Filters for fixed installations
|
|
|
- Cornelius Gabriel Allison
- 9 years ago
- Views:
Transcription
1 CYCLONE FU MECHANICAL FILTERS The FU are especially intended for filtration of dusts and heavy particles bigger than 5 microns. Centrifugal filtration is used for grinding, sanding, oxycut, all heavy, non explosive particles. Cyclones must be used at their flow rate capacity to ensure an optimal filtration. Pressure losses are between and Pa Cyclone filtration for heavy particles of more than 5µ, has an efficiency of 95 to 98%. It is an efficient and not expensive filtration, but the air won't be recycled in the working area. It is also a pre-filtration for big quantities of dusts before a fine filtration. Cyclone FU200 (500 m³/h) W Cyclone FU315 (1 000 m³/h) W Cyclone FU400 (2 000 m³/h) W Cyclone FU500 (3 000 m³/h) W W Cyclone FU630 ( m³/h) W W Cyclone FU710 (6 300 m³/h) W W Cyclone FU800 (8 200 m³/h) W W Cyclone FU900 ( m³/h) Cyclone FU1100 ( m³/h) Partie corps supérieur Cyclone FU1300 ( m³/h) CYCLOFILTRES CD TheCYCLOFILTERS CD can be used both for welding fume and for grinding or sanding non explosive dusts. They combine cyclone filtration to mechanical filtration through highly efficient cartridges in polyester PFTE membrane H13 class (W3), ensuring emission after filtration lower than 1 mg/m³. The quantity of cartridges used depend on the type of CYCLOFILTER. Thanks to their composition, the operation vacuum rate can be of Pa, and is perfectly adapted to the high vacuum plant applications: - CYCLOFILTER 2CD: 2 cartridges 10 m², filtered flow 2000 m³/h, Ø E/S 160 mm. - CYCLOFILTER 4CD: 4 cartridges 10 m², filtered flow 4000 m³/h, Ø E/S 250 mm. - CYCLOFILTER 6CD: 4 cartridges 10 m², filtered flow 4000 m³/h, Ø E/S 250 mm. A CYCLOFILTER is provided with its electric control board CE including the automatic cleaning sequencer. CYCLOFILTRE 2CD CYCLOFILTRE 4CD CYCLOFILTRE 6CD Cleaning sequencer POLYESTER cartridge membrane PTFE W W W W W Note: This kind of device filters solid non explosive dry particles exclusively. In welding, since pollutants are both solid and gaseous, it must not be used in welding, in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed to comply with the regulations in force. 40
2 MECHANICAL CARTRIDGE FILTERS MECAZUR 35M The wall mechanical filter MECAZUR 35M is a filter intended for fume filtration and dry non explosive particles. It is a versatile filter, for an application with 1 or 2 collection arms in direct mounting or for a mounting in centralised network It is equipped with a filtration cassette with a surface of 35 m² and a metal pre-filter. Maximum suction flow 2400 m³/h. POLYARTICULATED or ECOFLEX suction arms are fixed directly under the filter. Spare pre-filter: W Fine filter: W Note: This kind of device filters solid non explosive dry particles exclusively. It must not be used, in welding in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed to comply with the regulations in force. Use with 1 arm MECAZUR 35M wall version W MECAZUR 35M ground version W Fan to be associated to 1 arm Fan AZUR 2.1 W Fan adapter flange W Use with 2 arm MECAZUR 35M wall version W MECAZUR 35M ground version W Fan to be associated to 2 arm Fan AZUR 4.7 W TRC fan Ø 315 mm W Fan adapter flange W Sectioning board 230 V-3 Ph-50 Hz: for fan AZUR 2.1 W V-3 Ph-50 Hz: for fan AZUR 2.1 W V-3 Ph-50 Hz: for fan AZUR 4.7 W V-3 Ph-50 Hz: for fan AZUR 4.7 W MODULAR MECHANICAL FILTERS MECAFILTER The mechanical filters MODULAR MECAFILTER are intended for fume filtration and dry non explosive particles. They are filters for POLYVALENT filtration of a centralised collector of welding fume or low concentration dusts, with big flows. Filters are equipped with filtration cassette with a unitary surface of 35 m² and metal pre-filters. Maximum suction flow: - MECAFILTER M2: 4000 m³/h - MECAFILTER M3: 6000 m³/h - MECAFILTER M4: 8000 m³/h - MECAFILTER M5: m³/h - MECAFILTER M6: m³/h 2 options complete the filters: A) Activated carbon cell for odours, carbon load 30 kg for each cell. B) Filtration HEPA H12 of 22 m² for each filtration cassette. Note: the 2 options can be combined for a complete filtration: metal pre-filter, fine filter cassette 35 m² for each filter, HEPA H13 filter of 42 m² and activated carbon. M2: 2 pre-filters, 2 fine filters and 2 HEPA filters and/or 2 activated carbon filters. M3: 3 pre-filters, 3 fine filters and 3 HEPA filters and/or 3 activated carbon filters. M4: 4 pre-filters, 4 fine filters and 4 HEPA filters and/or 4 activated carbon filters. M5: 5 pre-filters, 5 fine filters and 5 HEPA filters and/or 5 activated carbon filters. M6: 6 pre-filters, 6 fine filters and 6 HEPA filters and/or 6 activated carbon filters. Note: This kind of device filters solid non explosive dry particles exclusively. It must not be used, in welding in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed to comply with the regulations in force. MECAFILTRE MODULAIRE M2 (70 m²) W MECAFILTRE MODULAIRE M3 (105 m²) W MECAFILTRE MODULAIRE M4 (140 m²) W MECAFILTRE MODULAIRE M5 (175 m²) W MECAFILTRE MODULAIRE M6 (210 m²) W Absolute filter option Filtration HEPA H12 M2 (44 m²) W Filtration HEPA H12 M3 (66 m²) W Filtration HEPA H12 M4 (88 m²) W Filtration HEPA H12 M5 (110 m²) W Filtration HEPA H12 M6 (180 m²) W Activated carbon filtration option Filtration Activated carbon M2 (60 kg) W Filtration Activated carbon M3 (90 kg) W Filtration Activated carbon M4 (120 kg) W Filtration Activated carbon M5 (150 kg) W Filtration Activated carbon M6 (180 kg) W T R C for filter Set of 2 TRC Ø 315 mm for M2 filter W Set of 2 TRC Ø 400 mm for M3 filter W Set of 2 TRC Ø 500 mm for M4 filter W Set of 2 TRC Ø 560 mm for M5 filter W Set of 2 TRC Ø 630 mm for M6 filter W Spare filter Metal pre-filter W Mechanical fine filter 35 m² W HEPA filter H13 42 m² W Cassette loaded with activated carbon W kg bag of activated carbon W
3 FANS FOR MODULAR FILTERS Fan for M2 filter Fan m³/h under Pa D400 A - 4 kw - 230/400 V - 50 Hz TRC fan Ø 400 mm W W Fan for M3 filter Fan m³/h under Pa D400B kw - 230/400 V - 50 Hz TRC fan Ø 400 mm Fan for M4 filter Fan m³/h under Pa D450 A kw - 400/660 V - 50 Hz TRC fan Ø 500 mm Fan for M5 filter Fan m³/h under Pa D450B - 11 kw - 400/660 V - 50 Hz TRC fan Ø 500 mm Fan for M6 filter Fan m³/h under Pa PAS kw - 400/660 V - 50 Hz TRC fan Ø 630 mm W W W W W W Fan control board Depending on the engine power and the need of automation or adjustment: - Sectioning cabin - MASTER BOX ESSENTIAL - EXPERT BOX - Fan control box Le filtre mécanique MECAFILTER 30C est un filtre à cartouche filtrante à décolmatage. Il est destiné à la filtration des fumées et particules sèches abondantes non explosibles. Ce filtre polyvalent convient pour 1 bras de captage. Le filtre est équipé d une cartouche de surface filtrante de 30 m² permettant une utilisation avec un débit d aspiration maximum de 1600 m³/h. Le décolmatage de la cartouche est assuré par le sytème Robotclean. La cartouche filtrante est protégée par un caisson préfiltre métallique externe agissant contre les particules incandescentes pouvant être aspirées. Le MECAFILTER 30C possède un indicateur de saturation de la cartouche filtrante. Suivant le bras choisi ou la potence retenue, on associera le ventilateur FAN 28 ou le fan AZUR 42. (autres ventilateurs en page 32) Le MECAFILTER 30C sera associé au coffret de contrôle MASTER BOX ESSENTIAL. 42
4 MECAFILTER 50M AZUR MECHANICAL FILTER The mechanical filter MECAFILTER 50M AZUR is intended for fume filtration and dry non explosive particles. Its design makes it a versatile filter for a filter with 1 or 2 collection arms PICKFUME or EASYPICKEFUME. Its fine filter, cartridge type, provides a big filtration surface of 50 m², thus allowing the use with a maximum suction flow of m³/h (2 arms at m³/h). The filtration cartridge is protected by an external metal pre-filter hood extracting the incandescent particles. MECAFILTER 50M AZUR bears a saturation indicator of the filtration cartridge. Depending on whether you use 1 or 2 arms, you can associate the FAN 28 fan or the AZUR 42. (other fans in page 32) Note: This kind of device filters solid non explosive dry particles exclusively. It must not be used, in welding in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed to comply with the regulations in force. MECAFILTER 50M AZUR W Fan to be associated to 1 arm Fan FAN V-3 Ph-0.75 kw W Fan FAN V-3 Ph-0.75 kw W Electric protection Sectioning cabin 0.75 kw-230 V W Sectioning cabin 0.75 kw-400 V W Fan to be associated to 1 crane Fan AZUR /400 V-1.5 kw W Hose D 200 mm, length 1.5 m W Electric protection Sectioning cabin 1.5 kw V W Sectioning cabin 1.5 kw V W Metal pre-filter W Filtration cartridge 50 m² W MECAFILTER 30C MECHANICAL FILTER The mechanical filter MECAFILTER 30C is a cleaning filtration cartridge. It is intended for fume filtration and abundant dry non explosive particles. This POLYVALENT filter is adapted for 1 collection arm. The filter is equipped with a filtration surface of 30 m² allowing the use with a maximum suction flow of 1600 m³/h. The cleaning of the cartridge is ensured by the Robotclean system. The filtration cartridge is protected by an external metal pre-filter hood extracting the incandescent particles. MECAFILTER 30M bears a saturation indicator of the filtration cartridge. Depending on the selected arm or crane, you can associate the FAN 28 fan or the AZUR 42. (other fans in page 32) The MECAFILTER 30C will be associated to the control box MASTER BOX ESSENTIAL. NotE: This kind of device filters solid non explosive dry particles exclusively. It must not be used, in welding in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed to comply with the regulations in force. MECAFILTER 30C W Fan to be associated to 1 arm Fan FAN V-3 Ph-0.75 kw Fan FAN V-3 Ph-0.75 kw Fan control and 30C filter Box MASTER BOX ESSENTIAL Thermal safety 230 V-3 Ph Thermal safety 400 V-3 Ph Fan to be associated to 1 crane FanAZUR /400 V-1.5 kw Hose D200 mm, length 1.5 m Fan control and 30C filter Box MASTER BOX ESSENTIAL Thermal safety 230 V-3 Ph Thermal safety 400 V-3 Ph W W W W W W W W W W Automatic commissioning for FAN28 or AZUR42 fans CA/CC current sensor W Light sensor and automatic START STOP lamp for arm. Metal pre-filter Filtration cartridge 30 m² W Completed with W W W
5 ELECTROSTATIC FIXED FILTERS SFE-SFM 25/50/75 The fixes units of electrostatic filtration SFE ALW have been specially designed for gas treatment of carbon steel welding and of fatty fumes. Filtration is done in 4 steps: aluminium pre-filtration (complement 1), ionising cell (10kV), collection cell (5kV) and a synthetic post filter G3 (complement 2). A saturation alarm is included in all SFE ALW filters. All these filtration phases are washable. Filtration capacity: SFE 25: m³/h (2 arms), m³/h in recycling. SFE 50: m³/h (4 to 5 arms), m³/h in recycling. SFE 75: m³/h (6 to 7 arms), m³/h in recycling. The SFM ALW are filtration bag filters. They combine an excellent performance with a low air resistance. They are intended for low concentration fume/dusts applications and are particularly adapted as finishing and safety filter for the SFE and ALW filters. Filtration capacity: SFM 25: m³/h, SFM 50: m³/h, SFM 75: m³/h. Note: the inlet/outlet hoppers of the SFE and SFM filters are controlled separately depending on installation and choice of the associated fan. Note: This kind of device filters solid non explosive particles exclusively. It must not be used, during welding in confined atmosphere. It is strongly recommended to connect it to an external release in the building, where it is installed to comply with the regulations in force. SFM filter Filter SFE ALW RIGHT inlet SFE 25 ED SFE 50 ED SFE 75 ED Filter SFE ALW left inlet SFE 25 EG SFE 50 EG SFE 75 EG Complement 1: Pre-filter Aluminium pre-filter G3 (1 for SFE 25, 2 for SFE 50 and 3 for SFE 75) Complement 2: Post-filter Synthetic post-filter G3 (1 for SFE 25, 2 for SFE 50 and 3 for SFE 75) Activated carbon option for odours Activated carbon Post-filter G3 (1 for SFE 25, 2 for SFE 50 and 3 for SFE 75) Remote control option Remote control Filters SFM ALW RIGHT inlet (integrated pre-filter) SFM 25 ED SFM 50 ED SFM 75 ED Filters SFM ALW LEFT inlet (integrated pre-filter) SFM 25 EG SFM 50 EG SFM 75 EG Media Post-filter G3 (1 for SFE 25, 2 for SFE 50 and 3 for SFE 75) Bag filter SFM (1 for SFM 25, 2 for SFM 50 and 3 for SFM 75) W W Sur demande W W Sur demande W W W C W W Sur demande W W Sur demande W W CLEANING FILTER 2D The automatic cleaning compact filter 2CD is equipped of 2 highly efficient filtration cartridges 10 m² in Polyester membrane PTFE (W3) and is adapted for applications of dry non explosive dusts: sanding, grinding, welding, cutting. Adapted for the filtration of 1 or 2 arms (2 x m³/h), of a grinding table x 500 mm, of a downdraft panel x mm. Metal pre-filter integrated into the air inlet, dusts recovery drum in the lower part of the filter. Engine power 3 kw 400 V-3 Ph, providing m³/h under 2500 Pa or 2500 m³/h under Pa. Inlet/outlet diameter = 250 mm. Height mm, Depth 900 mm, Width 900 mm, Weight 240 kg. Control cabinet of the CE filter with remote control 10 m long. Automatic cleaning sequencer of the cartridges with saturation alarm. Filter 2CD Optional items Silencer Ø 250 mm Air regulator filter Metal pre-filter Cartridge 10 m² membrane PFTE (2) W W W W W Note: This kind of device filters solid non explosive particles exclusively. It must not be used, in welding in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed to comply with the regulations in force. 44
6 ESSENTIAL CLEANING FILTER The ESSENTIAL automatic cleaning filters combine a highly efficient filtration quality (filtration cartridges Polyester membrane PTFE W3 - H13) to a high performance centrifugal jet fan, to a solid filter structure made up of epoxy painted galvanised sheets. Thanks to their composition, filters can be placed outside the building without additional protection. The ESSENTIAL filters provide an excellent value and have, at the air inlet, a metal pre-filter against glowing particles of welding/grinding and non-return valves blocking dusts in the filter during OFF LINE cleaning (fan stopped). They are intended for all dry non explosive dusts or fume, in low concentration for dusts recovery drum version, in high concentration for BIG BAG versions and rotary airlock (ER). The ESSENTIAL filters integrate the control of saturation of filtration elements, sound and light control, along with a pre-set threshold cleaning or continuous ON LINE To comply with the machines directive 2006/42/CE in force since 29/12/2009, filters include in their control cabinet, an emergency stop line. The commissioning of the filter can be either manual or controlled by the PROCESS to which it is connected. The inlet on an ESSENTIAL filter is done on the right side or on the front side. If, for a specific mounting, the inlet has to be on left, a symmetrical version will be created upon request. The highly efficient filtration cartridge in polyester membrane PTFE is intended for filtration of dry non explosive dust. Thanks to its surface filtration through the PFTE membrane, it allows high concentration dust filtration with low pressure loss, lower than 30 to 50%, as regards a traditional cartridge. These performances reduce engine power of the fan with equivalent collection efficiency and allow, consequently, a decrease in the CO 2 production. Note: This kind of device filters solid non explosive particles exclusively. It must not be used, in welding in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed, to comply with the regulations in force. ESSENTIAL filters with dusts recovery drum Filter ESSENTIAL 4CD, motor 4 kw m³/h under Pa or m³/h under Pa W cartridges W3 of 10 m², E/S Ø 315 mm Filter ESSENTIAL 4CD RC EASY with remote control 10 m W Filter ESSENTIAL 6CD, motor 5.5 kw m³/h under Pa or m³/h under Pa 6 cartridges W3 of 10 m², E/S Ø 400 mm Filter ESSENTIAL 6CD RC EASY with remote control 10 m Filter ESSENTIAL 8CD, motor 7.5 kw m³/h under Pa or m³/h under Pa 8 cartridges W3 of 10 m², E/S Ø 450 mm Filter ESSENTIAL 8CD RC EASY with remote control 10 m Filter ESSENTIAL 10CD, motor 11 kw m³/h under Pa or m³/h under Pa 10 cartridges W3 of 10 m², E/S Ø 500 mm Filter ESSENTIAL 12CD, motor 15 kw m³/h under Pa or m³/h under Pa 12 cartridges W3 of 10 m², E/S Ø 500 mm Filter ESSENTIAL 16CD, motor 18.5 kw m³/h under Pa or m³/h under Pa 16 cartridges W3 of 10 m², E/S Ø 560 mm W W W W W W W Filters with BIG BAG and rotary airlock (2 for the 16CD) Filter ESSENTIAL 4CD ER (BIG-BAG) E/S Ø 315 mm W Filter ESSENTIAL 6CD ER (BIG-BAG) E/S Ø 400 mm W Filter ESSENTIAL 8CD ER (BIG-BAG) E/S Ø 450 mm W Filter ESSENTIAL 8CD ER RC (remote control 10 m), E/S Ø 450 mm W Filter ESSENTIAL 10CD ER (BIG-BAG) E/S Ø 500 mm W Filter ESSENTIAL 12CD ER (BIG-BAG) E/S Ø 500 mm W Filter ESSENTIAL 16CD ER (BIG-BAG) E/S Ø 560 mm W Metal pre-filter (2 or 4 depending on filter) Cartridge 10 m² membrane PFTE W3 Complement silencer filter outlet Silencer Ø 315 mm Silencer Ø 400 mm Silencer Ø 450 mm Silencer Ø 500 mm Silencer Ø 560 mm W W W W W W W
7 CLEANING FILTER I.C.P. The automatic cleaning filters ICP (INTELLIGENT CONTROL PROCESS) are especially studied to combine great efficiency, low sound level, compactness of the filter and of its fan (compact range). ICP filters are provided with their fan controlled by a frequency converter allowing a flow adjustment (cutting table application) or a variable flow operation (automated multi-sensors network). The installation of a filter outside is done without protective canopy. They are intended for all dry non explosive dusts or fume, in low concentration for dusts recovery drum version, in high concentration for BIG BAG versions and rotary airlock (ER). ICP filters (designed, created and produced in France), are controlled by a frequency converter and electronic pressure sensors. To comply with the machines directive 2006/42/CE in force since 29/12/2009, filters include in their control cabinet, an emergency stop line. The commissioning of the filter can be either manual or controlled by the PROCESS to which it is connected. Emergency stops line, level 2. ICP filters include metal pre-filters in the air inlet and a non-return valve. I.C.P (Intelligent Control Process) cleaning cartridge filters, represent a significant technical development of the filtration optimising permanently the electric power of the fan to its real need, reducing thus the CO² production and your energy consumption while providing a real time control of the efficiency of your process. Highly efficient filtration cartridges in polyester PFTE membrane are W3 class (Hepa H13). Its surface filtration through the PFTE membrane allows high concentration dust filtration with low pressure loss, lower than 30 to 50 %, as regards a traditional cartridge. These performances reduce engine power of the fan with equivalent collection efficiency and allow, consequently, a decrease in the CO².production. Note: This kind of device filters solid non explosive dry particles exclusively. It must not be used during cutting in confined atmosphere. It is strongly recommended to connect it to an external release in the building where it is installed to comply with the regulations in force. ICP compact FILTERS with dusts recovery drum Filters ICP 4, m³/h under Pa or m³/h under Pa, engine power 4 kw - Right inlet version - ES D 315 mm W Left inlet version - ES D 315 mm W Filters ICP 6, m³/h under Pa or m³/h under Pa, engine power 7.5 kw - Right inlet version -ES D 400 mm W Left inlet version - ES D 400 mm W Filters ICP 8, m³/h under Pa or m³/h under Pa, engine power 9 kw - Right inlet version - ES D 450 mm W Left inlet version - ES D 450 mm W Filters ICP 10, m³/h under Pa or m³/h under Pa, engine power 11 kw - W W Filters ICP 12, m³/h under Pa or m³/h under Pa, engine power 15 kw - W W ICP filters, separated version with dusts recovery drum Filtres ICP 12 VS FP, m³/h under Pa or m³/h under Pa, engine power 15 kw - W W Filters ICP 16 VS FP, m³/h under Pa (cutting 22 kw) or m³/h under Pa (welding 15kW), engine 15 kw - Right inlet welding - ES D 560 mm W Left inlet welding - ES D 560 mm W Right inlet cutting- ES D 560 mm Left inlet cutting - ES D 560 mm W W Filters ICP 20 VS FP, m³/h under Pa (cutting 30kW) or m³/h under Pa (welding 22 kw), engine 15 kw - Right inlet welding - ES D 630 mm W Left inlet welding - ES D 630 mm W Right inlet cutting- ES D 630 mm Left inlet cutting - ES D 630 mm W W Filters ICP 24 VS FP, m³/h under Pa (cutting 30kW) or m³/h under Pa (welding 22 kw), engine 15 kw - Right inlet welding - ES D 710 mm W Left inlet welding - ES D 710 mm W Right inlet cutting- ES D 710 mm Left inlet cutting - ES D 710 mm W W Filters ICP 32 VS FP, m³/h under Pa (cutting 37 kw) or m³/h under Pa (welding 37 kw), engine 15 kw - Right inlet welding - ES D 710 mm W Left inlet welding - ES D 710 mm W Right inlet cutting- ES D 710 mm Left inlet cutting - ES D 710 mm W W
8 CLEANING FILTER I.C.P. The TOWER filters have the same features of all the ICP filters, but provide a low fixation to the ground if compared to a compact filter. The fan is placed under the filter block. TOWER filters are provided in 2 versions, dusts recovery drum for welding applications (TW FP), and BIG BAG with rotary airlock for PLASMA cutting applications and sanding grinding (TW ER), high fume or dusts release applications. Filter ICP 12 TOWER ER Filter ICP 12 VS ER Filter ICP 50 VS ER ICP TOWER FILTERS with dusts recovery drum Filters ICP 6 TW FP, m³/h under Pa or m³/h under Pa, engine power 7.5 kw - Right inlet version - ES D 400 mm W Left inlet version - ES D 400 mm W Filters ICP 8 TW FP, m³/h under Pa or m³/h under Pa, engine power 9 kw - Right inlet version - ES D 450 mm W Left inlet version - ES D 450 mm W Filters ICP 12 TW FP, m³/h under Pa or m³/h under Pa, engine power 15 kw - W W ICP filters with rotary airlock and BIG BAG Filters ICP 6 TW ER, m³/h under Pa or m³/h under Pa, engine power 7.5 kw - Right inlet version - ES D 400 mm W Left inlet version - ES D 400 mm W Filters ICP 8 TW ER, m³/h under Pa or m³/h under Pa, engine power 9 kw - Right inlet version - ES D 450 mm W Left inlet version - ES D 450 mm W Filtres ICP 12 TW ER, m³/h under Pa or m³/h under Pa, engine power 15 kw - W W ICP filters, separated version with rotary airlock and BIG BAG. Filters ICP 12 VS ER, m³/h under Pa or m³/h under Pa, engine power 15 kw - W W Filters ICP 16 VS ER, m³/h under Pa (cutting 22 kw) or m³/h under Pa (welding 15kW), engine 15 kw - Right inlet welding - ES D 560 mm W Left inlet welding - ES D 560 mm W Right inlet cutting- ES D 560 mm Left inlet cutting - ES D 560 mm W W Filters ICP 20 VS ER, m³/h under Pa (cutting 30kW) or m³/h under Pa (welding 22 kw), engine 15 kw - Right inlet welding - ES D 630 mm W Left inlet welding - ES D 630 mm W Right inlet cutting- ES D 630 mm Left inlet cutting - ES D 630 mm W W Filters ICP 24 VS ER, m³/h under Pa (cutting 30kW) or m³/h under Pa (welding 22 kw), engine 15 kw - Right inlet welding - ES D 710 mm W Left inlet welding - ES D 710 mm W Right inlet cutting- ES D 710 mm Left inlet cutting - ES D 710 mm W W Filters ICP 32 VS ER, m³/h under Pa (cutting 37 kw) or m³/h under Pa (welding 37 kw), engine 15 kw - Right inlet welding - ES D 710 mm W Left inlet welding - ES D 710 mm W Right inlet cutting- ES D 710 mm Left inlet cutting - ES D 710 mm W W
9 SPARE FILTERS ICP RANGE Qté Filtre ICP4 4 Filtration cartridge Filtre ICP6 6 Filtre ICP8 8 Filtre ICP10 10 Filtre ICP12 12 Filtre ICP 12VS, FP ou ER 12 Filtre ICP 16VS, FP ou ER 16 Filtre ICP 20 VS, FP ou ER 20 Filtre ICP 24VS, FP ou ER 24 Filtre ICP 32VS, FP ou ER 32 Filtre ICP 6TW, FP ou ER 6 Filtre ICP 8TW, FP ou ER 8 Filtre ICP 12TW, FP ou ER 12 Filtration cartridge polyester PFTE membrane, filtration class W3, EN 15012/1 compliant W Filtre ICP4 2 Metal pre-filters Filtre ICP6 2 Qté Filtre ICP8 2 Filtre ICP10 2 Filtre ICP12 3 Pre-filter 800 x 295 thickness 24 mm W Filtre ICP 12VS, FP or ER 2 Filtre ICP 16VS, FP or ER 2 Filtre ICP 20 VS, FP or ER 4 Filtre ICP 24VS, FP or ER 4 Filtre ICP 32VS, FP or ER 4 Filtre ICP 6TW, FP or ER 2 Filtre ICP 8TW, FP or ER 2 Filtre ICP 12TW, FP or ER 2 Pre-filter 610x610 thickness 24 mm W BIG BAG BIG BAG waterproof 740 x 740 x 740 W
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas
For extraction technology and occupational health & safety
The catalogue For extraction technology and occupational health & safety www.kemper.eu MaxiFil High capacity filter and safe filter change The Highlights:» Largest filter surface with mobile machines»
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
MECHANICAL MACHINING MINIPURE STATION FOR THE TREATMENT OF CUTTING AND PROCESS FLUIDS. www.siebec.com
MECHANICAL MACHINING MINIPURE STATION FOR THE TREATMENT OF CUTTING AND PROCESS FLUIDS Machining of aluminium, copper, cast iron and steels Machining of plastics and composite materials Deep hole drilling
BLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants
BLASTING SYSTEMS Turbine blasting systems Air blasting systems Automatic Painting plants 1, Dust Collector 2, Cyclone Separator 3, Sand (shot) Storage Hopper 4, Bucket elevator 5, Primary separator 6,
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
FOR SALE: RECYCLING PLANT FOR. - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC 28-90 HYDRO. Single shaft shredder
FOR SALE: RECYCLING PLANT FOR - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC 28-90 HYDRO Single shaft shredder Stationary, weight 40 ton Table of content Sale of BANO PREMAC
Energy saving in The air filtration field
Energy saving in The air filtration field Life cycle cost : 1. Cost of filter 2. Energy cost during its life 3. Costs of installation and replacement 4. Disposal Costs Generally speaking, the energy costs
How To Use A Most Powerful Welder For A Welding Machine
IV SUPPORTIVE EQUIPMENT CONTENTS 1. Filtroventilation devices 68 2. Welding gauges 71 3. Magnetic tools (mounting brackets) 72 67 www.most.com.pl 1. FILTROVENTILATION DEVICES MOSTAIR extraction arms MOST
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG
Installation and Operating Manual Model F1800C Model F1800PG Model F180C Model F180PG Model F1806C Model F1806PG www.ipsystemsusa.com Contents Safety Warnings... Items supplied... Description... Installation...4
OPERATING AND MAINTENANCE MANUAL
OPERATING AND MAINTENANCE MANUAL AUTOMATIC SCREEN FILTER FMA SERIE 5000 Sistemas de Filtrado y Tratamiento de Fluidos S.A. Pol. Industrial La Armentera Parc. 86 INDEX INTRODUCTION...3 TECHNICAL CHARACTERISTICS...5
BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: BENCH TECH 150 General information Type of instrument: Bench chemical hood. Model: Bench Tech 150. Code: 50-150-201 Description:
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
Cartridge Filter Application Notes
Industrial Water Purification (800) CAL-WATER Cal Water 1961 Petra Lane Placentia, CA 92870 FAX: (714) 792-0794 Web Page / Email: www.cal-water.com Cartridge Filter Application Notes Cal Water offers a
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
krones AirCo The air conveyor for PET bottles
The air conveyor for PET bottles The PET containers seem to be floating on air PET bottles should be treated gently. This is why the AirCo helps these sensitive lightweights float reliably and gently from
Spetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
The CLIPPER Solutions
The CLIPPER Solutions 111 112 C51 6,5 Hp Ø 350mm 76kg Compact, robust and highly manoeuvrable machines designed for both wet and dry cutting of concrete and asphalt. Machine delivered without diamond blade.
EVAC ONLINEVAC TECHNICAL DATA 6547655 EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13
Date: 9 Apr 202 Doc. 002967-6547655 6, 24 V DC Ø3 360 Required maintenance 990±0 960 40 040 20 890 350 (P/N 546664) 95±5 67±5 Vacuum sensor G /4 88±5 INLET DN40 943 Connection Frame: Steel S235 EN 0025
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements
Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements Introduction Objective: to estimate the CO2 emissions produced by road surface construction
Laminar Flow Cabinets and Workstations
VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic
Downflo workstation DuSt ColleCtorS
Downflo WorkStation Dust Collectors Outperforms All Other Collectors Downflo WorkStations (DWS) fit anywhere on the plant floor and apply NO restrictions to worker movements or visibility. The full line
Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF
Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake
Solar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
Atlas Copco Quality Air Solutions. Compressed Air Filters
Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational
RESERVDELSLISTA NORMFINISH DP14
1-A Glove L with lining 401100 1 pc 1-B Door L complete 400600 1 pc 1-C Main switch O-I 400101 1 pc 1-D START / STOP switch 400301 1 pc 1-E Fan motor 1,5 kw 400200 1 pc 1-F Gauge blast pressure 400400
Rittal TopTherm fan-and-filter unit
Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any
Cleaning of floor coverings. Vacuum Cleaners Brush-Type Vacuum Cleaners Spray Extractors Single Disc Machines Cleaning Machines - Cleanser
Cleaning of floor coverings Vacuum Cleaners Brush-Type Vacuum Cleaners Spray Extractors Single Disc Machines Cleaning Machines - Cleanser 135 7 Cleaning of floor coverings Vacuum Cleaners for Everyday
Pro Dry Heatless dessiccant compressed air dryers
Pro Dry Heatless dessiccant compressed air dryers Features Each Pro Dry unit has been designed to suit a multitude of requirements and is suitable for installation in many countries. The Pro Dry range
Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
Efficiency on a large scale CFB Steam Boilers
Efficiency on a large scale CFB Steam Boilers Circulating Fluidized Bed Steam Boiler The Circulating Fluidized Bed Steam Boiler is an offering from Bosch Thermotechnology a member of the worldwide Bosch
EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com
EcoCWave The all-round talent for aqueous part cleaning www.durr.com Part cleaning as a value-adding value-adding process process Increasing demands on cleanliness in component manufacturing impose a need
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Screw Compressors 11-22kW
INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature
The TransCut 300 plasma cutting system - Plasmacutting with liquid working medium
The TransCut 300 plasma cutting system - Plasmacutting with liquid working medium Speaker Sector Company Street Town Excellent portability with the TransCut 300 plasma cutting system Compact, portable
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: TRIMMING TECH 150 General information Type of instrument: Aspirated hood for histology. Model: Trimming Tech 150. Code: Description:
6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
VZ/VZM SERIES Heavy Duty Shredders 600-2,100 kg/h
VZ/VZM SERIES Heavy Duty Shredders 600-2,100 kg/h Technical Specifications VZ/VZM SERIES Heavy Duty Shredders VZ 17.00 / VZ 18.00 Inline set-up VZM 17.00 / VZM 18.00 Inline set-up Technical Data VZ/VZM
SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater
SALES SPECIFICATION SC7640 Auto/Manual High Resolution Sputter Coater Document Number SS-SC7640 Issue 1 (01/02) Disclaimer The components and packages described in this document are mutually compatible
Description & Working
Description & Working Quality... Automatic self-cleaning Filters: HSC Series Page 1 from 5 Range of application: Potable waters systems and treatment Waste water treatment Desalination Hydroelectric powerhouse
Espresso coffee grinder
Espresso coffee grinder 40A Espresso grinder 40A (Grey model) Internationally patented models L o n g l i f e, d e s i g n a n d s i l e n c e Silent espresso Fresh ground coffee gives the best espresso
Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90
6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2
Batching and Mixing Plants
Batching and Mixing Plants Technique Strength Results Ready-mix plant with sheeted, square steel in-line bins. Precast and pipe factory with concrete in-line bins and bucket elevator. Individual solutions
Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.
IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation
ASPHALT PLANT, NOMINAL PRODUCTION OF 160 T/H, IN
ASPHALT PLANT, NOMINAL PRODUCTION OF 160 T/H, IN Equipments are designed to reach the nominal production based in the following standard : - 3% aggregate moisture ; - sea level operation ; - aggregate
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS
FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer
OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw
OILFREE ROTARY SCROLL COMPRESSOR ECOLIFE 1, 1 kw EN Why The continuous innovation of the compressed air tools and machineries, the evolution of specific productive processes and uses, require exclusively
During Various Aluminum Fabricating Operations
Guidelines for Handling Aluminum Fines Generated During Various Aluminum Fabricating Operations F-1 Guidelines for Handling Aluminum Fines Generated During Various Aluminum Fabricating Operations SCOPE
ELECTRIC PERISTALTIC MORTAR POINTING PUMP
ELECTRIC PERISTALTIC MORTAR POINTING PUMP pointing gun & control valve ACF405 PERISTALTIC PuMP hopper feed roller & tube pump for refurbishment & repair trades heritage & conservation bridge & underground
O-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:
E X T E N D I N G Y O U R E N E R G Y DIESEL & JET FUEL FILTRATION EQUIPMENT Applications: Back-Up Diesel Generators Gas Turbines Fueling Terminals for Trucks & Buses Marine Mining Railroad Agriculture
1300 MAXTRAK SPECIFICATION
CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having
WASTE WATER TREATMENT for surface treatment applications
WASTE WATER TREATMENT for surface treatment applications Effluent an important cost factor Effluent cannot be avoided Water and compound are essential for vibratory mass finishing. During the finishing
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
The Nederman Design Guide
The Nederman Design Guide 1 2 Leading solutions for improved workspaces Nederman is the leading company with solutions based on capturing at source i.e. extraction of contaminants right at the point of
Series description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
CONDENSATE MANAGEMENT
CONDENSATE MANAGEMENT Innovative and integrated Systems Solutions Filtration Solutions from Donaldson Donaldson is a leading global manufacturer of filtration systems. The company, which was founded in
Multi-pollutant control solutions for coal based power plants
Multi-pollutant control solutions for coal based power plants By Luca Mancuso and Hans Janssen Content SOx control Wet Scrubbers Open towers Dual Flow Tray Technology Semi-Dry SDA CFB Scrubbers Dust control
Discharge station for bags and big bags. MKSB
Discharge station for bags and big bags. MKSB Discharge station for bags and big bags. One machine for two applications. The Bühler discharge station is versatile and flexible to use thanks to its modular
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
Sweepmaster 1200 / 1500 RH For the economic cleaning of large company premises
Cleaning Technology Municipal Technology Sweepmaster 1200 / 1500 RH For the economic cleaning of large company premises Ride-on sweepers for up to 16,200 m 2 /h area coverage Sweepmaster 1200 / 1500 RH
CONTINUOUS FLOW BREATHING AIR PURIFIERS
CONTINUOUS FLOW BREATHING AIR PURIFIERS CATALITE CBA SERIES dedicated to excellence... Since 1948, compressed air users around the world have relied on Hankison to provide innovative compressed air treatment
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
Durmazlar has aimed continous development since 1956
Head Quarter & Ataevler Durmazlar has aimed continous development since 1956 Owes one of the world s most contemporary production plants in the production technology business.3 different plants oriented
Weiss Mobile Air Conditioning Systems
Weiss Mobile Air Conditioning Systems SHELTER AIR CONDITIONING System Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik Worldwide... Weiss Umwelttechnik GmbH is one of the world s most important
Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade
Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial
LAMINAR FLOW CABINETS
LAMINAR FLOW CABINETS Vertical Laminar Flow Cabinets VLF 550 VLF650 VLF1000 VLF1200 VLF 1500 VLF1800 Monmouth Scientific's brand new range of Vertical laminar Flow (VLF) cabinets is available in six different
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
MOLECULAR DRAG PUMPS MDP SERIES
MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
Direct steam injection humidifiers
Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature
Innovative to the Core
Compressed Air Filter Ultra-Filter Innovative to the Core Significant Increase in Performance due to new Filtration Technology Besides electricity, water and gas, compressed air is one of the most coonly
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
BASIS RANGE TMB SERIES
BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver
Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process
Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process John Wertz Immo Schnieders Abstract Research and development of nanofibers has
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL
BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 2 Date : - 24/01/12 UNPACKING Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Waste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems
185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by
Gas Sample Probe Series SP
Embracing Challenge Gas Sample Probe Series SP Version SP3110V and SP3110 for sampling from zones with explosive gas with different options for calibration gas feeding, back purging and shut-off SP3110V/RS/HEX4-135
A sophisticated design for a demanding field. prima series
A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Stack Sampling Stack sampling or source sampling
Stack Monitoring Stack Sampling Stack sampling or source sampling may be defined as a method of collecting representative samples of pollutant laden air/gases at the place of origin of pollutants to determine