A PRACTICAL GUIDE TO THE WIRING REGULATIONS
|
|
|
- Evan Young
- 9 years ago
- Views:
Transcription
1 A PRACTICAL GUIDE TO THE WIRING REGULATIONS 17 th EDITION IEE WIRING REGULATIONS (BS 7671:2008) Fourth Edition Eur Ing Geoffrey Stokes BSc (Hons), CEng, FIEE, FCIBSE Eur Ing John Bradley BSc, CEng, MIEE, FCIBSE A John Wiley and Sons, Ltd., Publication
2
3 A PRACTICAL GUIDE TO THE WIRING REGULATIONS
4
5 A PRACTICAL GUIDE TO THE WIRING REGULATIONS 17 th EDITION IEE WIRING REGULATIONS (BS 7671:2008) Fourth Edition Eur Ing Geoffrey Stokes BSc (Hons), CEng, FIEE, FCIBSE Eur Ing John Bradley BSc, CEng, MIEE, FCIBSE A John Wiley and Sons, Ltd., Publication
6 Geoffrey Stokes 1994, 1999, 2002 Geoffrey Stokes and John Bradley 2009 Blackwell Publishing was acquired by JohnWiley & Sons in February Blackwell s publishing programme has been merged with Wiley s global Scientific, Technical, and Medical business to form Wiley-Blackwell. Registered office JohnWiley & Sons Ltd, The Atrium, Southern Gate, Chichester,West Sussex, PO19 8SQ, United Kingdom Editorial offices 9600 Garsington Road, Oxford, OX4 2DQ, United Kingdom 2121 State Avenue, Ames, Iowa , USA For details of our global editorial offices, for customer services and for information about how to apply for permission to reuse the copyright material in this book please see our website at The right of the author to be identified as the author of this work has been asserted in accordance with the Copyright, Designs and Patents Act All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, except as permitted by the UK Copyright, Designs and Patents Act 1988, without the prior permission of the publisher. Wiley also publishes its books in a variety of electronic formats. Some content that appears in print may not be available in electronic books. Designations used by companies to distinguish their products are often claimed as trademarks. All brand names and product names used in this book are trade names, servicemarks, trademarks or registered trademarks of their respective owners. The publisher is not associated with any product or vendor mentioned in this book. This publication is designed to provide accurate and authoritative information in regard to the subject matter covered. It is sold on the understanding that the publisher is not engaged in rendering professional services. If professional advice or other expert assistance is required, the services of a competent professional should be sought. First edition published 1994 Second edition published 1999 Third edition published 2002 Fourth edition published 2009 Library of Congress Cataloging-in-Publication Data Stokes, Geoffrey, CEng. A practical guide to the wiring regulations/geoffrey Stokes. 4th ed. p.cm. Includes bibliographical references and index. ISBN (cloth) 1. Electric wiring Insurance requirements Handbooks, manuals, etc. 2. Electric wiring, Interior Handbooks, manuals, etc. 3. Electric apparatus and appliances Installation Great Britain Handbooks, manuals, etc. I. Bradley, John. II. Title. TK3275.S dc A catalogue record for this book is available from the British Library ISBN Typeset in 10/12 Times by Laserwords Private Limited, Chennai, India Printed and bound in Great Britain by TJ International, Padstow, Cornwall For further information on Blackwell Science, visit our website:
7 Contents About the authors Preface to the Fourth Edition Acknowledgements Notation xvii xix xxi xxiii 1 Plan and terminology of BS 7671:2008 and supporting publications Plan of BS 7671: Terminology of BS 7671: Supporting publications 6 2 Electricity, the law, standards and codes of practice General Electricity: the hazards The law Electricity Safety, Quality and Continuity Regulations The Electricity at Work Regulations 1989 (EWR) Standards and codes of practice The IEE Wiring Regulations: BS Electric signs and high-voltage luminous-discharge-tube installations: BS 559 and BS EN Emergency lighting: BS Electrical equipment for explosive gas atmospheres: BS EN Electrical equipment for use in the presence of combustible dust: BS EN and BS EN Electrical installations in opencast mines and quarries: BS Fire detection and alarm systems for buildings: BS Telecommunications systems: BS Electric surface heating: BS Lightning protection: BS EN Lift installations: BS 5655 and BS EN
8 vi Contents Equipment 15 3 Scope, object and fundamental principles General Scope General Exclusions from the scope Equipment Relationship with statutory authorities Installations in premises subjected to licensing Object and effects General New materials and inventions Fundamental principles General Electric shock: basic protection Electric shock: fault protection Protection against thermal effects Protection against overcurrent Protection against fault current Protection against voltage disturbances and measures against electromagnetic influences Protection against supply interruption Additions and alterations to an installation Design Selection of electrical equipment Erection, initial verification of electrical installations, and periodic inspection and testing 26 4 Assessment of general characteristics General Loading, maximum demand and diversity General Lighting: loading and diversity Heating: loading and diversity Cookers: loading and diversity Water heaters: loading and diversity Motors: loading and diversity Stationary equipment: loading and diversity Conventional circuits: loading and diversity Socket-outlet circuits other than conventional circuits: loading and diversity Arrangement of live conductors and type of earthing Arrangement of live conductors Type of earthing 35
9 Contents vii 4.4 Nature of supply General Voltage The nature of current and frequency Prospective short-circuit current External earth fault loop impedance Suitability of supply Type and rating of overcurrent device at the origin Supplies for safety services and standby purposes Installation circuit arrangements External influences Compatibility Maintainability 46 5 Protection against electric shock General Provisions for basic protection General Basic insulation of live parts Barriers or enclosures Protective measure: automatic disconnection of supply General Basic protection in ADS General requirements for fault protection in ADS Fault protection in ADS: for TN systems Fault protection in ADS: for TT systems Fault protection in ADS: for IT systems Functional extra-low voltage Reduced low-voltage systems Protective measure: double or reinforced insulation Protective measure: electrical separation Protective measure: extra-low voltage provided by SELV or PELV Additional protection Obstacles and placing out of reach Obstacles Protection by placing out of reach Protective measures for application only where the installation is controlled or under the supervision of skilled or instructed persons Non-conducting location Protection by earth-free local equipotential bonding Electrical separation for the supply to more than one item of current-using equipment 86 6 Protection against thermal effects General 89
10 viii Contents 6.2 Fire caused by electrical equipment Surface temperature Arcs, sparks and high-temperature particles Position of equipment embodying heat sources Flammable liquids Construction of enclosures Live conductors Precautions where particular risks of danger of fire exist General Conditions for evacuation in an emergency Locations with risks of fire due to the nature of processed or stored materials Combustible constructional materials Fire-propagating structures Selection and erection of installations in locations of national, commercial, industrial or public significance Burns Protection against overcurrent, undervoltage and overvoltage General Nature of protective devices Protection against overload General Protection against overload: motors Ring final circuits Protection against fault current Determination of prospective fault current General Calculation of inductive reactance Evaluation of k for different temperatures Calculation of impedance of steel enclosures Resistance and inductive reactance values Temperature adjustments to resistance values Line-to-neutral short-circuits Line-to-line short-circuits Three-phase short-circuit Line-to-earth faults Fault current at the origin of an installation Characteristics of protective devices Overcurrent protection of conductors in parallel Coordination of overload and fault current protection Protection according to the nature of circuits and distribution systems Protection against undervoltage Protection against overvoltage General 137
11 Contents ix Temporary overvoltages due to earth faults in the high-voltage system or faults in the low-voltage system Overvoltages of atmospheric origin or due to switching Isolation and switching General Main switch Isolation Switching off for mechanical maintenance Emergency switching and other forms of switching for safety General The firefighter s switch Emergency stopping Functional switching Identification and notices Equipment selection: common rules General Compliance with standards Operational conditions, external influences and accessibility Identification and notices Mutual detrimental influences Compatibility Operation and maintenance manual Wiring systems Wiring systems Wiring systems: general Fire performance of wiring systems External influences External influences: general Temperature Water Solid foreign bodies Corrosive and polluting substances Mechanical damage: general Mechanical damage: concealed and buried cables Damage by fauna, flora and mould growth Building design considerations Solar radiation Proximity to other services: general Proximity of electrical wiring systems to other electrical systems Proximity of electrical wiring systems to communications cables Proximity of electrical wiring systems to nonelectrical systems Methods of installation of cables 205
12 x Contents General Current-carrying capacities, cross-sectional area of conductors and conductor operating temperatures Voltage drop Grouping Resistances of copper conductors Electrical connections Cable supports and cable management systems General Maximum cable support spacings Overhead cables between buildings Supports for conduits Minimum bending radii of cables Maximum cable trunking support spacings Other cable management systems Minimizing the risk of fire Electromagnetic and electromechanical effects Conduit and trunking cable capacities Conduit capacities Trunking capacities Maintainability Switchgear, protective devices and other equipment Switchgear and protective devices: general Switchgear and controlgear Switchgear and controlgear: general Switchgear and controlgear: forms of assembly Selection of devices for overload and fault current protection: general Overcurrent protective devices Fuses: general Semi-enclosed fuses to BS High breaking capacity fuses to BS High breaking capacity fuses to BS Cartridge fuses to BS Miniature circuit-breakers to BS 3871 and BS EN Moulded case circuit-breakers to BS EN Residual current devices Residual current devices: general Residual current devices: principles of operation Residual current monitors Identification of overcurrent protective devices Discrimination Discrimination: general Discrimination: high breaking capacity high breaking capacity fuses 272
13 Contents xi Discrimination: miniature circuit-breakers miniature circuit-breakers Discrimination: miniature circuit-breakers fuse Discrimination: residual current devices Other equipment Accessories Luminaires and lighting points Heaters for liquids and other substances, including water Heating conductors and electric surface heating systems Transformers Rotating machines Protective conductors, earthing and equipotential bonding Protective conductors Protective conductors: general Protective conductors: types Protective conductors: thermal withstand Protective conductors: sizes Protective conductors: for combined protective and functional purposes Protective conductors: electrical continuity Protective conductors: formed by steel conduit, trunking, etc Protective conductors: mineral-insulated cables Protective conductors of ring final circuits Protective conductors: armouring Protective conductors: clean earths Protective conductors: proving and monitoring Earthing Earthing: general Earthing: responsibilities Earthing: connection to Earth and system arrangements Earthing conductors Earthing electrodes Main earthing terminals Earthing: accessories and other equipment Earthing requirements for the installation of equipment having high protective conductor currents General Additional requirements for earthing of equipment in TN and TT systems Minimum cross-sectional area of protective conductors of final and distribution circuits Residual current device compatibility IT systems Protective bonding Main protective bonding 318
14 xii Contents Supplementary bonding Bonding clamps Specialized installations General Emergency lighting Fire detection and alarm systems Petrol filling stations and liquid petroleum gas stations Installations in dusty environments Installations in underground and multistorey car parks, etc Installations in multi-occupancy blocks of flats Installations in Section 20 buildings Installations in churches Installations in thatched properties Extra-low voltage lighting Outdoor lighting installations, highway power supplies and street furniture General Protection against electric shock Isolation and switching Cable installation and identification Security lighting Welding equipment Entertainers equipment Generator sets Safety services Safety services: general Common sources Parallel and nonparallel sources Circuit and equipment requirements Protection against overcurrent and electric shock under fault conditions The smaller installation Scope The IEE On-Site Guide and the NICEIC Domestic Electrical Installation Guide User s requirements Wiring systems Electricity distributor s requirements Assessment of supply characteristics Meter tails System earthing arrangements Main protective bonding Minimum cross-sectional area of earthing and main protective bonding conductors 360
15 Contents xiii Supplementary bonding Devices for protection against overcurrent and for fault protection Devices for isolation and switching Final circuit design Remote buildings Minimum number of socket-outlets in domestic premises Modifications to existing installations Inspection, testing, verification and certification of the smaller installation Special installations and locations General Locations containing a bath or shower General Zonal arrangements Degrees of ingress protection Equipment permitted in and outside the various zones Electric shock Supplementary bonding Shaver supply units and socket-outlets Mobile and nonfixed current-using equipment Electric heating embedded in the floor Other equipment Swimming pools and other basins General Additional requirements relating to electric shock Additional requirements relating to selection and erection of equipment Rooms and cabins containing sauna heaters General Construction-site installations General Protection against electric shock Selection of equipment Isolation and switching Agricultural and horticultural premises General Protection against electric shock Fire and harmful thermal effects Selection of equipment Automatic life support for high-density livestock rearing RCDs in series Conducting locations with restricted movement General Protection against electric shock Electrical installations in caravan/camping parks and similar locations General 422
16 xiv Contents Requirements for safety Equipment: selection and erection Typical caravan park distribution layout Marinas and similar locations General Protection against electric shock External influences Equipment: selection and erection Exhibition shows and stands General Definitions Protection against electric shock and protection against fire Equipment: selection and erection Solar photovoltaic power supply systems General Definitions Earthing a live conductor on the d.c. side Protection against electric shock, overcurrent and electromagnetic interference Equipment: selection and erection Mobile or transportable units General Source of supply Protection against electric shock Equipment: selection and erection Electrical installations in caravans and motor caravans General Requirements for safety Wiring systems Main isolating switch, caravan inlets and connection leads Luminaires and accessories Annex A of Section 721: guidance on 12 V d.c. installations Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses General Electrical supplies and protection against electric shock Motors: protection against excess temperature Equipment: selection and erection Floor and ceiling heating systems General Heating units Protection against electric shock Protection against harmful thermal effects Heating-free areas Wiring systems Identification and notices 457
17 Contents xv 17 Inspection, testing, certification and reporting Inspection, testing, certification and reporting: general Test instruments General Insulation test instruments Continuity test instruments Earth loop impedance test instruments Applied voltage test instruments Earth electrode test instruments Residual current device test instruments Voltage indication Phase sequence test instruments Safety in electrical testing Test methods General Insulation tests Barriers and enclosures Non-conducting location tests Polarity tests Continuity tests Earth loop impedance and prospective fault current tests Applied voltage tests Earth electrode tests Residual current device tests Protection by SELV, PELV or electrical separation Verification of phase sequence Functional testing Verification of voltage drop Initial verification General Inspection Testing Initial certification: general Initial certification: caravans Initial certification: minor works Periodic inspection and testing General Intervals between periodic inspection and testing Approximate age of an installation Periodic inspection and testing Reporting Alterations and additions General Inspection Testing Certification 534
18 xvi Contents 17.8 Inspection, testing and certification of specialized installations Fire detection and alarm systems in buildings Emergency lighting Petrol filling stations 535 Appendix Standards to which reference has been made 537 Bibliography 545 Index of figures 547 Index of tables 551 Index of regulation numbers 557 Subject index 579
19 About the authors Geoffrey Stokes BSc (Hons), CEng, FIEE, FCIBSE was the author of the first three editions of this Guide. For many years he was the Principal Engineer of the National Inspection Council for Electrical Installation Contracting. Before that he was Technical Regulations Manager at the Institution of Electrical Engineers, which is now the Institution of Engineering and Technology (IET). Geoffrey has served for many years on many BSI, CENELEC and IEC Technical Committees and now represents the IET on the joint IET/BSI Committee JPEL/64, which is responsible for the technical content of the Wiring Regulations (BS 7671). He is also a Member of the IET s Wiring Regulations Policy Committee. Geoffrey left the National Inspection Council in 2005 to set up a new electrical safety consultancy (Benchmark Electrical Safety Technology Ltd) and to assist in the development work of a new innovative revolution in automated electrical installation testing technology (Test Marshal). John Bradley BSc, CEng, MIEE, FCIBSE updated this Guide to the 17th Edition of the Wiring Regulations. He is the Principal Engineer at the Electrical Safety Council (formerly the National Inspection Council for Electrical Installation Contracting), where he has special responsibilities for the Council s technical standards and publications. John has also worked in electrical contracting and as a consulting engineer, putting the requirements of the Wiring Regulations into practice. He serves on a number of CENELEC and IEC technical committees and on the joint IET/BSI Committee JPEL/64 which is responsible for the technical content of the Wiring Regulations (BS 7671) and European and international standards for electrical installations. John is the Chairman of Panel C of JPEL/64 (protection against electric shock, and isolation and switching).
20
21 Preface to the Fourth Edition This fourth edition of A Practical Guide to the Wiring Regulations takes account of the requirements of BS 7671:2008 Requirements for Electrical Installations (IEE Wiring Regulations Seventeenth Edition). BS 7671:2008 was issued on 1 January 2008 and came into effect on 1 July It replaces BS 7671:2001 (IEE Wiring Regulations Sixteenth Edition) as the national standard for electrical installation work, and its requirements are to be complied within all electrical installation work designed after 30 June The content of BS 7671:2008 has undergone extensive changes and additions compared with that of BS 7671:2001. The numbering of the regulations has also been revised to follow the pattern and corresponding references of International Electrotechnical Commission (IEC) Standard Account has been taken in BS 7671:2008 of the technical intent of a significant number of revised and new CENELEC harmonization documents (HDs). Indeed, of the 28 HDs listed in the preface of BS 7671:2008, 17 are revised compared with the versions used in BS 7671:2001, as finally amended, and seven are newly introduced to BS The revised HDs have led to changes in, amongst other things, the various protective measures specified in Part 4 of BS 7671 and the requirements for special installations or locations. Not the least of the changes are those affecting the general requirements for protection against electric shock, which have been restructured and are subject to new terminology. Another notable change is that it is now permitted to install general-purpose socket-outlets in locations containing a bath or shower, provided these outlets are at least 3 m horizontally outside the boundary of zone 1 and the circuit supplying them is provided with additional protection by an RCD having specified characteristics (as must be all the circuits of the special location). The newly introduced HDs have led to the addition of new sections in BS 7671 relating to: marinas and similar locations; exhibitions, shows and stands; solar photovoltaic power supply systems; mobile or transportable units; caravans and motor caravans (previously covered in Section 608 of BS 7671:2001); temporary installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses; and floor and ceiling heating systems. While many changes have been associated with CENELEC HDs, a number of modifications made have been initiated in the United Kingdom. These primarily relate to cables concealed in walls and/or partitions in installations that are not intended to be under the supervision of a skilled or instructed person. In many cases, such cables are now required
22 xx Preface to the Fourth Edition to be provided with additional protection by an RCD having specified characteristics, unless other specified protective provisions are employed. In their professional experience the authors of this Guide have been asked, and attempted to answer, numerous questions over the years relating to the regulatory requirements and their implementation. While most practitioners will recognise where a proposed solution will not, or does not, meet the requirements, many find it difficult to attribute a precise regulation number to the deficiencies they believe to exist or to decide what action to take in solving the problem. This is not surprising since the subject of electrical installations is vast and complex. Those that believe that all issues are crystal clear (or black and white) and that there is only one possible solution to a design problem are deluding themselves. As there are many ways of killing a cat (besides electrocution) so too are there many design and installation options so long as the basic constraints are met. An attempt has been made in this Guide to make life a little easier and topics are addressed with the pertinent Regulation numbers listed where appropriate. However, the Guide will be most useful to those who have at least a working knowledge of earlier editions of the National Standard. This Guide is not intended for use by the DIY enthusiast unless, of course, he or she happens to be competent in this field. Where considered necessary by the authors, some background guidance is given together with worked examples embodied in the text at the appropriate place. It is hoped that this Guide will serve both as a useful aid to designers, installers and verifiers of electrical installations and to others not directly professionals in the industry but who have an interest in the safety aspects of electrical installations perhaps as duty holders as defined by the Electricity at Work Regulations It is also expected that it will be of use to those students of the industry who are endeavouring to come to grips with all the many facets of electrical safety. Extensive use has been made of tables which draw together the various relevant Regulations and options. Where appropriate, tables have also been employed as check lists for reference for those who find such listings useful in their day-to-day activities. Similarly, numerous figures have been used to more clearly identify specific points that the authors have thought worthy of mention. No single book can ever cover all the aspects of this topic and the authors have had to take the view that this Guide should include guidance on the issues that are more frequently encountered, leaving aside some of the more esoteric aspects. Inspection, testing, verification, certification and reporting come in for special attention as the authors believe many electrical contractors would welcome some guidance in this respect. The views expressed here are the authors own and should not be regarded as coinciding with those of any authoritative body, though the authors believe they do not differ materially. Geoffrey Stokes and John Bradley
23 Acknowledgements Geoffrey Stokes acknowledges with gratitude the initial encouragement and subsequent support given to him by his dear friend and former colleague Brian D. Jenkins, who also reviewed the final draft of the First Edition of this Guide. Geoffrey also wishes to record the considerable assistance given to him by his friends in the industry and, in particular, his former NICEIC colleagues both at Head Office and three Inspecting Engineers in the field. He particularly wishes to acknowledge with gratitude the contributions made, by way of constructive criticism and comment on the drafts, by: Bill Holdway, IEng, MIEIE, NICEIC Inspecting Engineer, Staffordshire; Brian D. Jenkins, BSc, CEng, FIEE; Keith Morriss, BSc, CEng, MIEE, Technical Director, AVO International Ltd; Terry Morrow, IEng, MIEIE, NICEIC Inspecting Engineer, Northern Ireland; Nick Piper, NICEIC Inspecting Engineer, West Midlands; Ted Smithson, BSc, CEng, MIEE, Engineering Manager, AVO: Megger Instruments Ltd. John Bradley acknowledges the encouragement and support given to him by Geoffrey Stokes in the considerable task of updating this Guide to align with the requirements of the Seventeenth Edition of the IEE Wiring Regulations. John also records his appreciation of his employer, The Electrical Safety Council, for its support and permission to reproduce certain copyright material. He also wishes to acknowledge with gratitude the assistance given to him by his colleague Martyn Allen, BEng Hons, CEng, MIET, Senior Engineer at The Electrical Safety Council, who reviewed the final draft of the Fourth Edition of this Guide and provided many helpful comments. Extracts from British Standards are reproduced with the permission of BSI. Complete copies can be obtained from BSI Shop Support Services (Hardcopy support: +44 (0) ; Softcopy support: +44 (0) ; Fax: +44 (0) ; Grateful acknowledgement is made to the Institution of Engineering and Technology for its permission to reproduce copyright material from the Seventeenth Edition of the IEE Wiring Regulations and related Guidance Notes.
24
25 Notation Acronyms and abbreviations BCMC British Cable Makers Confederation BS British Standard BS EN Harmonized European Standard BSI British Standards Institution CENELEC Comité Européen de Normalisation Electrotechnique (European Committee for Electrotechnical Standardization) CIBSE Chartered Institution of Building Services Engineers CONSAC Concentric Solid Aluminium Core (cable) ccc current-carrying capacity cpc circuit protective conductor csa cross-sectional area DCL device for connecting a luminaire DoE Department of Environment (now incorporated into Department for Environment, Food and Rural Affairs (Defra)) DOL direct-on-line DP double-pole ED electricity distributor ADS automatic disconnection of supply EIILC Electrical Installation Industry Liaison Committee EL emergency lighting ELV extra-low voltage ESC The Electrical Safety Council ESQCR Electricity Safety, Quality and Continuity Regulations 2002, as amended ESR Electricity Supply Regulations 1988, as amended EWR Electricity at Work Regulations 1989 FA fire alarm FELV functional extra-low voltage (see definition in the Wiring Regulations) HBC high breaking capacity HD harmonized document HSE Health and Safety Executive HV high voltage ICEL Industry Committee for Emergency Lighting IEC International Electrotechnical Commission IEE Institution of Electrical Engineers IET Institution of Engineering and Technology
26 xxiv Notation L LPG LSC LSHF LV M MCB MCCB MET MICC NHBC NICEIC NM PELV PEN PME PRCD PVC RCD RCCB RCBO SELV SP SP&N TDM TP TP&N TTA XLPE 4P Variables α 20 B C a C c C g C i cos φ C t D e I a I b I d I n I F I FLC line liquefied petroleum gas luminaire supporting coupler low smoke, halogen free low voltage maintained (emergency lighting) miniature circuit-breaker moulded case circuit-breaker main earthing terminal mineral-insulated copper cable National House-Building Council NICEIC Group Limited Nonmaintained (emergency lighting) protective extra-low voltage (see definition in the Wiring Regulations) protective earth and neutral (conductor) protective multiple earthing portable residual current device polyvinyl chloride residual current device residual current circuit-breaker combined MCB and RCD separated extra-low voltage (see definition in the Wiring Regulations) single-pole single-pole and neutral time-division-multiplexing triple-pole triple-pole and neutral type-tested assembly cross-linked polyethylene or ethylene propylene rubber insulation four-pole resistance/temperature coefficient at 20 C reciprocal of temperature coefficient of resistivity rating factor for ambient temperature rating factor for the type of protective device or installation condition rating factor for grouping of conductors rating factor for conductors embedded in thermal insulated materials power factor factor for the operating temperature of the conductor cable diameter (mm) current causing automatic disconnection within stated time (A) design current of circuit (A) first-fault fault current of circuit (IT systems) (A) rated residual current of an RCD (A or ma) fault current (both short-circuit and earth fault depending on the context in which it is used) (A) full-load current (A)
27 Notation xxv I inst current causing instantaneous (within 100 ms) operation of protective device (A) I L earth-leakage current (ma) I L(T) total earth-leakage current (ma or A) I n rated current of protective device (A) I pf prospective fault current (A) I t tabulated current-carrying capacity (A) I t(min) minimum tabulated current-carrying capacity required (A) I 2 t energy let-through (A 2 s) I 2 t (pa) pre-arcing energy let-through (A 2 s) I 2 t (t) total energy let-through (A 2 s) I (sec) transformer secondary current (A) I z effective current-carrying capacity (A) I 2 current causing effective operation of protective device on overload (A) j imaginary part of a complex variable (j = 1) k a constant attributed to a particular conductor L, l length (m) ln log to the base e π pi, geometric constant (3.1416) P active power (W or kw) diameter (mm) φ phase angle Q reactive power (VA r or kva r ) Q c volumetric heat capacity of a conductor (J/( Cmm 3 )) Q 20 electrical resistivity of conductor material at 20 C ( mm) ρ resistivity ( m) R resistance (generally) ( ) R A sum of the resistances of the installation earth electrode and protective conductor ( ) R n circuit neutral conductor resistance ( ) R t conductor resistance at temperature t( ) R 1 circuit line conductor resistance ( ) R 2 circuit protective conductor resistance ( ) R 20 conductor resistance at temperature of 20 C ( ) S apparent power (VA or kva) S conductor cross-sectional area (mm 2 ) S p protective conductor cross-sectional area (mm 2 ) θ i initial temperature of conductor ( C) θ f final temperature of conductor ( C) t temperature ( C) t time (s) T d time delay (s) t p maximum permitted operating temperature ( C) U n nominal voltage (V) U o nominal voltage to Earth (V) U t touch voltage (V) V d voltage drop (V or mv) resistive voltage drop (V or mv) V d(r)
28 xxvi Notation V d(x) V FL V L L V NL Z dpc Z e Z L Z L N Z pu Z 1 Z 2 Z s Zs Z s(max) X X L X C reactive voltage drop (V or mv) full-load voltage (V) line-to-line voltage (V) no-load voltage (V) impedance of distribution circuit protective conductor ( ) external line earth loop impedance ( ) line impedance ( ) line neutral impedance ( ) per unit impedance impedance of circuit line conductor ( ) impedance of circuit protective conductor ( ) line earth fault loop impedance ( ) line earth fault loop impedance (IT systems) ( ) maximum permitted line earth fault loop impedance ( ) reactance ( ) inductive reactance ( ) capacitive reactance ( )
29 1 Plan and terminology of BS 7671:2008 and supporting publications 1.1 Plan of BS 7671:2008 BS 7671:2008 is based, as was the 2001 version, on the International Electrotechnical Commission s (IEC s) publication 60364, the international rules for electrical installations. The pattern of BS 7671:2008 uses a similar logical plan to that of earlier versions, although there are some minor changes to detail. Table 1.1 illustrates the plan and shows the main routes through the various parts to assimilate all the necessary requirements for the electrical design. The routes shown should not be regarded as exhaustive or the only feasible routes; indeed, reference to other parts and sections, on an iterative basis, will always be necessary. Although the plan of BS 7671 does follow a logical sequence, it may not follow the generally accepted sequence undertaken by designers. For example, a designer s sequence may take the form of: assessment of general characteristics (Part 3); assessment of the number and types of circuit (Part 3, Section 314); selection of wiring system(s) (Chapter 52); assessments of design currents, including taking account of diversity, where appropriate, and any special operating conditions (Sections 311 and 433); assessment of environmental conditions, including external influences (Section 522); selection of overcurrent protective devices (Section 533); selection of devices for fault protection by automatic disconnection of supply (Regulation Groups ); determination of current-carrying capacities (Section 523); assessment of voltage drop (Section 525); assessment of isolation and switching requirements (Section 537); A Practical Guide to The Wiring Regulations: 17th Edition IEE Wiring Regulations (BS 7671:2008) Fourth Edition Geoffrey Stokes and John Bradley Geoffrey Stokes and John Bradley. Published by John Wiley & Sons, Ltd
30 2 A Practical Guide to The Wiring Regulations Table 1.1 Plan of BS 7671:2008 PART 1: SCOPE OBJECT AND FUNDAMENTAL REQUIREMENTS FOR SAFETY PART 2: DEFINITIONS PART 3: PART 4: PART 5: PART 6: PART 7: APPENDICES ASSESSMENT OF GENERAL CHAR- ACTERISTICS PROTECTION FOR SAFETY SELECTION AND ERECTION OF EQUIPMENT INSPECTION AND TESTING SPECIAL INSTALLATIONS OR LOCATIONS Chapter 31: Chapter 41: Chapter 51: Chapter 61: Section 700 : Appendix 1: Purposes, supplies and structure Protection against electric shock Common rules Initial verification General British Standards to which reference is made in the regulations Section 701 : Appendix 2: Locations containing a Statutory regulations and bath tub or shower basin associated memoranda Chapter 32: Chapter 42: Chapter 52: Chapter 62: Section 702 : Appendix 3: Classification of external influences Protection against thermal effects Selection and erection of wiring systems Periodic inspection and testing Swimming pools and other basins Time/current characteristics of overcurrent protective devices and residual current devices Section 703 : Appendix 4: Rooms and cabins Current-carrying capacity containing sauna heaters and voltage drop for cables and flexible cords
31 Plan and terminology of BS 7671:2008 and supporting publications 3 Chapter 33: Chapter 43: Chapter 53: Chapter 63: Section 704 : Appendix 5: Compatibility Protection against overcurrent Protection, isolation, switching, control and monitoring Certification and reporting Construction and demolition site installations Classification of external influences Section 705 : Appendix 6: Agricultural and Model forms of horticultural premises certification and reporting Chapter 34: Chapter 44: Chapter 54: Section 706 : Appendix 7: Maintainability Protection against voltage disturbances and electromagnetic disturbances Earthing arrangements and protective conductors Conducting locations with restricted movement Harmonized cable core colours Section 708 : Appendix 8: Electrical Current-carrying capacity installations in of busbar trunking and camping/caravanning powertrack systems parks and similar locations Chapter 35: Chapter 55: Section 709 : Appendix 9: Safety Services Other equipment Marinas and similar locations Definitions Multiple source, d.c. and other systems Section 711 : Appendix 10: Exhibitions, shows and Protection of conductors stands in parallel against overcurrent (continued overleaf)
32 4 A Practical Guide to The Wiring Regulations Table 1.1 (continued) Chapter 36: Chapter 56: Section 712 : Appendix 11: Continuity of Service Safety services Solar voltaic (pc) power supply systems Effect of harmonic currents on balanced three-phase systems Section 717 : Appendix 12: Mobile or transportable Voltage drop in units consumers installations Section 721 : Appendix 13: Electrical installations in Methods of measuring caravans and motor the insulation caravans resistance/impedance of floors and walls to earth or to the protective conductor system Section 740 : Appendix 14: Temporary electrical Measurement of fault installations for loop impedance: structures, amusement consideration of the devices and booths at increase of resistance of fairgrounds, amusement conductors with increase parks and circuses of temperature Section 753 : Appendix 15: Floor and ceiling heating Ring final and radial systems final circuit arrangements, Regulation 433.1
33 Plan and terminology of BS 7671:2008 and supporting publications 5 Part 5 Chapter 3 Section 4 Group 2 Individual identifying number 3 Further individual identifying number (where present) 1 Individual number for a regulation group a Individual number for a regulation b Individual number for a regulation b a May also be used for a regulation. b May also be used for a regulation subgroup. Figure 1.1 Regulation numbering system consideration of the earthing and protective bonding requirements (Chapter 54). It can be seen that the example of the design process given above does not follow the layout of BS 7671, and even the example shown is an oversimplification of the real process. However, the designer familiar with the earlier versions would have no difficulty in applying BS 7671:2008. In essence, the designing process will inevitably mean numerous references back and forth throughout BS 7671, and only experience will reduce the iterative procedure. The numbering system in BS 7671 is in line with the IEC and CENELEC (Comité Européen de Normalisation Electrotechnique) numbering system. It uses regulation numbers with mainly one, two or three decimal points (e.g , and ), although numbers with up to five decimal points are used in Part 7. Additionally, a group of associated regulations is covered by a side heading such as RCDs in a TN system. Similarly, a subgroup of associated regulations is covered by a side heading such as Fuses. Figure 1.1 illustrates how the numbers are formulated and this applies to all parts except Part 7. In Part 7, sections take the place of chapters, and in the regulation numbers, the number appearing after the section number generally refers to the corresponding chapter, section or regulation in Parts 1 6. BS 7671 is less a design code of practice than a standard for safe practice and is more of a framework document like the emergent CENELEC Harmonized Documents. Part 6 addresses inspection and testing in a format with individual chapters allocated to initial verification, periodic inspection and testing, and certification and reporting. Part 7 Special Installations or Locations is based on, but not identical to, IEC publication 60364, Part Terminology of BS 7671:2008 Part 2 of BS 7671:2008 deals with definitions which are inherently an essential part of any set of rules giving precise meaning to the terms used throughout. The British Standard now contains some 250 definitions, some of which have been added or modified, to a
34 6 A Practical Guide to The Wiring Regulations greater or lesser extent, in the new edition of BS The reader is strongly encouraged to become familiar with the definitions, which will be beneficial in acquiring a broader understanding of the regulatory requirements. 1.3 Supporting publications The Institution of Engineering and Technology (IET), formerly the Institution of Electrical Engineers, has published a number of supporting publications which give background information and guidance to the installation designer, installer, verifier and others in the implementation and application of BS The guidance documents comprise: IEE Guidance Note No. 1: IEE Guidance Note No. 2: IEE Guidance Note No. 3: IEE Guidance Note No. 4: IEE Guidance Note No. 5: IEE Guidance Note No. 6: IEE Guidance Note No. 7: IEE Guidance Note No. 8: IEE On-site Guide: Selection and erection; Isolation and switching; Inspection and testing; Protection against fire; Protection against electric shock; Protection against overcurrent; Special locations; Earthing and bonding; Guidance for the small installation. The Guidance Notes published by the IET are essential reading for all those involved in electrical installation work, as is the Electrical Safety Council s Technical Manual. Constant reference to these documents, in addition to BS 7671 and this guide, will assist in achieving safe and economic installation designs. NICEIC s Inspection, Testing and Certification book is also considered to be essential reading for those involved in the verification of new installations, as well as those who carry out periodic inspection and testing of existing installations. NICEIC s Guide to Periodic Inspection and Testing of Domestic Electrical Installations is another useful source of guidance, within its particular subject area.
35 2 Electricity, the law, standards and codes of practice 2.1 General It is not the intention here to examine in detail all the statutory requirements relating to the hazards of electricity, but merely to draw to the reader s attention that such requirements do exist. The regulations made under the various acts should, therefore, be consulted to enable those involved with electricity to meet their statutory obligations. Table 2.1 summarizes some of the statutory documents relating to electrical installations and serves only as a quick reference. A rigorous commentary and analysis of the implications of these statutory regulations is given in Electrical Safety and the Law by Ken Oldham Smith (see Bibliography) and published by Blackwell Science. References to a British Standard Code of Practice (CP) are intended only to bring to the designer s (and installer s and verifier s) attention that the requirements of the CP need to be met in addition to those embodied in BS Electricity: the hazards The principal hazards envisaged by the statutory regulations relate both to electrical machines and other current-using equipment and to the fixed installation. BS 7671 (see Regulation 131.1) addresses the requirements for safety for fixed installations, where the hazards are perceived to be: shock currents; excessive temperatures likely to cause burns, fires and other injurious effects; ignition of potentially explosive atmosphere; undervoltages, overvoltages and electromagnetic influences likely to cause or result in injury or damage; A Practical Guide to The Wiring Regulations: 17th Edition IEE Wiring Regulations (BS 7671:2008) Fourth Edition Geoffrey Stokes and John Bradley Geoffrey Stokes and John Bradley. Published by John Wiley & Sons, Ltd
36 8 A Practical Guide to The Wiring Regulations Table 2.1 Acts, statutory regulations and associated legal requirements a Ref Title Comment A Electricity Safety, Quality and Continuity Regulations 2002 (ESQCR) Applies to all installations that obtain their supply from the public network. Part VII deals with supply to consumers installations. Failure to comply with the fundamental requirements for safety (Chapter 13 of BS 7671) may result in the distributor discontinuing supply (See Regulation 26 of ESQCR). Where the supply is protective multiple earthing (PME), the consumer must comply with ESQCR particularly as regards main protective bonding. B The Health and Safety at Work etc Act 1974 Applies generally in all places where a work activity is undertaken. C The Management of Health and Safety at Work Regulations 1999 Generally applicable. D The Provision and Use of Work Equipment Regulations 1998 Generally applicable. E Electricity at Work Regulations 1989 (EWR) Applies to all installations in places where a work activity is undertaken. For guidance see HSE HS(R)25 Memorandum of Guidance on the Electricity Regulations Regulation 15 addresses the requirements for adequate working space and means of access. F Electricity at Work Regulations (Northern Ireland) 1991 (EWR) Applies to all installations in places where a work activity is undertaken. For guidance see Health and Safety Agency s HAS 55 Memorandum of Guidance on the Electricity at Work Regulations (Northern Ireland) Regulation 15 addresses the requirements for adequate working space and means of access. G The Personal Protective Equipment at Work Regulations 1992 Generally applicable. H The Workplace (Health, Safety and Welfare) Regulations 1992 Generally applicable.
37 Electricity, the law, standards and codes of practice 9 I The Manual Handling. Operating Regulations 1992 Generally applicable. J The Health and Safety (Display Screen Equipment) Regulations 1992 Generally applicable. K The Low Voltage Equipment (Safety) Regulations 1994 Equipment must comply with European ENs, IEC standards, national safety provisions, and/or national standards. L The Plugs and Sockets etc. (Safety) Regulations 1994 Applies to domestic-type installations. Relates to requirements for safety in plugs, sockets, adaptors and fuses, etc. M Cinematograph (Safety) Regulations 1955 (made under the Cinematograph Act 1955 and/or the Cinematograph Act 1952) Applies to cinemas and the like. Where the general lighting and the safety lighting is by electricity, there must be at least two power sources of supply (i.e. there must be a source to power emergency lighting on failure of general lighting by, for example, mains failure). N Caravan Sites and Control of Development Act 1960 Applies to caravan park installations. Model Standards (1977) issued by the Department of Environment. O Consumer Protection Act 1987 Generally applicable. P Approval of Safety Standards Regulations 1987 Generally applicable. Q Consumer Safety Act 1987 Generally applicable. R Trading Standards Act 1968 Generally applicable. S Restrictive Trade Practices Act 1976 Generally applicable. T The Regulatory Reform (Fire Safety) Order 2005 Generally applicable. U Agricultural (Stationary Machinery) Regulations 1959, as amended Applies to agricultural and horticultural installations. Specific requirements relating to starting and stopping rotating and other machines. (continued overleaf )
38 10 A Practical Guide to The Wiring Regulations Table 2.1 (continued) Ref Title Comment V Highly Inflammable Liquids and Liquefied Petroleum Gases Regulations 1972 Applies to all installations where such substances are used. See the APEA/IP Guide mentioned in Section 13.4 of this guide for guidance on filling stations. W Dangerous substances and Explosive Atmospheres Regulations 2002 Applies to all installations where such substances are used or such atmospheres exist. X Petroleum (Consolidation) Act 1928, as amended Applies to all installations where such substances are used. Under this legislation, local authorities are empowered to grant licences for premises where such substances are stored. Substances other than petroleum are included. Y Local Government (Miscellaneous Provisions) Act 1982 Applies to installations in the UK mainland in places of public entertainment. Includes theatres, places for dancing and music, etc. Applies to installations in the UK of HV luminous tube signs. See also BS 559 Specification for electric signs and high-voltage luminous-discharge-tube installations, and BS EN Signs and luminous-discharge-tube installations operated from a no-load voltage exceeding 1 k V at not exceeding 10 k V, as applicable. Z Local Government (Miscellaneous Provisions) (Northern Ireland) Order 1985 Applies to petrol filling station installations in Northern Ireland. Applies to installations in Northern Ireland in places of public entertainment. Includes public houses, clubs, dance halls and church halls, etc. A1 Civic Government (Scotland) Act 1982 Applies to installations in Scotland in places of public entertainment. Includes theatres, places for dancing and music, etc. Applies to installations in Scotland of HV luminous tube signs. See also BS 559 Specification for electric signs and high-voltage luminous-discharge-tube installations. B1 Building Standards (Scotland) Regulations 2004 Applies to installations in Scotland. See row C1 of this table.
39 Electricity, the law, standards and codes of practice 11 C1 Technical Handbooks Technical Handbooks provide guidance on achieving the standards set in the Building (Scotland) Regulations 2004 and are available in two volumes, for Domestic buildings and for Non-domestic buildings, from Scottish Building Standards. D1 The Building Regulations 2000 as amended. Applies generally to buildings and indirectly related to electrical installation work except in respect of dwellings. See row E1 of this table. E1 Approved Documents Approved Documents provide guidance on meeting the requirements of the Building Regulations 2000 (as amended) for England and Wales. They are available from Communities and Local Government. F1 Building Regulations (Northern Ireland) 2000 Applies to certain aspects of electrical installations. See row G1 of this table. G1 Technical booklets Technical booklets are prepared by the Department of Finance and Personnel and provide for certain methods and standards of building which, if followed, will satisfy the requirements of the Building Regulations (Northern Ireland) H1 The Health and Safety (Safety Signs and Signals) Regulations 1996 Applies generally. Intended to remove confusion in the message intended to be conveyed by the sign. I1 Factories Act 1961 Applies to factories generally. J1 The Electrical Equipment (Safety) Regulations 1994 Applies generally. K1 The Construction (Design and Management) Regulations Applies generally. a This listing is intended as a guide only to some of the statutory requirements and should not be regarded as exhaustive.
40 12 A Practical Guide to The Wiring Regulations mechanical movement of electrically actuated equipment, in so far as such injury is intended to be prevented by electrical emergency switching or by electrical switching for mechanical maintenance of nonelectrical parts of such equipment; power supply interruptions and/or interruption of safety services; arcing, likely to cause blinding effects, excessive pressure and/or toxic gases. The Health and Safety Executive (HSE), in a note to BS 7671, states that it regards an electrical installation carried out in accordance with the requirements of BS 7671 as likely also to afford compliance with the relevant aspects of the Electricity at Work Regulations The law Electricity Safety, Quality and Continuity Regulations 2002 The Electricity Safety, Quality and Continuity Regulations 2002, as amended, which replaced the Electricity Supply Regulations 1988, are applicable to both public and private electricity supplies from licensed suppliers. The regulations are intended to prevent danger to persons, livestock or domestic animals. The hazards envisaged are burns, electric shock, injury from mechanical movement, fire and explosion, attendant upon the generation, transformation, transmission, distribution or use of electricity. The requirements apply to all work undertaken from the introduction of the regulations on 31 January The provisions are not retrospective, except that the new requirements will need to be met when material alterations are carried out to existing works. The regulations cover, for example, such matters as definitions, voltage ranges and limits, neutral continuity and earthing, underground cables, overhead lines, safety and reliability, maximum voltages, limits on supply voltages, protective measures, inspection, enclosed spaces and consumers installations The Electricity at Work Regulations 1989 (EWR) The Electricity at Work Regulations 1989, made under the umbrella of the Health and Safety at Work etc. Act 1974, came into force on the mainland on 1 April 1990 and are intended to protect all persons at their work environment except domestic servants in households (alas a dying breed); in rare cases, an exemption certificate may be granted by the HSE. A similar set of regulations, entitled The Electricity at Work Regulations (Northern Ireland) 1991, came into force in Northern Ireland on 6 January Alleged infringement of certain aspects of these regulations may result in criminal proceedings against those responsible, who would only have Regulation 29 to use in defence; such defence would require the duty holder to establish that they took all reasonable steps and exercised all due diligence to prevent such an offence. The authoritative guidance to these regulations is given in Memorandum of Guidance on the Electricity at Work Regulations 1989 (HS[R]25), published by the HSE, for the mainland. For Northern Ireland, a similar document is published entitled Memorandum of Guidance on the Electricity at Work Regulations (Northern Ireland) Further guidance in the province may be obtained from the Department of Economic Development.
41 Electricity, the law, standards and codes of practice Standards and codes of practice The IEE Wiring Regulations: BS 7671 The requirements of BS 7671 are not statutory requirements but are referred to in the Electricity Safety, Quality and Continuity Regulations 2002 (as amended) as being an acceptable standard which will satisfy those statutory regulations. Additionally, the HSE considers that compliance with BS 7671 will afford compliance with the relevant aspects of the Electricity at Work Regulations BS 7671 also often forms part of a contract, but when so used it must be cited in its entirety and not selectively quoted. Although the regulations in BS 7671 are recommendations only, the designer and installer should consider their use desirable in order to fulfil all the requirements of the various statutory regulations Electric signs and high-voltage luminous-discharge-tube installations: BS 559 and BS EN The electrical installation of electric signs and high-voltage (HV) luminous-discharge-tube installations is within the scope of BS Installations, therefore, need to meet those requirements and the recommendations laid down in BS 559 Specification for design, construction and installation of signs or in BS EN Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kv but not exceeding 10 kv, as applicable Emergency lighting: BS 5266 Emergency lighting installations are embraced by BS 7671, and such installations will need to comply with both the recommendations of BS 7671 and BS 5266 Emergency Lighting and in particular Part 1 Code of practice for the emergency lighting of premises Electrical equipment for explosive gas atmospheres: BS EN Electrical installations in explosive gas atmospheres fall within the scope of BS Such installations, therefore, need to comply with BS EN In particular, Parts 10, 14 and 17 are applicable to electrical installation work Electrical equipment for use in the presence of combustible dust: BS EN and BS EN BS EN and BS EN apply to the selection, installation and maintenance of equipment protected by enclosures. They also address methods of determining minimum ignition temperatures Electrical installations in opencast mines and quarries: BS 6907 This standard addresses, among other things, general recommendations for the protection against direct contact and protection against indirect contact (referred to in BS 7671:2008 as basic protection and fault protection respectively).
42 14 A Practical Guide to The Wiring Regulations Fire detection and alarm systems for buildings: BS 5839 Installations of fire detection and alarm systems for buildings are embraced by BS Such installations will need to comply both with BS 7671 and the recommendations given in BS 5839 Fire detection and alarm systems for buildings, and in particular with Part 1. The standard has the following parts: Part 1 Code of practice for system design, installation, commissioning and maintenance; Part 2 Specification for manual call points; Part 3 Specification for automatic release mechanisms for certain fire protection equipment; Part 4 Specification for control and indicating equipment; Part 5 Specification for optical beam smoke detectors; Part 6 Code of practice for the design, installation and maintenance of fire detection and alarm systems in dwellings; Part 8 Code of practice for the design, installation and servicing of voice alarm systems; Part 9 Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems Telecommunications systems: BS 6701 Installations which are subject to the Telecommunications Act 1984 are included within the scope of BS The electrical installation part of such installations will need to comply with the requirements of BS 7671 and BS 6701 Telecommunications equipment and telecommunications cabling. Specification for installation, operation and maintenance Electric surface heating: BS 6351 Requirements for the installation of electrical surface heating are included in BS 7671 and BS 6351 Electric surface heating. BS 6351 has three parts: Part 1 Specification for electric surface heating devices; Part 2 Guide to the design of electric surface heating systems; Part 3 Code of practice for the installation, testing and maintenance of electric surface heating systems Lightning protection: BS EN BS 7671 does not embrace the various aspects of the installation of lightning protection systems which are covered by BS EN Protection against lightning, except to the extent that requirements are given with regard to equipotential bonding of the lightning protection systems to the electrical installation.
43 Electricity, the law, standards and codes of practice Lift installations: BS 5655 and BS EN 81-1 The aspects of lift installations covered by BS 5655 Lifts and service lifts and BS EN 81-1 Safety rules for the construction and installation of lifts are not addressed by BS Electrical installation aspects not covered by the standard should meet the requirements of BS Equipment The legal requirements relating to all equipment, embodied in the Low Voltage Electrical Equipment (Safety) Regulations 1989, demand that the order of precedence of safety standards be Harmonized European Standards Euro Norms (ENs); International safety provisions (e.g. IEC Standards); National safety provisions: Additionally, all equipment must be fit for purpose, as the law demands, bearing in mind the purpose to which the equipment is to be put, its use and the environmental conditions in which it is to be used.
44
45 3 Scope, object and fundamental principles 3.1 General Part 1 of the BS 7671:2008 is divided into three chapters: Chapter 11 deals with the scope, Chapter 12 addresses the object and effects and Chapter 13 lays down the fundamental principles for safety. As we shall see later, the measures for safety are given in Chapters 41 to 44, though reference to other parts of BS 7671:2008 will, of course, be necessary. BS 7671 and this Guide commonly use the term equipment as an abbreviation for electrical equipment, which is defined in Part 2 of BS 7671:2008 as: Any item for such purposes as generation, conversion, transmission, distribution or utilisation of electrical energy, such as machines, transformers, apparatus, measuring instruments, protective devices, wiring materials, accessories, appliances and luminaires. When so used, the term equipment collectively relates to all and, unless further specified, to every item of installation material. Where there is doubt as to the suitability of equipment to the purposes for which it is to be used, the designer must consult the manufacturer in order to establish that the equipment is appropriate for the intended use and compatible with other proposed equipment. Where compliance with protective measures stipulated in Parts 3 7 is achieved, the broad-based fundamental principles for safety in Chapter 13 are likely to be satisfied. Where alternative measures are used, the designer would need to be able to argue that these provide for no less a degree of safety. 3.2 Scope General The first part of Regulation gives a fairly comprehensive, but not exhaustive, list of electrical installations to which the regulations apply. The list now includes the additional items of: A Practical Guide to The Wiring Regulations: 17th Edition IEE Wiring Regulations (BS 7671:2008) Fourth Edition Geoffrey Stokes and John Bradley Geoffrey Stokes and John Bradley. Published by John Wiley & Sons, Ltd
46 18 A Practical Guide to The Wiring Regulations Table 3.1 Modifications to certain types of installation BS 7671:2001 (as amended) BS 7671:2008 Construction sites, exhibitions, fairs and other installations in temporary buildings stage and broadcasting applications Highway power supplies and street furniture, and outdoor lighting Construction sites, exhibitions, shows, fairgrounds and other installations for temporary purposes including professional External lighting and similar installations marinas; mobile and transportable units; photovoltaic systems; low-voltage (LV) generating sets. Additionally, certain of the familiar categories have been modified as indicated in Table 3.1. It is clear that the types of electrical installation listed in the regulation are for illustrative purposes, and that other types of installation may also fall within the scope of BS The second section of this regulation gives a list of types of circuit and wiring systems to which BS 7671:2008 applies. The list is virtually the same as in BS 7671:2001, namely: Circuits supplied at nominal voltages up to and including 1000 V a.c. or 1500 V d.c. For a.c., the preferred frequencies which are taken into account are 50, 60 and 400 Hz. The use of other frequencies for special purposes is not excluded. Circuits other than the internal wiring of apparatus, operating at voltages exceeding 1000 V and derived from an installation having a voltage not exceeding 1000 V a.c. (e.g. discharge lighting, electrostatic precipitators). Wiring systems and cables not specifically covered by an appliance standard. All consumer installations external to buildings. Fixed wiring for communication and information technology, signalling, control and the like (excluding internal wiring of equipment). The addition to, or alteration of, existing installations and also those parts of existing installations that are affected by the addition or alteration. This regulation lists instances where BS 7671 may need to be supplemented by the requirements or recommendations of other British Standards, or by the requirements of the person ordering the work. In this section, in addition to the previously included reference to BS 559, with regard to electric signs and HV luminous discharge-tube installations, a reference has been added to BS EN 50107, relating to such installations. Also, the previous reference to BS EN for electrical apparatus in potentially explosives gas atmospheres has been updated to BS EN With regard to electrical apparatus in the presence of combustible dust, a reference has been added to BS EN 61241, in addition to the previously included reference to BS EN Finally, a reference has been added to BS 7909, relating to temporary distribution systems for entertainment-related purposes.
47 Scope, object and fundamental principles 19 Table 3.2 Related standards Standard no. BS 559 BS EN BS 5266 BS EN BS EN BS EN BS 5839 BS 6701 BS 6351 BS 6907 BS 7909 Subject matter of standard Electric signs and HV luminous-tube installations Emergency lighting Electrical apparatus for explosive gas atmospheres Electrical apparatus for use in the presence of combustible dust Fire detection and alarm systems in buildings Telecommunications systems Electric surface heating systems Electrical installations for opencast mines and quarries Design and installation of temporary distribution systems delivering a.c. supplies for lighting, technical services and other entertainment-related purposes Table 3.2 summarizes the standards to which reference is made in the regulation, the requirements of which supplement the requirements of BS 7671 for particular installations. As will be seen from Table 3.2, reference is made to BS 6907 to include electrical installations for opencast mines and quarries. However, Regulation confirms that those aspects of mines and quarries specifically covered by statutory regulations are still excluded from the scope of BS Very significantly, as with the earlier edition of BS 7671, there is no distinction made, in terms of safety, between permanent and temporary installations. It follows, therefore, that both permanent and temporary installations need to comply fully with the requirements of BS Exclusions from the scope Regulation details those installations which have been excluded from the scope. The list of exclusions, which is given below, is essentially the same as in BS 7671:2001, except that the reference to BS 6651 for lightning protection has been updated to BS EN 62305, a reference has been added to BS EN 81-1 for lift installations, and an item for electrical equipment of machines has been added to the list: systems for distribution of electricity to the public; railway traction equipment, rolling stock and signalling equipment; equipment of motor vehicles, except those to which the requirements of the regulations concerning caravans are applicable; equipment on board ships covered by BS 8450; equipment on mobile and fixed offshore installations; equipment of aircraft; those aspects of mines and quarries specifically covered by statutory regulations;
48 20 A Practical Guide to The Wiring Regulations radio interference suppression equipment, except so far as it affects safety of the electrical installation; lightning protection of buildings and structures covered by BS EN 62305; those aspects of lift installations covered by BS 5655 and BS EN 81-1; electrical equipment of machines covered by BS EN Equipment BS 7671 does not apply to equipment except to the extent of the selection and erection of that equipment. Constructional requirements of prefabricated equipment are covered separately by appropriate specifications, usually British Standards, CENELEC Standards and/or IEC Standards. Section 113 covers this point and further demands that the equipment complies with appropriate standards Relationship with statutory authorities As stated in Section 114, the rules in BS 7671 are not statutory requirements. However, they may be cited in a court of law in order to claim compliance with statutory requirements or indeed to claim noncompliance. Reassuringly, Section 114 also states that where the supply has been given in accordance with the Electricity Safety, Quality and Continuity Regulations 2002, as amended, it is deemed that the connection with Earth of the neutral of the supply is permanent and, by implication, reliable Installations in premises subjected to licensing Section 115 states that for installations which are subject to licensing conditions or where another authority exercises statutory control, not only have that authority s requirements to be ascertained, but they must also be adhered to both in the design of the installation and its execution. In the case of licensing, the authority s requirements should also be sought with regard to periodic inspection and testing of installations. 3.3 Object and effects General Regulation states that Chapter 13 of BS 7671 addresses the fundamental principles but does not give the detailed technical requirements. Therefore, it follows that Parts 3 7 give greater detail of the methods of achieving the fundamental principles laid down in Chapter 13. As indicated in Regulation 120.3, the various parts of BS 7671 giving technical requirements intended to afford compliance with the fundamental principles are Part 3: Assessment of general characteristics; Part 4: Protection for safety;
49 Scope, object and fundamental principles 21 Part 5: Selection and erection; Part 6: Inspection and testing; Part 7: Special installations or locations. The regulation goes on to say that any intended departure from BS 7671 should receive special consideration by the installation designer, and must be recorded on the Electrical Installation Certificate. It is important to note that this dispensation of sanctioning a departure is not afforded to anyone other than the designer, who must accept responsibility for such noncompliance New materials and inventions From time to time, new ideas for equipment are brought to the industry which, naturally, have not been tried and tested over time in service conditions. It is not the intention of BS 7671 to suppress such innovations and their introduction into electrical installations, and this fact is acknowledged in BS If a new material or invention is used within an installation then the designer is required, by Regulation 120.4, to ascertain that the degree of safety is no less than that which would have prevailed had the new material or new invention not been used. This would, in all probability, involve a third-party certification body, which would be requested to make an assessment of the product and certify the degree of safety provided by it in use. When used, the new product would nevertheless constitute a deviation from BS 7671 and, consequently, would need to be recorded on the Electrical Installation Certificate. It goes without saying that any departure from BS 7671 needs very careful consideration by the designer. 3.4 Fundamental principles General Regulation makes clear that BS 7671 is intended to protect persons, property and livestock against dangers and damage which may occur when the installation is used as intended. BS 7671 assumes that, in providing protective measures for safety, the installation will be used in the manner intended and with reasonable care, which may include preventative maintenance as well as proper routine attention. The regulation also states that the requirements to provide for the safety of livestock are applicable in locations intended for them. Chapter 13 of BS 7671:2008 has been reorganized to some extent, with the sections having been renumbered and some new regulations having been introduced. The chapter still sets out the fundamental principles for safety on which all the detailed technical requirements are based. Table 3.3 shows the renumbering of the sections of Chapter 13. Regulation states in new terms the hazards of electricity addressed by BS These are summarized in Table 3.4.
50 22 A Practical Guide to The Wiring Regulations Table 3.3 Renumbering of the sections of Chapter 13 BS 7671:2001 (as amended) BS 7671:2008 Section no. Issue addressed Section no. Issue addressed 130 Protection for safety 131 Protection for safety 131 Design 132 Design 132 Selection of electrical equipment 133 Erection, verification, and periodic inspection and testing of electrical installations 133 Selection of electrical equipment 134 Erection and initial verification of electrical installations 135 Periodic inspection and testing Table 3.4 Changes in terminology of the hazards BS 7671:2001 (Regulation ) BS 7671:2008 (Regulation 131.1) Shock currents Excessive temperatures likely to cause burns, fires and other injurious effects Mechanical movement of electrically actuated equipment, in so far as such injury is intended to be prevented by emergency switching or be electrical switching off for mechanical maintenance of nonelectrical parts of such equipment Explosion Shock currents Excessive temperatures likely to cause burns, fires and other injurious effects Ignition of potentially explosive atmosphere Undervoltages, overvoltages and electromagnetic influences likely to cause or result in injury or damage Mechanical movement of electrically actuated equipment, in so far as such injury is intended to be prevented by emergency switching or be electrical switching off for mechanical maintenance of nonelectrical parts of such equipment Power supply interruptions and/or interruption of safety services Arcing or burning, likely to cause blinding effects, excessive pressure, and/or toxic gases Electric shock: basic protection BS 7671:2008 uses the term basic protection to refer to protection of persons and livestock against electric shock as a result of making contact with live parts, whereas BS 7671:2001 used the term protection against direct contact for this.
51 Scope, object and fundamental principles 23 Regulation refers to two methods by which basic protection can be accomplished: preventing a current from passing through the body of any person or any livestock; limiting the current which can pass though a body to a nonhazardous value Electric shock: fault protection The term fault protection is used in BS 7671:2008 to refer to protection of persons and livestock against electric shock as a result of making contact with exposed-conductive-parts that have become live under fault conditions, whereas BS 7671:2001 used the term protection against indirect contact for this. Regulation refers to the following three methods by which fault protection may be accomplished, the first two of which are essentially the same as given above relating to basic protection: preventing a current resulting from a fault from passing through the body of any person or any livestock; limiting the current which can pass though a body to a nonhazardous value; limiting the duration of a current resulting from a fault which can pass through the body to a nonhazardous time period. Regulation goes on to confirm that, in connection with fault protection, the application of the method of protective equipotential bonding is one of the important principles for safety Protection against thermal effects Regulation requires that the electrical installation shall be so arranged that the risk of ignition or flammable materials due to high temperature or electric arc is minimized and that, during normal operating conditions of the electrical equipment, there shall be minimal risk of burns to persons or livestock. With regard to protection against harmful thermal effects of heat or thermal radiation emitted by adjacent electrical equipment, Regulation requires protection to be provided to persons, fixed equipment and materials, particularly where there are likely to be any of the following consequences: combustion, ignition or degradation of materials; risk of burns; impairment of the safe function of installed equipment Protection against overcurrent Regulation requires that persons or livestock are protected against injury, and that property is protected against damage, due to excessive temperatures or electromechanical stresses caused by any overcurrents likely to arise in live conductors. A note to the
52 24 A Practical Guide to The Wiring Regulations regulation explains that protection may be achieved by limiting the overcurrent to a safe value and/or duration Protection against fault current Regulation requires conductors and any other parts likely to carry fault current to be capable of carrying that current without attaining excessive temperature. A further requirement, which did not appear in the corresponding Regulation of BS 7671:2001, is that electrical equipment, including conductors, shall be provided with mechanical protection against electromechanical stress of fault currents as necessary to prevent injury or damage to persons, livestock or property. A note to the regulation explains that, for live conductors, compliance with Regulation assures their protection against overcurrents caused by faults Protection against voltage disturbances and measures against electromagnetic influences The scope of Regulation Group of BS 7671:2008 is wider than that of the corresponding Regulation Group of BS 7671:2001, which related only to protection against overvoltage. As was required jointly by Regulations and of BS 7671:2001, Regulations and of BS 7671:2008 require that persons and livestock are protected against injury, and that property is protected against any harmful effects, resulting from: a fault between live parts of circuits supplied at different voltages; overvoltages likely to arise from atmospheric events or from switching. A note to Regulation points out that protection against direct lightning strikes is dealt with in BS EN The requirements of Regulations and are new to Part 1 of BS The first of these regulations requires persons to be protected against injury, and property to be protected against damage, as a consequence of undervoltage and any subsequent voltage recovery. The second of these regulations requires an installation to have an adequate level of immunity against electromagnetic disturbances so that it will function correctly in the specified environment. The regulation also requires the installation design to take account of the anticipated electromagnetic emissions generated by the installation or by the installed equipment Protection against supply interruption The requirements Regulation of BS 7671:2008 are new to Part 1. The regulation requires that, where danger or damage is expected to arise due to an interruption of supply, suitable provisions are made in the installation or installed equipment.
53 Scope, object and fundamental principles 25 Table 3.5 Summary of Section 132 Design Regulation Title Dealing with Group General Installation to protect persons, livestock and property and to function properly for the intended use Characteristics of available supply or supplies Characteristic of supply(ies) to be determined Nature of demand Number and type of circuits to be established Electrical supply systems for safety services or standby electrical supply systems Characteristics of supply for safety services, and circuits to be supplied, to be determined Environmental conditions Equipment to be suitable for environmental conditions including risk of fire or explosion Cross-sectional area of conductors Type of wiring and method of installation Conductors to be of adequate cross-sectional area, including for harmonics and thermal insulation Wiring system and method of installation to be suitable for location etc Protective equipment Protective devices to be suitable for application Emergency control Emergency interrupting devices to be easily recognizable and operable Disconnecting devices Disconnecting devices to be provided for maintenance, testing, fault detection and repair Prevention of mutual detrimental influence Accessibility of electrical equipment Documentation for the electrical installation Harmful influences between electrical installation and other installations to be avoided, including electromagnetic interference Adequate space to be provided for installation, replacement, maintenance, testing, fault detection and repair Appropriate documentation to be provided for the installation Protective devices and switches Single-pole devices in line conductor only and requirements when switches are inserted in earthed neutral conductors Isolation and switching Removal of voltage from equipment including electric motors to prevent danger
54 26 A Practical Guide to The Wiring Regulations Additions and alterations to an installation Regulation requires that for an alteration or addition to an existing installation the rating and condition of the existing equipment which is utilized for the altered or addition installation must be confirmed as being satisfactory, including the supply. Additionally, where the alteration or addition uses automatic disconnection of supply (ADS) for fault protection, the earthing and bonding must also be of sufficient cross-sectional area Design Section 132 of BS 7671:2008, dealing with design, is summarized in Table Selection of electrical equipment Section 133 of BS 7671:2008, containing 10 regulations, requires equipment to be suitably selected, as summarized in Table Erection, initial verification of electrical installations, and periodic inspection and testing The requirements for erection and initial verification of electrical installations and those for periodic inspection and testing are contained in Sections 134 and 135 respectively and are summarized in Table 3.7. As in previous editions of BS 7671, the requirement contained in Regulation for good workmanship and proper materials to be used is, as one would expect, retained; these essential elements are the cornerstones of sound installation erection work. By Table 3.6 Summary of Section 133 Selection of electrical equipment Regulation Title Dealing with Group General Equipment to comply with standards unless agreed otherwise Characteristics Equipment to have suitable characteristics to suit the values and conditions on which the design of the installation is based Voltage These four regulations require equipment to be Current selected to suit voltage, current, frequency and Frequency power Power Conditions of installation Equipment to be selected to be suitable for the environmental conditions, or otherwise protected Prevention of harmful effects Electrical equipment not to cause harmful effects on other equipment or the supply
55 Scope, object and fundamental principles 27 Table 3.7 Summary of Section 134 Erection and initial verification of electrical installations, and Section 135 Periodic inspection and testing Regulation Title Dealing with Good workmanship and proper materials Characteristics of equipment not to be impaired during erection of installation Conductors to be identified Electrical joints and connections to be adequate Design temperatures not to be exceeded Equipment causing high temperatures or arcs to be suitably located or guarded Suitable warning signs and/or notices to be provided where necessary for safety purposes Initial verification Appropriate inspection and testing to be performed during erection and upon completion of an installation or an addition or alteration, and appropriate certification to be issued Periodic inspection and testing Recommendation for subsequent periodic inspection and testing required implication, the regulation requires that established methods, equipment and materials are to be used, but it does not rule out the use of new materials provided they offer no less a degree of safety. The regulation also contains the requirement for electrical equipment to be installed in accordance with the instructions provided by the manufacturer. Regulation goes on to require that equipment must not be impaired by the installation process.
56
57 4 Assessment of general characteristics 4.1 General Part 3 of BS 7671 requires the electrical installation designer to make an assessment of the entire electrical system. An electrical installation forms part of the complete system, the other constituent parts being the LV supply source and the interlinking LV distribution lines. Regulation requires this assessment to include the characteristics of the installation, such as the purpose for which the installation is to be used, its structure generally, the nature of the supply to the installation, the external influences to which equipment will be exposed, the compatibility and maintainability of that equipment in service, any safety services (such as emergency lighting and fire alarm systems) and the need for continuity of service. The need for this assessment is obvious, in that the particular characteristics of the supply and installation will influence, if not dictate, the methods used to protect against the hazards referred to in Chapter 13 (electric shock, excessive temperatures, and so on). They will also have a bearing on the choice of equipment, including wiring systems. Additionally, before any design of the installation is contemplated, an assessment of the supply characteristics is required and due account will need to be taken of the implications of those characteristics on the installation design. 4.2 Loading, maximum demand and diversity General Whilst maximum demand and diversity are not defined in BS 7671, it is necessary to be clear that such terms are understood by all concerned in the design process. For example, maximum demand may mean different things to the supply engineer and the installation design engineer. In this text, the following meanings have been assigned to the terms used: A Practical Guide to The Wiring Regulations: 17th Edition IEE Wiring Regulations (BS 7671:2008) Fourth Edition Geoffrey Stokes and John Bradley Geoffrey Stokes and John Bradley. Published by John Wiley & Sons, Ltd
58 30 A Practical Guide to The Wiring Regulations maximum demand the maximum anticipated installation load plus any allowance for future loading (i.e. the potential load); connected load the total of all electrical loads; diversity the ratio of maximum demand to the connected load. Diversity, therefore, can be represented by diversity = maximum demand connected load (4.1) From Equation (4.1) it can be readily seen that diversity is never going to be more than unity, or 100% in percentage terms (the more usual way of expression). Whilst the connected load is fairly straightforward to assess, the prediction of the maximum demand calls for considerable skill and judgement by the electrical designer. To apply a diversity of one (or 100%) would, of course, meet all the safety requirements, but an installation designed on this basis might prove to be exceedingly costly and much over-engineered. To provide an economic design which meets the safety requirements needs design experience, skill and not a little judgement in establishing a figure for the actual load (i.e. maximum demand). In load assessments, certain assumptions have to be made with regard to actual current drawn by equipment. Fixed loads are easy, but this is not so for socket-outlet circuits, which may have a theoretical load many times that which is likely to be drawn in service. For example, a final ring circuit may have twelve 13 A socket-outlets protected by a 32 A fuse or circuit-breaker, each socket-outlet capable of supplying, at least for short periods, a load of 2.99 kw at 230 V (13 A 230 V), giving a total circuit current of 156 A (12 13 A). Clearly, such a scenario is not likely to occur in the real world, and the current likely to be drawn in this case must be based on all the known information related to usage of the circuit and the loads of portable and fixed equipment connected to it (the maximum permitted sustained load to be drawn by this circuit would, of course, be 32 A). As mentioned earlier, assumptions have to be made in the assessment of maximum demands and those regarding the load current of current-using equipment and at points of utilization (e.g. socket-outlets) are given in Table 4.1, which is based on Table H1 of IEE Guidance Note 1 Selection and erection. When selecting a distribution board or consumer unit, it is important to do so taking into account its rated current and rated diversity factor. It should also not be forgotten that the rated currents of the outgoing ways do not imply that the ways can take these currents continuously or for substantially long periods. Where continuous or long duration loadings exceed the long term ratings of the outgoing ways, an excessive temperature rise is attained within the equipment, which may cause premature operation of overload devices. In all cases the equipment manufacturer s instructions with regard to loading should be complied with Lighting: loading and diversity To assess the maximum demand for loading of lighting circuits, it is simply necessary to add the sum of all the lamp wattages of luminaires connected to it. The current is obtained by dividing the rated wattage of the lamp(s) by the nominal voltage (i.e. W/U n ).
59 Assessment of general characteristics 31 Table 4.1 Load demand of current-using equipment and points of utilization a Ref Equipment or point of utilization Assumed maximum demand Comments/examples A 63 A socket-outlet 63 A In the absence of precise loading, allow for maximum rated load B 32 A socket-outlet 32 A In the absence of precise loading, allow for maximum rated load C 16 A socket-outlet 16 A In the absence of precise loading, allow for maximum rated load D 13 A socket-outlet 13 A Conventional circuits excepted E 5 A socket-outlet 5 A Conventional circuits excepted F 2 A socket-outlet 0.5 A The value of load demand given should be regarded as a minimum G Known luminaries Actual load Account to be taken of power factor of luminaire H Other lighting outlets (e.g. pendants) Not less than 100 W (0.43 A at 230 V) Minimum of 100 W per lamp J Electric clocks Zero To be ignored K Shaver sockets Zero To be ignored L Bell transformers Zero To be ignored M Load of not more than Zero To be ignored 5 VA (22 ma at 230 V) N Cooker (domestic type) 10 A plus 30% of remainder of load E.g. 20 kw (86.95 A) cooker on 230 V Loading = 10A + ( ) = 39A O Cooker (domestic type) with integral socket-outlet on control unit 10 A plus 30% of remainder of load plus 5A E.g. 24 kw ( A) cooker on 230 V Loading = 10A + ( ) + 5 = 46.3A P Stationary equipment Rated current Consult the manufacturers and/or the Standard and/or rating plate a Where loadings have a power factor other than unity, allowance must be made for the current drawn at stated power factor.
60 32 A Practical Guide to The Wiring Regulations Where luminaires operate at a power factor less than unity (e.g. power-factor-uncorrected fluorescent luminaires), and in the absence of more precise information, a multiplying factor of 1.8 (see Section of this Guide) must be applied to the calculated current derived from the wattage rating. Where the actual wattage of a luminaire is not known, a minimum of 100 W per lamp must be allowed (see item H of Table 4.1 of this Guide). Diversity for lighting circuits will depend on the type of premises, and in Table H2 of IEE Guidance Note 1 Selection and erection these are given as domestic premises households, including flats 66%; commercial premises shops, offices, stores and other business premises 90%; commercial premises guest houses, small hotels, boarding houses 75%. By way of example, three shop lighting circuits with connected load (and maximum demand) of 15 A, 7 A and 12 A would represent (after applying an allowance for diversity of 0.9) a load of 30.6 A i.e. 0.9( ) on the supplying distribution board Heating: loading and diversity Assessment of heating loads is straightforward and the current is obtained by dividing the rated wattage W of the loads by the nominal voltage of the circuit (i.e. W/U n ). The power factor for such load is normally at unity unless the heater convection is fan assisted, in which case account should be taken of the motor power factor. This is generally likely to be approaching unity for the whole appliance. For thermal storage heating circuits (e.g. off-peak heaters) and for floor-warming installations, no allowance for diversity is permitted. Diversity for heating circuits will depend on the type of premises, and in Table H2 of IEE Guidance Note 1 Selection and erection these are given as domestic premises households, including flats: 100% of first 10 A plus 50% of remainder; commercial premises shops, offices, stores and other business premises: 100% of largest heater plus 75% of remaining heaters; commercial premises guest houses, small hotels, boarding houses: 100% of largest heater plus 80% of next largest heater plus 60% of remaining heaters. By way of example, five boarding house heaters, three rated at 3 kw and two rated at 2 kw, are fed from a common distribution board. With allowance for diversity, these heaters would represent a load of 9.6 kw, i.e.(1 3) + (0.8 3) + (0.6 3) + (0.6 2) + (0.6 2) Cookers: loading and diversity Diversity for cooker circuits will again depend on the type of premises, and in Table H2 of IEE Guidance Note 1 Selection and erection these are given as domestic premises households, including flats: 100% of first 10 A plus 30% of remainder plus 5 A if socket-outlet is integral to the cooker control unit;
61 Assessment of general characteristics 33 commercial premises shops, offices, stores and other business premises: 100% of largest cooker plus 80% of second largest cooker plus 60% of remaining cookers; commercial premises guest houses, small hotels, boarding houses; 100% of largest cooker plus 80% of second largest cooker plus 60% of remaining cookers. By way of example, three small hotel cookers, two rated at 12 kw and one rated at 10 kw, are fed from a common distribution board. With allowance for diversity, these cookers would represent a load of 27.6 kw, i.e (0.8 12) + (0.6 10) Water heaters: loading and diversity Diversity for instantaneous water heater circuits will depend on the type of premises, and in Table H2 of IEE Guidance Note 1 Selection and erection these are given as domestic premises households including flats: 100% of first and second largest water heater plus 25% of remainder; commercial premises shops, offices, stores and other business premises; 100% of first and second largest water heater plus 25% of remainder; commercial premises guest houses, small hotels, boarding houses: 100% of first and second largest water heater plus 25% of remainder. There is no allowable diversity for water heaters which are thermostatically controlled (e.g. immersion heaters and storage water heaters). By way of example, three office instantaneous water heaters, two rated at 7 kw and one rated at 3 kw, are fed from a common distribution board. With allowance for diversity, these water heaters would represent a load of kw, i.e (0.25 3) Motors: loading and diversity Diversity for motor circuits will depend on the type of premises, and in Table H2 of IEE Guidance Note 1 Selection and erection these are given as commercial premises shops, offices, stores and other business premises: 100% of first and second largest motor plus 80% of second largest motor plus 60% of remainder; commercial premises guest houses, small hotels, boarding houses: 100% of first and second largest motor plus 50% of remainder. By way of example, three motors in an office boiler house, two rated at 11 A and one rated at 5 A, (and all operating at 0.8 power factor), are fed from a common distribution board. With allowance for diversity, these motors would represent a load of 32.5 A, i.e. [ (0.8 5)]/0.8. This value represents the steady-state loading, and allowance should also be made for the high starting currents associated with the particular motors. The motor manufacturer must be consulted where there is doubt about the starting currents (typically six times the steady-state current). Consideration should also be given to simultaneous starting of motors and the effects on distribution circuits. Sequential starting may need to be adopted to prevent unacceptable
62 34 A Practical Guide to The Wiring Regulations cumulative starting currents. Lift motors are the subject of special consideration, and reference should be made to the requirements of BS 5655 or BS EN 81-1, as applicable Stationary equipment: loading and diversity The loading of stationary equipment will be that given by the manufacturers, and any diversity allowance which may apply will depend on the operational requirements. In the absence of precise information, the allowance given for heating may be used with caution, if appropriate Conventional circuits: loading and diversity Conventional circuit arrangements are detailed in Appendix E of the IEE Guidance Note Selection and erection. Diversity for conventional circuits will depend on the type of premises, and in Table H2 of IEE Guidance Note 1 Selection and erection these are given as domestic premises households, including flats: 100% of largest circuit plus 40% of remainder; commercial premises shops, offices, stores and other business premises: 100% of largest circuit plus 50% of remainder; commercial premises guest houses, small hotels, boarding houses: 100% of largest circuit plus 50% of remainder. By way of example, three conventional circuits in a shop, two rated at 32 A (ring final circuits) and two rated at 20 A (radial circuits), are fed from a common distribution board. With allowance for diversity, these circuits would represent a load of 68 A, i.e ( ) Socket-outlet circuits other than conventional circuits: loading and diversity Diversity for socket-outlet circuits other than conventional circuits will depend on the type of premises, and in Table H2 of IEE Guidance Note 1 Selection and erection these are given as domestic premises households, including flats: 100% of largest point plus 40% of remainder; commercial premises shops, offices, stores and other business premises: 100% of largest point plus 75% of remainder; commercial premises guest houses, small hotels, boarding houses: 100% of largest point plus 75% of all other points in main rooms plus 40% of remainder. There will be many occasions where the designer will find the installation will not fall neatly into any one of the above three categories and will need to use professional judgement and experience to assess diversity.
63 Assessment of general characteristics Arrangement of live conductors and type of earthing Arrangement of live conductors Regulation requires that an assessment be made of the number and types of live conductor. Examples given in the regulation are single-phase, two-wire a.c. and three-phase, four-wire a.c. Other arrangements which could be cited are two-wire d.c. and three-phase, three-wire a.c. systems, but it is accepted that those quoted in the above regulation are the ones more likely to be encountered in the normal course of events. In the case of public supplies, the proposed arrangements can easily be established by consultation with the electricity distributor (ED) concerned. In the event of a private distributor, consultation again will be sufficient to establish the relevant parameters. In the case of on-site generation, the designer will only need to consult the generator manufacturer or the generator nameplate to determine the arrangements of live conductors of the source Type of earthing It is important that the requirements of Regulation are met, in that an assessment of the type of earthing has to be made before the design of the installation commences. The type of earthing will have implications with regard to the value of the external earth loop impedance and to the magnitude of prospective earth fault current. In the case of public supplies, an ED providing a new connection at LV is normally required by Regulations 24(4) and 24(5) of the ESQCR to make available the combined protective earth and neutral (PEN) conductor, or, if appropriate, the protective conductor, of the supply for connection to the earthing conductor of the consumer s installation. (The expression new connection means the first electric line, or the replacement of an existing electric line, to one or more consumer installations.) However, in certain circumstances the distributor may take the view that such connection to the consumer s earthing conductor could result in danger and, therefore, not make available the PEN conductor or protective conductor of the supply for this purpose. Examples of situations where caution would be warranted are installations where it may prove difficult to attach and maintain all the necessary main protective bonding connections (e.g. farms or building sites), installations at certain wet environments (e.g. swimming pools) and certain installations outside the equipotential zone of buildings (e.g. certain types of street furniture). In addition, in the case of an electrical installation in a caravan or boat, Regulation 9 of the ESQCR forbids an ED from making available the PEN conductor of the supply for connection to the earthing conductor of the installation. Other than in the case of a new connection at LV, an ED has no obligation, legal or otherwise, to provide facilities for earthing of an electrical installation, this being the sole responsibility of the consumer. There are five basic types of earthing arrangement embodied in the systems identified by, TN-C, TN-S, TN-C-S, TT and IT, and these are shown in Figures and detailed in Part 2 of BS In the figures, the line configuration in each case represents a three-phase source with the star/neutral point earthed where appropriate. For single-phase sources, one pole of the secondary circuit would normally be earthed as indicated in the figures for the neutral point. The meanings attributed to each letter are given in Table 4.2.
64 36 A Practical Guide to The Wiring Regulations SOURCE Supply lines L 1 L 2 L 3 N Source earth electrode Supply PEN conductor (combined neutral and protective conductor) Installation PEN conductor (combined neutral and protective conductor - e.g. earthed concentric wiring system) All exposed-conductive-parts connected to PEN conductor N L 3 L 2 L 1 Additional earth electrode Consumer's installation Installation exposedconductiveparts Figure 4.1 TN-C system (three-phase installation) SOURCE Supply lines L 1 L 2 L 3 N PE Source earth electrode Supply PE protective earthing conductor (e.g. cable sheath) Installation earthing conductor All exposed-conductiveparts connected to the earthing conductor via the MET E N L 3 L 2 L 1 Consumer's installation Installation exposedconductiveparts Figure 4.2 TN-S system (three-phase installation)
65 Assessment of general characteristics 37 SOURCE Supply lines L 1 L 2 L 3 N Source earth electrode Supply PEN conductor (combined neutral and protective conductor) ED s link from supply neutral to installation MET. Separate neutral and protective conductors in installation All exposed-conductiveparts connected to earthing conductor via the MET E N L 3 L 2 L 1 Additional earth electrode Consumer s installation Installation exposedconductiveparts Figure 4.3 TN-C-S system (three-phase installation) SOURCE Supply lines L 1 L 2 L 3 N Source earth electrode Installation earth electrode Installation earthing conductor All exposed-conductive-parts connected to the earth electrode via earthing conductor and MET E N L 3 L 2 L 1 Consumer s installation Installation exposedconductiveparts Figure 4.4 TT system (three-phase installation)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
PROTECTION AGAINST ELECTRIC SHOCK by John Ware
16 become live under fault conditions. The potential of the metal enclosure is higher than that of the main earthing terminal of the installation (and that of Earth) because of a potential difference created
ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
Original Certificate DETAILS OF THE CLIENT Certificate reference: ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) Name: Address: PURPOSE
Electrical Contractors Association
Electrical Contractors Association Presents BS 7671 2008: Amendment No 1 BS 7671: 2008 Amendment No 1, 2011 IEE Wiring Regulations Now called IET Wiring Regulations History 1882 first edition of the Wiring
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Mark Coles BEng (Hons) MIEE
Requirements for Electrical Installations BS 7671:2008(2011) The IET Wiring Regulations 17 th th Edition Presenter: Mark Coles BEng (Hons) MIEE Technical Regulations Manager, IET Topics: the history the
4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
BS 7671:2008+A3:2015 MODEL FORMS
BS 7671:2008+A3:2015 MODEL FORMS Usage and Reproduction of IET Forms Subject to your agreement to the following conditions, you are permitted to, free of charge, photocopy and/or electronically manipulate
Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24
1 Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are safe. The introduction of the 17 th Edition
Trade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES
1 By kind permission of MK INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES By Mark Coles The IEE receives many enquiries relating to the inspection and testing of electrical
A B Brown. This sheet forms part of *Inspection Report Number/*Certificate Number NA/ * EC/ * PIR *Delete as applicable DB1 60898
NAPIT Electrical Test Continuation Sheet Requirements for Electrical Installations BS 767 [IEE Wiring Regulations] and for Please complete all the unshaded areas. This sheet forms part of *Inspection Report
NZECP 14: 1995 ISSN 0114-0663 COVER PAGE
NZECP 14: 1995 ISSN 0114-0663 COVER PAGE NZECP 14:1995 NEW ZEALAND ELECTRICAL CODE OF PRACTICE FOR CONTROL PROTECTION AND SWITCHBOARDS Issued by the Office of The Chief Electrical Engineer, Energy and
SELECTION OF FINAL CIRCUIT PROTECTION
SELECTION OF FINAL CIRCUIT PROTECTION By Phil Williams, Product Marketing Manager, Power Distribution Components, Eaton Executive summary The selection of devices for final circuit protection in electrical
Guide to the Selection & Use of Residual Current Devices
Guide to the Selection & Use of Residual Current Devices ET214:2005 Edition 1 Electro-Technical Council of Ireland Limited Published by the Electro-Technical Council of Ireland Limited Date of Publication:
chapter8 Testing and commissioning Unit 2 outcome 2
Testing and commissioning chapter8 Unit 2 outcome 2 It is important that electricians are not just able to construct; they should also be able to recognise faults and take action to help prevent them.
FORMS for the 17th Edition
FORMS for the 17th Edition Usage and Reproduction of IEE Forms Subject to your agreement to the following conditions, you are permitted to, free of charge, photocopy and/or electronically manipulate the
6.0 Electrical Installations
6.0 An electrical installation is a combination of electrical equipment installed to fulfill a specific purpose and having coordinated characteristics. In dealing with the electrical installation, it is
Electrical installation condition reporting:
Electrical installation condition reporting: Classification Codes for domestic and similar electrical installations FUSED 4 Issue 3 This is one of a series of Best Practice Guides produced by the Electrical
ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1
ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1 Design and Planning Specification for New Low Voltage Installations for Housing Developments 1. SCOPE This appendix to ENA
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
Level 3 Certificate in the Certification of Electrical Installations (Design, Erection and Verification of Electrical Installations) (2391-20)
Level 3 Certificate in the Certification of Electrical Installations (Design, Erection and Verification of Electrical Installations) (2391-20) www.cityandguilds.com March 2007 Version 1.0 Qualification
PART P: DOMESTIC ELECTRICAL SAFETY April 2006 Revisions (modified April 2007)
THE BUILDING REGULATIONS Guide for Householders, Designers and Builders PART P: DOMESTIC ELECTRICAL SAFETY April 2006 Revisions (modified April 2007) THE BUILDING REGULATIONS PART P : Domestic Electrical
Engineering Recommendation G81 Issue: October 2004
Engineering Recommendation G81 Issue: Part 4 - Framework for design and planning of industrial and commercial underground connected loads up to and including 11kV 2004 Energy Networks Association All rights
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Abstract This Guide is an informative listing of selected terms and definitions found in IEC Glossary entry
Regulation IO-6.0: Electrical Safety Regulations
Regulation IO-6.0: Electrical Safety Regulations 6.1 Workmanship & Material 6.2 Electrical Conductors 6.3 Overcurrent Protective Devices 6.4 Precautions against Earth Leakage and Earthfault Currents 6.5
CHECKING AND TESTING ELECTRICAL INSTALLING WORK
CHECKING AND TESTING ELECTRICAL INSTALLING WORK Department of Consumer and Employment Protection Energy Safety Preface It is a requirement of the Electricity (Licensing) Regulations 1991 that all electrical
Building Services Engineering Technician
Building Services Engineering Technician A competent Building Services Engineering Technician is expected to be able to demonstrate the following skills and competences: Systems design in the building
Engineering Recommendation G81 - Part 1: Design and Planning
PRODUCED BY THE ENGINEERING DIRECTORATE OF THE ENERGY NETWORKS ASSOCIATION Engineering Recommendation G81 - Part 1: Design and Planning Issue 2 Ammendment 1 January 2008 Framework for design and planning,
The Electricity Wiring Regulations
The Electricity Wiring Regulations (Third Edition) March 2014 Issued by: The Regulation and Supervision Bureau for the water, wastewater and electricity sector in the Emirate of Abu Dhabi The Electricity
HIGH VOLTAGE SHORE CONNECTION
Guide for High Voltage Shore Connection GUIDE FOR HIGH VOLTAGE SHORE CONNECTION NOVEMBER 2011 American Bureau of Shipping Incorporated by Act of Legislature of the State of New York 1862 Copyright 2011
ONLINE VERSION ONLINE VERSION ONLINE VERSION. 2006 edition. Electrical safety dwellings APPROVED DOCUMENT. The Building Regulations 2000
The Building Regulations 2000 P1 P Design and installation of electrical installations APPROVED DOCUMENT Coming into effect 6 April 2006 2006 edition Amendments to Approved Documents and Compliance Guides
The Electricity Wiring Regulations 2007
The Electricity Wiring Regulations 2007 Issued by: the Regulation and Supervision Bureau for the Water, Wastewater and Electricity Sector in the Emirate of Abu Dhabi www.rsb.gov.ae Revision 1 January 2009
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
ELECTRICIAN TRADE REGULATION
Province of Alberta APPRENTICESHIP AND INDUSTRY TRAINING ACT ELECTRICIAN TRADE REGULATION Alberta Regulation 274/2000 With amendments up to and including Alberta Regulation 122/2014 Office Consolidation
A Guide to 17th Edition Testing
Seaward, Bracken Hill, South West Industrial Estate, Peterlee, County Durham, SR8 2SW United Kingdom Tel: +44 (0) 191 586 3511 Fax: +44 (0) 191 586 0227 Email: [email protected] Web: www.seaward.co.uk
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
FAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
1. Electrical Equipment A) Transformer
Standards and Basic Equipment Date : 15 November 2010 1. Electrical Equipment 2. Terminology 3. Code & Standard 1. Electrical Equipment A) Transformer A1) One Transformer and 11kV Switchgear in High Rise
CODE OF PRACTICE FOR THE ELECTRICITY (WIRING) REGULATIONS
CODE OF PRACTICE FOR THE ELECTRICITY (WIRING) REGULATIONS Electrical and Mechanical Services Department 2009 Contents Page Acknowledgements 9 Part I 1. Introduction 10 2. Interpretation 11 3. Application
Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time
Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to
employed to ensure the continuing reliability of critical systems.
4 Regulations 1989, Regulation 4, places a duty on employers to provide safe systems for their workers: Regulation 4 of the Electricity at Work Regulations 1989 Systems, work activities and protective
Electrical test equipment for use on low voltage electrical systems
Electrical test equipment for use on low voltage electrical systems Guidance Note GS38 (Fourth edition) This general series guidance note is aimed at people (including electricians, electrical contractors,
IEC specifications for LV assembly switchboards
Technical set IEC specifications for LV assembly switchboards In conformity with IEC 61439-1&2 standard Specifier Guide Introduction Within the IEC 61439 series of standards for low-voltage switchgear
Insulation resistance
The insulation resistance is particularly important for the prevention of damage and injury, and for the reliability of electrical systems and equipment. On the one hand it is basis for the protection
GUIDANCE ON ELECTRICAL INSPECTIONS
GUIDANCE ON ELECTRICAL INSPECTIONS Electricity Electricity is a versatile and convenient source of energy. However, it can be potentially dangerous if the system has not been properly designed, installed,
GUIDE TO THE AM2 EXAM
AM2 GUIDE TO THE AM2 EXAM What is AM2? AM2 or the Achievement Measurement 2 is a practical performance skill test administered by the National Electrotechnical Training (NET). You must take the AM2 test
The easy way to build switchgear and controlgear assemblies in compliance with the regulations
The easy way to build switchgear and controlgear assemblies in compliance with the regulations A guide for partially type-tested switchgear and controlgear assemblies in compliance with EN 60 439 What
ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007. Part 3: Electricity
Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007 Part 3: Electricity 9 Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007 Part
QUALIFICATION HANDBOOK
QUALIFICATION HANDBOOK Level 4 Award in the Design and Verification of Electrical Installations (2396-01) November 2011 Version 1.0 Qualification at a glance Subject area City & Guilds number 2396 Age
Healthcare interpretation of IEE Guidance Note 7 (Chapter 10) and IEC 60364-7-710 for
Healthcare interpretation of IEE Guidance Note 7 (Chapter 10) and IEC 60364-7-710 for Electrical Installations in Medical Locations Annex to MEIGaN June 2005 Queries concerning this document should be
Electrical Resistance Resistance (R)
Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13
Interfacing electrification and system reliability Roger White Professional Head of Electrification and Plant Rail Abstract Integration is the term given to ensuring that the different elements of an electrified
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
ELECTRICAL SAFETY Information Bulletin
ELECTRICAL SAFETY Information Bulletin January 2016 CEC-10 [rev-9] Page 1 of 8 CANADIAN ELECTRICAL CODE SUBJECT: Section 10 Grounding and Bonding Rule 10-204 Grounding Connections for Alternating-Current
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
EDS 06-0017 CUSTOMER LV INSTALLATION EARTHING DESIGN
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 06-0017 ENGINEERING DESIGN STANDARD EDS 06-0017 CUSTOMER LV INSTALLATION EARTHING DESIGN Network(s):
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,
Section 559 luminaires and lighting installations An overview by Geoff Cronshaw
1 Section 559 luminaires and lighting installations An overview by Geoff Cronshaw SECTION 559 (of BS 7671:2008) luminaires and lighting installations is a new series of Regulations giving particular requirements
Candidate Self-Assessment Checklist
General Information This is a compulsory document which must be completed by all candidates due to undertake the AM2 Assessment of Occupational Competence and provided to the assessment centre prior to
AS/NZS 3000:2007 Amendment 2
AS/NZS 3000:2007 Amendment 2 Published 14 December 2012 Under Victorian legislation the day a revised standard is published it becomes the requirement. The aim of this document is to highlight the important
ELECTRICIAN S GUIDE TO EMERGENCY LIGHTING. Fully updated to BS 5266-1:2011. electrician s guide
ELECTRICIAN S GUIDE TO EMERGENCY LIGHTING Fully updated to BS 5266-1:2011 electrician s guide Published by The Institution of Engineering and Technology, London, United Kingdom The Institution of Engineering
The Application of Circuit Breakers to Reduce Downtime in Datacentres
The Application of Circuit Breakers to Reduce Downtime in Datacentres Tim Campbell BEng MIET. Marketing Manager, Terasaki Electric (Europe) Ltd. Abstract Circuit breakers fulfil several functions in the
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
How To Understand The Electrical Power Supply Of A Power Supply System
17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder
Fire Protection Notice No. 9 ELECTRICAL SAFETY
Fire Protection Notice No. 9 ELECTRICAL SAFETY Because electricity is one of the most controllable forms of energy it can also be one of the safest. But, as industry and commerce draw ever more heavily
Electric Power Distribution
Electric Power Distribution A S Pabla Consulting Engineer and Former Chief Engineer Punjab State Electricity Board McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New
Residual Current Circuit Breaker
Introduction Residual Current Circuit Breaker / ELCB The Fault current overloads and short circuits can be detected by circuit breakers like MCB s MCCB s & HRC Fuses etc. But, Circuit breakers don t detect
Guide to Low Voltage Busbar Trunking Systems Verified to BS EN 61439-6
Guide to Low Voltage Busbar Trunking Systems Verified to BS EN 61439-6 November 2014 Guide to Low Voltage Busbar Trunking Systems Verified to BS EN 61439-6 Companies involved in the preparation of this
EARTHING AND BONDING AT SECONDARY SUBSTATIONS
DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
Krav til sikkerhed for sekundære batterier og installationer af batterier Del 2: Stationære batterier
Dansk standard DS/EN 50272-2 1. udgave 2001-08-10 Krav til sikkerhed for sekundære batterier og installationer af batterier Del 2: Stationære batterier Safety requirements for secondary batteries and battery
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS
GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS 2008 EDITION www.st.gov.my CONTENTS Chapter Title Page 1. 1.1 1.2 1.3 Introduction Purpose References 4 4 5 2. Supply System 6 2.1 Electricity
FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS
1 FIRE ALARMS IN DWELLINGS By John Ware IN THE UK around 80% of all fire deaths and injuries occur in dwellings, a total of 450 to 500 deaths and 14,000 injuries per annum, according to BS 5839-6: 2004.
Sizing conductors and selecting protection devices
Sizing conductors and selecting protection devices 04 PowEr guide 2009 / BOOk 04 INTRO Careful selection of the sizes of the conductors in wiring systems and the characteristics of protection devices will
IEC 61439-1 & 2 standard. The reference for safe and reliable LV switchboards
IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC
RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62305-3 Edition 2.0 2010-12 colour inside Protection against lightning Part 3: Physical damage to structures and life hazard INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE
B-1 Buildings & Service Maintenance
B-1 Buildings & Service Maintenance B-1 Buildings & Service Maintenance SAFETY, HEALTH AND ENVIRONMENTAL POLICY: B-1 DATE OF ISSUE: AUGUST 1994. BUILDINGS AND SERVICES MAINTENANCE 1. Introduction It is
Electrical safety and you
Electrical safety and you A brief guide Introduction Electricity can kill or severely injure people and cause damage to property. Every year many accidents at work involving electric shock or burns are
MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing
MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing Release: 1 MEM10019 Select circuit protection devices by type and rating, fit to switchboards and
Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens.
Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany www.siemens.com/energy For questions on power transmission and distribution, please contact
NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers
NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers A market position paper from the experts in Business-Critical Continuity TM Executive Summary Electrocutions are the fourth
IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
xl 3 configurable assemblies IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES XL 3 configurable assemblies guide to migration from IEC 60439 to IEC 61439
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance
Annex I To Loughborough University (LU) Facilities Management (FM) Health and Safety Policy High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance 1. Introduction a. These Safety
Heading FACT SHEET. Overview. www.safeworkaustralia.gov.au
ELECTRICAL RISKS AT THE WORKPLACE Heading FACT SHEET Overview This fact sheet provides general guidance for persons conducting a business or undertaking (PCBUs) and workers on managing electrical risks
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE ET 215:2008 ELECTRO-TECHNICAL COUNCIL OF IRELAND 2008 Page 1 of 6 Published by
Electrical safety Dwellings
The Electrical safety Dwellings APPROVED DOCUMENT P1 P Design and installation of electrical installations 2013 edition for use in England* Main changes in the 2013 edition This approved document supports
FREQUENTLY ASKED QUESTIONS
September 2011 FREQUENTLY ASKED QUESTIONS Wiring Rules The new edition of the Australian/New Zealand Standard for Wiring Rules (AS/NZS 3000:2007) was released in November 2007 and revised by Amendment
Electrical Grounding. Appendix C
Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment
Screened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
Utilities and existing services
Construction Services Building standards for mechanical and electrical installations Utilities and existing services October 2012 Directorate: Environment Construction Services - Building standards for