1 Waterbath WNE 7-45 WPE 45 Oilbath ONE 7-45 Operating Instructions page 1
2 page 2
3 1 General notes and safety notes Transport Technical data Material quality Electrical equipment Note on EMC (electromagnetic compatibility) Brief technical description Standard equipment Installation Initial start-up Installation - waterbaths Installation - oilbaths Bath construction and operation Controls and indications Switching on Setting the parameters Temperature setpoint Delayed switch-on Hold time of the setpoint temperature Setpoint-dependent waiting time Circulating pump (WPE 45 only) Temperature monitor Level monitor Setup menu Calibration Selection of temperature monitor (waterbaths only) Programming example of a programme sequence Monitoring the programme sequence Temperature monitor and protection devices Mechanical temperature monitor: temperature limiter Electronic temperature monitor Adjustable temperature monitor (TWW) Protection Class 3.1 to DIN Adjustable temperature limiter (TWB) Protection Class 2 to DIN Monitor relay Use of the cover (special equipment) Level control (special equipment) Cooling system (special equipment) Cleaning and maintenance Check list for fault rectification Action on supply failure Glossary CE Conformity of Declaration Address and customer service Index...26 page 3
4 1 General notes and safety notes You have purchased a technically fully proven product which has been produced in Germany with the use of high-grade materials and the application of the latest manufacturing techniques; it has been factory tested for many hours. In addition we guarantee the supply of spare parts over 10 years. Observation of the Operating Instructions is necessary for faultless operation and for any possible claims under warranty. If these Instructions are disregarded, all claims under warranty, guarantee and indemnification are excluded. This mark on the product means: Note Operating Instructions Warning bath hot when operating The right to technical modifications is reserved. Dimensional details are not binding. 1.1 Transport Always use gloves! If the units W../O.. 22 to 45 have to be carried, at least 2 persons are required. Place the bath accurately horizontal and not on an inflammable support. page 4
5 2 Technical data Model Volume [liter] Usable bath length A [mm] Usable bath width B [mm] Usable bath depth C [mm] Housing length D [mm] Housing width E [mm] Housing height (with flat cover) F [mm] Housing height (with gable cover) G [mm] Weight [kg] Current consume [A] 5,2 5,2 7,8 8,7 10,4 12,2 Power [W] Ambient conditions Ambient temperature 5-40 rh max. 80% (no condensation) Overvoltage Category: II Contamination degree: 2 Setting temperature range 10ºC to 95ºC on waterbaths with activation of the boiling mode to 100, see section ºC to 200ºC on oilbaths Setting accuracy: 0,1 Indication accuracy 0,1 Working temperature range From 5ºC above ambient temperature on waterand oilbaths or 15 above ambient temperature on waterbaths with circulating pump to nominal temperature = maximum temperature (see rating plate) page 5
6 2.1 Material quality Memmert is using stainless steel (Mat.Ref ) for the external casing as well as for the interior, an outstanding material because of its high stability, optimum hygienic features and corrosion resistance against many (not all!) chemical combinations (Attention e.g. at chlorine combinations!). The load has to be tested for its chemical compatibility with the materials mentioned above. A material-compatibility table covering all these materials can be requested from MEMMERT. WARNING! Always pull out the supply plug before opening the bath cover! 2.2 Electrical equipment Operating voltage see rating label 50/60 Hz, WPE 45: 50Hz Protection Class 1, i.e. operating isolation with ground connection to EN Protection IP20 to DIN EN Interference suppression to EN55011 Class B Bath protected by a fuse 250V/15A fast blow Controller protected by a 80 ma fuse (200 ma on 115 V) When connecting a MEMMERT bath to the electrical supply you have to observe any local regulations which apply (e.g. in Germany DIN VDE 0100 with FI protection circuit) 2.3 Note on EMC (electromagnetic compatibility) This product is intended to operate on a supply network with a system impedance Z max at the transfer point (building connection) of Ohm max. The user has to ensure that the product is only operated on an electrical supply network which meets these requirements. If necessary, details of the system impedance can be obtained from the local electricity supply authority. Note: Any work which involves opening up the bath must only be carried out by a properly qualified electrician! 2.4 Brief technical description MEMMERT-water and oilbaths are electrically heated and electronically controlled. The temperature of the thermostating liquid is continuously controlled by a microprocessor-controller with pulse package control. Electronic microprocessor-pid-controller with continuous power matching and autodiagnostic system with fault indicator (see section 12), integral timer for digital programme time selection. The temperature is measured using a Pt100 temperature sensor (4-wire circuit). The accuracy is as follows: WNE ONE Setting accuracy 0,1ºC 0,1ºC Temperature fluctuation ±0,1ºC ±0,2ºC The components of temperature control are controlled by integrated malfunction-recognition. The heaters are installed outside - therefore no problems through dirt or limeresidue. page 6
7 2.5 Standard equipment Electronic fuzzy-supported PID process controller with delayed programme start and programmable hold time. The controller has permanent power matchinig and an autodiagnostic system for rapid fault finding Recessing push/turn control for simple operation of bath Visual alarm indication Mechanical temperature limiter (TB Class 1) Monitor relay to switch off heating in case of fault Boiling mode for temperatures above 95 Setpoint-dependent waiting time Digital overtemperature monitor (on waterbaths choice between TWB Class 2 or TWW Class 3.1, on oilbaths TWB Class 2) Additional digital display of monitoring temperature Two separate, stainless-steel Pt100 temperature sensors (Mat.Ref ) Class A in 4-wire circuit for control and monitoring Built-in sounder as alarm on overlimit, as audible signal at programme end, and to acknowledge input (key click) Warning at low liquid level Convenient calibration directly on the controller at one freely selected temperature Manually switched circulating pump, also pump switch-off at programme end (WPE 45 only) Special equipment (to be ordered separately as accessory): flat cover with concentric ring sets, gable cover to drain condensate, cooling device, various racks for test tubes, bottles etc. 3 Installation min. 750mm space for air circulation min. 80mm space for air circulation min. 80mm The unit must be placed on a horizontal, non-flammable surface which cannot tilt. The vent openings in the left and back side must remain unobstructed. Minimum wall spacing on all sides is 80 mm. The minimum spacing from the top of the bath to the next ceiling (rack, etc.) is 750 mm. page 7
8 3.1 Initial start-up When the bath is started up for the first time, it should be supervised continuously until steady conditions have been reached. 3.2 Installation - waterbaths Mains connection Filling The mains connection cable must be placed away from any hot surface. max water level min water level drain valve In order to garant the high quality of the stainless steel it is recommended by the steel producer to fill the waterbath with deionised water. IMPORTANT! The water level in the bath must be between the two markings at the right side of the tub! Waterbaths can be fitted with a level control system (see section 9). Draining The tank can be drained through the drain valve. The thermostating fluid must be cooled to room temperature before draining. Drain the fluid either directly into an appropriate container or connect an appropriate hose to the drain valve. NOTE: Polluted fluids may not be drained directly into the public wastewater system. If the thermostating fluid is polluted, please make sure that it will be properly filtered or dumped according to the applicable regulations. Operation with non-flammable thermostating liquids only! page 8
9 3.3 Installation - oilbaths Mains connection The mains connection cable must be placed away from any hot surface. Filling max water level min water level drain valve IMPORTANT! The liquid level in the bath must be between the two markings at the right side of the tub! The spacing between top edge of oilbath and liquid level must be at least 30 mm as the oil expands strongly on heating. Draining The tank can be drained through the drain valve. The thermostating fluid must be cooled to room temperature before draining. Drain the fluid either directly into an appropriate container or connect an appropriate hose to the drain valve. NOTE: Polluted fluids and oils may not be drained into the public wastewater system. Please make sure, that the oil will be properlydumped according to the applicable regulations. For safety reasons the flash point of the oil must be at 300ºC or higher. The manufacturer of the oil may also have special regulations for oilchanging intervals due to pollution oraging of the oil which have to be observed. In case of fire never extinguish with water. Use a suitable damping-down medium (e.g. fire blanket)! An overheated bath must never be refilled or topped up!! Warning - bath hot when operating page 9
10 4 Bath construction and operation relatively largest heat loss (since furthest away from the heated ribs) minimum heat loss (since very close to the heated ribs) bath Insulation heating elements The heating positioned on three sides around the tank ensures a natural water circulation of the liquid inside, thus securing an optimal uniform temperature distribution. 4.1 Controls and indications time-symbol delay-symbol (delayed switch-on) hold-symbol (hold time) alarm-symbol temperature display heater-symbol level-symbol pump-symbol SET key push/turn control monitor temperature indication page 10
11 4.2 Switching on The bath is switched on by pressing the push/turn control and can be operated in connection with the SET-key. Bath switched off: The push/turn control is pushed in and protected against damage. 4.3 Setting the parameters A parameter can be selected by rotating the push/turn control; all other parameters are then dimmed. The selected parameter flashes brightly and can now be altered with the push/turn control while holding down the SET key (protection against unintentional alteration). If the push/turn control is rotated quickly the setpoint is altered in large steps; with slow operation it is altered in single steps. After the SET key has been released the newly set value is stored. Further rotation of the push/turn control selects the next parameter. Rotation of the push/turn control selects the following parameters (in the order indicated), to be altered as described above: Temperature setpoint Delayed switch-on Hold time of the setpoint temperature Setpoint-dependent waiting time Circulating pump (WPE 45 only) Temperature monitor page 11
12 4.3.1 Temperature setpoint 90 The bath starts to heat up immediately to the set temperature. t Adjustment range: waterbaths: 10 to 95 or ca. 100 with activation of the boiling mode oilbaths: 10 to 200 Setting and indication accuracy: water-/oilbaths: 0.1 Rotate the push/turn control until the symbol flashes. The setpoint temperature can then be selected with the SET key depressed, as described in Section 4.3. After releasing the SET key the display briefly flashes the setpoint. The display then changes to the actual temperature and the controller starts to control to the selected setpoint temperature. During heating the Waterbaths only: symbol flashes in proportion to the actual heater power. In order to reach water temperatures above 95 (boiling point), waterbaths are provided with the boiling mode. If this is selected, the heating is switched on permanently. Activating the boiling mode by rotating the push/turn control beyond the maximum value until the display shows CCC The setting boiling mode is not stored permanently. After the bath is switched off and on again, the controller shows again the previously selected setpoint Delayed switch-on 90 delay 12h The bath starts to heat up to the previously selected temperature only after the time of the switch-on delay has elapsed. t Adjustment range: 1 min bis 999 hrs Setting accuracy: <100 hrs: 1 min 100 hrs: 1 hr Indication accuracy: <10 hrs: 1 min 10 hrs: 1 hr Rotate the push/turn control until the (delay) and the symbol flashes. The duration of the delayed switch-on can then be set with the SET key depressed as described in Section 4.3. After the SET key has been released the bath briefly flashes the setting of the switch-on delay. The switch-on delay is then activated and the display alternates between the actual temperature and the running time of the switch-on delay. The time is shown with a negative sign and runs down. In this way it is possible to determine at any time how much longer the bath waits until it begins to heat up. If no delayed switch-on is required, it can be de-activated by the setting OFF. page 12
13 4.3.3 Hold time of the setpoint temperature 90 hold 6h The bath switches off the heating after the end of the selected hold time. In this case the hold time includes the heatingup time.. t Adjustment range: 1 min bis 999 hrs Setting accuracy: <100 hrs: 1 min 100 hrs: 1 hr Indication accuracy: <10 hrs: 1 min 10 hrs: 1 hr Rotate the push/turn control until the (hold) and the symbol flashes. The duration of the hold time can then be selected with the SET key depressed, as described in Section 4.3. After the SET key has been released the bath briefly flashes the hold time setting. If no hold time has been programmed, the hold time is activated immediately and the display alternates between the actual temperature and the running time of the hold time. As with switch-on delay, the residual time is shown with a negative sign and runs down. If no hold time is required, it can be de-activated by the setting OFF Setpoint-dependent waiting time 90 hold 6h t The bath switches off the heating after the selected hold time has elapsed. The hold time begins only when the setpoint temperature has been reached. Setting: ON or OFF Rotate the push/turn control until flashes. With the SET key depressed, the setpoint-dependent waiting time can be activated or de-activated. page 13
14 4.3.5 Circulating pump (WPE 45 only) apertures to circulating pump pipe circulating pump waterbath WPE 45 (view from above) Operation of a circulating pump can improve the temperature distribution inside the waterbath. The pump draws water from the centre of the bath and distributes it through the pipes in the front and back of the bath. The continuous water circulation avoids larger temperature differences. At a water temperature of e.g. 90 the temperature difference in the entire bath is less than Note: If the boiling mode CCC has been activated, circulating pump operation is not possible! Setting: ON or OFF Rotate the push/turn control until the symbol flashes. With the SET key depressed the circulating pump can then be switched on and off. page 14
15 4.3.6 Temperature monitor monitor temperature setpoint temperature (see also sections and 7) t Adjustment range: up to 10 above nominal temperature Setting and indication accuracy: <100: : 1 Rotate the push/turn control until the monitor temperature display flashes. The monitor temperature can then be adjusted with the SET key depressed, as described in section 4.3. While the SET key is depressed, the top display shows for information the previously selected setpoint temperature. It is important to ensure that the monitor temperature is always set sufficiently high above the maximum working temperature Level monitor When the liquid level has fallen so far that the upper of the two Pt100 temperature sensors is above the bath liquid, the different temperatures inside and outside the bath liquid cause the symbol to flash, the sounder operates, and the heating is switched off for safety reasons. On topping up the liquid, ensure that the liquid level is between the two level marks on the right inside the bath. (see also Sections 3.2 and 3.3) The bath is again ready for operation after switching it off and on or after pressing the SET key Setup menu The setup menu provides additionally for a single-point calibration and the choice of temperature monitor. To get to the setup menu the SET key has to be depressed while the bath is switched on. After switching on, the display shows the version of the controller software. page 15
16 Calibration Customer calibration of the bath on the controller using a self-selected calibration temperature. A positive or negative calibration difference against it can be set. General calibration instructions: 1. Set the required calibration temperature and set the calibration difference to 0.0 (see below set calibration temperature and set calibration difference ). 2. Measure the deviation from the selected calibration temperature under steady conditions, using a reference instrument. 3. Set the calibration difference. If the measured reference temperature is lower than the indicated value, the calibration difference has to be set with a negative sign. 4. Carry out a check measurement using the reference meter. Example: Temperature difference between controller display (e.g. 70.0) and bath liquid (e.g. 69,0) has to be corrected. 1. Set calibration temperature to 70.0 and set calibration difference to Using a calibrated reference instrument, the measured temperature is 69.0 at a setpoint temperature of Set calibration difference to After the bath has settled down the reference instrument should read calibration difference -1 corrected temperature measurement calibration temperature 70 factory temperature measurement Adjustment range: calibration temperature: waterbaths: 10 to 95 oilbaths: 20 to 200 Adjustment range: calibration difference: water-/oilbaths: -5.0 to [] Set calibration temperature: Rotate the push/turn control until flashes. The calibration temperature can then be set with the SET key depressed as described in section 4.3. Set calibration difference: Rotate the push/turn control until flashes. The calibration difference can then be set with the SET key depressed as described in section 4.3. Note: Setting the calibration difference to 0.0 restores the factory calibration! page 16
17 Selection of temperature monitor (waterbaths only) monitor temperature setpoint temperature Class 2 Class 3.1 monitor temperature setpoint temperature Setting: 2 or 3.1 t Rotate the push/turn control until flashes. With the SET key depressed it is possibile to select the temperature monitor as adjustable temperature limiter (TWB) Protection Class 2 to DIN 12880, or as adjustable temperature monitor (TWW) Protection Class 3.1 (see also sections and 7) t 5 Programming example of a programme sequence 1. Setpoint temperature setting Rotate the push/turn control until the symbol flashes. With the SET key depressed, use the push/turn control to set the temperature setpoint to f.ex Delayed switch-on setting Rotate the push/turn control until the (delay) and the symbol flashes. With the SET key depressed, use the push/turn control to set the time f.ex Hold time setting Rotate the push/turn control until the (hold) and the symbol flashes. With the SET key depressed, use the push/turn control to set the time f.ex Setpoint-dependent waiting time setting Rotate the push/turn control until the push/turn control to set on. 5. Switch on the circulating pump (WPE 45 only) flashes. With the SET key depressed, use Rotate the push/turn control until the symbol flashes. With the SET key depressed, use the push/turn control to set on. 6. Monitor temperature setting Rotate the push/turn control until the monitor temperature display flashes. With the SET key depressed, use the push/turn control to set the monitor temperature to f.ex page 17
18 6 Monitoring the programme sequence 90 During the delayed switch-on the symbol flashes and the display alternates between residual time and actual temperature delay 6h hold 4h Bath does not heat up t 90 delay 6h hold 4h Bath heats up to setpoint temperature t SP activated: After the end of the delayed switch-on the symbol goes dark and the bath heats up to the selected setpoint temperature. The display alternates between actual temperature and SP until the setpoint temperature is reached. Heating is indicated by the symbol. 90 delay 6h hold 4h Bath holds setpoint temperature t SP is de-activated or after the setpoint temperature has been reached: During the hold time the symbol flashes and the display alternates between the residual time and the actual temperature. 90 After the hold time has elapsed the symbol goes dark, the heating is switched off, and the display alternates between the actual temperature and END. delay 6h hold 4h Heating is switched off t page 18
19 7 Temperature monitor and protection devices The monitor temperature is measured with a separate Pt100 temperature sensor inside the chamber. The monitor unit provides protection for the bath load as well as protection for bath and its surroundings. The bath is provided with duplicate overtemperature protection (mechanical / electronic) according to DIN Mechanical temperature monitor: temperature limiter All water- and oilbaths are fitted with a mechanical temperature limiter (TB) Protection Class 1 to DIN If the electronic monitor system should fail during operation and the fixed factory-set maximum temperature is exceeded by approx. 30 the temperature limiter switches off the heating permanently as a final protective measure. The symbol lights up continuously as fault indication. In addition to its function as overtemperature protection the TB also operates as low-level protection, i.e. the heating is switched off permanently if the liquid drops below a certain level. Fault rectification after the TB cut-out has been activated: 1. Switch off the bath and allow it to cool down 2. Rectify the fault (e.g. top up the liquid, replace temperature probe) and where appropriate contact customer service 3. The bath is again ready for operation only after it has cooled down and after the fault has been rectified 7.2 Electronic temperature monitor Monitor temperature Adjustment range: up to 10 max above nominal temperature (for nominal temperature see rating label) Using the push/turn control select the monitor temperature. With the SET key depressed, use the push/turn control to set the monitor temperature. Note: The monitor temperature must always be set sufficiently high above the maximum working temperature. The manually selected monitor temperature of the electronic overtemperature protection is monitored in the case of waterbaths either by an adjustable temperature monitor (TWW) Protection Class 3.1 to DIN or by an adjustable temperature limiter (TWB) Protection Class 2 to DIN 12880, and in oilbaths by an adjustable temperature limiter (TWB). On waterbaths the temperature monitor can be selected in the setup menu (see section or ). For details of temperature monitor and protection class see rating label. page 19
20 7.2.1 Adjustable temperature monitor (TWW) Protection Class 3.1 to DIN If the manually set monitor temperatur is exceeded, the TWW takes over the control of the temperature and starts to control at the monitor temperature. The symbol flashes as warning Adjustable temperature limiter (TWB) Protection Class 2 to DIN If the manually set monitor temperature is exceeded, the TWB switches off the heating permanently and can only be reset by pressing the SET key. The symbol flashes as warning. 7.3 Monitor relay In addition the bath is equipped with an electronic monitor relay. If a fault occurs during operation or if the selected setpoint temperature is exceeded by 10, then the monitor relay continues control of the heating at this temperature in emergency operation.the symbol flashes as warning. Fault rectification after the monitor relay may been activated: Check the controller for error messages (see section 12) and where appropriate contact customer service. Example: With a setpoint temperature of 80, if a fault occurs in the power unit (faulty triac) the bath continues to operate in emergency operation at approx. 90. page 20
21 8 Use of the cover (special equipment) Gable cover The gable cover (may be ordered as already mounted special equipment) should always be closed in order to prevent evaporation of thermostating liquid and to obtain optimal temperature distribution. The gable shape of the cover makes sure that condensed water will not drop down into the loads. Flat cover For positioning of test flasks on top of the bath, a flat cover (special equipment) may be used. The size of the holes in this cover can be adapted to the flasks with ring inserts. The rings may therefore only be inserted or taken off, if the bath is cooled down. Note that during operation the flat cover and the gable cover heat up to the temperature of the thermofluid! 9 Level control (special equipment) 2 different filling levels can be maintained constant if the unit is fitted with a level control system. When using water as thermostating liquid, connect the feed pipe with tubing to the mains water supply. The drain must be connected with tubing to an appropriate container or sink. Make sure, that the tubing cannot be clogged or bended, and that it continually runs downhill. Please note, that the outflowing water may be hot! Supply and drain are indentified by arrows. Use temperature resistant material for the tubing. If the second overflow is not required, it must be closed with a sealing cap. The evaporation loss can be compensated through a slightly open water supply (dripping) and can be monitored through the observation window. The level control system cannot be retrofitted! observation window supply drain drain Warning bath hot when operating page 21
22 10 Cooling system (special equipment) If the waterbath is fitted with a cooling device for quicker cooling of the bath liquid, the water supply has to be connected by a hose f.ex. to a cold water supply line. The discharge has to be lead into a drain. water supply (Use temperature resistant material for the tubing) discharge Please note, that the outflowing water may be hot! The discharge must be connected with tubing to an appropriate container or sink. Make sure, that the tubing cannot be clogged or bended, and that it continually runs downhill. 11 Cleaning and maintenance By regular cleaning of the easy to clean the tank, residues are avoided which at continuous influence can impair the outfit and function of the water-/oilbath. Please use only detergents and antiliming agents appropriate for stainless steel for the cleaning of the tank and the housing (stainless steel detergents usual in the trade)! Water baths only: After cleaning and after draining the water the stainless steel tank must be rinsed thoroughly with clear water and dried carefully! It is important to ensure that no rusting objects come into contact with the stainless steel bath tank or the stainless steel housing. Rust sediments lead to contamination. If rust stains caused by contamination occur on the tank surface, the affected areas must be cleaned and polished immediately. On units with gable cover we recommend that the hinge bolts are oiled from time to time if the bath is used frequently. page 22
23 12 Check list for fault rectification Main switch ON, no indication on the display symbol not alight symbol alight symbol flashes symbol flashes C O N F E - 1 E - 2 E - 3 E - L Main fuse 15A or instrument fuse T80mA 250V~ on circuit board x has blown Controller faulty Electrical supply interrupted Ambient temperature too high Temperature in bath above the selected setpoint temperaturer Temperature protection (TB) has operated Temperature protection (TWW/TWB) has operated Monitoring relay has operated Liquid level too low Error on self test Power module triac faulty Power module faulty Pt100-temperature probe faulty Communication to power unit interrupted In case of a malfunction contact an authorized service station for Memmert equipment or please inform the Memmert service department (see section 16). In case of queries always specify model and serial number (on the rating label) 13 Action on supply failure After a failure of the supply, operation continues with the previously set parameters. 14 Glossary nominal temperature = the maximum adjustable setpoint temperature of the bath. ambient temperature = the continuous temperature of the room in which the bath is set up setpoint temperature dependent on operation = the integrated digital timer for the hold time starts no earlier than the temperature in the bath has reached the setpoint to least 0.5 at 95 nominal temperature resp. 2 at 200 nominal temperature. page 23
24 15 CE Conformity of Declaration EC Declaration of Conformity Manufacturer s name and address: MEMMERT GmbH + Co. KG Äußere Rittersbacher Straße 38 D Schwabach Product: Waterbath / Oilbath Type: WNE / ONE / WPE 45 Sizes: 7 / 10 / 14 / 22 / 29 / 45 Nominal voltage: AC 230 V 50/60 Hz alternative AC 115 V 50/60 Hz The designated product is in conformity with the European EMC-Directive 89/336/EEC including amendments Council Directive of 03 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility. Full compliance with the standards listed below proves the conformity of the designated product with the essential protection requirements of the above-mentioned EC Directive: DIN EN 61326: EN 61326:1997 EN 61326/A1:1998 EN 61326/A2:2001 EN 61326/A2:2003 The designated product is in conformity with the European Low Voltage Directive 73/23/EEC including amendments Council Directive on the approximation of the laws of the Member States relating to Electrical equipment for use within certain voltage limits. Full compliance with the standards listed below proves the conformity of the designated product with the essential protection requirements of the above-mentioned EC Directive: DIN EN (VDE 0411 part 1): EN :2001 DIN EN (VDE 0411 part 2-010): EN :2003 Schwabach, (Legally binding signature of the issuer) This declaration certifies compliance with the above mentioned directives but does not include a property assurance. The safety note given in the product documentation which are part of the supply, must be observed. Modelljahr 2006 D10290 / page 24
25 Standard units are safety-approved and bear the test marks: This product is subject to the Directive 2002/96/EC by the European Parliament and the EU Council of Ministers which concerns Waste Electrical and Electronic Equipment (WEEE). This product has been put on the market after 13 August 2005 in countries which have already incorporated this Directive into National Law. It should not be disposed off as part of domestic refuse. For disposal please contact your dealer or the manufacturer. Products which are infected, infectious or contaminated with health-endangering substances are excluded from return. Please note also all further regulations in this context. 16 Address and customer service MEMMERT GmbH+Co.KG PO Box Schwabach Germany Phone: / Fax:: / [email protected] Internet: Customer service: Phone: / or / [email protected] In case of queries always specify model and serial number (on the rating label) by MEMMERT GmbH+Co.KG page 25
26 17 Index A address 25 alarm symbol 19, 20 ambient conditions 5 ambient temperature 23 autodiagnostic system 6 B bath construction 10 boiling mode 5 boiling mode, activate 12 brief technical description 6 C CAL 16 calibration difference 16 calibration of the temperature 16 calibration temperature 16 CE conformity of declaration 24 check list for fault rectification 23 chemical compatibility 6 circulating pump 14 cleaning 22 controls 10 cooling system 22 cover, flat 21 cover, gable 21, 22 customer service 25 D deionised water 8 delayed switch-on 12 DIFF 16 DIN , 20 disposal 25 draining - oilbaths 9 draining - waterbaths 8 drain hose 21, 22 drain valve 8, 9 E electrical equipment 6 electromagnetic compatibility 6 evaporation loss 21 F fault rectification 23 filling - oilbaths 9 filling - waterbaths 8 flash point of the oil 9 G glossary 23 H heating 10 hinge bolts 22 hold time of the setpoint temperature 13 I indication 10 initial start-up 8 installation 7 installation - oilbaths 9 installation - waterbaths 8 L level control system 8, 21 level monitor 15 liquid level - oilbaths 9 liquid level - waterbaths 8 low-level protection 19 M maintenance 22 Mat.Ref material quality 6 monitor relay 20 monitor temperature, selection 15 monitor unit 19 N nominal temperature 5, 23 P parameter settings 11 polluted fluids 8, 9 programme sequence monitoring 18 programming example 17 Protection Class 1 19 Protection Class 2 20 Protection Class Pt100 temperature sensor 6 R rust deposits 22 S SAFE 17 safety notes 4 setpoint-dependent waiting time 13 setpoint dependent operation 23 setpoint temperature 23 setpoint temperature, selection 12 Setup menu 15 SP 13, 18 standard equipment 7 supply failure 23 switching on the bath 11 T TB 19 technical data 5 temperature diviation 16 temperature fluctuation 6 temperature limiter (TB) 19 temperature limiter (TWB) 20 temperature measurement 6 temperature monitor 15, 19 temperature monitor, selection 17 temperature monitor (TWW) 20 temperature setpoint 23 temperature setpoint, selection 12 thermostating liquid 6, 21 thermostating liquid - oilbaths 9 thermostating liquid - waterbaths 8 transport 4 TWB 20 TWW 20 U uniform temperature distribution 10 W water circulation 10 working temperature range 5 page 26
27 page 27
28 Water-/Oilbath englisch D10333 page 28
Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1
Operating Instuctions Shaking device SV 14 / 22 SV 29 / 45 page 1 General notes, safety notes, notes on electrical equipment and electromagnetic compatibility, as well as notes on maintenance of the unit
WATERBATHS AND OILBATHS
WATERBATHS AND OILBATHS New bath generation, still more accurate through innovative control technology Combined start delay and hold time; on Excellent models setpoint-dependent More security through at
Waterbaths and Oilbaths WNB/WNE/WPE/ONE
Waterbaths and Oilbaths WNB/WNE/WPE/ONE New bath generation, still more accurate through innovative control technology Combined start delay and hold time; on Excellent models setpoint-dependent More security
OPERATING INSTRUCTIONS Humidity Chambers HCP 108 HCP 153 HCP 246
OPERATING INSTRUCTIONS Humidity Chambers HCP 108 HCP 153 HCP 246 HCP page 2 1 General notes and safety notes...5 1.1 Transport...5 2 Installation...6 2.1 Subframe (accessory)...6 2.2 Stackable version
OPERATING INSTRUCTIONS. Vacuum Drying Oven VO 200 VO 400 VO 500. Pump Module PM 200 PM 400 PM 500
OPERATING INSTRUCTIONS Vacuum Drying Oven 200 400 500 Pump Module PM 200 PM 400 PM 500 1. Contents... 2 2 General notes and safety notes... 4 2.1 Safety check... 4 2.2 Transport... 4 3 Installation facilities
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
WB/WBS 3, 4, 5, 7, 8, 11, 14, 30
INSTRUCTION MANUAL FOR WB/WBS 3, 4, 5, 7, 8, 11, 14, 30 WATER BATH PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 [email protected]
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
Operations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
Climate chamber with illumination
KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR
CAUTION! Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR NOTE: read the manual prior to commencement of use. For safety reasons, the pump can only be operated by
B/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
Operating instructions IV / 2007
General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Hot Water Urns. all models. Helpline. v3.0
Hot Water Urns all models Helpline 01384 573999 instructions.indd 1 v3.0 02/06/2014 14:50 IMPORTANT INFORMATION - RETAIN FOR FUTURE USE When using any electrical appliance, basic safety precautions should
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
Manual 20.2.2015 v1 Page 1 of 17. Manual. Laboratory autoclave
Manual 20.2.2015 v1 Page 1 of 17 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
Operating instructions II / 2004
Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)
FLEXIT S4 R S6 R S7 R
94111E-05 2005-10 FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 2.1 Heating
OPERATING INSTRUCTIONS UM 200-800 SM 200-400 ULM/SLM 400-800 06/99
OPERATING INSTRUCTIONS UM 200-800 SM 200-400 ULM/SLM 400-800 06/99 TABLE OF CONTENTS 1 Congratulations on your choice of a MEMMERT Oven! 2 2 Technical data summary 3 2.1 Electrical supply 3 2.2 Installation
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
MP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
Unstirred Water Baths
Unstirred Water Baths JB Academy JB Nova SUB Aqua Pro Operating Manual [email protected] Tel: +44 (0)1763 260811 Detailed operating manual Page 1 If you have any feedback on Grant s products or
Unstirred Water Baths
Unstirred Water Baths JB Academy JB Nova SUB Aqua Pro Operating Manual [email protected] Tel: +44 (0)1763 260811 31394 V3 Detailed operating manual Page 1 If you have any feedback on Grant s products
FT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
Operating instructions for built-in electronic timers with Day and Week programms. Series 884
Operating instructions for built-in electronic timers with Day and Week programms Series 884 Attention: This operating manual is destined for our OEM customers and is intended as a basis for the instruction
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Instruction manual. VWR unstirred water baths
Instruction manual VWR unstirred water baths Introduction VWR laboratory thermostatic baths provide the means to maintain samples at a precise temperature from just above room temperature up to 99 0 C.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Operation Manual. Trash Water Pump - ARTIKEL 50788. Read and follow the operating instructions and safety information before using for the first time.
Operation Manual Trash Water Pump - ARTIKEL 50788 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments,
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: [email protected], Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall