ABSTRACT 1. INTRODUCTION
|
|
|
- Barry White
- 9 years ago
- Views:
Transcription
1 1 Copyright 2007 Society of Photo-Optical Instrumentation Engineers. This paper was published in SPIE Proceedings 6542, Infrared technology and Applications, XXXIII, Defense & Security Symposium, Orlando FL, It is made available as an electronic reprint with permission of SPIE. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. Variable Cold Stop for Matching IR Cameras to Multiple f-number Optics ** Nahum Gat *a, Jingyi Zhang a, Ming De Li a, Liang Chen a And Hector Gurrola b a. Opto-Knowledge Systems, Inc. (OKSI); Hamilton Ave., Torrance, CA b. US Army WSMR, White Sands Missile Range, NM ABSTRACT Cameras operating in the thermal infrared (mid-wave and long-wave IR) use a cold stop that is designed to match the exit pupil of the optics and thus avoid parasitic radiation or vignetting. For years, range operators have been using reflective telescopes, usually with photo-documentation film cameras. Along with the need to shift operation into the infrared comes a problem that (i) these telescopes do not have an exit pupil located at the IR camera cold stop, and (ii) most IR cameras have f/2 or f/4 stop, while the telescope is typically f/7 or greater. These mismatches cause a significant deterioration of the system performance and picture quality. A similar need arises when using zoom optics with IR cameras where, as the field of view changes, so does the optics f/#, creating a mismatch with the camera that has a fixed aperture. The OKSI/WSMR team has demonstrated two implementations of a patented continuous variable aperture / cold stop (CVA/CS or VariAp ) for operating IR cameras with different f/# optics. Two systems were built: (1) an optical relay assembly with an external CVA/CS, and (2) a custom pixel MWIR camera with a built in CVA/CS and the proper relay optics to match the telescope optics to the camera. The first optical relay with the VariAp is a retrofit for legacy IR cameras for operations with reflective telescopes. The camera with the built-in VariAp can function with both reflective (using an additional external relay) and refractive (with no additional relay) telescopes. The paper describes the two systems that open new possibilities in IR imaging for various ranges. Keywords: Infrared cameras, refractive telescopes, reflective telescopes, variable aperture, cold stop, f-number matching, range operations, IR zoom, multiple FOV, 3 rd Gen FLIR, targeting & navigation FLIR. 1. INTRODUCTION An f-number matched optical system and IR camera are required in order to produce an optimal image quality in the thermal IR (mid-wave or long-wave IR), Fig. 1. When the optics f/# is larger (i.e., slower) than the camera s, parasitic radiation (extraneous rays arriving not from the imaged scene but from the worm structure) reaches the image plane. This radiation increases the signal count and therefore reduces the camera s dynamic range (by filling the pixel well), and it adds to the FPA shot noise. When the optics f/# is smaller (i.e., faster) than the camera s, the aperture in the camera stops down the radiance level that reaches the image plane, and thus cuts down useful signal. As a rule, anything that the FPA can see other than the optical surfaces must be cold. For these reasons IR lenses are designed with an exit pupil located outside the lens, inside the vacuum enclosure (behind the camera window), that matches the position of the camera cold stop that is located on the cold radiation shield. An f/# matched system does not waste signal, nor suffers from parasitic signal. IR lenses do not use an iris built into the lens in order to control the f/# (as in conventional photography visible light lenses) since a warm iris would be a source of parasitic radiation. Moreover, it would be quite expensive to build IR lenses with internal iris, where the entire assembly is cooled to eliminate the parasitic signal. Hence the solution in use by industry is a camera that has an effective cold iris (a fixed size cold stop) to which the lens pupil is matched. In order * [email protected]; Phone: ; Fax ; ** OKSI and WSMR do not endorse any of the products or manufacturers mentioned in this paper.
2 Report Documentation Page Form Approved OMB No Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE APR REPORT TYPE 3. DATES COVERED to TITLE AND SUBTITLE Variable Cold Stop for Matching IR Cameras to Multiple f-number Optics 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Opto-Knowledge Systems Inc,19805 Hamilton Avenue,Torrance,CA, PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES Proceedings SPIE, Vol. 6542, "Infrared Technology and Applications, XXXIII." Orlando, FL, April ABSTRACT Cameras operating in the thermal infrared (mid-wave and long-wave IR) use a cold stop that is designed to match the exit pupil of the optics and thus avoid parasitic radiation or vignetting. For years, range operators have been using reflective telescopes, usually with photo-documentation film cameras. Along with the need to shift operation into the infrared comes a problem that (i) these telescopes do not have an exit pupil located at the IR camera cold stop, and (ii) most IR cameras have f/2 or f/4 stop, while the telescope is typically f/7 or greater. These mismatches cause a significant deterioration of the system performance and picture quality. A similar need arises when using zoom optics with IR cameras where, as the field of view changes, so does the optics f/#, creating a mismatch with the camera that has a fixed aperture. The OKSI/WSMR team has demonstrated two implementations of a patented continuous variable aperture / cold stop (CVA/CS or VariAp ) for operating IR cameras with different f/# optics. Two systems were built: (1) an optical relay assembly with an external CVA/CS, and (2) a custom pixel MWIR camera with a built in CVA/CS and the proper relay optics to match the telescope optics to the camera. The first optical relay with the VariAp is a retrofit for legacy IR cameras for operations with reflective telescopes. The camera with the built-in VariAp can function with both reflective (using an additional external relay) and refractive (with no additional relay) telescopes. The paper describes the two systems that open new possibilities in IR imaging for various ranges. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified Same as Report (SAR) 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE PERSON
3 2 to reduce the number of camera models, most cameras are built with a cold stop of about f/2 or f/4. Lenses are thus designed and built with a pupil behind the mounting flange of the lens, with matching f/#. It is not possible to change the effective f/# of such conventional IR cameras. The situation is not as simple with reflective telescopes that are in wide use throughout the range optics community. Telescopes are not designed, nor built with an exit pupil behind the mount. Moreover, most long focal length telescopes exhibit an f/# much larger than that built in cameras. Thus mounting a reflective telescope in front of an IR camera suffers from the two problems discussed above: a mismatch in pupil position, and a mismatch in the f/#. Figure 1. F-number matched (left) and unmatched (right) optical systems. Many organizations have made a large investment over the years in long-range optics; telescopes that were designed and used with film cameras and later with CCD or CMOS cameras. In the visible portion of the spectrum, or the near and short wave IR, the primary source of signal, is reflected solar radiation or emitted radiation by bright targets. Hence, the (VIS, NIR or SWIR) camera does not have a built-in aperture stop, and the signal level is determined by the f/# of the collecting optics. The thermal radiance produced by the optics and the mounts, is negligible in the VNIR and SWIR, and the film or CCD detectors are insensitive to that spectral range anyway. Although a telescope can be recoated for the thermal IR service, as explained above, it cannot produce a proper match with an IR camera, and the system will produce non-optimal imagery There is another case where matching f/# is critical, when IR zoom lenses are used. Either continuous zoom, or fixed step zoom lenses are in service. For example, targeting and navigation pods use the IR camera with optics that may have several preset fields of views (FOV) and thus several f/#s. Since the IR camera has a fixed cold stop, such targeting /navigation FLIR systems do not function in an optimal manner at all settings. The solution addressing these issues is a variable aperture / cold stop assembly that is built into the camera and replaces the fixed aperture cold stop. For cameras that are already in use, and that use a hermetically sealed dewar and cannot be upgraded, an external CVA/CS assembly can be built. The technology was first developed by OKSI for GEN-III FLIR systems 1,2 and is now patented 3 with other patents pending. 2. THE VARIABLE APERTURE MECHANISM In principle the mechanism making the VariAp is similar to an iris in a regular lens. The difference is that the blades are (i) custom made using materials that are compatible with vacuum requirements for long life time hermetically sealed dewars, (ii) are coated with IR black coatings, i.e., exhibiting low reflectivity in the spectral range of interest, (iii) the black coatings are non-particulating so that the repeated opening and closing the aperture does not cause the shedding of small particles that may settle on the FPA, and (iv) the coatings are vacuum compatible, see Fig. 2. The actuation, opening and closing of the CVA/CS, is implemented in various ways, depending on the specific camera. Some cameras 1 Garman, J., and Gat, N. "Variable Aperture Cold Stop for Dual F/# IR Optical Systems." 2004 Meeting of the Military Sensing Symposia (MSS) on Passive Sensors, Raytheon Missile Systems, Tucson, AZ, March, Garman, J., Gat, N., Vizgaitis, J., "Dual F/Number Tactical Dewar Development." 2006 Meeting of the Military Sensing Symposia (MSS) on Passive Sensors, Orlando, FL, February Gat, N., et-al, Cryogenically cooled adjustable apertures for infrared cameras, US Patent # 7,157,706.
4 3 use a manual feedthrough micrometer to operate the aperture. In other cameras this is motorized and computer controlled (the software can be used to automatically adjust the aperture to match the optics and also as a pseudo autogain control, AGC). In hermetically sealed dewars the operation is via vacuum compatible piezo motors placed inside the vacuum enclosure (for details see references 1 thru 3). This type of CVA/CS mechanism is used in the systems described in the following sections, and have been tested for hundreds of thousands actuations over long period of time, and were also shock and vibrations tested to SADA-II specs. 3. EXTERNAL VARIABLE APERTURE In the system described in this section the following parameters were of interest. The telescope is a Cassegrain f/10.5 with a 25.4 mm diagonal image size. The camera (Indigo, Phoenix) is a fixed f/4.1 with a mm FPA diagonal. The Figure 2. CVA/CS for IR cameras mounted on a cold radiation sheild. problem thus is to design an external relay system that will effectively cold stop the telescope (and other similar telescopes) and provide the needed 1.25:1 demagnification. The external CVA/CS is built into a relay optical assembly that established a match between a telescope and the camera with a fixed cold stop, Fig. 3. The relay is designed to work with a telescope that forms an image on the left side of the relay in the figure. Lenses in groups 1 and 2 straddle the cold stop and form a 1:1 relay, with a pupil located at the CVA/CS position (stop assembly), and a secondary image is formed after lens 6. Lenses in group 3 form a 1.25:1 relay that reimages the secondary image onto the FPA to the right of lens 11, via the vacuum window, camera fixed cold stop and a cold filter. The demagnification is designed to match the image plane of the telescope with the size of the FPA. The lenses in groups 2 and 3 reimage the CVA/CS onto the camera s fixed stop. The CVA/CS is housed in a vacuum enclosure between lenses 3 and 4. The enclosure does not have windows; it uses the lenses on both sides to provide the vacuum seal. The shape of the lenses was designed specifically to provide adequate flat area to cover an O-ring seal. The cold stop is cooled with a 1W Stirling engine, Fig. 4. A manual feedthrough can be seen on the top left side of the vacuum enclosure. A worm gear calibrated with a digital dial indicator is used for operating and setting the CVA/CS to any desired and known stop size. The 11 lenses in the relay, were manufactured by and assembled at Janos Technologies, and the assembly tested for performance at Optikos. Figure 3. Optical relay with an external cold CVA/CS assembly. The relay assembly with the external CVA/CS was tested after assembly and the MTF across the FOV was found to meet the design criteria. Further tests verified that the dial indicator readout (i.e., the aperture stop) produces the
5 4 expected changes in radiance. Image quality at this point was tested only with targets placed at the image plane of the relay (in front of lens 1). Results are shown in Fig. 5. Figure 4. The vacuum enclosure with the VariAp inside (the windows in this image are used for testing the vacuum on the unit before mounting the relay lens assemblies) (left), and the complete assembled system (right). Figure 5. Performance quality tests with the external VariAp relay showing stop effect of the VariAp: as the aperture is closed, the radiance level at the FPA decreases (left), a resolution target (center), and a coin (right) placed at the image plane of the relay (telescope image location). The images were captures with a f/4.1 InSb camera from Indigo 4 (FLIR Systems). 4. CAMERA WITH A BUILT-IN VARIABLE APERTURE A MWIR camera, 1,024 1,024, 19.5 µm pixels, InSb FPA (model SB184, Santa Barbara Focalplane), 114 fps via 16 output taps, was built with an internal VariAp and a four-positions cold filter wheel. The system was designed to work both with refractive and reflective optics. In order to work with refractive optics (specifically with a 500 mm, f/1.67 DiOP lens) the camera s internal cold stop and back working distance were designed to match those of the lens. In order to work with reflective telescopes (specifically with Richie-Chretien family of telescopes made by RCOS) a custom correction lens and a relay assembly were designed and built, Figs. 6a and 6b. 4 Data courtesy of Kevin Norwood, NewTec, WSMR.
6 5 Figure 6a. A correcting lens + relay assembly designed to match the f/# of a Richie-Chretien telescope with the InSb camera with the internal CVA/CS. Figure 6b. The optical relay assembly. The RC telescope is f/9 with image plane size of mm diagonal. The FPA has a diagonal dimension of mm, and thus a 1.77:1 demagnification is desired. By introducing a demagnification, the effective focal length of the telescope changes, but this was a tradeoff between the FOV and the overall magnification. Some of the interior components of the camera, i.e., the cold filter wheel, the radiation shield and the CVA/CS can be seen in Figs. 7a and 7b. The vacuum enclosure, and the feedthrough for the CVA/CS and for the filter wheel, as well as the 5W Stirling cryocooler are shown in Fig. 7c. Figure 7a. 3D CAD model of the cold assembly showing the radiation shield, the cold filter wheel, cold stop, and getter (left), and the as-built parts (right).
7 6 Figure 7b. 3D CAD model of the cold filter wheel (left), and the as-built parts with radiation shield (right). The new camera with the built-in CVA/CS was tested both with the refractive and reflective telescopes (Figs. 8a and 8b). In Fig. 8a, the DiOP lens is mounted directly in front of the camera and the back working distance and pupil position are matched. In Fig. 8b, the RCOS telescope is seen with the field flattening / telecentric optics mounted behind it. The relay assembly is mounted onto the camera. The focusing is achieved by adjusting the distance between the camera/relay and the RC/correcting lens. The system is shown mounted on a KTM at WSMR in Fig. 8b. The performance of the complete optical system is shown in ray tracing analysis results, to be diffraction limited over the 3 to 5 µm range, Fig. 9. User s interface for manual and automated control of the VariAp was developed and the main screen shown in Fig. 10. Figure 7c. 3D CAD model of the camera assembly with a 5 W Stirling cooler (left) and the actual parts without the lid on the vacuum enclosure (right). Figure 8a. The InSb VariAp camera with a 500 mm, f/1.67 refractive lens, and an image captures with the system.
8 7 Figure 8b. The InSb VariAp camera with the relay optics, correcting lens and a Ritchie-Chretien 12.5 telescope (left), and the system on a tracker mount at WSMR (right). Figure 9. Performance of the entire RC telescope with correcting lens, relay, camera window, and filter is diffraction limited.
9 8 Figure 10. User interface and VariAp control functions. 5. HERMETICALLY SEALED DEWAR IR CAMERAS The VariAp has also been implemented in hermetically sealed FLIR cameras. 1,2 One specific implementation is shown in Fig. 11. In this case the CVA/CS is mounted over the radiation shield at the position of the fixed cold stop. The actuation mechanism is the cage structure that is designed to reduce heat conduction. Piezo motors are used to apply rotation force to the ring at the bottom of the actuation mechanism. The piezo motors are vacuum compatible and are kept at ambient temperature since conduction through the actuator was proven to be negligible. Figure 11. CVA/CS design that was implemented for FLIR systems.
10 9 6. PARASITIC RADIATION ANALYSIS A simple analysis can show the effect of parasitic radiation due to mismatched f/# between optics and camera. The signal collected by a pixel in an imaging camera, and the shot noise (for a BLIP system this is the dominant source) associated with the signal can be expressed, in electron count as: where the K parameter contains the emissivity, band pass, detector quantum efficiency, optics transmission, etc., and the solid angle is defined by the f/#. All other terms are used in their traditional representation. The change in signal S, due a small change in temperature, T is: and Equating the change in signal due to a small T to the shot noise gives the NE T = T, as: Where The signal collected by a pixel, from the scene and from the parasitic radiation is expressed as the sum of signals from the scene at temperature, T 1, and the emitting mechanical structure temperature, T 2, and the solid angles for the camera and the optics Ωc and Ωo., as: (the difference between these two angles defined how much of the structure the pixel can see ). The noise expressed as NE T, can thus be shown to be: The term in the brackets represents the mismatch in f/# and parasitic radiation. This final expression has the f/# of the optics, f 0, and the f/# of the camera, f c. When those match, the expression in the brackets goes to zero, and we get the conventional definition of NE T due to shot noise only. When f 0 /f c <1, we get stopping down (i.e., overall reduction in signal and correspondingly reduction in shot noise), and when f 0 /f c >1, we get contribution from the parasitic radiation term to the signal and the associated shot noise. Of course, even if the optics and scene are at the same temperature (T 1 =T 2 ), there still is an undesired parasitic radiation. The system NE T improves (becomes smaller) as the K term (see above), and the integration time, t, become larger. Typical theoretical results are shown in Fig. 12 for an opto-mechanical structure that is slightly wormer than the scene. In this case the NE T increases (becomes worst) as the optics f/# becomes larger (i.e., slower than the camera s). This is shown by the solid lines. The lines also indicate improvements with longer integration time. As one would expect, the situation is more severe, with the f/2.3 camera than with the f/4. For the f/4 camera, as the optics become faster than f/4, the cold stop does not allow any further reduction (improvement) in NE T, and the curve is flat.
11 10 The graph also shows what would happen if the camera equipped with a CVA/CS constantly matches the f/# of the optics, dashed lines. The NE T in such case is significantly better (lower). NEDT (Relative Scale) Integration time, ms Camera matched f/# Camera f/4.0 NEDT (Relative Scale) Integration time, ms Camera matched f/# Camera f/2.3 Optics f/# Optics f/# Figure 12. NE T for a f/4 camera (left), and f/2.3 camera (right): scene = 290K, optics (several T intg ); solid lines show camera fixed f/#; dashed lines show camera with CVA/CS, constantly matched to optics f/# (NE T is better if it is a smaller number). 7. SUMMARY In order to optimally operate thermal IR cameras with long-range telescopes, provisions must be made to (a) match the f/# of the telescope and camera, and (b) match the optics exit pupil to the position of the camera cold stop. When an IR zoom lens is used with a camera, similar needs exist for matching the zoom changing f/# with that of the camera. Without such matching arrangements, image quality suffers from parasitic radiation emitted by the worm optomechanical components that are seen by the IRFPA, or vignetting may be suffered. The concept has been demonstrated from first principles of radiometric analysis. The paper describes work under which a camera with an internal, built-in, continuous variable aperture / cold stop was developed. The camera can match the f/# of a zoom lens at any zoom position. With the addition of an external relay optical assembly, the camera can also work with reflective telescopes. The relay assembly re-images the image plane of the telescope onto the IRFPA, and also the telescope exit pupil is re-imaged onto the camera CVA/CS. In cases of legacy cameras (those with a fixed cold stop), it is still possible to operate the cameras with reflective telescopes by providing an external CVA/CS that is built into an optical relay assembly. The relay re-images the telescope image plane onto the IRFPA, and also re-images the telescope exit pupil onto the external CVA/CS, and then onto the fixed camera cold stop. This special relay extends the usefulness of legacy IR cameras for service with multiple long-range telescopes. Finally, the same technology was also adapted for hermetically sealed IR cameras. The CVA/CS is computer controlled, can be matched to changes in the FOV of the optics (such as in dual or triple FOV systems), and can also be used as an aperture stop for preventing FPA saturation when signal brightness increases momentarily. In addition to range optics, the technology has direct applications to GEN-III FLIR systems, and to targeting and navigation pods with multiple fields of view.
Dynamic IR Scene Projector Based Upon the Digital Micromirror Device
Dynamic IR Scene Projector Based Upon the Digital Micromirror Device D. Brett Beasley, Matt Bender, Jay Crosby, Tim Messer, and Daniel A. Saylor Optical Sciences Corporation www.opticalsciences.com P.O.
Integration of a passive micro-mechanical infrared sensor package with a commercial smartphone camera system
1 Integration of a passive micro-mechanical infrared sensor package with a commercial smartphone camera system Nathan Eigenfeld Abstract This report presents an integration plan for a passive micro-mechanical
INFRARED PARTS MANUAL
INFRARED PARTS MANUAL PIR325 FL65 GLOLAB CORPORATION Thank you for buying our Pyroelectric Infrared components. The goal of Glolab is to produce top quality electronic kits, products and components. All
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables
Realization of a UV fisheye hyperspectral camera
Realization of a UV fisheye hyperspectral camera Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM Outline Purpose of the instrument Required specs Hyperspectral technique Optical
OPTICAL IMAGES DUE TO LENSES AND MIRRORS *
1 OPTICAL IMAGES DUE TO LENSES AND MIRRORS * Carl E. Mungan U.S. Naval Academy, Annapolis, MD ABSTRACT The properties of real and virtual images formed by lenses and mirrors are reviewed. Key ideas are
Report Documentation Page
(c)2002 American Institute Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the
Endoscope Optics. Chapter 8. 8.1 Introduction
Chapter 8 Endoscope Optics Endoscopes are used to observe otherwise inaccessible areas within the human body either noninvasively or minimally invasively. Endoscopes have unparalleled ability to visualize
Fig.1. The DAWN spacecraft
Introduction Optical calibration of the DAWN framing cameras G. Abraham,G. Kovacs, B. Nagy Department of Mechatronics, Optics and Engineering Informatics Budapest University of Technology and Economics
Overview Presented by: Boyd L. Summers
Overview Presented by: Boyd L. Summers Systems & Software Technology Conference SSTC May 19 th, 2011 1 Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection
Thermal Imaging Test Target THERMAKIN Manufacture and Test Standard
Thermal Imaging Test Target THERMAKIN Manufacture and Test Standard June 2014 This document has been produced by CPNI as the standard for the physical design, manufacture and method of use of the Thermal
Filters for Digital Photography
Filters for Digital Photography LICHTFILTER Whether for analog or Digital Photography: The best results are achieved by using correction filters - not by digitally enhancing in a software program as once
Technical Data FLIR E40bx (incl. Wi-Fi)
Technical Data FLIR E40bx (incl. Wi-Fi) Part number: 64501-0501 Copyright 2013, FLIR Systems, Inc. All rights reserved worldwide. Names and marks appearing herein are either registered trademarks or trademarks
Using the Advancement Degree of Difficulty (AD 2 ) as an input to Risk Management
Using the Advancement Degree of Difficulty (AD 2 ) as an input to Risk Management James W. Bilbro JB Consulting International Huntsville, AL Multi-dimensional Assessment of Technology Maturity Technology
PDF Created with deskpdf PDF Writer - Trial :: http://www.docudesk.com
CCTV Lens Calculator For a quick 1/3" CCD Camera you can work out the lens required using this simple method: Distance from object multiplied by 4.8, divided by horizontal or vertical area equals the lens
Principle of Thermal Imaging
Section 8 All materials, which are above 0 degrees Kelvin (-273 degrees C), emit infrared energy. The infrared energy emitted from the measured object is converted into an electrical signal by the imaging
A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA
A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA N. Zarrinpanjeh a, F. Dadrassjavan b, H. Fattahi c * a Islamic Azad University of Qazvin - [email protected]
High Speed Infrared Cameras Enable Demanding Thermal Imaging Applications
Electrophysics Resource Center White Paper High Speed Infrared Cameras Enable Demanding Written by Josh White [email protected] www.electrophysics.com/infrared-cameras High Speed Infrared Cameras
IR Window Transmittance Temperature Dependence
IR Window Transmittance Temperature Dependence Robert P. Madding, Infrared Training Center, FLIR Systems, Inc. ABSTRACT While fluoride-type IR windows are inexpensive and have good transmittance in the
Optical System Design
Optical System Design Robert E. Fischer CEO, OPTICS 1, Incorporated Biljana Tadic-Galeb Panavision Paul R. Yoder Consultant With contributions by Ranko Galeb Bernard C.Kress, Ph.D. Stephen C. McClain,
How an electronic shutter works in a CMOS camera. First, let s review how shutters work in film cameras.
How an electronic shutter works in a CMOS camera I have been asked many times how an electronic shutter works in a CMOS camera and how it affects the camera s performance. Here s a description of the way
5.3 Cell Phone Camera
164 Chapter 5 5.3 Cell Phone Camera The next design example we discuss is a cell phone camera. These systems have become quite popular, to the point that it is often more difficult to purchase a cell phone
http://dx.doi.org/10.1117/12.906346
Stephanie Fullerton ; Keith Bennett ; Eiji Toda and Teruo Takahashi "Camera simulation engine enables efficient system optimization for super-resolution imaging", Proc. SPIE 8228, Single Molecule Spectroscopy
LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes
LBS-300 Beam Sampler for C-mount Cameras P/N SP90183, SP90184, SP90185 and SP90186 YAG Focal Spot Analysis Adapter P/N SP90187, SP90188, SP90189, SP90190, SP90191 User Notes Ophir-Spiricon Inc. 60 West
Tube Control Measurement, Sorting Modular System for Glass Tube
Tube Control Measurement, Sorting Modular System for Glass Tube Tube Control is a modular designed system of settled instruments and modules. It comprises measuring instruments for the tube dimensions,
APPLICATION NOTE. Basler racer Migration Guide. Mechanics. www.baslerweb.com. Flexible Mount Concept. Housing
62 62 APPLICATION NOTE www.baslerweb.com Basler racer Migration Guide This paper describes what to consider when replacing the Basler L100 Camera Link or the Basler runner Gigabit Ethernet (GigE) line
EF-S18-55mm f/3.5-5.6 IS II COPY ENG. Instruction
EF-S18-55mm f/3.5-5.6 IS II ENG Instruction Thank you for purchasing a Canon product. The Canon EF-S18-55mm f/3.5-5.6 IS II lens is a high-performance standard zoom lens developed for digital SLRs compatible
Flat-Field IR Mega-Pixel Lens
Flat-Field Mega-Pixel Lens Series Flat-Field Mega-Pixel Lens Flat-Field Mega-Pixel Lens 20.ver.02 E Specifications and Lineup Full MP Image Model Imager Size Mount Focal Length Aperture Range Zoom Ratio
Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration
Temperature Calibration Sources Highly accurate calibration equipment for pyrometers, thermal imaging cameras, radiometers, heatflux and spectrographic measurement sytems. Calibration sources are infrared
Expert Level Thermal Imaging Cameras
Expert Level Thermal Imaging Cameras Features & Specifications Powerful Infrared Image Integrated Digital Camera Real-Time Recording Ergonomic Viewfinder + LCD Display Accurate Measurement & Analysis Tools
THE GOCI INSTRUMENT ON COMS MISSION THE FIRST GEOSTATIONARY OCEAN COLOR IMAGER
THE GOCI INSTRUMENT ON COMS MISSION THE FIRST GEOSTATIONARY OCEAN COLOR IMAGER Topic 1 - Optical instruments for Earth / Planets surface and atmosphere study François FAURE, Astrium SAS Satellite, Toulouse,
Rodenstock Photo Optics
Rogonar Rogonar-S Rodagon Apo-Rodagon N Rodagon-WA Apo-Rodagon-D Accessories: Modular-Focus Lenses for Enlarging, CCD Photos and Video To reproduce analog photographs as pictures on paper requires two
A GPS Digital Phased Array Antenna and Receiver
A GPS Digital Phased Array Antenna and Receiver Dr. Alison Brown, Randy Silva; NAVSYS Corporation ABSTRACT NAVSYS High Gain Advanced GPS Receiver (HAGR) uses a digital beam-steering antenna array to enable
The Wide Field Cassegrain: Exploring Solution Space
The Wide Field Cassegrain: Exploring Solution Space Peter Ceravolo Ceravolo Optical Systems www.ceravolo.com [email protected] Abstract This article illustrates the use of an internal aperture stop in
EF-S18-135mm f/3.5-5.6 IS
EF-S18-135mm f/3.5-5.6 IS ENG Instruction Thank you for purchasing a Canon product. The Canon EF-S18-135mm f/3.5-5.6 IS lens is a high-performance high-magnification zoom lens equipped with an Image Stabilizer,
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
Optical Design using Fresnel Lenses
Optical Design using Fresnel Lenses Basic principles and some practical examples Arthur Davis and Frank Kühnlenz Reflexite Optical Solutions Business Abstract The fresnel lens can be used in a wide variety
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002
05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical
Chapter 6 Telescopes: Portals of Discovery. How does your eye form an image? Refraction. Example: Refraction at Sunset.
Chapter 6 Telescopes: Portals of Discovery 6.1 Eyes and Cameras: Everyday Light Sensors Our goals for learning:! How does your eye form an image?! How do we record images? How does your eye form an image?
Synthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.
Revision problem Chapter 18 problem 37 page 612 Suppose you point a pinhole camera at a 15m tall tree that is 75m away. 1 Optical Instruments Thin lens equation Refractive power Cameras The human eye Combining
EF24-105mm f/4l IS USM
EF24-105mm f/4l IS USM ENG Instruction Thank you for purchasing a Canon product. The Canon EF24-105mm f/4l IS USM lens is a high-performance standard zoom lens developed for EOS cameras. It is equipped
Blackbody Radiation References INTRODUCTION
Blackbody Radiation References 1) R.A. Serway, R.J. Beichner: Physics for Scientists and Engineers with Modern Physics, 5 th Edition, Vol. 2, Ch.40, Saunders College Publishing (A Division of Harcourt
EF-S55-250mm f/4-5.6 IS STM COPY ENG. Instructions
EF-S55-250mm f/4-5.6 IS STM ENG Instructions Thank you for purchasing a Canon product. The Canon EF-S55-250mm f/4-5.6 IS STM is a high-performance telephoto zoom lens that makes movie shooting comfortable.
Introduction to CCDs and CCD Data Calibration
Introduction to CCDs and CCD Data Calibration Dr. William Welsh San Diego State University CCD: charge coupled devices integrated circuit silicon chips that can record optical (and X-ray) light pixel =
The Basics of Scanning Electron Microscopy
The Basics of Scanning Electron Microscopy The small scanning electron microscope is easy to use because almost every variable is pre-set: the acceleration voltage is always 15kV, it has only a single
OptimizedIR in Axis cameras
Whitepaper OptimizedIR in Axis cameras Leveraging new, smart and long-life LED technology Table of contents Introduction 3 1. Why do you need ir illumination? 3 2. Built-in or stand-alone ir illumination?
Imaging techniques with refractive beam shaping optics
Imaging techniques with refractive beam shaping optics Alexander Laskin, Vadim Laskin AdlOptica GmbH, Rudower Chaussee 29, 12489 Berlin, Germany ABSTRACT Applying of the refractive beam shapers in real
Asset Management- Acquisitions
Indefinite Delivery, Indefinite Quantity (IDIQ) contracts used for these services: al, Activity & Master Plans; Land Use Analysis; Anti- Terrorism, Circulation & Space Management Studies; Encroachment
Physics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
Infrared Remote Control Receiver Module IRM-2638T
Block Diagram 1 2 3 Features High protection ability against EMI Circular lens for improved reception characteristics Line-up for various center carrier frequencies. Low voltage and low power consumption.
Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect
Objectives: PS-7.1 Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect Illustrate ways that the energy of waves is transferred by interaction with
Warning : HαT telescope must NOT be used for solar observation without additional filters. This is the user responsibility to check that his filter
For high resolution chromosphere observation and imaging in Hα band Warning : HαT telescope must NOT be used for solar observation without additional filters. This is the user responsibility to check that
WHITE PAPER. Are More Pixels Better? www.basler-ipcam.com. Resolution Does it Really Matter?
WHITE PAPER www.basler-ipcam.com Are More Pixels Better? The most frequently asked question when buying a new digital security camera is, What resolution does the camera provide? The resolution is indeed
WHITE PAPER. P-Iris. New iris control improves image quality in megapixel and HDTV network cameras.
WHITE PAPER P-Iris. New iris control improves image quality in megapixel and HDTV network cameras. Table of contents 1. Introduction 3 2. The role of an iris 3 3. Existing lens options 4 4. How P-Iris
Reflection and Refraction
Equipment Reflection and Refraction Acrylic block set, plane-concave-convex universal mirror, cork board, cork board stand, pins, flashlight, protractor, ruler, mirror worksheet, rectangular block worksheet,
Advanced Micro Ring Resonator Filter Technology
Advanced Micro Ring Resonator Filter Technology G. Lenz and C. K. Madsen Lucent Technologies, Bell Labs Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection
18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008)
R 18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment.
Telescope Types. 2009 by Keith Beadman
Telescope Types 2009 by Keith Beadman Table of Contents Introduction...2 Telescope Types...2 Refractor...3 How it works...3 Advantages...3 Disadvantages...3 Best Uses...4 Dobsonian...5 How it works...5
PTZ-35MS & PTZ-50MS. Thermal Security Cameras
PTZ-35MS & PTZ-50MS Thermal Security Cameras PTZ-35MS and PTZ-50MS multi-sensor imaging systems Multi-sensor thermal camera systems for 24/7 security applications The best thermal security cameras in the
DEFENSE CONTRACT AUDIT AGENCY
DEFENSE CONTRACT AUDIT AGENCY Fundamental Building Blocks for an Acceptable Accounting System Presented by Sue Reynaga DCAA Branch Manager San Diego Branch Office August 24, 2011 Report Documentation Page
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Simulation of Air Flow Through a Test Chamber
Simulation of Air Flow Through a Test Chamber by Gregory K. Ovrebo ARL-MR- 0680 December 2007 Approved for public release; distribution unlimited. NOTICES Disclaimers The findings in this report are not
EF70-300mm f/4-5.6 IS USM
EF70-300mm f/4-5.6 IS USM ENG Instruction Thank you for purchasing a Canon product. Dedicated to EOS cameras, the Canon EF70-300mm f/4-5.6 IS USM lens is a highperformance telephoto zoom lens equipped
Passive Millimeter-Wave Imaging and Potential Applications in Homeland Security and Aeronautics
Passive Millimeter-Wave Imaging and Potential Applications in Homeland Security and Aeronautics Magdy Attia, Ph.D. James B. Duke Distinguished Professor Chair, Computer Science & Engineering Department
Geometric Optics Converging Lenses and Mirrors Physics Lab IV
Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The
Theremino System Theremino Spectrometer Technology
Theremino System Theremino Spectrometer Technology theremino System - Theremino Spectrometer Technology - August 15, 2014 - Page 1 Operation principles By placing a digital camera with a diffraction grating
Light and its effects
Light and its effects Light and the speed of light Shadows Shadow films Pinhole camera (1) Pinhole camera (2) Reflection of light Image in a plane mirror An image in a plane mirror is: (i) the same size
Single Photon Counting Module COUNT -Series
Description Laser Components COUNT series of s has been developed to offer a unique combination of high photon detection efficiency, wide dynamic range and ease of use for photon counting applications.
Simplifying Opto- Mechanical Product Development: How a new product reduces cost, stress, and time to market
Simplifying Opto- Mechanical Product Development: How a new product reduces cost, stress, and time to market Innovation in optical design is exploding. From cell phone cameras to space telescopes, driverless
Alpy guiding User Guide. Olivier Thizy ([email protected]) François Cochard ([email protected])
Alpy guiding User Guide Olivier Thizy ([email protected]) François Cochard ([email protected]) DC0017A : april 2013 Alpy guiding module User Guide Olivier Thizy ([email protected])
Optical Blade Position Tracking System Test
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Optical Blade Position Tracking
Headquarters U.S. Air Force
Headquarters U.S. Air Force I n t e g r i t y - S e r v i c e - E x c e l l e n c e Air Force Technology Readiness Assessment (TRA) Process for Major Defense Acquisition Programs LtCol Ed Masterson Mr
An Introduction to the MTG-IRS Mission
An Introduction to the MTG-IRS Mission Stefano Gigli, EUMETSAT IRS-NWC Workshop, Eumetsat HQ, 25-0713 Summary 1. Products and Performance 2. Design Overview 3. L1 Data Organisation 2 Part 1 1. Products
THE MMT MEGACAM Focal Plane Design and Performance
THE MMT MEGACAM Focal Plane Design and Performance Brian McLeod, John Geary, Mark Ordway, Steven Amato, Maureen Conroy, and Thomas Gauron Harvard-Smithsonian Center for Astrophysics Abstract: Key words:
EF70-200mm F2.8L IS USM. Instruction
EF70-200mm F2.8L IS USM Instruction Thank you for purchasing a Canon USM lens. The Canon EF 70-200mm f/2.8l IS USM is a high-performance, telephoto zoom lens dedicated to Canon EOS cameras. It is equipped
E70 Rear-view Camera (RFK)
Table of Contents (RFK) Subject Page Introduction..................................................3 Rear-view Camera..............................................3 Input/Output...................................................4
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
Specifications for DRIVER S REAR VIEW CAMERA
Specifications for DRIVER S REAR VIEW CAMERA August 2001 Sekai Electronics Inc. 13570 Larwin Circle Santa Fe Springs CA-90670 U.S.A. General Description Introduction A camera system designed to assist
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light
1.1 The Challenge of light 1. Pythagoras' thoughts about light were proven wrong because it was impossible to see A. the light beams B. dark objects C. in the dark D. shiny objects 2. Sir Isaac Newton
ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.
1 ATOMIC SPECTRA Objective: To measure the wavelengths of visible light emitted by atomic hydrogen and verify the measured wavelengths against those predicted by quantum theory. To identify an unknown
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
YOUR PARTNER FOR THERMAL IMAGING SECURITY APPLICATIONS
YOUR PARTNER FOR THERMAL IMAGING SECURITY APPLICATIONS About Opgal Security Products OPGAL is a leading global manufacturer of innovative thermal imaging cameras and engines. For over 25 years Opgal s
White paper. In the best of light The challenges of minimum illumination
White paper In the best of light The challenges of minimum illumination Table of contents 1. Introduction 3 2. The puzzle of light sensitivity 3 3. Do not be fooled! 5 4. Making the smarter choice 6 1.
Hunting Ghosts. For the development of imaging optical STRAY LIGHT ANALYSIS IN IMAGING OPTICS
Virtual prototype of the camera lens defined in [3]. Besides the lenses we model only those mechanical parts that potentially contribute the most to stray light Hunting Ghosts STRAY LIGHT ANALYSIS IN IMAGING
INFRARED THERMAL IMAGING DEFINITIONS AND TERMS
INFRARED THERMAL IMAGING DEFINITIONS AND TERMS Following is a collection of terms and words used in the thermal imaging market that you should know and understand: ABSOLUTE TEMPERATURE SCALE - Thermodynamic
3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY
3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY Prepared by Duanjie Li, PhD & Andrea Novitsky 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard
D/N VARI-FOCAL IR CAMERA
D/N VARI-FOCAL IR CAMERA PIH-0364X/0368X/0384X/0388X W/S INSTRUCTION MANUAL IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before the unit is operated.
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.
Users Manual Model #93711. English
Users Manual Model #93711 English Congratulations on your purchase of the Celestron NexImage 5 Solar System imaging camera. Your NexImage camera comes with the following: + NexImage 5 Camera + 1.25 nose
White paper. CCD and CMOS sensor technology Technical white paper
White paper CCD and CMOS sensor technology Technical white paper Table of contents 1. Introduction to image sensors 3 2. CCD technology 4 3. CMOS technology 5 4. HDTV and megapixel sensors 6 5. Main differences
STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves
Name: Teacher: Pd. Date: STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves TEK 8.8C: Explore how different wavelengths of the electromagnetic spectrum such as light and radio waves are used to
Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.
Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ., Raleigh, NC One vital step is to choose a transfer lens matched to your
Overview of the IR channels and their applications
Ján Kaňák Slovak Hydrometeorological Institute [email protected] Overview of the IR channels and their applications EUMeTrain, 14 June 2011 Ján Kaňák, SHMÚ 1 Basics in satellite Infrared image interpretation
