An EEG-based Brain Computer Interface for Rehabilitation and Restoration of Hand Control following Stroke Using Ipsilateral Cortical Physiology
|
|
|
- Francine Goodwin
- 10 years ago
- Views:
Transcription
1 Washington University in St. Louis School of Engineering and Applied Science Electrical and Systems Engineering Department ESE 498 An EEG-based Brain Computer Interface for Rehabilitation and Restoration of Hand Control following Stroke Using Ipsilateral Cortical Physiology By Sam B. Fok, Raphael Schwartz, Charles D. Holmes Supervisor Eric Leuthardt, David Bundy, Robert Morley Submitted in Partial Fulfillment of the Requirement for the BSEE Degree, Electrical and Systems Engineering Department, School of Engineering and Applied Science, Washington University in St. Louis
2 Student Statement The authors of this report have observed and upheld all codes and ethics, including the University s Honor System, and have maintained the integrity of this course in the design and implementation of this project. 2
3 Abstract Stroke and traumatic brain injury (TBI) cause long-term, unilateral loss of motor control due to brain damage on the opposing (contralateral) side of the body. Conventional neurological therapies have been found ineffective in rehabilitating upper-limb function after stroke. Brain computer interfaces (BCIs), devices that tap directly into brain signals, show promise in providing rehabilitation but remain in research. Also, BCIs cannot work if the target signals have been eliminated due to injury. Therefore we present a novel BCI, the IpsiHand, which combines advances in neurophysiology, electronics, and rehabilitation. Recent studies show that during hand movement, the cortical hemisphere on the same (ipsilateral) side of the body as the hand also activates. IpsiHand uses electroencephalography (EEG) to record these signals and control a powered hand orthosis. The undamaged hemisphere can then control both hands, and through neural plasticity IpsiHand will strengthen ipsilateral neural pathways to enhance ipsilateral motor control. Acknowledgements We would like to especially thank Mark Wronkiewicz, Jessica Zhang, Thane Somers, and Nathan Brodell who were a part of our design team. We would like to thank Dr. Eric Leuthardt, our faculty mentor, and David Bundy, our graduate student mentor, for their guidance. We would also like to thank Joanne Rasch and the Rehabilitation Institute of St. Louis for providing consumer feedback and expert opinion on current rehabilitation, and Professors Robert Morley and Joseph Klaesner for instruction during senior design. This work is supported in part by The National Collegiate Inventors and Innovators Alliance, the Washington University School of Engineering, and Emotiv Systems. 3
4 Table of Contents Student Statement... 2 Abstract... 3 Acknowledgements... 3 List of Figures... 5 List of Tables... 5 Problem Formulation... 6 Problem Statement... 6 Problem Formulation... 6 Project Specifications... 7 Signal Acquisition... 7 Signal Processing... 7 Mechanical Output... 7 System Operation... 7 Concept Synthesis... 8 Literature Review... 8 Concept Generation... 9 Concept Reduction Detailed Engineering Analysis and Design Presentation Signal Acquisition Screening Procedure and Signal Processing Control Signal Conditioning and Output Least Mean Squares Adaptive Filter Performance Analysis Computational Analysis Mechanical Orthosis Cost Analysis Lifetime Operation Cost Hazards and Failure Analysis Conclusion
5 Works Cited List of Figures Figure 1 Differences in power spectrum during A) contralateral movements and B) ipsilateral movements during movement and rest. Note that contralateral movement shows a decrease in power at frequencies less than 35Hz and an increase in power between 60 and 120Hz whereas ipsilateral movements show a decrease in power only at frequencies below 50Hz [9]... 8 Figure 2 Concept of a BCI using ipsilateral signals to restore motor function in hemiplegic stroke survivors [10]... 9 Figure 3 Orthosis design options Figure 4 - Data acquisition Design Options Figure 5 - Structure and data flow of IpsiHand. Processing occurs in three steps: signal acquisition, signal processing, and mechanical actuation Figure 6 - Spatial location of electrodes of Emotiv EPOC headset relative to head Figure 7 - between left hand movemnet and rest across bins of electrode channel and frequency Figure 8 - Frequency spectrum of the F3 EEG electrode location during conditions of left hand movement (red curve) and conditions of rest (blue curve) Figure 9 - Topographical color maps of values for 12 Hz and 22 Hz Figure 10 - ROC curves shows classification performance using varying window lengths and thresholds Figure 11 prefabricated hand orthotic fitted with linear actuator for control of finger position List of Tables Table 1 - Classification accuracy using best threshold as determined by ROC analysis per window length Table 2 - Bill of Materials
6 Problem Formulation Problem Statement In the United States, stroke, traumatic brain injury (TBI), and spinal cord injury (SCI) are the leading causes of disability affecting over a million individuals annually [1] [2] [3]. About 900,000 individuals have reported severe trouble with hand function [4], and conventional physical therapy produces little significant improvement after 3 months post injury [5]. Loss of hand function causes a severe decrease in quality of life for affected individuals [6]. In addition, lasting disabilities result in a typical lifetime cost between $100k and $2M per patient, including inpatient care, rehabilitation, and follow-up [1] [7] [8]. The most effective therapies have patients actively controlling their limb, which is not an option in cases of severe paralysis. While BCIs promise new hope for treatment, they remain in the research stage. In addition, conventional BCIs cannot be applied to cases of brain injury since the classical motor signals in cortex contralateral to the target limb needed would be gone with the injury. Problem Formulation We addressed the problem of applying BCI technology to rehabilitation following stroke and TBI. To do this we developed a device for rehabilitation that synthesizes recent developments in neurophysiology, electronics, and physical therapy into a BCI hand orthosis. A recent study found signals associated with hand movements in cortex ipsilateral to the hand. These signals were present in cortex anterior to ipsilateral primary motor cortex and at frequencies below 40Hz [9], which are accessible via EEG. With this knowledge, these intent-to-move signals can be recorded from the cortex to control an orthosis which opens and closes a patient s hand. Tactile and proprioceptive feedback provided from this device will facilitate neural plasticity, strengthening existing and developing new neural pathways ipsilateral to the affected hand that will ultimately restore motor control. Allowing the patient to regain hand control with their thoughts alone should also provide tremendous encouragement in the rehabilitation process. Our objective is to directly recouple the intent-to-move a hand with hand motion in order to improve outcomes of recovery, reduce the lifetime cost of brain injury, and improve quality of life for those affected by stroke or TBI. 6
7 Project Specifications Our design will provide the following: Signal Acquisition EEG signal recordings at locations corresponding to the International EEG standard, specifically with locations over the motor and premotor cortex. Spectral information up to 60 Hz. Signal Processing Identification of signal features correlated with intent to open or close the hand. Extraction of the control signal from the identified electrode location and frequency band. Spatial filtering to reduce noise common to the electrode of interest and reference electrode(s). Normalization of a control signal from identified features. Communication with a linear actuator for mechanical output. An adaptive filter which adjusts the gain of the mechanical output to counteract changes in the strength of the control signal. Mechanical Output Enough force to overcome spasticity and tone imbalance in a patient s hand (up to 110 N). Graded extension and flexion of the hand. System Operation Real time operation, with latency less than 3 seconds. Signal classification with an accuracy of at least 70%. 7
8 Concept Synthesis Literature Review Previous study by Wineski, et. al., discovered differences in cortical signals during contralateral and ipsilateral movement conditions (Figure 1). Note that this study was conducted with the electrocorticography (ECoG) technique, in which electrodes are placed directly onto the surface of the brain. The spatial and temporal resolution afforded by ECoG will be unavailable with the EEG technique, which is generally limited to less than 60Hz and greater than 2cm temporal and spatial resolution, respectively [10]. Figure 2 from the same lab illustrates the concept of using ipsilateral signals in a BCI application to restore limb control. Understanding of this literature was supported by courses discussing signal processing at Washington University, such as ESE 351, Signals and Systems, ESE 482, Digital Signal Processing, and ESE 488, Signals and Systems Laboratory. Figure 1 Differences in power spectrum during A) contralateral movements and B) ipsilateral movements during movement and rest. Note that contralateral movement shows a decrease in power at frequencies less than 35Hz and an increase in power between 60 and 120Hz whereas ipsilateral movements show a decrease in power only at frequencies below 50Hz [9]. 8
9 Figure 2 Concept of a BCI using ipsilateral signals to restore motor function in hemiplegic stroke survivors [10]. Device-based therapies for rehabilitation exist for both BCI and non-bci techniques. Patent application 11/857,881 describes a Nuero-robotic System developed by Myomo, which uses weak EMG signals of a partially paralyzed stroke patient to coordinate elbow movement with a motor-driven orthosis [11]. Patent application 12/758,706 describes the system for neuromuscular reeducation developed for Hand Mentor [12]. In using EMG rather than EEG, both Myomo and Hand Mentor can only be used by patients with significant residual motor control. From BrainGate, patent application 9/991,498 describes a system that uses neurological signals to control a device, and application 11/201,283 describes associated biological interface systems and methods [13] [14]. We differentiate our device from BrainGate by using EEG rather than invasive single/multiunit recordings and by focusing on intent-to-move signals in the undamaged ipsilateral cortex. Concept Generation There are three major physical components that were considered in the design of Ipsihand: 1) the mechanical orthosis, 2) the data acquisition, and 3) the linear actuator. There is a fourth component which is the signal processor, but for this prototype there was nothing considered other than a laptop. However, it should be noted that there are considerations for the future signal processing platforms, such as microcomputers and microprocessors. For the orthosis itself, there were many options to choose from. Options for the orthosis are illustrated in Figure 3. An initially attractive option was to purchase and modify an existing 9
10 device. There exist many orthotic splints that have capabilities of joint movement or aide of joint movement. Particularly, we looked at wrist-driven orthotics. With these devices, it would be very easy to uncouple the wrist to the hand movement and replace it with a linear actuator. Other options that came about included already functional actuating orthotics, including devices implementing functional electrical stimulation. Functional electrical stimulation involves applying electrical currents to activate nerves and induce muscle contraction. Devices like this were considered primarily because they would involve less direct connections to the hand and not require the addition of a linear actuator. Orthosis Modify Existing Device Use Existing Device Wrist-Driven Orthosis Dynamic Splint Continuous Passive Motion Machine Haptic Feedback Build from Scratch Functional Electrical Stimulation Figure 3 Orthosis design options. For the data acquisiton, there were many commerical options for EEG headsets and headcaps. Single electrode headsets, such as the Neurosky Mindwave, were inexpensive and simple. Most had an accesible SDK so development would be relativaley simple. However, a downside to the simple single elctrode set up is the lack of channels. For this reason, more expensive, multiple-electrode headsets were also considers. Their advantages included the ability to do spatial filtering and accesibilty to more than one location of brain. Figure 4 shows an illustration of all of the options for data acquistion devices. 10
11 Data Acquistion Single Electrode EEG Headset Multiple Electrode EEG Headset Neurosky Mindwave Star Wars Force Trainer MindSet Standard Medical Headcap Emotiv EPOC Figure 4 - Data acquisition Design Options Finally, for the linear actuator, there were a multitude of options online for purchase. All devices performed essentially the same. The big differences from option to option were the size, power, and cost of the actuator. Concept Reduction In the choice of the orthotic itself, price became a big decision factor. Devices that already hand motor driven actuation cost well over $1500. In addition, overriding the control of the actuation would be more complex than programming a separate linear actuator. For these reasons, the wrist-driven orthosis was chosen. This orthosis, the Becker Oregon Talon TM, would eventually have the bar coupling finger movement to wrist movement removed. This bar would be replaced by the linear actuator, the Firgelli L16, which would be fastened to the back end of the orthotic. The L16 was chosen primarily because of its ease of use and its value. Finally, the Emotiv EPOC was chosen as the data acquisition device. This was for a number of reasons. The device was a low cost consumer headset, yet it had multiple electrodes, so there was 11
12 more capability for feature extraction. Additionally, the device came with an easy to use SDK which had been adapted to work with BCI2000 in a BCI2000 module. Detailed Engineering Analysis and Design Presentation Electrical fields produced by synchronous firings of neurons over large areas of the brain are recorded on the scalp. These signals are then sent to a laptop for processing. The signal is filtered to generate an output signal, which is then sent to a linear actuator. An orthosis controls the patient s finger closure with this linear actuator, so that brainwaves can control the opening and closing of the hand using a signal route that bypasses damage nerves. Figure 5 - Structure and data flow of IpsiHand. Processing occurs in three steps: signal acquisition, signal processing, and mechanical actuation. Signal Acquisition EEG signals were acquired from the subject s scalp using a dry-electrode Emotiv EPOC (Emotiv; Australia) headset with 14 electrodes located over international system positions AF3, F7, F3, FC5, T7, P7, O1, O2, P8, T8, FC6, F4, F8, and AF4 using 2 reference electrodes (Figure 6). The headset aligns, bandpass filters, and digitizes the signal at 128 Hz and transmits wirelessly to a laptop. 12
13 Figure 6 - Spatial location of electrodes of Emotiv EPOC headset relative to head Screening Procedure and Signal Processing On the laptop, signal processing was carried out in the BCI2000 framework, a development platform written primarily in C++ and MATLAB that allows rapid recording, filtering, and feature selection of brain signals [15]. Initial screening in which signals are recorded while the subject makes hand movements is used to determine the EEG features that our algorithm will use to contrast movement from rest. During this screening procedure the user alternates between periods of attempted hand movement and periods of rest. After several trials, we identify the specific electrode channels and frequency bins which consistently changed in power between hand movement and rest conditions A bipolar reference scheme, in which a signal is generated by taking the difference between the signals recorded at pairs of adjacent electrodes [16], at 6-9cm distance is used to attenuate noise and artifacts on the scalp common to pairwise electrodes. It is also used to detecting signals from a region consistent in size with the diffuse spatial characteristics of EEG signals [16]. This reference technique also makes the system resilient to variation in electrode placement, which happens simply because it is impossible to place the headset in the exact same spot for each experiment. Five electrodes are available above the frontal lobe and premotor area of the contralesional hemisphere, the location of our signal of interest. Using these 5 electrodes, all combinations of spatial reference choices can be evaluated. The coefficient of determination is used as a measure of spatial reference performance, where indicates the proportion of variability in the signal attributable to the user s hand movement. The bipolar derivation is defined, 13
14 = (1) where i = 1 5, j=1 5 refer to the electrode locations of interest and and are the voltage measurement signals from the electrode i and j respectively. Therefore, is bipolar derivation of i referenced to j. We evaluate each combination and select for the highest, =argmax( { }) (2) Once the bipolar reference has been selected, the frequency bin of width 2 Hz with the highest is then selected as the control spectrum. The bipolar spatial filtered recording is then converted to actuator control signal by BCI2000 and normalized to have a mean of zero and a unit variance. This normalized control signal is then sent to LabVIEW via a UDP port. Control Signal Conditioning and Output For each cycle, a LabVIEW (National Instruments; Austin, TX) program detected whether the control signal exceeded a threshold. This is determined by: = 0 < (1) where is the control signal from BCI2000, is the threshold of the system and is termed the condition control signal. The system is designed such that a positive signal corresponds to the hand closing and a negative signal corresponds to the hand opening. The signal is condition in this way so that a user can keep the device stationary by maintaining the signal below threshold. This conditioned control signal is then used to adjust the position of the linear actuator, and thus open or close the hand. There are two main approaches to the implementation of this: 1) the control signal reflects position or 2) the control signal reflects velocity. With the first option, the control signal would be multiplied by a gain and the product would be the position the linear actuator would go to. With the second option, the control signal would be multiplied by a gain and the product would be added to the current position. 14
15 The second option is implemented because it does not show radical changes in the position as a result of the stochastic nature of the control signal. This, in turn, makes for smoother movements of the hand. This velocity based approach can be expressed by = + (2) = 0 <0 > (3) where is the extension length of the linear actuator for iteration, is the maximum length of the linear actuator, is the gain, and is the conditioned control signal for iteration. From equation (3) we can see that the there is a limit in both directions to how much the linear actuator can open or close. Though the actuator physically cannot extend past these values, this equation is included in calculations to avoid bugs. The actuator position is then changed by writing to the actuator microcontroller via a USB port. The microcontroller then adjusts the position of the actuator via pulse-width modulation. Least Mean Squares Adaptive Filter The brain is a very mutable object. Patterns that the Ipsihand observes change from trial to trail and from subject to subject. Because of this, magnitudes of the band of interest can change from trial to trial. To counteract this, the Ipsihand implements a Least Mean Squares (LMS) adaptive filter. The LMS algorithm linearly scales the selected bipolar channel by adjusting the gain. The gain is adjusted after each trial to values which would have yielded better results in the previous trial. This is expressed as =(1 ) + (Δ ) (1) 15
16 where is the gain for the k th trial, (Δ ) defines the desired movement for that trial, is the mean value for the input signal in a given trial, and, the adaptability constant, determines the rate of adaption. Given a gain for trial k-1 and data from the trial, the gain for trial k will be a weighted average of gain from trial k-1 and a gain that would have resulted in the least amount of error for trial k-1. The weights are determined by the adaptability constant. If is 0, then there is no change from trial to trial. If is 1, the gain changes without memory of the previous gain values. Performance Analysis Our design was tested with three healthy subjects to verify the ability to use non-conventional signals from the contralesional cortex to control a hand on the same side of the body. We found : 1. Hand movement correlates with EEG signals from the contralesional hemisphere. 2. Our design was successful in using these signals to coordinate a motor-driven orthosis. Results of the screening procedure described above are shown in Figure 7 for a healthy subject. The correlation between the left hand movement condition and rest condition are evaluated using values per electrode channel (y axis) and per frequency bin (x axis). Electrodes over the left hemisphere are on the lower half of the y axis and electrodes over the right hemisphere are on the upper half of the y axis. Channels names are shown according to the EEG system [17]. Bins with high values indicate significant power difference between movement and rest conditions and as such are good candidates for control signals. Clusters (dotted red circles) of high correlation are noted around the 12Hz bins in F3 through P7 and also in channel F3 around the 22Hz bin. 16
17 R 2 Values Between Left Hand Movement and Rest AF4 R 2 F8 0.5 F4 FC6 T8 0.4 P8 O2 0.3 O1 P7 T7 0.2 FC5 F3 0.1 F7 AF Frequency (Hz) Channel Figure 7 - between left hand movemnet and rest across bins of electrode channel and frequency Power of the F3 electrode during conditions of left hand movement and conditions of rest is shown in Figure 8. Movement produces even related desynchronization (ERD) in frequency bins around 12Hz and 22Hz as physiologically expected [9] Frequency Spectrum at Electrode F3 Move Left Hand Rest Amplitude Decreased Amplitude around 12Hz Decreased Amplitude around 22Hz Frequency (Hz) Figure 8 - Frequency spectrum of the F3 EEG electrode location during conditions of left hand movement (red curve) and conditions of rest (blue curve). 17
18 The left hand side of Figure 5 shows a topographical color map of correlation values between left hand movement and rest conditions for 12Hz brainwaves. Note high, bilateral correlations are seen in the frontal cortex electrodes. On the right hand side of Figure 9, a map shows 22Hz brainwaves. High correlations are seen unilaterally in F3 electrode. The strength of correlation at 12Hz allows for differentiation between left hand movement versus rest, and the correlation at 22Hz in electrode F3 allows for distinction of left versus right hand movement. Figure 9 - Topographical color maps of values for 12 Hz and 22 Hz. Using the spectral and spatial features identified from this analysis, we selected control signals to move a cursor on a computer screen. The control signal was modulated when a subject moved, or imagined moving his hand. The modulated signal gave the subject control of 1 dimensional cursor movement, and the subject was tasked with moving the cursor to a target that randomly appeared on either side of a computer screen. Through 10 sets of trials with nonimpaired individuals we were able to achieve an 81.3% success rate for this task. We expect that with optimization of our signal detection algorithms, we can achieve even better performance as it was not uncommon to see success rates upwards of 90%. 18
19 Receiver Operator Characteristic (ROC) curves evaluated the performance of a classification scheme. They provide view of the sensitivity of a classification algorithm as a function of its specificity. After collecting a sufficient amount of data, classification is tested with a number of classification thresholds. The true positive rate (ratio of true positives to total positives) and false positive rate (ratio of false positives to total negatives) are observed. True positive rate is then plotted as a function of false positive rate so that a random guess is viewed as a straight line curve from bottom-left to top-right and perfect classification is a right angle at the top left of the figure. In Figure 10 we plot ROC curves with data from 4 different lengths of data acquisition time windows. The longer windows provide us with more power to classify our signal, but also increase the time buffer and therefore increase the latency of our system. 1 ROC curves 0.9 True positive rate (Sensitivity) Seconds 2.0 Seconds 1.0 Seconds 0.5 Seconds Random Guess False positive rate (1-Specificity) Figure 10 - ROC curves shows classification performance using varying window lengths and thresholds. 19
20 We also looked at the overall classification accuracy (ratio of true classifications to total classifications) at the best threshold for each set of data. If specificity and sensitivity are equally important, the best threshold is the one corresponding to the point on the curve closest to the topleft corner of the figure. Time Window (Seconds) Accuracy of Classification % % % % Table 1 - Classification accuracy using best threshold as determined by ROC analysis per window length In analysis of real-time operation, through 10 sets of trials with non-impaired individuals we achieved an 81.3% success rate for closing and opening the orthosis in response to a prompt, when using a 0.5 second window of acquisition time. Note that this is slightly higher than that predicted by ROC analysis for the 0.5 second time window. Computational Analysis We use an autoregressive technique to compute the Maximum Entropy Method (MEM) of spectral estimation, which uses an all pole linear filter to model the spectrum. The MEM algorithm is common in the area of EEG signal processing compared to the Fast Fourier Transform (FFT) due to its higher spectral resolution and better fitting of sharp spectral features for a time-limited signal [18], [19].The tradeoff is increased computational requirements. The narrow band isolation required to evaluate mu brain waves at Hz make the MEM a desirable choice in this circumstance. Choosing the MEM estimation method we can derive the computational requirements of our system. Our signal is sampled at 128 Hz and uses buffers of data 0.5 seconds in length (as selected by our need for near real-time operation). Our bipolar spatial reference technique requires subtraction of the reference electrode from the electrode of interest at every sample, translating to 64 operations per buffer. Each MEM spectral estimation requires M x N operations, where M is the number of samples and N is the model order being used. Model order refers to 20
21 the number of poles used in the linear filter and is directly related to the number of peaks which can appear across the estimated spectrum. A model order of 16 has been determined to suit EEG applications well [18], so a total of operations results. This gives us a total of 1,088 operations per 0.5 second buffer or 2,176 operations per second. This analysis is helpful for developing requirements towards a future microprocessor choice. Mechanical Orthosis The hand orthotic (Becker Oregon TAL100 Talon) was prefabricated to couple wrist motion to the opening and closing of the hand. This coupling mechanism was replaced with a powered linear actuator (Firgelli Miniature Linear Motion Series L16) as seen in Figure 11, shifting the control of the device to the LabVIEW algorithm. The linear actuator operates according to pulsewidth modulation (PWM) control signals received from a microcontroller. The microcontroller receives control signals from LabVIEW. Figure 11 prefabricated hand orthotic fitted with linear actuator for control of finger position 21
22 Cost Analysis The IpsiHand final design has four components: the hand orthotic (Becker Oregon Talon), the actuator to move and flex the orthotic (Firgelli model L16p), the headset (Emotiv EPOC), and the micro-computer device to decode the brain signals (Gumstix Overo Earth COM). The Talon by Becker Oregon has a retail price of $325, but a company representative stated that orders of 1,000 or more would cost $ per orthotic. We expect to contract with Becker Oregon for bulk manufacturing of the slightly modified version of the Talon hand that incorporates our linear actuator. For the actuator, a representative from Firgelli reported the device costs approximately $40 for wholesale buyers. Bulk costs of the Emotiv Epoc headset remain undisclosed, however, a conservative estimate is $175 based on the retail price. Finally, the Gumstix micro-computer device can be purchased for approximately $149 with bulk pricing. Overall, parts will come to roughly $574, with an estimated $ for assembly, quality assurance, and distribution of our final product ( Table 2). Component Supplier Item (Item No.) Cost for Prototype Hand Orthotic Linear Actuator EEG Headset (pp. 3.3) oc-bci/epoc-neuroheadset/ duct_info.php?products_id=228 duct_info.php?products_id=230 Micro- Computer Assembly, Inspection, Distribution Becker Oregon Firgelli Emotiv Systems Gumstix Talon TM (BO-TAL100-L) Cost for Production (per unit) $325 $210±$10 (Confirmed) L16 (L16-P) $112 $40 (Confirmed) EPOC $500 * $175±$75 (Estimated) Overo TM Water (GUM3503W) and Tobi (PKG30002) $149±$20 (Confirmed) $100±$50 (Estimated) Total $ $ ±$ Table 2 - Bill of Materials * The Emotiv EPOC supplied by Emotiv Systems at no charge. The prototype cost listed is the retail price. 22
23 Lifetime Operation Cost The Ipsihand is very robust. For the most part, if component were to fail, the repair cost would be the price of the component being replaced. For our calculations of lifetime operation cost, we will assume a lifetime of 5 years. For the linear actuator, the lifetime is supposed to be 20,000 strokes. Assuming a bi-weekly therapy at 2 strokes a minute for 1 hour (or 240 strokes per week) the linear actuator would last for about 83 weeks. This is about 1.6 years. So for a single patient, the linear actuator would have to be replaced about 3.2 times, a cost of $125. For the EPOC headset, the headset itself should not need replacing within the five years, however the felt pads can be damaged or lost. The gold conducting contacts can become corroded from the saline solution that makes the felt conductive. 16 replacement felt and conducting contact pairs can be purchased for $49.95 from Emotiv s website. In addition, 160 felts can be bought for $ Hazards and Failure Analysis In the early design of IpsiHand, the linear actuator back end was not set as far back as it is currently. As a result, if the actuator was extended fully, the hand would be hyper-flexed. To correct this, the actuator has been set such that when it is fully extended, the hand is closed fully and not hyper-flexed, and when the actuator is fully retracted, the hand is opened fully and not hyper-extended. It should be noted, however, that people with especially sensitive finger joints should not use this device as it may cause them discomfort when it opens fully or closes fully. This problem could be corrected by programming IpsiHand with changeable limits of extension and flexion such that the hand would stop at those limits instead of moving past them. 23
24 Conclusion Combining the discovery of motor related signals in the undamaged brain hemisphere, electronics, and advances in rehabilitation, our device provides a novel method for rehabilitation for stroke survivors. In testing, we were able to process EEG signals for real-time hand control with accuracy consistent with previous studies [20]. Recent evidence suggests that combining BCIs and orthotic devices induces neural plasticity and improves motor function [9]. Furthermore, the potential for recovery is unhampered by the severity of neural pathway injury since we circumvent the entire injured pathway and uses the brain s plasticity to generate new ones. Signal acquisition, signal processing, and mechanical control methods are established, but synthesizing them with the new technique of ipsilateral cortex recording has yet to be done. Compared to devices such as, Myomo of Neuro-robotic Systems, the Bioness H200 from Ness, and Hand Mentor from Kinetic Muscles Inc., our device facilitates plasticity most directly, is less expensive and more portable, and can be used even in cases of severe damage to neural pathways. Allowing patients to regain hand control with their thoughts will provide tremendous encouragement to continue with a therapy. Combined with IpsiHand s affordability and minimal requirements for therapist supervision, IpsiHand also makes in-home treatment a very practical possibility. Based on therapist discussions, numerous improvements to the design are planned. Currently, a laptop processes the EEG signals to be used for orthosis movement. We plan to miniaturize the processing unit onto a micro-computer to give complete portability and allow patients to go beyond rehabilitation and use the device as a replacement of hand function in daily life. In addition, we would like to expand the system s ability to adapt to spatially nonstationary signals. Implementing adaptive spatial filters or an adaptive classifier that finds the strongest correlated channel automatically and continuously would improve robustness in signal strength for a long-term out-patient orthotic. More importantly, spatial and temporal filters that remove artifacts from eye blinks, EMG, and breathing, are essential to the device performance outside of a research setting. 24
25 Works Cited [1] D Lloyd-Jones and et al., "Heart disease and stroke statistics update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee," Circulation, pp. e21-181, [2] J F Kraus and D L MacArthur, "Epidemiologic aspects of brain injury," Neurologic Clinics, vol. 14, no. 2, pp , [3] M J DeVivo, "The national spinal cord injury statistical center database," in 25th Annual SCI Model Centers OT/PT Leadership Forum, Birmingham, [4] US Census Bureau. (2005) Prevalence of Disability Among Individuals 15 Years and Older by Specific Measures of Disabilities. [Online]. [5] Henrik S Jorgensen et al., "Outcome and time course of recovery in stroke. Part II: Time course of recovery. The copenhagen stroke study," Archives of Physical Medicine and Rehabilitation, vol. 76, no. 5, pp , May [6] Lorenzo Carraro, Promoting independence following a stroke: a guide for therapists and professionals working in primary health care. Geneva: Disability and Rehabilitation team, WHO; AIFO, [7] National Institute of Neurolgical Disorders and Stroke, "Interagency head injury task force report," National Institute of Neurolgical Disorders and Stroke, [8] CE Levy and et al, "Functional MRI evidence of cortical reorganization in upper-limb stroke hemiplegia treated with constraint-induced movement therapy," Am J Phys Med Rehabil, pp. 4-12, [9] Kimberly J Wineski et al., "Unique cortical physiology associated with ipsilateral hand movements and neuroprosthetic implications," Stroke, pp , [10] E Leuthardt, G Schalk, D Moran, and J Ojemann, "The emerging world of motor neuroprosthetics: a neurosurgical perspective," Neurosurgery, vol. 58, no. 1, pp. 1-14, [11] John M McBean and Kalais N Narendran, "Powered orthotic device and method of using same," 11/857,881, September 19, [12] Edward J Koeneman, James B Koeneman, Donald E Herring, and Robert S Schultz, "System and method for neuromuscular reeducation," 12/758,706, April 12, [13] John P Donoghue, Nicholas G Hatsopoulos, Mijail D Serruya, Matthew R Fellows, and Liam Paninski, "Neurological signal decoding," 09/991,498, November 14, [14] J C Flaherty and John P Donoghue, "Biological interface systems with wireless connection and related methods," 11/201,283, August 11,
26 [15] G Schalk, D McFarland, T Hinterberger, N Bribaumer, and J Wolpaw, "BCI2000: a general-purpose braincomputer interface (BCI) system," IEEE Transactions on Biomedical Engineering, pp , [16] Dennis J McFarland, Lynn M McCane, Stephen V David, and Jonathan R Wolpaw, "Spatial filter selection for EEG-based communication," Electroencephalography and Clinical Neurophysiology, vol. 103, pp , [17] Ernst Niedermeyer and Fernando Lopes da Silva, Electroencephalography: basic principles, clinical applications, and related fields.: Lippincott Williams & Wilkins, [18] William H Press, Brian P Flanney, Saul Amo Teukolsky, and William T Vetterling, Numerical recipes Fortran 77 : the art of scientific computing. New York: Cambridge University Press, [19] User Reference: ARFilter. [Online]. [20] Jonathan R Wolpaw and Dennis J McFarland, "Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans," Proc. Natl. Acad. Sci, vol. 101, no. 51, pp , December [21] D Broetz and et al, "Combination of brain-computer interface training and goal-directed physical therpy in chronic stroke: A case report," J Neurorehab and Neural Repair, pp ,
ANIMA: Non-Conventional Interfaces in Robot Control Through Electroencephalography and Electrooculography: Motor Module
Ninth LACCEI Latin American and Caribbean Conference (LACCEI 2011), Engineering for a Smart Planet, Innovation, Information Technology and Computational Tools for Sustainable Development, August 3-5, 2011,
Potential for new technologies in clinical practice
Potential for new technologies in clinical practice International Neurorehabilitation Symposium University of Zurich Feb 12-13th 2009 Prof Jane Burridge Jane Burridge Feb 2009 Introduction Societal drivers
Neuro-rehabilitation in Stroke. Amit Kumar Neuro-Occupational Therapist
Neuro-rehabilitation in Stroke Amit Kumar Neuro-Occupational Therapist Neuro-rehabilitation A process whereby patients who suffer from impairment following neurologic diseases regain their former abilities
Brain Computer Interfaces (BCI) Communication Training of brain activity
Brain Computer Interfaces (BCI) Communication Training of brain activity Brain Computer Interfaces (BCI) picture rights: Gerwin Schalk, Wadsworth Center, NY Components of a Brain Computer Interface Applications
CHAPTER 6 PRINCIPLES OF NEURAL CIRCUITS.
CHAPTER 6 PRINCIPLES OF NEURAL CIRCUITS. 6.1. CONNECTIONS AMONG NEURONS Neurons are interconnected with one another to form circuits, much as electronic components are wired together to form a functional
Video-Based Eye Tracking
Video-Based Eye Tracking Our Experience with Advanced Stimuli Design for Eye Tracking Software A. RUFA, a G.L. MARIOTTINI, b D. PRATTICHIZZO, b D. ALESSANDRINI, b A. VICINO, b AND A. FEDERICO a a Department
Brain Computer Interface Research at the Wadsworth Center
222 IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, VOL. 8, NO. 2, JUNE 2000 [9] G. Pfurtscheller, C. Neuper, C. Andrew, and G. Edlinger, Foot and hand area mu rhythms, Int. J. Psychophysiol., vol. 26,
Statistical Analysis of Arterial Blood Pressure (ABP), Central Venous. Pressure (CVP), and Intracranial Pressure (ICP)
Statistical Analysis of Arterial Blood Pressure (ABP), Central Venous Pressure (CVP), and Intracranial Pressure (ICP) Heechang Kim, Member, IEEE Portland State University E-mail: [email protected] This
ECG SIGNAL PROCESSING AND HEART RATE FREQUENCY DETECTION METHODS
ECG SIGNAL PROCESSING AND HEART RATE FREQUENCY DETECTION METHODS J. Parak, J. Havlik Department of Circuit Theory, Faculty of Electrical Engineering Czech Technical University in Prague Abstract Digital
Clinical Neuropsychology. Recovery & Rehabilitation. Alan Sunderland School of Psychology
Clinical Neuropsychology. Recovery & Rehabilitation Alan Sunderland School of Psychology 1 The Changing Role of Clinical Neuropsychology HISTORY The Origins of Clinical Neuropsychology Emergence as a profession
CCNY. BME I5100: Biomedical Signal Processing. Linear Discrimination. Lucas C. Parra Biomedical Engineering Department City College of New York
BME I5100: Biomedical Signal Processing Linear Discrimination Lucas C. Parra Biomedical Engineering Department CCNY 1 Schedule Week 1: Introduction Linear, stationary, normal - the stuff biology is not
ESE498. Intruder Detection System
0 Washington University in St. Louis School of Engineering and Applied Science Electrical and Systems Engineering Department ESE498 Intruder Detection System By Allen Chiang, Jonathan Chu, Siwei Su Supervisor
Implementation of a 3-Dimensional Game for developing balanced Brainwave
Fifth International Conference on Software Engineering Research, Management and Applications Implementation of a 3-Dimensional Game for developing balanced Brainwave Beom-Soo Shim, Sung-Wook Lee and Jeong-Hoon
STROKE CARE NOW NETWORK CONFERENCE MAY 22, 2014
STROKE CARE NOW NETWORK CONFERENCE MAY 22, 2014 Rehabilitation Innovations in Post- Stroke Recovery Madhav Bhat, MD Fort Wayne Neurological Center DISCLOSURE Paid speaker for TEVA Neuroscience Program.
NIH 5R24 HD 050821-08
William Z. Rymer, MD, PhD Center Director Chief Scientific Officer, The Rehabilitation Institute of Chicago John G. Searle Chair in Rehabilitation Research Professor, BME, McCormick School of Engineering,
Abstract. Cycle Domain Simulator for Phase-Locked Loops
Abstract Cycle Domain Simulator for Phase-Locked Loops Norman James December 1999 As computers become faster and more complex, clock synthesis becomes critical. Due to the relatively slower bus clocks
Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 [email protected], http://www.gtec.at Building a Simulink model for real-time
SOFTWARE FOR GENERATION OF SPECTRUM COMPATIBLE TIME HISTORY
3 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, 24 Paper No. 296 SOFTWARE FOR GENERATION OF SPECTRUM COMPATIBLE TIME HISTORY ASHOK KUMAR SUMMARY One of the important
Kimberly Anderson-Erisman, PhD Director of Education University of Miami & Miami Project to Cure Paralysis
Webinar title: What is the Vibe? Vibration Therapy as a Rehabilitation Tool Presenter/presenters: Kimberly Anderson-Erisman, PhD Director of Education University of Miami & Miami Project to Cure Paralysis
Active Vibration Isolation of an Unbalanced Machine Spindle
UCRL-CONF-206108 Active Vibration Isolation of an Unbalanced Machine Spindle D. J. Hopkins, P. Geraghty August 18, 2004 American Society of Precision Engineering Annual Conference Orlando, FL, United States
Modelling, Extraction and Description of Intrinsic Cues of High Resolution Satellite Images: Independent Component Analysis based approaches
Modelling, Extraction and Description of Intrinsic Cues of High Resolution Satellite Images: Independent Component Analysis based approaches PhD Thesis by Payam Birjandi Director: Prof. Mihai Datcu Problematic
Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor
Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor Abstract This paper provides information about the NEWCARD connector and board design
Exercise and FES cycle fact sheet
Exercise and FES cycle fact sheet FES = Functional Electrical Stimulation. An electrical current is passed through paralysed muscle causing it to contract. The electrical current uses the peripheral nerves
The Use of the Lokomat System in Clinical Research
International Neurorehabilitation Symposium February 12, 2009 The Use of the Lokomat System in Clinical Research Keith Tansey, MD, PhD Director, Spinal Cord Injury Research Crawford Research Institute,
It s All in the Brain!
It s All in the Brain! Presented by: Mari Hubig, M.Ed. 0-3 Outreach Coordinator Educational Resource Center on Deafness What is the Brain? The brain is a muscle In order to grow and flourish, the brain
Classic EEG (ERPs)/ Advanced EEG. Quentin Noirhomme
Classic EEG (ERPs)/ Advanced EEG Quentin Noirhomme Outline Origins of MEEG Event related potentials Time frequency decomposition i Source reconstruction Before to start EEGlab Fieldtrip (included in spm)
This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.
This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore. Title Transcription of polyphonic signals using fast filter bank( Accepted version ) Author(s) Foo, Say Wei;
Time Domain and Frequency Domain Techniques For Multi Shaker Time Waveform Replication
Time Domain and Frequency Domain Techniques For Multi Shaker Time Waveform Replication Thomas Reilly Data Physics Corporation 1741 Technology Drive, Suite 260 San Jose, CA 95110 (408) 216-8440 This paper
The Calculation of G rms
The Calculation of G rms QualMark Corp. Neill Doertenbach The metric of G rms is typically used to specify and compare the energy in repetitive shock vibration systems. However, the method of arriving
Experiment 7: Familiarization with the Network Analyzer
Experiment 7: Familiarization with the Network Analyzer Measurements to characterize networks at high frequencies (RF and microwave frequencies) are usually done in terms of scattering parameters (S parameters).
The Detection of Neural Fatigue during intensive conditioning for football: The Potential of Transcranial Magnetic Stimulation
The Detection of Neural Fatigue during intensive conditioning for football: The Potential of Transcranial Magnetic Stimulation Carl Wells PhD Sport Science Lead, Perform, National Football Centre, St.
The accurate calibration of all detectors is crucial for the subsequent data
Chapter 4 Calibration The accurate calibration of all detectors is crucial for the subsequent data analysis. The stability of the gain and offset for energy and time calibration of all detectors involved
Data Analysis Methods: Net Station 4.1 By Peter Molfese
Data Analysis Methods: Net Station 4.1 By Peter Molfese Preparing Data for Statistics (preprocessing): 1. Rename your files to correct any typos or formatting issues. a. The General format for naming files
Functional neuroimaging. Imaging brain function in real time (not just the structure of the brain).
Functional neuroimaging Imaging brain function in real time (not just the structure of the brain). The brain is bloody & electric Blood increase in neuronal activity increase in metabolic demand for glucose
Understanding CIC Compensation Filters
Understanding CIC Compensation Filters April 2007, ver. 1.0 Application Note 455 Introduction f The cascaded integrator-comb (CIC) filter is a class of hardware-efficient linear phase finite impulse response
A Sound Analysis and Synthesis System for Generating an Instrumental Piri Song
, pp.347-354 http://dx.doi.org/10.14257/ijmue.2014.9.8.32 A Sound Analysis and Synthesis System for Generating an Instrumental Piri Song Myeongsu Kang and Jong-Myon Kim School of Electrical Engineering,
Documentation Wadsworth BCI Dataset (P300 Evoked Potentials) Data Acquired Using BCI2000's P3 Speller Paradigm (http://www.bci2000.
Documentation Wadsworth BCI Dataset (P300 Evoked Potentials) Data Acquired Using BCI2000's P3 Speller Paradigm (http://www.bci2000.org) BCI Competition III Challenge 2004 Organizer: Benjamin Blankertz
by Argyrios Stampas, MD, Carolin Dohle, MD, and Elizabeth Dominick, PT, DPT, NCS
by Argyrios Stampas, MD, Carolin Dohle, MD, and Elizabeth Dominick, PT, DPT, NCS Therapist Jennifer Metz (right) helps a patient use a body-weight support treadmill system. Up and Moving Blending dedication
Galaxy Morphological Classification
Galaxy Morphological Classification Jordan Duprey and James Kolano Abstract To solve the issue of galaxy morphological classification according to a classification scheme modelled off of the Hubble Sequence,
Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz
Author: Don LaFontaine Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz Abstract Making accurate voltage and current noise measurements on op amps in
ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1
WHAT IS AN FFT SPECTRUM ANALYZER? ANALYZER BASICS The SR760 FFT Spectrum Analyzer takes a time varying input signal, like you would see on an oscilloscope trace, and computes its frequency spectrum. Fourier's
Example #1: Controller for Frequency Modulated Spectroscopy
Progress Report Examples The following examples are drawn from past student reports, and illustrate how the general guidelines can be applied to a variety of design projects. The technical details have
TECHNICAL SPECIFICATIONS, VALIDATION, AND RESEARCH USE CONTENTS:
TECHNICAL SPECIFICATIONS, VALIDATION, AND RESEARCH USE CONTENTS: Introduction to Muse... 2 Technical Specifications... 3 Research Validation... 4 Visualizing and Recording EEG... 6 INTRODUCTION TO MUSE
RF Measurements Using a Modular Digitizer
RF Measurements Using a Modular Digitizer Modern modular digitizers, like the Spectrum M4i series PCIe digitizers, offer greater bandwidth and higher resolution at any given bandwidth than ever before.
First Year. PT7040- Clinical Skills and Examination II
First Year Summer PT7010 Anatomical Dissection for Physical Therapists This is a dissection-based, radiographic anatomical study of the spine, lower extremity, and upper extremity as related to physical
Vibrations can have an adverse effect on the accuracy of the end effector of a
EGR 315 Design Project - 1 - Executive Summary Vibrations can have an adverse effect on the accuracy of the end effector of a multiple-link robot. The ability of the machine to move to precise points scattered
Composite Video Separation Techniques
TM Composite Video Separation Techniques Application Note October 1996 AN9644 Author: Stephen G. LaJeunesse Introduction The most fundamental job of a video decoder is to separate the color from the black
Non-Data Aided Carrier Offset Compensation for SDR Implementation
Non-Data Aided Carrier Offset Compensation for SDR Implementation Anders Riis Jensen 1, Niels Terp Kjeldgaard Jørgensen 1 Kim Laugesen 1, Yannick Le Moullec 1,2 1 Department of Electronic Systems, 2 Center
Chapter 10 Introduction to Time Series Analysis
Chapter 1 Introduction to Time Series Analysis A time series is a collection of observations made sequentially in time. Examples are daily mortality counts, particulate air pollution measurements, and
Motor dysfunction 2: Spinal cord injury and subcortical motor disorders ANATOMY REVIEW: Basal Ganglia
Motor dysfunction 2: Spinal cord injury and subcortical motor disorders ANATOMY REVIEW: Basal Ganglia A group of subcortical nuclei caudate, putamen, globus pallidus Caudate & Putamen = Neostriatum caudate
3. What clinical applications of the technology do you envisage in the future? (Please try to specify a timeframe for these developments)
This response was submitted to an expert consultation held by the Nuffield Council on Bioethics on Novel neurotechnologies: intervening in the brain in February 2012. The views expressed are solely those
Application Note Noise Frequently Asked Questions
: What is? is a random signal inherent in all physical components. It directly limits the detection and processing of all information. The common form of noise is white Gaussian due to the many random
Principles of Adjustable Frequency Drives
What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable
Masters research projects. 1. Adapting Granger causality for use on EEG data.
Masters research projects 1. Adapting Granger causality for use on EEG data. Background. Granger causality is a concept introduced in the field of economy to determine which variables influence, or cause,
Electrophysiology of the expectancy process: Processing the CNV potential
Electrophysiology of the expectancy process: Processing the CNV potential *, Išgum V. ** *, Boživska L. Laboratory of Neurophysiology, Institute of Physiology, Medical Faculty, University Sv. Kiril i Metodij,
A DESIGN OF DSPIC BASED SIGNAL MONITORING AND PROCESSING SYSTEM
ISTANBUL UNIVERSITY JOURNAL OF ELECTRICAL & ELECTRONICS ENGINEERING YEAR VOLUME NUMBER : 2009 : 9 : 1 (921-927) A DESIGN OF DSPIC BASED SIGNAL MONITORING AND PROCESSING SYSTEM Salih ARSLAN 1 Koray KÖSE
Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19
Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and
Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.
Standards for Reportin ng EMG Data Author: Dr. Roberto Merletti, Politecnico di Torino, Italy The Standards for Reporting EMG Data, written by Dr. Robertoo Merletti, are endorsed by the International Society
National Stroke Association s Guide to Choosing Stroke Rehabilitation Services
National Stroke Association s Guide to Choosing Stroke Rehabilitation Services Rehabilitation, often referred to as rehab, is an important part of stroke recovery. Through rehab, you: Re-learn basic skills
Brain Maps The Sensory Homunculus
Brain Maps The Sensory Homunculus Our brains are maps. This mapping results from the way connections in the brain are ordered and arranged. The ordering of neural pathways between different parts of the
Brain Computer Interface Technology: A Review of the First International Meeting
164 IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, VOL. 8, NO. 2, JUNE 2000 Brain Computer Interface Technology: A Review of the First International Meeting Jonathan R. Wolpaw (Guest Editor), Niels Birbaumer,
B3. Short Time Fourier Transform (STFT)
B3. Short Time Fourier Transform (STFT) Objectives: Understand the concept of a time varying frequency spectrum and the spectrogram Understand the effect of different windows on the spectrogram; Understand
Cell Phone Vibration Experiment
Objective Cell Phone Vibration Experiment Most cell phones are designed to vibrate. But at what frequency do they vibrate? With an accelerometer, data acquisition and signal analysis the vibration frequency
Doctor of Philosophy (PhD) in Exercise Science specializing in Rehabilitation Sciences
Doctor of Philosophy (PhD) in Exercise Science specializing in Rehabilitation Sciences Overview PhD in Division of Rehabilitation Sciences The Ph.D. program is designed to prepare students for research
Agent Simulation of Hull s Drive Theory
Agent Simulation of Hull s Drive Theory Nick Schmansky Department of Cognitive and Neural Systems Boston University March 7, 4 Abstract A computer simulation was conducted of an agent attempting to survive
Transmittal 55 Date: MAY 5, 2006. SUBJECT: Changes Conforming to CR3648 for Therapy Services
CMS Manual System Pub 100-03 Medicare National Coverage Determinations Department of Health & Human Services (DHHS) Centers for Medicare & Medicaid Services (CMS) Transmittal 55 Date: MAY 5, 2006 Change
CLASSIFICATION OF MOTOR IMAGERY FOR BRAIN-COMPUTER INTERFACES
Poznan University of Technology Faculty of Computing and Information Science Institute of Computing Science Master s thesis CLASSIFICATION OF MOTOR IMAGERY FOR BRAIN-COMPUTER INTERFACES Piotr Szachewicz
FTIR Instrumentation
FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation
Convention Paper Presented at the 112th Convention 2002 May 10 13 Munich, Germany
Audio Engineering Society Convention Paper Presented at the 112th Convention 2002 May 10 13 Munich, Germany This convention paper has been reproduced from the author's advance manuscript, without editing,
Reflex Physiology. Dr. Ali Ebneshahidi. 2009 Ebneshahidi
Reflex Physiology Dr. Ali Ebneshahidi Reflex Physiology Reflexes are automatic, subconscious response to changes within or outside the body. a. Reflexes maintain homeostasis (autonomic reflexes) heart
Wireless Medical Telemetry Laboratory
Wireless Medical Telemetry Laboratory 0 Introduction The development of wireless medical telemetry has become an increasingly popular application in recent years. As the elderly population continues to
The Future of Rehabilitation. Matt Wilks, PT Richmond Stroke Symposium 2011
The Future of Rehabilitation Matt Wilks, PT Richmond Stroke Symposium 2011 Disclosure Information Matt Wilks, PT, Director of Therapy Innovative Practices in Stroke Rehabilitation Financial Disclosure:
Macromodels of Packages Via Scattering Data and Complex Frequency Hopping
F. G. Canavero ½, I. A. Maio ½, P. Thoma ¾ Macromodels of Packages Via Scattering Data and Complex Frequency Hopping ½ Dept. Electronics, Politecnico di Torino, Italy ¾ CST, Darmstadt, Germany Introduction
From Concept to Production in Secure Voice Communications
From Concept to Production in Secure Voice Communications Earl E. Swartzlander, Jr. Electrical and Computer Engineering Department University of Texas at Austin Austin, TX 78712 Abstract In the 1970s secure
MATRIX TECHNICAL NOTES
200 WOOD AVENUE, MIDDLESEX, NJ 08846 PHONE (732) 469-9510 FAX (732) 469-0418 MATRIX TECHNICAL NOTES MTN-107 TEST SETUP FOR THE MEASUREMENT OF X-MOD, CTB, AND CSO USING A MEAN SQUARE CIRCUIT AS A DETECTOR
QNET Experiment #06: HVAC Proportional- Integral (PI) Temperature Control Heating, Ventilation, and Air Conditioning Trainer (HVACT)
Quanser NI-ELVIS Trainer (QNET) Series: QNET Experiment #06: HVAC Proportional- Integral (PI) Temperature Control Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual Table of Contents
A comparison of radio direction-finding technologies. Paul Denisowski, Applications Engineer Rohde & Schwarz
A comparison of radio direction-finding technologies Paul Denisowski, Applications Engineer Rohde & Schwarz Topics General introduction to radiolocation Manual DF techniques Doppler DF Time difference
Structural Health Monitoring Tools (SHMTools)
Structural Health Monitoring Tools (SHMTools) Parameter Specifications LANL/UCSD Engineering Institute LA-CC-14-046 c Copyright 2014, Los Alamos National Security, LLC All rights reserved. May 30, 2014
The Development of a Pressure-based Typing Biometrics User Authentication System
The Development of a Pressure-based Typing Biometrics User Authentication System Chen Change Loy Adv. Informatics Research Group MIMOS Berhad by Assoc. Prof. Dr. Chee Peng Lim Associate Professor Sch.
Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note 1304-6
Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements Application Note 1304-6 Abstract Time domain measurements are only as accurate as the trigger signal used to acquire them. Often
D A T A M I N I N G C L A S S I F I C A T I O N
D A T A M I N I N G C L A S S I F I C A T I O N FABRICIO VOZNIKA LEO NARDO VIA NA INTRODUCTION Nowadays there is huge amount of data being collected and stored in databases everywhere across the globe.
Assessment of Camera Phone Distortion and Implications for Watermarking
Assessment of Camera Phone Distortion and Implications for Watermarking Aparna Gurijala, Alastair Reed and Eric Evans Digimarc Corporation, 9405 SW Gemini Drive, Beaverton, OR 97008, USA 1. INTRODUCTION
Telemetry in monkey neurophysiology Remote monitoring of neuronal brain signals
Telemetry in monkey neurophysiology Remote monitoring of neuronal brain signals Alexander Gail German Primate Center Göttingen, GE Thomas Recording GmbH Giessen, GE This R&D project is part of EUPRIM -
Final Year Project Progress Report. Frequency-Domain Adaptive Filtering. Myles Friel. Supervisor: Dr.Edward Jones
Final Year Project Progress Report Frequency-Domain Adaptive Filtering Myles Friel 01510401 Supervisor: Dr.Edward Jones Abstract The Final Year Project is an important part of the final year of the Electronic
High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound
High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound Ralf Bruder 1, Florian Griese 2, Floris Ernst 1, Achim Schweikard
A Novel Method to Improve Resolution of Satellite Images Using DWT and Interpolation
A Novel Method to Improve Resolution of Satellite Images Using DWT and Interpolation S.VENKATA RAMANA ¹, S. NARAYANA REDDY ² M.Tech student, Department of ECE, SVU college of Engineering, Tirupati, 517502,
Automatic Detection of Emergency Vehicles for Hearing Impaired Drivers
Automatic Detection of Emergency Vehicles for Hearing Impaired Drivers Sung-won ark and Jose Trevino Texas A&M University-Kingsville, EE/CS Department, MSC 92, Kingsville, TX 78363 TEL (36) 593-2638, FAX
EEG COHERENCE AND PHASE DELAYS: COMPARISONS BETWEEN SINGLE REFERENCE, AVERAGE REFERENCE AND CURRENT SOURCE DENSITY
Version 1, June 13, 2004 Rough Draft form We apologize while we prepare the manuscript for publication but the data are valid and the conclusions are fundamental EEG COHERENCE AND PHASE DELAYS: COMPARISONS
How To Manage A Catastrophic Injury
Report #14 CATASTROPHIC INJURIES: Paralysis, Amputation, Burns Overview: A catastrophic injury or illness usually occurs suddenly and without warning. Injuries may be considered catastrophic when they
The Anatomy of Spinal Cord Injury (SCI)
The Anatomy of Spinal Cord Injury (SCI) What is the Spinal Cord? The spinal cord is that part of your central nervous system that transmits messages between your brain and your body. The spinal cord has
AN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz
AN1200.04 Application Note: FCC Regulations for ISM Band Devices: Copyright Semtech 2006 1 of 15 www.semtech.com 1 Table of Contents 1 Table of Contents...2 1.1 Index of Figures...2 1.2 Index of Tables...2
Aircraft cabin noise synthesis for noise subjective analysis
Aircraft cabin noise synthesis for noise subjective analysis Bruno Arantes Caldeira da Silva Instituto Tecnológico de Aeronáutica São José dos Campos - SP [email protected] Cristiane Aparecida Martins
