D. Nortel WLAN 2300 Series Security Switch Installation and Basic Configuration Guide. Release 5.0. Part No. NN ( D) May 2007

Size: px
Start display at page:

Download "320656-D. Nortel WLAN 2300 Series Security Switch Installation and Basic Configuration Guide. Release 5.0. Part No. NN47250-301 (320656-D) May 2007"

Transcription

1 Part No. NN ( D) May Great America Parkway Santa Clara, CA Nortel WLAN 2300 Series Security Switch Installation and Basic Configuration Guide Release D

2 2 Copyright 2007 Nortel Networks. All rights reserved. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks. Trademarks and Service Marks *Nortel, Nortel Networks, the Nortel logo, and the Globemark are trademarks of Nortel Networks. *Microsoft, MS, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. *Adobe and Acrobat Reader are trademarks of Adobe Systems Incorporated. All other trademarks and registered trademarks are the property of their respective owners. International Regulatory Statements of Conformity for the WSSs This is to certify that the Nortel WLAN Security Switch 2300 series switches are evaluated to the international regulatory standards for electromagnetic compliance (EMC) and safety and was found to have met the requirements for the following international standards: EMC - Electromagnetic Emissions CISPR 22, Class A EMC - Electromagnetic Immunity CISPR 24 Electrical Safety IEC 60950, with CB member national deviations Further, the equipment has been certified as compliant with the national standards as detailed below. National Electromagnetic Compliance (EMC) Statements of Compliance FCC statement (USA only) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense. ICES statement (Canada only) Canadian Department of Communications Radio Interference Regulations This digital apparatus (WLAN Security Switch 2300 series switches) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications. NN ( D Version 01.02)

3 3 Règlement sur le brouillage radioélectrique du ministère des Communications Cet appareil numérique (WLAN Sécurité Changement 2300 changements de la série) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada. CE marking statement (Europe only) EN statements This is to certify that the Nortel WLAN Security Switch 2300 Series switches are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC. Conformity is declared by the application of EN Class A (CISPR 22). Warning: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take appropriate measures. Achtung: Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist. Attention: Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l utilisateur de prendre les mesures spécifiques appropriées. EN statement This is to certify that the Nortel WLAN Security Switch 2300 Series switches are shielded against the susceptibility to radio interference in accordance with the application of Council Directive 89/336/EEC. Conformity is declared by the application of EN (CISPR 24). European Union and European Free Trade Association (EFTA) notice All products labeled with the CE marking comply with the Electromagnetic Compliance (EMC) Directive (89/336/EEC) and the Low Voltage Directive (73/336/EEC) issued by the Commission of the European Community. Compliance with these directives implies comformity to the following European Norms (ENs). The equivalent international standards are listed in parenthesis. EN (CISPR 22) Electromagnetic Interference EN (IEC , -3, -4, -5, -6, -8, -11) Electromagnetic Immunity EN (IEC ) Power Line Harmonics EN (IEC ) Power Line Flicker Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

4 4 VCCI statement (Japan/Nippon only) This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) for information technology equipment. If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. BSMI statement for Wireless Security Switches 2300 Series (Taiwan only) This is a Class A product based on the standard of the Bureau of Standards, Metrology and Inspection (BSMI) CNS 13438, Class A. MIC notice (Republic of Korea only) This device has been approved for use in Business applications only per the Class A requirements of the Republic of Korea Ministry of Information and Communications (MIC). This device may not be sold for use in a non-business application. Observe the Regulatory Marking label on the back or bottom of each switch for specific certification information pertaining to this model. Each model in the WLAN Security Switch 2300 Series is approved for shipment to/usage in Korea and is labeled as such, with all appropriate text and the appropriate MIC reference number. National Safety Statements of Compliance EN statement This is to certify that the Nortel WLAN Security Switch 2300 Series switches are in compliance with the requirements of EN in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance. NN ( D Version 01.02)

5 5 NOM statement (Mexico only) The following information is provided on the devices described in this document in compliance with the safety requirements of the Norma Oficial Méxicana (NOM): Exporter: Nortel Networks 4655 Great America Parkway Santa Clara CA USA Importer: Nortel Networks de México, S.A. de C.V. Avenida Insurgentes Sur #1605 Piso 30, Oficina Col. San Jose Insurgentes Deleg-Benito Juarez México D.F Tel: Fax: Input Input: Input: Model 2350 (with external power supply) 48VDC, 830 ma, 40 W External Power Supply AC Input VAC, 1.0A, 50/60 Hz Model 2360 (Single power supply) VAC 2A 50/60Hz Model 2361 (with redundant supply) VAC 2A 50/60Hz Model 2380 (Single power supply) V 50/60 Hz 8-3.5A Model 2380 (with redundant supply) V 50/60 Hz 8-3.5A Información NOM (unicamente para México) La información siguiente se proporciona en el dispositivo o en los dispositivos descritos en este documento, en cumplimiento con los requisitos de la Norma Oficial Méxicana (NOM): Exportador: Importador: Nortel Networks, 4655 Great America Parkway Santa Clara, CA USA Nortel Networks de México, S.A. de C.V. Avenida Insurgentes Sur #1605 Piso 30, Oficina Col. San Jose Insurgentes Deleg-Benito Juarez México D.F Tel: Fax: Entrada: Modele 2350 (con suministro de corriente externo) 48VDC, 830 ma, 40 W AC el suministro de Power externo VAC, 1.0A, 50/60 Hz Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

6 6 Entrada: Entrada: Modele 2360 (solo suministro de corriente) CA V 2A 50/60Hz Modele 2361 (con suministro redundante) CA V 2A 50/60Hz Modele 2380 (solo suministro de corriente) CA V 50/60 Hz 8-3.5A Modele 2380 (con suministro redundante) CA V 50/60 Hz 8-3.5A CA V 50/60 Hz 8-3.5A Denan statement (Japan/Nippon only) NN ( D Version 01.02)

7 7 Contents How to get help Introducing the Nortel WLAN 2300 system Nortel WLAN 2300 System Documentation WSS overview WSS model numbers Hardware features switch Nortel WSS 2360/2361 switch switch Management features Power features Network interfaces Status LEDs , 2361 and 2380 LEDs LEDs Software features Management features Layer 2 switching features IP services Authentication, authorization, and accounting Roaming RF management External antenna selector guides for AP-2330, AP-2330A and AP-2330B Installing and connecting a WSS Unpacking a WSS Installation requirements and recommendations WLAN Management software network plan Installation location Cable Requirements Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

8 8 Contents Serial console cable Network cables AP cable requirement Installation hardware and tools Installing a WSS Equipment rack installation Tabletop installation Installing a power supply in a 2380 switch Installing a new power supply Replacing a power supply Powering on a WSS Powering on a 2360/2361, or Powering on a Connecting to a serial management console Troubleshooting a serial management connection Connecting to the network Connecting to an AP or other 10/100 Ethernet device Connecting to gigabit ethernet devices Connecting to a copper gigabit device (2380 only) Connecting to a fiber gigabit device (2380) WSS technical specifications WSS troubleshooting Index NN ( D Version 01.02)

9 9 How to get help This section explains how to get help for Nortel products and services. Getting help from the Nortel web site The best way to get technical support for Nortel products is from the Nortel Technical Support Web site: This site provides quick access to software, documentation, bulletins, and tools to address issues with Nortel products. More specifically, the site enables you to: download software, documentation, and product bulletins search the Technical Support Web site and the Nortel Knowledge Base for answers to technical issues sign up for automatic notification of new software and documentation for Nortel equipment open and manage technical support cases Getting help over the phone from a Nortel solutions center If you don t find the information you require on the Nortel Technical Support Web site, and have a Nortel support contract, you can also get help over the phone from a Nortel Solutions Center. In North America, call NORTEL ( ). Outside North America, go to the following Web site to obtain the phone number for your region: Getting help from a specialist by using an express routing code To access some Nortel Technical Solutions Centers, you can use an Express Routing Code (ERC) to quickly route your call to a specialist in your Nortel product or service. To locate the ERC for your product or service, go to: Getting help through a Nortel distributor or reseller If you purchased a service contract for your Nortel product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

10 10 How to get help NN ( D Version 01.02)

11 11 Introducing the Nortel WLAN 2300 system Nortel WLAN 2300 System Documentation This guide shows you how to install a Nortel WLAN Security Switch (WSS) in a Nortel WLAN 2300 System wireless LAN (WLAN) and deploy basic IEEE wireless service. Read this guide if you are a network administrator or other person installing WSSs and deploying wireless service in a network. Nortel WLAN 2300 System The Nortel WLAN 2300 System is an enterprise-class WLAN solution that seamlessly integrates with an existing wired enterprise network. The Nortel system provides secure connectivity to both wireless and wired users in large environments such as office buildings, hospitals, and university campuses and in small environments such as branch offices. The Nortel WLAN 2300 System fulfills the three fundamental requirements of an enterprise WLAN: It eliminates the distinction between wired and wireless networks, allows users to work safely from anywhere (secure mobility), and provides a comprehensive suite of intuitive tools for planning and managing the network before and after deployment, greatly easing the operational burden on IT resources. The Nortel WLAN 2300 System consists of the following components: WLAN Management Software tool suite A full-featured graphical user interface (GUI) application used to plan, configure, deploy, and manage a WLAN and its users One or more WLAN Security Switch (WSS) Distributed, intelligent machines for managing user connectivity, connecting and powering Access Points (APs), and connecting the WLAN to the wired network backbone Multiple Access Points (APs) Wireless access points (APs) that transmit and receive radio frequency (RF) signals to and from wireless users and connect them to a WSS WLAN 2300 System Software (WSS Software) The operating system that runs all WSSs and APs in a WLAN, and is accessible through a command-line interface (CLI), the Web View interface, or the WLAN Management Software GUI Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

12 12 Introducing the Nortel WLAN 2300 system Documentation Consult the following documents to plan, install, configure, and manage a Nortel WLAN 2300 System. Planning, configuration, and deployment Nortel WLAN Management Software 2300 Series User s Guide. Instructions for planning, configuring, deploying, and managing the entire WLAN with the WLAN Management Software tool suite. Read this guide to learn how to plan wireless services, how to configure and deploy Nortel equipment to provide those services, and how to optimize and manage your WLAN. Nortel WLAN Management Software 2300 Series Reference Guide. Detailed instructions and information for all WLAN Management Software planning, configuration, and management features. Installation Nortel WLAN Security Switch Hardware Installation Guide (this document). Instructions and specifications for installing a WSS Nortel WLAN 2300 System Software Quick Start Guide. Instructions for performing basic setup of secure (802.1X) and guest (Web-based AAA) access, and for configuring a Mobility Domain for roaming Nortel Access Point 2330 Installation Guide. Instructions and specifications for installing the AP-2330 access point and connecting it to a WSS Configuration and management Nortel WLAN Management Software 2300 Series Reference Manual. Instructions for planning, configuring, deploying, and managing the entire WLAN with the WLAN Management Software tool suite Nortel WLAN 2300 System Software Configuration Guide. Instructions for configuring and managing the system through the WSS Software CLI Nortel WLAN 2300 System Command Line Reference. Functional and alphabetic reference to all WSS Software commands supported on WSSs and APs NN ( D Version 01.02)

13 Introducing the Nortel WLAN 2300 system 13 Safety and advisory notices The following kinds of safety and advisory notices appear in this manual. For translations of the warning conventions and of all warnings in this manual, consult the Translations of Important Messages section of this installation guide. Caution! This situation or condition can lead to data loss or damage to the product or other property. Warning! This situation or condition can cause injury. Warning! High voltage. This situation or condition can cause injury due to electric shock. Warning! Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment. Note. This information is of special interest. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

14 14 Introducing the Nortel WLAN 2300 system Text and syntax conventions Nortel manuals use the following text and syntax conventions: Convention Monospace text Bold text Italic text Use Sets off command syntax or sample commands and system responses. Highlights commands that you enter or items you select. Designates command variables that you replace with appropriate values, or highlights publication titles or words requiring special emphasis. Menu Name > Command Indicates a menu item that you select. For example, File > New indicates that you select New from the File menu. [ ] (square brackets) Enclose optional parameters in command syntax. { } (curly brackets) Enclose mandatory parameters in command syntax. (vertical bar) Separates mutually exclusive options in command syntax. NN ( D Version 01.02)

15 WSS overview 15 WSS overview WSS model numbers Hardware features Software features External antenna selector guides for AP-2330, AP-2330A and AP-2330B A Nortel WLAN Security Switch (WSS) provides mobility and authentication, authorization, and accounting (AAA) services for wireless or wired users. A WSS also controls the operation of Nortel Access Points, which control and manage IEEE operation over the air. Warning! Installation must be performed by qualified service personnel only. Read and follow all warning notices and instructions marked on the product or included in the documentation. Before installing the product, read the Nortel Regulatory Information section of this document. Warning! There are no user-serviceable parts inside the WSSs. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

16 16 WSS overview WSS model numbers Table 1 lists the WSS model numbers. Hardware features 2350 switch Table 1: WSS Model Numbers Model Port Configuration Power Supply Configuration 2350 Two 10/100BASE-TX Ethernet ports Port 1 provides an uplink to the network. Port 2 supports Power over Ethernet (PoE) and provides direct connection to an AP Eight 10/100 Ethernet ports, six of which support PoE 2361 Eight 10/100 Ethernet ports, six of which support PoE 2380 Four dual-interface gigabit Ethernet ports. Each port has a 1000BASE-TX copper interface and a Gigabit interface converter (GBIC) slot for insertion of a 1000BASE-SX or 1000BASE-LX fiber-optic interface. One VAC autosensing AC power supply One VAC / VAC autosensing AC power supply Two VAC / VAC autosensing AC power supplies Two VAC / VAC autosensing AC power supplies A 2350 switch is compact and can be installed on a tabletop. Figure 1 shows a front view and the external hardware features of a 2350 switch. Figure 1. Nortel 2350 Switch Front View Factory Reset switch Factory Reset LED 1 2 Serial console port 10/100 Ethernet uplink port 10/100 and AP Ethernet port Power supply input Power supply LED NN ( D Version 01.02)

17 WSS overview 17 Nortel WSS 2360/2361 switch A WSS 2360/2361 switch is one (RU) high and also can be installed in a standard cm (19-inch) equipment rack or on a tabletop. Figure 2 shows a front view of a WSS Figure 2. Nortel WSS 2360 Switch Front View 44.2 cm (17.4 inches) 25.6 cm (10.8 inches) 4.4 cm (1.72 inches) Rst AP Figure 3 shows the external hardware features of a WSS Figure 3. WSS 2360 Switch Front Panel Control Features Power supply Serial console port AP Power supply LED 10/100 Ethernet uplink ports 10/100 and AP/PoE LEDs 10/100 and AP Ethernet ports The rear of the switch contains a label with the serial ID, MAC address, and other identifying information. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

18 18 WSS overview 2380 switch A WSS 2380 is two rack units (RUs) high and can be installed in a standard cm (19-inch) equipment rack or on a tabletop. Figure 4 shows a front view of a WSS 2380 and identifies the external hardware features. Figure 4. WSS 2380 Front Panel Control Features Power supply LED Power supply Serial console port Flash card slot Eject button Mgmt LED V 50/60 Hz 8A MAX Console Mgmt DISCONNECT ALL POWER BEFORE SERVICING AC power inlet Power supply serial number GBIC slot Gigabit link LEDs 1000BASE-TX port Like the other switch models, the rear of the 2380 switch contains a label with the serial ID, MAC address, and other identifying information. NN ( D Version 01.02)

19 WSS overview 19 Management features Serial console port The serial console port provides a direct management connection to a WSS s command-line interface (CLI). The port has a DB-9 female connector and supports the EIA-232D signaling standard. Restart switch The restart switch allows you to restart a 2350 without removing the power cord(s). Caution! The reset switch on the 2350 performs two functions. If you press the reset switch for less than 5 seconds, it restarts the 2350 and reloads its configuration from the configuration file. However, if you press the switch for 5 seconds or longer, the configuration file is deleted and the switch restarts with its factory default settings. If you accidentally press the factory reset switch for too long and erase the configuration, you can use the Web Quick Start to reconfigure the switch. Status LEDs The Ethernet ports and power supplies on all switch models have LEDs that indicate their status. The management CPU on a 2380 also has an LED. (For details, see Status LEDs on page 20.) Flash card slot (2380 only) The flash card slot is not used for normal WSS operation. Power features Power supplies A 2380 switch comes with one VAC autosensing AC power supply. You can add a second supply for load sharing and redundancy. The power supplies are hot-swappable. A 2360/2361 switch contains either one or two VAC / VAC autosensing AC power supplies. The 2360/2361 power supplies are fixed-configuration supplies and cannot be inserted or removed. A 2350 switch uses an external power supply, which comes with the switch. Network interfaces 10/100 Ethernet ports A 2350 switch has two 10/100BASE-TX Ethernet ports. A 2360 switch has eight 10/100BASE-TX Ethernet ports. Each port has a standard RJ-45 connector and uses Category 5 (Cat-5) cable based on the EIA/TIA-586 standard. On the 2350, port 2 can be configured for APs and can support Power over Ethernet (PoE). Port 1 is an uplink port only and does not support PoE. On the 2360/2361 switch, ports 1 through 6 can be configured for APs and can support PoE. Ports 7 and 8 on the 2360/2361 switch are uplink ports only and do not support PoE. The 10/100 Ethernet ports on the 2360/2361 and 2350 switches provide automatic MDI/MDX, which automatically crosses over the send and receive signals if required. The 2380 provides high-bandwidth centralized control of many indirectly connected APs. The 2380 does not have 10/100 Ethernet ports and does not provide PoE. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

20 20 WSS overview Status LEDs Gigabit interface converter (GBIC) slots (2380 only) A 2380 switch has four ports. Each port has a slot for a 1000BASE-SX or 1000BASE-LX fiber-optic GBIC, and a built-in 1000BASE-TX copper interface with an RJ-45 connector. Only one interface, copper or fiber, can be enabled on a port. The GBIC interface is enabled by default. You can enable the copper interface (and disable the fiber interface) if needed. The gigabit Ethernet ports operate at 1000 Mbps only. They do not change speed to match 10-Mbps or 100-Mbps links. The fiber-optic GBICs have standard SC Duplex connectors and use either single-mode fiber (SMF) for LX or multimode fiber (MMF) for SX. GBICs are available separately and are not included with the switch. The WSSs have LEDs that indicate port, power, and CPU status. 2360, 2361 and 2380 LEDs Table 2 lists the LEDs for models 2360, 2361, and Table 2: WSS Status LEDs 2360, 2361 and 2380 LED Appearance Meaning Mgmt (2380 only) Bright green, then fade (repeated) Note: This LED appearance is sometimes called breathing. WSS is operating normally. Blinking green WSS is booting. Quickly blinking amber WSS was unable to boot completely. Power supply status Solid green DC power output is on. Solid amber Power fault has occurred. Unlit AC power is off. Gigabit fiber link Solid green 1000-Mbps fiber link is operational. activity (2380 only) Blinking green (2380) Traffic is active on the 1000-Mbps fiber link. Gigabit copper link activity (2380 only) Link (2360 and 2361 only) Solid green Blinking green Solid green Solid amber Blinking green Blinking amber 1000-Mbps copper link is operational. Traffic is active on the 1000-Mbps copper link. 100-Mbps link is operational. 10-Mbps link is operational. Traffic is active on the 100-Mbps link. Traffic is active on the 10-Mbps link. NN ( D Version 01.02)

21 WSS overview 21 Table 2: WSS Status LEDs 2360, 2361 and 2380 (continued) LED Appearance Meaning AP (2360 and 2361 only) Solid green Alternating green and amber Solid amber Blinking amber Unlit For an AP s active link, with PoE enabled, all the following are true: AP has booted. AP has received a valid configuration from the WSS. Management link with an AP is operational. AP is booting with an image received from the WSS. If the LED remains in this state indefinitely, the boot or configuration attempt has failed. PoE is on but no AP is connected to the link. AP is not connected or is unresponsive, or there is a PoE problem. Port is not configured as an AP access port, or PoE is off LEDs Figure 5 on page 21 shows the locations of the 2350 LEDs. Table 3 describes the LEDs. Figure LEDs Factory Reset LED AP LED 1 2 Link LED Power supply LED Table 3: WSS Status LEDs 2350 LED Appearance Meaning Power status Solid green The switch is receiving power. Unlit The switch is not receiving power. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

22 22 WSS overview Link (ports 1 and 2) Factory Reset (port 1 only) Table 3: WSS Status LEDs 2350 (continued) LED Appearance Meaning Solid green Solid amber Blinking green Blinking amber Solid green Blinking green Unlit 100-Mbps link is operational. 10-Mbps link is operational. Traffic is active on the 100-Mbps link. Traffic is active on the 10-Mbps link. The switch is booting and is loading its configuration file. This LED state lasts for three seconds. The switch is booting but the factory reset switch is being pressed. The switch does not load its configuration file but instead contacts WLAN Management Software to request a configuration. This LED state lasts for three seconds. The switch has finished booting. AP (port 2 only) Solid green For an AP s active link, with PoE enabled, all the following are true: AP has booted. AP has received a valid configuration from the WSS. Management link with an AP is operational. Alternating green and amber Solid amber Blinking amber Unlit AP is booting with an image received from the WSS. If the LED remains in this state indefinitely, the boot or configuration attempt has failed. PoE is on but no AP is connected to the link. AP is not connected or is unresponsive, or there is a PoE problem. Port is not configured as an AP access port, or PoE is off. NN ( D Version 01.02)

23 WSS overview 23 Software features WLAN 2300 System Software (WSS Software) provides a combination of standard wired LAN features and wireless LAN features that enable you to integrate the switch into your wired network and provide network access for wired or wireless users. Management features Serial and network command-line interface (CLI) access You can access the CLI through a direct serial connection or through the network using Secure Shell (SSH) or Telnet. WLAN Management Software management application WLAN Management Software is an extensive GUI application for planning, configuring, deploying, and managing a Nortel network and its users. WLAN Management Software uses Secure Sockets Layer protocol (SSL) to interact with WSS Software. Software and configuration management You can store multiple software images and configuration files in the WSS s nonvolatile storage. Web View manager Web View is a Web-based application for configuring and managing a single WSS through a Web browser. Web View creates a secure connection by using Hypertext Transfer Protocol over Secure Sockets Layer (HTTPS). Layer 2 switching features Spanning Tree Protocol (STP) WSS Software supports Per-VLAN Spanning Tree (PVST+). PVST+ allows a separate spanning tree in each virtual LAN (VLAN). Optional fast convergence features allow you to quickly resume traffic forwarding after a topology change. Load-sharing port groups You can configure multiple physical ports into a single logical link for traffic load sharing and physical link redundancy. Virtual LANs (VLANs) WSS Software supports logical segmentation of a switch s ports into separate Layer 2 broadcast domains. A port can be a member of one or more VLANs. Each VLAN can have its own IP interface. WSS Software supports the 802.1Q tag format. Internet Group Management Protocol (IGMP) snooping for multicast containment The WSS can learn about the multicast sources and receivers in the network and restrict forwarding for a multicast group to the users for that group. IGMPv1 and IGMPv2 are supported. IP services IP interfaces You can configure an IP interface for each VLAN. IP ping and traceroute You can test IP connectivity between the WSS and other devices. Domain Name Service (DNS) You can configure the switch to use DNS servers for name resolution. You also can configure a default domain name to append to hostnames. Network Time Protocol (NTP) A WSS can sets its time and date by polling an NTP server. System log A WSS generates log messages to log system events. The log messages are stored locally and also can be exported to syslog servers. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

24 24 WSS overview Simple Network Management Protocol (SNMP) A WSS can be configured to generate SNMP traps for major system events. Authentication, authorization, and accounting 802.1X A WSS can authenticate users based on 802.1X protocols. Based on authentication, users are assigned VLAN membership, access control, and roaming boundaries. MAC authentication If a device does not support 802.1X, you can configure authentication based on the source MAC address to assign VLAN membership, access control, and roaming boundaries. Guest authentication Guests can be authenticated by a shared set of authorization attributes that assign VLAN membership, access control, and roaming boundaries. Local and remote authentication You can authenticate users locally using information configured on the WSS, or use a Remote Authentication Dial-In User Service (RADIUS) server. When you use a remote server, the WSS can enhance performance by performing some of the AAA tasks locally or distributing the load across multiple servers. Roaming AP roaming You can configure the WSS to allow users to roam from one AP to another on the same WSS. Mobility Domain roaming You also can configure a group of WSSs to allow users to roam from one switch to another. Regardless of the wired subnet connections, each user maintains the same IP address and session across the network. Session management You can display session information and statistics for users. RF management RF Auto-Tuning WSS Software can automatically assign channels and power settings to APs based on RF information collected from the network. Radio frequency (RF) topology With WLAN Management Software, you can verify site coverage and capacity. Rogue detection and countermeasures APs can be used to gather RF information for validating an RF deployment plan, and for detecting and combatting rogue access points. User-based RF You can gather statistics on a per-user basis as users roam across the network. NN ( D Version 01.02)

25 WSS overview 25 External antenna selector guides for AP-2330, AP-2330A and AP-2330B Table 4: External Antenna Selector Guide for the AP-2330/AP-2330A/AP-2330B for indoor operation Cushcraft Nortel Model Number WSS Model String WLAN AP-2330/AP-2330A/AP-2330B 2.4 GHz Antennas S2403BHN36RSM S2403BPXN36RSM DR E6 (Discontinued) DR E6 (Replaces DR E6) DR E6 has been replaced with the DR E6. They have the same electrical characteristics and the DR E6 can now be mounted on either a pole or hung from a ceiling WLAN Collinear Omni-directional Dipole Antenna contains two collocated elements with an average gain of 4.9 dbi and a 3-foot cable with a Reverse SMA connector. For use in Warehouses, Auditoriums, Shopping Malls, industrial complexes and more. It can be mounted either on a pole or hung from a ceiling. S2406PN36RSM DR E WLAN Directional Patch Panel Antenna with an average gain of 6.5 dbi and a 3-foot cable with a Reverse SMA connector. For use in Hallways or corridors. Easy to disguise or hide. SL2402PN36RSM DR E WLAN Omni-directional Patch Panel Ceiling Mount Antenna with an average gain of 0.0 dbi and a 3-foot cable with a Reverse SMA connector. For use in contemporary in-building WLAN applications. SQ2405DDN36RSM DR E WLAN Bi-directional Patch Panel Ceiling Mount Antenna with an average gain of 4.5 dbi and a 3-foot cable with a Reverse SMA connector. For use in Offices, Shopping Complexes, Transportation Terminals, Educational Campuses, Hallways, and Tunnels. S2409PN36RSM DR E WLAN Directional Patch Panel Array Antenna with an average gain of 8.8 dbi and a 3-foot cable with a Reverse SMA connector. For use where a shaped pattern is needed to provide enhanced coverage of deep rooms, warehouse bays, or any elongated activity zone PC2415NA36RSM DR E WLAN 15-Element Yagi Antenna with an average gain of 14.1 dbi, 3-foot cable with a Reverse SMA connector and an articulating mount. Antenna is rugged, easy to install and provides a very symmetrical and uniform pattern. Designed for long, narrow coverage environments, like a tunnel. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

26 26 WSS overview Table 4: External Antenna Selector Guide for the AP-2330/AP-2330A/AP-2330B for indoor operation SR24120DN36RSM DR E WLAN Directional Patch Panel Array Antenna with an average gain of 11 dbi, 3-foot cable with a Reverse SMA connector and either a tilt, wall or pole mounting capability. Antenna is rugged, easy to install and provides a very symmetrical and uniform 120 degree H-plane and 14 degree E-plane pattern. Designed for long, wide coverage environments. Certified for use with the AP-2330A and AP-2330B ONLY. S241290PN36RSM DR E WLAN Directional Patch Panel Array Antenna with an average gain of 12 dbi, 3-foot cable with a Reverse SMA connector and either a tilt, wall or pole mounting capability. Antenna is rugged, easy to install and provides a very symmetrical and uniform 90 degree H-plane and 17 degree E-plane pattern. Designed for long, wide coverage environments. Certified for use with the AP-2330A and AP-2330B ONLY. Cushcraft Nortel Model Number WSS Model String WLAN AP-2330/AP-2330A/AP-2330B 5.0 GHz Antennas SQ5153WPN36RSM DR E WLAN Squint Ceiling Mount Omni-directional Monopole Antenna with an average gain of 3.2 dbi from GHz, 2.5 dbi from GHz, 1.6 dbi from GHz and 0.1 dbi from GHz. It has a 3-foot cable with a Reverse SMA connector. For use in large indoor spaces, locations with high ceilings, and where extending coverage is needed. S5153WBPN36RSM DR E WLAN Collinear Omni-directional Dipole Antenna that contains two collocated elements. It has an average gain of 4.5 dbi from GHz, 3.8 dbi from GHz, 4.7 dbi from GHz and 4.4 dbi from GHz. It is 7" in height, and has a 3-foot cable with a Reverse SMA connector. For use in Warehouses, Auditoriums, Shopping Malls, industrial complexes and other locations. S51514WPN36RSM DR E WLAN Directional Patch Panel Antenna with an average gain of 13.1 dbi from GHz, 13.0 dbi from GHz, 13.0 dbi from GHz and 12.9 dbi from GHz. It has a 3-foot cable with a Reverse SMA connector. For use in campus or in-building applications. It offers a very precise and controllable pattern. Must order mounting bracket separately. NN ( D Version 01.02)

27 Table 4: External Antenna Selector Guide for the AP-2330/AP-2330A/AP-2330B for indoor operation Cushcraft Nortel Model Number WSS Model String WSS overview 27 WLAN AP-2330/AP-2330A/AP-2330B 2.4/5.0 GHz Dual Antennas S24493DSN36RSM DR E6 Mixed WLAN Dual-Band, Tri-Mode a/b/g Spatial Diversity Monopole Antenna. It operates over the GHz and GHz bands. It has an average gain of 3.0 dbi from GHz, 4.0 dbi from GHz, 3.9 dbi from GHz, 3.2 dbi from GHz, 2.9 dbi from GHz and 2.6 dbi from GHz. It is equipped with a 3-foot cable and a Reverse SMA connector. Each antenna port can be used individually to support b/g and a systems simultaneously for dual-band, non-diversity applications. Optimal for use in high data rate, high capacity configurations such as enterprise offices. Table 5. External Antenna Selector Guide for the AP-2330A/AP-2330B for Outdoor Operation Cushcraft Nortel Model Number WSS Model String WLAN AP-2330A and AP-2330B 2.4 GHz Antennas S2403BPXN36RSM DR E6 WLAN Collinear Omni-directional Dipole Antenna that contains two collocated elements with an average gain of 4.9 dbi and a 3-foot cable with a Reverse SMA connector. For use in Warehouses, Auditoriums, Shopping Malls, industrial complexes and more. It can be mounted either on a pole or hung from a ceiling NEMA To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable and the lightning protection circuitry NEMA-10 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

28 28 WSS overview NEMA-25 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable OUT Output power is compensated for the addition of lightning protection circuitry and the 10-foot plenum rated cable OUT-10 The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable OUT-25 The "25" refers to the addition of the 25-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable. S2409PN36RSM DR E6 WLAN Directional Patch Panel Array Antenna with an average gain of 8.8 dbi and a 3-foot cable with a Reverse SMA connector. For use where a shaped pattern is needed to provide enhanced coverage of deep rooms, warehouse bays, or any elongated activity zone NEMA To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable and the lightning protection circuitry NEMA-10 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable. NN ( D Version 01.02)

29 WSS overview NEMA-25 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable OUT Output power is compensated for the addition of lightning protection circuitry and the 10-foot plenum rated cable OUT-10 The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable OUT-25 The "25" refers to the addition of the 25-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable. PC2415NA36RSM DR E6 WLAN 15-Element Yagi Antenna with an average gain of 14.1 dbi, 3-foot cable with a Reverse SMA connector and an articulating mount. Antenna is rugged, easy to install and provides a very symmetrical and uniform pattern. Designed for long, narrow coverage environments, like a tunnel NEMA To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable and the lightning protection circuitry NEMA-10 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

30 30 WSS overview NEMA-25 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable OUT Output power is compensated for the addition of lightning protection circuitry and the 10-foot plenum rated cable OUT-10 The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable OUT-25 The "25" refers to the addition of the 25-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable. S241290PN36RSM DR E6 WLAN Directional Patch Panel Array Antenna with an average gain of 12 dbi, 3-foot cable with a Reverse SMA connector and either a tilt, wall or pole mounting capability. Antenna is rugged, easy to install and provides a very symmetrical and uniform 90 degree H-plane and 17 degree E-plane pattern. Designed for long, wide coverage environments NEMA To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable and the lightning protection circuitry NEMA-10 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable. NN ( D Version 01.02)

31 WSS overview NEMA-25 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable OUT Output power is compensated for the addition of lightning protection circuitry and the 10-foot plenum rated cable OUT-10 The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable OUT-25 The "25" refers to the addition of the 25-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable. SR24120DN36RSM DR E6 WLAN Directional Patch Panel Array Antenna with an average gain of 11 dbi, 3-foot cable with a Reverse SMA connector and either a tilt, wall or pole mounting capability. Antenna is rugged, easy to install and provides a very symmetrical and uniform 120 degree H-plane and 14 degree E-plane pattern. Designed for long, wide coverage environments NEMA To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable and the lightning protection circuitry NEMA-10 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

32 32 WSS overview NEMA-25 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable OUT Output power is compensated for the addition of lightning protection circuitry and the 10-foot plenum rated cable OUT-10 The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable OUT-25 The "25" refers to the addition of the 25-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable. Cushcraft Nortel Model Number WSS Model String WLAN AP-2330A and AP-2330B 5.0 GHz Antennas S5153WBPN36RSM DR E6 WLAN Collinear Omni-directional Dipole Antenna that contains two collocated elements. It has an average gain of 4.5 dbi from GHz, 3.8 dbi from GHz, 4.7 dbi from GHz and 4.4 dbi from GHz. It is 7" in height, and has a 3-foot cable with a Reverse SMA connector. For use in Warehouses, Auditoriums, Shopping Malls, industrial complexes and other locations NEMA To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable and the lightning protection circuitry. NN ( D Version 01.02)

33 WSS overview NEMA-10 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable NEMA-25 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable OUT Output power is compensated for the addition of lightning protection circuitry and the 10-foot plenum rated cable OUT-10 The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable OUT-25 The "25" refers to the addition of the 25-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable. S51514WPN36RSM DR E NEMA WLAN Directional Patch Panel Antenna with an average gain of 13.1 dbi from GHz, 13.0 dbi from GHz, 13.0 dbi from GHz and 12.9 dbi from GHz. It has a 3-foot cable with a Reverse SMA connector. For use in campus or in-building applications. It offers a very precise and controllable pattern. Must order mounting bracket separately. To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable and the lightning protection circuitry. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

34 34 WSS overview NEMA-10 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable NEMA-25 To be used with the outdoor NEMA enclosure only. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable OUT Output power is compensated for the addition of lightning protection circuitry and the 10-foot plenum rated cable OUT-10 The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 10-foot outdoor rated extension cable OUT-25 The "25" refers to the addition of the 25-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the addition of the 10-foot plenum rated cable, the lightning protection circuitry and the 25-foot outdoor rated extension cable. NN ( D Version 01.02)

35 35 Installing and connecting a WSS Unpacking a WSS Installation requirements and recommendations Installing a WSS Installing a power supply in a 2380 switch Powering on a WSS Connecting to a serial management console Troubleshooting a serial management connection Connecting to the network Note. Before installing a WSS, you might need to generate a network plan with WLAN Management Software. (See WLAN Management software network plan on page 37.) Unpacking a WSS The shipping carton for a WSS contains the following items: One 2360, with one power supply (or two power supplies, if you ordered the 2361) For some countries, one country-specific power cord One serial cable for connection to the management console (not included with the 2350) Two rack-mount brackets (not applicable to the 2350) Four adhesive rubber feet One documentation pack that includes this guide One set of release notes Figure 6 shows the contents of the shipping carton for a 2360 switch. The contents of a 2361 or 2380 shipping carton are similar. The 2350 carton contains the switch, a power supply and cord, rubber feet, a documentation pack, and release notes. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

36 36 Installing and connecting a WSS Figure 6. Typical Switch Shipping Carton Contents Port WSS with installed power supply Documentation pack Power cord Serial cable Before you begin installation: Rack-mount brackets Rubber feet 1 Open the carton and carefully remove the contents, if you have not already done so. 2 Place the packing materials back in the carton and save the carton. 3 Verify that you received each item in the previous list. If any item is missing or damaged, contact Nortel NN ( D Version 01.02)

37 Installing and connecting a WSS 37 Installation requirements and recommendations For best results, follow these requirements and recommendations before installing a WSS. WLAN Management software network plan If you are using WLAN Management Software to plan your Nortel WLAN 2300 System installation, Nortel recommends that you create and verify a network plan for the entire Nortel network installation before installing WSSs or APs. A network plan provides the following information: Number of WSSs required at your site, and where to install them Number of APs required for adequate WLAN capacity in each coverage area, and where to install them Configuration settings for all the WSSs and APs in the WLAN, which can be automatically deployed to the devices by WLAN Management Software. (For information about installing WLAN Management Software and creating and verifying a network plan, see the Nortel WLAN Management Software User s Guide.) Installation location Caution! For installations in Japan: Provide an earthing connection before you connect the mains plug to the mains. When disconnecting the earthing connection, make sure to disconnect only after you pull out the mains plug for the mains. Caution! Do not stack 2350 switches. Stacked 2350 switches can overheat and cause loss of equipment functionality or permanent damage. Caution! Ensure adequate airflow around 2350 switches. The 2350 switch uses natural convection cooling and requires free entry of air. Airflow blockage can cause the system to overheat and result in a loss of equipment functionality or permanent damage switch fans and air inlets are located on the sides of the switch. 2360/2361 switch fans are located in the rear of the switch and air inlets are located on the sides of the switch. In the 2380 switches, separate power supply fans are located on the front. Make sure these areas have adequate ventilation after installation. Do not block air vents. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

38 38 Installing and connecting a WSS Cable Requirements Warning! The gigabit Ethernet fiber-optic interfaces use Class 1 lasers. To reduce the risk of eye injury, do not stare into the interface or otherwise direct the laser beam into your eye. To avoid installation problems, use the proper cables. Serial console cable 8769EB The serial console port has a female DB-9 connector and supports the EIA-232D signaling standard. You need a standard DB-9-male-to-DB-9-female PC modem cable. Table 6 lists the pin signals. Table 6: Serial Console Pin Signals WSS Pin Usage PC Pin Usage 2 Receive 3 Transmit 3 Transmit 2 Receive 5 Ground 5 Ground NN ( D Version 01.02)

39 Installing and connecting a WSS 39 Network cables Table 7 lists the interface types supported by WSS and the cable type required for each type of interface. Link Type Cable Type 10/100 Ethernet cable wiring Table 7: Ethernet Interfaces Connector Type Maximum Distance 10/100BASE-T Cat-5 copper RJ m (328 feet) Straight-through or crossover signaling 1000BASE-SX Multimode 50-µm fiber SC 550 m ( feet) Multimode 62.5-µm fiber SC 275 m (902.2 feet) 1000BASE-LX Single mode 9/10-µm fiber SC 10,000 m (32,808.4 feet) Multimode 50-µm fiber SC 550 m ( feet) Multimode 62.5-µm fiber SC 550 m ( feet) 1000BASE-TX Cat-5 copper Can use straight-through or crossover signaling, provided all four wire pairs are connected RJ m (328 feet) Connections on the 10/100 ports require Category 5 (Cat-5) cable based on the EIA/TIA-586 standard. For direct connection to an AP, a router, or an end station such as a PC, printer, or server, use a straight-through cable. For direct connection to another switch, use a crossover cable. (The 10/100 Ethernet ports on the 2360 switch provides automatic MDI/MDX, which automatically crosses over the send and receive signals if required.) Table 8 on page 39 lists the pin signals for 10/100 Ethernet straight-through wiring. Pins 4, 5, 7, and 8 are used only when Power over Ethernet (PoE) is enabled on the port. RD means Receive Data and TD means Transmit Data. Table 8: 10/100 Ethernet Straight-Through Pin Signals WSS Other Device Pin Function Pin Function 1 RD+ 1 TD+ 2 RD- 2 TD- 3 TD+ 3 RD+ 4 PoE+ 4 PoE+ 5 PoE+ 5 PoE+ Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

40 40 Installing and connecting a WSS Table 8: 10/100 Ethernet Straight-Through Pin Signals (continued) WSS Other Device Pin Function Pin Function 6 TD- 6 RD- 7 PoE- 7 PoE- 8 PoE- 8 PoE- AP cable requirement Use a straight-through Ethernet cable to connect an AP directly to a WSS or indirectly through another device. 1000BASETX Gigabit Ethernet cable wiring Use Cat-5 Enhanced (Cat-5E) or better cable. 1000BASE-TX uses all 8 wires in the cable. The wiring can be straight-through or crossover. The port automatically configures its pin signals accordingly. Note. PoE is not supported on 1000BASE-TX links. All wires in the cable are used for data. Installation hardware and tools Caution! To reduce the risk of equipment damage, make sure the WSS is installed so that the mechanical load on the device is evenly distributed. For example, make sure the switch is level in the equipment rack, is evenly fastened by screws on either side, and does not have a heavy object resting on one side of the switch. NN ( D Version 01.02)

41 Installing and connecting a WSS 41 Table 9 lists the mounting hardware and tools required for each type of installation. Table 9: Required Mounting Hardware and Tools Mounting Option Required Hardware and Tools Included with the Product Equipment rack Front-mount or center-mount option for the 2380 Front-mount option for the 2360/2361 Tabletop (applicable to all switch models) Mounting brackets Four rack-mount screws and screwdriver Note: Equipment racks vary, and the screw and screwdriver type depend on the equipment rack. Power cords Serial console cable Four adhesive rubber feet Power cord(s) Serial console cable Yes No Yes (one) Yes Yes Yes Yes Installing a WSS You can mount a 2360/2361, or 2380 switch in a standard cm (19-inch) equipment rack or on a tabletop. Each WSS is shipped with two brackets for rack mounting and four adhesive rubber feet for tabletop mounting. The 2380 mounting brackets support either front or center mounting. The 2360/2361 mounting brackets support front mounting only. The 2350 switch does not have rack mounting brackets but can be installed on a tabletop. To install a WSS, use one of the following procedures. Warning! Earth grounding is required for a WSS installed in a rack. If you are relying on the rack to provide ground, the rack itself must be grounded with a ground strap to the earth ground. Metal screws attaching the switch to the rack provide ground attachment to the rack. Warning! In the U.S., overcurrent protection must be provided by the installation. Branch circuit protection in accordance with National Fire Protection Association (NFPA) 70, National Electrical Code (NEC) is required. Consideration must be given to the electrical ratings on the WSS and branch circuit protection. Do not install equipment such that the branch circuit current and voltage protection is exceeded. Pay particular attention to the earthing connection for the supply connections. When using an extension cord or power strip, pay attention to the grounding type. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

42 42 Installing and connecting a WSS Equipment rack installation You can install a 2380 switch into a front-mount or center-mount equipment rack. You can install a 2360/2361 switch into a front-mount equipment rack. Figure 7 shows how to install a 2380 switch into a front-mount equipment rack. (Installation of a 2360/2361 is similar.) Figure 8 shows how to install a 2380 switch into a center-mount equipment rack. Refer to these figures as you perform the procedure. Figure Installation Front-Mount Equipment Rack First, attach brackets to chassis. Then, install chassis into rack NN ( D Version 01.02)

43 Installing and connecting a WSS 43 Figure Installation Center-Mount Equipment Rack First, attach brackets to chassis. Rst Console Rst Console Then, install chassis into rack Remove the four bracket screws from each side of the Align a bracket over the screw holes: For a front-mount equipment rack, align the bracket so that the bracket flange is flush with the 2380 s front panel and extends away from the switch. For a center-mount equipment rack, align the bracket so that the bracket flange is located near the center screw holes. 3 Reinsert the screws to secure the brackets to the Repeat for the other bracket. Warning! Nortel recommends that you ask someone to assist you with the remaining steps. If you accidentally drop the WSS, you can be injured and the switch can be damaged. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

44 44 Installing and connecting a WSS 5 Lift the 2380 into position in the equipment rack. Warning! To prevent the WSS from slipping, do not release the switch until all the rack-mount screws are tight. 6 Insert the bottom rack-mount screws into the bracket flanges to secure the 2380 to the equipment rack, then insert the top screws. 7 Do one of the following: If you are installing a second power supply into a 2380 switch, go to Installing a power supply in a 2380 switch on page 44. If you are ready to turn on power, go to Powering on a WSS on page 47. Tabletop installation 1 On a clean work surface with no debris, carefully turn the WSS upside down. 2 Wipe the four placement locations for the rubber feet to clear away any oil or dust. The location areas are marked by X s. 3 Attach the four rubber adhesive feet over the X s. 4 Turn the WSS right-side up, and place the switch in position on the table. 5 Do one of the following: If you are installing a second power supply into a 2380 switch, go to Installing a power supply in a 2380 switch. If you are ready to turn on power, go to Powering on a WSS on page 47. Installing a power supply in a 2380 switch A 2380 switch is shipped with a single VAC autosensing AC power supply. One power supply provides enough power for a fully configured system. You can add a second power supply for load sharing and redundancy. A WSS containing one power supply can have the supply installed in either slot. If the switch contains two power supplies and one supply fails, the other supply automatically takes over to provide uninterrupted operation. The power supplies are hot-swappable. You can remove or insert a power supply while the other power supply is running. Use the following procedures to install a second power supply or replace a failed power supply. (You cannot insert or remove power supplies in a 2360 switch.) Note. To attach the power supply to a 2350, see Powering on a 2350 on page 48. NN ( D Version 01.02)

45 Installing and connecting a WSS 45 Installing a new power supply 1 If you are replacing a failed power supply and have not already removed it from the WSS, go to Replacing a power supply on page If you are installing a new power supply in an unused slot, loosen the thumbscrew with a #2 Phillips-head screwdriver and remove the cover plate. Store the cover plate in a safe place in case you need to use it at another time. 3 Remove the new power supply from its packaging and lift the supply by grasping the front handle with one hand and supporting the supply from the bottom with the other hand. 4 Insert the power supply into the 2380 s slot as shown in Figure 9, pushing gently but firmly until the supply is fully seated and flush with the switch s front panel. Figure 9. Inserting a Power Supply in a Tighten the thumbscrew using a #2 Phillips-head screwdriver. 6 Go to Powering on a WSS on page 47. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

46 46 Installing and connecting a WSS Replacing a power supply 1 Remove the power cord from the power supply. 2 Loosen the thumbscrew using a #2 Phillips-head screwdriver as shown in Figure Use the handle to pull the power supply partway out of the slot as shown in Figure 10. Caution! Support the bottom of the power supply while removing it from the WSS. If the rear of the power supply is not supported, the supply will fall when you remove it, possibly damaging the rear components of the supply. Figure 10. Removing a Power Supply from a 2380 Switch Loosen thumbscrew Place your other hand under the supply to support it and remove the supply the rest of the way out of the slot. 5 Go to step 3 of Installing a new power supply on page 45. NN ( D Version 01.02)

47 Installing and connecting a WSS 47 Powering on a WSS Warning! The WSS relies on the building s installation for overcurrent protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15 A U.S. (240 VAC, 10 A international) is used on the phase conductors. Caution! If a 2350 or 2360/2361 is connected to Power Sourcing Equipment (PSE), it is possible for the switch to remain powered on even when the power cord is unplugged. PSE can be a dedicated PoE injector or even another networking switch such as the WSS that is capable of supplying PoE. To completely power off a 2350 or 2360/2361, unplug the power cord, then unplug all Ethernet cables that are connected to other PoE devices. Powering on a 2360/2361, or 2380 To power on a 2360/2361, 2380 switch: 1 Make sure any insertable power supply is fully seated in the WSS. 2 For each power supply that you are using on the WSS, attach a power cord to an AC power source. Note. If the WSS has two power supplies, use a separate AC power source for each supply to add redundancy. If one power source fails, the switch can continue to operate using the other power source. 3 Plug each power cord into a WSS power supply. The WSS begins booting as soon as you plug in the power cord(s). 4 Observe the power supply LED for each connected power supply to verify that the LED is steadily glowing green. This indicates normal power supply operation. 5 On the 2380 switch only, wait a few seconds, then observe the Mgmt LED to verify that it is breathing (repeatedly flashing bright green, then fading) to indicate that the WSS has successfully booted and is operating normally. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

48 48 Installing and connecting a WSS Powering on a 2350 To power on a 2350 switch: 1 Plug the power supply into an AC power source. 2 Plug the power supply into the Power port. The LED turns green when the 2350 is receiving power. Connecting to a serial management console Initial configuration of the WSS requires a connection to the switch s CLI through the serial console port. Figure 11 shows how to install a serial cable on a switch. The procedure is the same for the 2350, 2360, 2361, or 2380 switch. Refer to this figure as you perform the procedure. (For cable requirements, see Serial console cable on page 38.) Figure 11. Serial Cable Installation Serial port Serial cable Serial port on computer To connect a PC to the serial console port: 1 Insert the serial cable into the PC port as shown in Figure Insert the other end of the cable into the serial console port on the WSS as shown in Figure Start a standard VT100 terminal emulation application on the PC, and configure the following modem settings: 9600 bps 8 bits 1 stop No parity Hardware flow control off or disabled NN ( D Version 01.02)

49 Installing and connecting a WSS 49 4 Open a connection on a serial port. If the WSS is already powered on, press Enter three times to display a command prompt: 2380> Note. For simplicity, the command prompt examples in the documentation show the CLI access level (> for restricted access or # for enabled access) only. The default command prompt on your WSS shows your switch s model number and also contains the last three octets of the switch s MAC address. For example, the default command prompt on a 2360 switch with MAC address 00:0B:0E:00:04:0A is WSS A>. If a command prompt does not appear, go to Troubleshooting a serial management connection. To quickly perform basic setup of the WSS, see the Nortel WLAN 2300 System Software Quick Start Guide For syntax descriptions, additional configuration, and a glossary of terms, see the Nortel WLAN 2300 System Software Command Reference and the Nortel WLAN 2300 System Software Configuration Guide Troubleshooting a serial management connection 1 Verify that the WSS is powered on. 2 Verify that the serial cable is fully inserted in the PC and WSS ports. 3 Verify that the correct modem settings are configured in the terminal emulation application: 9600 bps 8 bits 1 stop No parity Hardware flow control off or disabled 4 Verify that you opened the connection on the PC port connected to the WSS. For example, if you inserted the cable in PC port COM1, make sure you open the connection on COM1 instead of COM2 or another port. If none of the previous steps results in a management connection, use another serial cable. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

50 50 Installing and connecting a WSS Connecting to the network Use the following procedures to connect a WSS to APs or other 10/100 Ethernet devices and to gigabit Ethernet devices. Connecting to an AP or other 10/100 Ethernet device Note. The 10/100 Ethernet ports are configured as wired network ports by default. You must change the port type for locally connected APs, and for wired end stations that use AAA through the WSS to access the network. Figure 12 shows how to install a Cat-5 cable for a 10/100 Ethernet port. Refer to this figure as you perform the procedure. Figure /100 Cat-5 Cable Installation Ethernet port Ethernet cable (Cat 5 cable) AP, switch, server or other device To connect to an AP or other 10/100 Ethernet device: 1 Insert a Cat-5 cable with a standard RJ-45 connector as shown in Figure 12: For direct connection to an AP, use a straight-through cable. For connection to a router or to an end station such as a PC, printer, or server, use a straight-through cable. NN ( D Version 01.02)

51 Installing and connecting a WSS 51 For connection to another switch, use a crossover cable. (For cable requirements, see Network cables on page 39.) Note. The 10/100 Ethernet ports on the 2360/2361 switches provide automatic MDI/MDX. 2 If the cable is directly attached to an AP: For a first-time installation, set the port type to activate the link. (For information, see Setting the Port Type in the Nortel WLAN 2300 System Software Configuration Guide If the port type is already set for an AP, observe the appearance of the AP LED for the port: AP LED Appearance Solid green Alternating green and amber Solid amber Blinking amber Unlit Meaning For an AP s active link, with PoE enabled, all the following are true: AP has booted. AP has received a valid configuration from the WSS. Management link with an AP is operational. For an AP s secondary link, the link is present. AP is booting with an image received from the WSS. PoE is on, but no AP is connected to the link. AP is unresponsive or there is a PoE problem. PoE is off. 3 If the cable is attached to a wired end station that uses AAA through the WSS to access the network: For a first-time installation, set the port type to activate the link. (For information, see Setting a Port for a Wired Authentication User in the Nortel WLAN 2300 System Software Configuration Guide If the port type is already set for a wired authentication port, go on to step 4. 4 If the cable is directly attached to a device other than an AP: a Observe the appearance of the Link LED for the port: Link LED Appearance Solid green Solid amber Blinking green Blinking amber Unlit Meaning 100-Mbps link is operational. 10-Mbps link is operational. Traffic is active on the 100-Mbps link. Traffic is active on the 10-Mbps link. Link is not operational. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

52 52 Installing and connecting a WSS b If the Link LED is unlit, check the cable and verify that the device at the other end of the link is operating. Connecting to gigabit ethernet devices Warning! The gigabit Ethernet fiber-optic interfaces use Class 1 lasers. To reduce the risk of eye injury, do not stare into the interface or otherwise direct the laser beam into your eye. Connecting to a copper gigabit device (2380 only) Insert a Cat-5 cable with a standard RJ-45 connector. The cable can use straight-through or crossover signalling. 1 Insert the Cat-5 cable into the port s RJ-45 (copper) interface. 2 Access the command-line interface (CLI) on the switch, use the enable command to enter configuration mode, and use the following command to set the active interface on the port to RJ-45 (copper): set port media-type port-list rj45 3 Observe the lower LED to the left of the port: If the LED is solid green, the 1000-Mbps link is operational. If the LED is blinking green, traffic is active on the 1000-Mbps link. If the LED is unlit, the link is not operational. Check the cable and verify that the device at the other end of the link is operational. Connecting to a fiber gigabit device (2380) You must install a gigabit interface converter (GBIC) to connect a 2380 to 1000BASE-SX or 1000BASE-LX cable. Figure 13 shows how to install a GBIC. Figure 14 shows how to remove one. Refer to these figures as you perform the procedures. (For cable requirements, see Network cables on page 39.) NN ( D Version 01.02)

53 Installing and connecting a WSS 53 Figure 13. GBIC Installation in 2380 Switch GBIC Figure 14. GBIC Removal from 2380 Switch Squeeze the lock clips to release GBIC To install a GBIC: 1 Insert the GBIC into a GBIC slot on the front panel until it clicks into place. 2 Remove the protective covering(s) from the port connector(s) and set them aside in a safe place for later use. 3 Insert the network cable. Note. For 1000BASE-SX or 1000BASE-LX fiber, make sure you insert the two cable ends in the proper sides (transmit or receive). Otherwise, the link does not work. Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

54 54 Installing and connecting a WSS 4 Observe the upper LED to the right of the GBIC port: If the LED is green, the 1000-Mbps link is operational. If the LED is blinking amber, traffic is active on the 1000-Mbps link. If the LED is unlit, the link is not operational. Check the cable and verify that the device at the other end of the link is operational. To remove a GBIC: 1 Remove the network cable(s). 2 Insert the protective covering(s) into the port connector(s). 3 Squeeze the clips on the sides of the GBIC and pull the GBIC out of the slot. NN ( D Version 01.02)

55 55 WSS technical specifications Table 10 lists the technical specifications for Nortel WLAN Security Switch (WSS) models Table 11 lists the technical specifications for model Table 12 lists the technical specifications for model (For detailed compliance information, consult the regulatory section and the Translations of Important Messages section of this installation guide. For specifications for the AP, see the Nortel Access Point Installation Guide.) Table Mechanical and Compliance Specifications Specification Description Size Width: 44.2 cm (17.4 inches) Depth: cm (18.2 inches) Height: 8.81 cm (3.47 inches) Weight With one power supply: 9.75 kg (21.50 pounds) With two power supplies: kg (25.00 pounds) Operating Temperature 0 C to +50 C (32 F to 122 F) Storage Temperature -20 C to +70 C (-4 F to +158 F) Humidity 10% to 95% noncondensing Power supply VAC 50 Hz to 60 Hz Up to 350 W 8A rms at 120 V rms and 3.5 A rms at 230 V rms, with 50-A peak inrush current Hot-swappable Load sharing with two supplies installed Status indicators Management CPU status LED Power supply status LEDs Port activity and link speed LEDs (For descriptions of the LEDs, see 2360, 2361 and 2380 LEDs on page 20.) Wired network ports Four dual-interface gigabit Ethernet ports. Each port has a 1000BASE-TX copper interface and a GBIC slot for insertion of a 1000BASE-SX or 1000BASE-LX fiber-optic interface. Safety and electromagnetic compliance FCC PART 15, UL ICES PART 15, CSA 22.2 NO EN 55022, EN CISPR 22 TUV/GS (EN ) VCCI Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

56 56 WSS technical specifications Table /2361 Mechanical and Compliance Specifications Specification Description Size Width: 44.2 cm (17.4 inches) Depth: 25.6 cm (10.08 inches) Height: 4.4 cm (1.72 inches) Weight Without a power supply: 3.40 kg (7.50 pounds) With one power supply: 3.8 kg (8.50 pounds) With two power supplies: 4.3 kg (9.50 pounds) Operating Temperature 0 C to +50 C (32 F to +122 F) Storage Temperature -20 C to +70 C (-4 F to +158 F) Humidity 10% to 95% noncondensing Power supply VAC / VAC 47 Hz to 63 Hz 2.5 A rms at 115 V rms and 1.25 A rms at 230 V rms, with 70-A peak inrush current Power over Ethernet (PoE) 48 VDC 91.8 W total budget for all ports (15.3 W * 6 ports) 15.3 W per port maximum Status indicators Power supply status LEDs Port activity and link speed LEDs (For descriptions of the LEDs, see 2360, 2361 and 2380 LEDs on page 20.) Wired network ports Six RJ-45 ports for 10/100BASE-T Ethernet and optional Power over Ethernet (PoE) Two RJ-45 ports for 10/100BASE-T Ethernet uplinks (without PoE) Safety and electromagnetic compliance FCC PART 15, UL ICES PART 15, CSA 22.2 NO EN 55022, EN CISPR 22 TUV/GS (EN ) VCCI NN ( D Version 01.02)

57 WSS technical specifications 57 Table Mechanical and Compliance Specifications Specification Description Size Width: 19.0 cm (7.5 inches) Depth: 14.6 cm (5.75 inches) Height: 3.18 cm (1.25 inches) Weight 0.7 kg (1.5 pounds) Operating Temperature 0 C to +50 C (32 F to +122 F) Storage Temperature -20 C to +70 C (-4 F to +158 F) Humidity 10% to 95% noncondensing Power supply Input: VAC, Hz, auto-sensing Output: 48 VDC, 0.83A Amperage draw maximums: At 115V (RMS): 0.8A At 230V (RMS): 0.4A Power over Ethernet (PoE) Voltage output: 48 VDC Wattage on port: 15.4 W Status indicators Power supply status LED Port activity and link speed LEDs Factory reset LED (For descriptions of the LEDs, see 2350 LEDs on page 21.) Wired network ports One RJ-45 port for 10/100BASE-T Ethernet and optional Power over Ethernet (PoE) One RJ-45 10/100BASE-T Ethernet uplink (without PoE) Safety and electromagnetic compliance FCC PART 15 Class A, UL ICES Class A, CSA 22.2 NO EN Class A, EN 55024, EN EN EU Medical Directive CISPR 22 Class A VCCI Class A Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

58 58 WSS technical specifications NN ( D Version 01.02)

59 59 WSS troubleshooting Table 13 contains remedies for some common problems that can occur during basic installation and setup of a WSS. Table 13: WSS Setup Problems and Remedies Symptom Diagnosis Remedy WLAN Management Software or a web browser (if you are using Web View) warns that the WSS s certificate date is invalid. WSS does not accept configuration information for an AP or a radio. The switch s time and date are currently incorrect, or were incorrect when you generated the self-signed certificate or certificate request. The country code might not be set or might be set for another country. 1. Use set timezone to set the time zone in which you are operating the switch. (See Setting the Time Zone in the the Nortel WLAN 2300 System Software Configuration Guide.) 2. Use set timedate to configure the current time and date in that time zone. (See Statically Configuring the System Time and Date in the Nortel WLAN 2300 System Software Configuration Guide.) 3. Reconfigure the administrative certificate(s). (See Creating Keys and Certificates in the in the Nortel WLAN 2300 System Software Configuration Guide.) 4. If you have already configured a certificate on the switch for authentication by network users, you must recreate this certificate, too. 1. Type the show system command to display the country code configured on the switch. 2. If the value in the System Countrycode field is NONE or is for a country other than the one in which you are operating the switch, use the set system countrycode command to configure the correct country code. (See Specifying the Country of Operation in the Nortel WLAN 2300 System Software Configuration Guide.) Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

60 60 WSS troubleshooting Client cannot access the network. Configuration information disappears after a software reload. Mgmt LED is quickly blinking amber. CLI stops at boot prompt (boot>). Table 13: WSS Setup Problems and Remedies (continued) Symptom Diagnosis Remedy This symptom has more than one possible cause: The client might be failing authentication or might not be authorized for a VLAN. If the client and switch configurations are correct, a VLAN might be disconnected. A client connected to a VLAN that is disconnected is unable to access the network. The configuration changes were not saved. The WSS was unable to load the system image file. 1. Type the show aaa command to check the authentication rules on the WSS, to ensure that the client can be authenticated. 2. Check the authorization rules in the switch s local database (show aaa) or on the RADIUS servers to ensure the client is authorized to join a VLAN that is configured on at least one of the WSS switches in the Mobility Domain. 1. Type the show vlan config command to check the status of each VLAN. 2. If a VLAN is disconnected (VLAN state is Down), check the network cables for the VLAN s ports. At least one of the ports in a VLAN must have a physical link to the network for the VLAN to be connected. 1. Retype the commands for the missing configuration information. 2. Type the save config command to save the changes. Type the boot command at the boot prompt. NN ( D Version 01.02)

61 Index 61 Numerics 10/100BASE-T BASE-LX BASE-SX BASE-TX A AC power inlet 19 advisory notices, explanations of 13 AP (Access Point) connections 50 LEDs 21, 51 authentication failure, troubleshooting 60 C cables network 39 serial console 38 certificates invalid, troubleshooting 59 clients, no network access, troubleshooting 60 configuration missing, troubleshooting 60 connections AP, requirements 40 LEDs 50, 52, 54 network 50 serial console 48 verifying, Ethernet 50 D verifying, serial console 49 documentation, product 12 E equipment rack installation 42 Ethernet connections, 10/100 Ethernet 50 connections, AP 50 connections, gigabit Ethernet 52 LEDs, 10/100 Ethernet 20, 50 LEDs, AP 21, 51 LEDs, gigabit Ethernet 20, 52, 54 Ethernet ports 19 F fans 37 flash card slot 19 front panel 16, 17 G GBICs (gigabit interface converters) 20 connecting 52 installing 52 LEDs 20 gigabit interface converters. See GBICs H hardware features 16 Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration

62 62 Index I installation equipment rack 42 GBICs 52 power supplies, requirements 37 requirements, AP connections 40 requirements, tools 16, 40 tabletop 44 troubleshooting 59 warnings, earth grounding 41 warnings, gigabit Ethernet fiber 38 warnings, overcurrent 41 warnings, service 15 invalid certificate, troubleshooting 59 L LEDs Link 51 link, 10/100 Ethernet 51 link, AP 51 link, gigabit Ethernet 52, 54 management CPU 20 power supply 20 links 10/100 Ethernet 51 AP 51 gigabit Ethernet 52, 54 LEDs 20 M manuals, product 12 model numbers 16 modem settings 48 N network cables 39 network connections 50 network plan, WMS 37 Nortel WLAN 2300 Series System 11 P ports Ethernet 19 power supplies 19 installation, LEDs 20 product documentation 12 R rack mount installation 42 restart switch 19 RF management 24 roaming 24 S safety notices, explanations of 13 serial console connection 48 settings 48 troubleshooting 49 serial console cable 38 serial console port 19 software features 23 specifications 55 status LEDs. See LEDs status lights. See LEDs switch. See WSS (WLAN Security Switch) system configuration missing, troubleshooting 60 system image file, incomplete load, troubleshooting 60 T tabletop installation 44 terminal emulator settings 48 tools required for installation 16, 40 troubleshooting blinking amber Mgmt LED 60 Ethernet links 50 incomplete boot load 60 installation and setup 59 NN ( D Version 01.02)

63 Index 63 U invalid certificate 59 missing configuration 60 serial console 49 users, no network access, troubleshooting 60 V VLANs (virtual LANs) authorization failure, troubleshooting 60 disconnected, troubleshooting 60 W warnings earth grounding 41 gigabit Ethernet fiber 38 installation 15 overcurrent 41 WLAN Security Switch. See WSS WMS network plan 37 work order, WMS 37 WSS (WLAN Security Switch) description of 16 front panel 17, 18 model numbers 16 specifications 55 troubleshooting 59 Nortel WLAN Security Switch 2300 Series Installation and Basic Configuration Guide

64 64 Index NN ( D Version 01.02)

65

66 Nortel WLAN 2300 Series Security Switch Installation and Basic Configuration Guide Nortel WLAN Security Switch 2300 Series Release 5.0 Document Number: NN Document Status: Standard Document Version: Part Code: D Release Date: May 2007 Copyright Nortel Networks Limited 2007 Alll Rights Reserved The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks. *Nortel, Nortel (Logo), the Globemark, and This is the way, This is Nortel (Design mark) are trademarks of Nortel Networks. *Microsoft, MS, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. All other trademarks and registered trademarks are the property of their respective owners. To provide feedback, or to report a problem in this document, go to

Installation-AC Power Supply

Installation-AC Power Supply NN46205-306 (312751-E Rev 02) Document status: Standard Document version: 0104 Document date: 4 April 2007 All Rights Reserved Sourced in Canada and the United States of America Nortel, the Nortel logo,

More information

Avaya Ethernet Routing Switch 3500 Series Regulatory Information

Avaya Ethernet Routing Switch 3500 Series Regulatory Information Avaya Ethernet Routing Switch 3500 Series Regulatory Information Release 5.2 NN47203-100 (700503193 Rev.03) Issue 03.01 February 2014 2014 Avaya Inc. All Rights Reserved. Notice While reasonable efforts

More information

Power Over Ethernet Adapters POE101

Power Over Ethernet Adapters POE101 Power Over Ethernet Adapters POE101 Installation Guide Introduction NETGEAR POE101 Power over Ethernet adapters are designed to supply operational power to devices through an Ethernet cable. These adapters

More information

USB Mini Print Server PS121. Installation Guide

USB Mini Print Server PS121. Installation Guide USB Mini Print Server PS121 Installation Guide Introduction Thank you for purchasing a NETGEAR PS121 USB Mini Print Server. With this print server you can share your printer with all the computers in your

More information

Hardware overview. Package contents MSM310, documentation, two 2.4-GHz (2-dBi) / 5-GHz (2-dBi) dual-mode omnidirectional antennas.

Hardware overview. Package contents MSM310, documentation, two 2.4-GHz (2-dBi) / 5-GHz (2-dBi) dual-mode omnidirectional antennas. VIEW Certified The MSM310 is a Wi-Fi Alliance authorized Wi-Fi CERTIFIED 802.11a/b/g product. The Wi-Fi CERTIFIED Logo is a certification mark of the Wi-Fi Alliance. The MSM310 is certified under the SpectraLink

More information

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide 4-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS104 Installation Guide 4500 Great America Parkway Santa Clara, CA 95054 USA Phone: 1-888-NETGEAR E-mail: [email protected] www.netgear.com Technical

More information

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105 5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105 Installation Guide Introduction The NETGEAR 5-Port Gigabit Ethernet Switch Model GS105 provides you with a low-cost, reliable, high-performance switch

More information

How To Use The Cisco Aironet 1240G Series For A Wireless Network (Wired) And For A Wired Network (Wireless)

How To Use The Cisco Aironet 1240G Series For A Wireless Network (Wired) And For A Wired Network (Wireless) Cisco Aironet 1240G Series Access Point Cisco Aironet 1240G Series Access Points provide single-band 802.11g wireless connectivity for challenging RF environments such as factories, warehouses, and large

More information

ProSAFE 8-Port and 16-Port Gigabit Click Switch

ProSAFE 8-Port and 16-Port Gigabit Click Switch ProSAFE 8-Port and 16-Port Gigabit Click Switch Model GSS108E and GSS116E User Manual March 2015 202-11520-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.

More information

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608 Installation Guide Introduction The NETGEAR 5/8-Port Gigabit Ethernet Switch Model GS605 / GS608 provides you with a high-speed, reliable, easy-to-use

More information

Wireless Router Setup Manual

Wireless Router Setup Manual Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,

More information

Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17

Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,

More information

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual HP-1000E v2 Powerline Ethernet Adapter User s Manual HP1000E v2 User s Manual Table of Contents Chapter 1: Introduction...1 Chapter 2: Planning your Powerline Network...1 Network Topology...1 Chapter 3:

More information

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev. Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of

More information

Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide

Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide Start Here Congratulations on your purchase of the NETGEAR Model EN104, Model EN108, or Model EN116 Ethernet hub. The hubs deliver standards-based, plugand-play networking solutions for small businesses,

More information

PRO 5000 CPE 1D Quick Installation Guide

PRO 5000 CPE 1D Quick Installation Guide PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product

More information

ATA User Manual. iinet ATA Telephone Adapter. Setting up for ADSL and VoIP. For model F1PG200ENau

ATA User Manual. iinet ATA Telephone Adapter. Setting up for ADSL and VoIP. For model F1PG200ENau ATA User Manual Please insert your installation CD now and then follow the on screen instructions iinet ATA Telephone Adapter Setting up for ADSL and VoIP. For model F1PG200ENau F1PG200ENau Table of Contents

More information

User Guide. Introduction. Contents. Models / Part Numbers. 100-Base-FX Network Interface Cards (NICs)

User Guide. Introduction. Contents. Models / Part Numbers. 100-Base-FX Network Interface Cards (NICs) User Guide 100-Base-FX Network Interface Cards (NICs) Introduction Transition Networks N-FX-xx-03 PCI 100FX NICs provide a 100Base-FX fiber port and delivers low cost, fiber optic connectivity to the desktop

More information

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP RouteFinder SOHO SOHO Security Appliance EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP Quick Start Guide RouteFinder RF825 Series Quick Start Guide RouteFinder SOHO Security Appliance

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents

More information

Technical Support. Support Information

Technical Support. Support Information Technical Support Please refer to the Support Information card that shipped with your product. By registering your product at www.netgear.com/register, we can provide you with faster expert technical support

More information

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220 Installation Guide Wireless N Access Point EAP110/EAP120/EAP220 CONTENTS Network Topology 01 Hardware Overview 02 Hardware Installation 05 1. Installation Requirements... 05 2. Mounting Bracket... 05

More information

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business Quick Start Guide Cisco Small Business WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide Versión en Español para México en el CD Version en français sur CD Versione

More information

MoCA Adapter MC1001 v2 Installation Guide

MoCA Adapter MC1001 v2 Installation Guide Technical Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product and use it to register your product at www.netgear.com/register.

More information

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches Quick Start Guide Cisco Small Business 200E Series Advanced Smart Switches Welcome Thank you for choosing the Cisco 200E series Advanced Smart Switch, a Cisco Small Business network communications device.

More information

Models HPE OfficeConnect M210 802.11n (WW) Access Point

Models HPE OfficeConnect M210 802.11n (WW) Access Point Overview Models HPE OfficeConnect M210 802.11n (AM) Access Point HPE OfficeConnect M210 802.11n (WW) Access Point JL023A JL024A Key features IEEE 802.11a/b/g/n access point (AP) Single-radio, dual-band

More information

Broadband Router ESG-103. User s Guide

Broadband Router ESG-103. User s Guide Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits

More information

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device

More information

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and

More information

Gateway Port Replicator User Guide

Gateway Port Replicator User Guide Gateway Port Replicator User Guide Using the Port Replicator Identifying features Connecting and disconnecting the port replicator 1 Using the Port Replicator Top Power button Component Icon Description

More information

Hardware Installation Guide HotPoint 5100 Access Point

Hardware Installation Guide HotPoint 5100 Access Point HotPoint Hardware Installation Guide HotPoint 5100 Access Point Published March 2014 (Revised 2015) 2014 Firetide, Inc. All rights reserved. Firetide, the Firetide logo, Reliable connectivity anywhere,

More information

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter Industrial 10/100/BASE-T to 100/BASE-X SFP Media Converter Physical Port 1-port 10/100/BASE-T RJ45 with auto MDI / MDI-X function 1 SFP interface, 100/BASE-X dual mode (auto detection) Layer 2 Features

More information

300Mbps Wireless N Gigabit Ceilling Mount Access Point

300Mbps Wireless N Gigabit Ceilling Mount Access Point Datasheet 300Mbps Wireless N Gigabit Ceilling Mount Access Point 120 Highlights Wireless N speed up to 300Mbps The Controller Software enables administrators to manage hundreds of s easily from any PC

More information

Network Management Card. Installation and Quick Start Manual

Network Management Card. Installation and Quick Start Manual Network Management Card Installation and Quick Start Manual Radio frequency interference Changes or modifications to this unit not expressly approved by the party responsible for compliance could void

More information

CM500 High Speed Cable Modem User Manual

CM500 High Speed Cable Modem User Manual User Manual February 2015 202-11472-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label

More information

Open Networking Adapter 1101GT Quick Install Guide

Open Networking Adapter 1101GT Quick Install Guide Open Networking Adapter 1101GT Quick Install Guide 2016 Avaya Inc. 1 NN48800-300 01-07 2016 Avaya Inc. All Rights Reserved. Notice While reasonable efforts have been made to ensure that the information

More information

300Mbps Wireless N Ceiling Mount Access Point

300Mbps Wireless N Ceiling Mount Access Point Datasheet Ceiling Mount Access Point 110 Highlights Wireless N speed up to 300Mbps Controller Software enables administrators to easily manage hundreds of s Supports passive PoE for convenient installation

More information

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide 16-port Gigabit Switch 10/100/1000 Mbps GS116 Installation Guide Introduction The NETGEAR 16-port Gigabit Switch Model GS116 provides you with a low-cost, reliable, high-performance switch to connect up

More information

CM400 High Speed Cable Modem User Manual

CM400 High Speed Cable Modem User Manual User Manual July 2015 202-11412-02 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of

More information

ProCurve Switch 2500 Series

ProCurve Switch 2500 Series The ProCurve Switch 2500 series consists of low-cost, stackable, managed 24- and 12-port switches with 10/100 auto-sensing per port and 2 open transceiver slots for Gigabit or 100Base-FX. ProCurve Switches

More information

C24-CAMANL Video Server/Encoder

C24-CAMANL Video Server/Encoder C24-CAMANL Video Server/Encoder User s Guide Table of Contents CHAPTER 1 INTRODUCTION... 1 Overview... 1 Physical Details - Video Server... 2 Package Contents... 3 CHAPTER 2 BASIC SETUP... 4 System Requirements...

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Cisco Small Business 500 Series Wireless Access Points

Cisco Small Business 500 Series Wireless Access Points Data Sheet Cisco Small Business 500 Series Wireless Access Points High-Performance, Easy-to-Deploy, Secure Business-Class Wireless-N Connectivity Highlights Provides cost-effective selectable or concurrent

More information

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the

More information

Wireless LAN Outdoor Bridge Solution

Wireless LAN Outdoor Bridge Solution 309-2273-001AA.fm Page 1 Monday, February 3, 2003 4:54 PM Quick Start Guide Wireless LAN Outdoor Bridge Solution 3CRWEASY96A Outdoor solution for secure long-distance wireless connections The 3Com Wireless

More information

Wireless Access Point AT-WA7400. Installation Guide. PN 613-000487 RevA

Wireless Access Point AT-WA7400. Installation Guide. PN 613-000487 RevA Wireless Access Point AT-WA7400 Installation Guide PN 613-000487 RevA Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission

More information

Networking Guide Redwood Manager 3.0 August 2013

Networking Guide Redwood Manager 3.0 August 2013 Networking Guide Redwood Manager 3.0 August 2013 Table of Contents 1 Introduction... 3 1.1 IP Addresses... 3 1.1.1 Static vs. DHCP... 3 1.2 Required Ports... 4 2 Adding the Redwood Engine to the Network...

More information

Chapter 1 Connecting the Router to the Internet

Chapter 1 Connecting the Router to the Internet Chapter 1 Connecting the Router to the Internet This chapter describes how to set up the router on your Local Area Network (LAN) and connect to the Internet. It describes how to set up your wireless ADSL

More information

RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket

RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket Rack-Mount Managed Gigabit PoE v1.2 / Dec, 2011 Features Supports O-Ring (recovery time < 30ms over 250 units of connection), MSTP/RSTP/STP (IEEE 802.1s/w/D) for Ethernet Redundancy Supports Jumbo frame

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

EtherDevice Switch EDS-726 Series

EtherDevice Switch EDS-726 Series Managed Redundant EtherDevice TM Switch Solutions EtherDevice Switch EDS-726 Series 26-Port Gigabit Ethernet Switch Modular, Managed, Redundant Features Industrial Networking Capability Redundant Gigabit

More information

RC8021 Indoor Camera Installation Guide

RC8021 Indoor Camera Installation Guide RC8021 Indoor Camera Installation Guide P/N: 957YL502GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owners i Package

More information

300Mbps Wireless N Gigabit Ceilling Mount Access Point

300Mbps Wireless N Gigabit Ceilling Mount Access Point Datasheet 300Mbps Wireless N Gigabit Ceilling Mount Access Point 120 Highlights Wireless N speed up to 300Mbps Clustering function greatly simplified business wireless network management, to easy manage

More information

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400 User Manual PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400 PePWave Mesh Connector Indoor Series: MC 200, E200, 400 PePWave Surf AP Series: Surf AP 200-X, E200-X, 400-X PePWave Surf

More information

HP ProCurve MultiService Access Point Series

HP ProCurve MultiService Access Point Series Product overview HP ProCurve MultiService Mobility Access Points (MSM APs) bring intelligence to the network edge by providing scalable, seamless wireless access anywhere, anytime. Their feature set is

More information

Chapter 4 Management. Viewing the Activity Log

Chapter 4 Management. Viewing the Activity Log Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in

More information

Cisco Aironet 1130G Series IEEE 802.11g Access Point

Cisco Aironet 1130G Series IEEE 802.11g Access Point Cisco Aironet 1130G Series IEEE 802.11g Access Point Low-profile business-class access point with integrated antennas for easy deployment in offices and similar RF environments Product Overview The Cisco

More information

Network Management Card

Network Management Card Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install

More information

How To Set Up An Andsl Modem Router For Internet Access

How To Set Up An Andsl Modem Router For Internet Access ADSL Modem Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10026-01 2006-2 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,

More information

WBS210/WBS510 Datasheet

WBS210/WBS510 Datasheet 2.4GHz/5GHz 300Mbps Outdoor Wireless / Datasheet Highlights Broad operating frequency channels ensure less wireless interference Wireless N speed up to 300Mbps Selectable bandwidth of 5/10/20/40MHz Adjustable

More information

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series EISK8M Series d a t a SHEET Skorpion Managed Ethernet Switch Series The EISK8M Series offers a compact rugged managed 10/100 Mbps Ethernet switch with a choice of eight copper ports or a mix of six copper

More information

Industrial Ethernet Switches

Industrial Ethernet Switches Managed μ-ring Switch Industrial Ethernet Switches IUS-3062GT/FX/GF IUS-3080 Port Number Number of ports 8 8 10/100 Base-T(X) RJ45 Ports 6 8 1000Base-T RJ45 Ports 2-100Base-FX Fiber Ports 2 (Muti/Single-Mode)

More information

User Guide. Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário WNA-100. Wireless Network Adapter

User Guide. Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário WNA-100. Wireless Network Adapter WNA-100 Wireless Network Adapter User Guide Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário www.xerox.com/office/wna Copyright 2007 Xerox Corporation. All Rights

More information

HP M220 802.11n Access Point Series

HP M220 802.11n Access Point Series Data sheet HP M220 802.11n Access Point Series Key features IEEE 802.11a/b/g/n access point Single-radio, dual-band (2.4 GHz or 5 GHz) Simplified wireless LAN administration with clustering technology

More information

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction IES-3080/3062 Series Features Industrial 8-port managed Ethernet switch Fastest Redundant Ethernet Ring: O-Ring (recovery time < 10ms over 250 units of connection) Open-Ring supports the other vendor s

More information

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide. 613-001352 Rev. A

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide. 613-001352 Rev. A Gigabit eco-friendly Ethernet Switch AT-GS900/8 Installation Guide 613-001352 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior

More information

QuickSpecs. HP M220 802.11n Access Point Series. Models HP M220 802.11n WW Access Point. Key features

QuickSpecs. HP M220 802.11n Access Point Series. Models HP M220 802.11n WW Access Point. Key features Overview HP M220 802.11n Access Point Series Models HP M220 802.11n AM Access Point HP M220 802.11n WW Access Point J9798A J9799A Key features IEEE 802.11a/b/g/n access point Single-radio, dual-band (2.4

More information

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W GEP-5070 Version: 1 48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W The LevelOne GEP-5070 is an intelligent L2 Managed Switch with 48 x 1000Base-T PoE-Plus ports and 2 x 100/1000BASE-X SFP (Small Form

More information

TSM Series Serial Console Servers. RSM Series Remote Site Managers. RSM-xRy Series Remote Site Managers with Power Control.

TSM Series Serial Console Servers. RSM Series Remote Site Managers. RSM-xRy Series Remote Site Managers with Power Control. WTI Part No. 14023 Rev. O TSM Series Serial Console Servers RSM Series Remote Site Managers RSM-xRy Series Remote Site Managers with Power Control Products Covered: TSM Series RSM Series RSM-xRy Series

More information

HP AP8760 Dual Radio 802.11a/b/g Access Point Overview

HP AP8760 Dual Radio 802.11a/b/g Access Point Overview Overview Models JD016A Key features Simultaneous 802.11a and 802.11b/g support PoE power/data via Category 5/6 data cables WPA/2, AES, TKIP, WEP packet encryption MAC address authentication/filtering WDS

More information

N300 WiFi Range Extender WN2000RPT User Manual

N300 WiFi Range Extender WN2000RPT User Manual N300 WiFi Range Extender WN2000RPT User Manual December 2013 202-11333-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device,

More information

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide Symantec Database Security and Audit 3100 Series Appliance Getting Started Guide Symantec Database Security and Audit 3100 Series Getting Started Guide The software described in this book is furnished

More information

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com

More information

MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz)

MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz) MAX-306M1 Series Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz) WiMAX MIMO Outdoor Simple CPE Firmware v3.70 Edition 2, 12/2009 DEFAULT LOGIN DETAILS IP Address: Username: http://192.168.1.1 admin

More information

10/2011 - English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point

10/2011 - English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point 10/2011 - English Edition 1 Quick Start Guide NWA1100N-CE CloudEnabled Business N Wireless Access Point Package Contents - 1 x ZyXEL NWA1100N-CE Access Point - 2 x Detachable Antennas - 1 x Power Adapter

More information

Key Features. EnGenius Outdoor Base Station designs High Power, High Sensitivity and Strong Reliability Solutions under Harsh Environment.

Key Features. EnGenius Outdoor Base Station designs High Power, High Sensitivity and Strong Reliability Solutions under Harsh Environment. 802.11 b/g/n N300 Access Point Key Features IEEE 802.11 b/g/n compliant Up to 300Mbps (2.4GHz) Complaint with IEEE 802.3 at for PoE supported PoE injector with reset from remote-end Two Gigabit Ethernet

More information

100 240VAC 50/60Hz Power Adapter

100 240VAC 50/60Hz Power Adapter DGS-1224T D-Link 24-Port 10/100/1000Mbps + 2 Combo Mini GBIC Gigabit Smart Switch Broadband Router Before Your Begin This Quick Installation Guide gives step-by-step instructions for setting up the D -Link

More information

ProCurve Switch 8000m (J4110A) and Switch 8000m

ProCurve Switch 8000m (J4110A) and Switch 8000m ProCurve Switch 4000m and Switch 8000m The ProCurve Switch 4000m and 8000m are managed modular 10/100/1000 desktop switches that provide scalable, expandable, low-cost migration to 10/100 switching for

More information

POTS 2-Wire to Fiber Converter TE160A, TE161A, TE162A TE163A, TE164A, TE165A User s Guide

POTS 2-Wire to Fiber Converter TE160A, TE161A, TE162A TE163A, TE164A, TE165A User s Guide POTS 2-Wire to Fiber Converter TE160A, TE161A, TE162A TE163A, TE164A, TE165A User s Guide The Black Box POTS 2-Wire to Fiber Converter (P/N TE16xA) connects centraloffice voice-grade signals to distant

More information

NXC5200/ NWA5000-N Series Wireless LAN Controller/ 802.11 a/b/g/n Managed Access Point

NXC5200/ NWA5000-N Series Wireless LAN Controller/ 802.11 a/b/g/n Managed Access Point Higherbandwidth, higher density with full range of 802.11n s (NWA5000N Series) Comprehensive guest network management with auto guest account generator and Web authentication support Manage up to 240 APs

More information

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches Quick Start Guide Cisco Small Business 200 Series 8-Port Smart Switches Welcome Thank you for choosing the Cisco 200 Series 8-Port Smart Switch, a Cisco Small Business network communications device. This

More information

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P. www.tp-link.com

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P. www.tp-link.com Power Budget TP-LINK 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots Overview The provides 24 10/100/1000Mbps ports that supports 802.3at/af-compliant PoE, with a total PoE power supply up to 180W,

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 1.6 Page 1 Publication Revision No. Control Table Rev. No. Date Contents 1.6 8/22/07 Support connection of multiple WM5.0 devices 1.5 6/18/07 Support

More information

10BASE-T/100BASE-TX & 100BASE-FX 2-Port Bridging Media Converter

10BASE-T/100BASE-TX & 100BASE-FX 2-Port Bridging Media Converter 12 COMPLIANCE INFORMATION UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital

More information

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual ALL8808POE 8 Port Gigabit PoE+ Switch Manual FCC Certifications This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These

More information

Enterprise WiFi System. Datasheet. Models: UAP, UAP-LR, UAP-Outdoor, UAP-Mini. Unlimited Indoor/Outdoor AP Scalability in a Unified Management System

Enterprise WiFi System. Datasheet. Models: UAP, UAP-LR, UAP-Outdoor, UAP-Mini. Unlimited Indoor/Outdoor AP Scalability in a Unified Management System Enterprise WiFi System Models: UAP, UAP-LR, UAP-Outdoor, UAP-Mini Unlimited Indoor/Outdoor AP Scalability in a Unified Management System 150-300 Mbps 802.11b/g/n WiFi Technology Intuitive UniFi Controller

More information

Powerline 1200 User Manual

Powerline 1200 User Manual User Manual Models PL1200 PLP1200 January 2016 202-11566-01 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product.you can visit www.netgear.com/support to register

More information

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start mysensors Information to Users mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant

More information

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s (9900-003-001-A, 9900-002-001-A) Manual

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s (9900-003-001-A, 9900-002-001-A) Manual SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s (9900-003-001-A, 9900-002-001-A) Manual Notes Before installing and putting the device into operation, please read the security guidelines

More information

1Industrial Ethernet Switch

1Industrial Ethernet Switch Ethernet Switch DIN-Rail Managed Ethernet Switch v2.0/ Dec, 2011 IES-3080/3062 Series Features 8-port managed Ethernet switch 1 Ethernet Switch Fastest Redundant Ethernet Ring: O-Ring (recovery time

More information

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS

More information

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch Rev: 1.1.0 7106503251 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark

More information

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: US-24-250W, US-24-500W, US-48-500W, US-48-750W

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: US-24-250W, US-24-500W, US-48-500W, US-48-750W Managed PoE+ Gigabit es with SFP Models: US-24-25W, US-24-5W, US-48-5W, US-48-75W Non-Blocking Throughput ing Performance Gigabit Ethernet RJ45 and SFP+/SFP Ports Auto-Sensing IEEE 82.3af/at PoE Build

More information

Enterprise WiFi System. Datasheet. Models: UAP, UAP-LR, UAP-Pro, UAP-Outdoor, UAP-Outdoor5

Enterprise WiFi System. Datasheet. Models: UAP, UAP-LR, UAP-Pro, UAP-Outdoor, UAP-Outdoor5 Enterprise WiFi System Models: UAP, UAP-LR, UAP-Pro, UAP-Outdoor, UAP-Outdoor5 Unlimited Indoor/Outdoor AP Scalability in a Unified Management System Breakthrough Capacity up to 750 Mbps Intuitive UniFi

More information