Operating instructions Pump FZ-B
|
|
|
- Shanon O’Neal’
- 9 years ago
- Views:
Transcription
1 Operating instructions Pump FZ-B INDEX Page 1. General Safety A Pump type... 5 B Number of outlets... 5 C Inspection... 5 D Kinds of drive E Position of drive... 9 F Reservoir G Accessories Application Principle of operation Rotational direction of drive Specifications Start-up Maintenance Plates Manufacturer s declaration page 1 of 15
2 1. General Prior to start up, we recommend to read these operating instructions carefully as we do not assume any liability for damages and operating troubles which result from the nonobservance of these operating instructions! Any use beyond the applications described in these operating instructions is considered to be not in accordance with the product s intended purposes. The manufacturer is not to be held responsible for any damages resulting from this: the user alone bears the corresponding risk. As to figures and indications in these operating instructions we reserve the right to make technical changes which might become necessary for improvements. The copyright on these operating instructions is kept reserved to the company DELIMON. These operating instructions are intended for the erecting, the operating and supervising personnel. They contain regulations and drawings of technical nature which must not completely or partially - be distributed nor used nor communicated to others without authorization for competition purposes. Company address, spare parts and service address DELIMON Branch office Arminstraße 15 Am Bockwald 4 D Düsseldorf D Grünhain-Beierfeld Phone : [email protected] Fax : Safety These operating instructions contain fundamental instructions which are to be observed during erection, operation and maintenance. Therefore it is absolutely necessary for the fitter and the competent qualified staff/user to read these operating instructions before installation and start-up. The operating instructions must be available at all times at the place of use of the machine/system. Not only the general safety instructions stated under this main point safety are to be observed, but also the other specific safety instructions stated under the other main points. 2.1 Identification of safety warnings in the operating instructions The safety warnings contained in these operating instructions which, if not observed, may cause dangers to people, are specially marked with general danger symbols safety sign according to DIN 4844-W9, warning about a danger spot, in case of warning about electric voltage with safety sign according to DIN 4844-W8, warning about dangerous electric voltage. In case of safety instructions which, if not observed, may cause damage to the machine and its function, the word ATTENTION is inserted. Instructions that are directly attached to the machine, as for example rotational direction arrow identifications for fluid connections must be observed at all events and maintained in a fully legible condition. Note: There is an increased skid risk in case of spilled/leaked out lubricants. They are to be removed at once properly. Safety sign according to DIN , W28, warning about skid risk. page 2 of 15
3 2. Safety (continuation) 2.2 Personnel qualification and training The operating, maintaining, inspecting and erecting personnel must have the appropriate qualification for such work. Area of responsibility, competence and supervision of the personnel have to be regulated by the user. If the personnel do not have the necessary knowledge, they have to be trained and given instructions. This can be effected, if necessary, by the manufacturer/supplier on behalf of the user of the machine. Furthermore, the user has to make sure that the contents of the operating instructions are fully understood by the personnel. 2.3 Dangers in case of nonobservance of the safety instructions The nonobservance of the safety instructions may result in hazards to persons, to the environment and to the machine. The nonobservance of the safety instructions may lead to the loss of any claims for damages. In detail, the nonobservance may for instance lead to the following hazards: Failure of important functions of the machine/system Failure of prescribed methods for maintenance and repair Hazard to persons by electrical, mechanical and chemical influences Hazard to the environment by the leakage of dangerous substances 2.4 Safety conscious working The safety instructions stated in these operating instructions, the existing national regulations as to the accident preventation as well as possible internal working, operating and safety rules of the user are to be observed. 2.5 Safety instructions for the user/operator If hot or cold machine parts lead to dangers, these parts have to be protected against touch. Protection against touch for moving parts (e. g. coupling) must not be removed when the machine is in operation. Leakages (e. g. from the shaft seal) of hazardous goods to be delivered (e. g. explosive, toxic, hot) are to be removed in such a way that there is no danger to persons and environment. Legal rules are to be observed. Hazards caused by electrical power are to be excluded (for details please refer for instance to the rules of the VDE and the local power supply companies). 2.6 Safety instructions for maintenance, inspection and installation work The user has to take care that all the maintenance, inspection and installation work is executed by authorized and qualified skilled personnel who have informed themselves adequately by thoroughly studying the operating instructions. Basically, work on the machine is only to be carried out during shut-down. It is obligatory to observe the shut-down procedure described in the operating instructions. Pumps or pump aggregates that deliver media being hazardous to health have to be decontaminated. Immediately after completion of the work, all safety and protective equipments have to be reinstalled and/or reactivated. Dangers at the pump FZ Danger of squeezing when closing the reservoir lid! When filling the reservoir while the pump is in operation, do not put your hand into the reservoir. Risk of injury by scraper and agitator. In case of drive by oscillating lever, there is an increased risk of injury in the area of the oscillating lever. During operation, the oscillating lever drive is to be protected against unintended touch by means of appropriate covers. When handling lubricants, avoid pollutions of the environment. For cleaning the outside of the pump use suitable solvent-free cleansing agents. Do not use high-pressure cleaning devices. page 3 of 15
4 2. Safety (continuation) Advice: When working with compressed air, do wear glasses. (DIN 4844-G1 Use breathing mask) Advice: Observe EC-Safety Data Sheet for materials of consumption and additives used and use personal protective equipment. (DIN 4844-G4 Use breathing mask) Before recommissioning, observe the points stated in section initial start-up. 2.7 Unauthorized conversion and manufacture of spare parts Conversion or modifications to the machine are only permitted when agreed with the manufacturer. Original spare parts and accessories authorized by the manufacturer serve to ensure safety. The use of other parts may render the liability for consequential losses null and void. 2.8 Unacceptable modes of operation The operational reliability of the machine supplied is only guaranteed if the machine is used in accordance with its intended purposes as per section 1 - General - of the operating instructions. The limiting values specified in the data sheet must on no account be exceeded. 2.9 Guidelines & standards Guidelines 1. Machines 98/37/EG 2. Low voltage 73/23/EWG 3. EMV 89/336/EWG Standards EN Reference ISO Reference acc. to guideline DIN EN 982, 9.96 (ISO 4413, 8.98 (1.) DIN EN 983, 9.96 (ISO 4414, 8.98) (1.) DIN EN 1050, 1.97 (ISO 14121, 2.99) (1.) DIN EN ISO and 2, 4.04 (1.) DIN EN , (IEC , 5.00) (2.) DIN EN , 2.05 (IEC I , 11.03) (2.) DIN EN , 8.02 (IEC , 1.05) (3.) DIN EN , 8.02 (IEC , 1.05) (3.) DIN EN , 8.02 (IEC , 1.05) (3.) 3.0 Notes on environmental protection and waste disposal In correct operation with lubricants, the components are subject to the special requirements set by environmental legislation. The general requirements for lubricants are specified in the respective safety data sheets. Used lubricants are hazardous forms of waste and therefore require special supervision in the sense of 41 paragraph 1 sentence 1 and paragraph 3 no. 1 of KrW-/AbfG (Closed-Loop Waste Management Act). Used oils must be handled in compliance with AltölV (Waste Oil Ordinance). The devices or components contaminated with lubricant must be disposed of by a certified waste management company. Records of proper waste management must be filed in conformance to NachwV (Ordinance on Waste Recovery and Disposal Records). page 4 of 15
5 GENERAL PRODUCT CHARACTERISTICS Central piston technique Insert for anticlockwise and clockwise rotation Feed volume per outlet up to 720cm 3 /h Lubricants: oil, grease, liquid grease Surface signal grey RAL 7004 A PUMP TYPE FZB B NUMBER OF OUTLETS The pump body comprises a control sleeve to guide the piston and, allocated to each outlet, a setting spindle to set the piston stroke and thus the delivery rate of each outlet (up to 6 outlets) or of two outlets together which are placed one above the other (7 up to 12 outlets). Designation and position of the outlets, order in case of combined outlets. Order of outlets see picture. The outlets 1-6 are arranged in the upper row.outlets being placed one above each other can only be joined in the order shown on picture. Fusions begin at the outlets 1/7 and follow the direction of the arrow. If the total grease volume is delivered via 1 outlet, any outlet can be opened (outlet 1 provided in ourworks). If the deals with 2 outlets each of themdelivering half the total output volume, one outlet each of the upper and lower row can be opened (outlets 1 and 7 provided in our works). C INSPECTION Stage A page 5 of 15
6 D. KINDS OF DRIVE Drive with oscillating lever The assembly group constitutes an extension of the assembly group drive with free shaft end containing those parts being necessary for the oscillating lever drive. The oscillating lever is reciprocated by a suitable component part of the machine to be lubricated via an eccentric, a crank and rod, and at the same time, the worm wheel is always turned regardless of the rotational direction of the driving shaft - in the same direction via the switch mechanism. Drive with oscillating lever page 6 of 15
7 D. KINDS OF DRIVE (continuation) Drive with free shaft end The assembly comprises the gearbox housing with the drive shaft and the worm wheel. The drive shaft is mounted in ball bearings. The plug screw is for filling the casing with oil. The plug screw is removed to facilitate the removal of the shaft with a mandrel. Rotary drive with free shaft end page 7 of 15
8 D. KINDS OF DRIVE (continuation) Drive with reduction gear or with reduction gear and motor The assembly consists of the drive assembly with free shaft end, to which a second worm gear drive is added. Drive with reduction gear page 8 of 15
9 D. KINDS OF DRIVE (continuation) Drive with reduction gear and motor E. POSITION OF DRIVE Position 1 left Position 5 right without page 9 of 15
10 F. RESERVOIR The lid can be hinged upwards. It can be secured against unauthorized opening by a padlock. The tank contains a feed unit consisting of a scraper for scraping the grease from the tank wall and a feed screw for slightly pressurising the grease in the pump inlet chamber. A strainer is fitted in the bottom of the tank to protect the pump inlet chamber against dirt. G. ACCESSORIES Level switch A level switch is available for the indication of the filling level in the reservoir. As sensor serves an ultrasonic sensor. As soon as the min. or max. level allowed has been obtained, a signal is released. With the help of a signal lamp at the reservoir, this signal can be used for the visual warning or for the control of an automatic filling facility. In case of receiving the order, we will attach particular operating instructions to the level switch with the following code: BA_2005_1_GB_76951_6011 Pressure control In case of receiving the order, we will attach particular operating instructions to the pressure control: PB_2005_1_GB_ page 10 of 15
11 3. Application The pump FZ-B is designed as a single-piston pump with max. 2 outlets. It is predominantly intended for multiline - centralized lubrication systems. The pump is usually driven by the flange motor or by the machine to be lubricated via an oscillating lever or a coupling. The pump FZ-B has either one combined single outlet with a maximum delivery of 12 x 0.1 cm 3 or with 2 outlets respectively delivering 6 times the quantity of lubricant. 4. Principle of operation (figures 1 and 2) The top of the worm wheel (1) driven by a worm shaft is provided with 2 drivers with recesses in which a crosspiece (2) engages. In two other grooves of the crosspiece the drivers of the eccentric disk (3) engage and impart a rotary movement to the eccentric disk and the piston (4). The compression spring (5) located between the crosspiece and the eccentric disk presses the eccentric disk upwards. On its top surface the eccentric disk is provided with a cam which, due to its rotary movement, strikes the 6 setting spindles (6) arranged on the circumference of the pump and therefore forces the piston to perform one suction stroke each time. The lubricant is supplied to the pump inlet chamber (S) by a feed unit. The underside of the eccentric disk is provided with 6 cams. Due to the rotary movement the cams on the eccentric disk strike against a pressure cam (7), causing the piston to make a compression stroke each time. The piston has three vertical grooves (N), which terminate in an annular channel (R). On pumps with up to 12 (2 x 6) outlets the piston has two sets of three vertical grooves each terminating in an annular channel. During the suction stroke lubricant is drawn from the inlet chamber (S) into the vertical grooves of the piston and from there delivered into the annular channels (R). During the compression stroke the lubricant is delivered from the annular channel via a vertical groove into the pressure channel (D). In continuous operation the pump can overcome a backpressure of 200 bar. Transient pressures of up to 250 bars are permitted. Safety valves can be installed in the discharge line as protection against overload Fig. 1 Section through the pump Fig. 2 Principle of operation page 11 of 15
12 5. Rotational direction of drive All pumps can be arranged for clockwise or anti-clockwise running, as required, with the same power and without modifications. 6. Specifications Permissible back pressure: bar for a short time: bar Permissible pump piston speed: with running drive:... max. 10 r.p.m. with oscillating drive:... max. 16 r.p.m. Number of oscillating strokes:... max. 300 min. -1 In case that higher speed or less then < 1 is requested and also when distributors ZPA or E 4 are installed downstream, ask manufacturer In case of using the oscillating lever drive, the lever rod should be installed in such a way, that the amplitude of the oscillating lever is same in both directions 1 = 2 = max. 50 o Lever amplitude max. : o Lever amplitude min. : o 7. Start-up Installing and connecting the lubricating pump The pump should be installed and mounted vertically. Connection of the motor to be control box must be carried out in accordance with the circuit diagram (paragraph concerning the direction of drive rotation to be observed). Filling the lubricant tank and piping All piping must be carefully cleaned before descaling and blowing through and filled with clean grease using a grease gun. For initial start-up, the grease tank is first filled up to the strainer with oil and then with grease, because otherwise a longer start-up time is required to allow venting. Before connecting the piping the pump must operate long enough at full capacity to ensure that the grease emerges evenly and without air from each outlet. Next, the piping should be connected (use sealing washers), until air-free grease emerges at the ends of the piping. Once the bearings to be lubricated are also filled with grease, the piping can be connected to the lubricating points. The system can be started after adjustment of the required lubricant quantity. Setting the delivery rate (figure 3) At full capacity, corresponding to 0.1 cm 3 lubricant per discharge and piston stroke, an arrow on the discharge identification points to the number 4 stamped on the head of the setting spindle (2.5). By turning the spindle clockwise the delivery is reduced. Reduction below 1/4 of the max. delivery (setting 1) should be avoided. In case of pumps having 7 to 12 outlets, the delivery rate of two vertically arranged outlets is adjusted by means of an adjusting spindle. The second arrow of the discharge identification points to the outlet bore relating to the setting spindle. By changing the drive speed or the internal gear ratio of the pump or also by changing the altitude of the oscillating lever, the output volume of all outlets and thus the overall output volume is changed. page 12 of 15
13 Figure 3 Pump body FZ-B 8. Maintenance Filling the grease tank As soon as approximately 3/4 of the tank capacity are consumed, the grease tank should be refilled. The grease level should never drop to a level where the feed screw is visible, because air may otherwise penetrate into the piping. During filling, care should be taken to ensure that only clean grease is used and no dirt penetrates into the tank when the cover is opened, because this may result in malfunctioning. Filling via a filling valve and firmly installed pipelines is at all events to be preferred. Changing the number of outlets (figure 3) The pump is supplied with the required number of outlets in accordance with the order. If other operating conditions should arise, i.e. if outlets have to be blanked off or opened, the following procedure should be followed. An outlet is blanked off by connecting the pressure channel to the pump inlet chamber. For this purpose the top discharge channels are joined to the pump inlet chamber by threaded connections. To blank off an upper outlet, the tank is removed and the cap screw M 4 x 6 (2.19) is removed from its threaded hole. When opening a blanked-off outlet, the cap screw should be screwed in, taking care to ensure good tightness by means of the sealing A 4 x 8 (2.18). Generally the associated outlet is either closed by means of a screw plug (2.17) or opened by removing the plug. If it deals with of pumps having two vertically arranged outlets, and the lower outlet shall also be shut down, you have to remove the setting spindle (2.5), the ball (2.6) and the compression spring (2.7). Before taking out the spindle, unscrew the shank screw (2.9). After this, insert the plug (2.20) in the bore of the setting spindle. For a later installation of the setting spindle, successively insert after having unscrewed the shank screw (2.9) with sealing ring (2.8) the ball and the compression spring. The locating screw brings spring and ball into the correct position as far as the shank meshes analogously with the spiral groove of the setting spindle on the occasion of the screwing-in process which now follows. Advantageously, you should use a new sealing ring and lubricate both ball and spring prior to inserting them. When two outlets, which are arranged one upon the other, are shut down for a short time, the setting spindle is to be set to 0, and the outlets must not be closed. Use plastic plugs instead of screw plugs (2.17) to allow accidentally occurring delivery rates to escape and to thus avoid overpressure. ATTENTION! If the number of outlets is modified improperly, damage to the pump cannot be avoided. page 13 of 15
14 8. Maintenance (continuation) Removal of the drive shaft (see figure) After removing the spring washer (3.11) and the cap, the circlip (3.13) should be removed. After loosening the plug (3.20) the drive shaft (3.12) including the roller bearings (3.17) and the sleeve (3.16) can be driven out using a copper dowel and a hammer. Gearboxes: The gearboxes are filled with lubricant type grease, Gearmaster LX00 (Messrs. Lubritech) or something comparable by the manufacturer. The filling should only be renewed when the gearbox is dismantled and cleaned. Filling plugs: Main gearbox 3.9 Reduction gear Plates Name plate 110 x 60 mm ( ) Type plate 110 x 60 mm ( ) page 14 of 15
15 Manufacturer s declaration This manufacturer s declaration as to the fulfilment of the requirements according to the EC machine guideline 98/37/EG is only valid in connection with the installation/operating instructions and the relating data sheet, both being valid for the product. We, Company Address Telephone DELIMON GmbH Arminstraße Düsseldorf hereby declare on our sole responsibility that all products supplied by us and being relevant to guidelines and which this declaration refers to, conform to the mentioned standards and that they, if necessary, were released by a competent authority. Applied, harmonized standards: See valid installation/operating instructions with relating data sheet We declare that this consignment comprises an incomplete machine and that the commissioning of the same remains prohibited until it has been determined that the machine into which the machine in question shall be installed, complies with the above mentioned regulations. January 12, 2005 Datum ppa. Doris Pearce Plant Manager ppa. Andreas Wons Direktor Entwicklung & Konstruktion DELIMON GmbH Niederlassung Amtsgericht Düsseldorf Commerzbank AG, Düsseldorf Arminstraße 15 Am Bockwald 4 HRB Konto , BLZ Düsseldorf Grünhain-Beierfeld Geschäftsführer IBAN: DE Deutschland Deutschland Dipl.-Ing. Andreas Buchberger BIC: COBADEFFXXX Telefon: [email protected] Ust.-IdNr.:DE Telefax: Steuer-Nr.:133/5814/0866
Operating instructions Pump FZ-A
Operating instructions Pump FZ-A INDEX Page 1. General... 2 2. Safety... 2 4 A Pump type... 5 B Number of outlets... 5 C Inspection... 5 D Kinds of drive... 6 9 E Position of drive... 9 F Reservoir...
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
Operating Instructions Hand pallet trucks HU Profi. Issue 08.2000
Operating Instructions Hand pallet trucks HU Profi Issue 08.2000 Index 1 Introduction 1.1 Product description 1.2 General information on service and maintenance 1.3 Spare parts 1.4 Dimensions 2 Correct
FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions
FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles
PART 2 FORKLIFT HYDRAULIC SYSTEM
PART 2 FORKLIFT HYDRAULIC SYSTEM Chapter 1 Description and Operation Component Locations & Circuit Layouts 1 Hydraulic Pump 11 Control Valve 14 Valve Section Oil Flows 15 Anti-Cavitation Valve 22 Velocity
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12
BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with
BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap
1263050/6 IM-P126-07 ST Issue 6 BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l
BRANO a.s, 747 41 Hradec nad Moravicí Czech Republic tel.:+420/ 553 632 316, 553 632 303 fax:+420/ 553 632 407, 553 632 151 http://www.brano.eu [email protected] INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION
Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.
Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1
This instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
HYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
Front brakes (FN- 3), servicing
j a t Front brakes (FN- 3), servicing 46-1 Front brakes, servicing Note: Install complete repair kit. After replacing brake pads and before moving vehicle, depress brake pedal several times firmly to properly
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES
GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
Operating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Operating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
ALMATEC Series CX CX 10 CX 130
ALMATEC Series CX CX 10 CX 130 Operating and Installation Instructions ought to be studied before installing the pump The ALMATEC Maschinenbau GmbH is certified as a modern, quality-orientated enterprise
Operating Instructions Parts List Manual Scissor Lift Pallet Truck
Operating Instructions Parts List Manual Scissor Lift Pallet Truck Note: Operator MUST read and understand this operating instructions before use this Hand Scissor Lift. Thank you for using this hand scissors
SINGLE STAGE INLINE FIRE PUMP
MODEL 383 SINGLE STAGE INLINE FIRE PUMP INSTRUCTION AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains
ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions
4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear
DIAMOND Gear Company, LTD. an ERIKS Company Installation, Maintenance, & Operation Manual Declutchable Worm Gear 2016 DECLUTCHABLE WORM GEAR INSTRUCTIONS This is an instructional manual which provides
Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ 100-200
Translation of the original manual Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ 100-200 Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains
Duplex Filters 40 FLDK 0008(C)-0120(C)
Industrial Filters Accumulators Duplex Filters 40 FLDK 0008(C)-0120(C) Filters for inline installation for continuous operating Ball valve change over Optimised flow characteristics by 3D computer aided
INSTRUCTION MANUAL (WINDOW WIPER)
INSTRUCTION MANUAL (WINDOW WIPER) SUBJECT CONTENTS PAGE 1. GENERAL 2 2. CONTRUCTION 2 2-1. STRAIGHT LINE TYPE WINDOW WIPER 2 2-2. CONTROL BOX 2 2-3. SPARE PARTS 2 3. MECHANISM AND OPERATION 2 3-1. STRAIGHT
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification
OWNER S MANUAL Model MH1230 Important Safety Instructions Assembly Instructions Parts and Hardware Identification Pallet Jack CAUTION: Read, understand and follow ALL instructions before using this product
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
M A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
Vertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
TECHNICAL SERVICE MANUAL
TECHNICAL SERVICE MANUAL HEAVY-DUTY PUMPS SERIES 4195 AND 495 SIZES GG - AL SECTION TSM 144 PAGE 1 of 10 ISSUE D CONTENTS Introduction....................... 1 Safety Information.................... 2
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors
Char-Lynn Spool Valve Hydraulic Motors Repair Information W Series Geroler Motors with Parking Brake 004 Nut Key Ring, Retaining Bearing Ring, Retaining Ring, Retaining Washer (Thick), Pressure Washer,
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
Installation instruction
1/5 ATTENTION! Mounting and dismounting of a shrink disc must be restricted to qualified personnel. Incorrect handling may cause injury to persons and damage to machines! At work, with heavy parts and
Machine needle shut-off nozzle type-a
Machine needle shut-off nozzle type-a spring operated Applications: Thermoplastics (not applicable for PVC) Shut-off mechanism: Operated with one axial high performance spring Index of contents Chapter
System Saver 318 Air Compressor for Mack E-Tech and ASET Engines
Maintenance Manual 31 System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Revised 08-05 NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair
KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
MANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water
1 Foreword 1.1 Thank you for choosing one of the range of AEON's BS standard valves. For safety purposes, the user shall read this instruction to fully understand the operation of the product. 2 AEON Design
MODEL T200-F18 MODEL T125-F18 Finish Nailers
P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL
1.8 CRANKSHAFT OIL SEALS
SERIES 60 SERVICE MANUAL 1.8 CRANKSHAFT OIL SEALS An oil seal is fitted between each end of the crankshaft and the bores of the flywheel housing and gear case cover to retain the lubricating oil in the
Pressure regulating valve with modulating kit, type DRV
Operation Installation and Maintenance Instructions Pressure regulating valve with modulating kit, type DRV hp-technik GmbH Industriepumpen-Förderaggregate und Anlagenbau Gablonzer Straße 21 D-76185 Karlsruhe
10 TON HYDRAULIC PRESS
10 TON HYDRAULIC PRESS Model Nos. CSA10F and CSA10B OPERATING & MAINTENANCE INSTRUCTIONS 0200 SPARE PARTS and SERVICING Please contact your nearest dealer, or CLARKE International, on one of the following
Maintenance and Service Instruction
Screw pumps E4 Maintenance and Service Instruction E4 1 IMO AB This instruction is valid for all E4 pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service
MB-Accumulator Operator's Manual
Mathias Bäuerle GmbH Gewerbehallestraße 7-11 D-78112 St.Georgen Telefon (07724) 882-0 Telefax (07724) 882-111 Internet: http://www.mbfold.de E-mail: [email protected] MB-Accumulator Operator's Manual CONTENTS
EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual. B bestflangespreader
EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual B bestflangespreader com INDEX THE EQUALIZER RANGE OF MECHANICAL & HYDRAULIC SPREADING
INSTALLATION, OPERATION & MAINTENANCE MANUAL
INSTALLATION, OPERATION & MAINTENANCE MANUAL Flanged Disk Check Valve with Strainer Ref. GENEBRE: 2450 2451 2452 1 INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE MANUAL 1. Spare parts... 3 1.1
Operataing Manual. Single stage radial Fan. Model MKV/TKV
01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch
BoWex SD, SD1 and SD2 Operating-/Assembly Instructions
D-807 Rheine 0111 E 1 curved-tooth gear couplings are flexible shaft connections. They are able to compensate for shaft displacement caused by, as an example, inaccuracies in production, heat expansion,
Fuel Injection Pump, Rotary (005-014)
Fuel Injection Pump, Rotary View Related Topic Page 1 of 30 Fuel Injection Pump, Rotary (005-014) Table of Contents Summary General Information Preparatory Steps Remove Front Gear Train Rear Gear Train
HYDRAULIC TABLE CART 500-LB.
HYDRAULIC TABLE CART 500-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic
Overflow valve with thread connection
Operation Installation and Maintenance Instructions Overflow valve with thread connection hp-technik GmbH Industriepumpen-Förderaggregate und Anlagenbau Gablonzer Straße 21 D-76185 Karlsruhe Germany Tel.:
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification
CG-1171-20 PTFE Diaphragm Liquid Transfer Pump
3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal
MP-4V Heavy Duty Riveter / 39048
MP-4V Heavy Duty Riveter / 39048 This newly designed heavy-duty air/hydraulic riveter is ergonomically designed with the professional in mind. The light weight 3.7 lbs. well balanced MP-4V includes a Vacuum
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
REPAIR INSTRUCTIONS UNDER BODY CYLINDER (UM, UL)
Table of contents 1. Introduction... 3 1.1. Scope of use... 3 1.2. General remarks... 3 1.3. Contact Hyva... 3 1.4. Precautions... 4 1.5. Spare parts... 4 1.5.1. Prior to use... 4 1.6. Recycling and Reuse
1 TON FOLDING CRANE CFC1000
1 TON FOLDING CRANE CFC1000 OPERATION &MAINTENANCE INSTRUCTIONS 0401 SPECIFICATIONS MAXIMUM SAFE WORKING LOADS (kg) 1 2 3 4 1000 750 500 250 MAXIMUM LIFT HEIGHT - 1920mm HYDRAULIC RAM OIL CAPACITY - 450CC
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)
1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8
Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)
Rear Wheel/Brake/Suspension 13. Rear Wheel/Brake/Suspension Service Information 13-1 Troubleshooting 13-2 Rear Wheel 13-3 Rear Cushion 13-4 Rear Swing Arm 13-7 Service Information General Safety If the
Alfra Rotabest 100 Metal Core Drilling Machine. Operation Manual
Alfra Rotabest 100 Metal Core Drilling Machine Operation Manual 06/2005 1. Technical Data Prod. No.: 18630 Name : Rotabest 100 Input: Load rpm: 1800 Watt 110/175/245/385 rpm Tool Holder : MT 3 Coolant
Instructions and precautions. Fork Height. Visit our website at: http://www.harborfreight.com
Pallet Jack Item 68760 / 68761 Instructions and precautions Specifications Capacity Control Lever Fork Height Fork Length Fork Width Maximum Minimum Width over Forks Steering Wheel Dia. 2-1/2 Ton (5,000
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
VS4760.V2. Instructions for: Diesel Engine Setting/Locking Tool Kit Renault dci Engines. Model No: 1. SAFETY INSTRUCTIONS
Instructions for: Diesel Engine Setting/Locking Tool Kit Renault dci Engines Model No: VS4760.V2 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according