GB/US... GH3/GH3+ Ceiling Hoist
|
|
|
- Baldric Greene
- 9 years ago
- Views:
Transcription
1 GB/US GH3/GH3+ Ceiling Hoist Vers W1
2
3 GH3 Lifting modules, version type nomenclature Guldmann hoist type Product line Load in kg Number of lifting straps Number of lifting motors Number of horizontal drive motors Scale module CLM module Service module User interface GH3 (x) xxx x x x x x x x GH None : 0 Scale : Twin None : 0 CLM : 1 Config : 2 None : 0 Service: 1 Config : 2 Hand control: 0 IR : 1 GH3 X Y Z Z Z Q Q Q Q 3
4 GH3/GH3+ Ceiling Hoist Item nos: 552xxx 100 Purpose and use Manufacturer Purpose Important/Precautions Load limits on GH3 system Unpacking and Preparation Placing a new Hoist in an existing rail system Power supply Installation of the lifting hanger before use Lifting sling Swing kit 12 1 Using swing kit in doorway GH3 with horizontal drive motor GH3 with horizontal drive motor and infrared remote (IR) control Description of functions Pictograms Indicator lamps and audio signals Operation Supplementary modules, GH3+ 18 Menu structure, Supplementary modules GH Configuration of supplementary modules, GH Scale module (GH3+ with integrated scale module) CLM module (GH3+ with statistical function for management use) Service module (GH3+ with service module) Safety functions Charging/connection Accessories Transport and storage Maintenance and storage Cleaning Storage How to prevent/avoid corrosion? The owner s daily maintenance duty Disposal of the GH3 including batteries Service and lifetime Lifetime Safety/service inspections Troubleshooting 33
5 600 Classification Certificates Technical specifications EC-Declaration of conformity 39 USA and countries outside the EU 40 A Users guide 40 B Warranties 40 5
6 100 Purpose and use 101 Manufacturer V Guldmann A/S Graham Bells Vej 21-23A DK-8200 Århus N Tel Fax wwwguldmanncom 102 Purpose The GH3 is a ceiling-mounted hoist, which covers the need for lifting or moving a person in hospitals, nursing homes, institutions, swimming pools, riding schools and private homes Conditions for use The use of the GH3 is subject to the following: The GH3 should only be used by trained personnel The maximum nominal load, 200 kg (440 lbs), 250 kg (550 lbs), 300 kg (660 lbs), 350 kg (770 lbs) respectively, must not be exceeded The instruction offered by Guldmann to all customer groups in connection with the purchase of a ceiling-mounted hoist has been received The helper pays attention to the well-being of the user when using the hoist The hoist is used in rail systems which are installed, tested and approved according to Guldmann s stipulation Only technicians who have been certified by Guldmann may install and test the rail systems The hoist is used with the Guldmann lifting hanger or with other suitable hanger (section 108) The hoist is used with a Guldmann lifting sling or with other suitable slings (section 109) 103 Important/Precautions Read the instructions carefully before using the GH3 and in connection with cleaning and service of the hoist The GH3 s maximum load must never be exceeded The GH3 may only be used to lift a person The red strap for the emergency stop and the emergency lowering must be adjutsed to the helpers reach, and must not be removed The GH3 must not be used where there is a risk of it being splashed with water If a defect appears during use of the GH3, stop using the hoist and contact the Guldmann Service Team for repairs The GH3 is controlled by a microprocessor PCB, which can be damaged by static electricity if touched without the necessary precautions, (see point 107) The electronics may only be serviced by Guldmann approved service technicians 6
7 Re: EMC If electromagnetic or other influences occur between this product and other products, these products must not be used together 104 Load limits on GH3 system Read the label which indicate the maximum load limits for each component The components, eg lifting hanger, lifting sling, etc labelled with the lowest load limit determines the maximum load limit for the entire system This maximum load limit must not be exceeded Please note that the max load may change when different components are used, such as lifting hangers, lifting slings, etc 105 Unpacking and Preparation Visual check of the GH3 If the GH3 is thought to be damaged upon reception, the GH3 must not be used before it has been checked and approved by a qualified person or the Guldmann Service Team Contents of the box GH3 hoist Hand control Transformer Manual Label for rail system Placing a new GH3 Hoist in an existing rail system Please notice, placing a new GH3 hoist in an existing rail system it must be ensured that: The rated max load of the rail system, must be equal or higher than the max load of the new hoist If there is no max load mentioned on the rail system, the rail system must then be checked according to the guideline in the installation manual (distance between bracket according to max load) If the brackets are not visible, then a load test with 1,5 x max load of the hoist must be performed minimum 20 min The deflection of rails must not be higher than 1/200 of the length of the rail If it is not possible to do any of the above mentioned, please contact Guldmann or their representative 7
8 If the rail system can not be rated to the same max load as the hoist, then extra brackets must be installed according to the installation manual (distance between bracket according to max load) Class I equipment Fixed rail systems are class I equipment and must be installed by a qualified technician or by Guldmann Service Team Equipment is disconnected from Supply Mains by breaking the mains breaker switch Class II equipment Mobile equipment is class II epuipment (marked with double-encassed symbol) and can be connected to the mains direct by the user Equipment is disconnected from Supply Mains by detaching the mains plug from the wall outlet Emergency stop device The emergency stop device must be reset in order to connect power to the product To do this, push the yellow reset button (see point 209) 107 Power supply GH3 is equipped with batteries that require regular recharging The power supply for charging and the battery charging point must be connected by a qualified engineer or by Guldmann Service Team The transformer supplied must always be used Safety concerning static electricity (ESD) Service technicians and installers must use an ESD-safety package consisting of a mat, a ground wire, and a bracelet The technician/installer connects the mat to a grounding point, for instance a radiator or a water pipe The technician/installer must then put on the bracelet and connect it to the mat If it is not possible to find a grounding point, the mat and the bracelet must be used as a minimum Only then is it allowed to work with the PC Board or components where it is possible to come into contact with the PC Board 8
9 108 Installation of the lifting hanger before use Lifting hangers from other manufacturers Guldmann shall not be liable for faults or accidents that may occur as a result of using lifting hangers made by other manufacturers If there is any doubt about the selection or use of a lifting hanger, please contact your supplier Fig 1 The lifting hanger can be installed to the lifting strap without the use of any tools Hold the lifting hanger in the right hand and press the yellow button using the thumb as shown (Fig 1) Fig 2a 2 Insert the strap attachment in the slot on the lifting hanger top cover with the open side facing down (Fig 2a, 2b) and release the yellow button (Fig 2c) 3 Rotate the strap attachment to a vertical position (Fig 3) Fig 2b Check that the yellow button has returned to its locked position by checking that it is flush with the cover of the lifting hanger and that the strap attachment can rotate freely Fig 2c 9 Fig 3
10 109 Lifting sling A lifting sling with four to six lifting straps designed for mounting on hooks should be used when using a Guldmann lifting hanger Place the straps on the hooks Make sure that the rubber safety catch returns to its start position, so the straps can not unintentionally fall off Slings made by other manufacturers Guldmann shall not be liable for faults or accidents that may occur as a result of using lifting slings made by other manufacturers If there is any doubt about the selection or use of a lifting sling, please contact your supplier Guldmann shall not be liable for faults or accidents due to incorrect use of the lifting sling, or for reasons of inadequate attention on the part of the carer or user Working with the GH3 The GH3 runs easily in the rail system and does not have any special requirements for space or power in connection with moving Attention can thus be fully focused on the user s functional level and the helper s technique If the hoist is used correctly, the user should only be lifted to the extent that she/he is clear of the surface and should be moved at this height Attaching the lifting sling Place the straps from the lifting sling on the hooks on the lifting hanger Start with the uppermost set of straps (from the back) and then take the lowest set of straps (from the legs) Important! Be careful when applying the lifting sling Check that the straps have been pulled completely through the rubber safety catch and into place in the lifting hanger s hooks before starting lifting the user 10
11 Lifting to and from a seated position When lifting a user from eg a wheelchair, move the GH3 towards the person to be lifted The lifting hanger should be at the same height as the user s chest and should not be moved further in over the user than to approximately mid-thigh position Place the lifting hanger parallel to the user s shoulders Place the lifting sling behind the user s back between the back of the chair and the user s back The centre band of the lifting sling should follow the user s spine As for the slings type Active the strap showing the size of the sling should be opposite the spine Lead the leg straps along the outer sides of the user s shins and beneath the thighs between the hollow of the knees and the hip joints Cross the leg straps in front of the user All four lifting straps are now ready to be attached The lifting sling can now be mounted on the lifting hanger Lifting to and from lying position in bed Bring the lifting hanger over the centre of the person to be lifted Place the lifting hanger parallel to the user s shoulders Turn the user onto his or her side The Basic High sling should be placed so that its top is at the same height as the top of the user s head Now position the sling over the user so that the centre band follows the user s spine Turn the user onto his or her back and pull out the remaining part of the lifting sling Place the leg straps beneath the user s thighs and cross them All four lifting straps are now ready to be attached and the lifting sling can now be mounted on the lifting hanger It is an advantage to elevate the head of the bed so that the user is sitting up Only persons who have received competent instruction regarding the use of lifting equipment and fitting of slings should use the hoist Important! Plan the move Avoid leaving the user in the lifting sling unattended The GH3 lifts quickly and powerfully Before lifting, check that the user is completely free of his/her surroundings The user s head, arms, hands and feet must not be in danger of becoming trapped Be careful with any tubes and wires that are attached to the user Check that the hand control and hand control cable is free of hanger, patient and other object before the hoist is activated up or down moved 11
12 110 Swing kit The swing function is used in conjunction with a transfer eg through a door from one lifting module to another Note: The swing adapter must be ordered separately Fig 1 Installation of swing adapter Before starting a lift involving a swing transfer the swing adapter (Fig 1) must be installed on the lifting hanger (Fig 2 to 5) Fig 2 2 Hold the lifting hanger in the right hand and press the yellow button using the thumb (Fig 2) Insert the swing adapter in the slot on the lifting hanger top cover with the open side facing down (Fig 3a, 3b) and release the yellow button Rotate the swing adapter to a vertical position (Fig 4) Check that the yellow button has returned to its locked position by checking that it is flush with the cover of the lifting hanger and that the swing adapter can rotate freely Install the strap attachment to the swing adapter by sliding the open side of the strap attachment over the flat area of the swing adapter (Fig 5) Rotate the strap attachment and ensure that it moves up on the circular portion of the swing adapter (Fig 6) Fig 3a Fig 3b Fig 4 Fig 5 12 Fig 6
13 111 Using swing kit in doorway Bring the two hoist as close together as possible Adjust the height of the lifting hanger on hoist B so that the transfer can be done without the user touching the floor during the transfer from one hoist to another A B 2 Take the free lifting strap from hoist A and secure it to the swing adapter on the lifting hanger (see 110 figures 5 and 6) In order to lower the free lifting strap on hoist A a slight pull must be applied to the strap A B 3 Lower the lifting hanger using hoist B while lifting the strap on hoist A to perform the swing transfer The transfer has been completed when there is no load on the lifting strap on hoist B A B Disconnect the lifting strap on hoist B from the lifting hanger and raise the strap on hoist B out of the way A B 5 Move the lifting hanger from hoist A to operating height and the doorway transfer is complete 13 A B
14 112 GH3 with horizontal drive motor The GH3 with horizontal drive motor can operate in the rail system Be aware that the drive motor takes time to both accelerate and brake the hoist It is possible to position the hoist with horizontal driving motor with a high degree of accuracy by a brief activation of the hand control The GH3 with horizontal drive motor runs on its own power and it should not be pulled through the rail system 113 GH3 with horizontal drive motor and infrared remote (IR) control The GH3 has an integrated IR receiver which is controlled by the IR remote control The hand control should be left attached to the hoist This means that the hoist can always be operated, in the the event that the IR remote control is mislaid or the battery is uncharged 200 Description of functions Information panel on the GH3 bottom surface Lamp indicator RESET 14
15 201 Pictograms Emergency stop Emergency lowering function RESET Reset emergency stop Direction of travel (horizontal drive motor) denoted by grey arrow 202 Indicator lamps and audio signals Status Indicator lamps Audio signals Possible GH3 Functions Communication Horizontal drive motor Emergency lowering Down Up Off stand by Off All OK Green x x x x x No charging Yellow, after 15 sec 3 x Beep after 60 sec x x x x x Low battery Yellow x x x x x Fault on hoist Battery critical low Yellow Beeps at button activation x x Yellow Beeps at button activation that is not permitted 15 x x x Over load Yellow Beeps at button activation x x Service date exceeded more than 60 days Yellow Beeps at button activation x x x x x
16 203 Operation Hand control The GH3 is switched on automatically when a button on the hand control is pressed 1 2 The GH3 is switched off automatically after approx 8 minutes without activation GH3 Lift Lower GH3 with horizontal drive motor Lift Lower Movement in the direction of the arrow on the GH3 information panel (section 200) Movement in the direction opposite to the arrow on the GH3 information panel (section 200) GH3+ 1 Lift 2 Lower 5 Function selection button (section 205, supplementary modules) 6 Function selection button (section 205, supplementary modules) 7 PDA interface (mini USB) x) GH3+ with horizontal drive motor Lift Lower Movement in the direction of the arrow on the GH3 information panel (section 200) Movement in the direction opposite to the arrow on the GH3 information panel (section 200) Function selection button (section 205, supplementary modules) Function selection button (section 205, supplementary modules) PDA interface (mini USB) x) x) Accessories to CLM module (see Supplementary modules, GH3+ (section 204))
17 Parking the hand control When the hand control is not in use it can be placed on the lifting hanger 2 3 Infrared remote control Lift Lower Movement in the direction of the arrow on the GH3 information panel (section 200) Movement in the direction opposite to the arrow on the GH3 (section 200) Note: In order for the GH3 s lowering function to work, the strap must be carrying a load equal to the minimum capacity for Guldmann s lifting hanger Transport/running in the rail system The GH3 is manually pushed forward in the rail system by the helper The GH3 with horizontal drive motor will run in the rail system when activated by the hand control/remote control 17
18 204 Supplementary modules, GH3+ There are various supplementary modules for the GH3+ Scale module (GH3+ with integrated scale) CLM module (GH3+ with statistical function for management use) Service module (GH3+ with Service module) Menu structure, Supplementary modules GH3+ (Detailed description follows in sections ) Scale CLM Next service Setup KG OK Start Show Setup Scale KG 2480 CLM 1-5 Lifetime total lifts 987 Units Pop-ups Zero Exit Next Exit Chang Next service Service date exceeded call service Scale KG 00 CLM 2-5 Lifetime heavy lifts 232 Units OK Exit Zero Exit Next Exit Chang Low battery Critical low battery CLM 3-5 Last week total lifts 60 Units OK OK Next Exit Chang No charging Fault hoist CLM 4-5 Lifts per week avg 72 OK OK 18 Next Next Exit CLM 5-5 Hoist ID Hoist #1 Exit
19 M Next service Setup ow Setup M 1-5 Lifetime total lifts 987 Units KG Language English Language 4-8 Italianio xt Exit Change Change Change OK M 2-5 Lifetime eavy lifts 232 Units lbs Language 1-8 Dansk Language 5-8 Espanol ext Exit Change OK Change OK Change OK M 3-5 ast week total lifts 60 Units KG Language 2-8 Deutsch Language 6-8 Francaise xt Exit Change OK Change OK Change OK M 4-5 Lifts per eek avg 72 Language 3-8 Svenska Language 7-8 Portuguese BR xt ext Exit M 5-5 Hoist ID Hoist #1 Exit Change OK 19 Change Language 8-8 English Change
20 205 Configuration of supplementary modules, GH3+ Before the GH3+ is put into use, the hoist must be configured Configuration covers language (Scale module/clm module/service module) and the unit for specification of weight (Scale module) Factory setting: Language: English (UK) Unit of weight: kg Configuration of supplementary modules takes place from the GH3+ hand control Setting the language Scale Statistics Next service Setup Language KG English Menu Start Show Setup Change 2 Press any key on the GH3 hand control to activate the hoist When the hoist is activated, the display on the hand control is switched on and the Guldmann logo G appears Select Menu using the function key located immediately below the display and then select until the Setup menu appears in the display 3 Select Setup and then display until the Language menu appears in the Select Change until the preferred language appears in the display, and confirm the selection by pressing OK 5 Then return to Setup Select to return to the start menu 20
21 Setting the units, kg/lbs (Scale module) Scale Statistics Next service Setup Scale KG KG Menu Start Show Setup Change Press any key on the hand control to activate the hoist When the lifting module is activated, the display on the hand control is switched on and the Guldmann logo G appears 2 Select Menu using the function key located below the display 3 Then select until the Setup menu appears in the display Select Setup and then until the Units menu appears in the display 5 Select Change to switch between the units kg and lbs, and confirm the selection by pressing OK 6 Select to return to the start menu 7 The display in the hand control switches off automatically after use (approx 8 min) (See the complete menu summary, section 204, Supplementary modules, GH3+) 206 Scale module (GH3+ with integrated scale module) The GH3+ with scale module (option) provides the facility to determine the user s weight Warning! The integrated scale in GH3+ is not approved to determine mass in medical practice, including the weighing of patients in connection with health monitoring, diagnosis and medical treatment (The provisions for medical weighing are specified in accordance with EEC Directive 90/384) Shock effects The GH3+ with scale module includes high-sensitive sensors to register mass corresponding to the nominal recommended load The sensors are highly sensitive and can be damaged by the effects of shock, for example pulling the GH3+ at extreme speed into an end stop Operation Always reset the GH3+ scale module before weighing takes place When resetting the unit, the lifting hanger and the desired lifting sling must be attached under the hoist 21
22 Resetting the unit (tara) Scale KG Scale 2480 KG Scale 00 KG Menu Start Zero Exit Zero Exit 2 Press any key on the hand control to activate the hoist When the lifting module is activated, a display on the hand control is switched on and the Guldmann logo G appears Select Menu using the function key located immediately below the display 3 Then select until the Scale menu appears in the display Then select Start 5 Park the hand control on the lifting hanger (If the helper pulls the hand control during weighing, this will affect the result of the weighing process) 6 When the lifting hanger with the lifting sling is at rest, select Zero to reset the GH3+ scale module The scale module has now been reset and weighing can commence 22
23 Weighing Scale KG Scale 2480 KG Menu Start Zero Exit Always reset the GH3+ scale module before weighing takes place, see section entitled Resetting the unit 2 3 Place the lifting sling on the user and attach it to the lifting hanger Lift the user with care Park the hand control on the lifting hanger 5 Select Menu using the function key located immediately below the display and then select until the Scale menu appears in the display 6 Then select Start 7 When the sling and the user are at rest and hanging freely, the current weight can be read on the display (The weight can be read to an accuracy of 1 decimal place) 8 Select Exit to return to the main menu Note: The display in the hand control switches off automatically after use (approx 8 min) 23
24 207 CLM module (GH3+ with statistical function for management use) The GH3+ with CLM module (option) includes a management tool that saves important information on the use of the lifting module and which can be used to evaluate the system s efficiency and utilisation, as well as to optimise its use and hoist name/location The following data can be shown on the hand control s display: number of lifts, number of heavy lifts, number of lifts in last week, average number of lifts per week As an additional option, by connecting a PDA/Net Book to the hand control it is possible to gain access to a number of other saved data, eg the number of lifts since the last strap change, number of critically low battery readings, number of weighings, total lifting time, etc This information can be downloaded and used for further analysis (PDA/Net Book readouts requires a PDA/Net Book with Guldmann CLM software) Number of lifts, total Number of heavy lifts, total Number of lifts, last week Average number of lifts per week A lift is registered automatically when the following events are registered simultaneously Hand control is activated (Direction UP) for more than 2 seconds The load on the lifting strap is registered as being within the range: 15 kg Recommended load kg (33 lbs Recommended load lbs) Total includes the number of lifts performed after the lifting module was first taken into use A heavy lift is registered automatically when the following events are registered simultaneously Hand control is activated (Direction UP) for more than 2 seconds The load on the lifting strap is registered as being within the range: 150 kg Recommended load kg (330 lbs Recommended load lbs) Total includes the number of heavy lifts performed after the lifting module was first taken into use The total number of lifts performed within the last seven calendar days Average number of lifts per week (performed after the lifting module was first taken into use) The data for Number of lifts, last week and Average number of lifts per week can, if necessary, be reset using a PDA/Net Book 24
25 Operation Menu Scale Start KG CLM Show CLM 1-5 Lifetime total lifts 987 CLM 2-5 Lifetime heavy lifts 232 CLM 3-5 Last week total lifts 60 CLM 4-5 Lifts per week avg 72 CLM 5-5 Hoist ID Hoist #1 Next Exit Next Exit Next Exit Next Exit Next Exit 1-5 Number of lifts, total 2-5 Number of heavy lifts, total 3-5 Number of lifts last week 4-5 Average numbers of lifts per week 5-5 Hoist ID Press any key on the GH3+ hand control to activate the hoist When the lifting module is activated, the display on the hand control is switched on and the Guldmann logo G appears 2 Select Menu using the function key located below the display 3 Then select until the CLM menu appears in the display 5 6 Then select Show Then select Next until the required information appears in the display Select Exit to return to the main menu Note: The display on the hand control will automatically revert to the screensaver after approx 8 min Accessories for the CLM module, GH3+ The CLM module includes an extended management menu which can be operated via a PDA/Net Book (with Guldmann CLM software installed) The PDA/Net Book is connected to the GH3+ hand control via a mini USB plug located in the base of the hand control (see section 204) Contact supplier or the Guldmann Service Team for further information about CLM accessories 25
26 208 Service module (GH3+ with service module) The GH3+ with Service module (option) saves all of the information about time and indication of next safety/service inspection The GH3+ with Service module specifies the date of the next safety/service inspection Operation Scale CLM Next service KG Menu Start Show Press any key on the hand control to activate the hoist When the lifting module is activated, a display on the hand control is switched on and the Guldmann logo G appears 2 Select Menu using the function key located immediately below the display 3 Then select display until the Next service: menu item appears in the Read off the date of the next safety/service inspection (Year, Month, Date) 26
27 Pop-Up s for Service module (supplementary module) There are two different Pop-Up s (brief messages on the display) on the GH3+ with Service module These pop-up s notify the user of upcoming and exceeded dates for service inspections Both Pop-Up s appear immediately after the hand control has been switched on Pop-Up s before and after Service Date Next service Service done Next service Pop-Up, 30 days The next service inspection must be undertaken within 30 days Select OK to return to the main menu (returns automatically after approx 5 seconds) Next service If service is not performed Service date exceeded call service Exit 2 Pop-Up, Service date exceeded The date of the service inspection has been exceeded, contact the Guldmann Service Team Select Exit to return to the main menu (returns automatically after approx 5 seconds) Attention! If the service date is exceeded by more than 60 days, the hoist makes an acoustic signal, at any button activation The Acoustic signal can be disabled by the Guldmann Service and Information Consol software Note: The display on the hand control will automatically revert to the screensaver after approx 8 minutes 27
28 209 Safety functions The emergency stop and emergency lowering device should only be used in an emergency In the event that it is necessary to use the safety functions, the fault must be identified and rectified before the GH3 is taken into use again Please contact your supplier Emergency and lowering strap The red strap has the following functions: One pull: Emergency stop is activated Constant pull (2 steps): Emergency lowering is activated It will work with following load: GH3 up to 250 kg/550 lbs from approx load 80 kg/176 lbs GH3 from 300 kg/660 lbs from approx load 120 kg/264 lbs Emergency stop If the GH3 does not stop/react to the hand control when the GH3 is in use, pull the red strap and all lifting/lowering/horizontal driving functions (except emergency lowering) are deactivated When the emergency stop is activated, the hoist will not function The green lamp is switched off Reset emergency stop Reset the emergency stop by pressing the yellow button on the bottom of the hoist The yellow button that appears when the emergency stop is pulled, must be pressed manually before the GH3 is ready for use After deactivating the emergency stop, activate the hand control twice 28
29 Emergency lowering function, electric If the GH3 fails, the electrical emergency lowering function is used to lower the user safely The emergency lowering function is operated by a constant pull on the red strap that is used for the emergency stop Electric emergency lowering will work with following load: GH3 up to 250 kg/550 lbs from approx load 80 kg/176 lbs GH3 from 300 kg/660 lbs from approx load 120 kg/264 lbs 2 When releasing the red strap, the emergency lowering function will be replaced by the emergency stop Emergency lowering function, mechanical If the electrical emergency lowering function in the GH3 fails, the emergency lowering can be done mechanically Remove the side covers Release the side covers from the top of the hoist by means of a gentle push on the fixing points on each side The covers are tipped free of the hoist and can be removed Then release the hoist s motor by turning the handle bearing the words EMERGENCY DOWN This handle is located immediately behind the side cover and must be turned clockwise Note: For hoists with a recommended load of more than 250 kg (550 lbs), there are two motors and therefore two handles to activate, one on each side 29
30 3 When the brake(s) has/have been released, the user will be lowered slowly If the total weight of the user and the lifting accessories is low (eg less than 50 kg (110 lbs), it may be necessary to help the user down by turning the large belt wheel located on the opposite side of the handle and in the direction of arrow marked on the belt wheel Note: A GH3 with a recommended load of more than 250 kg (550 lbs) has two motors, and therefore two belt wheels to activate, one on each side Warning! After the mechanical emergency lowering function has been activated in the GH3, the hoist MUST be serviced by a qualified technician or by the Guldmann Service Team 210 Charging/connection The GH3 is automatically charged troughout in straight rails This guarantees the hoist functionality and maintains the batteries to ensure a long lifetime The indicator lamp on the bottom of the hoist turns yellow if the charge status becomes low or if there is a complete interruption to the charging function The GH3 then has a limited number of lifts available at a time and must be re-charged The transformer must be connected and switched on before charging can take place A green indicator lamp on the transformer indicates that it is connected and switched on 211 Accessories Guldmann ABC slings and lifting hangers Obtain a brochure from your distributor, manufacturer or at wwwguldmanncom Extension strap The extension strap is used where the distance between the lower part of the rails and the floor exceeds 35 m (11' 7") The extension strap is available as an accessory Batteries NiMH Battery 24V/2800mAh, Guldmann type number Transformer Transformer, Class 1, Guldmann item number Transformer, Class 2, Guldmann item number (EU), (US/CAN) 30
31 300 Transport and storage Guldmann recommends that the GH3 is always transported and stored in the original packaging Key to symbols on the GH3 packaging: C F 30 70% hPa The GH3 should be stored at: Temperatures between -10 and +40 C / 14 and 104 F A relative air humidity of between 30 and 70 % An air pressure of between 700 and 1060 hpa This side up 400 Maintenance and storage 401 Cleaning Clean the GH3 with a damp cloth and mild handwash detergent Do not use strong acids, bases or alcohol to clean the GH3 Never clean GH3 in an autoclave 402 Storage See 300 For long-therm storage, disconnect the battery plugs and the plug from the battery at the charging PCB 403 How to prevent/avoid corrosion? When the GH3 is mainly used in an corrosive environment, eg swimming pool, the hoist must be ordered with a special corrosion-preventive surface treatment 404 The owner s daily maintenance duty Check the lifting sling for wear and damage before use Do not use the lifting sling if it is damaged or defective Do not use the GH3 if the lifting strap is damaged or defective Contact your supplier and order a new lifting sling or a replacement of the lifting strap Replacement of the lifting strap must only be performed by the Guldmann Service Team or by a qualified technician in accordance with Guldmann s instructions 31
32 405 Disposal of the GH3 including batteries Local and national regulations on environmentally correct recycling must be observed Batteries (type NiMH) must always be delivered to an approved recycling point 500 Service and lifetime 501 Lifetime The GH3 has an expected lifetime of 15 years, on the condition of coorect use and correct service inspections, see section 502 Replacement of components Replacement of batteries, PCBs and lifting straps must be performed by a qualified service technician or the Guldmann Service Team 502 Safety/service inspections In accordance with international standard EN/ISO Hoist for the transfer of disabled persons Requirements and test methods an inspection should be performed on the hoist at least once a year Guldmann recommends that regular safety/service inspection is performed at least once a year with regard to the pattern of usage Inspection of the GH3 must be performed by a qualified service technician or the Guldmann Service Team In connection with the purchase of the GH3, Guldmann may offer a service agreement for this inspection NB! The GH3+ with service module may only be serviced by the Guldmann Service Team or by a qualified service technician with access to the PDA/Net Book with Guldmann software During the safety/service inspection a report must be prepared on what was checked and replaced Parts that are worn or defective must be replaced with new parts from Guldmann Spare parts drawings and documentation can be obtained from the manufacturer or supplier Documentation/checklist regarding safety/service inspection can be obtained from the manufacturer or supplier 32
33 503 Troubleshooting 2 3 The GH3 does not respond to the hand control s keys Check the emergency stop is not activated Check the hoist has power supply Check the transformer is switched on and connected to the rail system Contact the Guldmann Service Team 600 Classification CE marking 23W1 Medical equipment with respect to electrical shock, fire and mechanical hazards only In accordance with UL , CAN/CSA c222 No 6011 Type B in accordance with UL/EN Read the manual before use Must not be disposed of as standard household waste, must be recycled Class I equipment: Class II equipment: Permanent installation with protective ground Non-permanent installation without protective ground The equipment is not suitable for use in the presence of flammable mixtures Degree of protection against harmfull ingress of liquids (water) Hoist IP20 Hand control IP44 Remote control IP20 Transformer IP20 33
34 Examples of serial number label Lifting module max 250 kg / 550 lbs Part no xxxxxx Prod date yyyy-mm-dd Serial no xxxxx 33V AC, 25 A, IP20 CONTINUOUS OPERATION WITH SHORT-TIME LOADING wwwguldmanncom GH W1 INTERNALLY POWERED EQUIPMENT 24V DC Barcode 128C Transformer Class 1 Type DK Input 115V AC Hz, 1A Input 230V AC Hz, 0,5A Output 33V AC 2,5A Prod date yyyy-mm-dd Serial no xxxxx 23W1 IP20 wwwguldmanncom Barcode 128C Transformer Class 2 Transformer Class 2 Use within US/CAN Use within EU Type DK Input 115V AC Hz, 1A Output 33V AC 2,5A Prod date yyyy-mm-dd Serial no xxxxx 23W1 IP20 wwwguldmanncom Barcode 128C Type DK Input 230V AC Hz, 0,5A Output 33V AC 2,5A Prod date yyyy-mm-dd Serial no xxxxx 23W1 IP20 wwwguldmanncom Barcode 128C Lifting hanger Hand control max xxx kg/xxx lbs Part no Edition Prod date Serial no xxxxxx xxx yyyy-mm-dd xxxxx Part no xxxxxx Edition xxx Date xxxx-xx-xx IP44 Barcode 128C V Guldmann A/S wwwguldmanncom 34
35 700 Certificates UL UL No EN/ISO10535 HMI No 0849A, 0914A, 0915A 800 Technical specifications GH3 Lifting modules, version type nomenclature Guldmann hoist type Product line Load in kg Number of lifting straps Number of lifting motors Number of horizontal drive motors Scale module CLM module Service module User interface GH3 (x) xxx x x x x x x x GH None : 0 Scale : Twin None : 0 CLM : 1 Config : 2 None : 0 Service: 1 Config : 2 Hand control: 0 IR : 1 GH3 X Y Z Z Z Q Q Q Q Example: GH GH Hand control w/o Service module w/o CLM module Scale module 2 horizontal drive motors 2 lifting motors 1 lifting strap Safe Working Load SWL: + Ceiling hoist, type GH3
36 Functions Lifting capacity, SWL 200 kg (440 lbs), 250 kg (550 lbs) 300 kg (660 lbs), 350 kg (770 lbs) Operation Hand control / IR Sound level 52 db (A) Horizontal speed 18 m/min (709 inch/min) GH3 GH3+ Lifting speed 85 kg (187 lbs) load 40 mm/sec (16 inch/sec) 60 mm/sec (24 inch/sec) 150 kg (330 lbs) load 40 mm/sec (16 inch/sec) 60 mm/sec (24 inch/sec) Max capacity load, SWL 40 mm/sec (16 inch/sec) 55 mm/sec (22 inch/sec) Max 5 kg (11 lbs) load 100 mm/sec (39 inch/sec) 100 mm/sec (39 inch/sec) Weight and materials SWL 200 kg (440 lbs), 250 kg (550 lbs) Own weight 96 kg (211 lbs) with horizontal drive motor 105 kg (231 lbs) with scale module and horizontal drive motor 111 kg (245 lbs) SWL 300 kg (660 lbs), 350 kg (770 lbs) Own weight 142 kg (31 lbs) with horizontal drive motor 159 kg (35 lbs) with scale module and horizontal drive motor 173 kg (38 lbs) Covers Impact-resistant UL 94 V-0 flame retardant recyclable plastic Digital Scale Specifications (Non medical) Optional for GH3 Capacity 0 - SWL Accuracy +/- 01 % at max load Display resolution (d) 01 kg (022 lbs) Repeatability < 01 kg at kg (0-440 lbs) < 02 kg at kg (0-770 lbs) Minimum weight 5 kg (11 lbs) Display type LCD in Hand Control 36
37 Dimensions A 580 mm (228 inch) B 345 mm (136 inch) C 156 mm (61 inch) D 184 mm (72 inch) E, min 82 mm (32 inch) F, min 445 mm (175 inch) G 2500 mm (984 inch) Depth of hoist 205 mm (81 inch) Safety Emergency stop Yes, mechanical and electrical Emergency lowering device Yes Control of lifting strap Yes Cut-off angle 45 along the rail 10 across the rail A B E C D F G 37
38 Electronics On/off Automatic when used Soft start/stop Overload protection Automatic Low Battery protection Automatic Power supply 33V AC, 25 A Supply voltage, transformer 115/230V AC, 50/60 Hz Battery 24V NiMH SWL: 200 kg (440 lbs), 250 kg (550 lbs) 28 Ah SWL: 300 kg (660 lbs), 350 kg (770 lbs) 56 Ah Continuous operation with short time loading with: 3 hours without recharging 10/90% (2 min operation/18 min pause) Max number of lifts in series with: 85 kg (187 lbs) 55/1000 mm (394 inch) SWL: 200 kg (440 lbs), 250 kg (550 lbs) 28/1000 mm (394 inch) SWL: 300 kg (660 lbs), 350 kg (770 lbs) 40/1000 mm (394 inch) Max charging time at 25ºC: SWL: 200 kg (440 lbs), 250 kg (550 lbs) 2 hours SWL: 300 kg (660 lbs), 350 kg (770 lbs) 4 hours Operating temperature 10ºC-35ºC (50ºF-95ºF) Degree of protection against harmful ingress of liquids (water) Hoist IP 20 Hand control IP 44 Remote control IP 20 Transformer IP 20 38
39 900 EC-Declaration of conformity EC-DECLARATION OF CONFORMITY Manufacturer V Guldmann A/S Graham Bells Vej 21-23A DK-8200 Aarhus N EAN country code: 57 EAN distribution No: Phone Fax Representative Company Address Country Phone Hereby declare that Product GH3 / GH3+ incl lifting hanger, suspension and charging system Type No GH3X Y ZZZ QQQQ x) x) See GH3 lifting modules, version type nomenclature was manufactured in conformity with the provisions in according to the Council Directive 93/42/EEC of 14 June 1993 Class 1 EN/ISO 10535:2006 Hoists for the transfer of disabled persons - requirements and test methods UL/EN :2003 Medical electrical equipment - Part 1-1: General requirements for safety IEC/EN : Medical electrical equipment , +A1:2006 Part 1: General requirements for safety - 2: Collateral standard: Electromagnetic compatibility Place and day of issue Product responsible 39 Skejby 8 June 2009 Technical Manager
40 USA and countries outside the EU A Users guide Before using the product, read the entire operation manual including all warranties B Warranties The Guldmann lifting equipment is designed to be used for the lifting, transferring, and transporting of a person with a physical handicap who are not able to physically self transfer or who are temporarily incapacitated by illness, anesthesia or other causes This lifting equipment is designed to relieve the users, their caregivers, and nursing personnel in the task of lifting elderly or disabled people, thereby minimizing the risk of back injury during such lifting and transfer operations If the product is used irresponsibly or for any use other than that described above or in the enclosed written instructions, the manufacturer s warranty will be nullified and rendered void There are no warranties which extend beyond the description in the enclosed written instructions Guldmann warrants that its lifting equipment is free from defects in materials and workmanship under normal use Guldmann warrants that the lifting equipment itself will perform substantially in accordance with the specifications set forth in the documentation provided with the equipment The above express warranties are made for a period of 365 days from the date the lifting equipment is delivered to you as the first user The distributor will replace any lifting equipment which proves defective in materials or workmanship, without additional charge, on an exchange basis The distributor will either replace or repair without additional charge any Guldmann lifting equipment that does not perform in substantial accordance with the specifications of the document Guldmann does not warrant that the functions contained in the lifting devices will meet your requirements or that the operation of the services will be uninterrupted or error-free The warranty does not cover any of the part of the lifting equipment which has been subject to damage or abuse by you The warranty does not cover any part of the lifting equipment which has been altered or changed in any way by you or others Guldmann is not responsible for problems caused by changes in the operating characteristics of the operating system which are made after the delivery of the lifting equipment Any implied warranties including any warranties of merchant ability or fitness for a particular purpose are limited to the term of the express warranties 40
41 Guldmann shall not in any case be liable for special, incidental, consequential, indirect or other similar damages arising from any breach of these warranties even if Guldmann or its agent has been advised of the possibility of such damages You must call Guldmann or your distributor for an authorization to return any defective item during the warranty period If your distributor is unable to correct your problem by telephone, you will be provided with a return authorization number and address for returning the defective item for warranty service or replacement You must insure any defective item being returned because Guldmann does not assume the risk of loss or damage while in transit Do not return items or warranty service to Guldmann The warranties set forth are in lieu of all other express and implied warranties, whether oral, written or implied, and the remedies set forth above are your sole and exclusive remedies Only an authorized officer of Guldmann may take modifications to this warranty, or additional warranties binding on Guldmann Accordingly, additional statements such as advertising or presentations, whether oral or written, do not constitute warranties by Guldmann and should not be relied upon as such The warranty gives you specific legal rights, and you may also have the other rights which vary from state/country 41
42 42
43 43
44 V Guldmann A/S Corporate Office: Graham Bells Vej 21-23A DK-8200 Århus N Tel Fax info@guldmanncom wwwguldmanncom Guldmann Inc 5525 Johns Road Suite 905 Tampa, FL Tel Tel Fax info@guldmannnet wwwguldmannnet 44
GB/US... GH3/GH3+ Ceiling Hoist
GB/US.... GH3/GH3+ Ceiling Hoist Vers. 6.00 23W1 1 GH3 Lifting modules, version type nomenclature Guldmann hoist type Product line Load in kg Number of lifting straps Number of lifting motors Number of
SR 801. DK... Digitalvægt... 2 GB... Digital Scale... 7 D... Digitalwaage... 12 S... Digitalvåg... 17 U.S.A. and countries outside the EU...
SR 801 DK.... Digitalvægt.......................... 2 GB.... Digital Scale......................... 7 D...... Digitalwaage....................... 12 S...... Digitalvåg.......................... 17 U.S.A.
GB/US... GH2 Ceiling Hoists
GB/US.... GH2 Ceiling Hoists GH2 Ceiling Hoists Hoist numbers: 120001 - xxxx 1.00......... Purpose and use.............................................. 3 1.01........ Manufacturer..................................................
GB/US... GH2 Ceiling Hoists. Vers. 2.01
GB/US.... GH2 Ceiling Hoists Vers. 2.01 1 GH2 Ceiling Hoists Hoist numbers: 120001 - xxxx 1.00......... Purpose and use.............................................. 3 1.01........ Manufacturer..................................................
GB/US... DH 2000. Vers. 1.00
GB/US.... DH 2000 Vers. 1.00 1 DH 2000 Ceiling-mounted hoist Item nos: 12075-000 12075-100 1.00......... Purpose and use.............................................. 3 1.01......... Manufacturer..................................................
Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used
Luna/200 Luna/275 Ceiling hoist User instruction! Important - warning This manual must be read before the Luna is used This manual is intended for technicians, installers, therapists and other personnel,
US... Guldmann mobile lifter. Vers. 2.00
US....... Guldmann mobile lifter Vers. 2.00 Guldmann mobile lifter Item nos: 11220-xxx 11230-xxx 11240-xxx 1.00......... Purpose and Use.............................................. 3 1.01......... Manufacturer..................................................
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Max load: 450/625lbs, 205/285kg
Rise450/625M 450/625T Manual Max load: 450/625lbs, 205/285kg The ceiling track lift Rise 450/625 has been developed for use in combination with the correct lifting accessories for convenient and trouble-free
Uno 102. Product Description. Instruction Guide
Uno 102 Instruction Guide English 7EN150104-04 2013-08-22 Applies to the following models: Uno 102 EE Prod. No. 2010004 Product Description Uno 102 is a mobile lift with electric raising and lowering of
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
7 High-Resolution Digital Photo Frame
TM 16-1003 User s Guide 7 High-Resolution Digital Photo Frame One demo photo included, as illustrated Please read this user s guide before using your new photo frame. Package contents Photo Frame AC Adapter
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1
ITC-BTTN Cellular Bluetooth Gateway Owner s Manual 1 2 Table of Contents Introduction...3 Package Contents...3 XLink Connections Diagram...4 Setup...5 Pairing your Bluetooth Cell Phone to the XLink...6
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4
user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Guldmann GB/US-1197/03/07 # 944126
V. Guldmann A/S Corporate Office: Graham Bells Vej 21-23A DK-8200 Århus N Tel. +45 8741 3100 Fax +45 8741 3131 E-mail [email protected] www.guldmann.com Guldmann Inc. 5525 Johns Road Suite 905 Tampa, FL
GB... Guldmann mobile lifter. Vers. 2.00
GB....... Guldmann mobile lifter Vers. 2.00 Guldmann mobile lifter Item nos: 11220-xxx 11230-xxx 11240-xxx 1.00......... Purpose and Use.............................................. 3 1.01......... Manufacturer..................................................
GB...LP1 Lifting platform
GB.......LP1 Lifting platform LP1 Lifting platform Item nos: 13015-xxx 1.00......... Purpose and Use............................................. 3 1.01......... Producer.....................................................
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle
OWNER S MANUAL US Permolock C3 Docking system for Power wheelchair in vehicle How to contact Permobil Head Office of the Permobil group Permolock C3 Docking system for electric wheelchair in vehicle Produced
FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL
FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT SAFETY INSTRUCTIONS
Instructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL
Limited Warranty OWNER S MANUAL Audiovox Corporation (Audiovox) warrants this product against defects in materials or workmanship for one (1) year from the date of purchase. During this period, this product
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Nokia Bluetooth Headset BH-800 User Guide. 9246974 Issue 2
Nokia Bluetooth Headset BH-800 User Guide 9246974 Issue 2 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-24W is in conformity with the provisions
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
Universal Wireless Effects Controller USER S GUIDE SA115
Universal Wireless Effects Controller USER S GUIDE SA115 Welcome Thank you for purchasing this Hot Hand 3 Universal Wireless Effects Controller. We hope that the new functionality of the Hot Hand 3 unit
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
Patient Slings. Owner s Operator and Maintenance Manual. DEALER: This manual must be given to the user of the product.
Owner s Operator and Maintenance Manual Patient Slings DEALER: This manual must be given to the user of the product. USER: BEFORE using this product, read this manual and save for future reference. For
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
DK...Ramper... 3 GB...Ramps... 10 D...Rampen... 17 S...Ramper... 24 F...Rampes transportables... 31 US...Ramps... 39
DK.......Ramper........................... 3 GB.......Ramps........................... 10 D........Rampen.......................... 17 S........Ramper.......................... 24 F........Rampes transportables.................
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.
Owner s Manual 1 Dear Customer, Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully. User Memo: Date of purchase: Dealer name: Dealer address:
Nokia Bluetooth Headset BH-109
Nokia Bluetooth Headset BH-109 Issue 1.0 2 Introduction About your headset With Nokia Bluetooth Headset BH-109, you can handle calls hands-free, even when you are using two mobile devices at the same time.
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
User Manual (English)
User Manual (English) Table of Contents General Safety Information...2 Fueltank UNO Components...3 Charging the Fueltank UNO...4 Using the Fueltank UNO...5 Power Saving Mode...6 Checking the Fueltank UNO
Unpacking, Installation, and Customization
Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................
Nokia Bluetooth Headset BH-607. Issue 2. 1
Nokia Bluetooth Headset BH-607 2 3 1 4 5 6 7 8 9 11 10 Issue 2. 1 12 13 14 DECLARATION OF CONFORMITY Hereby, NOKIA CORPORATION declares that this BH-607 product is in compliance with the essential requirements
Nokia Bluetooth Headset BH-108 9220721/1
Nokia Bluetooth Headset BH-108 1 2 3 4 5 6 7 8 9 9220721/1 DECLARATION OF CONFORMITY Hereby, NOKIA CORPORATION declares that this BH-108 product is in compliance with the essential requirements and other
Nokia Bluetooth Headset BH-100 9255557/1
Nokia Bluetooth Headset BH-100 6 7 9 8 10 9255557/1 DECLARATION OF CONFORMITY Hereby, NOKIA CORPORATION declares that this HS-78W product is in compliance with the essential requirements and other relevant
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
Thank you for your recent purchase of the Exerciser 2000. Exerciser 2000 Elite Platinum Series. Own e r s Ma n u a l
Exerciser 2000 Elite Platinum Series Own e r s Ma n u a l LED Timer Thank you for your recent purchase of the Exerciser 2000 Elite MultiSpeed. The Exerciser 2000 Elite is ETL approved, which insures you
GoFit Platinum Power Vibe
GoFit Platinum Power Vibe GFVT011 GoFit Platinum Pty Ltd Phone 1800 446 348 fax 1300 446 348 www.gofit.com.au IMPORTANT PRECAUTIONS When using an electrical appliance, the basic following precautions
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
E&P HYDRAULICS Remote control EPRC-01 Level System Camper
USER S GUIDE E&P HYDRAULICS Remote control EPRC-01 Level System Camper 1 Copyright 2012, E&P Hydraulics This manual is copyrighted, with all rights reserved. Under the copyright laws, this may not, in
User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:
User Manual Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included: 1: Display Console 1: Control Box 2: Encoder (Wires attached) (Not Shown) 1: 5v Power Supply
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
ClearView+ User Manual
ClearView+ ClearView+ User Manual Rev. 2.0, December 2005 All rights, in particular the rights of reproduction as well as translation, are reserved. No parts of this manual may be copied, in any form whatsoever,
19 LED Tube Controller ORDERCODE 41003
19 LED Tube Controller ORDERCODE 41003 Congratulations! You have bought a great, innovative product from Showtec. The Showtec 19 LED Tube Controller brings excitement to any venue. Whether you want simple
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL
Wolverine 35mm Film to Digital Converter Model F2D USER MANUAL Version 1.01 December 2008 TABLE OF CONTENTS DESCRIPTION PAGE Table of Contents 1 Before Using the F2D Converter 3 FCC Certifications 3 Warning
HP ProDisplay P17A LED Backlit Monitor. User Guide
HP ProDisplay P17A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com
How To Service A Paper Shredder
Paper shredder 20-2HS 80C POWERSHRED OPERATING INSTRUCTIONS NOTICE D'UTILISATION MANUAL DEL PROPIETARIO BETRIEBSANLEITUNG 20 80 20C 80C 20-2HS Edition 0/0.70.999.0 Edition 0/0 20-2HS 80C Paper shredder
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-11W is in conformity with the provisions
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
1 Ton Telescoping Gantry Crane
1 Ton Telescoping Gantry Crane 41188 Gantry Crane Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. When unpacking, make sure that the product
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960 This manual covers installation and operation procedures for BNC AM members: Berkeley Nucelonics - 2955 Kerner Blvd. San Rafael, CA 94901 - (415)453-9955 -
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
Digital Fingerprint safe
Digital Fingerprint safe Model 96846 Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product
MULTI XS 3600. Battery charger. For lead-acid batteries 1,2-120Ah
MULTI XS 3600 Battery charger For lead-acid batteries 1,2-120Ah User s Manual and a guide to professional battery charging For Starter/Deep Cycle batteries EN INTRODUCTION Congratulations on your purchase
XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design
XPanel V2 Remote Control Panel User Manual XILICA Audio Design Important Safety Instructions 1. READ THESE INSTRUCTIONS All the safety and operating instructions should be read before the product is operated.
HP ProDisplay P19A LED Backlit Monitor. User Guide
HP ProDisplay P19A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying
Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.
TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY. Table of Contents Page No. 1. Turn the main power switch located on the back-side
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions
THE NEW GENERATION IN TECHNOLOGY NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking Operating Instructions Table of Contents Important Safeguards... 3 Parts... 6 Controls... 6 To Set Up... 7 ipod/iphone
Nokia Bluetooth Headset BH-200 User Guide
Nokia Bluetooth Headset BH-200 User Guide 1 9246085 Issue 2 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-58W is in conformity with the provisions
PAPER SHREDDER PRS-F-01 USER MANUAL
PAPER SHREDDER PRS-F-01 USER MANUAL INSTALLATION Only operate this product from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult an
LED Security Spotlight User Manual
MOT ION-TR ACKING LED Security Spotlight User Manual www.jascoproducts.com 1-800-654-8483 2 TABLE OF CONTENTS Parts List 3 Questions? Missing Parts? 4 Installation (Wall mount) 6-9 Installation (Eave mount)
READ FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting
Congratulations on your purchase of the AT&T U-verse TV Point Anywhere RF Remote Control. This product has been designed to provide many unique and convenient features to enhance your AT&T U-verse experience.
Hydraulic Transmission Jacks Operating Instructions & Parts Manual
Blackhawk Automotive is a Licensed Trade Mark Made by SFA Companies, Kansas City, MO Hydraulic Transmission Jacks Operating Instructions & Parts Manual Model BH7011 BH7210 Capacity 1/2 Ton 1 Ton SFA Companies
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
Jabra BIZ 2400 USB USER MANUAL
Jabra BIZ 2400 USB USER MANUAL 1 2011 GN Netcom A/S. All Rights Reserved. This user guide is published by GN Netcom A/S. The information in this user guide is furnished for informational use only, is subject
INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
INSTRUCTION MANUAL IM042 Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TABLE OF CONTENTS SUBJECT PAGE Safety Instructions... 3 Descriptions and Specifications...
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
15 Digital Photo Frame Instructional Manual
15 Digital Photo Frame Instructional Manual aluratek.com mnl M10054 ADMPF315F Copyright 2011 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Close-up... Remote Control Close-up... Package Contents...
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
