VariTrane VAV Terminal Unit. Single-Duct Series Fan-Powered Parallel Fan-Powered

Size: px
Start display at page:

Download "VariTrane VAV Terminal Unit. Single-Duct Series Fan-Powered Parallel Fan-Powered"

Transcription

1 VariTrane VV Terminal Unit Single-uct Series Fan-Powered Parallel Fan-Powered

2 Contents VV System Overview VariTrane VV Terminal Unit Overview Model escription Single-uct Terminal Units Model escription Fan-Powered Terminal Units Performance ata Single-uct Terminal Units Performance ata Series Fan-Powered Terminal Units Performance ata Parallel Fan-Powered Terminal Units

3 VV System Overview System Introduction In a Variable ir Volume (VV) system, air delivery volume varies directly with the changing cooling or heating load, thus saving energy at part load conditions. nother benefit that makes VV a popular choice in VC design is its capability to control temperature in multiple zones. Compared to conventional constant volume system, VV system has multiple VV terminal boxes each serving a zone controlling air flow to that zone and maintaining the set-point temperature. Trane leads in VV technology with its innovative range of VariTrane units (Single-duct and Fan-powered types) that are designed for diverse applications and environments. pplications include office space, hospitals, hotels, retail stores, malls and educational facilities. VariTrane provides the most reliable and flexible products available, further enhanced by Trane C controls in implementing systems-level control strategies like ventilation reset and Static Pressure Optimization to improve systems performance and efficiency. VV System Features and enefits VV systems have the following features and benefits: conditioning systems, VV systems can utilize the outdoor fresh air as much as possible during transitional seasons, which not only saves energy consumption, but also improves indoor air quality. It is estimated that over 30% of the annual energy consumption can be saved and 0-30% of total equipment capacity can be reduced by using VV system.. Improved Indoor ir Quality and Comfort ith the integrated C control, VariTrane VV terminal units can keep room temperature and air volume within the pre-set range per actual cooling or heating load requirement and enhance control accuracy of the terminal unit. It allows room temperature to be adjusted per application requirement. Supply air of VV system can be remote and centralized controlled to improve the system efficiency and room air quality. 3. Reliable Operation, Simple Construction VV system is an all-air system. There is no water piping passing through the ceiling of the room, which can avoid problems such as condensation, water leakage and bacteria breeding which may happen in the fan coil system. In addition, VariTrane VV boxes have simple casing construction, which makes installation simple and easy. 4. Flexible System Renovation always occurs in modern buildings. y using flexible duct connection, modification of VariTrane VV terminal unit position can be done according to the room partition and requirement with minimum field modification cost, labor and time. 5. Compatible System VV systems can be integrated with other air conditioning systems to optimize performance efficiency. For example, when integrated with ice storage system, the application of cold air distribution can reduce the initial investment of ice storage system effectively; when integrated with heat pump system it can reduce the initial investment, reducing the noise level by installing several water heat pumps in central location and avoid costly installation of heat pump at each floor. 6. Easy to get integrated with uilding utomation () system VV systems can be integrated to system via C control. System optimization and monitoring of the whole system can be achieved by computerized control. VV System Structure typical VV System consists of:.ir handling units.ir duct system 3.VariTrane VV terminal nuit. Economical Operation VV systems can change the supply air volume according to the cooling and heating load variation to enable the cooling, heating capacity and fan power to meet actual load requirement. Therefore, the system energy consumption can be significantly reduced. Meanwhile, if compared with traditional air User management VV System Schematic ir supply duct ir return duct Communication cable 3

4 VV System Overview System Control Introduction The VariTrane VV box can be connected to Trane s uilding utomation System through two types of control systems. orking station (Optional) ial-up connection or Ethernet/IP connection CU Tracer System In Tracer, the work station using Tracer Summit software monitors the whole system and has many functions such as operating parameter setting, data acquisition, alarming, reports, clock, etc. The uilding control Unit (CU) provides control logic for the whole system and coordinates the operation between equipment level controllers such as MP58 and VV controllers. VV controllers are connected to each other by using RS485, and then connected to CU. The whole control system structure is simple, compatible and designed to accommodate future extension requirements. In addition, using ontalk C controllers, VariTrane VV terminal units can be connected to third party control systems which have ontalk protocol. Tracker system In Tracker, the work station is connected to a Tracker controller. It acquires equipment status, system data information, control command and monitors the system equipment. The Tracker controller provides control logic for the whole system. It coordinates the rooftop equipment (Voyager) & VariTrane VV terminal unit control through the CCP (central control panel). One Tracker controller can be connected to several CCPs, and each CCP is connected to one rooftop unit (Voyager) and several VariTrane VV boxes. Inter communication is possible between CCPs. ll equipment connections in the system are PnP (plug and play), making it convenient for installation and application. VariTrane VV terminal unit VariTrane VV terminal unit Zone sensor Voyager III VV RTU ork station (Optional) ial-up connection or Ethernet/IP connection VariTrac CCP VariTrane VV terminal unit VariTrane VV terminal unit Voyager III VV RTU Tracker controller VariTrac CCP Zone sensor Zone sensor Zone sensor Zone sensor VV system VV system Zone sensor VariTrane VV terminal unit VV system MP58 U VariTrane VV terminal unit 4

5 VariTrane VV Terminal Unit Overview VV Terminal Unit Classification VV terminal unit controls the air valve opening and regulates the air volume in the room by measuring the temperature difference between room and set point. There are two basic working principles of a VV box: pressure-dependent and pressure-independent. pressure-dependent VV control scheme uses the space temperature sensor to control the position of the modulating device directly. The actual airflow delivered to the space depends on the duct system static pressure at the inlet of the terminal unit. lthough the space temperature sensor will continually correct the position of the modulating device, the response can be sluggish and cause unacceptable temperature variations within the space. In contrast, a pressure-independent VV control scheme controls the actual volume of primary air that flows to the space. n airflow-measuring device on the terminal unit makes it possible. The position of the modulation device is not directly controlled and is basically a by-product of regulating the airflow through the unit. ecause the airflow delivered to the space is directly controlled, it is independent of inlet static pressure. Pressure-independent control increases the stability of airflow control and allows minimum and maximum airflow settings to become actual airflows rather than physical positions of the modulation device. It is clearly most popular in all VV terminal unit controls. VV terminal VV terminal ir intake ir outgoing ir intake ir outgoing ir valve Flow ring ir valve Temperature sensor Controller/air valve drive Controller/air valve drive/differential pressure transmitter Temperature sensor Pressure-dependent Pressure-independent There are three basic types of VariTrane VV terminal units, Single-duct (without fan), Series Fan-Powered and Parallel Fan-Powered. Single-duct Series fan-powered Parallel fan-powered 5

6 VariTrane VV Terminal Unit Overview Features and enefits Flow ring: ocated closely in front of the air valve, it can measure air volume accurately Metal encapsulated edge: prevents cut fibers of the insulating plate falling off, and avoids erosion in the air stream by foreign matter Controller: C controller developed by Trane, perfectly matches with other Trane products. ir valve actuator: Equipped with position indicator Interlocking panel: Smooth surface, ruggedness and rigidity are assured with Trane s interlocking panel construction ir valve: It enables air flow passing through the flow ring evenly while changing the air volume Energy Efficiency VV systems can save energy significantly, comply with ventilation requirements, and provide reliable and personalized occupant control. Energy saving features of VariTrane VV terminal units include:. System strategies like Ventilation Reset, and Static Pressure Optimization, etc. Night setback 3. Occupied/unoccupied control 4. emand controlled ventilation 5. Earthise System utilizing low temperature air and system energy optimization. dvanced Control ith years of working experience and understanding of VV system characteristic, Trane has developed a reliable C controller for VV system which has unique functions:. dvanced system integration VariTrane VV terminal unit C controller uses pressure-independent control mode, which can obtain precise air valve opening by doing two-time PI calculation according to the temperature and air flow to control air volume accurately and provide excellent indoor air quality and comfort control. It can also be integrated with Trane Tracer Summit uilding utomation System. It is the most advanced VV control system in the field. This system has a series of unique control modes such as fresh air volume / ventilation reset, static pressure optimization control which can meet the current industry regulations and standards, able to adjust air duct static pressure effectively and reduce energy consumption of the fan to improve the whole VV system efficiency.. Superior product quality oth VariTrane VV system terminal units and control devices are provided by Trane, which ensures the product quality, system compatibility and perfect system integration. 6

7 VV Terminal Unit Overview Controls Parts and Options UCM4 is a microprocessor-based C controller using pressure-independent control mode to control the supply air volume accurately to make room temperature reach the set condition. In addition, UCM4 also has additional functions, such as optional CO sensor, wireless sensor, to fulfill various customer and application requirements. VV550/55 is a ontalk protocol-based C controller which can provide precise control to VariTrane VV terminal unit. It also has good universality and compatibility, especially in connecting to the third party uilding utomation System with ontalk protocol. ireless sensor eliminates the wiring difficulty at the field and provides more flexibility for layout and sensor positioning. Trane wireless sensor is based on wide spectrum technology, This enhances system security greatly and avoids interference problem when using different system with the same frequency in the same area. UCM4 CO sensor is used to measure CO concentration in the air, converts it into electrical signal and then transmit the signal to the controller which will reset fresh air volume accordingly to ensure indoor air quality and comfort. VV550/55 uxiliary temperature sensor helps VariTrane VV terminal unit changeover between heating and cooling mode automatically without the system controller. Terminal unit controller will compare the temperature differences between the supply air temperature provided by auxiliary temperature sensor and the room temperature provided by zone sensor. It will determine the working mode automatically according to the result without manual adjustment. ireless sensor uxiliary temperature sensor all mounted uct mounted rea sensor Model Zone sensor Occupied / Unoccupied Mode Temperature setting Internal sensor ON CNCE C

8 VariTrane Model escription Single-uct VCCT igit ~ Unit Type VC Single duct igit 3 Terminal eating Mode C None E Electric heating ot water heating igit 4 evelopment Series No. T China plant igit 5~6 imension of Primary ir Valve Inlet 05 5'' 06 6'' 08 8'' 0 0'' '' 4 4'' 6 6'' igit 7~8 Reserved 00 N/ igit 9 Reserved 0 N/ igit 0~ esign No. 0 Initial development igit ~5 Control Mode 00 Trane elec actuator only 0 C cooling only 0 C N.C. on/off water valve 03 C prop hot water valve 04 C on/off electric heat control ontalk C cooling only ontalk C N.C. on/off water valve 3 ontalk C prop hot water valve 4 ontalk C on/off electric heat control FM00 Customers supply the air valve actuator and controller by themselves igit 6 Insulation " Matte-faced '' foil faced F " ouble-wall G 3/4" Closed-cell igit 7 Reserved 0 N/ igit 8 Reserved 0 N/ igit 9 Reserved 0 N/ igit 0 Reserved 0 N/ igit ot ater Coil 0 N/ row rows igit Electric Connection eft type igit 3 Transformer 0 N/ 5VC/4V C transformer 3 30VC/4V C transformer igit 4 Power isconnect 0 N/ ith igit Power Fuse 0 N/ ith igit 6 Electric eating Voltage 0 N/ C Single-phase 0V J Three-phase 380V igit 7~9 Electric eating Power 000 N/ 00.0k 00.0k k Note: For detailed specification, refer to the electric heater information igit 30 Electric eat Stage 0 N/ stage stages 3 3 stages igit 3 Reserved 0 N/ igit 3 Reserved 0 N/ 8

9 VariTrane Model escription Fan-Powered VSCT0600P igit ~ Unit Type VP Parallel fan-powered VS Series fan-powered igit 3 Terminal eating Mode C None E Electric heating ot water heating igit 4 evelopment Series No T China plant igit 5~6 Primary ir Valve 05 5'' 06 6'' 08 8'' 0 0'' '' 4 4'' 6 6'' igit 7~8 Reserved 00 N/ igit 9 P 0SQ Q R S T U igit 0~ esign No. 0 Initial development igit ~5 Control Mode 00 Trane elec actuator only 0 C cooling only 0 C N.C. on/off water valve 03 C prop hot water valve 04 C on/off electric heat control ontalk C cooling only ontalk C N.C. on/off water valve 3 ontalk C prop hot water valve 4 ontalk C on/off electric heat control FM00 Customers supply the air valve actuator and controller by themselves igit 6 Thermal Insulation " Matte-faced '' foil faced F " ouble-wall G 3/4" Closed-cell igit 7 Motor Type Standard motor igit 8 Motor Voltage 5V/60z/P 4 30V/60z/P 5 30V/50z/P igit 9 Outlet Connection Flange connection Slip & rive igit 0 ttenuator 0 N/ ith igit ot ater Coil 0 N/ row inlet (only for parallel fan-powered) rows inlet (only for parallel fan-powered) 3 row Outlet eft 5 rows Outlet eft igit Electrical Connections left igit 3 Reserved 0 N/ igit 4 Power isconnect 0 N/ with igit Power Fuse 0 N/ with igit 6 Electric eating Voltage 0 N/ C Single-phase 0V J Three-phase 380V igit 7~9 Electric eating Power 000 N/ 00.0k 00.0k ~ ~ 00 0k Note: For detailed specification, refer to the electric heater information igit 30 Electric eat Stage 0 N/ stage stages 3 3 stages igit 3 Reserved 0 N/ igit 3 irflow Switch 0 N/ ith 9

10 Performance ata VariTrane Single-uct Performance ata ir valve Inlet diameter mm irflow range m 3 /h Min. airflow m 3 /h imension mm( ) eight (kg) VCCT single-duct terminal device (cooling only) ir Pressure rop (Pa) Single-duct VV terminal device VCT heating-water heating terminal device VCET electric heating terminal device ir valve eating coil irflow (m 3 /h) Casing Electric heater row row Note: The air pressure drops in the table refer to the pressure drops of the parts. 0

11 Performance ata VariTrane Single-uct eating Capacity of ot ater Coil (k) ir Valve 05/ 06 Coil Rows Row Row ater volume (/s) ater pressure drop (kpa) Scope Size 05 Size 06 ir volume (m 3 /h) ir Valve 08 Coil Rows Row Row ir volume (m 3 /h) ater volume ater (/s) pressure drop (kpa) ir Valve 0 Coil Rows Row Row ir volume (m 3 /h) ater volume ater (/s) pressure drop (kpa) ir Valve Coil Rows Row Row ater ir volume (m 3 /h) ater volume pressure drop (/s) (kpa)

12 Performance ata VariTrane Single-uct ir Valve 4 Coil Rows Row Row ir volume (m 3 /h) ater volume ater (/s) pressure drop (kpa) ir Valve 6 Coil Rows Row Row ir volume (m 3 /h) ater volume ater (/s) pressure drop (kpa) Note:, ET=.8 C, ET= 8. C., Capacity based on.8 C entering air temperature and 8. C entering water temperature. Refer to correction factors for different entering conditions. ctual eating capacity = ata in the above table x Temperature Conrection factor Entering water temperature minus entering air temperature ET-ET Temperature correction factor Please use the following equation to calculate the leaving air temperature and the difference between entering water temperature and leaving water temperature. K x 988 T = ET + [ M 3 / (ir volume) ] T = ET - T = [ 4.9 x / S (ater volume) ] Outlet air temperature Inlet air temperature ifference between inlet water and outlet water Inlet water Outlet water temperature temperature K

13 imensional ata VariTrane Single-uct imension for Single uct with ot ater Coil Overall dimension (mm) ir Valve Z (h) (w) Electrical control box ead for flow ring Z C ir stream ir valve 0 mm 05 is 46 Z mm mm ctuator Top view Notch connection ot water coil 05, 06 (96 mm) Other(88 mm) 40 mm ccess opening of coil 76 mm x 78 mm 0 mm lock view Rear view ir Valve without coil header with coil header imension of coil (mm) Row Row C with coil header Note: Outer diameter of coil connection for without coil head is 0mm; and Outer diameter of coil for with coil head is 0mm mm ater outlet pipe C 86 mm ater outlet pipe 9 mm C 86 mm 9mm ater outlet pipe mm 86 mm ater outlet pipe 9 mm 7 mm ir stream 98mm ir stream 98mm ir stream 98mm ir stream 98mm ater inlet pipe ater inlet pipe 9 mm ater inlet pipe 44 mm 57 mm 64 mm 0 mm 0 mm 0 mm 0 mm without coil header with coil header without coil header with coil header ater inlet pipe mm 79 mm E E C C ir stream (FIG ) ir stream (FIG ) (FIG ) (FIG ) ir stream ir stream Single row ouble row 3

14 imensional ata VariTrane Single-uct imension for Single uct with Electric eating ir Valve Overall dimension (mm) ir outlet dimension (h) (w) Electric heater control box lock view Electric eater (k) Model eating Stages 0V 380V // //3/ //3/4 6/7 - - // mm ctuator Electrical control box C ead for ir stream flow ring ir valve 0 mm 05 is 46 Z mm //3/4 9 //3/4 9 //3/4 9 //3/4 9 //4 0 //4 / /6 /4/6 8/0/ / /4/6 8/0//6 8//6/30 Notch connection 40 mm 0 mm ir stream outlet Top view Rear view eft 4

15 Performance ata VariTrane Series Fan-Powered Performance ata VSCT Series Fan-powered terminal device for cooling only VST Series Fan-Powered terminal device with hot water coil VSET Series Fan-Powered terminal device with Electric heating ir Valve Inlet diameter (mm) ir volume of fan m 3 /h ir volume range for primary air m 3 /h Overall dimension mm ( ) eight (kg) 0SQ SQ SQ SQ ot ater Coil (k) 0SQ Coil Rows Row Row ater volume (/s) ater pressure drop (kpa) ir volume (m 3 /h)

16 Performance ata VariTrane Series Fan-Powered ot ater Coil (k) - contiune / Coil Rows Row Row ater volume (/s) ater pressure drop (kpa) ir volume (m 3 /h) Coil Rows Row Row ater volume (/s) ater pressure drop ir volume (m 3 /h) (kpa) / Coil Rows Row Row ater volume (/s) ater pressure drop (kpa) ir volume (m 3 /h) Note: eaving water temperature of hot water coil T should not exceed 60 C. eating capacity is based on entering air temperature of C and entering water temperature of 8 C. Refer to correction factors different entering condifions, actual heating capacity = data in the table above temperature correction factor Entering water temperature minus entering air temperature ET-ET Correction factor y using the following equation, eaving air temperature T and difference between entering water temperature and leaving water T temperature can be calculated. K x 988 T = ET + [ M 3 / (ir volume) ] T = ET - T = [ 4.9 x / S (ater volume) ] Outlet air temperature Inlet air temperature ifference between inlet water and outlet water Entering water temperature eaving water temperature K 6

17 Performance ata VariTrane Series Fan-Powered Series Fan Curve Series 0SQ-50 z Series -50 z External Static Pressure (Pa) External Static Pressure (Pa) ir volume(m 3 /h) ir volume(m 3 /h) 00 Series -50 z Series -50 z External Static Pressure (Pa) External Static Pressure (Pa) ir volume(m 3 /h) ir volume(m 3 /h) Series -50 z Series -50 z External Static Pressure (Pa) External Static Pressure (Pa) ir volume(m 3 /h) ir volume(m 3 /h) Max. air volume Min. air volume Max. air volume for row coil Max. air volume for row coil 7

18 imensional ata VariTrane Series Fan-Powered imension for Series Fan Powered with ot ater Coil 0SQ 864 (h) (w) C E "-4" ir volume (0 mm) 6" ir volume (5 mm) Flow Ring Tubing Primary air ir volume0 mm 4"-5" ir volume (65 mm) Max 479 mm Silencer (optional) Field installation Return air inlet Filter mm Coil ccess 76 mm x 78 mm ot water coil E 76 mm Coil connection Top view ir outlet Max 40 mm Filter Size (standard configuration) 0SQ 356 mm x 356 mm x 5 mm mm x mm x 5 mm mm x mm x 5 mm Max 87 mm C Rear view 8

19 imensional ata VariTrane Series Fan-Powered imension for ot ater Coil imension of coil (mm) 0SQ Row Row ater pipe - outlet ater pipe - outlet 98 mm ir stream 98 mm ccess panel ccess panel 86 mm 9 mm 86 mm 9 mm ater pipe - inlet 9 mm 5 mm ater pipe - inlet 9

20 imensional ata VariTrane Series Fan-Powered imension for Series Fan-Powered with Electric eating 0SQ 864 Overall dimension (mm) ir outlet dimension (h) (w) C E "-4" ir volume (0 mm) 6" ir volume (5 mm) Flow Ring Tubing Primary air 5" ir volume (65 mm) ir volume 0 mm Silencer (optional) Field installation Silencer (optional) Field installation 479 mm Return air inlet Filter mm 0SQ fan mm - fan 5mm - fan 5mm ctuator, controller and electrical controls of the fan 76 mm E Electric heater Top view Electric eater (k) 57 mm ir outlet Model 0SQ eating Stages 0V 380V //3/4 6 //3/4 //3/4 6 //3/4 //3/4 /0 //3/4 8/0//4 Max 40 mm Max 87 mm C 0SQ fan 38mm - fan 38mm - fan 76mm //3/4 /4/ 0//4/6 //3/4 /4/ 0//4/6/0 Rear view //3/4 /4/ 0//6/0 Filter Size (standard configuration) 0SQ 356 mm x 356 mm x 5 mm mm x mm x 5 mm mm x mm x 5 mm 0

21 Performance ata VariTrane Parallel Fan-Powered Performance ata VPCT Parallel Fan-Powered terminal device for cooling only VPT Parallel Fan-Powered terminal device with hot water coil VPET Parallel Fan-Powered terminal device with electric heating ir valve Inlet diameter (mm) ir volume of fan m 3 /h ir volume range for primary air m 3 /h Overall dimension mm ( ) eight (kg) 0SQ SQ SQ SQ

22 Performance ata VariTrane Parallel Fan-Powered ot ater Coil Performance ata (k) 0SQ Coil Rows Row Row ater volume (/s) ater pressure drop (kpa) ir volume (m 3 /h) / / Coil Rows Row Row ater ater volume pressure drop ir volume (m 3 /h) (/s) (kpa) Coil Rows / Row Row ater volume ater pressure drop ir volume (m 3 /h) (/s) (kpa) Note: eaving water temperature of hot water coil T should not exceed 60 C. eating capacity is based on entering air temperature of C and entering water temperature of 8 C. Refer to correction factors for different entering condifions, actual heating capacity = data in the table above temperature correction factor In case the data required by customer exceeds the range in the table, please contact our technical support. Entering water temperature minus entering air temperature ET-ET Correction factor y using the following equation, eaving air temperature T and difference between entering water temperature and outlet water temperature T can be calculated. K x 988 T = ET + [ M 3 / (ir volume) ] T = ET - T = [ 4.9 x / S (ater volume) ] Outlet air temperature Inlet air temperature ifference between inlet water and outlet water Entering water temperature eaving water temperature K

23 Performance ata VariTrane Parallel Fan-Powered Parallel Fan Curve 70 Parallel 0SQ-50 z 85 Parallel -50 z External Static Pressure (Pa) External Static Pressure (Pa) ir volume(m 3 /h) ir volume(m 3 /h) 85 Parallel -50 z 65 Parallel -50 z External Static Pressure (Pa) External Static Pressure (Pa) ir volume(m 3 /h) ir volume(m 3 /h) Parallel -50 z Parallel -50 z External Static Pressure (Pa) External Static Pressure (Pa) ir volume(m 3 /h) ir volume(m 3 /h) Max. air volume Min. air volume Max. air volume for row Max. air volume for row 3

24 imensional ata VariTrane Parallel Fan-Powered imension for Parallel Fan-Powered with ot ater Coil Coil at Return ir Inlet 0SQ Overall dimension (mm) ir outlet dimension (h) (w) Silencer (optional) Field installation ctuator, controller and electrical controls of the fan ctuator, controller and electrical controls of the fan mm mm Coil connection Filter Size (standard configuration) ot water coil Return air inlet 60 mm 0SQ 356 mm x mm x 5 mm mm x mm x 5 mm mm x mm x 5 mm 6"-4" ir volume (0 mm 6" ir volume (5 mm) Flow Ring Tubing mm 5" ir volume (65 mm) Silencer (optional) Primary air Field installation 76 mm ir volume 0 mm Max 479 mm Max 40 mm mm Max 87mm ir outlet Top view Rear view 4

25 imensional ata VariTrane Parallel Fan-Powered imension for Parallel Fan-Powered ot ater Coil Coil at ir Outlet 0SQ Overall dimension (mm) ir outlet dimension (h) (w) Silencer (optional) Field installation ctuator, controller and electrical controls of the fan ctuator, controller and electrical controls of the fan mm Filter size (standard configuration) Return air inlet 0SQ 356 mm x mm x 5 mm 6"-4" ir volume (0 mm 6" ir volume (5 mm) Flow Ring Tubing mm 5" ir volume (65 mm) Primary air Silencer (optional) Field installation 76 mm mm x mm x 5 mm mm x mm x 5 mm ir volume 0 mm Max 479 mm Max 40 mm mm ir outlet 60 mm ot water coil Max 87mm mm Top view Rear view

26 imensional ata VariTrane Parallel Fan-Powered imension for ot ater Coil at ir Inlet imension of coil (mm) Row Row C C 0SQ mm ater pipe - outlet C 9 mm ater pipe - outlet ir stream ir stream ater pipe - inlet 9 mm ater pipe - inlet 50mm C imension for ot ater Coil at ir Outlet imension of coil (mm) Row Row C 0SQ ater pipe - outlet ater pipe - outlet 5 mm 98 mm ir stream 98 mm ir stream ccess panel 64 mm ccess panel ater pipe - inlet ater pipe - inlet 86 mm 86 mm 9 mm 50mm C 6

27 imensional ata VariTrane Parallel Fan-Powered imension of Parallel Fan-Powered with eater Overall dimension (mm) 0SQ ir outlet dimension (h) (w) 356 ctuator, controller and electrical controls of the fan Silencer (optional) Field installation ctuator, controller and electrical controls of the fan mm Return air inlet Filter Size (standard configuration) mm 0SQ 356 mm x mm x 5 mm 0mm Flow Ring Tubing 5" ir volume (65 mm) Primary air ir volume 0 mm Silencer (optional) Field installation 76 mm mm x mm x 5 mm mm x mm x 5 mm Max 479 mm Max 40 mm mm 559 mm Terminal box Electric heater 5 mm Top view Max87mm ir outlet Rear view Outline Schematic of Electrical Control ox Electric eater (k) ir stream ir stream Model eating stages 0V 380V 49 mm 7 mm ir volume 65 mm ctuator 65 mm 40 mm ir volume E 0SQ //3 - //3/4 //3/4 //3/4 //3/4 //3/4 //3 - //3/4 //4/6 8/0/ //4/6 8/0//4 //4/6 8/0/ /4/ 0//4/6 Control type FM00 0SQ Fan model E 7

28 iterature Order Number ate Supersedes VV-PRC00-EN October 008 March 008 For more information, contact your local Trane office or us at Trane has a policy of continuous product and data improvement and reserves the right to change design specific ations without notice.

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

Fan-Powered Parallel

Fan-Powered Parallel Table of Contents Model Number Description FPP 2 3 Service Model Number Description FPP 4 Selection Procedure FPP 5 7 General Data Valve/Controller Airflow Guidelines FPP 8 Performance Data Pressure Requirements

More information

3466 Building Energy Management Training Systems

3466 Building Energy Management Training Systems 3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

Controller Operator Guide. VariTrac TM Central Control Panel VAV-SVU01A-EN

Controller Operator Guide. VariTrac TM Central Control Panel VAV-SVU01A-EN Controller Operator Guide VariTrac TM Central Control Panel VariTrac Central Control Panel Operation Guide This guide and the information in it are the property of American Standard Inc. and shall not

More information

CGC s Hybrid System Loop Control

CGC s Hybrid System Loop Control verview The CGC Group Hybrid Heat Pump System does NT operate with the same fluid loop temperatures as a conventional reversing Water Source Heat Pump system. The CGC system differs from a WSHP system

More information

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size

More information

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free... Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system

More information

Chilled Water Fan Coil Unit

Chilled Water Fan Coil Unit Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

MovinCool Office Pro Series. The Portable Spot Cooling Solution

MovinCool Office Pro Series. The Portable Spot Cooling Solution MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Topvex SX/C, Topvex TX/C. Air Handling Unit

Topvex SX/C, Topvex TX/C. Air Handling Unit Air Handling Unit Document in original language 131677-EN_GB 23-12-2015 A001 Contents 1 Declaration of Conformity... 1 2 Warnings... 2 3 Product information... 2 3.1 General... 2 3.2 Technical data...

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

AIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

The ABB i-bus KNX Room Master Concept Your first step into the KNX world The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Delivering exceptional performance and Ecovalue. Ecocent

Delivering exceptional performance and Ecovalue. Ecocent 1 Delivering exceptional performance and Ecovalue. Ecocent 2 The Ecocent Hot Water System As the cost of providing heating and hot water continues to increase, homes and businesses are seeking out more

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14 Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Charge Controller CC611/CC612 Preliminary datasheet

Charge Controller CC611/CC612 Preliminary datasheet Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

Flush-mounted room thermostats

Flush-mounted room thermostats s 3 076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600 Flush-mounted room thermostats for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment RDF300

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave

More information

GENERAL PRODUCT OVERVIEW

GENERAL PRODUCT OVERVIEW CONTROLS Pneumatic Controls comprehensive range of factory supplied, installed and calibrated controls are available for pressure independent control applications with all terminal types. Pressure dependent

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

- White Paper - Data Centre Cooling. Best Practice

- White Paper - Data Centre Cooling. Best Practice - White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

Workshop 7 PC Software - Tracker

Workshop 7 PC Software - Tracker Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09 0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

Rev. No. 0 January 5, 2009

Rev. No. 0 January 5, 2009 ENERGY & ENVIRONMENTAL ENERGY ISSUES COMMITTEE 415 Main Building Telephone (574) 631-6666 Notre Dame, Indiana Facsimile (574) 631-5883 46556 USA Energy Conservation Plan For HVAC Systems Rev. No. 0 January

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU Automatic Temperature Control Diagnosis and Repair Diagnosis of Automatic A/C Systems The most common automatic A/C system malfunctions tend to be the result of basic air conditioning problems. These problems

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer engineers volume 36 2 newsletter providing insights for today s hvac system designer energy-saving strategies for Water-Source Heat Pump Systems from the editor... Water-source heat pump (WSHP) systems

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

Product catalog UNT-PRC011-E4

Product catalog UNT-PRC011-E4 Product catalog 4-way fan coil cassettes with AC fan motor technology - model CWS sizes 00-06 4-way fan coil cassettes with EC fan motor technology - model CWE sizes 01-05 Contents Introduction 4 Main

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment The Intelligent Data Center Cooling Solution: Liebert CRV Trust the industry leader in Precision Cooling to deliver

More information

Controls for fan coil units and cassettes

Controls for fan coil units and cassettes Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

EHDC. Cooling system for Data Center and server cabinets.

EHDC. Cooling system for Data Center and server cabinets. EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

Designed for multi-injector endurance testing, the

Designed for multi-injector endurance testing, the Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room

More information

MP-4000 Alarm List (Software version 2.4.3 or later)

MP-4000 Alarm List (Software version 2.4.3 or later) Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.

More information

Variable Air Volume - VAV

Variable Air Volume - VAV Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Air conditioning, electrical testing

Air conditioning, electrical testing just a test. Air conditioning, electrical testing 01-253 Wire and component test using VAG1598 A test box Special tools and equipment VAG 1598 A test box and VAG 1598/11 adapter cable and VAG 1598/12 VAG1526

More information