dump file. This is referred to as a memory dump. If Windows is hung up, the cause of a failure can be narrowed down by analyzing the memory dump. The following three types of memory dumps are available: Minimum memory dump (64 KB) Kernel memory dump Full memory dump The full memory dump is effective in fault investigation. The other dumps are extremely difficult to analyze because of less information contained therein. The following conditions are required for full memory dump. When you configure partitions, be aware of acquisition of a full memory dump during system construction. A page file is in the Windows-installed drive (C drive). A page file is larger than physical memory installed MB. Free space for a dump file should exist in the C drive. For details on the setting of a page file (virtual memory), see Windows help. Error notification by utilities Utility programs, such as MegaRAID Storage Manager, use a popup message or an internal event log to be displayed for error notification. For more details on error notification of those utilities, see the individual manuals. 2-6 Monitoring operating status
23 Operation monitoring This section describes the items to be monitored on a daily basis on the system unit. As mentioned in Fault detection on page 2-2, the system unit has a variety of functions for giving hardware or software error notifications. Using these functions, monitor the operation so as not to overlook a fault or its symptom. Major monitoring items are as follows: Table 2-5: Major monitoring items No Item Checking cycle 1 Check the operating status of the system unit or internal options for errors, such as turned on ERROR LED and fans abnormal noise. Every six months 2 Check an OS event log for errors. Every day 3 Check for error notifications by utilities. Every day To monitor the operation of the system unit, see the following manuals: Operating status of system unit and internal options See Maintenance and service parts See Optional PCI card instruction manual Monitoring of OS event logs Manuals that come with the OS Help of OS monitoring tools Monitoring by RAID management utility "MegaRAID Storage Manager" See MegaRAID Storage Manager Instruction Manual Monitoring by other utilities Manual that comes with each utility Monitoring operating status 2-7
24 2-8 Monitoring operating status
25 3 System Unit Functions This chapter describes the functions of the system unit that are useful in operation. Disk arrays Redundancy Wake On LAN Memory RAS LAN extended functions System Unit Functions 3-1
26 Disk arrays This section describes the disk array functions. About disk arrays The disk array is a technique used as one or more logical units (LU) by connecting two or more physical drives (HDD or SSD) to each other, which is also referred to as a Redundant Arrays of Inexpensive Disks (RAID). The disk array has two main advantages: one is to segment data into some component and decentralize onto the HDDs/SSDs in the disk array (data striping) in order to improve I/O performance higher than a single drive in terms of a disk array, and the other is to create an array parity for data recovery in order to prevent data loss in case one of the HDDs/SSDs in the disk array should fail. NOTICE Even the disk array cannot prevent data loss that is caused by a non-hdd/ssd failure, software overrun or operation errors. Just in case, back up your system data. Disk array: A virtual drive consisting of multiple physical drives, which cannot be recognized by the OS as it is. Logical drive: A logical drive configured in the disk array, which is recognized by the OS in the same manner as a physical drive. You can assign capacity larger than 2 TB (2199 GB) for the logical drive set as disk array but do not assign capacity larger than 2 TB for the logical drive the OS is installed to. Otherwise the OS cannot create a partition anymore. Use the RAID management utility or the RAID BIOS to reconstruct the disk arrays and the logical drives. 3-2 System Unit Functions
27 RAID level feature RAID0 Depending on a RAID level, disk arrays are typically classified into six types: RAID0 to RAID5. The system unit supports RAID0, RAID1, and RAID5 as well as RAID6, RAID10, JBOD which are specific to the array controller. The method and features of each RAID level are described below. Figure 3-1: RAID0 method Data is striped on multiple HDDs/SSDs. Advantage: Particularly, the throughput is improved for a large number of files. Disadvantage: All data is lost if one of the HDDs/SSDs in the disk array fails because of no redundancy. Number of HDDs/SSDs required: 2 (min.) to 8 (max.) System Unit Functions 3-3
28 RAID1 Figure 3-2: RAID1 method Data is stored on one HDD/SSD (data drive) and the other one (mirrored drive). Advantage: Provides 100% data redundancy, thus enabling easy switching between two drives to continue read or write processing if a drive failure occurs. HDD/SSD interchange also allows data reconstruction without shutdown operations. Disadvantage: A double HDD/SSD capacity is required because a mirrored disk of the same capacity should be installed. An attempt to read or write data during data rebuild causes a decrease in processing performance. Number of HDDs/SSDs required: System Unit Functions
29 RAID5 Figure 3-3: RAID5 method Data is striped block by block on all the HDDs/SSDs together with array parity. Advantage: As compared to RAID1, the capacity cost effectiveness is improved. Data distribution onto HDDs/SSDs provides data redundancy. Therefore, a read or write can be performed on each HDD/SSD independently. Data striping on a block basis is suitable for transaction processing. Even if one of the HDDs/SSDs in the disk array fails, read or write processing can be continued while array parity is computing the lost data. HDD/SSD interchange enables data reconstruction without shutting down operations. The array parity distributed on each HDD/SSD has the advantage that parallel processing by independent access to HDDs/SSDs is implemented during data write operation. Disadvantage: RAID5 is inferior to RAID0 in write performance because of an array parity generated during write processing. An attempt to read or write data during data rebuild causes a decrease in processing performance. Number of HDDs/SSDs required: 3 (min.) to 8 (max.) System Unit Functions 3-5
30 RAID6 Figure 3-4: RAID6 method Data is striped block by block on all the HDDs/SSDs together with array parity. Advantage: As compared to RAID5, two types of parities generated improve redundancy. Data distribution onto HDDs/SSDs provides data redundancy. Therefore, a read or write can be performed on each HDD/SSD independently. Data striping on a block basis is suitable for transaction processing. Even if up to two of the HDDs/SSDs in the disk array fail, read or write processing can be continued while array parity is computing the lost data. HDD/SSD interchange enables data reconstruction without shutting down operations. The array parity distributed on each HDD/SSD has the advantage that parallel processing by independent access to HDDs/SSDs is implemented during data write operation. Disadvantage: RAID6 is inferior to RAID5 in write performance because of two types of parities generated during write processing. An attempt to read or write data during data rebuild causes a decrease in processing performance. Number of HDDs/SSDs required: 4 (min.) to 8 (max.) 3-6 System Unit Functions
31 RAID10 Figure 3-5: RAID10 method Data is striped on multiple HDDs/SSDs and is duplicated. The features of both RAID0 and RAID1 are provided. Advantage: Provides 100% data redundancy, thus enabling easy switching between two drives to continue read or write processing if a drive failure occurs. HDD/SSD interchange also allows data reconstruction without shutdown operations. Particularly, the throughput is improved for a large number of files. Typically, RAID10 is superior to RAID5 in write performance because no array parity is generated. Disadvantage: A double HDD/SSD capacity is required because a mirrored disk of the same capacity should be installed. An attempt to read or write data during data rebuilding causes a decrease in processing performance. Number of HDDs/SSDs required: Even number from 4 (min.) to 8 (max.) System Unit Functions 3-7
32 JBOD Figure 3-6: JBOD method Data is stored only on one HDD/SSD. JBOD performs no data redundancy and works like a HDD/SSD connected to a typical SAS/SATA controller. Number of HDDs/SSDs required: 1 JBOD is RAID0 configured with one HDD/SSD. 3-8 System Unit Functions
33 Functions of Disk Array Degraded mode NOTICE If another HDD/SSD failure occurs while the disk array is operating in degraded mode, the disk array cannot rebuild data, thus losing all data. Replace the failed drive as soon as possible and rebuild data. Even if one of the HDDs/SSDs in RAID1, RAID5, RAID6, or RAID10 disk array fails*, you can continue to use the disk array as usual. It is said that the disk array with one HDD/SSD failing* is operating in degraded mode. In response to a read/write request, the array controller uses the data and array parity (for RAID5 and RAID6) of the active drives to compute the data of the failed drive and continue operation as it is. However, the data computation required causes a decrease in processing performance as compared to the normal status. *: RAID6 can operate even if two HDDs/SSDs fail. If a HDD/SSD fails in the drive group having multiple logical drives, all the drives under the drive group will operate in degraded mode. Rebuilding data In the disk array of RAID1, 5, 6, or 10, after the failed drive is replaced, the array controller restores and stores data on the replaced drive. This is referred to as rebuilding data. Although the disk array can continue operating while rebuilding data, its processing performance lowers kind of degraded mode as compared to normal status. If another HDD/SSD failure occurs while the disk array is operating in degraded mode, the disk array cannot rebuild data, thus losing all data. In such a case, replace the failed drive as soon as possible and rebuild data. RAID0 and JBOD cannot rebuild data because neither data duplication nor parity generation is conducted on their drives. System Unit Functions 3-9
34 Hot plug If a logical drive is operating in degraded mode, the failed drive must be replaced as soon as possible. If the system unit is shut down once at this time, it takes more time to replace the drive. Above all, the system operation must be shut down. It will take longer time to replace the degraded drive after turning off power to the system unit. A hot plug or hot swap is referred to as a function for resolving this problem, enabling the user to replace a HDD/SSD without shutting down the system unit. Hot spare If a failure occurs on the logical drive of RAID1, 5, 6, or 10, the failed drive must be replaced to return the system normal status. If a spare drive (reserve drive) is premounted on the array controller, data can be automatically restored on the reserve drive in case of a failure. Preparing this reserve drive so that it can be exchanged at any time is referred to as a hot spare. A function for the array controller to restore data automatically to the hot spare is referred to as standby replacement. Depending on a logical drive configuration, a hot spare might be unavailable. Hot spares include a "global hot spare" that becomes effective to all the configured logical drives (RAID1, 5, 6, and 10), and a "dedicated hot spare" that becomes effective only to one of the configured logical drives (RAID1, 5, 6, or 10) System Unit Functions
35 SMART copyback function SMART copyback is a function to replace an HDD/SSD safely. If a SMART failure occurs on an HDD/SSD in the logical drive of RAID1, 5, 6, or 10, a data of the failed HDD/SSD is copied to a reserve drive with keeping redundancy of a logical drive. This function decreases the outbreak probability of the failure of a logical drive according to the failure of a further HDD/SSD under rebuilding. However, the process performance decreases in comparison with normal state under copying to perform data copying by SMART copyback. Figure 3-7: SMART copyback function System Unit Functions 3-11
36 Failure recovery flow The failure recovery flow for RAID5 with five physical drives working is illustrated below. In this illustration, two cases are explained: one with a reserve drive and the other without a reserve drive. Figure 3-8: A case with a reserve drive 3-12 System Unit Functions
37 Figure 3-9: A case without a reserve drive System Unit Functions 3-13
38 Precautions on building a disk array HDDs/SSDs The HDD/SSD used with one disk array must have the same capacity and rotating speed. If two or more disk arrays are built on the system unit, HDDs/SSDs used with each disk array might be different. If a reserve drive is used, however, care must be taken for operation. For details, see Reserve drive on page Disk array A: HDD/SSD A-0 = A-1 = A-2 Disk array B: HDD/SSD B-0 = B-1 = B-2 However, there is no problem if A-x B-x Figure 3-10: Capacity of the HDD/SSD to use for disk array HDD/SSD installation location In consideration of system management, install in a successive extension storage bay the HDDs/SSDs to be used with a single disk array. We also recommend to record disk array and logical drive configurations. If a failure occurs, however, the installation location depends on whether a reserve drive is provided. For this reason, make a record each time. Disk array A: Extension storage bays 1 and 2 Disk array B : Extension storage bays 3 to 6 Disk array A: Extension storage bays 2 and 5 Disk array B: Extension storage bays 1, 3, 4, and 6 Figure 3-11: HDD/SSD installation location 3-14 System Unit Functions
39 Reserve drive Install a reserve drive same as drive type, capacity and rotation speed. If set for "global hot spare", install largest-capacity HDD/SSD. Note that if there are two or more disk arrays, an attempt to set a reserve drive as a "global hot spare" will cause the following event. Be extremely careful with the operation. A reserve drive example is described below by using the following disk array. Disk array A: RAID1 Disk array B: RAID5 Reserve drive: Provided Figure 3-12: Example for install reserve drive For the disk array configured with HDDs, install HDD as reserve drive, for the disk array configured with SSDs, install SSD as reserve drive. Other type of disk array cannot be configured as reserve drive. System Unit Functions 3-15
40 Two or more disk arrays with a RAID level of 1, 5, 6, or 10 The reserve drive functions as a hot spare on either disk array. Depending on an HDD/SSD hot spare, the following configuration is applied. A A failure occurs on HDD/SSD A-1 of disk array A. B A failure occurs on HDD/SSD B-1 of disk array B. C A failure occurs on HDDSSD A-1 of disk array A. Figure 3-13: Transition of reserve drive As the result of standby replacement, the drive A1 and B1 location move to another drive. In other words, the HDDs/SSDs constituting a disk array might be positionally interchanged. Therefore, in consideration of system management, record the locations of HDDs/SSDs each time in case of a failure System Unit Functions
41 A difference in capacity between the HDDs/SSDs used in disk arrays A and B Depending on the capacity of a reserve drive, a hot spare might not work. The following hot spare will be applied depending on the capacity of a reserve drive. This description assumes disk array A < disk array B (A - x < B - x). If the reserve drive has the same capacity as B-x: The reserve drive works as a hot spare either in disk array A or B. If the hot spare is used in disk array A (A and C are applied to the case where Two or more disk arrays with a RAID level of 1, 5, 6, or 10), an unused area will exist on the rebuilt HDD/SDD because the reserve drive is greater in capacity than HDD/SDD A-x used in disk array A. If the reserve drive has the same capacity as A-x: The reserve drive works as a hot spare only in disk array A, not in disk array B. No data can be restored on the HDD/SSD because the reserve drive is smaller in capacity than the HDD/SSD B-x used in disk array B. Therefore, disk array B remains in degraded mode. To prevent the above, fit the capacity of a reserve drive to the disk array or prepare a reserve drive for each disk array. The priority of a reserve drive used in case of a failure is as follows: 1 A reserve drive having the same capacity as a failed drive 2 A reserve drive with a small device ID, in order of a storage bay number. System Unit Functions 3-17
42 Redundancy Power supply This section describes the redundant components of the system unit. Installation of two power supplies on the system unit enables power supply duplication. This allows continuous operation without shutting down the system unit if either of the power supplies fails. Each power supply supports a hot plug. Therefore, a failed power supply can be replaced without shutting down the system unit. We recommend connecting two power supplies to different power sources, respectively, if installed. In case of a failure on one power source, the system unit can operate without a shutdown, as long as power is still supplied from the other source. If a failure occurs in one power supply, contact the sales representative or maintenance personnel. Replace the failed power supply as soon as possible. System fans The system unit has system fans for internal cooling. Some of these fans are designed to be redundant. The system unit can operate without a shutdown even if one of the system fans fails. If a system fan failure occurs, contact the sales representative or maintenance personnel. Replace the failed system fan as soon as possible System Unit Functions
43 Wake On LAN This section describes the Wake On LAN feature. Overview of the remote power-on The Wake On LAN function is a function to turn on the power to system unit through a network. The system unit, if turned off, can be turned through a remote operation by transmitting special packets from the system unit for the administrator or from a client. You can use a remote power-on operation by using the onboard remote management function only on the Web console. Support conditions for the Wake On LAN The Wake On LAN function is supported under the following conditions. Supported OS: Windows Server 2008 R2 Supported LAN devices: Onboard LAN controller 1 Only network interface connector 1 on the rear of the system unit is available. Network interface connector 1 Figure 3-14: Network interface connector 1 Network interface connector 2, management interface connector, optional LAN mezzanine and LAN card are not supported. Onboard LAN controllers (network interfaces) are displayed on the device manager, as follows: Onboard LAN1: PCI bus 8, device 0, function 0 Onboard LAN2: PCI bus 8, device 0, function 1 System Unit Functions 3-19
44 Precautions on use of the Wake On LAN In the following cases, the Wake On LAN function does not work. Press the POWER switch of the system unit once to activate the OS. Then, turn off the power in a normal procedure: When you start the system first after connecting the power cable. When the previous system end procedure was not normal If the POWER switch is pressed to turn off the power before the OS is activated (during BIOS POST) If the power is turned off using the UPS management software, If the power is not supplied to the system unit, such as the AC cable is disconnected or the circuit breaker is tripped, or in case of a power failure. If the system is shut down when connected to link partner, the Wake On LAN-enabled onboard LAN controller 1 is automatically set to 10 Mbps of link rate. After the OS is activated, the link rate returns normally. The system unit does not support Wake On LAN, from the sleep state, hybrid sleep state, and hibernation state System Unit Functions
45 Memory RAS This section describes the memory RAS feature supported by the system unit. Online spare memory Online spare memory is a function that can be switched online to spare memory if a correctable memory error (Correctable Error: 1-bit error) occurs frequently. This provides preventive maintenance of memory switching before an uncorrectable memory error (Uncorrectable Error: 2-bit error) occurs. These are the following conditions for using the online spare memory function: Two or more memory boards should be installed per channel. 8 or 12 memory boards (for 4 channels) per processor. All memory boards should have the same capacity and same model. When two processors are installed, the same memory configuration should be applied to processor 1 and processor 2. Figure 3-15: The number of the ranks of the memory board System Unit Functions 3-21
46 Online spare memory is set for each channel. One rank of the memory board installed on each channel becomes spare memory, and the other memory board rank becomes system memory. A "rank" represents a memory board configuration. Memory boards include a "single rank" and a "dual rank". Each memory board operates on a "rank" basis. Therefore, the "dual rank" is physically a single board but logically operates as two memory boards. The number of the ranks of the memory board which a system unit supports is as follows. Table 3-1: The number of the ranks of the memory board Product code Memory capacity Number of rank MJ702GL3-Y / MJ702GL3-R MJ7002H4-Y / MJ7002H4-R MJ704GL3-Y / MJ704GL3-R MJ7004H4-Y / MJ7004H4-R MJ708GL3-Y / MJ708GL3-R MJ7008H4-Y / MJ7008H4-R MJ716GL3-Y / MJ716GL3-R MJ7016H4-Y / MJ7016H4-R 2048 MB MB MB MB 2 In the case of a memory error, memory switching is performed on a rank basis. For instance, on the assumption that a memory board having two rank is installed on memory slots 1 and 5 (channel 1) of processor 1, and a memory board of rank 0 in memory slot 1 is set as a spare memory. If a correctable error occurs frequently on memory board of rank 0 in memory slot 5, all data in the memory is copied online to memory board of rank 0 in memory slot 1 which is spare memory. After the completion of copying, the system unit starts operating by using the memory boards not including the memory board of rank 0 in memory slot 5. Figure 3-16: Operation of the online spare memory function 3-22 System Unit Functions
47 In the case of a memory board having one rank, one memory board becomes spare memory. The online spare memory function becomes valid again when you restart the system unit. At this time, the spare memory is set again. Therefore, replace the failed memory board before restarting the system unit. The precautions on the use of online spare memory are as follows: The spare memory is set to every channel of each processor. To validate the online spare memory function, set Chipset > North Bridge > Memory Mode to Sparing on the system BIOS setup menu. The online spare memory functions in the channel of each processor once. The online spare memory function does not work then to become invalid even if a memory fault occurs with other channels of the processor. When the online spare memory function is set valid, one rank of a memory board to be installed on each channel is used as a spare memory. Therefore, the memory capacity is displayed smaller than the actual one. On the system BIOS setup menu, confirm Chipset > North Bridge > Total Memory. Depending on a memory board installed, the spare memory capacity per channel is as follows: Table 3-2: Spare memory capacity Installed memory boards MJ702GL3-Y / MJ702GL3-R MJ7002H4-Y / MJ7002H4-R MJ704GL3-Y / MJ704GL3-R MJ7004H4-Y / MJ7004H4-R MJ708GL3-Y / MJ708GL3-R MJ7008H4-Y / MJ7008H4-R MJ716GL3-Y / MJ716GL3-R MJ7016H4-Y / MJ7016H4-R Spare memory capacity per channel 2048 MB 4096 MB 4096 MB 8192 MB If memory degradation occurs, the online spare memory function becomes invalid. The OS might operate slowly within a range of a few seconds to ten minutes while the online spare memory function is working to change over to spare memory. In case of an uncorrectable memory error (Memory Uncorrectable Error: 2-bit error and so on), the online spare memory function does not work. When the online spare memory function works to change over to spare memory, the event cord by the MAINTENANCE LED in front of the system unit indicates as "40". See MAINTENANCE LEDs on page 2-3 You cannot use the online spare memory function simultaneously with memory mirroring, lock step, and device tagging. System Unit Functions 3-23
48 Memory mirroring Memory mirroring is memory duplication to continue to operate the system unit without a shutdown in case of an uncorrectable memory error (Uncorrectable Error: 2-bit error and so on). These are the following conditions for using the memory mirroring function: Memory boards should be installed in the same configuration for channels 0 and 1 as well as channels 2 and 3 of each processor. All memory boards should have the same capacity and same model. When two processors are installed, the same memory configuration should be applied to processor 1 and processor 2. Memory mirroring divides memory boards into a primary mirror depending on channels installed, and configures two channels in pairs. The relationship among memory slots, channels, and channel pairs is as follows. Figure 3-17: The memory pair of memory mirroring 3-24 System Unit Functions
49 In memory mirroring, a memory read and write are performed as follows: A read is performed from either the primary slot or mirror slot. A write is performed to both primary and mirror slots in appearance order. If an uncorrectable memory error occurs on one of the memory boards in the primary slot, all read and write operations are performed only on the memory boards in the mirror slot. If an error occurs on one of the memory boards in the mirror slot, contrarily, all read and write operations are performed only on the memory boards in the primary slot. The precautions on use of memory mirroring are as follows: To validate the memory mirroring function, set Chipset > North Bridge > Memory Mode to Mirroring on the system BIOS setup menu. When the memory mirroring function is set valid, the half of the memory boards installed are used as a mirror and thus the actual memory capacity used becomes half. On the system BIOS setup menu, confirm Chipset > North Bridge > Total Memory. The mirror memory slot is displayed as "0 MB" even if memory boards are installed. If memory degradation occurs, the memory mirroring function becomes invalid. In this case, the event cord by the MAINTENANCE LED in front of the system unit indicates as "40". See MAINTENANCE LEDs on page 2-3 You cannot use the memory mirroring function simultaneously with online spare memory, lock step, and device tagging. System Unit Functions 3-25
50 Lock step A memory lock step is a function for synchronizing two channels with each other and handling two memory boards as a single memory board logically. Normal access of 64-bit data/8-bit ECC is expanded to 128-bit data/16-bit ECC for operation. This allows enhancement of multi-bit error detection and correcting functions by Single Device Data Correction (SDDC). Typically, the memory controller supports x4 SDDC (able to correct a 4-bit DRAM device failure) and also using the lock step function allows support of x8 SDDC (able to correct an 8-bit DRAM device failure) as well as detection of two 4-bit DRAM device failures. These are the following conditions for using the lock step function: Memory boards should be installed in the same configuration for channels 0 and 1 as well as channels 2 and 3 of each processor. All memory boards should have the same capacity and same model. When two processors are installed, the same memory configuration should be applied to processor 1 and processor 2. SDDC is also referred to as advanced ECC, which assigns the data of each DRAM chip to individual ECC controllers so that a single DRAM chip does not affect one or more bits of data to be processed on an ECC basis. If the entire one DRAM chip fails, an error occurs on multiple bits. Each ECC controller can handle such an error as a 1-bit error for error correction. The x4 SDDC functions image is as follows. Figure 3-18: The function of x4 SDDC 3-26 System Unit Functions
51 The precautions on use of lock step are as follows: To validate the lock step function, set Chipset > North Bridge > Memory Mode to Lock Step on the system BIOS setup menu. Interleave between channels is not performed, so the memory access performance becomes lower than independent mode. In case of a correctable memory error, such as a 1-bit error or single DRAM chip error, automatic correction is continued. At this time, the ERROR LED does not turned on. If an uncorrectable memory error occurs, ECC-based error correction becomes unavailable and thus the system is shut down. You cannot use the lock step function simultaneously with online spare memory, memory mirroring, and device tagging. Device tagging Memory device tagging is a function for providing redundancy on a DRAM chip basis so that the system can operate without a shutdown even if one DRAM chip on a memory board breaks down. Normally, memory generates an ECC from data and stores on each DRAM chip separately from data. If the entire single DRAM chip fails, the data stored on the failed DRAM chip is calculated according to the data and ECC stored on other DRAM chips in order to rewrite the data on the DRAM chip storing ECC. This can avoid an uncorrectable memory error caused by a multi-bit error. Figure 3-19: The function of device tagging System Unit Functions 3-27
52 The precautions on use of device tagging are as follows: To validate the device tagging function, set Chipset > North Bridge > Device Tagging to Enabled on the system BIOS setup menu. The device tagging operates in independent mode to interleave between channels. In case of a correctable memory error, such as a 1-bit error or single DRAM chip error, automatic correction is continued. At this time, the ERROR LED does not turned on. For the device tagging function, only one memory board is used for operation per channel. If DRAM chips on multiple memory boards in one channel fail, the device tagging function does not work and the system is shut down. If an uncorrectable memory error occurs, ECC-based error correction becomes unavailable and thus the system is shut down. You cannot use the device tagging function simultaneously with online spare memory, memory mirroring, and lock step System Unit Functions
53 LAN extended functions This section describes the extended functions available with the standard onboard LAN of the system unit, an optional LAN mezzanine and a LAN card. The network adapter, such as an onboard LAN or optional LAN of the system unit, can use the LAN extended functions such as network redundancy, load distribution, and confidential security. The following types of LAN extended functions are available: LAN device redundancy function Provides network redundancy and fault tolerance by combining two network adapters. In case of network connection failure, the failed network adapter is changed over to the backup adapter automatically to shift processing. LAN device load distribution function Provides expanded band width of a network by combining two network adapters. This function distributes the traffic load of transmit data to each adapter. Switch redundancy function Provides high reliability of a network by combining two network adapter with two switching hubs (current one and standby) supporting STP (IEEE802.1d) for the purpose of redundancy. Tag VLAN (IEEE802.1q VLAN) Provides logical segmentation by identify a VLAN group. VLAN group is identified according to an ID specified on a tag in a packet. These expansion functions are set from the LAN utility "Broadcom Advanced Control Suite 4" (BACS4). For details on how to use the LAN utility, see Windows Server 2008 R2 LAN Extended Functions User's Guide. System Unit Functions 3-29
54 3-30 System Unit Functions
55 4 Operational precautions This chapter describes operational precautions. Precautions on LAN controller Precautions on internal devices Operational precautions 4-1
56 Precautions on LAN controller This section describes precautions when using the standard onboard LAN of the system unit, and an optional LAN mezzanine and LAN card. TCP Checksum Offload function The standard onboard LAN of the system unit, LAN mezzanine (CN7M0T-Y/CN7M0T-R), and LAN card (CN7721-Y/CN7721-R/CN7723-Y/ CN7723-R/CN7741-Y/CN7741-R/CN7743-Y/CN7743-R) are equipped with a function for their LAN controller to perform TCP/IP protocol checksum calculations. However, we recommend not to use this function but to use the standard TCP/IP checksum calculation function of the OS. If the calculation by the OS is set up, the integrity of packet data received from a network will be checked in the final stage of protocol processing of the OS, thus enabling construction of a more reliable system. If you use the LAN mezzanine (CN7M1S-Y/CN7M1S-R/CN7M1T-Y/ CN7M1T-R) or the LAN card (CN7821-Y/CN7821-R/CN7823-Y/ CN7823-R/CN7841-Y/CN7841-R), do not change these settings. The network performance will be degraded. 4-2 Operational precautions
57 Setup method in Windows Server 2008 R2 1. Double-click Control Panel > Device Manager. 2. Open the Details tab page of the properties windows of each network adapter in Network adapters. 3. Change the settings according to the following table if the setup items are displayed: Table 4-1: Settings of network adapter properties Item settings Broadcom Advanced Control Suite 4 not installed Broadcom Advanced Control Suite 4 installed IPv4 Checksum Offload Rx & Tx Enabled -> None Rx & Tx Enabled -> None TCP/UDP Checksum Offload (lpv4) TCP/UDP Checksum Offload (lpv6) Rx & Tx Enabled -> None Rx & Tx Enabled -> None Rx & Tx Enabled -> None Rx & Tx Enabled -> None Large Send Offload (IPv4) Enable -> Disable Enable -> Disable Large Send Offload v2(ipv4) Enable -> Disable Enable -> Disable Large Send Offload v2(ipv6) Enable -> Disable Enable -> Disable Receive Side Scaling Enable -> Disable Enable -> Disable 4. After setting all items, click OK and restart the OS. Operational precautions 4-3
58 Precautions on internal devices This section describes precautions when using the internal devices of the system unit. SSD The built-in SSD is a storage device that uses a flash memory device as a semiconductor recording device. HDD adopts a system of magnetic recording on media but SSD uses a flash memory device as a nonvolatile semiconductor recording device. The SSD is excellent in random access performance, impact resistance and low power consumption. But the SSD has a write capacity limit. It is assumed that the write environment of a typical server is about 50 GB/day. The SSD might reach the maximum write capacity limit under an environment where a write operation is conducted frequently. If the defragmentation tool is used for SSD, it might be short life. SSD is different from HDD. Do not use the defragmentation tool on SSD. When the built-in SSD (MLC: Multiple Level Cell type) is near the end of life, the built-in SSD data is lost due to drained of recorded electric charge while powering off for a long time. SSD that is near the end of life notify the S.M.A.R.T.(Self-Monitoring, Analysis and Reporting Technology) error. Monitor the error of SSD using the RAID management utility. If the S.M.A.R.T. error is detected, change a new SSD for prevention. 4-4 Operational precautions
59 5 Maintenance and service parts This chapter describes daily maintenance procedures, service parts and consumables. Daily maintenance items Cleaning Service parts Consumables Maintenance and service parts 5-1
60 Daily maintenance items Both system unit and internal devices should be maintained periodically. Conduct daily maintenance according to the table below. If either system unit or internal devices are found abnormal during daily maintenance, contact the sales representative or maintenance personnel. For optional devices, see their individual manuals. Table 5-1: Maintenance items Location Cleaning or check item Cleaning or check cycle Clean Cleanup dust from the air vents 6 months* System unit Check Check ERROR and MAINTENANCE LEDs on the operational panel. 6 months Check fans for abnormal noise 6 months Internal DVD-ROM Clean Clean pickup lens with cleaning kits. In case of a media read error * If the system unit is used in a dusty environment, clean the unit once every month. Cleaning System unit This section describes how to clean the system unit and its standard devices. For the cleaning of other optional devices, see their individual manuals. For the following procedure, see Hitachi Compute Rack 220H Getting Started Guide together. NOTICE Turn off the system unit and disconnect the power cable whenever you clean the unit. Otherwise, a component failure can occur. Keep the system unit free of water. Do not wipe the unit with a wet cloth. Otherwise, a component failure can occur. 1. Power off the system unit. 2. Disconnect all the power cables from the outlet or the rear side of system unit. 3. Disconnect the interface cable from the system unit. 5-2 Maintenance and service parts
61 4. Clean dust off the following vents of the system unit with a dry cloth or vacuum cleaner. Figure 5-1: Cleanup location of the system unit 5. Before connection, remove dust from the connectors of interface cable and system unit using a dry cloth. 6. Wipe dust off the plug of the power cable and connect the cable to an outlet and system unit. Internal DVD-ROM Clean the pickup lens in case of a media read error. For purchasing a cleaning kit, contact the sales representative. For the cleaning method, obey the cleaning kit usage. Maintenance and service parts 5-3
62 Service parts The system unit is designed to have an estimated life of five years (when running 24 hours a day/30 days a month). Service parts that deteriorate and wear out during use are contained in the parts of the system unit. NOTICE Some of service parts use an aluminum solid electrolytic capacitor with a service life. An attempt to use such parts beyond their life will leak or exhaust their electrolytic solution, thus causing smoking or bad smell. To prevent these risks, replace service parts whenever exceeding their design life. Major service parts are as follows: Table 5-2: Service parts Part name Product code Remarks Internal DVD-ROM (Standard of system unit) *1 Notes: If the drive is used under the installation environment provided in Hitachi Compute Blade 2000/1000/320 and Hitachi Compute Rack 220/210 Site Planning Guide, the energization life time is approximately 13,000 hours. If the drive is used for 24 hours a day and for 30 days a month, its lifetime will be approximately 1.5 years. If the drive is used beyond the above environmental conditions, a failure might be caused or its life might be shortened. When the built-in SSD (MLC: Multiple Level Cell type) is near the end of life, the built-in SSD data is lost due to drained of recorded electric charge while powering off for a long time. SSD that is near the end of life notify the S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) error. Monitor the error of SSD using the RAID management utility. If the S.M.A.R.T. error is detected, change a new SSD for prevention. Lifetime is a rough estimate, which does not assure that those devices will not fail within this period of time. 5-4 Maintenance and service parts
63 Consumables For the consumables, contact the sales representative. NOTICE Use the specified consumables, such as data media and cleaning media. Otherwise, product reliability will deteriorate and a risk of failure increases. Maintenance and service parts 5-5
64 5-6 Maintenance and service parts
65 6 Troubleshooting This chapter describes troubleshooting of the system unit. Solving problems Corrective actions for error Troubleshooting 6-1
66 Solving problems This section describes how to take measures against various cases. Table 6-1: Solving problems No Description Point to be checked and action to be taken 1 Initial failure or missing part Check the system unit for missing parts or damage against the accessories checklist. After delivery, check the operation of system unit for initial failures. If initial failures or missing parts are found, contact the sales representative Some users do not know how to use equipment or have questions about manual's descriptions. System unit does not work normally or an error occurs. System unit infected with a computer virus. Want to change the disk array or know the operation of disk array See the documents of devices. For any questions on a manual's description, contact the sales representative. See Corrective actions for error on page 6-3. Disconnect the network cable and follows the instructions mentioned in the manual attached to your anti-virus software. Start setup with the RAID BIOS "MegaRAID WebBIOS". For details on the RAID BIOS, see Hitachi Compute Rack 210H/220H BIOS Guide. Also, see MegaRAID Storage Manage Instruction Manual. 6 Want to extend a function. 7 Others For addition of another optional device or software, contact the sales representative. For any other questions, contact the sales representative. 6-2 Troubleshooting
67 Corrective actions for error This section describes how to take action depending on the symptom of an error or a system unit failure. Specific problems and corrective actions This section lists problems that cause abnormal operation of the system unit or peripheral, and the actions to be taken. If the system does not recover from a failure even when the following actions are taken, contact the sales representative or maintenance personnel. Table 6-2: Problems and actions No Problems Point to be checked and action to be taken The POWER LED does not light. (The power is not turned on). Abnormal heat or smoke, or a short circuit occurred. An error message appears at the start time. The ERROR LED on the system unit lights. Memory capacity is smaller than the actual one. Internal device does not work (HDD, DVD-ROM). The keyboard is out of order, some of the keys are unusable, or the mouse does not work normally. Check if the AC cable is connected normally. See Hitachi Compute Rack 220H Getting Started Guide. Check if the POWER switch is set to ON. Turn off the power immediately and disconnect all the AC cables. Contact the sales representative or maintenance personnel. See When an error message appears on page 6-5. See Errors during use on page Check if memory is installed normally. See Hitachi Compute Rack 220H CRU Replacement Guide. The available memory capacity might decrease due to the effect of a memory hole. Check if the online spare memory function or memory mirroring function has been set valid. An attempt to use this function uses part or the half of memory, thus reducing the capacity. See Hitachi Compute Rack 210H/220H BIOS Guide. Check if internal devices are installed normally. See Hitachi Compute Rack 220H CRU Replacement Guide. Check if the system BIOS or RAID BIOS is set up normally. See Hitachi Compute Rack 210H/220H BIOS Guide. Check if the applicable drive has been installed. Check if the keyboard cable is connected normally or if the mouse cable is connected normally. See Hitachi Compute Rack 220H Getting Started Guide. 8 Serial port does not operate. Check if the system BIOS is set up normally. See Hitachi Compute Rack 210H/220H BIOS Guide. Troubleshooting 6-3
68 No Problems Point to be checked and action to be taken 9 Nothing appears on the display, or garbage appears on the screen. Check if the display's power switch is turned on, if the display's contrast or brightness control volume is adjusted properly, or if the power cable is normally connected to both display and outlet. Check if the display cable is normally connected to both display and system unit. See Hitachi Compute Rack 220H Getting Started Guide. 10 Abnormal window appears. 11 Only the mouse cursor appears. Check if precision equipment is installed around the system unit. Check if the system unit or display positions changed during its use. Geomagnetic effects or color shading might occur on the display. Turn off the power once and leave at least 30 minutes before restart. Check if the system unit is too close to the display. Keep the system unit properly distant from the display or increase the refresh rate setting. Any cause cannot be identified. Contact the sale representative, or maintenance personnel Anything appearing on the display is unreadable or distorted. Changed setup on the system BIOS cause abnormal operation. Use of other company's product causes abnormal operation. Check if the refresh rate is set beyond the display's specification. Return the settings on the system BIOS to factory defaults. See Hitachi Compute Rack 210H/220H BIOS Guide. Abnormal operation can be attributed to the other company's product. Ask the product manufacturer. 6-4 Troubleshooting
69 When an error message appears This section describes how to take action if an error message appears. When a system BIOS error message appears If an error is detected during POST, an error message appears on the display. Take action according to the description mentioned in the "Action" of the table below. If a message not described in the table should appear, write down the message and contact the sales representative or maintenance personnel. Table 6-3: System BIOS error messages during POST Error code Error message Description Action Last power event was caused by CPU1 Thermal Trip Last power event was caused by CPU2 Thermal Trip A processor error has been detected. A processor error has been detected CPU1 BIST Error is found A processor error has been detected CPU2 BIST Error is found A processor error has been detected FRU checksum bad A BMC error has been detected Cannot set BMC network configuration A BMC error has been detected BMC is not ready A BMC error has been detected Power supply configuration error A power supply configuration error has been detected. 3B01 System battery is dead A battery error has been detected. 3B02 Check date and time settings A system clock error has been detected. (*2) - BMC hard fail A BMC error has been detected. - BMC soft fail A BMC error has been detected. - BMC communication error A BMC error has been detected. - Cannot access SDR Repository A BMC error has been detected. - Cannot access BMC FRU device A BMC error has been detected. - IPMB Signal lines do not respond A BMC error has been detected. - SDR Repository empty A BMC error has been detected Internal Use Area of BMC FRU corrupted Controller updated 'boot block' firmware corrupted Controller operational firmware corrupted A BMC error has been detected. A BMC error has been detected. A BMC error has been detected. - BMC is in force update mode A BMC error has been detected ME Firmware has stopped A firmware error has been detected. Troubleshooting 6-5
70 Error code Error message Description Action 2631 BIOS and ME are not compatible A firmware error has been detected HECI is disabled A HECI error has been detected ME Status is Invalid A firmware error has been detected Cannot initialize HECI A HECI error has been detected Notes: Cannot enable Memory Mirroring Mode Cannot enable Memory Lock Step Mode Cannot enable Memory Sparing Mode A memory error has been detected. (*3) A memory error has been detected. (*3) A memory error has been detected. (*3) Contact the sales representative or maintenance personnel. (*2) Set correct information on the system BIOS setup menu. If an error recurs, contact the sales representative or maintenance personnel. (*3) Check if the memory boards are of correct configuration or installed normally. If an error recurs, contact the sales representative or maintenance personnel. When a RAID BIOS error message appears A RAID BIOS "MegaRAID WebBIOS" message might appear. Take action according to the description under "Action" in the table below. Table 6-4: RAID BIOS error messages during POST Error message Description Action Cache data was lost because of an unexpected power-off or reboot during a write operation, but the adapter has recovered. This could be because of memory problems, bad battery, or you may not have a battery installed. Press any key to continue or press C to load the configuration utility. The memory/battery problems were detected. The adapter was recovered, but cached data was lost. Press any key to continue or press C to load the configuration utility. Cache data was lost, but the controller has recovered. This could be due to the fact that your controller had protected cache after an unexpected power loss and your system was without power longer than the battery backup time. Press any key to continue or press C to load the configuration utility. If this message appears even though an illegal power shutdown or reboot is not conducted during write operation, contact the sales representative, or call maintenance personnel. If this message appears even though an illegal power shutdown or reboot is not conducted during write operation, contact the sales representative, or call maintenance personnel. If this message appears even though an illegal power shutdown or reboot is not conducted during write operation, contact the sales representative, or call maintenance personnel. 6-6 Troubleshooting
71 Error message Description Action The cache contains dirty data, but some VDs are missing. The cached data cannot be written to the disk. If this is an unexpected error, then power off your system and check your cables to ensure all disks are present. If you continue, the data in the cache will be permanently discarded. Press X to acknowledge and permanently destroy the cached data. Foreign configurations found on adapter. Press any key to continue or press C to load the configuration utility. The battery hardware is missing or malfunctioning, the battery is unplugged, or the battery could be fully discharged. If you continue to boot the system, the battery-backed cache will not function. If the battery is connected and has been allowed to charge for 30 minutes and if this message continues to appear, contact technical support for assistance. Press D to disable this warning (if your controller does not have a battery). The battery hardware is missing or malfunctioning, the battery is unplugged, or the battery could be fully discharged. If you continue to boot the system, the battery-backed cache will not function. If the battery is connected and has been allowed to charge for 30 minutes and if this message continues to appear, contact technical support for assistance. Some configured disks have been removed from your system, or are no longer accessible. Check your Cables and also ensure all disks are present. Press any key to continue or press C to load the Configuration utility. The following VDs have missing disks: - If you proceed (or load the configuration utility), these VDs will be marked OFFLINE and will be inaccessible. - Check your cables and ensure all disks are Present. Press any key to continue or press C to load the configuration utility. A discovery error has occurred. Power-cycle the system and all the enclosures attached to this system. If this message appears even though an illegal power shutdown or reboot is not conducted during write operation, contact the sales representative, or call maintenance personnel. Some HDDs found in the disk array controller do not match the disk array configuration information. Cache backup module information is not set correctly. Press D while this message is appearing. Cache backup module information is not set correctly. Press D while this message is appearing. Some HDDs with the disk array configuration information have been removed. The disk array is set to OFFLINE because some HDDs have been removed. The disk array or HDDs were not recognized correctly. (*2) (*3) (*3) (*4) (*4) Troubleshooting 6-7
72 Error message Description Action The following VDs are missing: If you proceed (or load the configuration utility), these VDs will be removed from your configuration. If you wish to use them at a later time, they will have to be imported. If you decide these VDs should be present, power off your system and check your cables to ensure all disks are present. Press any key to continue or press C to load the configuration utility. The following VDs are missing complete spans. If you proceed (or load the configuration utility), these VDs will be removed from your configuration and the remaining drives marked as foreign. If you wish to use them at a later time, restore the missing spans and use foreign import to recover the VDs. If you believe these VDs should be present, please power off your system and check your cables to ensure all disks are present. Press any key to continue, or 'C' to load the configuration utility. All of the disks from your previous configuration are gone. If this is an unexpected message, then power off your system and check your cables to ensure all disks are present. Press any key to continue or press C to load the configuration utility. Your battery is either charging, bad, or missing and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs will actually run in the write-through mode until the battery is fully charged or replaced if it is bad or missing. Press any key to continue. Multibit ECC errors were detected on the RAID controller. The DIMM on the controller needs replacement. Contact technical support to resolve this issue. If you continue, data corruption can occur. Press X to continue or else power off the system and replace the DIMM module and reboot. If you have replaced the DIMM press X to continue. Some of the disk array configurations have been removed. Some of the disk array configurations have been removed. All the HDDs with the disk array configuration information have been removed. Cache backup module information is illegal. A cache memory error has occurred in the disk array controller. (*4) (*4) (*4) 6-8 Troubleshooting
73 Error message Description Action Single-bit ECC errors were detected during the previous boot of the RAID controller. The DIMM on the controller needs replacement. Contact technical support to resolve this issue. Press X to continue or else power off the system and replace the DIMM module and reboot. If you have replaced the DIMM press X to continue. Single-bit overflow ECC errors were detected during the previous boot of the RAID controller. The DIMM on the controller needs replacement. Contact technical support to resolve this issue. If you continue, data corruption can occur. Press X to continue or else power off the system and replace the DIMM module and reboot. If you have replaced the DIMM press X to continue. Single-bit overflow ECC errors were detected during the previous boot of the controller. The DIMM on the controller needs replacement. If you continue, data corruption can occur. Press X to continue or else power off the system and replace the DIMM module and reboot. If you have replaced the DIMM press X to continue. Multibit ECC errors were detected on the RAIDcontroller. If you continue, data corruption can occur. Contact technical support to resolve this issue. Press X to continue or else power off the system, replace the controller and reboot. Multiple Single-bit ECC errors were detected during the previous boot of the controller. The DIMM on the controller needs replacement. If you continue, data corruption can occur. Press X to continue or else power off the system, replace the DIMM module, and reboot. If you have replaced the DIMM, press X to continue. Single-bit overflow ECC errors were detected on the RAID controller. If you continue, data corruption can occur. Contact technical support to resolve this issue. Press X to continue or else power off the system, replace the controller and reboot. A cache memory error has occurred in the disk array controller. A cache memory error has occurred in the disk array controller. A cache memory error has occurred in the disk array controller. A cache memory error has occurred in the disk array controller. A cache memory error has occurred in the disk array controller. A cache memory error has occurred in the disk array controller. Troubleshooting 6-9
74 Error message Description Action Memory Error. Please check the SDRAM connection. If problems persist contact Tech Support. Memory Error. Detected Unsupported RAID Controller Memory. Contact Tech support. Unrecoverable Error. Please check the SDRAMconnection. If problems persist contact Tech Support. A cache memory error has occurred in the disk array controller. A cache memory error has occurred in the disk array controller. A cache memory error has occurred in the disk array controller. This is a TEST message. Press any key to ignore it, or wait 5 seconds. No further action is required. Press any key to continue, or C to load the configuration utility. This firmware is an ALPHA version. It has not completed all validation. This firmware is a BETA version. It has not completed all validation. This firmware is a TEST version. It has not completed any validation. Test message The firmware is of alpha version. The firmware is of beta version. The firmware is of test version. The firmware version inconsistency was detected. The adapter was recovered, but cached data was lost. Press any key to continue or press C to load the configuration utility. Firmware Failed Validation. Adapter needs to be refreshed. The most recent configuration command could not be committed and must be retried. Press any key to continue, or press C to load the configuration utility. Previous configuration cleared or missing. Importing configuration created on X/Y X:Y Press any key to continue or press C to load the configuration utility. An enclosure was found that contains both SAS and SATA drives, but this controller does not allow mixed drive types in a single enclosure. Correct the problem and restart your system. Press any key to continue or press C to load the configuration utility. SAS drives were detected, but this controller does not support SAS drives. Remove the SAS drives and restart your system. Press any key to continue or press C to load the configuration utility. Firmware version inconsistency has been detected. Firmware version inconsistency has been detected. The disk array configuration information has been cleared or missing. The disk array configuration information has been cleared or missing. The disk array controller is working with illegal parameters. The disk array controller is working with illegal parameters Troubleshooting
75 Error message Description Action SATA drives were detected, but this controller does not support SATA drives. Remove the SATA drives, and restart your system. Press any key to continue or press C to load the configuration utility. Raid Key Missing. Please check the Raid Key connection. If problems persist contact Tech Support. Raid Key Authentication Error. Please check the RAID Key installed for this solution. If problems persist, contact Tech Support. Raid Key OEM Authentication Error. Install the correct RAID key for this System. If problems persist contact Tech Support. The disk array controller is working with illegal parameters. The disk array controller is working with illegal parameters. The disk array controller is working with illegal parameters. The disk array controller is working with illegal parameters. There are more enclosures connected to the port than what is allowed for a single SAS port. Remove the extra enclosures, and then restart your system. An illegal enclosure has been detected. Invalid SAS topology detected. Check your cable configurations, repair the problem, and restart your system. An invalid SAS topology has been detected. Invalid SAS Address present in SBR. Contact your system support. Press any key to continue with the default SAS address. Invalid SAS Address present in MFC data. Program the valid SAS Address, and restart your system. An invalid SAS address exists. An invalid SAS address exists. Invalid memory configuration detected. Contact your system support. System has halted. Entering the configuration utility in this state will result in drive configuration changes. Press Y to continue loading the configuration utility or power off your system and check your cables to ensure that all the disks are present, and then restart. External Enclosure does not support in controller's Direct mapping mode. Contact your system support. System has halted due to unsupported configuration. Expander Detected in controller with Direct mapping mode. Reconfiguring automatically to persistent mapping mode. Automatic reboot would happen in 10 seconds. Invalid memory configuration information has been detected. The HDD configuration information has been changed. Illegal information has been detected from the enclosure. An unsupported device (expander) has been detected. Troubleshooting 6-11
76 Error message Description Action The controller's I/O processor has a fault that can potentially cause data corruption. Your controller needs replacement. Contact your system support. Press Y to acknowledge. The disk array controller's processor is illegal. Number of disks exceeded the maximum supported count of X disks. Remove the extra drives and reboot the system to avoid losing data. Press Y to continue with extra drives. Number of devices exceeded the maximum limit of devices per quad. Remove the extra drives and reboot the system to avoid losing data. System has halted due to unsupported configuration. An illegal HDD has been detected. An illegal HDD has been detected. Drive security is enabled on this controller and a pass phrase is required. Please enter the pass phrase. Invalid pass phrase. Please enter the pass phrase. There was a drive security key error. All secure drives will be marked as foreign. Press any key to continue, or C to load the configuration utility. Invalid pass phrase. If you continue, there will be a drive security key error and all secure configurations will be marked as foreign. Reboot the machine to retry the pass phrase or press any key to continue. Unable to communicate to EKMS. If you continue, there will be a drive security key error and all secure configurations will be marked as foreign. Please check connection with the EKMS, reboot the machine to retry the EKMS or press any key to continue. Unable to change security to EKMS was not able to communicate to EKMS. If you continue, the drive security will remain to existing security mode. Please check connection with the EKMS, reboot the machine to retry the EKMS or press any key to continue. DKM existing key request failed; existing secure configurations will be labeled foreign and will not be accessible. Reboot server to retry. DKM new key request failed; controller security mode transition was not successful. Reboot server to retry request, or press any key to continue. The HDD security function is not supported. The HDD security function is not supported. The HDD security function is not supported. The HDD security function is not supported. The HDD security function is not supported. The HDD security function is not supported. The HDD security function is not supported. The HDD security function is not supported Troubleshooting
77 Error message Description Action The native configuration is no longer supported by the current controller settings. Please ensure that correct controller, ibutton or key vault is being used. If you continue, the configuration will be marked foreign and part of it may be imported if possible. Press any key to continue. The battery is currently discharged or disconnected. Verify the connection and allow 30 minutes for charging. If the battery is properly connected and it has not returned to operational state after 30 minutes of charging, contact technical support for additional assistance. Press D to disable this warning (if your controller does not have a battery). The battery is currently discharged or disconnected. VDs configured in write-back mode will run in write-through mode to protect your data, and will return to write-back policy when the battery is operational. If VDs have not returned to write-back mode after 30 minutes of charging then contact technical support for additional assistance. The following VD is affected: X. Press any key to continue. Two BBUs are connected to the adapter. This is not a supported configuration. Battery and caching operations are disabled. Remove one BBU and reboot to restore battery and caching operations. If dirty cache is lost in this boot, that could have been because of dual battery presence. Firmware did not find valid NVDATA image. Program valid NVDATA image and restart your system. Press any key to continue. The original configuration information is not supported for setup of the disk array controller. The cache backup module information is illegal. The cache backup module information is illegal. The cache backup module information is illegal. Firmware did not find valid NVDATA image. Program valid NVDATA image and restart your system. Press any key to continue. IR to MR Migration failed. Press any key to continue with MR defined NVDATA values. There are offline or missing virtual drives with preserved cache. Check the cables and ensure that all drives are present. Press any key to enter the configuration utility. There are offline or missing virtual drives with preserved cache. Check the cables and ensure that all drives are present. Migration is not supported. No logical drive is found. No logical drive is found. Troubleshooting 6-13
78 Error message Description Action Incompatible secondary ibutton present! Please insert the correct ibutton and restart the system. Press any key to continue but OEM-specific features will not be upgraded. Upgrade Key Missing! An upgrade key was present on a previous power cycle, but it is not connected. This can result in inaccessible data unless it is addressed. Reattach the upgrade key and reboot. ibutton is illegal. An upgrade key is not supported. Serial Boot ROM(SBR) device is corrupt or bad. Please contact Tech Support. Serial Boot ROM (SBR) device malfunction Notes: Contact the sales representative or maintenance personnel. (*2) Set correct information on the RAID BIOS "MegaRAID WebBIOS". (*3) If the system does not recover from the problem, contact the sales representative or maintenance personnel. (*4) If this message appears with the device installed normally, contact the sales representative or maintenance personnel Troubleshooting
79 When a beep sounds When an error occurs before the display is initialized, the system unit sounds a beep. When the Power On Self Test ends, a beep sounds once but this is not an error. In this table below, beep is expressed as "1-1-1 ", for example. This means a beep sounds once with intervals. Table 6-5: Beep sounds Beep Error Action (Sounds continuously) Memory error Contact the Sales representative or maintenance personal. Errors at the time of boot from HDD The following messages might appear if the OS fails to boot the system unit after POST during system startup: Insert bootable media in the appropriate drive Missing OS OS not found If the above messages appear, verify the setup of the system BIOS or RAID BIOS. See Hitachi Compute Rack 210H/220H BIOS Guide. If the system does not recover, the boot information storage area of the HDD might be destroyed. Re-install the OS. If the OS cannot be booted after re-installation, replace the HDD. In this case, contact the sales representative or maintenance personnel. Troubleshooting 6-15
80 Errors during use This section describes how to handle an error during system use. Table 6-6: Errors during use Error symptom Description Measures ERROR LED lights* ERROR LED lights* + HDD status LED lights amber ERROR LED lights* + Power supply LED lights amber Power supply LED blinks amber Abnormal temperature inside the system unit. Alternately, a failure has occurred in the hardware such as fans or the mother board inside the system unit. A failure has occurred on the internal HDD/SSD. A power supply failure has occurred. A power supply is warning status. Review the ambient temperature range of the system unit and make an adjustment so as to keep a temperature within the allowable range. Remove dirt from the vent at the front and rear of the system unit in order to improve emissions. If the ERROR LED is still lit, contact the sales representative or maintenance personnel. Replace the HDD/SSD. Contact the sales representative or maintenance personnel. Replace the power supply. Contact the sales representative or maintenance personnel. Review the ambient temperature range of the system unit and make an adjustment so as to keep a temperature within the allowable range. Remove dirt from the vent at the front and rear of the system unit in order to improve emissions. If the power supply LED is still blinks amber, contact the sales representative or maintenance personnel. * When the ERROR LED lights, the MAINTENANCE LED's event code indicator denotes what hardware an error has occurred in. See MAINTENANCE LEDs on page Troubleshooting
81
82 Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California U.S.A. Regional Contact Information Americas Europe, Middle East, and Africa +44 (0) Asia Pacific MK-90CRH003-02
Hitachi Compute Blade 500 Series NVIDIA GPU Adapter User s Guide
Hitachi Compute Blade 500 Series NVIDIA GPU Adapter User s Guide FASTFIND LINKS Getting Help Contents MK-91CB500083-01 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced
Hitachi Virtual Storage Platform G1000
Hitachi Virtual Storage Platform G1000 Encryption License Key User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92RD8009-02 2014 Hitachi, Ltd. All rights reserved. No part of this publication
Hitachi Data Ingestor
Hitachi Data Ingestor Backup Restore Features Supplement for Hitachi Data Protection Suite Product Version Getting Help Contents MK-90HDI009-14 2010-2015 Hitachi, Ltd. All rights reserved. No part of this
Tuning Manager. Hitachi Command Suite. Server Administration Guide MK-92HC021-38. FASTFIND LINKS Document Organization. Product Version.
Hitachi Command Suite Tuning Manager Server Administration Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-92HC021-38 2015 Hitachi, Ltd. All rights reserved. No part
This chapter explains how to update device drivers and apply hotfix.
MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview
Compute Systems Manager
Hitachi Command Suite Compute Systems Manager Installation and Configuration Guide MK-91HC195-12 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Encryption License Key User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7015-10 2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication
Using GIGABYTE Notebook for the First Time
Congratulations on your purchase of the GIGABYTE Notebook! This Manual will help you to get started with setting up your notebook. For more detailed information, please visit our website at http://www.gigabyte.com.
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Data Retention Utility User s Guide
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Data Retention Utility User s Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD612-03
Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool OS Setup Guide
Hitachi Compute Blade Series Hitachi Compute Rack Series FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-99COM061-07 2012-2015 Hitachi, Ltd. All rights reserved. No part of
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma
Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma FASTFIND LINKS Document Organization Product Version
Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)
PRIMERGY RX300 S2 Onboard SCSI RAID User s Guide Areas Covered Chapter 1 Features (Overview/Note) This chapter explains the overview of the disk array and features of the SCSI array controller. Chapter
Compute Systems Manager
Hitachi Command Suite Compute Systems Manager User Guide MK-91HC194-10 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,
NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later
NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later 856-127900-613-G 7th Edition Jun. 2015 Copyright NEC Corporation 2015. Trademarks NEC EXPRESSBUILDER is trademarks of NEC Corporation.
Hitachi Application Protector Version 1.2 for SAP Release Notes
Hitachi Application Protector Version 1.2 for SAP Release Notes Copyright Information... 2 Product Release Information... 4 Introduction... 4 Installation and Configuration Notes... 4 Manifest... 4 Minimum
RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card.
RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card. 1 Contents 3 RAID Utility User s Guide 3 Installing the RAID Software 4 Running
Hitachi NAS Blade for TagmaStore Universal Storage Platform and Network Storage Controller NAS Blade Error Codes User s Guide
Hitachi NAS Blade for TagmaStore Universal Storage Platform and Network Storage Controller NAS Blade Error Codes User s Guide MK-95RD280-03 2006 Hitachi, Ltd., Hitachi Data Systems Corporation, ALL RIGHTS
RAID installation guide for Silicon Image SiI3114
RAID installation guide for Silicon Image SiI3114 Contents Contents 2 1 Introduction 4 1.1 About this Guide 4 1.2 The Basics 4 1.2.1 What is RAID? 4 1.2.2 Advantages of RAID 4 1.2.3 Disadvantages of RAID
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Configurations...3 2.1 Introduction
MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement
MaxAttach NAS 4000 Series MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement DOCUMENT OVERVIEW Who Should Use This Instruction Set This MaxAttach NAS 4000 Series by Maxtor HDD Replacement Instruction
NVIDIA RAID Installation Guide
NVIDIA RAID Installation Guide 1. NVIDIA BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID. 2 1.2 RAID Configurations Precautions.. 3 1.3 Create Disk Array. 4 2. NVIDIA Windows RAID Installation
RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009
RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009 Copyright Protected Material 2009. All rights reserved. All other trademarks and registered trademarks are proprietary to their respective
RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card
RAID Utility User Guide Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card Contents 3 RAID Utility User Guide 3 The RAID Utility Window 4 Running RAID Utility
3.5 Dual Bay USB 3.0 RAID HDD Enclosure
3.5 Dual Bay USB 3.0 RAID HDD Enclosure User Manual August 11, 2011 v1.1 MFG Part # MT2U3-MP BARCODE Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Performance Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7020-12 2010-2013 Hitachi Ltd. All rights reserved. No part of this
Using GIGABYTE Notebook for the First Time
Congratulations on your purchase of the GIGABYTE Notebook. This manual will help you to get started with setting up your notebook. The final product configuration depends on the model at the point of your
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Confi gurations...3 2.1 Introduction
ARAID 3500 / S3500 User s Manual
1 Model 3500 / S3500 User s Manual Revision A Table of Contents Thank you for purchasing ARAID 3500 / S3500... 2 Mobile Racks... 5 ARAID 3500 / S3500 Features... 4 SPECIFICATIONS... 4 SYSTEM REQUIREMENTS...
PCI-to-SATA RAID Adapter AEC-6890M. User s Manual Version:1.0
PCI-to-SATA RAID Adapter AEC-6890M User s Manual Version:1.0 Copyright 2003 ACARD Technology Corp. Release: August 2003 Copyright and Trademarks The information of the product in this manual is subject
Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer
Configuring ThinkServer RAID 500 and RAID 700 Adapters Lenovo ThinkServer October 4, 2011 Contents Overview... 4 RAID 500 features... 4 RAID 700 features... 4 RAID Overview... 4 Choosing the RAID Level...
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Using GIGABYTE Notebook for the First Time
P34 V6.0 Congratulations on your purchase of the GIGABYTE Notebook. This manual will help you to get started with setting up your notebook. The final product configuration depends on the model at the point
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Configurations...3 2.1 Introduction
Hitachi Command Suite. Dynamic Link Manager. (for Windows ) User Guide. Document Organization. Product Version. Getting Help. Contents MK-92DLM129-30
Hitachi Command Suite Dynamic Link Manager (for Windows ) User Guide Document Organization Product Version Getting Help Contents MK-92DLM129-30 2014 Hitachi, Ltd. All rights reserved. No part of this publication
Performance Monitoring User s Manual
NEC Storage Software Performance Monitoring User s Manual IS025-15E NEC Corporation 2003-2010 No part of the contents of this book may be reproduced or transmitted in any form without permission of NEC
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Using RAID Admin and Disk Utility
Using RAID Admin and Disk Utility Xserve RAID Includes instructions for creating RAID arrays and monitoring Xserve RAID systems K Apple Computer, Inc. 2003 Apple Computer, Inc. All rights reserved. Under
Ultra ATA 133 RAID PCI Pro
Ultra ATA 133 RAID PCI Pro 1-1 Introduction Quick Installation Guide This ultra high-speed dual channel Ultra ATA/133 RAID controller is designed to support RAID 0, 1, 0+1 and JBOD. RAID configurations
Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma
Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma FASTFIND LINKS Document Organization Product Version
PCI SATA Controller Card Model: SY-PCI40010
SY-PCI40010 1 PCI SATA Controller Card Model: SY-PCI40010 User Manual Ver. 2.00 Chipset: Silicon Image SIL3124 SY-PCI40010 2 Product Introduction The Silicon Image Sil3124 Serial ATA I/II to PCI-X32/64-bit
System Release Notes Express5800/320LB System Release Notes
System Release Notes Express5800/320LB System Release Notes PN: 455-01681-004 2 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related
actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide
actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide Page 1 of 11 Introduction This poster describes how to install your ActiTape LTO half-height internal tape drives with SCSI and SAS interface.
Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0
4-Bay RAID Storage Enclosure User Manual January 16, 2009 - v1.0 EN Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC Requirements... 1 1.1.2 Mac Requirements... 1 1.1.3 Supported
HighPoint RAID Management User s Guide
HighPoint RAID Management User s Guide Revision: 1.0 Date: August 2009 HighPoint Technologies, Inc. HighPoint RAID Management User s Guide 1 - HighPoint RAID Management Utilities (HRM) Installation The
Hitachi Command Suite. Tuning Manager. Installation Guide. Document Organization. Product Version. Getting Help. Contents MK-96HC141-27
Hitachi Command Suite Tuning Manager Installation Guide Document Organization Product Version Getting Help Contents MK-96HC141-27 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Dynamic Provisioning User s Guide
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Dynamic Provisioning User s Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD641-07 Copyright
EMC RepliStor for Microsoft Windows ERROR MESSAGE AND CODE GUIDE P/N 300-002-826 REV A02
EMC RepliStor for Microsoft Windows ERROR MESSAGE AND CODE GUIDE P/N 300-002-826 REV A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2003-2005
PROMISE ARRAY MANAGEMENT (PAM) for
PROMISE ARRAY MANAGEMENT (PAM) for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Version 1.1 PAM for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Copyright 2004 Promise Technology, Inc. All
5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual
5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75511R/VPMA-75511R) Operates... 1 1-1 SteelVine
VIA RAID Installation Guide
VIA RAID Installation Guide 1 VIA BIOS RAID Installation Guide.... 3 1.1 Introduction of RAID... 3 1.2 RAID Configuration Precautions... 3 1.3 BIOS Configuration Utility.. 4 1.3.1 Enter BIOS Configuration
RAID Technology Overview
RAID Technology Overview HP Smart Array RAID Controllers HP Part Number: J6369-90050 Published: September 2007 Edition: 1 Copyright 2007 Hewlett-Packard Development Company L.P. Legal Notices Copyright
Using GIGABYTE Notebook for the First Time
P55 V3.0 Congratulations on your purchase of the GIGABYTE Notebook. This manual will help you to get started with setting up your notebook. The final product configuration depends on the model at the point
GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4
1 Table of Contents GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4 XD5 FAMILULARIZATION... 5 PACKAGE CONTENTS... 5 HARDWARE
Configuring ThinkServer RAID 100 on the TS140 and TS440
Configuring ThinkServer RAID 100 on the TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES
SATA RAID Function (Only for chipset Sil3132 used) User s Manual
SATA RAID Function (Only for chipset Sil3132 used) User s Manual 12ME-SI3132-001 Table of Contents 1 WELCOME...4 1.1 SATARAID5 FEATURES...4 2 AN INTRODUCTION TO RAID...5 2.1 DISK STRIPING (RAID 0)...5
Using GIGABYTE Notebook for the First Time
Congratulations on your purchase of the GIGABYTE Notebook. This manual will help you to get started with setting up your notebook. The final product configuration depends on the model at the point of your
5-BAY RAID STATION. Manual
5-BAY RAID STATION Manual Content 1. Features 3 1.1 Overview 3 1.2 SATA features 3 1.3 USB features 4 2. Specifications 4 3. System requirements 4 4. The device at a glance 4 4.1 Rear panel 5 4.2 The LED
Intel RAID Controllers
Intel RAID Controllers Best Practices White Paper April, 2008 Enterprise Platforms and Services Division - Marketing Revision History Date Revision Number April, 2008 1.0 Initial release. Modifications
ITE RAID Controller USER MANUAL
ITE RAID Controller USER MANUAL 120410096E1N Copyright Copyright 2004. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated
BounceBack Server Solution Reference Guide
BounceBack Server Solution Reference Guide Contents Introduction... 2 System Requirements... 3 Initial Setup... 4 BounceBack Server Appliance Front View... 5 BounceBack Server Appliance Rear View... 6
VIA / JMicron RAID Installation Guide
VIA / JMicron RAID Installation Guide 1. Introduction to VIA / JMicron RAID Installation Guide. 3 2. VIA RAID Installation Guide. 3 2.1 VIA BIOS RAID Installation Guide.. 3 2.1.1 Introduction of RAID.
SATARAID5 Serial ATA RAID5 Management Software
SATARAID5 Serial ATA RAID5 Management Software Home Edition Preliminary Draft Subject to Change Without Notice 05/7/04 Silicon Image, Inc. 1060 East Arques Ave. Sunnyvale CA 94085 (408) 616-4000 www.siliconimage.com
SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay
SoftRAID 5 QUICK START GUIDE for OWC ThunderBay TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.2 FEATURES 1.3 ABOUT THIS MANUAL SYSTEM SETUP...2 2.1 GETTING STARTED 2.2 INITIALIZING,
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,
2» 10» 18» 26» PD3 34 00 42»
» STARDOM Safe Capsule Series User Manual... 2» STARDOM Safe Capsule Serie Bedienungsanleitung... 10» Série STARDOM Safe Capsule Manuel de l utilisateur... 18 26 PD3500 34» Manual de usuario de STARDOM
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
RAID installation guide for ITE8212F
RAID installation guide for ITE8212F Contents Contents 2 1 Introduction 3 1.1 About this Guide 3 1.2 The Basics 3 1.2.1 What is RAID? 3 1.2.2 Advantages of RAID 3 1.2.3 Disadvantages of RAID 3 1.3 Different
Hitachi Command Suite. Automation Director. Installation and Configuration Guide MK-92HC204-00
Hitachi Command Suite Automation Director Installation and Configuration Guide MK-92HC204-00 2015 Hitachi, Ltd. All rights reserved No part of this publication may be reproduced or transmitted in any form
Serial ATA RAID PCI. User's Manual
Serial ATA RAID PCI User's Manual Chapter 1 Introduction Table of Contents 1-1 Features and Benefits. 1 1-2 System Requirements. 1 Chapter 2 RAID Arrays 2-1 RAID Overview.. 2 2-1.1 RAID 0 (striping)...
Using GIGABYTE Notebook for the First Time
Congratulations on your purchase of the GIGABYTE Notebook P7! This Manual will help you to get started with setting up your notebook. For more detailed information, please visit our website at http://www.gigabyte.com.
A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 16 Fixing Windows Problems
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 16 Fixing Windows Problems Objectives Learn what to do when a hardware device, application, or Windows component gives a problem Learn what to do
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction
Hydra Super-S LCM. 4-Bay RAID Storage Enclosure for four 3.5-inch Serial ATA Hard Drives. User Manual August 18, 2011 - v1.0 www.akitio.
Hydra Super-S LCM 4-Bay RAID Storage Enclosure for four 3.5-inch Serial ATA Hard Drives User Manual August 18, 2011 - v1.0 www.akitio.com EN Hydra Super-S LCM Table of Contents Table of Contents 1 Introduction...
Maintenance Best Practices for Adaptec RAID Solutions
Maintenance Best Practices for Adaptec RAID Solutions Note: This document is intended to provide insight into the best practices for routine maintenance of Adaptec RAID systems. These maintenance best
Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature
Table of Content Error Messages List... 2 Troubleshooting the Storage System... 3 I can t access the Manager... 3 I forgot the password for logging in to the Manager... 3 The users can t access the shared
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card User Manual Model: UGT-ST644R All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction...
DF-7506 1-to-2 SATA II RAID Box
DF-7506 1-to-2 SATA II RAID Box Version 1.0 Table of Contents Chapter 1 Product Introduction...3 1.1 Features...3 1.1.1 Shipping Package Content...3 1.2 Front View...4 1.3 Rear View...6 1.4 Disk Drive
Cautions When Using BitLocker Drive Encryption on PRIMERGY
Cautions When Using BitLocker Drive Encryption on PRIMERGY July 2008 Fujitsu Limited Table of Contents Preface...3 1 Recovery mode...4 2 Changes in hardware configurations...5 3 Prior to hardware maintenance
RAID OPTION ROM USER MANUAL. Version 1.6
RAID OPTION ROM USER MANUAL Version 1.6 RAID Option ROM User Manual Copyright 2008 Advanced Micro Devices, Inc. All Rights Reserved. Copyright by Advanced Micro Devices, Inc. (AMD). No part of this manual
RAID technology and IBM TotalStorage NAS products
IBM TotalStorage Network Attached Storage October 2001 RAID technology and IBM TotalStorage NAS products By Janet Anglin and Chris Durham Storage Networking Architecture, SSG Page No.1 Contents 2 RAID
Configuring ThinkServer RAID 100 on the Lenovo TS130
Configuring ThinkServer RAID 100 on the Lenovo TS130 Contents Overview 02 Embedded RAID 100 features on TS130 02 RAID Overview 02 Choosing the RAID Level 02 RAID 0 02 RAID 1 03 Configuring RAID 03 BIOS
Mini-EPic System of RAID
Mini-EPICa USB/IEEE 1394-to-SATA II RAID Subsystem Revision 1.2 Contents Preface... 3 Before You Begin... 4 Chapter 1 Introduction... 6 1.1 Technical Specification... 7 1.2 Identifying Parts of the RAID
Using AORUS Notebook for the First Time
V2.0 Congratulations on your purchase of the AORUS Notebook! This Manual will help you to get started with setting up your notebook. For more detailed information, please visit our website at http://www.aorus.com.
Contents. Overview. Drive Policy RAID 500 features. Disable BGI RAID 700 features. Management Tasks Choosing the RAID Level.
Configuring ThinkServer RAID 500 and RAID 700 Adapters Contents Overview 2 Drive Policy 28 RAID 500 features 2 Disable BGI 28 RAID 700 features 2 Adapter Properties 28 RAID Overview 2 Management Tasks
Manual IB-3620 Series
IB-RD3620SU3 1 IB-3620U3 CONTENT 1. Introduction... 3 1.1 General Information... 3 2. Hardware IB-3620 Series... 4 2.1 LED Indication / Button Front Panel... 4 2.2 Rear View... 5 3. HDD Installation...
USB3.0/eSATA/1394b-to-SATA II RAID SUBSYSTEM
USB3.0/eSATA/1394b-to-SATA II RAID SUBSYSTEM Revision 1.0 Contents Preface... 3 Before You Begin... 4 Chapter 1 Introduction... 6 1.1 Technical Specification... 7 1.2 Identifying Parts of the RAID Subsystem...
ATTO ExpressSAS Troubleshooting Guide for Windows
ATTO ExpressSAS Troubleshooting Guide for Windows This document describes troubleshooting techniques that can be used to identify and resolve issues associated with the ATTO ExpressSAS Raid Controller.
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2011 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft and Windows are U.S. registered trademarks
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting
HP Embedded SATA RAID Controller
HP Embedded SATA RAID Controller User Guide Part number: 433600-001 First Edition: June 2006 Legal notices Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject
IBM Europe Announcement ZG08-0232, dated March 11, 2008
IBM Europe Announcement ZG08-0232, dated March 11, 2008 IBM System x3450 servers feature fast Intel Xeon 2.80 GHz/1600 MHz, 3.0 GHz/1600 MHz, both with 12 MB L2, and 3.4 GHz/1600 MHz, with 6 MB L2 processors,
Hitachi NAS Platform F
Hitachi NAS Platform F Plug-in for VMware vsphere Administrator's Guide Product Version Getting Help Contents MK-92NAS072-03 2013-2015 Hitachi, Ltd. All rights reserved. No part of this publication may
SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1
SiS 180 S-ATA User s Manual Quick User s Guide Version 0.1 Edition April 2003 Copyright Trademarks SiS is a registered trademark of Silicon Integrated Systems Corp. All brand or product names mentioned
IBM ^ xseries ServeRAID Technology
IBM ^ xseries ServeRAID Technology Reliability through RAID technology Executive Summary: t long ago, business-critical computing on industry-standard platforms was unheard of. Proprietary systems were
Hardware Information Managing your server, adapters, and devices ESCALA POWER5 REFERENCE 86 A1 00EW 00
86 A1 00EW 00 86 A1 00EW 00 Table of Contents Managing your server, adapters, and devices...1 Managing your server using the Hardware Management Console...1 What's new...1 Printable PDFs...2 HMC concepts
ESATA PCI CARD. User s Manual
ESATA PCI CARD User s Manual Introduction... 3 System Requirements... 3 RAID Introduction... 3 BIOS Configuration Utility... 5 Configuring Arrays... 5 RAID Mode Definitions... 5 BIOS Configuration Utility...
HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001
HP dx5150 RAID Installation and Setup Guide Version 1.10 Document Part Number: 403571-001 July 2005 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject