INCLINOMETER WITH CAN-BUS INTERFACE USER MANUAL
|
|
|
- Gavin Garrison
- 9 years ago
- Views:
Transcription
1 INCLINOMETER WITH CAN-BUS INTERFACE USER MANUAL
2 Imprint FRABA POSITAL GmbH Schanzenstraße 35 D Köln Telefon +49 (0) Telefax +49 (0) Internet Disclaimer of Warranty FRABA POSITAL GmbH makes no representations or warranties, either express or implied, by or with respect to anything in this manual, and shall not be liable for any implied warranties of merchantability and fitness for a particular purpose or for any indirect, special, or consequential damages. Copyright The company FRABA POSITAL GmbH claims copyright on this documentation. It is not allowed to modify, to extend, to hand over to a third party and to copy this documentation without written approval by the company FRABA POSITAL GmbH. Nor is any liability assumed for damages resulting from the use of the information contained herein. Further, this publication and features described herein are subject to change without notice. Version date: 18. April 2005 Version number: 1.4 Article number: Author: Efthimios Ioannidis Alteration of Specifications reserved Technical specifications, which are described in this manual, are subject to change due to our permanent strive to improve our products. Page 2 UME-AGS-CAN Version 09/04
3 1. Introduction Inclinometer CANopen technology CAN Communication Reference Model Definitions Installation Electrical Connection Bus Termination Bus address Troubleshooting Power on Inclinometer doesn t respond Malfunction of the position value during transmission Too much ERROR-Frames Information Device Configuration CANopen data transmission The COB-ID The Command Byte The Object Directory Operational Status Status: Operational Status: Pre-Operational Reset of the inclinometer Transmission of the Actual Position Programming Resolution Programming example: Resolution Operating ParameterLongitudinal Programming example: Operating Parameter Longitudinal Preset Value Longitudinal Programming example: Preset value Node-Guarding Guard-Time Lifetime-Factor Heartbeat-Function Heartbeat-Consumer: Programming example: Heartbeat-Consumer Heartbeat-Producer: Programming example:heartbeat-producer Changing the node number Example: Changing the node number Adjusting the baudrate Example : Adjusting the baudrate Transmission Mode Cyclic Mode Disable the cyclic mode Sync Mode Example: Number of Sync telegrams Polled Mode Memory Transfer Restore default parameters Technical Data Electrical Data Mechanical Data...32 Environmental Conditions Mechanical Drawings Bottom View Site View Front View Top View...34 Installation hints Models/Ordering Description Accessories and documentation List of Tables...36 Version 09/04 UME-AGS-CAN Page 3
4 1. Introduction This manual describes the implementing and configuration of an inclinometer with CANopen interface. The device fullfills the requirements of a CANopen device regarding the device specification DS410 of the CANopen user group. 1.1 Inclinometer The AGS CAN-Bus is a heavy duty absolute inclinometer with conductive technology and a fieldbus interface utilizing the CANBus protocol. With a maximum measuring range of +/- 30 and resolution up to 0.001, these inclinometers are used in a wide variety of position sensing applications for the measuring of inclinations. Mechanical features include an aluminum housing and IP66 protection. Electrical features include a linear and temperature compensated characteristic line, integrated SMD circuits, and over voltage peak protection. The inclinometer can be connected to a bus via an 8 pin connector. The termination resistor can be switched on by using a dip-switch. In addition the resolution is changeable via SDO object. For further information about the setup of a CANopen network please refer coder_abc.html Open functions. The following modes can be programmed and enabled or disabled: - Polled Mode - Cyclic Mode - Sync Mode The protocol supports the programming of the following additional functions: - Resolution - Preset value - Baudrate - Node number The general use of inclinometer with CAN-Bus interface using the CAN Open protocol is guaranteed. 1.2 CANopen technology CAN stands for Controller Area Network and was developed by the company Bosch for applications within the automobile area. In the meantime CAN has become increasingly used for industrial applications. CAN is a multimasterable system, i.e. all users can access the bus at any time as long as it is free. CAN doesn`t operate with addresses but with message identifiers. Access to the bus is performed according to the CSMA/CA principle (carrier sense multiple access with collision avoidance), i.e. each user listens if the bus is free, and if so, is allowed to send messages. If two users attempt to access the bus simultaneously, the one with the highest priority (lowest identifier) receives the permission to send. Users with lower priority interrupt their data transfer and will access the bus when it is free again. Messages can be received by every participant. Controlled by an acceptance filter the participant accepts only messages that are intended for it. CANopen Transmission Technology: Two-core cable Baud rates: 20 kbaud up to 1 MBaud Participants: maximum 127 Cable Length: 30 m for 1 MBaud 5000 m for 20 kbaud Page 4 UME-AGS-CAN Version 09/04
5 The data communication is done via message telegrams. In general, telegrams can be split in a COB-Identifier and up to 8 following bytes. The COB-Identifier, which determines the priority of the message, is made from the function code and the node number. The node number is uniquely assigned to each user. With the AGS inclinometer this number can be set via SDO object. The function code varies according to the type of message transmitted: After receiving a sync message by the host, the inclinometer answers with the current process value. If a node is not required to answer after each sync message, a parameter sync counter can be programmed to skip a certain number of sync messages before answering again - Change of state mode: The position value is transferred when changing - Administrative messages (LMT, NMT) - Service data objects (SDOs) - Process data Objects (PDOs) - pre-defined messages (synchronization, emergency messages) PDOs (Process Data Objects) are needed for real time data exchange. Since this messages possess a high priority, the function code and therefore the identifier are low. SDOs (service data objects) are necessary for the bus node configuration (e.g. transfer of device parameters). Because these message telegrams are tranferred acyclicly (usually only while powering up the network), the priority is low. Further functions (preset, resolution,etc..) can be parameterized. FRABA inclinometers correspond with the class 2 profile for inclinometer (DSP 410), whereby the characteristics of inclinometer with CANopen interface are defined. The link to the bus is made by a 8 pin connector. For configuration and parameterization various software tools are available from different providers. With the help of the provided EDS file (electronic datasheet) simple line-up and programming are possible. FRABA inclinometers with CANopen interface support all CANopen functions. The following operating modes can be programmed: - Polled mode: The position value is only given upon request - Cyclic Mode: The position value is written cyclically (interval adjustable) to the bus - Sync mode: Version 09/04 UME-AGS-CAN Page 5
6 1.3 CAN Communication Reference Model The communication concept can be described similar to the ISO-OSI Reference Model: Device A Device B Device C Device X ISO/OSI Layer 7: CAL NMT DBT LMT CMS ISO/OSI Layer 2: Data Link Layer ISO/OSI Layer 1: Physical Layer CAN Bus The communication model* supports synchronous and asynchronous messages. With respect to the functionality four different message objects are provided: Administrational Messages (LMT, NMT) Service Data Messages (SDO) Process Data Messages (PDO) Pre-defined Messages (Synchronisation and Emergency Messages) Further information is available at: CAN in Automation (CiA) International Users and Manufacturers Group e.v. Am Weichselgarten 26 D Erlangen (*) Reference: CAN Application Layer for Industrial Applications CiA Draft Standard , Version 1.1 CAL-based Communication Profile for Industrial Systems CiA Draft Standard 301 Page 6 UME-AGS-CAN Version 09/04
7 1.4 Definitions CAN Controller Area Network CAL CAN Application Layer CMS CAN Message Specification. One of the service elements of the application layer in the CAN Reference Model. COB Communication Object. (CAN message) A unit of transportation in a CAN Network. Data must be sent across a Network inside a COB. COB-ID COB-Identfier. Identifies a COB uniquely in a Network. The identifier determines the priority of that COB. LMT Layer Management. One of the service elements of the application layer in the CAN Reference Model. It serves to configure parameters of each layer in the CAN Reference Model. NMT Network Management. One of the service elements of the application layer in the CAN Reference Model. It performs initialisation, configuration and error handling in a CAN network. SDO Service Data Object. A data object with low priority to configure a CAN node. PDO Process Data Object. A data object with high priority to transmit data in synchronous and asynchronous modes. Additionally, following abbreviations are used in the manual: FC Function code. It determines the kind of message, which is sent across the CAN network. NN Node number. It determines uniquely the CAN device. PV Preset value PCV Process value Version 09/04 UME-AGS-CAN Page 7
8 2. Installation 2.1 Electrical Connection The inclinometer is connected via 8 pin round connector Instructions to mechanically install and electrically connect the inclinometer 2.2 Bus Termination If the inclinometer is connected at the end or beginning of the bus the termination resistor must be switched on. The termination resistor is switched on when the dip-switch 8 is in the ON position. To switch the resistor on, the cap of the inclinometer has to be unscrewed. Do not connect the inclinometer under power! There is a resistor provided in the inclinometer, which must be used as a line termination on the last device. ON OFF Do not stand on the inclinometer! 2.3 Bus address Avoid mechanical load! Pin Description 1 24 V Supply voltage V Supply voltage 5 CAN Low 6 CAN Ground 7 CAN High 8 The setting of the node number is achieved via SDO-Object (see 4.4). Possible (valid) addresses lie between 0 and 96 whereby every address can only be used once. The CANopen inclinometer adds internal 1 to the adjusted device address. Tabelle 1 Connector Assignment 8 pin round connector connector male inlay Page 8 UME-AGS-CAN Version 09/04
9 2.4 Troubleshooting Power on Inclinometer doesn t respond Problem: The bus is active but the installed inclinometer transmitted the false node number. Possible solution: - modus pre-operational - adressing the inclinometer via SDO - reset or power off - power on Malfunction of the position value during transmission Problem: During the transmission of the position value occasional malfunctions occur. The CAN bus can be temporabily in the bus off state also. Possible solution: Check, if the last bus nodes have switched on the terminal resistor. If the last bus node is an inclinometer the terminal resistor is to activate Too much ERROR-Frames Problem: The bus load is too high in case of too much error frames. Possible solution: Check if all bus node has the same baudrate. If one node has another baudrate error frames are produced automatically. The setting of the baudrate is descripted in this manual under Information Notice: The changing of baudrate and node number is only valid after a new power up, NMT Reset or the store parameters command. Version 09/04 UME-AGS-CAN Page 9
10 3. Device Configuration 3.1. CANopen data transmission The data transmission in the CAN network is realised by message telegrams. Basically, these Telegrams can be divided into the COB-ID and 8 following bytes as shown in the table below: COB-ID Command Index Subindex Service-/Process- Data 11 Bit Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Low High Low High The COB-ID The 11 Bit of COB-Identifier is built as follows: Function code Node number X X X X X X X X X X X X: free selectable The COB-Identifier determines uniquely the message object. It is built by the function code, identifying the message class and the node number, which determines the inclinometer. The node number can be adjusted by on customer request by a SDO. Following function codes are available: (rx) and (tx) as seen by the master! Object Function Code (Binary) Result. COB-ID Priority Class* NMT SYNC Emergency ,1 PDO (rx) ,2 PDO (tx) PDO (rx) ,3 PDO (tx) ,4 SDO (rx) SDO (tx) ,7 Tabelle 2 Overview priority of the CANopen objects *Priority: 0 = highest priority, 7 = lowest priority Page 10 UME-AGS-CAN Version 09/04
11 3.1.2 The Command Byte The command byte contents the kind of telegram which is sent across the CAN network. One divides three kinds of telegrams: a Set-Parameter- Telegram (Domain Download), a Request- Telegram (Domain Upload) and Warnings. The Set-Parameter-Telegram is used to send parameter data to the inclinometer (node) for configuration. The Request-Telegram is used by the master to read back stored parameters from a node. Warnings are sent by the inclinometer to the master, if a sent telegram cannot be processed accordingly. Command Function Telegram Description 22h Domain Download Request Parameter to inclinometer 60h Domain Download Confirmation Parameter received 40h Domain Upload Request Parameter request 43h, 4Bh, 4Fh (*) Domain Upload Reply Parameter to Master 80 h Warning Reply Transmission error Tabelle 3 Command description (*)The value of the command byte depends on the data length of the called parameter: Command Data length Data length 43h 4 Byte Unsigned 32 4Bh 2 Byte Unsigned 16 4Fh 1 Byte Unsigned 8 Tabelle 4 Data length against command byte Version 09/04 UME-AGS-CAN Page 11
12 3.1.3 The Object Directory The data transmission according to CAL is realised exclusively by object oriented data messages. The objects are classified in groups by an index record. Each index entry can be subdivided by subindices. The overall layout of the standard object dictionary is shown beside: Index (hex) Object 0000 not used F Static Data Types F Complex Data Types F Manufacturer Specific Data Types FFF Reserved for further use FFF Communication Profile Area FFF Manufacturer Specific Profile Area FFF Standardised Device Profile Area A000-FFFF Reserved for further use Tabelle 5 General object dictionary Following objects according to the communication profile CAN OPEN (refer tods301) are implemented into the inclinometer encoder: Index Subindex Object Name Data Length Attr. 1000h VAR Device type Unsigned32 const 1001h VAR error register Unsigned8 ro 1002h VAR manufacturer status register Unsigned32 ro 1003h ARRAY pre-defined error field Unsigned32 ro 1004h Reserved for compatibility reason 1005h VAR COB-ID SYNC-message Unsigned32 rw 1008h VAR device name Vis-String const 1009h VAR hardware version Vis-String const 100Ah VAR software version Vis-String const 100Bh Reserved for compatibility reason 1010h 1h VAR Store parameters Unsigned32 rw 1011h 1h VAR Restor parameters Unsigned32 rw 1016h ARRAY Consumer Heartbeat Time Unsigned32 ro 1017h VAR Producer Heartbeat Time Unsigned32 rw 1800h RECORD Communication parameter PDO 1 ro 1800h 0h VAR number of supp. entries Unsigned8 ro 1800h 1h VAR COB-ID used by PDO Unsigned32 rw 1800h 2h VAR transmission type Unsigned8 rw 1801h RECORD Communication parameter PDO 2 ro 1801h 0h VAR number of supp. entries Unsigned8 ro 1801h 1h VAR COB-ID used by PDO Unsigned32 rw 1801h 2h VAR transmission type Unsigned8 rw Tabelle 6 Object dictionary according DS301 Page 12 UME-AGS-CAN Version 09/04
13 Index Subindex Objekt Name Datenlänge Attr. 6000h VAR Resolution Unsigned16 rw 6010h VAR Slope Longitudinal Signed16 ro 6011h VAR Operating Parameter Longitudinal Unsigned8 rw 6012h VAR Preset Longitudinal Signed16 rw 6020h VAR Slope Lateral Signed16 ro 6021h VAR Operating Parameter Lateral Unsigned8 rw 6022h VAR Presetwert Lateral Signed16 rw Tabelle 7 Object dictionary according DS 410 Additionally, following manufacturer specific communication objects are implemented: Index Subindex Objekt Name Datenlänge Attr. 3000h VAR Knotennummer Unsigned 8 rw 3001h VAR Datenrate Unsigned 8 rw Tabelle 8 Nodenumber and baudrate Index Subindex Object Name Data length Attr. 2200h VAR Cycle time Unsigned16 rw Tabelle 9 Manufacturer specific object dictionary VAR: Variable RECORD: Data field ARRAY: Data field ro: read only rw: read, write wo: write only Version 09/04 UME-AGS-CAN Page 13
14 3.2 Operational Status The inclinometer accesses the CAN network 4 s after power on in pre-operational status: FC NN Comand Index Subindex S-/P-Data Description 1110 XXXXXXX Boot-Up message All values except the FC are hexadecimal It is recommended, to set the parameters (see: 4 Programming) while the inclinometer is in the preoperational status. During this status activity on the network is low what makes it easier to prove the correctness of the sent/received SDOs. As it is not possible to send or receive PDOs in preoperational status, stress for the inclinometer will be reduced Status: Operational To put one or all nodes in the operational state, following message is sent by the master: FC NN Command Index Subindex S-/P-Data Description 0000 b 0 d 01 h 00 NMT-Start, all nodes 0000 b 0 d 01 h NN NMT-Start, NN It is possible to put all the nodes in operational status (Index 0) or only one node (Index NN) Status: Pre-Operational To set one node in the Pre-Operational state the following telegram has to be transmitted from the master: FC NN Command Index Subindex S-/P-Data Description 0000 b 0 d 80 h NN NMT-PreOp, NN NN: node number Page 14 UME-AGS-CAN Version 09/04
15 3.2.3 Reset of the inclinometer If a node is not functioning well, it is recommended to perform a RESET: FC NN Command Index Subindex S-/P-Data Description 0000 b 0 d 81 h NN NMT-Reset, NN NN: node number The notified inclinometer accesses the bus in pre-operational status after resetting. 3.3 Transmission of the Actual Position The process value is sent across the CAN network with the following telegram: COB-ID Process value 11 Bit Byte 0 Byte 1 Byte 2 Byte to to to to 2 24 The COB-ID contains the node number and the according PDO(rx). By default the process value is sent with the function code PDO(rx) 0011 and as a response to the Sync-telegram with the function code PDO(rx) Programming The setting of parameters should be done always in pre-operational status. The monitoring of the sent and received messages becomes much easier. It is important to follow the presented sequence of the parameter settings. If values of parameters are not changed then they can be skipped. Following values are written in hexadecimal notation with the exception of the function code which value is given binary and the node number (decimal value). Every parameter has a general description and an example. Version 09/04 UME-AGS-CAN Page 15
16 4.1 Resolution The parameter Resolution is used to program the desired number of steps per 1. The resolution is adjustable between 0,001 and 1. CMS Index Default value Value range Data length SDO 6000h Unsigned 16 Unsigned16 General parameter description Master to Inclinometer: Set-Parameter SDO(tx) Download 6000h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X 0 0 X: desired resolution Only the follow values can be use to programming the resolution : 1h 0,001 Ah 0,01 64h 0,1 3E8h 1 After a successful transmission the inclinometer answered with the following confirmation telegram: SDO(rx) Download 2101h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Page 16 UME-AGS-CAN Version 09/04
17 4.1.1 Programming example: Resolution Target: Inclinometer with 1 step per 1 Value: 1000 = 3E8 h Node Number NN = 1 Master to Inclinometer: Set-Parameter SDO(tx) Download 6000h Byte 4 Byte 5 Byte 6 Byte b 1-90 d E Inclinometer to Master: Confirmation SDO(rx) Download 6000h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Operating ParameterLongitudinal This object determines the interpretation of the Slope Longitudinal value. CMS Index Default value Value range Data length SDO 6011h 0 Unsigned 8 Unsigned8 General parameter description Master to Inclinometer: Set-Parameter SDO(tx) Download 6011h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X: Operating Parameter Function 0 1 Scaling X Y X: Slope Longitudinal = physically measured value + Offset Y: Slope Longitudinal = physically measured value The inclinometer is setting on X by delivery. Version 09/04 UME-AGS-CAN Page 17
18 4.2.1 Programming example: Operating Parameter Longitudinal Target: Setting the inclinometer on Slope Longitudinal = physically measured value. Value:0 Master to Inclinometer: Set-Parameter SDO(tx) Download 6011h Byte 4 Byte 5 Byte 6 Byte b 01 d Inclinometer to Master: Confirmation SDO(rx) Download 6011h Byte 4 Byte 5 Byte 6 Byte b 01 d The procedure to programming the Operating Parameter Lateral (object 6021h) is the same like Operating Parameter Longitudinal. Page 18 UME-AGS-CAN Version 09/04
19 4.3 Preset Value Longitudinal The preset value is the desired position value, which should be reached at a certain physical position of the axis. The position value is set to the desired process value by the parameter preset. CMS Index Default value Value range Data length SDO 6012h 0h 0h - total resolution Unsigned32 General parameter description Master to inclinometer: Set-Parameter SDO(tx) Download 6000h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X X X X: desired preset value After a successful transmission the inclinometer answered with the following confirmation telegram: SDO(rx) Download 6000h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Programming example: Preset value Target: Inclinometer with the preset value 0 Preset value 0 is equivalent to X = 0h Node number NN = 1 Master to Inclinometer: Set-Parameter SDO(tx) Download 6000h Byte 4 Byte 5 Byte 6 Byte b 01 d Inclinometer to Master: Confirmation SDO(rx) Download 6000h Byte 4 Byte 5 Byte 6 Byte b 01 d The procedure to programming the Preset Value Lateral (object 6022h) is the same like Preset Value Longitudinal. Version 09/04 UME-AGS-CAN Page 19
20 4.4 Node-Guarding The NMT Master polls each NMT Slave at regular time intervals. This time-interval is called the Guard-Time and may be different for each NMT Slave. The response of the NMT Slave contains the state of that NMT Slave Guard-Time CMS Index Default value Value range Data length SDO 100Ch 0h Unsigned 16 Unsigned 16 General parameter description Master to inclinometer: Set-Parameter SDO(tx) Download 100Ch Byte 4 Byte 5 Byte 6 Byte b 1-90 d 22 0C X X 0 0 X: Time in ms X is the Guard-Time which the NMT-Master polls the NMT-Slave After a successful transmission the inclinometer answered with the following confirmation telegram: SDO(rx) Download 100Ch Byte 4 Byte 5 Byte 6 Byte b 1-90 d 60 0C Programming example: Guard-Time Target: The Master send at a time of 1000ms Guard-Time = Time 1000ms (03E8h) Master to inclinometer: Set-Parameter SDO(tx) Download 100Ch Byte 4 Byte 5 Byte 6 Byte b 01 d 22 0C E Inclinometer to Master: Confirmation SDO(rx) Download 100Ch Byte 4 Byte 5 Byte 6 Byte b 01 d 60 0C Page 20 UME-AGS-CAN Version 09/04
21 4.4.3 Lifetime-Factor The product from the Lifetime-Faktor and the Guard-Time is that time, where the Slave has to recieve a remote-transmission-telegram from the Master. CMS Index Defaultwert Wertebereich Datenlänge SDO 100Dh 0h Unsigned 8 Unsigned 8 General parameter description Master to inclinometer: Set-Parameter SDO(tx) Download 100Dh Byte 4 Byte 5 Byte 6 Byte b 1-90 d 22 0D X X: Factor After a successful transmission the inclinometer answered with the following confirmation telegram: SDO(rx) Download 100Dh Byte 4 Byte 5 Byte 6 Byte b 1-90 d 60 0D Programming example: Lifetime-Faktor Target: The Slave has to receive a remote-transmission-telegram not later than 3000ms from the Master Faktor = 3 Master to inclinometer: Set-Parameter SDO(tx) Download 100Dh Byte 4 Byte 5 Byte 6 Byte b 01 d 22 0D Inclinometer to Master: Confirmation SDO(rx) Download 100Dh Byte 4 Byte 5 Byte 6 Byte b 01 d 60 0D To switch off the Node-Guarding the Guard-Time and the Lifetime-Faktor has to set to zero. Version 09/04 UME-AGS-CAN Page 21
22 4.5 Heartbeat-Function With the Heartbeat-Function each node can control another node in a network. For more information please look to the specifikation DS301Vers Heartbeat-Consumer: CMS Index Default value Value range Data length SDO 1016h 0h Unsigned 32 Unsigned 32 General parameter description Master to inclinometer: Set-Parameter SDO(tx) Download 1016h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X Y 0 X: Time in ms To ensure a secure functionality the Consumer-Time has to be approximately 100ms greater than the Producer- time. Y: Node number of the producer After a successful transmission the inclinometer answered with the following confirmation telegram: SDO(rx) Download 1016h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Page 22 UME-AGS-CAN Version 09/04
23 4.5.2 Programming example: Heartbeat-Consumer Target: The Producer send with 1000ms and contains the node number 1 Consumer = Time 1100ms = 044Ch, node number 1 Node number = 01h Master to inclinometer: Set-Parameter SDO(tx) Download 1016h Byte 4 Byte 5 Byte 6 Byte b 01 d C Inclinometer to Master: Confirmation SDO(rx) Download 1016h Byte 4 Byte 5 Byte 6 Byte b 01 d Heartbeat-Producer: CMS Index Default value Value range Data length SDO 1017h 0h Unsigned 16 Unsigned 32 General parameter description Master to inclinometer: Set-Parameter SDO(tx) Download 1017h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X 0 0 X: Time in ms After a successful transmission the inclinometer answered with the following confirmation telegram: SDO(rx) Download 1017h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Version 09/04 UME-AGS-CAN Page 23
24 4.5.4 Programming example:heartbeat-producer Target: Producer-Time 1000ms Time in ms: X = 03E8h Node number = 01h Master to inclinometer: Set-Parameter SDO(tx) Download 1017h Byte 4 Byte 5 Byte 6 Byte b 01 d E Inclinometer to Master: Confirmation SDO(rx) Download 1017h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Changing the node number CMS Index Defaultvalue Value range Data length SDO 3000h 20h 0h-89h Unsigned 8 General parameter description FC KN Command Index Subindex Service-/Processdata SDO(tx) Download 3000h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X After successful transmission the inclinometer answered with the following telegram: FC NN Command Index Subindex Service-/Processdata SDO(rx) Download 3000h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Page 24 UME-AGS-CAN Version 09/04
25 4.6.1 Example: Changing the node number Target: Inclinometer with node number 5 Default node number: 32 d The changed node number is confirmed by the inclinometer but only after a - Store command (Objekt 2300 hex) - Store command (Objekt 1010 hex) and NMT reset module or NMT reset communikation valid. To adjust the node number only one byte is used whereby the inclinometer adds one to the programmed value. Setting node number 5: Bit value example * = = 5 node number Master to Inclinometer: Set-Parameter FC NN Command Index Subindex Service-/Processdata SDO(tx) Download 3000h Byte 4 Byte 5 Byte 6 Byte b 32 d X: 7 Bit to adjust the node number Inclinometer to Master: Confirmation FC NN Command Index Subindex Service-/Processdata SDO(rx) Download 3000h Byte 4 Byte 5 Byte 6 Byte b 32 d Version 09/04 UME-AGS-CAN Page 25
26 4.7 Adjusting the baudrate CMS Index Defaultvalue Value range Data length SDO 3001h 20h 0h-8h Unsigned 8 General parameter description FC NN Command Index Subindex Service-/Processdata SDO(tx) Download 3001h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X: 4 Bit to adjust the Baudrate After successful transmission the inclinometer answered with the following telegram: FC NN Command Index Subindex Service-/Processdata SDO(rx) Download 3001h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Nine different baudrates are provided. To adjust the baudrate only one byte is used. Adjusting Baudrate: Baudrate in kbit/s Bit Page 26 UME-AGS-CAN Version 09/04
27 The changing of the baudrate is confirmed by the inclinometer but is only saved after a - Store command (object 2300 hex) - Store command (object 1010 hex) and NMT Reset Modul or NMT Reset communikation Example : Adjusting the baudrate Target: Inclinometer with a baurate of 250 kbaud Default baudrate: 20 kbaud Default node number: NN = 32 d FC NN Command Index Subindex Service-/Processdata SDO(tx) Download 3001h Byte 4 Byte 5 Byte 6 Byte b 32 d After successful transmission the encoder answered with the following telegram: FC NN Command Index Subindex Service-/Processdata SDO(rx) Download 3001h Byte 4 Byte 5 Byte 6 Byte b 32 d Transmission Mode Cyclic Mode The inclinometer transmits cyclic - without being called by the host - the current process value. The cycle time can be programmed in milliseconds for values between 1 ms and ms (e.g.: 64h = 100ms). CMS Index Default value Value range Data length SDO 2200h 64 h 1h h Unsigned16 General parameter description Master to Inclinometer: Set-Parameter SDO(tx) Download 2200h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X X: desired cycle time Version 09/04 UME-AGS-CAN Page 27
28 Inclinometer to Master: Confirmation SDO(rx) Download 2200h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Disable the cyclic mode To switch off the cyclic mode of the inclinometer the following telegram (cyclic mode disable) can be sent: Master to Inclinometer: Set-parameter SDO(tx) Download 2200h 0h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Inclinometer to Master: Confirmation SDO(rx) Download 2200h 0h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Sync Mode After reception of the SYNC-telegram by the host the inclinometer sends the actual position value. If multiple nodes are programmed for the SYNC-mode they answer following their COB- Ids. The programming of an offset time is not applicable. It is also possible to program a number of SYNC telegrams which are ignored CMS Index Subindex Defaultwert Value range Data length SDO 1802h 2h 1h 1h - 100h Unsigned 8 General parameter description SDO(tx) Download 1802h 2h Byte 4 Byte 5 Byte 6 Byte b 1-90 d X X: number of Sync-Telegrams after which the inclinometer sends the process value Page 28 UME-AGS-CAN Version 09/04
29 Inclinometer to Master: Confirmation SDO(rx) Download 1802h 2h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Like the cyclic mode also the sync mode can be switched off the same way. To do this the PDO 2 must be addressed with the Index 1802h Example: Number of Sync telegrams Target: Inclinometer with 3 SYNC telgrams Number of SYNC telegrams: X = 03h Node number: NN = 01 d SDO(tx) Download 1802h 2h Byte 4 Byte 5 Byte 6 Byte b 01 d Absolute Inclinometer to Master: Confirmation SDO(rx) Download 1802h 2h Byte 4 Byte 5 Byte 6 Byte b 01 d Polled Mode By a remote-transmission-request telegram the connected host calls off the current process value. The inclinometer reads the current position value, calculates eventually setparameters and sends back the obtained process value by the same COB-ID. The PDO (rx) with the function code 0011 is used from the inclinometer to transmit the position value. This kind of Transmission mode must only be used in status operational. CMS Remote Transmission Request Bit (RTR) Datenlänge PDO 1 0 Version 09/04 UME-AGS-CAN Page 29
30 4.9 Memory Transfer The parameter settings can be stored in a nonvolatile Flash-EPROM. The parameter settings are stored in RAM when being programmed, because of the limited number of burn cycles of the Flash- EEPROM ( 1.000). When all the parameters are set and proved, they can be transferred in one burn cycle to the Flash-EEPROM by the parameter memory transfer. The stored parameters are copied after a RESET (Power on, NMT-Reset) from the Flash-EPROM to the RAM (volatile memory). The stored parameters are copied after a RESET (Power on, NMT-Reset) from the Flash-EPROM to the RAM (volatile memory). Attention: The operating mode SYNC or CYCLIC is not saved in the inclinometer. After a reset or power up the cyclic mode is always started as standard. To switch off the cyclic on you must deactivate the cyclic mode in the state preoperational. After that you could start the operational state. CMS Index Value Data Type SDO 2300h 55 AA AA 55 h Unsigned 32 Master to Inclinometer: Set-Parameter SDO(tx) Download 2300h Byte 4 Byte 5 Byte 6 Byte d AA AA 55 If the transfer is successful the inclinometer quotes after 4s with the pre-operational status with a Boot-Up message. An additional possibility to store the parameter is to use the SDO object The following parameter has to transmitted to the encoder: CMS Index Value: Data length SDO 1010h h Unsigned 32 Master to Inclinometer: Set-Parameter FC NN Command Index Subindex Service-/Processdata SDO(tx) Download 1010h Byte 4 Byte 5 Byte 6 Byte b 1-90 d Page 30 UME-AGS-CAN Version 09/04
31 4.10 Restore default parameters The default parameters can be restored. The already in the non-volatile memory programmed parameters are not overwritten. Only after a new store command the default parameters are stored in the non-volatile memory. To restore the default parameter the following telegram is used. CMS Index Value: Data length SDO 1011h 6C 6F h Unsigned 32 Master to Inclinometer: Set-Parameter FC NN Command Index Subindex Service-/Processdata SDO(tx) Download 1011h Byte 4 Byte 5 Byte 6 Byte b 1-90 d C 6F Technical Data 5.1. Electrical Data Model AGS 5 AGS 15 AGS 30 Measuring range +/- 5 +/- 15 +/- 30 Resolution 0,001 0,001 0,005 Accuracy (T = 0 C C) 0,06 0,18 0,40 Accuracy (T = -25 C. +85 C) 0,12 0,30 1,00 Damping period (0 -> 15, t=90%) typ. 1,25s Interface Transceiver according ISO 11898, galvanically isolated by opto-couplers Transmission rate max. 1 MBaud Device addressing Via SDO Supply voltage V DC (absolute limits) Current consumption max. 230 ma with 10 V DC, max. 100 ma with 24 V DC Power consumption max. 2,2Watts EMC Emitted interference: EN Noise immunity: EN Electrical lifetime > 10 5 h Tabelle 10 Electrical data Inclinometer should be connected only to subsequent electronics whose power supplies comply with EN (protective low voltage) Version 09/04 UME-AGS-CAN Page 31
32 5.2. Mechanical Data Housing Lifetime Shock (EN ) Vibration (EN ) Weight (standard version) Aluminum > 10 5 h A=30g; t= 11ms, halfsine 10 to 150 Hz, 2,5 mm amplitude, 5g const. Acceleration, 1 Octave /Minute (EN ) 350 g Tabelle 11 Mechanical data Environmental Conditions Operating temperature Storage temperature Humidity Protection class (EN 60529) -25 C C -40 C C 98 % (without liquid state) IP 67 (connected) Tabelle 12 Environmantal conditions Page 32 UME-AGS-CAN Version 09/04
33 5.3 Mechanical Drawings Bottom View Side View Version 09/04 UME-AGS-CAN Page 33
34 5.3.3 Front View Top View Page 34 UME-AGS-CAN Version 09/04
35 Installation hints Both the cable shielding and the metal housings of encoders and subsequent electronics have a shielding function. The housing must have the same potential and be connected to the main signal ground over the machine chassis or by means of a separate potential compensating line. Potential compensating lines should have a minimum cross section of 6 mm2. Do not lay signal cable in the direct vicinity of interference sources (air clearance > 100 mm (4 in.). A minimum spacing of 200 mm (8 in.) to inductors is usually required, for example in switch-mode power supplies. Configure the signal lines for minimum length and avoid the use of intermediate terminals. In metal cable ducts, sufficient decoupling of signal lines from interference signal transmitting cable can usually be achieved with a grounded partition. 6. Models/Ordering Description Description Typekey Absolute inclinometer AGS H Measuring range Number of axis Interface CA Version Mechanical construction horizontal Dynamik 2 mpas Connection connector, 8 pin P8M 1 m cable CRW Option without - Tabelle 13 Ordering Description Version 09/04 UME-AGS-CAN Page 35
36 6.1 Accessories and documentation Description Typ Mating Connector P8F Cabel Cabel STK 8, 2m, Connector P8F P8F-STK8.2 Cabel STK 8, 5m, Connector P8F P8F-STK8.5 User manual * Installation and configuration manual, german UMD-AGS-CA User manual * Installation and configuration manual, english UME-AGS-CA EDS-File * Disc containing EDS-file for configuration DK-AGS-CA Tabelle 14 Accessories * These can be downloaded free of charge from our Homepage We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice. 7 List of Tables Tabelle 1 Connector Assignment...8 Tabelle 2 Overview priority of the CANopen objects...10 Tabelle 3 Command description...11 Tabelle 4 Data length against command byte...11 Tabelle 5 General object dictionary...12 Tabelle 6 Object dictionary according DS Tabelle 7 Object dictionary according DS Tabelle 8 Nodenumber and baudrate...13 Tabelle 9 Manufacturer specific object dictionary...13 Tabelle 10 Electrical data...31 Tabelle 11 Mechanical data...32 Tabelle 12 Environmantal conditions...32 Tabelle 13 Ordering Description...35 Tabelle 14 Accessories...36 Page 36 UME-AGS-CAN Version 09/04
LENORD. +BAUER... automates motion. Fieldbus connection absolute encoders CANopen. Reference. Communication profile DS-301 Device profile DS-406
Fieldbus connection absolute encoders CANopen Communication profile DS-30 Device profile DS-406 LENORD +BAUER... automates motion. Reference D-0R-xCO (.) Right to technical changes and errors reserved.
ACCELENS (ACS) INCLINOMETER WITH CANOPEN INTERFACE
ACCELENS (ACS) INCLINOMETER WITH CANOPEN INTERFACE User Manual AMERICAS FRABA Inc. 1800 East State Street, Suite 148 Hamilton, NJ 08609-2020, USA T +1 609 750-8705, F +1 609 750-8703 www.posital.com, [email protected]
Positioning Controller
Edition May 2008 Positioning Controller Application Note "CANopen Basic Information" Edition May 2008 EPOS 24/1, EPOS 24/5, EPOS 70/10, MCD EPOS 60W, EPOS2 50/5 Firmware version 2000h or higher Introduction
Jena er Antriebstechnik. GmbH. 1. Introduction. 2. Properties. 3. Hardware. 4. Baud Rates. Brief Instructions - CANopen Interface
Project : ECOSTEP 100/200 Application Note No. 23 Page 1 of 10 Prepared by: Henrik Bräutigam Operation of ECOSTEP at CANopen Bus Date: 05-01-05 Brief Instructions - CANopen Interface 1. Introduction The
EUROMAP 66-1. Protocol for Communication with Peripheral Equipment. General Description
EUROMAP 66-1 Protocol for Communication with Peripheral Equipment General Description Version 1.2, December 2002 (10 pages) This recommendation was prepared by the Technical Commission of EUROMAP. History
ABSOLUTE ROTARY ENCODER ETHERNET/IP
Main Features - Compact and heavy duty industrial model - Interface: EtherNet/IP - Conformance tested by ODVA - Housing: 58 mm - Full shaft: 6 or 10 mm / hollow shaft15 mm - Resolution: max. 30 Bit = 1,073,741,824
CANopen Fieldbus Documentation
CANopen Fieldbus Documentation 5th generation of inverter FUNDAMENTALS COMMUNICATION PARAMETERS V 5.3 04/2007 GB MI BCI AM Fieldbus Applications POSI Switch CANopen 5th Generation of Inverters Table of
CIA405.lib. Contents. WAGO-I/O-PRO 32 Library
Appendix A Additional Libraries WAGO-I/O-PRO 32 Library CIA405.lib Contents CIA405_GET_KERNEL_STATUS...3 CIA405_GET_LOCAL_NODE_ID...4 CIA405_RECV_EMY...5 CIA405_RECV_EMY_DEV...6 CIA405_GET_STATE...7 CIA405_SDO_READ21...8
RPDO 1 TPDO 1 TPDO 5 TPDO 6 TPDO 7 TPDO 8
EN ZC - 6DI8DO CANopen I/O Module 6 Digital Input 8 Digital Output Or 8 Counters (3 bit) 8 Digital input 8 Digital output User Manual Contents: Features PDOs PDO Type Emergency Message Functional Diagrams
TD-03011E. Identifier Usage in CANopen Networks
Identifier Usage in CANopen Networks Author : U. Koppe Published : January 2003 This document describes the usage of identifiers in CANopen networks. The paper is intended for CANopen newcomers and system
CANopen Communication Protocol
Users' Manual for SM 137 - SM 140 motors H5834D0009ING 02 05/15/2007 CANopen Communication Protocol S.r.l. Publication information Update List Revision Added Deleted Changed 00 Unreleased 01 Sect. 9.1
Getting Started with CANopen Version 1.1 2008-05-29 Application Note AN-AON-1-1102
Version 1.1 2008-05-29 Restrictions Abstract Public Document This application note explains items which need to be considered when creating a CANopen device or system. The Manager, Systems Engineer, and
SANMOTION AC SERVO SYSTEMS
SANMOTION AC SERVO SYSTEMS WITH R SD2-071126-01-KM INTERFACE Instruction Manual SANYO DENKI About This Manual Overview This document is part of SANMOTION R-series servo amplifier manual, provided by SANYO
ANTAL ELECTRONIC Field Bus and Communication Technology. Manual PDP2CAN. Version 3.08
ANTAL ELECTRONIC Field Bus and Communication Technology Manual PDP2CAN Version 3.08 ANTAL ELECTRONIC Höfles 4 91322 Gräfenberg Telefon (+49) 09192/9256 0 Fax (+49) 09192/9256 78 Important Notice Antal
GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0
GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...
Absolute rotary encoder GEL 235EC
Absolute rotary encoder GEL 235EC EtherCAT fieldbus interface Reference D-02R-235EC (1.1) Right to technical changes and errors reserved. 2011-11 Device manufacturer and publisher: Lenord, Bauer & Co.
DeviceNet Communication Manual
DeviceNet Communication Manual Soft-Starter Series: SSW-07/SSW-08 Language: English Document: 10000046963 / 00 03/2008 Summary ABOUT THIS MANUAL... 5 ABBREVIATIONS AND DEFINITIONS... 5 NUMERICAL REPRESENTATION...
CANopen high-level protocol for CAN-bus
CANopen high-level protocol for CAN-bus H. Boterenbrood NIKHEF, Amsterdam March 20, 2000 Contents 1 INTRODUCTION... 2 2 CAL... 2 3 CANOPEN... 3 3.1 CANOPEN OBJECT DICTIONARY... 3 3.2 CANOPEN COMMUNICATION...
38 CANOPEN SLAVE M1. Technical Document. Epec Oy
Technical Document Epec Oy 2 / 57 DOCUMENT VERSION HISTORY Date Notes Updated Sections 10.1 Protection and 11.1 Mounting 23.11.2009 Updated Sections 6.2.1 6200h Write Output 8 bit and 4.16.3 1800h-1807h
An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
DeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
Single Board Controller (pcb controller) CS0015
System manual Single Board Controller (pcb controller) CS0015 System manual single board controller, October 1999 Guarantee This manual was written with the utmost care. However, we cannot assume any guarantee
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Introduction To The CANopen Protocol Version 1.1 Application Note AN-ION-1-1100
Version 1.1 Application Note AN-ION-1-1100 Restrictions Abstract Public Document This application note is a brief introduction to the Higher-Layer CAN Protocol called CANopen. Table of Contents 1 Overview...1
Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0
Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...
Technical Information. Digital Signals. 1 bit. Part 1 Fundamentals
Technical Information Digital Signals 1 1 bit Part 1 Fundamentals t Technical Information Part 1: Fundamentals Part 2: Self-operated Regulators Part 3: Control Valves Part 4: Communication Part 5: Building
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
The Answer to the 14 Most Frequently Asked Modbus Questions
Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in
Hardware Manual RM CANview Ethernet
Hardware Manual RM CANview Ethernet Table of Contents 1 Legal Regulations...3 2 About the Device...4 3 Disposal...4 4 Important Information for Using CANview Ethernet...5 4.1 How to Open the Protection
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section
PRELIMINARY DS2434 Battery Identification Chip FEATURES Provides unique ID number to battery packs PACKAGE OUTLINE Eliminates thermistors by sensing battery temperature on chip DALLAS DS2434 1 2 3 256
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
CANopen communication protocol
CANopen communication protocol 1/43 Document revisions version date description A 10/08 - creation B 07/09 - addition of OIML R76 settings description 2/43 1 INSTALLATION... 5 1.1 Switching to CANopen
User Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
PCAN-ISA. CAN Interface for ISA. User Manual
PCAN-ISA CAN Interface for ISA User Manual Products taken into account Product Name Model Item Number PCAN-ISA Single Channel One CAN channel IPEH-002074 PCAN-ISA Dual Channel Two CAN channels IPEH-002075
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1
Softstarters Type PSTX Fieldbus communication, Built-in Modbus RTU 1SFC132089M0201 April 2015 1SFC132089M0201 1 1 Modbus RTU The Modbus protocol is a fieldbus protocol that provides full control and status
Kvaser Mini PCI Express User s Guide
Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate
HT1632C 32 8 &24 16 LED Driver
328 &216 LED Driver Features Operating voltage: 2.V~5.5V Multiple LED display 32 ROW /8 COM and 2 ROW & 16 COM Integrated display RAM select 32 ROW & 8 COM for 6 display RAM, or select 2 ROW & 16 COM for
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
Operating Manual EX120-SCA1 EX121-SCA1 EX122-SCA1. CANopen SI units
Operating Manual EX120-SCA1 EX121-SCA1 EX122-SCA1 CANopen SI units SMC Pneumatik GmbH Boschring 13 ~ 15 D-63329 Egelsbach Tel.: +49 (0)6103 402 0 Fax: +49 (0)6103 402 139 http://www.smc-pneumatik.de Page
MidiStream. UHF Wireless MIDI System Operating Manual
MidiStream UHF Wireless MIDI System Operating Manual Introduction Congratulations on your purchase of the MidiStream UHF wireless MIDI system. The MidiStream system is very easy to use, but please take
Manual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
PCAN-PC Card CAN Interface for the PC Card Slot. User Manual. Document version 2.3.0 (2015-06-17)
PCAN-PC Card CAN Interface for the PC Card Slot User Manual Document version 2.3.0 (2015-06-17) Products taken into account Product Name Model Part Number PCAN-PC Card Single Channel One CAN channel IPEH-002090
Instruction Manual. Monitor Software for Inclinometer V 3.5
Instruction Manual Monitor Software for Inclinometer V 3.5 Hauert 13, D-44227 Dortmund, Germany 1 of 45 fax: +49-(0)231-9740-20 Table of contents 1 General Information... 3 2 General Software Installation...
CAM-VGA100 User Manual
CAM-VGA100 User Manual Release Note: 1. Jan 28, 2004 official released v1.0 2. Feb 24, 2004 official released v1.1 Fix the definition of verify code Fix the bug of unable jump to power save mode Fix the
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
PCAN-USB CAN Interface for USB. User Manual. Document version 2.3.2 (2015-09-03)
PCAN-USB CAN Interface for USB User Manual Document version 2.3.2 (2015-09-03) Products taken into account Product Name Model Part Number PCAN-USB IPEH-002021 PCAN-USB opto-decoupled Galvanic isolation
CB15/CB155. PROFIBUS Module
CB15/CB155 PROFIBUS Module Contents Warning and Caution Notes 1. OVERVIEW 1.1 Description and Features 1.2 Application on a PROFIBUS Link 2. INSTALLATION 2.1 Installing the Module 2.1.1 CB15 Installation
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Computer Gateway Specification and Technical Data
L Computer Gateway Specification and Technical Data CG03-500 R500 3/96 detergant coffee chocolate Page 2 TDC 3000X Computer Gateway Specification and Technical Data Introduction This publication defines
PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16)
PCAN-MicroMod Universal I/O Module with CAN Interface User Manual Document version 2.1.0 (2014-01-16) Products taken into account Product Name Part number Model PCAN-MicroMod IPEH-002080 with firmware
A RF18 Remote control receiver MODULE
A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject
How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (
FACTORY AUTOMATION MANUAL BM100 BACKUP MODULE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of
Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface
Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface The expert for industrial and automotive communication IXXAT Headquarter US Sales Office IXXAT Automation GmbH IXXAT Inc. Leibnizstr.
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
DS1621 Digital Thermometer and Thermostat
Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent
RS-485 Protocol Manual
RS-485 Protocol Manual Revision: 1.0 January 11, 2000 RS-485 Protocol Guidelines and Description Page i Table of Contents 1.0 COMMUNICATIONS BUS OVERVIEW... 1 2.0 DESIGN GUIDELINES... 1 2.1 Hardware Design
Belimo Gateway MP to Modbus RTU - UK24MOD
Product information UK24MOD MODBUS RTU Belimo Gateway MP to Modbus RTU - UK24MOD Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical
NHD-0420D3Z-FL-GBW-V3
NHD-0420D3Z-FL-GBW-V3 Serial Liquid Crystal Display Module NHD- Newhaven Display 0420-4 Lines x 20 Characters D3Z- Model F- Transflective L- Yellow/Green LED Backlight G- STN-Gray B- 6:00 Optimal View
RS - SPM. Serial parallel translator module
ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: [email protected] RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject
DMX2PWM 9 Channel Dimmer Setup Manual
DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
Site Master S251B Antenna and Cable Analyzer
Site Master S251B Antenna and Cable Analyzer Programming Manual Hand-Held Tester For Antennas, Transmission Lines And Other RF Components WARRANTY The Anritsu product(s) listed on the title page is (are)
udrive-usd-g1 Embedded DOS micro-drive Module Data Sheet
4D SYSTEMS udrie-usd-g1 Embedded DOS micro-drive Module Document Date: 2nd April 2009 Document Revision: 2.0 Page 1 of 9 udrie-usd-g1 Embedded DOS micro-drive 4D SYSTEMS Description Features The is an
CAN@net II Intelligent PC/CAN Interface. Manual
CAN@net II Intelligent PC/CAN Interface Manual IXXAT Automation GmbH Leibnizstr. 15 D-88250 Weingarten Tel.: +49 (0)7 51 / 5 61 46-0 Fax: +49 (0)7 51 / 5 61 46-29 Internet: www.ixxat.de e-mail: [email protected]
Application Note. EtherCAT Master Architecture. Applicable Products: Yaskawa Servodrives with CANopen over EtherCAT
Application Note EtherCAT Master Architecture Applicable Products: Yaskawa Servodrives with CANopen over EtherCAT Yaskawa America, Inc. Drives & Motion Division 2014 March 5, 2015 Page 1 of 18 Table of
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Application te Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Abstract This
EXTERNAL DIMENSIONS AND PARTS
FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special
BNI IOL-709-000-K006 BNI IOL-710-000-K006. IO-Link Sensor-Hub analog User s Guide
BNI IOL-709-000-K006 BNI IOL-710-000-K006 IO-Link Sensor-Hub analog User s Guide Inhalt 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Positioning Controllers. Communication Guide. Document ID: rel4054
Communication Guide EPOS2 Positioning Controllers Edition April 2013 Positioning Controllers Communication Guide Document ID: rel4054 maxon motor ag Brünigstrasse 220 P.O.Box 263 CH-6072 Sachseln Phone
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
PLUTO Safety-PLC. Manual Absolute Encoders
PLUTO Safety-PLC Manual Absolute Encoders English v6a 2TLC172006M0206_A Table of contents: 1 General... 3 1.1 Reaction time... 3 1.2 Safety parameters... 3 2 Electrical... 4 2.1 Separation with Gateway
Instruction Manual Service Program ULTRA-PROG-IR
Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...
Single channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
Road Vehicles - Diagnostic Systems
SSF 14230 Road Vehicles - Diagnostic Systems Keyword Protocol 2000 - Part 1 - Physical Layer Swedish Implementation Standard Document: SSF 14230-1 Status: Issue 3 Date: October 22, 1997 This document is
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
MEMOBUS/Modbus Communications
2 2.1 MEMOBUS/MODBUS CONFIGURATION............260 2.2 COMMUNICATION SPECIFICATIONS..............261 2.3 COMMUNICATION TERMINAL RESISTANCE........262 2.4 CONNECTING A PLC...........................263 2.5
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
DS1621 Digital Thermometer and Thermostat
www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Manual. VE.Bus to NMEA 2000 interface
Manual EN VE.Bus to NMEA 2000 interface Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For
Documentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
FPGA INTEGRATION MANUAL SATURN-SIL 2 MODULES. Dictionary Code. Edition 01. Revision 00. Number of pages 18
Dictionary Code D741 Edition 01 Revision 00 Number of pages 18 State Approved SATURN-SIL 2 MODULES FPGA CLEARSY : SOCIETE PAR ACTIONS SIMPLIFIEE AU CAPITAL DE 266 880 - R.C.S. AIX-EN-PROVENCE - CODE SIRET
Original instructions. PLUTO Gateway. User Manual. PROFIBUS GATE-P1/P2 DeviceNet GATE-D1/D2 CANopen GATE-C1/C2 Ethernet GATE-E1/E2
Original instructions PLUTO User Manual PROFIBUS GATE-P1/P2 DeviceNet GATE-D1/D2 CANopen GATE-C1/C2 Ethernet GATE-E1/E2 English v10e 2TLC172009M0210_E Revision history: Version Date Change 1A 2006-04-20
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Flarm LED indicator. Version 1.1
Flarm LED indicator Version 1.1 LXNAV d.o.o. Kidričeva 24a, 3000 Celje, Slovenia tel +386 592 33 400 fax +386 599 33 522 [email protected] www.lxnav.com 1 Important Notices 3 1.1 Limited Warranty 3 2 Packing