Central System of Medical Gases
|
|
|
- Jordan Gilmore
- 9 years ago
- Views:
Transcription
1 Central System of Medical Gases
2 Medicop Medical equipment Content Dear clients, With present brochure we would like to introduce our newest system for central medical gas supply, which complies with demands of standards EN ISO or HTM and includes the most advanced technical solutions. In this brochure you will find the most important benefits which the system offers, while detailed technical data and drawings are available in our Technical Catalogue. Our entire production program of medical equipment includes the following product-groups: Central System of Medical Gases Medical Suction Units Oxygen Therapy Devices Bed Head Units Medical Supporting Equipment CENTRAL SUPERVISION OF MEDICAL GAS SYSTEM Observe the status of your gas system from anywhere in the world MEDICAL GAS MANIFOLDS Perfect function, simple control MEDICAL GAS PLANTS Save huge amount of energy with an appropriate gas plant CONTROL-CLOSING BOXES Keep all gases in your building under perfect control TERMINAL UNITS Simple, reliable, and delivered immediately PIPELINE SYSTEM Connect perfect components with perfect network 2 3
3 CENTRAL SUPERVISION OF MEDICAL GAS SYSTEM "Observe the status of your gas system from anywhere in the world" Our experiences of over 30 years with production and installation of medical gas systems and our professional staff are the basic reasons why we are able to offer perfect and complete medical gases system to any healthcare institution, as well as the professional consulting in this field. One of the main advantages of our system is new Supervision System with CAN-BUS technology, which enables collection of all conditions of gases in one place and distribution of this information worldwide via internet, or mobile phones. There are two supervision models available; one with central LED display and one as software which can be installed to PC. Working with MEDICOP Supervision System will offer you great pleasure, because of the following reasons: SUPERVISION AND MANAGEMENT the status of all medical gases and their characteristics can be seen in one place and therefore action in case of malfunction or maintenance-demand can be punctual. ACCURATE CALCULATION OF COSTS the system enables overview of gas consumption for separate sectors in a building and is therefore it a great tool for costs-calculation of medical gases. CAN-BUS TECHNOLOGY enables fast functioning of system, reliable connection, safe network and compatibility for integration in other networking systems (SAP, Navision, etc.). CONTROL FROM ANYWHERE the access into supervision system can be remote via internet and it is also possible that the system submits essential warnings as text-messages to the supervisor s mobile phone. SCHEDULING OF MAINTENANCE warning messages for maintenance and service are displayed prior the work is required and therefore the supervisor can be always prepared for such action. SIMPLE UPGRADES when additional components are installed in an existing medical gas system, it is possible and very easy to include their status into the existing central supervision system. ASSISTANCE NEEDED? PC version of supervision system also enables the manufacturer to view the status of gases from his location and to offer professional assistance in case of malfunction, or maintenance-demand. LED display for overview of plants/manifold status and area control boxes status PC software for overview and management of complete medical gas system 4 5
4 MEDICAL GAS MANIFOLDS "Perfect function, simple control" Gas manifolds are designed to supply the pipeline system with sufficient quantity of gas by cylinders and/or tanks. The typical manifold for medical gases (O 2, N 2 O, CO 2, or medical AIR) according to EN ISO or HTM consists normally of two-side cylinder supply with automatic change over between empty and full side, and additional third source for emergency supply. For oxygen usually the liquid source is being used as primary supply, while two-side cylinder supply is being used for reserve. The design of Medicop manifolds enables very reliable function and offers for user variable advantages, for example: MULTIFUNCTION we have models available for small clinics with only one terminal unit for gas and up to the biggest health care institutions with thousands of terminal units. EASY HANDLING special conical shape of cylinder connection and a handle fixed on all connecting points enable that all empty cylinders are changed without using any tool. COMPATIBILITY FOR EVERYBODY the valves for cylinder connections are available in all standards for high pressure equipment, which are being user around the world. SAFETY, ALWAYS IN OUR MIND there are special safety valves installed for each source of high pressure, as well as separate safety valve for line pressure. INTEGRATED DIGITAL DISPLAY all information about manifold status (pressure level of each source, line pressure level) and alarm are being monitored on one display, which enables also forwarding of collected information to the central supervision of medical gases. EASY MAINTENANCE filters and other waste components are placed in such position that they are very easily accessible and therefore the regular service can be done in very short time. FLOW IS NEVER INTERRUPTED double line-pressure regulators and NIST inlets make it possible, that the pipeline is supplied with required quantity of gas even during maintenance or service of any component of a manifold. 50 m 3 /h Capacity 80 m 3 /h 180 m 3 /h Number of cylinders 1 48 analogue by gauges, Display of status/alarm digital with central LCD Oxygen, Nitrous Oxide, Type of Gas Carbon Dioxide, Air, Nitrogen, Helium EN ISO Available standards or HTM
5 MEDICAL GAS PLANTS VACUUM, AGSS PLANTS Energy saving: the most important function for a gas plant is that the operation and capacity of all components are synchronized, because in that way the consumption of energy is as low as possible. Therefore we offer special control boards for operation of compressors, pumps and filtration systems. Available capacity of air plant lit/min Available capacity of vacuum plant m 3 /h Available capacity of AGSS plant m 3 /h Available standards EN ISO or HTM AIR PLANT Save huge amount of energy with an appropriate gas plant. We offer medical gas plants for compressed air, vacuum and anesthetic gas scavenging. Compressed air can be used either as medical air, or as energy source for driving surgical tools. The typical plant according to EN ISO or HTM usually consists of 2 or 3 compressors/pumps, board for their control, pressure vessel, filtration system and pressure control panel. The design of Medicop plants enables very reliable functions and offers variable advantages for user, for example: LOW NOISE LEVEL SIMPLE TO INSTALL, EASY TO OPERATE OPTIMIZED PRESSURE CONTROL condensation, bacteria and mould growth. the use of a low speed fan and modern tech- we deliver all components of plant preas- pressure control panel can be combined for A dual cleaning stage includes activated niques of vibro-acoustic optimization has sembled and ready for operation. On site it medical air and surgical air, or separate for carbon to eliminate hydrocarbons (oil vapor, resulted in extremely low noise levels. is just necessary to connect all components each air source. Double regulators with by- smells). A catalyst then converts CO into CO 2. and start up the plant. pass are installed for each source to assure A particle filter at the exit removes particles continuous supply in case of service or main- which may have been introduced in the des- PERFECT OVERVIEW OF STATUS tenance of any component. iccant stages down to 0.01 micron. the control board for operation of compressors/pumps and filtration system provide PERFECT AIR QUALITY HIGH EFFICIENCY COMPRESSORS all possible information about the status the water separator and coalescing filters we use compressors/pumps, which are of plants, like current pressure level, over- remove free water and particles down to designed and manufactured to meet the heating notice, fault of separate component, 0.01 micron and eliminate oil droplets down industry s expectations of the highest qual- counter of working hours, etc. It is possible to 0.01 ppm. A heatless desiccant dryer ity standards. They have been designed to connect all information to the central gas reduces moisture content to a pressure to be service friendly with direct and easy supervision. dew point of -40 C, removing any risk of access to all components. Wear out of parts is reduced to a minimum. 8 9
6 CONTROL-CLOSING BOXES "Keep all gases in your building under perfect control" Control boxes are installed in individual floors and allow status control of medical gases throughout the building. Medicop boxes include all features required by standards EN ISO , HTM like monitoring of pressure, possibility to close the flow, alarm for too high, or too low pressure, emergency supply inlet, but their design provides following advantages for the user: FASCINATING DESIGN buttons TAB and DOWN the user can check MEASURING OF TEMPERATURE PHYSICAL INTERRUPTION OF FLOW front panel is made of dark tempered glass. and manage all available menus of the soft- with installed ambient temperature-sensor it with special plates attached (red-stop), All controls and monitored parameters are ware. The settings in software are allowed is possible to set an alarm for too high tem- (green-go) it is possible to close the flow integrated on that very panel. only to authorized personal and the access is perature of gas. physically and then carry out a professional AUTOMATIC ADJUSTABLE DIGITAL DISPLAY secured by PIN code. MEASURING OF CONSUMPTION HISTORY OBSERVATION all events for each installed gas are being leakage test. the field of display is automatically adjust- with an installed flow-sensor a user can stored in a software of display. A user can able regarding the number of gases installed obtain information about how much gas was therefore observe the history of all errors of in a box. It is possible to install 1 to 5 dif- spent in a certain period of time in a certain pressure level, temperature errors, inappro- ferent gases in a single box. With push medical department. priate opening of doors, etc. For each event its start and end are being stored. INTEGRATION WITH CENTRAL GAS SUPERVISION there are available CAN-BUS contacts and potential-free contacts to integrate information of control box with central gas supervision system. Number of gases 1 5 Installation Monitoring/alarm Size of connecting pipe Additional equipment Available standards surface-mounted, sunken-mounted analogue by gauges, or digital by LCD 8 22 mm flow-sensor, temperature-sensor, back-up battery for display valve sensor door sensor EN ISO or HTM
7 TERMINAL UNITS "Simple, reliable, and delivered immediately" Terminal unit for medical gases is the product we have the most experiences with. We started to produce and install those products 25 years ago. Continuous improvements during the years made our terminal units to be among the best in the world nowadays. There are several reasons, why you should choose Medicop terminal unit for medical gases: SMOOTH CONNECTION COMPATIBLE FOR EVERYBODY EASY INSTALLATION ADVANCED CLEANNESS the connection and disconnection run incred- the design enables installation of outlet as we deliver the outlets preassembled, so that as an option we offer outlets with sinter filter ibly smooth, both the connecting-positions surface-mounted, flush-mounted, hose- on site it is just necessary to install them in to assure supply of cleaner gas for patients. (parking and final) are very markedly, which means it is not necessary to hold the medical mounted, or BHU-mounted. On client s request we offer special constructions of appropriate boxes and connect them to the gas source. EXTREMELY FAST DELIVERY device by hand when being disconnected, it will remain in parking-position itself. outlets in order to be compatible with any model of bed head units, or ceiling pendants. ADVANCED SAFETY we keep large quantity of all models on stock. From Medicop you can get medical the body of outlet is fixed to the gas source gas outlets in the shortest time. LONG SHELF LIFE by safety nut. This prevents non-competent outlets are made of special material personnel to connect the outlet to the wrong (Polyamide), which is very resistant against gas source. The releasing rings are gas- wear out. Our outlets installed 25 years ago specific not only because of different label are therefore still in function. but they are also of different shape, so it is absolutely impossible to mix them. Available standards Way of installation Gases DIN (German), BS (British), SS (Swedish) surface wall-mounted, flush wall-mounted, BHU/pendant mounted, hose-mounted, Y-model oxygen, N 2 O, medical air, surgical air, vacuum, CO 2, nitrogen, AGSS, mixture O 2 /N 2 O, AGSS 12 13
8 PIPELINE SYSTEM "Connect perfect components with perfect network" High quality components of medical gas system are worthless, if they are not connected by professionally installed pipeline system. MEDICOP has more than 30 years of experiences with installations and maintenance of medical gas systems and therefore we can assure to our clients professional service for this work, either by our own installation teams, or trained partners. MEDICAL COPPER PIPES we use only specially degreased copper ACCOMMODATION FOR SPECIAL BUILDINGS SUITABLE PRESSURE & FLOW AT EACH SECTION ASSISTANCE FOR CALCULATIONS we are pleased to offer our clients also the pipes with certificate for medical gases. we can provide special carriers and support- the in-line pressure regulators can be pro- professional consulting for the new medical FULL ASSORTMENT OF FITTINGS ers for pipes in case the regular models are not appropriate regarding the situation on a vided of different capacities in order to assure appropriate quantity of gas at each gas systems, or their upgrades in order to chose the appropriate components of the no matter what shape and size your facility building. sector of the building. system regarding to capacity, power, pipe- is, we can provide appropriate fittings, which will make the work for installers easy and fast. SECURED CONTROL OVER PIPELINE SYSTEM DON T BELIEVE PROMISES, BELIEVE TEST RESULTS line sizes, etc. the shut-off valves can be provided either each component of gas system as well as lockable, or un-lockable models. The the complete system are tested according advantage of lockable model is to prevent to all requirements of relevant standards incompetent persons to shut down/on the before the system is handed over to the user. gas flow. Sizes of copper pipes and fitting 8 mm 76 mm Sizes of shut-off valves 3/8" 3" lockable type, Models of shut-off valves un-lockable type 50 Nm 3 /h Capacity of in-line pressure regulators 100 Nm 3 /h 180 Nm 3 /h 14 15
9 MEDICOP medicinska oprema d.o.o. Obrtna 43 (p.p. 161) SI Murska Sobota, Slovenia T: F: [email protected] All products comply with: MDD 93/42/EEC and 2007/47/EEC
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas
The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO
The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3
ETC -SV. Class 0 oil-free compressed air through catalysis
Innovation QUALITy Reliability Worldwide ETC -SV Class 0 oil-free compressed air through catalysis The way to oil-free compressed air The ETC operating principle Through the process of catalytic oxidation,
Validation of process gas systems
Validation of Process Gas Systems By Jeff Hargroves Alza Corporation Validation of process gas systems involve documenting the expected system behavior, and verifying that the system performs as expected.
Atlas Copco Quality Air Solutions. Compressed Air Filters
Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational
ThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED
HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed
TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System
TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured
Compressed Air Filters
Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003 Knowing the functions of the anesthetic delivery system
10 tips for getting more reliability from your air-conditioning system [reliability]
10 tips for getting more reliability from your air-conditioning system [reliability] A guide for installers, specifiers, contractors and architects February 2010 10 tips for getting more reliability from
OHIO MEDICAL CORPORATION. Medical Gas Outlets. Installation and Maintenance Manual
OHIO MEDICAL CORPORATION Medical Gas Outlets Installation and Maintenance Manual P/N PAGE 2 SQUIRE-COGSWELL COMPANY WAS FORMED IN 1916 AS A SUPPLIER OF RAILWAYAND FOUNDRY EQUIPMENT IN CHICAGO. IT CONTINUED
Recharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
Pro Dry Heatless dessiccant compressed air dryers
Pro Dry Heatless dessiccant compressed air dryers Features Each Pro Dry unit has been designed to suit a multitude of requirements and is suitable for installation in many countries. The Pro Dry range
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
Pipeline. Medical Gas Pipeline Products
Pipeline Medical Gas Pipeline Products w w w. a m i c o. c o m The Amico Group Manufactures the Building Blocks of the Hospital Architectural Beds Lights Interiors Accessories Patient Care Diagnostic OR
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
Basic Hydraulics and Pneumatics
Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
Desiccant Air Dryers Heatless, Heated and Heated Blower
Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Dryers... Desiccant Our reliable high strength, non-acidic desiccant provides maximum performance and is easily stored and handled. Environmentally
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com
PNEUMATIC PRODUCTS pneumaticproducts-spx.com Externally Heated Desiccant Compressed Air Dryers PHD Series PHD Series Dryers Reduce Purge Air Energy Costs PHD Series Dryers Reduce Purge Air Energy Costs
HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer
Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators
Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
Description TERMINAL UNIT AFNOR NF S 90-116
PF-01US-00O2 PF-02AU-00O2 PL-23A0-10O2 TERMINAL UNIT AFNOR NF S 90-116 UNI base block with welding nut for Oxygen Outlet AFNOR NF S 90-116 for Oxygen Coloured ring for oxygen Complete terminal units AFNOR
ThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems
CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators
Atlas Copco On-site Industrial Gases Nitrogen & Oxygen Generators A secure supply of nitrogen and oxygen Whether your company is specialized in chemical manufacturing, electronics, laser cutting or food
ON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
Refrigeration Compressed Air Dryer Buran Ultrapulse
Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC
RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side
Facility Operations Physical Safety Guidance Document
Facility Operations Physical Safety Guidance Document Title: Guide on Pipe Identification Standards (ASME A13.1-1996) Original Date: December 18, 2000 Section: 4.0 Facility Operations Revised Date: Number:
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
NITROX // safer diving
NITROX // safer diving Always available, easy to use and safe for daily use: NITROX diving gas offers professional divers, yacht owners and offshore facilities the highest level of convenience and independence
OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br
OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter
GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)
GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS Argotec Liquid Argon Gas Extinguishing Technology (LAR) INNOVATION modern technologie snuffed out cold Argotec liquid argon gas ex tinguishing
SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES
SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES Filippo Turra Product Manager Cooling Technology INTRODUCTION
POLICY BULLETIN Tecumseh Compressor Company Compressor Group
to Bulk Milk Coolers and Other System Page 1 of 5 Overall reliability can be enhanced if there exists a complete understanding of the features, system design, installation requirements, processing, charging
DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING
PREMIUM HIGH-PRESSURE DRYING HIGH QUALITY COMPRESSED AIR FROM BEKO The quality of your compressed air. RELIABLE The highest level of operational reliability is guaranteed with every product that BEKO manufactures.
A/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
REMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
Technical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.
Postbus 9058 6070 AB Swalmen (NL) Akzo Nobel Car Refinishes S.L./Coatings S.L. Att. Mr. Cesar Franch Tel. +31(0)77-7676276 Fax +31(0)77-7676286 e.mail [email protected] website www.ants-tech.nl [email protected]
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00
SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!
Compliant Healthcare Technologies, LLC NFPA 99, 2012 Changes November 13, 2013! The standard is now a CODE!! The NFPA 99 has now been upgraded from a Standard to a Code. This will put it in the same light
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Guide to good leak testing
Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant
CONDENSATE MANAGEMENT
CONDENSATE MANAGEMENT Innovative and integrated Systems Solutions Filtration Solutions from Donaldson Donaldson is a leading global manufacturer of filtration systems. The company, which was founded in
SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater
SALES SPECIFICATION SC7640 Auto/Manual High Resolution Sputter Coater Document Number SS-SC7640 Issue 1 (01/02) Disclaimer The components and packages described in this document are mutually compatible
ultrafilter HEATLESS HL Adsorption Dryer
The EW product line of HeatLess adsorption dryers Why drying compressed air? Compressed air is used in almost all areas of industrial manufacturing as a source of energy or processing. Compressed air needs
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Online Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration
INNOVATIVE COMPRESSED AIR SOLUTIONS DESICCANT AIR DRYERS 90-8000 scfm ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration 2100ZHA RELIABLE PERFORMANCE INNOVATIVE DESIGN Before
Why use Tigerloop in fuel heating systems?
The Original Oil De-aerator Why use Tigerloop in fuel heating systems? Reliability New products are continually being developed in the modern oil heating industry in order to satisfy new laws and regulations
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice
Bulk Storage the OIL SAFE Way OIL SAFE Bulk Systems are the most feature rich and highest quality lubricant storage and dispensing systems available. Fully Modular and ships ASSEMBLED Three System Types
Chromatograph Maintenance and Troubleshooting Class # 5050
Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction
2007 Medical Gas System Cylinder Storage, Piping & Alarms Reminder List
2007 Medical Gas System Cylinder Storage, Piping & Alarms Reminder List Applicable Codes and Standards CBC 2007, CEC 2007, CFC 2007 NFPA 55 2005, NFPA 99 2005 I. APPLICABILITY 1. The design, installation
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.
Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute
T a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
ANNEX 17 DRAFT AMENDMENTS TO SOLAS REGULATIONS II-2/4 AND II-2/16. Part B Prevention of fire and explosion
Annex 17, page 1 ANNEX 17 DRAFT AMENDMENTS TO SOLAS REGULATIONS II-2/4 AND II-2/16 Part B Prevention of fire and explosion Regulation 4 Probability of ignition 1 The existing paragraph 5.5 is replaced
Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF
Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS WWW.LANCOM4.COM
PORTABLE FLUE GAS MONITORING WWW.LANCOM4.COM i CO low CO high O 2 NO NO2 NOx CO2 H2S SO2 CxHy QUALITY CUSTOMER SOLUTIONS AMETEK LAND HAS BEEN BUILDING PRECISION MEASURING EQUIPMENT SINCE 1947. WE ARE SPECIALISTS
OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual
OHIO MEDICAL CORPORATION Medical Gas Panel Installation and Maintenance Manual P/N 255105 (Rev.5) 08/2005 P/N 255105 (Rev.5) 08/2005 PAGE 2 OHIO MEDICAL CORPORATION PAGE 3 1.0 User Responsibilities The
Refrigeration Basics 101. By: Eric Nelson
Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs
Health Choice Enterprises ASSE Medical Gas Course
Course Description This course is divided into the following Two Sections The main focus of this 32 hour Medical Gas Course is to provide training and testing regarding the operation, application and code
2013 Medical Gas Cylinder Storage, Piping & Alarms System Reminder List
2013 Medical Gas Cylinder Storage, Piping & Alarms System Reminder List Applicable Codes and Standards CBC 2013, CEC 2013, CFC 2013 NFPA 55 2013, NFPA 99 2012 I. APPLICABILITY 1. The design, installation
Safe Method: Gas Safety in Catering Establishments
Safe Method: Gas Safety in Catering Establishments Safety Point Why? What do you do? Gas equipment and services must only be installed, maintained and repaired by a Gas Safe registered installer. Check
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
Electronic Diesel Control EDC 16
Service. Self-Study Programme 304 Electronic Diesel Control EDC 16 Design and Function The new EDC 16 engine management system from Bosch has its debut in the V10-TDI- and R5-TDI-engines. Increasing demands
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2
Instruction Manual Dew Point Tester The CVS Dew Point Tester is a chilled mirror apparatus, which operates by attaining the conditions necessary by the definition of dew point. When a gas is cooled out
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
Refrigeration Air Dryers ADQ. Capacity: 21-4200 m 3 /h
Refrigeration Air Dryers Capacity: 21-4200 m 3 /h Water Contamination in Compressed Air T he w a t er c o n t a i n e d i n a c o m p r e s s e d a i r s y s t e m w i l l va r y acc o r d i n g t o a
Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations
VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 5 Guidelines for Design, Equipment and Testing of Gas Welding Installations on Seagoing Ships Edition
Refrigerated Compressed Air Dryers
Refrigerated Compressed Air Dryers 5-6,000 scfm Refrigerated Non-Cycling Refrigerated Cycling Refrigerated High Temperature OWS - 210 Sullair Capabilities Sullair Leadership Since 1965, Sullair has been
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants
TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale
Medical Gas Installation Handbook A-Z. A guide to installing Medical Gas equipment from alarm panels to zone valves.
Medical Gas Installation Handbook A-Z A guide to installing Medical Gas equipment from alarm panels to zone valves. Table of Contents 1.0 Alarms 1.1 Area 1.2 Local 1.3 Master 2.0 Outlets 2.1 Station Outlets/Inlets
DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported
DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported 1 Field of application This standard specifies the colours for the identification of
Marine after-treatment from STT Emtec AB
Marine after-treatment from STT Emtec AB For Your Vessel and the Environment SCR Technology How it works The selective catalytic reduction of nitrous oxides (NOx) by nitrogen compounds such as urea solutions
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
Atlas Copco. Oil-injected rotary screw compressors GX e 7-22 (7-22 kw / 10-30 hp)
Atlas Copco Oil-injected rotary screw compressors GX e 7-22 (7-22 kw / 10-30 hp) BEST QUALITY GX e 7-22: Built to last & save energy The GX e 7-22 brings the power and reliability of an industrial screw
