A Comparative Review of Performance and Application
|
|
|
- Bernice Boone
- 9 years ago
- Views:
Transcription
1 Digital Load Cells A Comparative Review of Performance and Application The Institute of Measurement and Control 87 Gower Street London WC1E 6AF WP0803 Originally published 2003 Reviewed and re-issued 2011
2 COMMITTEE RESPONSIBLE FOR THIS DOCUMENT The Weighing Panel, reporting to the Learned Society Board of the Institute, originally prepared this Document. The persons listed below served as members of the Weighing Panel in its preparation. P Zecchin, Chairman Professor U Erdem, Deputy Chairman J Anthony A Bowen A Knott S Maclean D Smith A Urwin Professor J Pugh C Whittingham B Yarwood Vishay Nobel Ltd Consultant UK Weighing Federation AB Measurement and Control Solutions National Physical Laboratory Thames Side-Maywood Ltd Avery Berkel The Quality Scheme for Ready Mixed Concrete Glasgow Caledonian University M & C Engineers Consultant, Dynamic Weighing This Document is subject to review at any time by the responsible technical group of the Institute. It was reviewed and re-issued in Members of the Weighing and Force Measurement Panel at the time of the 2011 review were: Andy Knott, Chairman Ural Erdem, Deputy Chairman Thomas Allgeier Mike Baker Tony Bowen Paul Dixon Peter Harrison Mark Hopkins John Pugh David Smith Clarry Whittingham National Physical Laboratory Consultant Flintec UK Ltd Sherborne Sensors Ltd AB Measurement & Control Solutions National Measurement Office UKAS Procon Engineering Glasgow Caledonian University Avery Weightronix Ltd Tata Steel The Institute welcomes all comments on this Document and requests that these should be addressed the Institute. Users of this Institute of Measurement and Control Document shall be responsible for its correct application. 2
3 TABLE OF CONTENTS 1 FOREWORD SCOPE TERMS AND DEFINITIONS GENERAL CONSIDERATIONS CALIBRATION Load cell calibration Rationalisation Load distribution LOAD CELL PERFORMANCE Non-linearity Hysteresis Creep Temperature compensation Resolution and repeatability Reliability Diagnostics SYSTEM PERFORMANCE System combined error System temperature error Load distribution error Vibration induced error Synchronisation error Diagnostics HUMIDITY ELECTRICAL STORMS, EMC, AND ELECTRICAL CONNECTIONS SERVICE AND MAINTENANCE ASPECTS Service replacement Interchangeability SYSTEM COST REFERENCES FURTHER READING
4 1 FOREWORD This Institute of Measurement and Control monograph reviews the performance and application of load cells that output their measuring signal in a digital format as opposed to conventional analogue signals. The performance of digital load cells is compared to conventional analogue load cells, particularly in the context of industrial process weighing applications. It gives recognition to the need for a comprehensive and authoritative document for identifying the benefits of using this type of load cell in industrial process weighing systems. The incorporation of digital technology within a load cell may confer benefits to both the user and manufacturer. This document attempts to separate and identify the benefits of each feature. This document is a guide for the technical personnel and organisations engaged in specifying and procuring load cells for industrial process weighing systems, and for those organisations supplying such systems. 2 SCOPE This Monograph reviews all of the principal features relating to strain gauge load cells that incorporate signal conditioning electronics to provide measuring output signals in a digital form. Most load cells which are sold as digital load cells are strain gauge based analogue load cells with built-in electronics to convert the analogue output into a digital output signal. A digital load cell, for the purposes of this document, therefore, comprises a measurement system illustrated in Figure 1. The load cells are presumed to be of the strain gauge type and the signal conditioning electronics is assumed to be contained within the envelope of the transducer housing. The signal conditioning electronics may have a minimum configuration such as an Analogue to Digital Converter to convert the analogue signal into a digital format for retransmission. It may incorporate additional electronic devices to store various load cell performance characteristics and optimise these by the use of software algorithms. Load cells that utilise some of the features of the digital load cell but whose electronics are separately housed or are not dedicated to a single transducer are not considered here. Power Typical Strain Gauge Bridge Sensor Signal Conditioning Electronics Digital Outputs (i.e. weight, status etc.) Digital Inputs (i.e. address, setup parameters etc.) Digital Load Cell Envelope Figure 1: A schematic representation of a digital load cell 4
5 3 TERMS AND DEFINITIONS This Monograph provides recommended terminology and definitions for the terms used herein. No attempt has been made to define those terms defined elsewhere in the document. Some of the acronyms are also included. Where appropriate, these terms and definitions are based on the currently available British, European, or International standards or authoritative documents published by Learned Societies. 3.1 ADC Abbreviation for analogue to digital converter 3.2 ALGORITHM A well-defined set of rules for processing digital signals or solving a problem. Within the context of this document, this may be in the form of a software programme for temperature compensation of the zero load and applied load load cell outputs, or for linearisation of the load cell output 3.3 DCS Abbreviation for distributed control system 3.4 Diagnostics The set of tests to run through a system that determine whether or not the system is functioning correctly 3.5 Digital filtering Mathematical techniques used to reduce or enhance certain aspects of a sampled, discrete-time signal 3.6 EPROM Abbreviation for erasable programmable read-only memory. A read-only memory in which stored data can be erased, by ultraviolet light or other means, and reprogrammed by appropriate voltage pulses 3.7 EEPROM Abbreviation for electrically erasable programmable read-only memory. Sometimes referred as E 2 PROM 3.8 Fieldbus Fieldbus is a method of connecting field instrumentation using a communications network linking the field instruments rather than connecting each field instrument individually to the control system. Fieldbus uses digital communication protocols, which allows information to be communicated between the control system and the field instrument in addition to the process signal. Instrumentation connected to a fieldbus network is always of the smart instrumentation type 3.9 Full scale deflection Difference between the load cell or load cell system output at maximum calibration load and the output at zero load. In this document it is referred as fsd 3.10 Load receiving element The element of weighing system intended to receive the load to be measured, such as a hopper, silo or ladle 5
6 3.11 Non-linearity Maximum deviation of the measured output of the load cell or the load cell system, obtained for increasing loads only, from a best fit polynomial, calculated using the method of least squares. This covers any statistically-supported degree of polynomial, including straight line fits (for a detailed explanation of this term refer to [3]) 3.12 Protocol A set of formal rules describing how to transmit data, especially across a network. Low level protocols define the electrical and physical standards to be observed, bit- and byte ordering, and the transmission and error detection and correction of the bit stream. High level protocols deal with the data formatting, including such issues as syntax of messages, terminal to computer dialogue, character sets, and sequencing of messages 4 GENERAL CONSIDERATIONS This section addresses the various factors that may inform the choice between a digital and analogue load cell for a particular process weighing application. 4.1 CALIBRATION This sub-section considers the calibration of digital load cells and of weighing systems that incorporate them Load cell calibration Much emphasis is placed by manufacturers on claims that digital load cells are pre-calibrated at source and that this fact makes for simple commissioning and service interchange. The definition of calibration used throughout this document is based on the JCGM s International Vocabulary of Metrology [6] and, insofar as it applies to the calibration of load cells, may be paraphrased as follows: Calibration is an operation that, under specified conditions, establishes the relationship between the value of force applied to a load cell and the corresponding value of the indicated load cell output, where both values have associated measurement uncertainties. Establishing and documenting this relationship in the laboratory at the end of the manufacturing process is common practise for both digital and analogue load cells. The fact that the output data from a digital load cell is in numeric form and can be linked to data identifying the individual device makes recording and data retrieval simpler for the manufacturer. There can also be benefits for the user in the ease of handling this data for purposes such as quality control or as a diagnostic tool. When the load cell is used as a component in an industrial process weighing system, there are several influence factors that can affect the relationship between the force exerted by the material being weighed and the force being applied to the load cell. These are well-documented [1,2] and include installation issues such as load cell alignment and piping forces. For this reason, theoretical data on the original manufacturer s calibration of a digital or analogue load cell is acceptable only in applications where verification of performance is not critical or is not practical Rationalisation It is accepted practice to adjust an analogue load cell s sensitivity, expressed in mv (output signal) / 6
7 V (excitation voltage), and its output resistance to nominal values within a tolerance band, in a process known as rationalisation. This is important for applications where these load cells are installed in a multiple load cell application and their outputs are connected in parallel in a junction box. This is a time consuming and costly operation especially in the case of high capacity load cells. Digital load cells have their signal outputs matched utilising the software programmed into their conditioning electronics Load distribution In many weighing systems utilising more than one load cell to support the load receiving element, the distribution of load between the individual load cells can vary considerably. In such applications the relative contribution of each load cell to the total output is clearly important. When using analogue load cells which are not matched sufficiently well during manufacture, there is sometimes a need to introduce (and adjust by testing) compensating circuitry, usually located in the load cell junction box. This procedure can be time-consuming, technically difficult, and costly, but it is not relevant to digital load cells. Digital error correction is physically easier and can result in savings of both time and money, in applications such as the following: high performance platform weighing systems (such as those complying with statutory requirements for use in trade) - where in almost every installation analogue load cells require some adjustment during the commissioning phase of the application high performance vessel weighing systems, where the loading is asymmetric and where testing to establish the system output under such conditions is impractical 4.2 LOAD CELL PERFORMANCE This sub-section reviews how parameters describing the performance of the load cell as a component may be modified by the use of digital techniques. The definitions used to quantify performance parameters are contained in [1,2,3] Non-linearity Digital load cells have the capability to allow the signals from the strain gauges to be linearised before being presented as the final output. This is an advantage to the manufacturer in that the performance of the basic transducer design can assume a lesser importance. An analogue load cell, which might meet a given specification for non-linearity, can be tuned to meet a better specification as a digital device. The maximum performance in terms of non-linearity that could be achieved from a load cell, based on strain gauge technology can be improved by the use of digital techniques. Typically an improvement of the non-linearity by a factor of 30 is possible and a load cell having a non-linearity of 0.1 % fsd computed against a best fit straight line can be improved to % fsd if a polynomial of a suitable order is used instead of a straight line. This is a very attractive facility available to the load cell manufacturer, the limiting factor being the repeatability of the device and the technique used in its calibration. 7
8 Figure 2: Performance parameter definitions based on the best straight line However it should be remembered that the installed weigh system non-linearity is dependent on the method of applying load to the load cell and the system mechanical integrity. The improved non-linearity of a digital load cell may not always be a useful benefit to the industrial user. Figure 3: Performance parameter definitions based on the terminal straight line 8
9 4.2.2 Hysteresis The strain gauge load cell exhibits an output, the value of which depends on whether the applied load is increasing or decreasing. Linearisation using digital processing capability of the decreasing load characteristic as well as the increasing characteristic is complex Creep The output of a load cell following a change in applied load has a small time dependant element called creep. As with hysteresis, it is conceivable that this effect could be digitally modelled and this model can be used to provide compensation but at the time of publication it is not known to have been commercially implemented Temperature compensation The bridge configuration of the strain gauges in a load cell provides substantial automatic temperature compensation for the resistance changes that occur in individual gauges. However the final output of a strain gauge load cell is temperature dependent due to changes in the elasticity of the measuring element and other factors. An analogue load cell utilises additional components within the transducer to compensate for these variations. A digital load cell uses the relationship between temperature and output established during manufacture to compensate the output signals. The power of digital processing can be used to perform this compensation and the algorithms used can be complex and comprehensive. For example, different compensation models can be adopted for different loads. These features are primarily an advantage to the manufacturer but may have some benefit to a user if tighter temperature specifications are achieved. This benefit would need to be evaluated for a particular load cell type and taken into account in the overall appraisal. There is little evidence that improved specifications are in fact on offer Resolution and repeatability The discrimination of a load cell is the smallest change of load that can be detected and may be a very small interval. The repeatability of a load cell is a measure of the agreement between the resulting outputs of several repeated load applications. Provided that the discrimination is sufficiently small to allow the repeatability to be determined there is little point in facilitating resolutions of a much higher level than the repeatability. The repeatability of a load cell can be determined in the laboratory to very high levels, but the industrial environment will limit the practical level of repeatability that can be demonstrated to about 1 part in This level of resolution is available from both conventional analogue and digital systems Reliability There is no evidence to suggest a difference in reliability between digital and analogue load cells and it is considered that any differences are unlikely to be significant Diagnostics Analogue load cells have no integral diagnostic capability. In contrast, digital load cell systems may have the functionality to employ diagnostic techniques to give confidence in the integrity of each 9
10 individual load cell. Although these load cells often work in conjunction and may be connected together by their power supply and/or communication outputs, they are stand-alone units and can be individually addressed. For system diagnostics see SAMPLING TIME A digital load cell presents its output as discrete sequence of data. This inherently leads to timing issues, which will be affected by the number of transducers communicating on a single transmission line as well as the speed and complexity of the data being transmitted. These factors should be evaluated to ensure that relevant data can be available in a timely fashion, particularly in applications involving fast processes. 4.3 SYSTEM PERFORMANCE This sub-section reviews the factors that may inform the choice between a digital and analogue load cell in terms of the performance of the complete weighing system. Whatever the type of load cell used, total system accuracy heavily depends on the mechanical integrity of the weighing system. Whichever type of load cell is selected, it will not solve the problems of a badly designed weighing system. The definitions used to quantify performance parameters are given elsewhere [1,2] System combined error This is an aggregate figure relating to the precision of the measurement that includes non-linearity, hysteresis, and repeatability. Whilst the load cell error characteristic is an important contributor to the overall system combined error, the influences of the mechanical installation and environment are likely to be equally important factors for many, if not most, industrial process weighing systems. To achieve an overall combined error in such systems better than 0.02 % of weigh range is unlikely and to achieve 0.01 % of weigh range is considered the absolute practical limit. If this is accepted as reasonable, there is little to choose between digital and analogue load cells from this performance viewpoint System temperature error The arguments relating to temperature induced error are similar to those presented in sub-section Temperature induced error is always present to some degree in a process application and has many causes, the dominant ones usually being mechanical or other indirect factors. Where the mechanical influences are absent or minimal, such as in weigh scale type systems or free standing tanks or hoppers, there could be benefit arising from the use of digital load cells with enhanced temperature coefficients Load distribution error Applications involving uneven load distribution between the various load cells supporting the load receiving element are very common. Apart from obvious examples like weigh scales and hoppers containing solid materials, all weighing systems utilising four or more load cells are statically indeterminate, i.e. the load supported by each load cell cannot be calculated and indeed will vary with time and the status of the installation mechanics. Systems that use analogue load cells can deliver high performance in such circumstances but only if the individual transducers have been matched in relationship to each other during manufacture [1]. 10
11 Production costs usually dictate the tolerances of this matching procedure and even the best of load cell production output streams will have some mismatch in the output parameters. It may be possible to specifically select matched sets of analogue load cells however in all but the simplest platform situations it is practically impossible to improve these matching characteristics by testing on site. Even where such testing is possible and compensation is provided, using additional resistors that are incorporated into the local summation junction box, there are inevitable time and cost implications. This is an area where digital load cells can offer some significant advantages. Since their individual outputs are observed as a value in actual weight units and arithmetically added together, correction of errors due to uneven load distribution is simplified. This advantage will manifest itself in terms of both the time and cost of field calibration procedures. It must however be pointed out that that there remains a requirement to install the load cell correctly so that the its original calibration result remains valid in the field Vibration induced error Vibration present in an industrial environment can make weight measurements difficult. There is the capability to include, within the processing circuitry of digital load cells, advanced filter algorithms that can reduce the effects of vibration significantly. However, the same techniques can be employed by a weight transmitter connected to conventional analogue devices, so this is considered a neutral feature Synchronisation error A weighing system incorporating more than one load cell and subject to any form of dynamic loading raises issues about how the individual load cell signals are combined. In an analogue system the cells are almost always summated electrically in a local junction box and the combined output is available instantaneously. If the load distribution changes with time, such as in the presence of agitation, the combined output will remain unaffected providing there is no change in total load. In a digital system there is the potential for time delays to occur in the observation and summation of the individual loads. This requirement for synchronisation needs to be considered in the final digital summation processor. The user should satisfy himself that such consideration has been given to all the data collection components in the system Diagnostics The analogue load cells in a conventional multiple load cell weighing system are connected in parallel in a junction box. The resultant combined signal output is the arithmetic average of the output of these load cells. Failure of one load cell in such a system may not be noticed. To overcome this, additional electronics such as an intelligent junction box which can scan the output of each load cell may have to be installed in place of the conventional junction box. In weighing systems using digital load cells, additional diagnostics may be built in the system software where individual load cells are monitored for influence factors such as excessive loads, rapid changes of loads and excessive temperature changes. The main benefit here is due to the ability to be able to monitor each load cell separately. An example of this would be raising an alarm if the load distribution on individual load cells changes beyond the accepted weight distribution 11
12 when weighing a self-levelling product on a multiple load cell weighing system. The use of historical data to provide a normal reference loading profile against which current behaviour can be compared has also been suggested as a diagnostic tool. 4.4 HUMIDITY Strain gauges, if not properly protected, are very sensitive to moisture. The load cell itself depends on the integrity of its encapsulation in both the short and long term for protection and there will be no significant difference between digital and analogue devices in this respect. The same is not true for the interconnecting cables. The higher level output signals in digital cables will be substantially more immune from moisture ingress problems. 4.5 ELECTRICAL STORMS, EMC, AND ELECTRICAL CONNECTIONS. The energy contained in a lightning strike is at such a high level that any electronic device subjected to a direct incident will be damaged. In vulnerable digital and analogue load cell applications, additional protection will be indicated. Similarly, damage caused by electrical welding adjacent to weighing systems is a potential hazard for digital and analogue load cells alike. For lower levels of electromagnetic radiation the digital load cell, with its inherently higher voltage transmission, will have greater immunity from corruption. However, all systems sold in the European Union are required to comply with the relevant EMC directives and systems used in trade must comply with the more stringent requirements for errors induced by electrical fields as stated in EN [4]. The cost of cabling can be lower for a digital load cell system, mostly due to the reduced need for a high specification cable type. There are also some possible savings available if the digital load cell outputs become part of a common bus system. The interfacing aspects of a digital system must also be considered. The ideal concept of a factory populated by weighing systems all linked to an output device by a single cable carrying standard fieldbus compatible data may not be realisable or indeed, from a reliability point of view, desirable. Many digital systems require special interfaces to permit the individual load cell signals to be made usable by an external system. The implications of the cost and maintenance of these interfaces should not be neglected. 4.6 SERVICE AND MAINTENANCE ASPECTS This sub-section reviews the consequences on the long-term ownership of a system incorporating digital load cells. There are a number of factors that may be listed including: ease of service replacement digital storage and retrieval of calibration data in a computer facilities for initial set-up facilities for diagnostics. 12
13 4.6.1 Service replacement The impact of the failure of one digital load cell in a multi load cell application will depend on the system software. Replacement of a failed digital load cell can be implemented fairly speedily with the same type of load cell provided that the system software has the facility to store its past performance in that location. An analogue load cell will often be provided with a manufacturer s calibration certificate which may enable the user to compute and input the replacement performance parameters into the final signal processor. In either case, the load cell replacement could be carried out and the weighing system used, without reverification of the system. The feasibility of this approach will depend on the performance specification and the quality control procedures in place. In the case of a legal-for-trade weighing system, the system will require reverification in accordance with the requirements of OIML R76 [5]. Weighing systems that provide measurements that have an impact on the quality criteria laid down for a process should be reverified after service intervention by an accepted calibration procedure [2] Interchangeability At the time of publication there is little harmonisation between digital load cells from different manufacturers. Each digital weighing system may use unique communication protocols, and unique algorithms incorporated in the load cell, necessitating replacement load cells having to be obtained from the original supplier. This is in contrast to analogue weighing systems where the load cells and the rest of the electronics may be provided and maintained by different suppliers. 4.7 SYSTEM COST The cost of a digital load cell is likely to be higher than that of its analogue counterpart simply because of the additional components required for each load cell. However, although the raw cost of a digital load cell may be higher, the cost of the complete system and its ongoing use may not be, for a number of reasons. A comparison in the initial capital cost of a digital versus an analogue system may be affected by: probable higher cost of the individual load cells reduction in cable cost cost reduction caused by the omission of weighing instrumentation costs associated with interfacing the load cell signals to rest of the users system. Additionally there will be cost of ownership issues. These will usually be more difficult to quantify and may be subjective, but may be a major contributor to the decision making process. Factors to be considered are: costs associated with initial calibration and commissioning production costs relating to performance differences cost impact on the process of a fault diagnosis facility costs due to vulnerability to a single source supplier total cost of after sales support including training, technical support, replacement and reverification. 13
14 5 REFERENCES 1 A guide to the specification and procurement of industrial process weighing systems An Institute of Measurement and Control publication 2 A code of practice for the calibration of industrial process weighing systems An Institute of Measurement and Control publication 3 British Standard BS 8422 Strain gauge load cell systems, calibration method 4 British Standard BS EN : 1994 Metrological aspects of non-automatic weighing instruments (sometimes referred to as NAWI) 5 OIML R76 Non-Automatic Weighing Instruments, Parts 1 and 2 6 JCGM 200:2008(E), International vocabulary of metrology - Basic and general concepts and associated terms (VIM) 6 FURTHER READING Smart Load Cell Systems by Jan Kersten ISWM-1998 An application report from Revere transducers Plug & Weigh TM Systems Application Note 01-05/99/01 Ian Fellows Ltd Intelligent Load Cells and the Fieldbus by Steve Maclean. Measurement + Control, the Journal of the Institute of Measurement and Control, pp 13-16, Vol 36/1, February 2003 Force and Weight Measurements by Ural Erdem, Journal of Physics E; Scientific Instruments, pp , Vol 15 (1982) 14
A Code of Practice for the Calibration of Industrial Process Weighing Systems
A Code of Practice for the Calibration of Industrial Process Weighing Systems The Institute of Measurement and Control 87 Gower Street London WC1E 6AF WGC0496 Originally published 1996 Reviewed and re-issued
Load Cell Accuracy in Relation to the Conditions of Use
VPG TRANSDUCERS Load Cells and Weigh Modules Technical Note VPGT-0 Load Cell Accuracy in Relation to the Conditions of Use. Load Cell Accuracy Load cells are ranked, according to their overall performance
Procon Engineering. Technical Document PELR 1002. TERMS and DEFINITIONS
Procon Engineering Technical Document PELR 1002 TERMS and DEFINITIONS The following terms are widely used in the weighing industry. Informal comment on terms is in italics and is not part of the formal
Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM
Force measurement Forces VECTORIAL ISSUES In classical mechanics, a force is defined as "an action capable of modifying the quantity of movement of a material point". Therefore, a force has the attributes
THE STRAIN GAGE PRESSURE TRANSDUCER
THE STRAIN GAGE PRESSURE TRANSDUCER Pressure transducers use a variety of sensing devices to provide an electrical output proportional to applied pressure. The sensing device employed in the transducers
Load Cell Troubleshooting
VPG TRANSDUCERS Load Cells and Weigh Modules Technical Note VPGT-08 Scope Load cells are designed to sense force or weight under a wide range of adverse conditions; they are not only the most essential
DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION
DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION Introduction The outputs from sensors and communications receivers are analogue signals that have continuously varying amplitudes. In many systems
PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features
Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (12) 77 7R QUALIFICATION OF EQUIPMENT ANNEX 8: QUALIFICATION OF BALANCES Full document title and reference Document type Qualification
Subminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
The Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
Various Technics of Liquids and Solids Level Measurements. (Part 3)
(Part 3) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles,
Road Vehicles - Diagnostic Systems
SSF 14230 Road Vehicles - Diagnostic Systems Keyword Protocol 2000 - Part 1 - Physical Layer Swedish Implementation Standard Document: SSF 14230-1 Status: Issue 3 Date: October 22, 1997 This document is
Temp. & humidity Transmitter Instructions
Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity
Computers. Hardware. The Central Processing Unit (CPU) CMPT 125: Lecture 1: Understanding the Computer
Computers CMPT 125: Lecture 1: Understanding the Computer Tamara Smyth, [email protected] School of Computing Science, Simon Fraser University January 3, 2009 A computer performs 2 basic functions: 1.
Errors Due to Shared Leadwires in Parallel Strain Gage Circuits
Micro-Measurements Strain Gages and Instruments Errors Due to Shared Leadwires in Parallel Strain Gage Circuits TN-516 1. Introduction The usual, and preferred, practice with multiple quarterbridge strain
Estimating Weighing Uncertainty From Balance Data Sheet Specifications
Estimating Weighing Uncertainty From Balance Data Sheet Specifications Sources Of Measurement Deviations And Uncertainties Determination Of The Combined Measurement Bias Estimation Of The Combined Measurement
Performance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals
traffic systems and signing TR 2503 Issue B February 2006 Performance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals Crown Copyright 2005 First published 2005 Printed and
Introduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01
Introduction The requirements relating to driving safety, driving comfort, exhaust emissions and fuel economy are are becoming ever more stringent. This entails more intensive information exchange between
DHT11 Humidity & Temperature Sensor D-Robotics UK (www.droboticsonline.com)
DHT11 Humidity & Temperature Sensor D-Robotics UK (www.droboticsonline.com) DHT11 Temperature & Humidity Sensor features a temperature & humidity sensor complex with a calibrated digital signal output.
2.0 Command and Data Handling Subsystem
2.0 Command and Data Handling Subsystem The Command and Data Handling Subsystem is the brain of the whole autonomous CubeSat. The C&DH system consists of an Onboard Computer, OBC, which controls the operation
EC type-examination certificate UK/0126/0099
UK/0126/0099 MI-006 EC type-examination certificate UK/0126/0099 Issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments (Automatic
DPI 260 SERIES: Digital Pressure Indicators
DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies
An Overview of Calibration Methods and Procedures for Process and Inventory Weigh Systems
BLH NOBEL Weighing Systems Brands of VPG Process Weighing Solutions for Process Weighing and Force Measurement Handbook TC0010 Procedures for Process and Inventory Weigh Systems Allen-Bradley Automation
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
Avoiding AC Capacitor Failures in Large UPS Systems
Avoiding AC Capacitor Failures in Large UPS Systems White Paper #60 Revision 0 Executive Summary Most AC power capacitor failures experienced in large UPS systems are avoidable. Capacitor failures can
Gravimetric determination of pipette errors
Gravimetric determination of pipette errors In chemical measurements (for instance in titrimetric analysis) it is very important to precisely measure amount of liquid, the measurement is performed with
Practical Application of Industrial Fiber Optic Sensing Systems
Practical Application of Industrial Fiber Optic Sensing Systems John W. Berthold and David B. Needham Davidson Instruments, Inc. P.O. Box 130100, The Woodlands, TX 77393 ABSTRACT In this presentation,
Software Requirements Specification
1 of 7 17.04.98 13:32 Software Requirements Specification The sub-sections : 1. What is a Software Requirements Specification 2. Why is a Software Requirement Specification Required 3. What is Contained
telemetry Rene A.J. Chave, David D. Lemon, Jan Buermans ASL Environmental Sciences Inc. Victoria BC Canada [email protected] I.
Near real-time transmission of reduced data from a moored multi-frequency sonar by low bandwidth telemetry Rene A.J. Chave, David D. Lemon, Jan Buermans ASL Environmental Sciences Inc. Victoria BC Canada
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS
PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15 TUTORIAL OUTCOME 2 Part 1
UNIT 22: PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15 TUTORIAL OUTCOME 2 Part 1 This work covers part of outcome 2 of the Edexcel standard module. The material is
ERRATUM: OIML R 60 RECOMMENDATION. Edition 2000 (E) ORGANISATION INTERNATIONALE ORGANIZATION INTERNATIONAL. Metrological regulation for load cells
ERRATUM: INTERNATIONAL RECOMMENDATION OIML R 60 Edition 2000 (E) Metrological regulation for load cells THIS ERRATUM ONLY CONCERNS THE ENGLISH VERSION OF R 60 (2000) ORGANISATION INTERNATIONALE DE MÉTROLOGIE
High-Precision Platforms
High-Precision Platforms PBK9 and PFK9 Weighing Platforms High-precision weighing Reliable in harsh conditions Fast weighing processes Flexible for many applications High Accuracy For Harsh Environments
Measuring Temperature withthermistors a Tutorial David Potter
NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in
(Uncertainty) 2. How uncertain is your uncertainty budget?
(Uncertainty) 2 How uncertain is your uncertainty budget? Paper Author and Presenter: Dr. Henrik S. Nielsen HN Metrology Consulting, Inc 10219 Coral Reef Way, Indianapolis, IN 46256 Phone: (317) 849 9577,
NMI R 125 Measuring Systems for the Mass of Liquids in Tanks
NMI R 125 Measuring Systems for the Mass of Liquids in Tanks (OIML R 125:1998(E), IDT) The English version of international standard OIML R 125:1998 Measuring Systems for the Mass of Liquids in Tanks (1998)
LCWM Glossary. Mettler Toledo LCWM Glossary
Mettler Toledo LCWM Glossary LCWM Glossary Accuracy A measure of a Scale s ability to provide a weight reading equal to the actual weight placed on the Scale. A Scale s accuracy is usually measured against
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
CE Marking and Technical Standardisation
GAMBICA Technical Guide CE Marking and Technical Standardisation Guidelines for application to Electrical Power Drive Systems Edition 4 : 2015 CE Marking and Technical Standardisation Guidelines for application
Experience with taximeters with a look at the corresponding tables
Experience with taximeters with a look at the corresponding tables Milan Prasil CMI Laboratory of the fundamental metrology V Botanice 4, 150 72 Prague 5 [email protected] Taximeters in EU are subject to
WHAT DESIGNERS SHOULD KNOW ABOUT DATA CONVERTER DRIFT
WHAT DESIGNERS SHOULD KNOW ABOUT DATA CONVERTER DRIFT Understanding the Components of Worst-Case Degradation Can Help in Avoiding Overspecification Exactly how inaccurate will a change in temperature make
Perimeter Security System
TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated
INTREPID Perimeter Intrusion Detection System
TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.
DOCUMENT CS/1: SCHEME DESCRIPTION AND BENEFITS
WELDING FABRICATOR CERTIFICATION SCHEME DOCUMENT CS/1: SCHEME DESCRIPTION AND BENEFITS 6 th Edition July 2012 Issued under the authority of the Governing Board for Certification All correspondence should
Inventory Control. Inventory Control Tank & Silo Weighing
Inventory Control Tank & Silo Weighing Gravimetric level control is one of the most accurate inventory control methods available. Its high degree of accuracy makes it particularly helpful when measuring
C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning
C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning Document Number: CBUS-APP/25 Comments on this document should be addressed to: Engineering Manager Clipsal Integrated Systems PO Box 103
PC BASED PID TEMPERATURE CONTROLLER
PC BASED PID TEMPERATURE CONTROLLER R. Nisha * and K.N. Madhusoodanan Dept. of Instrumentation, Cochin University of Science and Technology, Cochin 22, India ABSTRACT: A simple and versatile PC based Programmable
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Maximization versus environmental compliance
Maximization versus environmental compliance Increase use of alternative fuels with no risk for quality and environment Reprint from World Cement March 2005 Dr. Eduardo Gallestey, ABB, Switzerland, discusses
22.302 Experiment 5. Strain Gage Measurements
22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified
Temperature Sensors. Resistance Temperature Detectors (RTDs) Thermistors IC Temperature Sensors
Temperature Sensors Resistance Temperature Detectors (RTDs) Thermistors IC Temperature Sensors Drew Gilliam GE/MfgE 330: Introduction to Mechatronics 03.19.2003 Introduction There are a wide variety of
1 Coffee cooling : Part B : automated data acquisition
1 COFFEE COOLING : PART B : AUTOMATED DATA ACQUISITION 1 October 23, 2015 1 Coffee cooling : Part B : automated data acquisition Experiment designed by Peter Crew, Navot Arad and Dr Alston J. Misquitta
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has
PROFIBUS AND MODBUS: A COMPARISON
Real-Time Information for the Automation Professional TM PROFIBUS AND MODBUS: A COMPARISON By James Powell, Siemens October 2013 We live in a multi-protocol world and this will likely not change anytime
ABB i-bus EIB / KNX Weather Station WS/S 4.1
Product Manual ABB i-bus EIB / KNX Weather Station WS/S 4.1 Intelligent Installation Systems This manual describes the function of the Weather station WS/S 4.1. Subject to changes and errors excepted.
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1
SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable
Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement
Chapter 2 Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement 2.1 Introduction and Objectives This laboratory exercise involves the static calibration
SINGLE-SUPPLY OPERATION OF OPERATIONAL AMPLIFIERS
SINGLE-SUPPLY OPERATION OF OPERATIONAL AMPLIFIERS One of the most common applications questions on operational amplifiers concerns operation from a single supply voltage. Can the model OPAxyz be operated
Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK
code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475
Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration
Relative Humidity Measurement and Calibration The widest range of humidity products from a pioneer of RH sensor development The best in Relative Humidity technology to optimize your process Whether you
Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the
DVI Interface The outline: The reasons for digital interface of a monitor the transfer from VGA to DVI. DVI v. analog interface. The principles of LCD control through DVI interface. The link between DVI
For the Design, Installation, Commissioning & Maintenance of Fixed Gaseous Fire Suppression Systems
BAFE Scheme: SP203-3 Version 1: July 2008 Amendment No: 1 Fire Protection Industry Scheme, Reference SP203 Part 3 For the Design, Installation, Commissioning & Maintenance of Fixed Gaseous Fire Suppression
Section 3. Sensor to ADC Design Example
Section 3 Sensor to ADC Design Example 3-1 This section describes the design of a sensor to ADC system. The sensor measures temperature, and the measurement is interfaced into an ADC selected by the systems
R 60 DoMC-01 rev.1 Additional requirements from the United States. Accuracy class III L. Revision number Date of the revision Nature of the revision
R 60 DoMC-01 rev.1 Additional requirements from the United States Accuracy class III L Revision number Date of the revision Nature of the revision Rev.0 29/09/2006 Initial document Rev.1 03/03/2014 Update
CMMs and PROFICIENCY TESTING
CMMs and PROFICIENCY TESTING Speaker/Author: Dr. Henrik S. Nielsen HN Metrology Consulting, Inc. HN Proficiency Testing, Inc. Indianapolis, Indiana, USA [email protected] Phone: (317) 849 9577;
Guide to the Measurement of Force
Guide to the Measurement of Force The Institute of Measurement and Control 87 Gower Street London WC1E 6AF ISBN 0 904457 28 1 Originally published 1998 Reviewed and re-issued 2013 COMMITTEE RESPONSIBLE
A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION
35'th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting San Diego, December 2-4, 2003 A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
RESULTS OF TESTS WITH DOMESTIC RECEIVER IC S FOR DVB-T. C.R. Nokes BBC R&D, UK ABSTRACT
RESULTS OF TESTS WITH DOMESTIC RECEIVER IC S FOR DVB-T C.R. Nokes BBC R&D, UK ABSTRACT Digital terrestrial television services using the DVB-T standard will be launched later this year in the UK, followed
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
PLC Based Liquid Filling and Mixing
PLC Based Liquid Filling and Mixing 1 Mihir Panchal, 2 Aashish Panaskar. 3 Prof. Lalit Kumar KJ College of Engineering and Management Research, Pune, India Abstract: The objective of this paper is to design,
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment
(Jan 2005) (Corr.1 Nov 2005) (Rev.1 Oct 2006) (Corr.1 Oct 2007) (Rev.2 Feb 2015) Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment 1. Scope 1.1 To specify the tests required to
Testing for the Unexpected: An Automated Method of Injecting Faults for Engine Management Development
Testing for the Unexpected: An Automated Method of Injecting Faults for Engine Management Development By Shaun Fuller What will happen if a fault occurs in an automotive vehicle s electrical system? Similarly,
Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology
Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology Summary The increasing customer requirements for comfort and safety and
DLO1191 Linear smoke detector
DLO1191 Linear smoke detector collective/synoline600, interactive AlgoRex Synova Reliable smoke detection in large-volume rooms (inside application) Detection distance from 5 100 Meter Efficient signal
Test Automation Architectures: Planning for Test Automation
Test Automation Architectures: Planning for Test Automation Douglas Hoffman Software Quality Methods, LLC. 24646 Heather Heights Place Saratoga, California 95070-9710 Phone 408-741-4830 Fax 408-867-4550
Pressure Transducer to ADC Application
Application Report SLOA05 October 2000 Pressure Transducer to ADC Application John Bishop ABSTRACT Advanced Analog Products/OpAmp Applications A range of bridgetype transducers can measure numerous process
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
Enhancing High-Speed Telecommunications Networks with FEC
White Paper Enhancing High-Speed Telecommunications Networks with FEC As the demand for high-bandwidth telecommunications channels increases, service providers and equipment manufacturers must deliver
Device Type Manager (DTM) Basic HART
Technical Information 30/72-8850-0 EN FDT Device Type Manager (DTM) Basic HART Contents: 1 Features / Application.................................................. 2 1.1 General...........................................................................
An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware
for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved
NI USB-5681 RF Power Meter Specifications
NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
AN437. Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS. 1. Introduction. 2. Relevant Measurements to comply with FCC
Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS 1. Introduction This document provides measurement results and FCC compliance results for the Si4432B when operated from 902 928 MHz. The measurement
SEMICONDUCTOR TECHNICAL DATA
SEMICONDUCTOR TECHNICAL DATA Order this document by MPX5050/D The MPX5050 series piezoresistive transducer is a state of the art monolithic silicon pressure sensor designed for a wide range of applications,
Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network
traffic systems and signing TR 2522 Issue A October 2005 Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network Crown Copyright 2005 First published 2005 Printed and
PROFIBUS/PROFINET System design
PROFIBUS/PROFINET System design Andy Verwer Technical Officer for PROFIBUS UK Verwer Training & Consultancy Ltd Gold distributor PROFIBUS PROFIBUS is by a large margin the most widely used fieldbus technology.
Environmental Monitoring with Sensors: Hands-on Exercise
Environmental Monitoring with Sensors: Hands-on Exercise Now that you ve seen a few types of sensors, along with some circuits that can be developed to condition their responses, let s spend a bit of time
Vehicle Engine Management Systems
Unit 11: Vehicle Engine Management Systems NQF level 3: Guided learning hours: 60 BTEC National Unit abstract Modern motor vehicles continue to make use of the rapid advances in electronics technology
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)
(Part # S-LIB-M003) The smart sensor is designed to work with the HOBO Weather Station logger. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Weather Station.