User s Manual Advanced Wind/Solar Hybrid Controller
|
|
|
- Alexia Chandler
- 9 years ago
- Views:
Transcription
1 User s Manual Advanced Wind/Solar Hybrid Controller Model WWS10A-48 Version 1.0
2 Notes 1. Thank you very much for purchasing Wind/Solar Hybrid Controller made by Neoenerji Corp. Please read the instructions carefully before installation and usage and keep it properly. 2. The installation operation must be done by experienced technical personnel and be strictly in accordance with the using manual to ensure the product can work properly. 3. This product should be avoided long-term exposure to corrosive gas and moisture environment. 4. Do not put this product in wet, rain, exposure, severe dust, shock, corrosion and strong electromagnetic interference environment. 5. Do not open the shell to repair this product by yourself.
3 CONTENTS 1. General Description 1 2. Model Description.2 3. Features.3 4. Operational Regulations LCD Operation and Display Instructions Description of the Key Displaying Contents Description Browsing Parameters and Output Modes Description Manual Brake Setting 6 6. Control Software Parameters 8 8. Abnormal Phenomenon and Treatment..10
4 1. General Description The advanced wind/solar hybrid controller is specially designed for high-end small-scale wind/solar hybrid system and especially suitable for wind/solar hybrid power generation system system and wind/solar hybrid monitoring system. It can simultaneously control the wind turbines and solar batteries on the battery for safe and efficient charging. The controller adopts PWM to control wind turbine and solar cell charge the battery with voltage limitting and current limitting, namely, the controller will charge battery with current limitting when battery power is low and charge battery with voltage limitting when battery power is high. When the total charge current of wind turbine and solar cell is lower than current limitting point, the controller will charge the battery with the whole power generated by wind turbine and solar cell. When the total charge current of wind turbine and solar cell is more than current limitting point, the controller will charge the battery with the current limitting point, the excess energy will be unloaded by PWM. When battery voltage is lower than voltage limitting point, the controller will charge the battery with the whole power generated by wind turbine and solar cell. When battery voltage is up to voltage limitting point, the controller will charge battery with voltage limitting point and the excess power will be unloaded by PWM. For specify wind turbine, the controller can achieve accurate speed control, namely, you can set the stop rotation speed. When the wind turbine exceeds this speed, the controller will stop the wind turbine working and the controller will not run the wind turbine untill 10 minutes later. The controller adopts LCD module especially designed for wind/solar hybrid system. The LCD can display battery voltage, wind turbine voltage, photoelectric voltage, wind power, PV power, wind turbine current, PV current and battery power status. Users can browse the parameters through the four keys of LCD The controller is equipped with dedicated remote monitoring software. The software can monitor system status in real-time, such as battery voltage, wind turbine voltage, solar battery voltage, battery charging current, wind turbine charging current, solar charging current, battery charging power, solar charging power, wind turbine charging power, fan speed and so on. The software can configure and modify the system parameters, while the software can control running status of wind turbine and load
5 In addition, the controller has perfect protection functions, including: solar cells reverse charging, solar cells anti-reverse, battery over charge, battery anti-reverse, lightning protecting, wind turbine current limitting, wind turbine automatic brake and manual brake. The low-voltage charging module is optional. The module will enable wind turbine to charge the battery under low-speed. Because the wind turbine has low energy at low speed, so the charging current should not be too large when the fan speed is slow. The low-voltage charging module enables the wind turbine to charge the battery with constant input impedance under low-voltage charging status, namely, the charging current is proportional to charging voltage. Depending on the different characteristics of wind turbines, the input impedance can be modified through serial communication. In addition, users can set wind turbine start charge voltage point through serial communication. Only when the wind turbine voltage is greater than the wind turbine start charging voltage, the wind turbine will charge the battery. The wind turbine start charging voltage can be modified through the serial communication. The controller has intelligent and modularized design, simple structure, powerful function. The controller use high quality industrial components and excellent production activity, which make the controller is suitable for relatively poor working environment and has reliable performance and service life. 2. Model Description W W S XX A-XX Rated Battery Voltage Advanced Rated Wind Power (e.g. 10 represents the rated wind power is 10ⅹ100=1000W) Solar Power Wind Power Alternative Power eg. WWS 10A-48 Advanced Wind/Solar Hybrid Controller, Battery Voltage is 48V) - 2 -
6 3. Features Intelligently and modularized design, simple structure, powerful function, stable performance. PW M charging with voltage limiting and current limiting, users can set the stop rotation speed of fan precisely. Optional step-up charging module, the module s input impedance and the beginning charge voltage can be adjusted to suit the fixed feature of the different wind turbine. Optional RS232, RS485 interface output TVS lightning protection Using the LCD professionally designed for wind/solar hybrid street light.the LCD can displays all system status and system parameters with intuitive digital and graph. Perfect protection function. 4. Operational Regulations The wind&solar hybrid system connection diagram a is as follows: After wind/solar hybrid generator system and the various components of photovoltaic panels installed and the construction of the external circuit completed, the following order should be carry out to make the connection and operation safely and reliably
7 (1). Open the package and ensure whether the equipment is damaged due to transportation or not. (2). Connect the battery s positive pole to the positive (+) of BATTERY terminal, and connect the battery s negative pole to the negative(-) of BATTERY terminal with copper core cable(section surface 6mm 2 and length 1m). Despite the controller has the battery reversed protection, but reversing battery is still forbidden! (3). Make the wind turbine in brake status and then connect the output line of the wind turbine to the WIND INPUT terminal in back panel. (4). Cover the solar panel with a shelter and the connect the solar panels to the SOLAR INPUT terminal in back panel. (5). Install remote control software, then connect RS232 or 485 interface to computer by data connection. The computer will display the system parameters. (6). Users can check the parameters through the key of LCD. 5. LCD operation and Display Instructions Picture 3, the key of LCD 5.1 Description of the Key: Press any key, LCD backlight lights. The backlight will auto-off while stop pressing the key 10 seconds later. " " key symbolizes increase or next one. In browsing window, press this key to display next parameter. Press this key to look the next parameter which can be modified or increase the value of the current parameter. " " key symbolizes decrease or previous one. In browsing window, press this key to display the previous parameter. In setting window, press this key to look the previous - 4 -
8 parameter which can be modified or decrease the value of the current parameter. "Enter" key symbolizes set or confirm key. In browsing window, press this key to access setting window. In setting window, press this key to save parameter and return to browsing window. "Esc" key symbolizes cancel or manual switch. In setting window, press this key to return to browsing window and do not save the modification. In browsing window, the key is as a manual reset key when the load short-circuit or overload occur. 5.2 Displaying Contents Description LCD screen displays the following picture. 1) symbolizes the wind turbine. 2) symbolizes the day, symbolizes the moon. 3) symbolizes the battery,internal strip graph represents the status of battery power. When the battery is full, 5 power bars in the battery box will show all the instructions. When the battery is over-voltage, the symbol flashing,the flashing will not stop until over-voltage's recovering. 4) is parameters showing. The LCD can displays system parameters with intuitive digital. 5.3 Browsing Parameters and Output Modes Description 1) Turn on the power, the LCD displays browsing window and battery voltage: XX.X V; 2) In browsing window, LCD will circularly display the following parameters by pressing " " key, battery voltage, wind turbine voltage, photoelectric voltage, wind power, PV power, wind turbine current PV current and so on. LCD will display parameters in reverse order by pressing key. (Notes: The controller just uses liquid crystal to display some - 5 -
9 functions but not all of that.) 5. 4 Manual Brake Setting: Press the "Enter" key and "Esc" key simultaneously, LCD displays the symbol that suggests fan is in brake status. Press the "Enter" key and "Esc" key simultaneously in brake status, the symbol will disappear and the brake status is released. In normal situation, the fan can not be set in brake status. 6. Control Software Process one: Software Installation Double-click "WinController.exe" file click "Install" read the agreement of license, click I agree if users agree to the terms and conditions Next Success. (Software installation process is same as general software installation process) Process two : Usage of the software 1. The choice of serial port By default, the serial port is COM1, the 9-needles serial port back in the general desktop is COM1. Connect the RS232 interface of the controller to COM1 serial port of the computer with serial cable(if it is RS485, you need is a RS485 converter RS232, and then connect it to COM1 ). Connect the controller's power supply, then open the software and complete the connection. After the connection, the light in bottom-right corner of the software is green and the status bar up the light displays "Normal". If your computer is not COM1,you can set it by the following step. 1 Firstly, identify your computer's serial port : Right-click "My Computer" "Properties" "Hardware" "Device Manager" "Ports"; check your serial port. 2 Open the software, click "Set" menu "serial port", popup the dialog box and select your serial port ; - 6 -
10 Graphic Displaying Instruction: Chant P-T shows the relationship between power and time, the horizontal axis represents time T, the vertical axis represents power W. Chart U-T shows the relationship between voltage and time, the horizontal axis represents time T, the vertical axis, said power U. Chart P-T / U-T is a polar chart of power -time and voltage-time. The chart shows the date and the time at the same time. The interface of the software instruction Parameters Displaying Instruction: The first column displays battery's parameters, followed by current, voltage, power, quantity of electricity. The second column displays solar energy's parameters, followed by current, voltage, power, quantity of electricity. The third column displays the wind turbine's parameters, followed by current, voltage, power, quantity of electricity. The bottom- right corner shows the light and the speed of fan. The light shows yellow and character No Signal when there is no signal, green and character Normal when there is signal, red and character Unload when controller is unloading, red and character Low Battery when battery is low voltage. The interface displays the speed of fan when the system works well. Menu Bar Instruction: Viewing, saving and deleting of power - 7 -
11 (1) "File" "The month consumption" (to see the electricity of the month ) (2) "File" " Inquire electricity" (to see the previous electricity) (3) "File" "Save electricity" (to save the electricity of the month ) (4) "File" "Delete the electricity of the month " Set menu (1)"set" menu "Serial port" menu, select the port (2)"set" menu Background menu, set the company name and main form. (3)"set" menu "scale" menu, set the scale of P-T curve and U-T curve (4) "set" menu "speed of fan"menu, select "fan speed showing" or "no fan speed showing" (5) "set" menu "system selection", select 12V system or 24V system in "controller system" bar and select Chinese-English or English LCD display interface in "LCD interface". View menu Users can select which curve will be displayed in the pull-down menu of "View" menu. There are battery curve, solar curve, wind energy curve or all three showing at the same time. Parameter menu (1) "Parameter" menu "Set" menu.(users can set or modify the unload voltage point, unload current point, RMP of fan stop, input impedance range and initial charging voltage. Password is needed when modify the parameters and factory default is ( (2) "Parameter" menu "Control" menu.(it can control the wind turbine). Notes: Password is needed when modify the parameters. Enter the password and click "OK" twice, when there is "set successfully", setting parameters is succeed, otherwise it should be reset. 7. Parameters Model Rated Battery Voltage Rated Wind Turbine Voltage Rated Wind Turbine Maximum Power WWS10A-48 48V 56VDC 1000W Input Impedance Range (factory default) 2~30Ω adjustable(6ω ) Rated Wind Turbine Maximum Input current 0~40A - 8 -
12 Rated Wind Turbine Maximum instantaneous Input current Wind Turbine Charge Voltage( factory default) Unload Voltage ( factory default) Unload Current ( factory default) Wind Turbine over Speed( factory default) Rated PV Maximum Power Rated PV Rated Voltage PV maximum charge Current 2000W Continuous Adjustable(8V) 52v~60V adjustable (54V) 0~20A adjustable (18A) 0~600rmp adjustable, recover automaticlly 10 minutes later (500rmp) 600W 68V 10A -5mv/ /2V(Over-Discharge Protection, over-discharge recovery T e m p e r a t u r e C o m p e n s a t i o n voltage unload voltage compensation) Control Mode PW M Display Mode Display Parameters Communication Interface Module Range of working Temperature &Humidity Quiescent Current Protection Type LCD Battery Voltage, Wind Turbine Voltage, PV Voltage, Wind Turbine Current, PV Current, Wind Turbine Power, PV Power.Etc RS-232C (RS485 is selection) -20~+55 /35~85%RH(Without Condensation) 20±2 ma (100mA if the interface is RS485) Solar cells reverse charging, solar cells anti-reverse, battery over charge, battery over-discharge, battery anti-reverse, Overloading, lightning protecting, wind turbine current limitting, wind turbine automatic brake and manual brake
13 8. Abnormal phenomenon and treatment Phenomenon Description The symbol without charge or flashing, Battery is over-voltage, check battery voltage, and the cable is connected or not, reconnect all components; discharge a) First of all, "Parameter" menu "Control" menu through LCD controller always displays "brake (BRAKE)", and the manual can not cancel the software, to see if set to "brake", cancel the brake status. b) Brake state is usually caused by over-speed of wind turbine. It will automatically return to normal after 10 minutes under normal circumstances. c)if not the above, first disconnect the fan and controller, and then disconnect the battery and controller. After a few minutes to start re-wiring work, observing whether it has returned to normal. If the phenomenon do not meet the description or can not return to normal, please contact our service department or salesman to repair or replace
Advanced Wind/Solar Hybrid Controller. Model: WWS10A-48 Version 1.0
Advanced Wind/Solar Hybrid Controller Model: WWS10A-48 Version 1.0 Notes 1-Really appreicate purchasing our controller. Pls read manual with care before installation and keep it properly 2-Installation
User s Manual. Wind/Solar Hybrid Controller NV-SW10C48. Please Read This User Manual Carefully Prior to Installation and. Operation of This Product.
User s Manual Wind/Solar Hybrid Controller NV-SW10C48 Please Read This User Manual Carefully Prior to Installation and Operation of This Product. 2012 V1.0 Notices 1) Battery reverse-connection is forbidden.
How To Control A Battery Cell Phone With A Battery Power Control System
Wind/Solar Hybrid Street Light Controller User Manual Model: HY-WSC04-12AWM, HY-WSC04-12/24AWM, HY-WSC06-24AWM, HY-WSC06-48AWM 1. Product Introduction The wind/solar hybrid street light controller is an
2 Installation Explanation
Intelligent Solar Charge Controller Solar30 User s Manual Please read this instruction carefully before using it. SOLAR30 12V/24V AUTO WORK 1 Product introduction This controller is a kind of intelligent
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
INSTRUCTION MANUAL OVERVIEW. ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.
INSTRUCTION MANUAL ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series. OVERVIEW The digital Remote Meter displays system operating
BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product
Wind/solar hybrid controller instructions
Wind/solar hybrid controller Key Features: 1. U.S. imports of products based on expert-level micro controller and dedicated control software; 2. With battery overcharge over discharge reverse protection;tan
PSC-A5 Solar Charge Controller Manual
( 5A, 12V/24V Output, Double Mode ) 1. Introduction: This controller is suitable for 12V and 24V solar photovoltaic system. The charge and discharge current is 5A. The maximum solar panel for 12V system
Solar Controller / Battery Charger User s Manual
Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
TruPower-Portable-500W. Solar Starter kit
TruPower-Portable-500W Solar Starter kit This Solar starter kit is an easy to use solar power supply system that is the complete solution for all your solar power needs. It is a solar generator that converts
User s Manual for Fingerprint Door Control Software
User s Manual for Fingerprint Door Control Software Foreword The naissance of F7 indicated that fingerprint reader enters into professional door control domain. That s why we developed this software to
Point of view HDMI Smart TV dongle Mini RF Keyboard
Point of view HDMI Smart TV dongle Mini RF Keyboard English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1. HDMI TV dongle... 3 1.1. Product display... 3 1.2. Instructions
Renewable Energy Monitor User Manual And Software Reference Guide. [email protected] (979) 703-1925
Renewable Energy Monitor User Manual And Software Reference Guide [email protected] (979) 703-1925 1 Introducing the Horizon Renewable Energy Monitor The Renewable Energy Monitor is an educational
Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software
Manual EN Appendix Blue Solar PWM Pro setup and monitoring software EN Appendix Contents 1. Region and language settings 2 2. Download the software 2 3. UnRAR the software 2 4. Install the software 3
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
Operation Manual For NDJ-8S Digital Rotary Viscometer
Operation Manual For NDJ-8S Digital Rotary Viscometer 1 Contents 1. General... 2 2. Main technical data... 2 3. Working principle... 2 4. Installation... 3 5. Operation procedures... 4 6. Precautions...
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
Battery Power Inverters
Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.1 Important Safety Instructions Please save these instructions.
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
SOLAR POWER - THE NEW WAY TO RV!
IMPORTANT! - YOU'RE SOLAR READY SOLAR POWER - THE NEW WAY TO RV! Your RV is PRE-WIRED for SOLAR POWER! Benefits of Solar Zamp Solar Portable Solar Kit Maximize Battery Life Electrical Independence Green,
DAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Speedlink software will run on Windows NT, Windows 7, and Windows 8; it will run on both 32 byte and 64 byte versions of Windows.
Guide to the Speedlink software and drivers. Status Instruments has a range of process control equipment that can be configured using the Speedlink software. Some equipment will connect directly to a Windows
User s Manual. Management Software for Inverter
WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...
User Manual WatchPower
User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
INSTALLATION AND OPERATION MANUAL
ECO-WORTHY INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL www.eco-worthy.com ECO-WORTHY Solar tracker ECO-WORTHY 400 Solar Tracker Owner s Manual Manual User Installation instructions
"USB Serial Adapter" User Manual
"USB Serial Adapter" User Manual V1.00 Table of Contents 1. Introduction................................2 2. Device Specifications........................2 2.1. Environmental Conditions......................2
JORAM 3.7 Administration & Monitoring Tool
JORAM 3.7 Administration & Monitoring Tool User Guide Author: Alexander Fedorowicz Date: October 26, 2003 Overview The JORAM Administration & Monitoring Tool (jamt) is a graphical user interface which
IDDERO HOME SERVER. Quick start guide. www.iddero.com 150302-02
IDDERO HOME SERVER Quick start guide www.iddero.com 150302-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 IDDERO CONFIGURATION SOFTWARE... 3 2.1 Installation and First Steps...3 3 IDDERO HOME SERVER CONFIGURATION...
Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers
Technical Note Freedom/Fleet Power 512-0084-01-01 Rev 1 Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Overview This document is a guide for troubleshooting inverters, battery chargers,
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It
USING PEUGEOT PLANET SYSTEM. Peugeot Planet System User Guide AP/TAVG/MMXP/MUX
Peugeot Planet System User Guide AP/TAVG/MMXP/MUX AP/TAVG/MMXP/MUX Page 1 05/11/2004 SUMMARY 1 Preamble... 3 2 Using your PC... 4 2.1 Turning the PC on... 4 2.2 Turning the PC off... 5 2.3 How to optimize
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Communication bridge Xcom-MS User Manual
Communication bridge User Manual Copyright 2011 Studer Innotec SA - V1.0.1 Communication bridge : User Manual V1.0.1 Copyright 2011 Studer Innotec SA About the software This document applies to the software
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:
the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the
Owner s Manual 900.4. 4 channel amplifier
Owner s Manual 900.4 4 channel amplifier THANK YOU Limited Warranty: for purchasing RE AUDIO Bluetooth amplifiers BT-900.4. With almost no sacrifice on sound quality, BT-900.4 easily plays the music from
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
SPL 2-00/-01 OPERATION INSTRUCTIONS
SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement
LITHIUM BALANCE CHARGER
LITHIUM BALANCE CHARGER A Microprocessor controlled, high-performance charger for NiCd/NiMH/LiPo/Pb batteries with an integral individual voltage balancer (LiPo only) Operating Manual Please read this
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
Lab 3 - DC Circuits and Ohm s Law
Lab 3 DC Circuits and Ohm s Law L3-1 Name Date Partners Lab 3 - DC Circuits and Ohm s Law OBJECTIES To learn to apply the concept of potential difference (voltage) to explain the action of a battery in
NVMS-1200. User Manual
NVMS-1200 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Install and Uninstall... 1 1.2.1 Install the Software... 1 2 Login Software... 3 2.1 Login... 3 2.2 Control Panel Instruction...
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Skyworth LCD Video Wall Controller User Manual Please read the user guide book carefully before using this product
Skyworth LCD Video Wall Controller User Manual Please read the user guide book carefully before using this product 1 Contents 1. Features 2. Specifications 3. Control System Illustration 4. Operation 2
DIRECT INTERNET DATA. User s Guide
DIRECT INTERNET DATA User s Guide Iridium Satellite LLC Rev. 2; June 15, 2001 DIRECT INTERNET DATA ------------------------------------------------------------------------------------- TABLE OF CONTENTS
Alber Training and Education Product Tutorial. Battery Monitor Data Manager Software (BMDM)
Alber Training and Education Product Tutorial Battery Monitor Data Manager Software (BMDM) 1 Tutorial Topics Introduction System Computers Battery Monitor Data Manager Software Overview String Status Screen
PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.
PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering
magnetronic GmbH Kreuzhofstr. 10 81476 München Tel.: 089/7553670 Fax: 089/7556059 Email: [email protected] Battery control system DCC 6000
magnetronic GmbH Kreuzhofstr. 10 81476 München Tel.: 089/7553670 Fax: 089/7556059 Email: [email protected] Battery control system DCC 6000 Description and Operating Instructions Dear customer, You
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay
SoftRAID 5 QUICK START GUIDE for OWC ThunderBay TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.2 FEATURES 1.3 ABOUT THIS MANUAL SYSTEM SETUP...2 2.1 GETTING STARTED 2.2 INITIALIZING,
AXIS 205 Network Camera Quick Installation Guide
AXIS 205 Quick Installation Guide Page 1 of 6 AXIS 205 Network Camera Quick Installation Guide Focus Ring Status Indicator (surrounding the focus ring) Serial number Network Indicator Control Button Power
Terminal and Dimension
Ethernet Extender Model Number: SJ-L-DSL Complete Installation Guide Product Description Product Features SJ-L-DSL is network signal extension device, which consists of remote unit and local unit. It can
OCSM Series. High Resolution Digital Crane Scale. User Guide
OCSM Series High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 3 5. Display & Keys... 3 Scale & Remote Keys... 3 Indicators... 4 Message...
22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA
Instruction Manual 22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA OPERATION / INSTALLATION MANUAL Thank you for using this product. Please read this manual carefully before use, Please keep this instruction
PG DRIVES TECHNOLOGY R-NET PROGRAMMER R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1
R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1 PG Drives Technology 2009 All rights reserved. This manual is furnished under copyright and may only be used in accordance with
How To Set Up A Smart Card Programmer With Titan 2.2.2 (Titan) And Titan 2.3 (Tok) (Tonga) (Powerbook) (Smart Card) (Programmer) (S
Smart Card Programmer TS0870P: Installation Guide Overview The TS0870P Smart Card Programmer programs user cards for use with the TS0870 Smart Card Reader. Using TITAN management software, cards are programmed
Work with Arduino Hardware
1 Work with Arduino Hardware Install Support for Arduino Hardware on page 1-2 Open Block Libraries for Arduino Hardware on page 1-9 Run Model on Arduino Hardware on page 1-12 Tune and Monitor Models Running
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
DSM155 Digital LED Light Meter User s Manual DSM155
DSM155 Digital LED Light Meter User s Manual DSM155 CONTENTS TABLE OF CONTENTS......3 LIMITED WARRANTY AND LIMITATION OF LIABILITY......3 Out of Box....3 Accessories....3 Safety Information....3 Certification....5
OCS-S High Resolution Digital Crane Scale
OCS-S High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 2 5. Dimension & Weight... 3 6. Display & Keys... 4 Scale Keys... 4 Indicators...
ABB solar inverters. User s manual ABB Remote monitoring portal
ABB solar inverters User s manual ABB Remote monitoring portal List of related manuals Title ABB Remote monitoring portal User s manual NETA-01 Ethernet adapter module User s manual Code (English) 3AUA0000098904
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
SHENZHEN JUNSI ELECTRONIC CO.,LTD
Cell Voltage Monitor&Logger USER S MANUAL SHENZHEN JUNSI ELECTRONIC CO.,LTD Thank you for purchasing the. Please read the entire User s Manual completely and attentively as it contains a wide variety of
COLOR TFT LCD MONITOR. User Manual
COLOR TFT LCD MONITOR User Manual GENERAL INFORMATION Thank you for choosing our TFT LCD(liquid crystal display) monitor. This product employs integrate circuits, low power consumption, and no radiation
User Manual for CH-PFC76810
AA Portable Power Corp www.batteryspace.com, Email: [email protected] User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those
Hydras 3 LT Quick Start
Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright 2005-2013 Pico Technology Limited. All rights reserved.
USB TC-08 Temperature Logger User's Guide USB TC-08 User's Guide I Contents 1 Introduction...1...1 1 Overview...1 2 Leg al information...2 3 Safety warning...3 4 Company details 2 Getting Started...4...4
2GB MP3 Player USER GUIDE
DO NOT FORMAT UNIT under FAT. 2GB MP3 Player USER GUIDE Jazwares, Inc. 2010 CONTENTS Please read the instructions along with the MP3 Player carefully before you use it, so that you can operate it conveniently.
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
User Manual Software for DSL Digital Speed Switch
User Manual Software for DSL Digital Speed Switch Software version from 1.0.1 Baumer Hübner GmbH Max-Dohrn-Str. 2+4 D-10589 Berlin Phone +49 (0)30 690 03-0 Fax +49 (0)30 690 03-104 [email protected]
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
Charge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
Advanced Central Monitoring. User Guide
Advanced Central Monitoring User Guide TABLE OF CONTENTS: 1. General... 3 2. Installation... 4 2.1 Software Installation... 4 2.2 Physical Installation... 4 3. First Start... 6 4. Adding Floor Plans and
Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in
Samba PLC+HMI SM35-J-RA22 SM43-J-RA22 Installation Guide 12 Digital Inputs, including 1 HSC/Shaft-encoder Inputs, 2 Analog Inputs, 2 PT100/TC inputs 8 Relay Outputs 2 Analog Outputs General Description
Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts
Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board
SoundLAB Software Download Software from the Bogen website: www.bogen.com/software
SPLM DIGITAL SOUND PRESSURE LEVEL METER SoundLAB Software INSTALLATION & INSTRUCTION MANUAL Download Software from the Bogen website: www.bogen.com/software Specifications are subject to change without
OPLC Installation Guide
Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
