Hitachi Unified Storage VM Block Module
|
|
|
- Jason Adams
- 9 years ago
- Views:
Transcription
1 Hitachi Unified Storage VM Block Module Hitachi SNMP Agent User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92HM
2 Hitachi, Ltd. All right reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi, Ltd. (hereinafter referred to as "Hitachi"), and Hitachi Data Systems Corporation (hereinafter referred to as "Hitachi Data Systems"). Hitachi and Hitachi Data Systems reserve the right to make changes to this document at any time without notice and assume no responsibility for its use. This document contains the most current information available at the time of publication. When new or revised information becomes available, this entire document will be updated and distributed to all registered users. All of the features described in this document may not be currently available. Refer to the most recent product announcement or contact your local Hitachi Data Systems sales office for information about feature and product availability. Notice: Hitachi Data Systems products and services can be ordered only under the terms and conditions of Hitachi Data Systems' applicable agreements. The use of Hitachi Data Systems products is governed by the terms of your agreements with Hitachi Data Systems. Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. Hitachi Data Systems is a registered trademark and service mark of Hitachi in the United States and other countries. ShadowImage and TrueCopy are registered trademarks of Hitachi Data Systems. AIX and IBM are registered trademarks or trademarks of International Business Machines Corporation. All other trademarks, service marks, and company names are properties of their respective owners. Microsoft product screen shots are reprinted with permission from Microsoft Corporation. ii
3 Contents Preface v Intended audience vi Product version vi Document revision level vi Changes in this revision vi Referenced documents vi Conventions vi Convention for storage capacity values vii Accessing product documentation viii Getting help viii Comments viii 1 Introduction SNMP Manager overview SNMP Manager and SNMP Agent interaction Management Information base SNMP Agent configuration SNMP Agent functions SNMP traps SNMP Agent operations Error report Component status information from SNMP Manager Resources that can be executed for each function Using SNMP Managing SNMP IP addresses Adding an SNMP Manager IP address Deleting an SNMP Manager IP address Managing community names Adding a community name Deleting a community name iii
4 Changing a community name Managing community IP addresses Adding a community IP address Deleting a Community IP address Testing the SNMP trap report SNMP supported MIBs Trap configuration Failure report trap Supported traps Standard MIB specifications Supported MIBs MIB access mode Object identifier system MIB mounting specifications Extension MIB specifications raidexmibname raidexmibversion raidexmibagentversion raidexmibdkccount raidexmibraidlisttable raidexmibdkchwtable raidexmibdkuhwtable raidexmibtraplisttable Extension MIB configuration SNMP failure trap reference SNMP failure trap reference codes Troubleshooting Getting help Solving SNMP problems A SNMP GUI reference A-1 SNMP Information window A-2 Glossary Index iv
5 Preface This manual provides instructions and information to use the Hitachi SNMP Agent on the Hitachi Unified Storage VM (HUS VM). This preface includes the following information. Intended audience Product version Document revision level Changes in this revision Referenced documents Conventions Convention for storage capacity values Accessing product documentation Getting help Comments Preface v
6 Intended audience Product version This document is intended for system administrators, HDS representatives, and authorized service providers who are involved in installing, configuring, and operating the Hitachi Unified Storage VM (HUS VM) storage system. Readers of this document should be familiar with the following: A background in data processing and an understanding of RAID storage systems and their basic functions. Familiarity with the Hitachi Unified Storage VM storage system and the Hitachi Unified Storage VM Block Module Hardware User Guide. Familiarity with the Storage Navigator software for the Hitachi Unified Storage VM and the Hitachi Storage Navigator User Guide. Familiarity with the operating system and web browser software on the system hosting the Storage Navigator software. This document revision applies to Hitachi Unified Storage VM microcode x and later. Document revision level Changes in this revision Added trap reference codes to Table 4-1 SNMP failure trap reference codes on page 4-2 Referenced documents Conventions Revision Date Description MK-92HM September 2012 Initial release. MK-92HM December 2012 Supersedes and replaces MK-92HM MK-92HM March 2013 Supersedes and replaces MK-92HM MK-92HM October 2013 Supersedes and replaces MK-92HM Hitachi Unified Storage VM: Hitachi Unified Storage VM Block Module Hardware User Guide, MK- 92HM7005 This document uses the following typographic conventions: vi Preface
7 Convention Description Bold Italic Indicates the following: Text in a window or dialog box, such as menus, menu options, buttons, and labels. Example: On the Add Pair dialog box, click OK. Text appearing on screen or entered by the user. Example: The -split option. The name of a directory, folder, or file. Example: The horcm.conf file. Indicates a variable, which is a placeholder for actual text provided by the user or system. Example: copy source-file target-file Angle brackets are also used to indicate variables. Monospace Indicates text that is displayed on screen or entered by the user. Example: # pairdisplay -g oradb < > angle brackets Indicates a variable, which is a placeholder for actual text provided by the user or system. Example: # pairdisplay -g <group> Italic is also used to indicate variables. [ ] square brackets Indicates optional values. Example: [ a b ] indicates that you can choose a, b, or nothing. { } braces Indicates required or expected values. Example: { a b } indicates that you must choose either a or b. vertical bar Indicates that you have a choice between two or more options or arguments. Examples: [ a b ] indicates that you can choose a, b, or nothing. { a b } indicates that you must choose either a or b. This document uses the following icons to draw attention to information: Icon Meaning Description Tip Helpful information, guidelines, or suggestions for performing tasks more effectively. Note Calls attention to additional information. Caution WARNING Failure to take or avoid a specified action can result in adverse conditions or consequences (for example, loss of access to data). Failure to take or avoid a specified action can result in severe conditions or consequences (for example, loss of data). Convention for storage capacity values Physical storage capacity values (for example, disk drive capacity) are calculated based on the following values: Preface vii
8 Physical capacity unit Value 1 KB 1,000 (10 3 ) bytes 1 MB 1,000 KB or 1,000 2 bytes 1 GB 1,000 MB or 1,000 3 bytes 1 TB 1,000 GB or 1,000 4 bytes 1 PB 1,000 TB or 1,000 5 bytes 1 EB 1,000 PB or 1,000 6 bytes Logical storage capacity values (for example, logical device capacity) are calculated based on the following values: Logical capacity unit Value 1 KB 1,024 (2 10 ) bytes 1 MB 1,024 KB or 1,024 2 bytes 1 GB 1,024 MB or 1,024 3 bytes 1 TB 1,024 GB or 1,024 4 bytes 1 PB 1,024 TB or 1,024 5 bytes 1 EB 1,024 PB or 1,024 6 bytes Accessing product documentation Getting help Comments The Unified Storage VM user documentation is available on the Hitachi Data Systems Portal: Check this site for the most current documentation, including important updates that may have been made after the release of the product. The Hitachi Data Systems customer support staff is available 24 hours a day, seven days a week. If you need technical support, log on to the Hitachi Data Systems Portal for contact information: Please send us your comments on this document: [email protected]. Include the document title and number, including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems. Thank you! viii Preface
9 1 Introduction This topic provides an overview of the SNMP implementation for monitoring the Hitachi Unified Storage VM, including the agent and management functions. SNMP Manager overview SNMP Agent configuration Component status information from SNMP Manager Resources that can be executed for each function Introduction 1 1
10 SNMP Manager overview SNMP Manager is installed in the network management station. It collects and manages information from SNMP agents installed in the managed devices on the network. The SNMP Manager graphically displays information collected from two or more SNMP agents, accumulates the information in the database, and analyzes problems discovered while accumulating this information. SNMP Manager and SNMP Agent interaction Figure 1-1 Example SNMP environment Simple Network Management Protocol (SNMP) is an industry-standard protocol for managing and monitoring network devices, including disk devices, routers, and hubs. SNMP uses Simple Gateway Management Protocol (SGMP) to manage TCP/IP gateways. An SNMP manager monitors the devices, which are referred to as managed nodes. Typically, an SNMP Manager polls the SNMP agents on a periodic basis. The manager receives the reports from the agents and determines whether the devices are operating normally. If an abnormal event occurs, an SNMP Agent can report the condition without a request from the manager, by using a trap message. The network management station can collect the status (information) of all managed nodes. This information can be examined to determined if an abnormal event has occurred. When an SNMP manager polls an agent, the following dialogue takes place: An SNMP Manager sends a request packet to an SNMP Agent, which requests data regarding the status of the managed node. The SNMP Agent sends a response packet back to the SNMP Manager. 1 2 Introduction
11 SNMP uses the TCP/IP User Datagram Protocol (UDP). If the SNMP Agent does not respond within a specified time period, the SNMP Manager resends the request packet. That time period is set by the system administrator, taking into account the network traffic and operation policy. If an SNMP Agent again does not respond to the resent packet, the SNMP Manager assumes that an error has occurred. Depending on the times set for polling and response, this can take several seconds. If an SNMP Agent detects an abnormal event, it sends a trap to the SNMP Manager. However, if a trap is dropped in transmission, the SNMP Manager does not know that it was sent. For this reason, you should use both polling and traps to determine whether an abnormal event has occurred. Management Information base The standardized configuration and database of network management information is called a Management Information Base (MIB). A standard MIB is common to all SNMP interfaces. An extension MIB is defined by the particular managed device or protocol. A MIB is a collection of standardized configuration and network management information that is contained in each device on the network. Each MIB contains a set of parameters called managed objects. Each managed object consists of a parameter name, one or more parameters, and a group of operations that can be executed with the object. The MIB defines the type of information that can be obtained from a managed device, and the device settings that can be controlled from a management system. SNMP Agent configuration The Hitachi Unified Storage VM SNMP Agent is installed on the SVP, which is the computer within the storage array that manages the storage system. The Unified Storage VM has an exclusive LAN for communications between a storage system and the SVP, and a separate LAN for SNMP. The configuration of each Network Management Station is determined by the type of SNMP Manager. Figure 1-2 SNMP environment architecture on page 1-4 illustrates the SNMP environment. Figure 1-3 Example of SNMP operations on page 1-4 shows an example of SNMP operations by using an SNMP Manager. Introduction 1 3
12 Figure 1-2 SNMP environment architecture SNMP Agent functions SNMP traps Figure 1-3 Example of SNMP operations The SNMP Agent is mounted on the managed device (hard disk, etc.) in the network. It collects error information, the usage condition, and other information about the device, and forwards the information to the SNMP Manager. The SNMP Agent reports storage system failures to the manager using the functions described in the following paragraphs. An SNMP Agent uses the SNMP trap function to report a storage system error to the SNMP Manager. If an error occurs, an SNMP Agent issues an SNMP trap that reports the failure to an SNMP Manager. When issuing an SNMP trap, an SNMP Agent also reports a product number, nickname, reference code, and an identifier of the component. The following table lists the events that trigger an SNMP Agent trap. 1 4 Introduction
13 Table 1-1 SNMP Agent events Events Acute failure detected. Serious failure detected. Moderate failure detected. Service failure detected. Description All operations in a storage system stopped. Operation in a component where a failure occurred stopped. Partial failure. Minor failure. An SNMP Agent logs the most recent 256 traps, so you can see the trap history of a particular device. SNMP Agent operations The following table lists the types of SNMP Agent operations. Table 1-2 Types of SNMP Agent operations Operation GET GETNEXT TRAP Description Obtains a specific MIB object value. GET REQUEST is the request from an SNMP Manager, and GET RESPONSE is the agent's response to that request. Continuously finds a MIB object. GETNEXT REQUEST is the request from an SNMP Manager, and GETNEXT RESPONSE is the agent's response to that request. Reports an event (failure) to an SNMP Manager. TRAP occurs without a request from the SNMP Manager. Error report The following table lists the errors to be reported for the REQUEST operations. Table 1-3 REQUEST operation errors Error Description Corrective action noerror (0) Normal N/A nosuchname (2) There are no MIB objects that are required. (Not supported.) The GETNEXT REQUEST command that is specified for the following object identifier of the last supported MIB object is received. Verify that the name of the requested object is correct. readonly (4) SET REQUEST is received. SET operation is not supported. generr (5) Error occurred for other reasons. Retry the operation. Introduction 1 5
14 Component status information from SNMP Manager You can obtain the status information of certain storage system components from the SNMP Manager. The following table lists the components for which the status can be obtained. Table 1-4 Storage system components Area Component name Storage System DB Processors BUS Cache Shared memory Power supplies Batteries Fans Others Power supplies Fans Hard disks Others The following table lists the status of storage system components, as well as the trap report functions. Table 1-5 Storage system component status Status Normal Acute failure detected Serious failure detected Moderate failure detected Service failure detected Description Normal operation. All operations in a storage system stopped. Operation in a component where a failure occurred stopped. Partial failure. Minor failure. Resources that can be executed for each function Storage Navigator secondary window shows all the resources in the storage system. However, the functions described in this manual are only available to the resources that are assigned to a user account who logs into the Storage Navigator. Verify the resource group ID in the Basic Information Display dialog boxes, and then execute the operations for the resources assigned to the user account. When you use the functions, the resources for each operation must satisfy the specific conditions. For details on user accounts, see Hitachi Storage Navigator User Guide. For details on the conditions of the resources, see the Hitachi Unified Storage VM Block Module Provisioning Guide. 1 6 Introduction
15 2 Using SNMP This topic describes how to use Storage Navigator to manage SNMP Manager IP addresses, community names, and community IP addresses. It also explains how to test SNMP trap reports. Managing SNMP IP addresses Managing community names Managing community IP addresses Testing the SNMP trap report Using SNMP 2 1
16 Managing SNMP IP addresses Adding an SNMP Manager IP address Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. In the Storage Navigator main window, click Settings > Environmental Setting > SNMP Information in the Storage Navigator menu bar. The SNMP Information window appears. 3. Click the Mode Change icon ( ) to change to Modify mode. 4. In the SNMP Information window, click Extension SNMP. 5. Select IPv4 or IPv6 and specify the version of the IP address you enter. Note: In SVP, Windows does not support IPv6. If the SVP OS is Windows and you enter the IPv6 address and click Apply, an error message is displayed and the IPv6 address is not set. 6. Enter the desired IP address in the IP Address text box. 2 2 Using SNMP
17 7. Click Set. The new IP address is added to the IP Address list, but the changes are not yet saved. 8. Click Apply to save the changes. A confirmation message is displayed. 9. In the confirmation message box, click OK to confirm the changes or Cancel to exit without saving the changes. Deleting an SNMP Manager IP address Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. Click the Mode Change icon ( ) to change to Modify mode. 3. In the Storage Navigator main window, click Settings > Environmental Setting > SNMP Information in the menu bar. The SNMP Information window is displayed. 4. In the SNMP Information window, click Extension SNMP (check box). 5. In the IP Address list box, select one or more unwanted IP addresses. Right-click the IP address to display the Delete IP Address menu. Using SNMP 2 3
18 6. Click Delete IP Address. 7. A confirmation message is displayed. Select OK to delete the IP address, or Cancel to exit the dialog box without deleting the IP address. 8. In the SNMP Information window, click Apply to save the changes. A confirmation message is displayed. 9. In the confirmation message box, click OK to confirm the changes or click Cancel to exit without saving the changes. Managing community names Adding a community name Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. In the Storage Navigator menu bar, click Settings > Environmental Setting > SNMP Information. The SNMP Information window is displayed. 3. Click the Mode Change icon ( ) to change to Modify mode. 4. In the SNMP Information window, click Extension SNMP (check box). The Community & Trap dialog box is displayed. 5. In the Community & Trap dialog box, right-click Community. The Add Community menu is displayed. 6. Select Add Community. The Add Community dialog box is displayed. 2 4 Using SNMP
19 7. In the Community field, enter the desired community name. You can enter up to 180 alphanumeric characters. The following special characters are not allowed: ", \, ;, :,,, *,?, <, >,, /, ^, &, and %. 8. Click OK. The new community name is displayed in the Community & Trap dialog box, but the changes are not yet implemented in the storage system. 9. To add one or more IP addresses to the new community, see Adding a community name on page Click Apply to save the changes. A confirmation message is displayed. 11.In the confirmation message box, click OK to confirm the changes or Cancel to exit without saving the changes. Deleting a community name Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. In the Storage Navigator menu bar, click Settings > Environmental Setting > SNMP Information. The SNMP Information window is displayed. 3. Click the Mode Change icon ( ) to change to Modify mode. 4. In the SNMP Information window, click Extension SNMP (check box). The Community & Trap dialog box is displayed. 5. In the Community & Trap dialog box, right-click Community. The Delete Community menu is displayed. 6. Select Delete Community. A confirmation message is displayed. Using SNMP 2 5
20 7. Click OK. The selected community is deleted from the Community & Trap list, but the settings are not yet saved. 8. Click Apply to save the changes. A confirmation message is displayed. 9. In the confirmation message box, click OK to confirm the changes or Cancel to exit without saving the changes. Changing a community name Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. In the Storage Navigator menu bar, click Settings >Environmental Setting > SNMP Information. The SNMP Information window is displayed. 3. Click the Mode Change icon ( ) to change to Modify mode. 4. In the SNMP Information window, click Extension SNMP (check box). 5. In the Community & Trap dialog box, select and then right-click the community name that you want to change. The Change Community menu is displayed. 6. Select Change Community. The Change Community dialog box is displayed. 7. In the Community field, overwrite the old community name with a new community name. You can use up to 180 alphanumeric characters, except for ", \, ;, :,,, *,?, <, >,, /, ^, &, and %. 8. Click OK. The changed community name is displayed in the Community & Trap dialog box, but the changes are not yet saved. 2 6 Using SNMP
21 9. Click Apply to save the changes. A confirmation message is displayed. 10.In the confirmation message box, click OK to confirm the changes or Cancel to exit without saving the changes. Managing community IP addresses Adding a community IP address This section describes the procedure to add a community IP address: Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. In the Storage Navigator menu bar, click Settings > Environmental Setting > SNMP Information. The SNMP Information window is displayed. 3. Click the Mode Change icon ( ) to change to Modify mode. 4. In the SNMP Information window, click Extension SNMP (check box). The Community & Trap dialog box is displayed. 5. In the Community & Trap dialog box, right-click the desired community. The Add Community menu is displayed. 6. Select Add IP Address. The Add IP Address dialog box is displayed. 7. In the IP Address field, enter a new IP address or select an existing IP address. If the values for an IP address are all set to zero (0), then that address cannot be specified for IPv4 and IPv6. The Add IP Address dialog box does not support shortened expression of the IPv6 address. Enter 8 hexadecimal numbers that are separated by colons (:) to a maximum 4 digits from zero (0) to FFFF inclusive. Using SNMP 2 7
22 Note: In SVP, Windows does not support IPv6. If the SVP OS is Windows XP and you enter the IPv6 address and click Apply, an error message is displayed and the IPv6 address is not set. 8. Click OK. The changed community name is displayed in the Community & Trap dialog box, but the changes are not yet saved. 9. Click Apply to save the changes. A confirmation message is displayed. 10.In the confirmation message box, click OK to confirm the changes or Cancel to exit without saving the changes. Deleting a Community IP address Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. In the Storage Navigator menu bar, click Settings > Environmental Setting > SNMP Information. The SNMP Information window is displayed. 3. Click the Mode Change icon ( ) to change to Modify mode. 4. In the SNMP Information window, click Extension SNMP (check box). The Community & Trap dialog box is displayed. 5. In the Community &Trap dialog box, select the unwanted community IP address. Right-click to display the Delete IP Address menu. 6. Select Delete IP Address. A confirmation message is displayed. 7. Click OK. The changed community name is deleted from the Community & Trap dialog box, but the changes are not yet saved. 8. Click Apply to save the changes. A confirmation message is displayed. 9. In the confirmation message box, click OK to confirm the changes or Cancel to exit without saving the changes. 2 8 Using SNMP
23 Testing the SNMP trap report Prerequisite: You must have Storage Administrator privileges to perform this task. 1. Launch Storage Navigator and log in. 2. In the Storage Navigator menu bar, click Settings > Environmental Setting > SNMP Information. The SNMP Information window is displayed. 3. Click the Mode Change icon ( ) to change to Modify mode. 4. In the SNMP Information window, click Extension SNMP (check box). The Community & Trap dialog box is displayed. 5. Select Trap Test. A confirmation message is displayed. 6. Select OK. Verify whether the SNMP trap report (reference code 7FFFFF) is received by the SNMP manager registered in the community. Using SNMP 2 9
24 2 10 Using SNMP
25 3 SNMP supported MIBs This topic describes the standard and extension MIB specifications, the SNMP GUI, and trap configuration. Trap configuration Supported traps Standard MIB specifications Extension MIB specifications Extension MIB configuration SNMP supported MIBs 3 1
26 Trap configuration Failure report trap An extension trap protocol data unit (PDU) includes the product number of the device that experienced the failure, the device nickname, and a failure reference code. If you obtain the information with GetRequest command, access the MIB by using the product number of the device as an index. The following table shows the failure report trap. Table 3-1 Failure report trap Name Object identifier Type Description eventtrapserialn umber eventtrapnickna me eventtraprefco DE eventtrappartsi D INTEGER The product number of the device that experienced the failure DisplayString The device nickname DisplayString The failure reference OBJECT IDENTIFIER The area where the failure occurred.* eventtrapdate DisplayString Failure occurrence date. eventtraptime DisplayString Failure occurrence time. eventtrapdescri ption DisplayString Detailed information of a failure. *The object identifier for a failure in a storage system processor would be Supported traps The following table lists the supported extension trap types. Table 3-2 Extension trap types Specific Trap Code Trap Description 1 RaidEventUserAcute All operations in a storage system stopped. 2 RaidEventUserSerious Operation in a component where a failure occurred stopped. 3 RaidEventUserModerate Partial failure. 4 RaidEventUserService Minor failure. 3 2 SNMP supported MIBs
27 Standard MIB specifications Supported MIBs The following table lists the supported MIBs. If you send a GET request for an object (MIB) that is not supported, you will receive NoSuchName as a GET RESPONSE. Table 3-3 Supported MIBs MIB Supported? MIB access mode Standard MIB: MIB-II system group Yes interface group No at group No ip group No icmp group No tcp group No udp group No egp group No snmp group No Extension MIB Yes The access mode for MIB in all communities is read only. If you send a GET request for a SET operation, you will receive NoSuchName as a GET RESPONSE. An example object system supported by an SNMP Agent is shown the following figures. Object identifier system Figure 3-1 Object system (1) SNMP supported MIBs 3 3
28 Figure 3-2 Object system (2) *1: The HUS VM SNMP extended MIB MIB mounting specifications Figure 3-3 Object system (3) The supported MIB mounting specifications are as follows: mgmt OBJECT IDENTIFIER ::= {iso(1) org(3) dod(6) internet(1) 2 } mib-2 OBJECT IDENTIFIER ::= {mgmt 1} An SNMP Agent mounts only system groups in mib-2, as shown in the following. Table 3-4 System groups Name Description Mounted value sysobjectid {system 2} sysuptime {system 3} syscontact {system 4} This is the product identification number. An accumulated time from an SNMP agent. A manager who manages an agent or a contact address. Fixed value. See Object identifier system on page Unit: ms Maximum 180 characters in an ASCII characters string. Input by a user from an SNMP setting window.* 3 4 SNMP supported MIBs
29 Name Description Mounted value sysname {system 5} syslocation {system 6} The name of an agent manager An agent setup location. Extension MIB specifications Maximum 180 characters in an ASCII characters string. Input by a user from an SNMP setting window.* Maximum 180 characters in an ASCII characters string. Input by a user from an SNMP setting window.* sysservice Value indicating a service. Fixed value 76 (decimal) {system 7} *The following symbols cannot be used: \, / : ; *? " < > & % ^ The following shows the Extension MIB configuration. raidexmibroot(1) -raidexmibname(1) SVP product name -raidexmibversion(2) SVP Micro-program version -raidexmibagentversion(3) Extension MIB internal version -raidexmibdkccount(4) Number of DKC under the control of SVP -raidexmibraidlisttable(5)list of DKC under the control of SVP -raidexmibdkchwtable(6) Disk control device information -raidexmibdkuhwtable(7) Disk device information -raidexmibtraplisttable(8)error information list raidexmibname raidexmibversion raidexmibname indicates the SVP product name. raidexmibname OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "SVP product name." OID ::={ raidexmibroot 1 } raidexmibversion indicates the micro-program version. raidexmibagentversion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "SVP micro-program version." OID ::= { raidexmibroot 2 } raidexmibagentversion raidexmibagentversion indicates the internal version of the extension MIB. SNMP supported MIBs 3 5
30 raidexmibdkccount raidexmibdkccount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Extension agent version." OID ::= { raidexmibroot 3 } raidexmibdkccount suggests the number of a storage system under the control of the SVP. raidexmibdkccount OBJECT TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Registered subsystem number" OID ::={ raidexmibroot 4} raidexmibraidlisttable raidexmibraidlisttable indicates the storage system under the control of the SVP. raidexmibraidlisttable SYNTAX ACCESS STATUS DESCRIPTION ::={ raidexmibroot 5} OBJECT TYPE SEQUENCE OF raidexmibraidlistentry not-accessible mandatory "List of DKC which is registered on the SVP." raidexmibraidlistentry OBJECT TYPE SYNTAX RaidExMibRaidListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry of DKC list." INDEX { raidlistserialnumber } ::={ raidexmibraidlisttable 1} The following table lists the information displayed for each storage system Table 3-5 Storage system information Name Type Description Mounted value Attribute raidlistserialnumber ::=RaidExMibRaidListEntr y(1) INTEGER Storage system product number (index). 200, ,999 read-only raidlistmibnickname ::=RaidExMibRaidListEntr y(2) DisplaySt ring Storage system nickname. (Max. 18 characters) read-only 3 6 SNMP supported MIBs
31 Name Type Description Mounted value Attribute raidlistdkcmainversion ::=RaidExMibRaidListEntr y(3) raidlistdkcproductname ::=RaidExMibRaidListEntr y(4) raidexmibdkchwtable DisplaySt ring DisplaySt ring Microcode version. Max. 10 characters Storage system product type. 7 characters (1) read-only read-only Note: HM700 will be used as storage system product type raidlistdkcproductname. raidexmibdkchwtable indicates the status of the storage system components. raidexmibdkchwtable OBJECT TYPE SYNTAX SEQUENCE OF RaidExMibDKCHWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Error information of the DKC." ::={ raidexmibroot 6} raidexmibdkchwentry OBJECT TYPE SYNTAX RaidExMibDKCHWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry of DKC information." INDEX {dkcraidlistindexserialnumber} ::={ raidexmibdkchwtable 1} Table 3-6 Storage system component information Name Type Description MIB value Attribute dkcraidlistindexserialnu mber ::=raidexmibdkchwentr y(1) dkchwprocessor ::=raidexmibdkchwentr y(2) dkchwcsw ::=raidexmibdkchwentr y(3) dkchwcache ::=raidexmibdkchwentr y(4) dkchwsm ::=raidexmibdkchwentr y(5) INTEGER Storage system product number (index). 200, ,999 read-only INTEGER Status of processor. See Note read-only INTEGER Status of internal star. See Note read-only INTEGER Status of cache. See Note read-only INTEGER Status of shared memory. See Note read-only SNMP supported MIBs 3 7
32 dkchwps ::=raidexmibdkchwentr y(6) dkchwbattery ::=raidexmibdkchwentr y(7) dkchwfan ::=raidexmibdkchwentr y(8) dkchwenvironment ::=raidexmibdkchwentr y(9) raidexmibdkuhwtable Name Type Description MIB value Attribute INTEGER Status of power supply. See Note read-only INTEGER Status of battery. See Note read-only INTEGER Status of fan. See Note read-only INTEGER Information of an operational environment. See Note Note: The status of each component is a single digit which shows the following: 1: Normal. 2: Acute failure detected. 3: Serious failure detected. 4: Moderate failure detected. 5: Service failure detected. raidexmibdkuhwtable indicates the status of the storage system components. read-only raidexmibdkuhwtable OBJECT TYPE SYNTAX SEQUENCE OF RaidExMibDKUHWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Error information of the DKU." ::={ raidexmibroot 7} raidexmibdkuhwentry OBJECT TYPE SYNTAX RaidExMibDKUHWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry of DKU information." INDEX { dkuraidlistindexserialnumber } ::={ raidexmibdkuhwtable 1} Table 3-7 Disk device components information Name Type Description MIB value Attribut e dkuraidlistindexserialnum ber INTEGE R Storage system product number (index). 200, ,999 read-only ::=raidexmibdkuhwentry( 1) 3 8 SNMP supported MIBs
33 Name Type Description MIB value Attribut e dkuhwps ::=raidexmibdkuhwentry( 2) dkuhwfan ::=raidexmibdkuhwentry( 3) dkuhwenvironment ::=raidexmibdkuhwentry( 4) dkuhwdrive ::=raidexmibdkuhwentry( 5) raidexmibtraplisttable INTEGE R INTEGE R INTEGE R INTEGE R Status of power supply. See Note read-only Status of fan. See Note read-only Status of environment monitor. See Note raidexmibtraplisttable shows the history of the failure traps. read-only Status of drive. See Note read-only Note: The status of each component is a single digit which shows the following: 1: Normal. 2: Acute failure detected. 3: Serious failure detected. 4: Moderate failure detected. 5: Service failure detected. raidexmibtraplisttable OBJECT TYPE SYNTAX SEQUENCE OF RaidExMibTrapListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Trap list table." ::={ raidexmibroot 8 } raidexmibtraplistentry OBJECT TYPE SYNTAX RaidExMibTrapListEntry ACCESS non-accessible STATUS mandatory DESCRIPTION "Trap list table index." INDEX { eventlistindexserialnumber, eventlistindexrecordno } ::={ raidexmibtraplisttable 1 } Table 3-8 Failure information Name Type Description MIB value Attribute eventlistindexserialnu mber ::=raidexmibtrapliste ntry(1) INTEGER Storage system product number (index) 200, ,999 read-only SNMP supported MIBs 3 9
34 Name Type Description MIB value Attribute eventlistnickname ::=raidexmibtrapliste ntry (2) eventlistindexrecordn o ::=raidexmibtrapliste ntry (3) eventlistrefcode ::=raidexmibtrapliste ntry (4) eventlistdata ::=raidexmibtrapliste ntry (5) eventlisttime ::=raidexmibtrapliste ntry (6) eventlistdescription ::=raidexmibtrapliste ntry (7) DisplaySt ring Counter DisplaySt ring DisplaySt ring DisplaySt ring DisplaySt ring Storage system nickname Number of records 18 characters maximum read-only read-only Reference code 6 characters read-only Date when the failure was occurred Time when the failure occurred Detailed information about the failure yyyy/mm/dd (10 characters) hh:mm:ss (8 characters) 256 characters maximum read-only read-only read-only Extension MIB configuration Following figures show extension MIB configurations (1) and (2). Figure 3-4 Extension MIB configuration (1) 3 10 SNMP supported MIBs
35 Figure 3-5 Extension MIB configuration (2) SNMP supported MIBs 3 11
36 Figure 3-6 Extension MIB configuration (3) 3 12 SNMP supported MIBs
37 4 SNMP failure trap reference This topic shows the alert level, trap reference code, description, and alert level. SNMP failure trap reference codes SNMP failure trap reference 4 1
38 SNMP failure trap reference codes The following lists and describes the SNMP failure trap reference codes. Table 4-1 SNMP failure trap reference codes Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level x0 Ethernet error for SVP DKC MODERATE environment x0 Failure during SIM transfer to the SVP DKC SERIOUS environment Audit log disappeared DKC MODERATE environment System Disk not access Drive failure MODERATE xx Channel port block Processor MODERATE xx CHB Blocking Processor MODERATE xx DKB Blocking Processor MODERATE xy Logical paths on the remote copy connections was logically blocked (Due to an error conditions) Processor MODERATE xy The logical path has been recovered from blocked condition on the remote copy conditions Processor xy Link data transfer error Processor SERIOUS xy Link data transfer error Processor SERIOUS 21 D0 xy External storage system connection Processor MODERATE path blocking 21 D2 xy Threshold over by external storage system connection path response time-out Processor xy Processor blockade Processor MODERATE xy FM failure Processor MODERATE 30 A1 00 DKC blockade Processor Acute 39 A0 00 The upper temperature limit was exceeded 43 Bx xx Drive blockade (Media system) xxx: The drive number DKC environment Drive failure SERIOUS 43 Cy xx Drive blockade (Media system) Drive SERIOUS 45 1y xx Correction copy start Drive 45 2y xx Correction copy normal end Drive 45 3y xx Correction copy abnormal end Drive SERIOUS 45 5y xx Correction copy warning end Drive 46 1y xx Dynamic sparing start Drive 46 2y xx Dynamic sparing normal end Drive 4 2 SNMP failure trap reference
39 Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level 46 3y xx Dynamic sparing abnormal end Drive MODERATE 46 5y xx Dynamic sparing warning end Drive 47 Dx xx SI Copy abnormal end MODERATE 47 E7 00 Forcible suspend by SM volatile (SI) MODERATE 50 Bx yy Flash drive end of life Drive 50 Cx xx Flash module drive end of life Drive 62 0x xx The DP Pool Warning Threshold was exceeded Dynamic Provisioning Pool 62 2x xx DP Pool FULL Dynamic Provisioning Pool 62 3x xx DP Pool error is detected Dynamic Provisioning Pool No free area in SM Dynamic Provisioning Pool DP Pool threshold continues to be exceeded 62 6x xx The DP Pool Depletion threshold was exceeded Dynamic Provisioning Pool Dynamic Provisioning Pool 62 7x xx The DP Pool VOL blockade Dynamic Provisioning Pool DP Protect attribute setting of DRU Dynamic Provisioning Pool Acquisition failure of the outside encryption key Warning for depletion of cache management devices Encryption key Thin Image MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE MODERATE 7B ISDN Router failure SVP failure MODERATE 7C Audit log FTP transfer failed SVP failure MODERATE 7C Dump Tool failed SVP failure 7E 12 xx MP OPERATING RATIO ERROR Processor MODERATE 7F F4 xx Clean virus from file SVP failure 7F F5 xx Virus detected (Virus isolated) SVP failure MODERATE SNMP failure trap reference 4 3
40 Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level 7F F6 xx Virus detected (Virus isolation failed) SVP failure SERIOUS 7F F7 xx Expiration License key SERIOUS 7F F8 xx Exceeded the licensed capacity License key SERIOUS 7F F9 xx Program product invalidated by the expiration of the prerequisite program product License key SERIOUS 7F FA 00 Failure of adjusting the clock Adjusting the clock AC 50 xy HDU power supply shutdown PS (DB) MODERATE detected BF 1x 1x Abnormal temperature DKC MODERATE environment BF 4x 1x Warning for power supply PS (DKC) MODERATE BF 5x xx DBPS error PS (DB) MODERATE BF 6x xx DBPS AC input error PS (DB) MODERATE BF 7x xx Warning for fan Fan (DKC) MODERATE BF 85 A3 SVP RAS Switch#1 remains (SVP PS SVP failure MODERATE ON/OFF INH SW) BF D1 xx Battery charge EMPTY Battery MODERATE BF D4 xx CM Backup mounting warning Cache MODERATE CF 10 xx SAS controller blockade Processor MODERATE CF 12 xx SAS port blockade Processor MODERATE CF 6x xx Logical DMA blocking Processor MODERATE CF 82 xy DRR blockade Processor MODERATE CF 83 xy DMA blockade Processor MODERATE CF 88 xx MAIN Blade blocking Processor MODERATE CF 89 xx All DMA blockade Processor MODERATE D0 0x xx TC/HAM started the initial copy or out of sync for this volume D0 1x xx TC/HAM completed the initial copy for this volume D0 2x xx TC/HAM for this volume was deleted (Operation from an SVP/Web Console or a host processor) D0 6x xx Completed the Create pair (No copy suspend) D1 0x xx Status of the R-VOL is changed. (*)From Simplex to Duplex Pending 4 4 SNMP failure trap reference
41 Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level D1 1x xx Status of the R-VOL is changed. (*)From Simplex to Duplex D1 2x xx Status of the R-VOL is changed. (*)From Duplex Pending to Duplex D1 3x xx Status of the R-VOL is changed. (*)From Duplex Pending to Suspend D1 4x xx Status of the R-VOL is changed. (*)From Duplex to Suspend D1 5x xx Status of the R-VOL is changed. (*)From Duplex to Simplex D1 6x xx Status of the R-VOL is changed. (*)From Duplex Pending to Simplex D1 7x xx Status of the R-VOL is changed. (*)From Suspend to Simplex D1 8x xx Status of the R-VOL is changed. (*)From Suspend to Duplex Pending D1 9x xx Status of the R-VOL is changed. (*)From Duplex Pending to Suspend (continue) D1 Ax xx Status of the R-VOL is changed. (*)From Duplex Pending to Suspend (complete) D1 Bx xx Status of the R-VOL is changed. (*)From Suspend (continue) to Suspend D1 Cx xx Status of the R-VOL is changed. (*)From Simplex to Suspend D4 0x xx TC/HAM for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) D4 1x xx TC/HAM for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) D4 2x xx TC/HAM for this volume was suspended (Due to an unrecoverable failure on the R-VOL) SERIOUS SERIOUS SERIOUS SNMP failure trap reference 4 5
42 Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level D4 3x xx This volume was suspended (Caused by DFW to the R-VOL was prohibited) D4 4x xx TC/HAM for this volume was suspended (Due to an internal error condition detected by the RCU) D4 5x xx TC/HAM for this volume was suspended (Caused by Delete pair operation was issued to the R-VOL) D4 Fx xx Status of the M-VOL was not consistent with the R-VOL D8 0x xx A volume to be used by the UR was defined D8 1x xx The volume being used by the UR began a copying D8 2x xx The volume being used by the UR completed a copying D8 3x xx The volume being used by the UR received a request for suspension D8 4x xx The volume being used by the UR completed a suspension transaction D8 5x xx The volume being used by the UR received a request for deletion D8 6x xx The volume being used by the UR completed the deletion D8 7x xx The volume being used by the UR was defined (placed in the PSUS status immediately) D8 8x xx A Delta volume to be used by the UR was defined D8 9x xx A Delta volume to be used by the UR was redefine D9 0x xx A change to an S-VOL was received from the MCU. (*)From Simplex to Duplex Pending SERIOUS SERIOUS SERIOUS SERIOUS 4 6 SNMP failure trap reference
43 Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level D9 1x xx A change to an S-VOL was received from the MCU. (*)From Simplex to Duplex D9 2x xx A change to an S-VOL was received from the MCU. (*)From Duplex Pending to Duplex D9 3x xx A change to an S-VOL was received from the MCU. (*)From Duplex Pending to Suspend D9 4x xx A change to an S-VOL was received from the MCU. (*)From Duplex to Suspend D9 5x xx A change to an S-VOL was received from the MCU. (*)From Duplex to Simplex D9 6x xx A change to an S-VOL was received from the MCU. (*)From Duplex Pending to Simplex D9 7x xx A change to an S-VOL was received from the MCU. (*)From Suspend to Simplex D9 8x xx A change to an S-VOL was received from the MCU. (*)From Suspend to Duplex Pending D9 9x xx A change to an S-VOL was received from the MCU. (*)From Hold to Duplex D9 Ax xx A change to an S-VOL was received from the MCU. (*)From Hold to Duplex Pending D9 Cx xx A change to an S-VOL was received from the MCU. (*)From Simplex to Suspend D9 Dx xx A change to an S-VOL was received from the MCU. (*)From Simplex to Hold D9 Ex xx A change to an S-VOL was received from the MCU. (*)From Suspend to Hold D9 Fx xx A change to an S-VOL was received from the MCU. (*)From Duplex to Duplex Pending DC 0x xx Volume used as P-VOL has been suspended (Unable to restore path) SERIOUS SNMP failure trap reference 4 7
44 Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level DC 1x xx Volume used as P-VOL has been suspended (MCU failure detected) DC 2x xx A volume being used by a P-VOL was suspended (Suspension of an S-VOL failure was detected) DC 4x xx Volume used as P-VOL has been suspended (S-VOL suspension detected) DC 5x xx Volume used as P-VOL has been suspended (S-VOL pair deletion detected) DC 6x xx Volume used as S-VOL has been suspended (Unable to restore path) DC 7x xx Volume used as S-VOL has been suspended (RCU failure detected) DC 9x yy Volume used as a P-VOL of Delta resync has been suspended x: The CU number yy: The LDEV number DC Ax yy Pair suspend (Spread by error of another Affiliate) SERIOUS SERIOUS SERIOUS SERIOUS SERIOUS SERIOUS SERIOUS SERIOUS DF 8y xx Drive port blockade (Path 0 side) Drive MODERATE DF 9y xx Drive port blockade (Path 1 side) Drive MODERATE DF Ay xx LDEV blockade (Drive path: Boundary 0/ Effect of Drive port blockade) Drive SERIOUS DF By xx LDEV blockade (Drive path: Boundary 1/ Effect of Drive port blockade) Drive SERIOUS EF 0x xx Drive blockade (drive) (with Drive failure SERIOUS redundancy) EF 1y xx Drive blockade (drive) (without Drive SERIOUS redundancy) EF 2x xx Drive blockade (Effect of Dynamic Drive sparing normal end) EF 9y xx LDEV blockade (Effect of drive Drive SERIOUS blockade) EF D0 00 Device connecting to external Drive SERIOUS storage system is blocked EF FE xx UNIT connection cable order error Processor MODERATE 4 8 SNMP failure trap reference
45 Trap reference code SIM 22 SIM 23 SIM 13 Description Alert level FF C2 xy Cache Module Blockade processing Cache finished FF C3 0x REAL MEMORY SIZE INCONSISTENT Cache FF E2 0x Area blocking SM SERIOUS FF E7 xx Rebooted with volatilization after an SM SERIOUS instantaneous down FF EA 0x Recovery of area blocked temporarily SM was completed FF EE 0x Temporary blockade SM FF F1 xy Cache temporary failure Cache FF F2 xy Module group blocking Cache MODERATE FF F3 0x Package blockade Cache MODERATE FF F4 0x Module group blocking Cache SERIOUS Others Other failures Other failures SERIOUS SNMP failure trap reference 4 9
46 4 10 SNMP failure trap reference
47 5 Troubleshooting This topic provides troubleshooting information for the Hitachi SNMP Agent. Getting help Solving SNMP problems Troubleshooting 5 1
48 Getting help If you have difficulty with any of the procedures included in this topic, or if a procedure does not provide the answer or results you expect, please contact Hitachi Data Systems Support Center. See Getting help on page Preface-viii in the Preface for information about accessing the support portal. Solving SNMP problems Use setup.exe when you install a secondary SVP. If you do not, traps could be reported to an IP address that is not specified in SNMP settings. This could have serious consequences, including the following: SNMP security function If the SNMP security function is working, and a command is executed from an IP address that is not entered, you will get a no reply return and a certification error is received for a trap. SNMP cold trap function Depending on your network environment, when the SVP is rebooted you might not receive Microsoft agent SNMP Agent cold traps. The Microsoft SNMP Agent might report Link up/link down Trap when the SVP reboots. A number of Link up/link down Traps may be reported when the OS of the SVP is Windows Vista. Abnormal response to SNMP command If an error occurs in the SVP, traps might not be sent. Problems inputting MIB definition files If you cannot input two or more MIB definition files because of the specifications of the SNMP manager software, use the MIB definition files for HUS VM. Error reports include storage system nicknames, which can be used to identify each storage system. 5 2 Troubleshooting
49 A SNMP GUI reference This appendix describes the procedures to use the SNMP Information window. SNMP Information window SNMP GUI reference A 1
50 SNMP Information window 1. Launch Storage Navigator and log in. 2. In the Storage Navigator main window, click Settings > Environmental Setting > SNMP Information in the menu bar. The SNMP Information window is displayed. 3. In the SNMP Information window, click SNMP Information. The following table describes the items that are displayed. Table A-1 SNMP Information window Item Install Manager IP Address Description The Extension SNMP check-box is selected if the SNMP Agent feature is enabled. To set the SNMP Agent properties from the Storage Navigator console, select Extension SNMP in the SNMP Information window. The Manager section allows you to add and delete SNMP Manager information. Displays the IP addresses of registered SNMP managers from which the SNMP Agent accepts requests. If no manager is registered, the SNMP Agent accepts requests from all managers. You can register up to 32 managers. A 2 SNMP GUI reference
51 IP Address IPv4 IPv6 Item Set Community & Trap Description Enter the IP address of the manager that the SNMP Agent receives the request from. IPv4 and IPv6 addresses can be specified for IP Address. However, if the OS of the SVP is Windows XP and you enter the IPv6 address and select Apply, an error message is displayed and the IPv6 address is not set. Any IP address having all values set to zero (0) cannot be specified for IPv4 and IPv6. The IPv4 address is specified by entering four numbers that are separated by periods (.) using a maximum of three digits from zero (0) to 255 inclusive. (For example: XXX.XXX.XXX.XXX when X is a number). Enter the numbers only and do not enter periods. The IPv6 address is specified by entering eight hexadecimal numbers that are separated by colons (:) using a maximum of 4 digits from zero (0) to FFFF inclusive. (For example: YYYY:YYYY:YYYY:YYYY:YYYY:YYYY:YYYY:YYYY when Y is a hexadecimal number). Enter the hexadecimal numbers only, and do not enter the colons. The cursor can be moved between the entry fields using the Tab key. Is selected when entering an IPv4 address. The IPv4 address can be entered in the IP address text box when this button is selected. Is selected when entering an IPv6 address. The IPv6 address can be entered in the IP address text box when this button is selected. Adds new IP addresses to the IP Address list box. Allows you to add, delete, or change SNMP trap information. The registered IP address is the trap destination for the specified community. Each community can have more than one defined IP address (see Adding a community name on page 2-4 and Adding a community IP address on page 2-7). You can register up to 32 community names and up to 32 IP addresses per community name. You can use up to 180 alphanumeric characters in a community name. You cannot use the following special characters: ", \, ;, :,,, *,?, <, >,, /, ^, &, and %. SNMP GUI reference A 3
52 Item System Group Trap Test Apply Cancel Description Allows you to add, delete or change SNMP system group information. If system group information has already been registered, the registered information displays. To register the system group information, the Extension SNMP check-box must be selected. To register system group information, click Apply. System group information includes the following items: Name: This is the name of the connected storage system device. Storage Navigator users can change the device name. The name can include up to 180 alphanumeric characters, but cannot include the following special characters: ", \, ;, :,,, *,?, <, >,, /, ^, &, and %. The device name is required to use SNMP Agent. Make sure to document the device name, because settings will be cleared when the SVP is replaced. Contact: Contact information such as personnel and telephone numbers where you can inquire about the connected storage system. Storage Navigator users can change contact information in the Modify mode. contact information using up to 180 alphanumeric characters (ASCII codes), except for some symbols, such as ", \, ;, :,,, *,?, <, >,, /, ^, &, and %. A contact name is required to use SNMP Agent. Make sure to document the contact name, because settings will be cleared when the SVP is replaced. Location: Location of connected storage system. Storage Navigator users can change device locations with the modify mode. You must enter a device location using up to 180 alphanumeric characters (ASCII codes). You cannot use some symbols, such as ", \, ;, :,,, *,?, <, >,, /, ^, &, and %. The device location is required to use SNMP Agent. Make sure to document the device location, because the settings will be cleared when SVP is replaced. Executes test report of the trap to the community registered in the Unified Storage VM storage system. You must be in Modify mode to use this button. You must have Storage Administrator privileges. Implements settings made on this window. You must be in Modify mode to use this button. You must have Storage Administrator privileges. Cancels settings made on this window. A 4 SNMP GUI reference
53 Glossary This glossary defines the special terms used in this document. Click the letter links below to navigate. C Community Name E An SNMP entity in which up to 32 names and up to 32 IP addresses can be registered. Extension Trap F An error message generated by a third-party node and sent to the SNMP agent. Failure Trap I IPv4 IPv6 An error message that indicates a problem within a managed node. Internet Protocol version 4 Internet Protocol version 6 # A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Glossary 1
54 M Managed Device MIB P PDU S A network node on which the SNMP agent software is installed. Using the agent, managed devices exchange node-specific information with the SNMP management software. Management Information Base - a standardized configuration and database of network management information. It is common to all SNMP interfaces SGMP SNMP power distribution unit; protocol data unit simple gateway management protocol Simple Network Management Protocol - an industry-standard protocol that is used to manage and monitor network-attached devices for conditions that warrant administrative attention. The devices can include disk devices, routers, and hubs. SNMP uses Simple Gateway Management Protocol (SGMP) to manage TCP/IP gateways. SNMP Agent Software that is installed on the SVP and responds to queries from the SNMP manager. SNMP Manager Software that It is installed on the computer where Storage Navigator is installed. SNMP Trap An error message generated by a node and sent to the SNMP agent. The SNMP agent passes the message to the SNMP manager. # A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Glossary 2
55 U UDP user datagram protocol - software that requests data regarding the status of a managed node. # A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Glossary 3
56 # A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Glossary 4
57 Index A adding community names 2 4, 2 7 SNMP Manager IP addresses 2 2 architecture, SNMP environment 1 3 C changing community names 2 6 cold trap function, troubleshooting 5 2 community names adding 2 4, 2 7 changing 2 6 deleting 2 5 components, storage system 1 6 configuration, SNMP Agent 1 3 D definition files, trouble inputting 5 2 deleting community names 2 5 SNMP Manager IP addresses 2 3 E environment architecture, SNMP 1 3 errors REQUEST operation 1 5 SNMP Agent 1 5 extension configuration, MIB 3 10 extension trap protocol data unit (PDU) 3 2 types 3 2 F failure report 3 2 trap reference codes 4 2 functions, SNMP Agent 1 4 H help 5 2 I interaction, SNMP Manger and SNMP Agent 1 2 M Management Information Base (MIB) 1 3 MIB access mode 3 3 extension configuration 3 10 extension specifications 3 5 mounting specifications 3 4 object identifier system 3 3 specifications 3 3 supported 3 3 MIB definition files, trouble inputting 5 2 mounting MIB specifications 3 4 system groups 3 4 O operations, SNMP Agent 1 5 overview 1 2 P protocol data unit (PDU) 3 2 R raidexmibagentversion 3 5 raidexmibdkccount 3 6 raidexmibdkchw 3 7 raidexmibdkuhw 3 8 raidexmibname 3 5 raidexmibraidlist 3 6 raidexmibtraplist 3 9 raidexmibversion 3 5 S security function, troubleshooting 5 2 Simple Network Management Protocol (SNMP) 1 2 SNMP Agent Index 1
58 configuration 1 3 errors 1 5 functions 1 4 operations 1 5 traps 1 4 SNMP environment architecture 1 3 SNMP failure, trap reference codes 4 2 SNMP Manager component status 1 6 overview 1 2 SNMP Manager IP addresses adding 2 2 deleting 2 3 specifications MIB mounting 3 4 status, storage system components 1 6 system groups, mounting 3 4 T traps failure reference codes 4 2 failure report 3 2 SNMP Agent 1 4 supported types 3 2 triggers 1 4 troubleshooting abnormal response to SNMP commands 5 2 inputting MIB definition files 5 2 SNMP cold trap function 5 2 SNMP security function 5 2 Index 2
59
60 Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California U.S.A. Regional Contact Information Americas Europe, Middle East, and Africa +44 (0) Asia Pacific MK-92HM
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Hitachi SNMP Agent User Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7025-09 2010-2013 Hitachi Ltd. All rights reserved. No part
Hitachi Virtual Storage Platform G1000
Hitachi Virtual Storage Platform G1000 Hitachi SNMP Agent User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92RD8015-02 2014 Hitachi, Ltd. All rights reserved. No part of this publication
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Data Retention Utility User s Guide
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Data Retention Utility User s Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD612-03
Hitachi Unified Storage VM Block Module
Hitachi Unified Storage VM Block Module Hitachi Universal Replicator User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92HM7019-08 2012-2014 Hitachi, Ltd. All rights reserved. No part
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Hitachi Universal Replicator User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7032-14 2010-2014 Hitachi, Ltd. All rights reserved. No part of this
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Encryption License Key User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7015-10 2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication
Hitachi Virtual Storage Platform G1000
Hitachi Virtual Storage Platform G1000 Encryption License Key User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92RD8009-02 2014 Hitachi, Ltd. All rights reserved. No part of this publication
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Dynamic Provisioning User s Guide
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Dynamic Provisioning User s Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD641-07 Copyright
Tuning Manager. Hitachi Command Suite. Server Administration Guide MK-92HC021-38. FASTFIND LINKS Document Organization. Product Version.
Hitachi Command Suite Tuning Manager Server Administration Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-92HC021-38 2015 Hitachi, Ltd. All rights reserved. No part
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Performance Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7020-12 2010-2013 Hitachi Ltd. All rights reserved. No part of this
Hitachi Compute Blade 500 Series NVIDIA GPU Adapter User s Guide
Hitachi Compute Blade 500 Series NVIDIA GPU Adapter User s Guide FASTFIND LINKS Getting Help Contents MK-91CB500083-01 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced
Hitachi Unified Storage VM Block Module
Hitachi Unified Storage VM Block Module System Operations Using Spreadsheets FASTFIND LINKS Contents Product Version Getting Help MK-92HM7015-02 2012-2013 Hitachi Ltd. All rights reserved. No part of this
Hitachi NAS Blade for TagmaStore Universal Storage Platform and Network Storage Controller NAS Blade Error Codes User s Guide
Hitachi NAS Blade for TagmaStore Universal Storage Platform and Network Storage Controller NAS Blade Error Codes User s Guide MK-95RD280-03 2006 Hitachi, Ltd., Hitachi Data Systems Corporation, ALL RIGHTS
Configuration Guide for VMware ESX Server Host Attachment
Configuration Guide for VMware ESX Server Host Attachment Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM Hitachi TagmaStore Universal Storage Platform
Hitachi Device Manager Software Getting Started Guide
Hitachi Device Manager Software Getting Started Guide FASTFIND LINKS Document Organization Software Version Getting Help Contents MK-98HC149-03 Copyright 2008, 2009 Hitachi Ltd., Hitachi Data Systems Corporation,
FASTFIND LINKS. Document Organization Product Version Getting Help Contents MK-96RD617-06
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Performance Manager User s Guide Performance Monitor, Volume Migration, and Server Priority Manager FASTFIND LINKS Document
Hitachi Data Ingestor
Hitachi Data Ingestor Backup Restore Features Supplement for Hitachi Data Protection Suite Product Version Getting Help Contents MK-90HDI009-14 2010-2015 Hitachi, Ltd. All rights reserved. No part of this
Compute Systems Manager
Hitachi Command Suite Compute Systems Manager Installation and Configuration Guide MK-91HC195-12 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted
FASTFIND LINKS. Document Organization. Product Version. Getting Help. Contents MK-96RD617-15
Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Performance Manager User s Guide Performance Monitor and Server Priority Manager FASTFIND LINKS Document Organization
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Hitachi Storage Navigator User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7027-15 2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication
Silect Software s MP Author
Silect MP Author for Microsoft System Center Operations Manager Silect Software s MP Author User Guide September 2, 2015 Disclaimer The information in this document is furnished for informational use only,
SNMP Agent Plug-In Help. 2011 Kepware Technologies
2011 Kepware Technologies 2 Table of Contents Table of Contents 2 4 Overview 4 Agent Setup 5 General 6 Network Interfaces 6 Communication 7 Agent Actions 9 System Objects 10 System Objects Description
Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.
ServerView User s Guide (For Windows Agent) Areas Covered - Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of ServerView
Hitachi Application Protector User Guide for Microsoft SQL Server
Hitachi Application Protector User Guide for Microsoft SQL Server FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-91HAP007-06 Copyright 2011-2014 Hitachi, Ltd., Hitachi Data
System and Network Management
- System and Network Management Network Management : ability to monitor, control and plan the resources and components of computer system and networks network management is a problem created by computer!
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
Remote Management. Vyatta System. REFERENCE GUIDE SSH Telnet Web GUI Access SNMP VYATTA, INC.
VYATTA, INC. Vyatta System Remote Management REFERENCE GUIDE SSH Telnet Web GUI Access SNMP Vyatta Suite 200 1301 Shoreway Road Belmont, CA 94002 vyatta.com 650 413 7200 1 888 VYATTA 1 (US and Canada)
NETWORK PRINT MONITOR User Guide
NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
Compute Systems Manager
Hitachi Command Suite Compute Systems Manager User Guide MK-91HC194-10 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,
HP IMC User Behavior Auditor
HP IMC User Behavior Auditor Administrator Guide Abstract This guide describes the User Behavior Auditor (UBA), an add-on service module of the HP Intelligent Management Center. UBA is designed for IMC
Job Management Partner 1/File Transmission Server/FTP Description, Reference and Operator's Guide
For Windows Systems Job Management Partner 1 Version 10 Job Management Partner 1/File Transmission Server/FTP Description, Reference and Operator's Guide 3021-3-334-10(E) Notices Relevant program products
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
Server Installation Guide ZENworks Patch Management 6.4 SP2
Server Installation Guide ZENworks Patch Management 6.4 SP2 02_016N 6.4SP2 Server Installation Guide - 2 - Notices Version Information ZENworks Patch Management Server Installation Guide - ZENworks Patch
Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
System i and System p. Customer service, support, and troubleshooting
System i and System p Customer service, support, and troubleshooting System i and System p Customer service, support, and troubleshooting Note Before using this information and the product it supports,
Configuration Guide for Microsoft Windows Host Attachment
Configuration Guide for Microsoft Windows Host Attachment Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Contents Product Version Getting
TIBCO Hawk SNMP Adapter Installation
TIBCO Hawk SNMP Adapter Installation Software Release 4.9.0 November 2012 Two-Second Advantage Important Information SOME TIBCO SOFTWARE EMBEDS OR BUNDLES OTHER TIBCO SOFTWARE. USE OF SUCH EMBEDDED OR
HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide
HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide Abstract This guide describes the Virtualization Monitor (vmon), an add-on service module of the HP Intelligent Management
MULTIFUNCTIONAL DIGITAL SYSTEMS. TopAccess Guide
MULTIFUNCTIONAL DIGITAL SYSTEMS TopAccess Guide 0 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without prior written permission of
Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13
Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13 The information contained in this guide is not of a contractual nature and may be subject to change without prior notice. The software described in this
USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. www.pesa.com August 2014 Phone: 256.726.9200. Publication: 81-9059-0703-0, Rev. C
USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION Publication: 81-9059-0703-0, Rev. C www.pesa.com Phone: 256.726.9200 Thank You for Choosing PESA!! We appreciate your confidence in our products. PESA produces
PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -
Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors
WhatsUp Gold v16.2 Installation and Configuration Guide
WhatsUp Gold v16.2 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.2 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines
Configuring and Monitoring Hitachi SAN Servers
Configuring and Monitoring Hitachi SAN Servers eg Enterprise v5.6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this
Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference
Job Management Partner 1 Version 10 Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference 3021-3-353(E) Relevant program products
MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator s Manual for Backup/Restore Utility
MULTIFUNCTIONAL DIGITAL SYSTEMS Operator s Manual for Backup/Restore Utility 2009 KYOCERA MITA Corporation All rights reserved Preface Thank you for purchasing Multifunctional Digital Color Systems. Read
Administrator s Guide
Administrator s Guide Citrix Network Manager for MetaFrame XPe Version 1.0 Citrix Systems, Inc. Information in this document is subject to change without notice. Companies, names, and data used in examples
FASTFIND LINKS. Contents Product Version Getting Help MK-96RD640-05
Configuration Guide for Red Hat Linux Host Attachment Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Contents Product Version Getting
How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7
Contents Introduction--1 Product definition 1 Implementing SNMP 2 Integrating SNMP into the user interface 3 Components of OPC SNMP Gateway 4 How to Obtain an OPC License--5 Creating a System Code 5 Entering
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide 7-2006 ONL-4152aN-COMMON-128-99-0606 PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs
Know the signs of potential problems. Prevent problems before they occur. This unit contains the following three lessons:
Unit 6 Router Management Overview Description With today s networks growing exponentially, management is a key to quality of network performance. People depend on their networks and performance issues
Hitachi Storage Replication Adapter 2.1 for VMware vcenter Site Recovery Manager 5.1/5.5 Deployment Guide
Hitachi Storage Replication Adapter 2.1 for VMware vcenter Site Recovery Manager 5.1/5.5 Deployment FASTFIND LINKS Document conventions Product version Getting help Contents MK-09RM6745-08 2009-2014 Hitachi
Accounting Manager. User Guide A31003-P1030-U114-2-7619
Accounting Manager User Guide A31003-P1030-U114-2-7619 Our Quality and Environmental Management Systems are implemented according to the requirements of the ISO9001 and ISO14001 standards and are certified
Core Protection for Virtual Machines 1
Core Protection for Virtual Machines 1 Comprehensive Threat Protection for Virtual Environments. Installation Guide e Endpoint Security Trend Micro Incorporated reserves the right to make changes to this
Table of Contents. Overview...2. System Requirements...3. Hardware...3. Software...3. Loading and Unloading MIB's...3. Settings...
Table of Contents Overview...2 System Requirements...3 Hardware...3 Software...3 Loading and Unloading MIB's...3 Settings...3 SNMP Operations...4 Multi-Varbind Request...5 Trap Browser...6 Trap Parser...6
Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual
Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual www.hillstonenet.com Preface Conventions Content This document follows the conventions below: CLI Tip: provides
Features Overview Guide About new features in WhatsUp Gold v14
Features Overview Guide About new features in WhatsUp Gold v14 Contents New Features in Ipswitch WhatsUp Gold v14 Welcome to WhatsUp Gold v14!... 1 About the Welcome Center About the Quick Setup Assistant...
SNMP. Overview. LabTech
SNMP SNMP 1 Overview... 1 SNMP Versions... 1 Understanding MIBs... 2 MIB Object Definitions... 3 SNMP Walking... 3 SNMP Traps... 4 Adding Trap Filters... 4 Sample Trap Creation... 7 SNMP Traps Received...
Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform
1 Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform Implementation Guide By Sean Siegmund June 2011 Feedback Hitachi Data Systems welcomes your feedback.
How To Create An Easybelle History Database On A Microsoft Powerbook 2.5.2 (Windows)
Introduction EASYLABEL 6 has several new features for saving the history of label formats. This history can include information about when label formats were edited and printed. In order to save this history,
Avalanche Site Edition
Avalanche Site Edition Version 4.8 avse ug 48 20090325 Revised 03/20/2009 ii Copyright 2008 by Wavelink Corporation All rights reserved. Wavelink Corporation 6985 South Union Park Avenue, Suite 335 Midvale,
Software License Registration Guide
Software License Registration Guide When you have purchased new software Chapter 2 Authenticating a License When you would like to use the software on a different PC Chapter 3 Transferring a License to
HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide
HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant PRO Management Pack for Microsoft System Center version
How To Use An Ec Esmpro Agent On A Pc Or Mac Or Ipad (Windows) With A Microsoft Powerbook (Windows 3) With An Ec Ecpro Agent (Windows 2) On A Network (Windows 4) With The
NEC Express5800 Series NEC ESMPRO Agent User's Guide 12-2006 ONL-4156aN-COMMON-126-99-0612 PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
There are numerous ways to access monitors:
Remote Monitors REMOTE MONITORS... 1 Overview... 1 Accessing Monitors... 1 Creating Monitors... 2 Monitor Wizard Options... 11 Editing the Monitor Configuration... 14 Status... 15 Location... 17 Alerting...
Installing, Uninstalling, and Upgrading Service Monitor
CHAPTER 2 Installing, Uninstalling, and Upgrading Service Monitor This section contains the following topics: Preparing to Install Service Monitor, page 2-1 Installing Cisco Unified Service Monitor, page
Personal Call Manager User Guide. BCM Business Communications Manager
Personal Call Manager User Guide BCM Business Communications Manager Document Status: Standard Document Version: 04.01 Document Number: NN40010-104 Date: August 2008 Copyright Nortel Networks 2005 2008
UNICORN 7.0. Administration and Technical Manual
UNICORN 7.0 Administration and Technical Manual Page intentionally left blank Table of Contents Table of Contents 1 Introduction... 1.1 Administrator functions overview... 1.2 Network terms and concepts...
Hitachi Virtual Storage Platform
Hitachi Virtual Storage Platform Hitachi Storage Navigator User Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7027-11 2010-2013 Hitachi Ltd, All rights reserved.
OfficeServ Link. User Guide. Version 2.1 June 2005
OfficeServ Link User Guide Version 2.1 June 2005 OfficeServ Link Version 2.1 User Guide This manual should be read before the installation and operation of the OfficeServ Link Software. COPYRIGHT This
Database Administration
Unified CCE, page 1 Historical Data, page 2 Tool, page 3 Database Sizing Estimator Tool, page 11 Administration & Data Server with Historical Data Server Setup, page 14 Database Size Monitoring, page 15
Hitachi Command Suite. Tuning Manager. Installation Guide. Document Organization. Product Version. Getting Help. Contents MK-96HC141-27
Hitachi Command Suite Tuning Manager Installation Guide Document Organization Product Version Getting Help Contents MK-96HC141-27 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication
UNICORN 6.4. Administration and Technical Manual
UNICORN 6.4 Administration and Technical Manual Page intentionally left blank Table of Contents Table of Contents 1 Introduction... 1.1 Administrator functions overview... 1.2 Network terms and concepts...
Hitachi File Services Manager 5.2.1-00 Release Notes
Hitachi File Services Manager 5.2.1-00 Release Notes Copyright 2011, 2015, Hitachi, Ltd., Hitachi Data Systems Corporation, ALL RIGHTS RESERVED Notice: No part of this publication may be reproduced or
Avaya Wireless AP Device Manager User Guide
Avaya Wireless AP Device Manager User Guide February 2003 Avaya Wireless AP Device Manager User Guide Copyright Avaya Inc. 2003 ALL RIGHTS RESERVED The products, specifications, and other technical information
VMware/Hyper-V Backup Plug-in User Guide
VMware/Hyper-V Backup Plug-in User Guide COPYRIGHT No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying,
ITEC310 Computer Networks II
ITEC310 Computer Networks II Chapter 28 Network Management: Department of Information Technology Eastern Mediterranean University Objectives 2/60 After completing this chapter you should be able to do
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
EMC NetWorker Module for Microsoft Exchange Server Release 5.1
EMC NetWorker Module for Microsoft Exchange Server Release 5.1 Installation Guide P/N 300-004-750 REV A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
WhatsUp Gold v16.1 Installation and Configuration Guide
WhatsUp Gold v16.1 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.1 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines
IBM i Version 7.2. Security Service Tools
IBM i Version 7.2 Security Service Tools IBM i Version 7.2 Security Service Tools Note Before using this information and the product it supports, read the information in Notices on page 37. This edition
Backup Server DOC-OEMSPP-S/6-BUS-EN-21062011
Backup Server DOC-OEMSPP-S/6-BUS-EN-21062011 The information contained in this guide is not of a contractual nature and may be subject to change without prior notice. The software described in this guide
Hitachi Command Suite. Automation Director. Installation and Configuration Guide MK-92HC204-00
Hitachi Command Suite Automation Director Installation and Configuration Guide MK-92HC204-00 2015 Hitachi, Ltd. All rights reserved No part of this publication may be reproduced or transmitted in any form
Troubleshooting. System History Log. System History Log Overview CHAPTER
CHAPTER 10 This section provides you will tools to help you to troubleshoot the Cisco Intercompany Media Engine server. For more information on troubleshooting the Cisco Intercompany Media Engine feature,
QUANTIFY INSTALLATION GUIDE
QUANTIFY INSTALLATION GUIDE Thank you for putting your trust in Avontus! This guide reviews the process of installing Quantify software. For Quantify system requirement information, please refer to the
Remote Access Server - Dial-Out User s Guide
Remote Access Server - Dial-Out User s Guide 95-2345-05 Copyrights IBM is the registered trademark of International Business Machines Corporation. Microsoft, MS-DOS and Windows are registered trademarks
Gigabyte Content Management System Console User s Guide. Version: 0.1
Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...
Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature
Table of Content Error Messages List... 2 Troubleshooting the Storage System... 3 I can t access the Manager... 3 I forgot the password for logging in to the Manager... 3 The users can t access the shared
Network Monitoring with SNMP
Network Monitoring with SNMP This paper describes how SNMP is used in WhatsUp- Professional and provides specific examples on how to configure performance, active, and passive monitors. Introduction SNMP
ScriptLogic Enterprise Security Reporter. VERSION 3 Installation Guide
ScriptLogic Enterprise Security Reporter VERSION 3 Installation Guide ENTERPRISE SECURITY REPORTER 3 INSTALLATION GUIDE II Copyright 2011 by ScriptLogic Corporation All rights reserved. This publication
GlobalSCAPE DMZ Gateway, v1. User Guide
GlobalSCAPE DMZ Gateway, v1 User Guide GlobalSCAPE, Inc. (GSB) Address: 4500 Lockhill-Selma Road, Suite 150 San Antonio, TX (USA) 78249 Sales: (210) 308-8267 Sales (Toll Free): (800) 290-5054 Technical
Pre-Installation Checks Installation Creating Users and Quick Setup Usage Examples and Settings Appendix
Standard Setup Guide 1 2 3 4 5 Pre-Installation Checks Installation Creating Users and Quick Setup Usage Examples and Settings Appendix Read this manual carefully before you use this product and keep it
GLBP - Gateway Load Balancing Protocol
GLBP - Gateway Load Balancing Protocol Gateway Load Balancing Protocol (GLBP) protects data traffic from a failed router or circuit, like Hot Standby Router Protocol (HSRP) and Virtual Router Redundancy
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 User Guide P/N 300-999-671 REV 02 Copyright 2007-2013 EMC Corporation. All rights reserved. Published in the USA.
System Center Configuration Manager 2007
System Center Configuration Manager 2007 Software Distribution Guide Friday, 26 February 2010 Version 1.0.0.0 Baseline Prepared by Microsoft Copyright This document and/or software ( this Content ) has
StruxureWare Power Monitoring 7.0.1
StruxureWare Power Monitoring 7.0.1 Installation Guide 7EN02-0308-01 07/2012 Contents Safety information 5 Introduction 7 Summary of topics in this guide 7 Supported operating systems and SQL Server editions
HP Data Protector Integration with Autonomy LiveVault
HP Data Protector Integration with Autonomy LiveVault Introducing cloud backup for HP Data Protector environments Technical white paper Table of contents Summary... 2 Introduction... 2 Integration concepts...
TANDBERG MANAGEMENT SUITE 10.0
TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS
Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device
Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device SNMPc supports many devices straight out of the box. Its generic support for device classes such as Switches, Routers and Servers
