Price groups and supply availability 5 General notes and abbreviations 6 Planning guide 11. Heating, air-conditioning, cooling 13

Size: px
Start display at page:

Download "Price groups and supply availability 5 General notes and abbreviations 6 Planning guide 11. Heating, air-conditioning, cooling 13"

Transcription

1 Contents Heating, air-conditioning, cooling Price groups and supply availability 5 General notes and abbreviations 6 Planning guide 11 Heating, air-conditioning, cooling 13 Glandless high-efficiency pumps Single pumps Wilo-Stratos PICO 13 Coming soon! Wilo-Yonos PICO 14 Wilo-Stratos ECO...-BMS 15 Wilo-Stratos 16 Double pumps Wilo-Stratos-D 18 Heizung, Klima, Kälte Glandless automatic pumps Single pumps Wilo-Smart 19 Glandless standard pumps Single pumps Wilo-Star-RS 2 Double pumps Wilo-Star-RSD 21 Single pumps Wilo-TOP-S 22 Double pumps Wilo-TOP-SD 24 Wilo-TOP-D 26 Wasserversorgung Glanded high-efficiency pumps Single pumps Wilo-Stratos GIGA 28 Glanded energy-saving pumps Single pumps Wilo-VeroLine-IP-E 3 Wilo-CronoLine-IL-E 32 Double pumps Wilo-VeroTwin-DP-E 36 Wilo-CronoTwin-DL-E 38 Abwasser Glanded standard pumps Single pumps Wilo-VeroLine-IPL 41 Wilo-CronoLine-IL 44 Double pumps Wilo-VeroTwin-DPL 52 Wilo-CronoTwin-DL 55 Glanded special pumps Single pumps Wilo-VeroLine-IPS 6 Wilo-VeroLine-IPH-W/-O 61 Glanded monobloc pumps Single pumps Wilo-BAC 65 Wilo-CronoBloc-BL 66 Schalt- und Regelgeräte/ Pumpenmanagement Wasserversorgung 3

2 Contents Heating, air-conditioning, cooling Glanded norm pumps Single pumps Wilo-Crono-Norm-NL 71 Wilo-VeroNorm-NPG 89 Glanded axially split case pumps Single pumps Wilo-SCP 91 Solar thermal, geothermal, systems 92 Glandless high-efficiency pumps Single pumps Wilo-Stratos ECO-ST 92 Glandless high-efficiency pumps Single pumps Wilo-Star-ST 93 Secondary hot water 94 Glandless high-efficiency pumps Single pumps Wilo-Star-Z NOVA 94 Wilo-Stratos ECO-Z 95 Wilo-Stratos-Z 96 Glandless standard pumps Single pumps Wilo-Star-Z 98 Wilo-TOP-Z 99 Glanded special pumps Single pumps Wilo-VeroLine-IP-Z 11 Accessories 12 Operating and service unit 12 Threaded pipe unions, mounting feet, blind plates Stratos-D/TOP-SD 13 Adapter fittings, flanged rings, flange pieces 16 Wilo modular concept (spare motors RMOT) 19 Mounting feet, special mechanical seals 117 Blind plates for glanded pumps, differential pressure sensors 118 Control/Device, switchgears Plug-in modules, differential pressure switches, motor protection, accessories 121 Inverters Stand Alone Inverter Drive 122 Pump control Wilo-interface modules (IF-Module-Stratos, IF-Module) 123 Wilo-Protect-Module-C 125 Systems 127 Condensate lifting units Wilo-DrainLift Con 127 4

3 Price groups and supply availability Price group key and supply availability Price group W Price group W1 Price group W2 Price group W3 All small screw-end pumps All Star pump types: Star-RS, Star-Z NOVA, Star-RSD, Star-Z 15TT up to Z 25/6, Star-ST, Star-RSG, Star-ZD, Smart High-efficiency pumps, electronically controlled flange-end pumps and big screw-end pumps Stratos, Stratos-D, Stratos-Z, Stratos-ZD, spare motors for above-mentioned pumps Yonos PICO, Stratos PICO, Stratos ECO-BMS, Stratos ECO-Z, Stratos ECO-ST, spare motors for TOP-E, TOP-ED and TOP-EV Standard flange-end and big screw-end pumps TOP-S, TOP-SD, TOP-D, TOP-Z, spare motors for above-mentioned pumps, spare motors for RP, P, DOP Accessories for pump control DigiCon-LBF, Protect module, CC-/CCe system, VR-HVAC system, plug-in modules, full motor protection, screwed connections, adapters, capacitors, Wilo-Safe Price group W4 Price group W5 Price group W6 Price group W7 Glanded high-efficiency pumps VeroLine-IP-E, VeroTwin- DP-E, CronoLine-IL-E, CronoTwin-DL-E, DL-E Standard-Pumpen VeroLine-IPL, IP-Z, IPS, VeroLine-IPH-W, IPH-O, VeroTwin-DPL, CronoLine-IL, CronoTwin-DL, CronoBloc-BL, BAC, CronoNorm-NL, NPG, SCP Water supply Pumps and systems for house and garden, rainwater utilisation, submersible pumps, high-pressure centrifugal pumps, accessories Drainage/sewage Pumps for wastewater/drainage (except for Wilo-EMU KS see price group W8), pumps for sewage/faeces (except for Wilo-EMU FA - see price group W8), lifting units for condensate/ wastewater/drainage, lifting units for sewage/faeces, synthetic pumps stations System technology sanitary engineering Pressure boosting and fire fighting systems, accessories Price group W8 Price group W9/WD Price group WG Price group WE Pumps for wastewater: Wilo-EMU KS, sewage/ faeces: Wilo-EMU FA Service Spare parts, services, customer service Geniax All components of the decentralised pump system Wilo-Geniax High-efficiency glanded pumps Stratos-GIGA Supply availability key ]=supply availability L=normally available ex stock C=components available ex stock, assembly to order within approx. 2 weeks K=components available ex stock, assembly to order within approx. 4 weeks A = delivery time on request This price list supersedes all previous price documentation which thus become invalid. All product illustrations of respective product series are symbolic presentations only. Effective from 1 October 211 in Germany. Article numbers in bold type These products were modified or are new. 5

4 General notes and abbreviations Abbreviation Meaning 1~ 1-phase current 3~ 3-phase current blsf BACnet Blocking current-proof, no motor protection required Internationally defined company-neutral standard for data communication in building automation systems (ISO ). CAN (Controller Area Network) - Multi master bus system, in which several equal CAN-devices may communicate via a 2-core bus within very short cycle CAN times. The Wilo-CAN bus includes a CANopen Standard (EN ) which is independent of the supplier. DM Three-phase motor, 3~ DN Δp Δp-c Δp-T Δp-v ΔT EBM ECM technology Nominal diameter of the flange connection Differential pressure Control mode for constant differential pressure Control mode for differential pressure control depending on the fluid temperature Control mode for variable differential pressure Control mode for differential temperature Individual run signal Electronically commutated motor with new wet rotor encapsulation, newly developed glandless drive concept for high-efficiency pumps EM Single-phase motor, 1~ EnEV ErP ESM Ext. Off Ext. Min FI BA Geniax-BUS GRD/GLRD dh H IF Int. MS IR German Energy Conservation Legislation It applies to energy-related products. ErP Directive 29/125/EC establishing a framework for the setting of environmentally-responsible requirements for energy-driven products. Formerly the Ecodesign Directive (EuP Directive 25/32/EC). Individual fault signal Overriding Off control input Control input Overriding Min, e. g. for automatic setback operation Residual current-operated protective device Building automation Master/slave BUS system, specified for the requirements of the Geniax system, derived from CAN-BUS technology. Up to 252 Geniax components can communicate with a server with short cycle times via a 2- wire BUS. The Geniax BUS is not compatible with other CAN-BUS systems. Mechanical seal Degree of German water hardness; formerly used unit for assessing the water hardness. Is no longer used since the SI-unit mmol/l has been introduced. Conversion: 1 dh =.1783 mmol/l Delivery head Interface Infrared interface Abbreviation KDS KLF Internal motor protection: pumps with internal protection against unacceptably high winding temperatures Cataphoretic coating KTW LON Modbus mmol/l MOT P 1 PELV PLR Q (= ) RMOT SELV SBM SSM Control input, - 1 V TrinkwV 21 VDI 235 Wilo-Control WRAS WSK X Meaning Capacitor PTC thermistor sensor Cataphoretic coating (electrophoretically deposited paint, EDP): paintwork with high adhesive strength for long-lasting corrosion protection Approval for products with plastics, for utilisation in potable water applications Local Operating Network (open data bus system, standardised and independent of any single manufacturer, in LONWorks networks) Communication protocol based on a master/slave architecture. Ethernet and RS485 are used as the media of transmission. Widespread in industrial and building automation applications. Millimols per litre; SI unit for assessing water hardness (total hardness, or concentration of alkaline earth ions) Motor module (drive motor + impeller + terminal box/ electronics module) for replacement Power consumption (power supplied from the network) Protective Extra Low Voltage; PELV ( Protective Extra Low Voltage, formerly functional extra low voltage with safe isolation ) provides extra protection from electric shock. The voltage is so low that electrical shock currents are normally not dangerous. However, unlike SELV, active parts and components of the equipment must be earthed and connected with the protective earth conductor. Pump master computer, Wilo-specific data interface Volume flow Spare motor (drive motor + impeller + terminal box/ electronics module) for replacement Safety Extra Low Voltage; SELV (formerly safety low voltage ) is a low electrical voltage that offers special protection against electric shocks compared to electric circuits with higher voltages due to the low voltage level and the insulation. The voltage is so low that electrical shock currents are normally not dangerous. Run signal or collective run signal Fault signal or collective fault signal Analogue input for external activation of functions German Drinking Water Ordinance of 21 (valid from ) VDI guideline for preventing damage in hot-water heating installations Building automation management with pumps and accessories Water Regulations Advisory Scheme (potable water approval for Great Britain and Northern Ireland) Thermal winding contacts (in motor for monitoring the winding temperature, full motor protection through additional tripping unit) Operating mode of double pumps: Individual operation of the respective duty pump 6

5 General notes and abbreviations Abbreviation Y,. - Meaning Operating mode of double pumps: Parallel operation of both pumps Number of poles of electric motors: 2-pole motor = approx. 29 rpm at 5 Hz Number of poles of electric motors: 4-pole motor = approx. 145 rpm at 5 Hz Number of poles of electric motors: 6-pole motor = approx. 95 rpm at 5 Hz 7

6 General notes and abbreviations Material Meaning AISI Chromium steel X2Cr Chromium steel X46Cr Chromium steel X17CrNi Chromium steel X39CrMo Chromium-nickel steel X5CrNi Chromium-nickel steel X8CrNiS Chromium-nickel steel X2CrNi L Chromium-nickel steel X2CrNi L Abrasite Al Ceram Composite EN-GJL EN-GJS G-CuSn1 GfK GG GJMW GGG Inox NiAl-Bz PPO PP-GF3 PUR SiC Chromium-nickel-molybdenum steel X5CrNiMo Chromium-nickel-molybdenum steel GX5CrNiMo Chrome nickel molybdenum steel X2CrNiMo Chromium-nickel-molybdenum steel X2CrNiMoN Chromium-nickel steel with titanium addition X6CrNiTi18-1 Chromium-nickel steel with copper and niobium additions X5CrNiCuNb16-4 Chromium-nickel steel with titanium addition X6CrNiMoTi Chilled cast iron material for use in strongly abrasive fluids Light metal material (aluminium) Coating with very high adhesive strength for long-lasting corrosion protection High-strength plastic material Cast iron with lamellar graphite, also referred to as grey cast iron. The use of grey cast iron in domestic water systems is governed by the Drinking Water Directive 98/83/EC and applicable recognised technical rules and standards! Cast iron with spheroidal graphite, also referred to as spheroidal cast iron. The use of spheroidal cast iron in domestic water systems is governed by the Drinking Water Directive 98/83/EC and applicable recognised technical rules and standards! Zinc-free bronze Fibreglass plastic See EN-GJL Special cast iron: white malleable cast iron (former designation: GTW) See EN-GJS Stainless steel Nickel-aluminium bronze Trade name: Noryl, fibreglass-reinforced plastic Polypropylene, reinforced with 3% fibreglass Polyurethane Silicon carbide (225) Ti Material Meaning AISI St Wear and tear Pumps or parts of pumps are subject to wear in accordance with the state-of-the-art (DIN 3151/DIN-EN 1336). This wear may vary depending on operating parameters (temperature, pressure, speed, water conditions) and the installation/usage situation and may result in the malfunction or failure at different times of the aforementioned products/components, including their electrical/electronic circuitry. Wearing parts are all components subject to rotary or dynamic stress, including electronic components under tension, in particular: Seals (including mechanical seals), seal rings Stuffing box Bearings and shafts Impellers and pump components Wear rings and counter rings Stationary wear rings/wear plates Macerator Capacitors Relays/contactors/switches Electronic circuits, semiconductor components, etc. Pumps and continuous-flow machines (like submersible mixers and recirculation pumps), as well as their coated components (cataphoretic, 2K or Ceram coating) are subject to constant wear due to the abrasive fluid contents. For this reason the coating is also counted as a wearing part of these units! We do not accept any liability for faults or defects arising from natural wear and tear. Note In accordance with German Energy Saving Ordinance [Energieeinspar-Verordnung EnEV] as of the at boiler outputs from 25 kw, heating pumps are to be equipped with switchgears for automatic performance control or electronically controlled pumps are to be installed. In accordance with TrinkwV 21 and DIN 593-6, only circulating pumps with corrosion-resistant pump housings made of stainless steel or red brass (CC 499K) are to be utilized in secondary hot water circulation systems. Pump replacement Detailed information on the subject of Replacing heating pumps can be found in the current Wilo replacement guide for heating pumps. Wilo General Terms of Delivery and Service The latest version of our General Terms of Delivery and Service can be found on the Internet at Steel V2A Material group, e.g , V4A Material group, e.g ,

7 General notes ErP (ecological design) guideline ErP Directive (29/125/EU) In the year 25 the European Union passed the new directive 25/32/EC with requirements for the environmentally sound design of energy-using products. It has become known as the EuP or Eco-Design directive. The abbreviation EuP stands for energy using products, and it means that the directive covers all products which consume energy (apart from motor vehicles and public means of transport). On 2th November 29 it was replaced by the new directive 29/125/EC. The most important change is that the area of application was widened from energy-driven products to energyrelated products. Accordingly, it is now usually abbreviated as ErP directive. Circulation pumps of glandless design and electric motors of glanded pumps are also covered by the ErP directive. In 29 the EU Commission defined minimum efficiency requirements in two regulations. These go far beyond the requirements of the current energy efficiency requirements for glandless pumps or the current best class EFF1 for electric motors. The ordinances will be implemented in several steps in the coming years. In this way, the highly efficient individual pump series Wilo-Stratos and Wilo-Stratos PICO already meet the particularly strict requirements of the second stage of the ordinance for glandless circulation pumps which is to apply from 215 onwards. They can thus contribute to increased energy efficiency in heating systems not just from 213, but immediately! APPLIES TO EUROPEAN DIRECTIVE FOR ENERGY RELATED PRODUCTS Glandless circulation pumps: The market for glandless pumps especially will be significantly changed by this. After all, until now in many EU countries virtually all models in use have been without speed control. These have an enormous energy consumption, however. In contrast, considerable potential savings and greenhouse gas reductions can be achieved with high-efficiency pumps due to their particularly low electricity consumption. Throughout Europe, the EU Commission Directive could save about half the energy consumption of glandless circulation pumps by the third stage of implementation in 22. This amounts to the giant quantity of 23 terawatt hours of energy per year the energy production of approx. six medium-sized coal-fired power stations. Across Europe, this corresponds to a reduction of CO2 emissions of about 11 million tonnes per year.. The yardstick for determining which pump models can continue to be used in future is referred to as the energy efficiency index (EEI). This is calculated using a process defined in the ordinance (EC) 641/29. The average electrical power of pump is calculated on the basis of a load profile in relation to a reference pump, i.e. an average pump with the same hydraulic output. Three stages are planned: 1. From January 213, the Energy Efficiency Index (EEI) limit value for glandless circulating pumps installed outside the heat generator (external pumps) will be defined as.27. The previous energy efficiency classes will then no longer exist. As a rule, pumps far exceed the minimum efficiency requirements of the current energy efficiency class A. This is why the energy efficiency classes will be replaced by an EEI marking on the pump. 2. From August 215, the EEI limit value will be reduced further to.23. This will also apply to glandless circulation pumps, designed to operate in newly installed heat generators or solar thermal systems (integrated pumps). 3. In the last implementation stage, the regulations starting from 22 will also apply for the replacement of integrated pumps in existing heat generators. All glandless circulation pumps in the heating, air-conditioning and solar sectors will be affected. Secondary hot water circulation pumps are an exception to this. 9

8 General notes ErP (ecological design) guideline Glanded pumps: An appropriate EU regulation for conventional electric motors has taken effect earlier than the one planned for glandless circulation pumps. It also applies to units installed in glanded pumps for heating, air-conditioning, water supply, pressure boosting and sewage disposal. New efficiency classes have been defined against this background. EFF has become IE From 16th June 211 motorised glanded pumps may be placed on the market only if their motors demonstrate a minimum motor efficiency class of IE2. The designation IE stands for International Efficiency and defines globally applicable efficiency classes for low-voltage three-phase AC asynchronous motors in the power range from.75 to 375 kw. It is based on the new IEC 634-3:28 standard. It supersedes the division into three efficiency classes EFF1 to EFF3 which has applied in Europe since APPLIES TO EUROPEAN DIRECTIVE FOR ENERGY RELATED PRODUCTS The following motor efficiency classes have been defined: IE1 = Standard efficiency, approximately comparable to EFF2 IE2 = High efficiency, approximately comparable to EFF1 IE3 = Premium efficiency IE4 = Super-premium efficiency (IEC TS Ed.1) Three stages were defined for the conversion: 1. Efficiency level IE2 must be complied with from 16th June 211 by all new sales of electric motors on the market apart from a few design types and applications. Pump motors with the currently established efficiency level EFF2 which will be called IE1 in the future may then no longer be sold in the European Union. 2. From 1st January 215, an even stricter efficiency level IE3 will apply. By this time, motors with a rated output power of 7.5 to 375 kw must reach this level. Alternatively, they must meet efficiency level IE2 and be equipped with speed control. 3. From 1st January 217, these requirements will apply also to motors with a rated output power of.75 to 375 kw. Against this background, since 1st January 211 all glanded pumps supplied by Wilo have been already equipped with IE2 motors. Thus the requirements of the first stage of the ErP Directive have been satisfied ahead of time. The ErP Directive also applies to pressure boosting systems. Therefore for several months, Wilo has for instance been offering for pressure boosting systems the Helix range of high-pressure centrifugal pumps, which are fitted as standard with IE2 motors. Thus these pumps also already satisfy the requirements of the Directive, which come into effect from mid-211. The high-efficiency pump series Wilo-Stratos GIGA for the upper performance range in heating, cold-water and cooling applications is a completely new development. For the first time, glanded pumps are driven by EC motors with extremely low current consumption. The motor's energy efficiency is based on the new high-efficiency HED drive concept (HED High Efficiency Drive) from Wilo and even outclasses the limits of the upcoming efficiency class IE4 (acc. to IEC TS Ed.1) that is set to be the best. In addition, all specifications of the new EU Regulation, which are set to come into force on 16th June 211, 1st January 215 or 1st January 217 under the auspices of the European Ecological Design Directive on the energy efficiency of electric motors, have already been substantially exceeded. 1

9 Planning guide EEI classifications Energy efficiency class In the context of the Kyoto Agreement, European governments in particular are pursuing the goal of drastically reducing CO 2 emissions. Energy labelling, particularly for high-consumption household devices such as washing machines and refrigerators, is prescribed as an important control element for providing the end consumer with an aid for making decisions in favour of energy-saving appliances. Due to the fact that heating circulation pumps are among the biggest individual electricity consumers in household use because of their long running times, leading European heating pump manufacturers have voluntarily declared their intention of henceforth attaching energy labels to their heating pumps. This makes it possible for users and end consumers to recognise, on the basis of an already familiar classification system, whether a heating circulation pump in use is particularly energy-efficient. The classification of the energy efficiency of heating pumps is carried out by means of a technical measuring procedure, which provides the Energy Efficiency Index, EEI. The smaller the EEI, the less electrical energy the pump consumes and the more favourable the energy classification. Relative power consumption 18% 16% 14% 12% 1% 8% 6% 4% 2% % A B C D E F G Energy class Fig.: Comparison of the energy consumption rates of pumps with the same hydraulic output Energy class Energy Efficiency Index A EEI <.4 B.4 EEI <.6 C.6 EEI <.8 D.8 EEI < 1. E 1. EEI < 1.2 F 1.2 EEI < 1.4 G 1.4 EEI Table: Classification of the Energy Efficiency Index in 7 different energy categories. Fig.: Energy label for heating circulation pumps, Example: Energy class A The following tables list the corresponding energy class for all heating pumps to be labelled, which is incorporated in the energy label on the packaging. In accordance with the lettering system familiar from household appliances, A is the best possible and G is the worst possible of the energy classes. A comparison of hydraulically similar pumps with different energy classifications reveals that there is a difference of approximately 22% in terms of energy consumption between two sequentially numbered energy classes. Accordingly, an energy class A pump requires on average only around 33% of the electrical energy consumed by a class D pump. Even though the energy requirements of a class A pump are very high, high-efficiency energy class A pumps have in the meantime become available for use throughout the entire performance range from single-family houses to large buildings. 11

10 Planning guide Variant key, pump control Variant key for glanded pumps valid for variants of the following series: IPL, DPL, IL, DL, IPS, BL, IP-E, DP-E, IL-E, DL-E Variants Key Meaning Mechanical seal variants S1 Q1Q1X4GG for water-glycol mixtures with the following compositions: Glycol proportion of 2 to 4 vol.% and an operating temperature of 4 C to 12 C or glycol proportion > 4 to 5 vol.% and an operating temperature of -2 C to 12 C (see page 14) Housing variants Motor variants S2 AQ1VGG water-oil emulsions and water with oil components up to 9 C (see page 14) H1 H4 H5 K3 N EN-GJS-4-18-LT (formerly GGG 4.3) (shot graphite casting or spheroidal cast iron) Combination flanges PN6/PN1 for IPL; only for IPL 4, IPL 5 (145 rpm), IPL 4, IPL 5, IPL 65 (29 rpm) Max. operating pressure PN 16 (for IPL/DPL and IP_E/DP-E) Integrated PTC thermistors (3 x, tripping units as accessories) Version N with IEC standard motor (only IPL, DPL) Impeller variants L1 Impeller made of red brass RG = G-CuSn 1 Control variants R1 Electronically controlled pump without sensor (DDG) Pump control When Wilo pumps are operated with control devices or module accessories, the electrical operating conditions are to be complied with in accordance with VDE 16. When operating glandless and glanded pumps with brands of frequency converters other than those supplied by Wilo, output filters for reducing motor noise and for preventing harmful voltage peaks are to be used and the following limit values are to be complied with: Glandless pumps with P kw and glanded pumps with P kw rate of voltage rise du/dt < 5 V/μs voltage peaks û < 65 V For the noise reduction of glandless pump motors, it is recommended that sine filters (LC filters) are used rather than du/dt filters (RC filters). Glanded pumps with P 2 > 1.1 kw rate of voltage rise du/dt < 5 V/μs voltage peaks û < 85 V 12

11 Glandless premium high-efficiency pumps Wilo-Stratos PICO H[m] 6 5 Wilo-Stratos PICO >Accessories Page Screwed connections Adapter fittings , 25, 3/1-6 15, 25, 3/ Q[m³/ h] APPLIES TO EUROPEAN DIRECTIVE FOR ENERGY RELATED PRODUCTS TÜV certificate can be found at Construction Glandless circulation pump with threaded connection, blocking-current proof EC motor and integrated electronic performance control. Application All hot water heating systems, air-conditioning applications, industrial circulation systems. Technical data Fluid temperature +2 C to +11 C Mains connection 1~23 V, 5 Hz Protection class IP X4D Threaded connection Rp ½, Rp 1 and Rp 1¼ Max. operating pressure 1 bar Wilo-Stratos PICO Special features/product advantages Energy efficiency class A Maximum efficiency thanks to ECM technology High-efficiency pump especially for the single and two-family house and two to sixfamily house. Up to 9% electricity savings compared to old uncontrolled heating pumps Only 3 watts min. power consumption Pre-selectable control modes for optimum load adaption Δp-c (constant differential pressure), Δp-v (variable differential pressure) can be combined with the Dynamic Adapt control function (available from January 212) Automatic setback operation Integrated motor protection LC display displaying the current consumption in watts and the cumulative kilowatt hours Reset function for resetting the electricity meter or for resetting the settings to the factory settings (available from January 212) Ventilation routine for automaticventing of the rotor chamber Quick electrical connection with Wilo- Connector Very high starting torque for reliable starting Price group: W1 Type Pipe connection EEI Class Overall length Rated pressure Mains connection Gross weight Pieces per pallet Rp l PN m mm bar kg ] GBP Stratos PICO 25/1-4 1 A ~23 V, 5/6 Hz L 217. Stratos PICO 25/1-6 1 A ~23 V, 5/6 Hz L 219. Stratos PICO 25/ A ~23 V, 5/6 Hz L 26. Stratos PICO 25/ A ~23 V, 5/6 Hz L 213. Stratos PICO 3/1-4 1¼ A ~23 V, 5/6 Hz L 224. Stratos PICO 3/1-6 1¼ A ~23 V, 5/6 Hz L 226. Art no. 13

12 Glandless standard high-efficiency pumps Wilo-Yonos PICO H/m Wilo-Yonos PICO >Accessories Page Screwed connections Adapter fittings , 25, 3/1-4 15, 25, 3/1-6 Coming soon!,5 1, 1,5 2, 2,5 3, 3,5Q/m³/h APPLIES TO EUROPEAN DIRECTIVE FOR ENERGY RELATED PRODUCTS Construction Glandless circulation pump with threaded connection, blocking-current proof EC motor and integrated electronic performance control. Application All hot water heating systems, air-conditioning applications, industrial circulation systems. Technical data Fluid temperature -1 C to +95 C Mains connection 1~23 V, 5 Hz Wilo-Yonos PICO Protection class IP X2 D Threaded connection Rp ½, Rp 1 and Rp 1¼ Max. operating pressure 6 bar Special features/product advantages Energy efficiency class A Highest degrees of efficiency due to ECM technology High-efficiency pump especially for single and two-family houses, as well as for two to six-family houses Only 4 watts min. power consumption Pre-selectable control modes for optimum load adaptation >p-c (constant differential pressure), >p-v (variable differential pressure), Integrated motor protection LED display to adjust the setpoint and to show the current consumption in watts Ventilation function to vent the rotor chamber Quick electrical connection with Wilo-Connector Flexible installation due to compact design Very high starting torque for reliable starting Price group: W1 Type Pipe connection EEI Class Overall length Rated pressure Mains connection Gross weight Pieces per pallet Art no. Rp l PN m mm bar kg Yonos PICO 15/ ½ A ~23 V, 5/6 Hz Yonos PICO 15/ ½ A ~23 V, 5/6 Hz Yonos PICO 25/1-4 1 A ~23 V, 5/6 Hz Yonos PICO 25/ A ~23 V, 5/6 Hz Yonos PICO 25/1-6 1 A ~23 V, 5/6 Hz Yonos PICO 25/ A ~23 V, 5/6 Hz Yonos PICO 3/1-4 1¼ A ~23 V, 5/6 Hz Yonos PICO 3/1-6 1¼ A ~23 V, 5/6 Hz

13 Glandless standard high-efficiency pumps Wilo-Stratos ECO...-BMS H[m] , 3/1-5 Wilo-Stratos ECO-BMS >Accessories Page Screwed connections Adapter fittings ,5 1, 1,5 2, 2,5Q[m³/h] Construction Glandless circulation pump with threaded connection, EC motor with automatic power adjustment Application Hot-water heating systems of all kinds, industrial circulation systems Technical data Fluid temperature +15 C to +11 C (at max. ambient temperature +25 C) Mains connection 1~23 V, 5 Hz Wilo-Stratos ECO...-BMS Protection class IP 44 Threaded connection Rp 1 and Rp 1¼ Max. operating pressure 1 bar Special features/product advantages Energy efficiency class A Up to 8% electricity savings compared to uncontrolled circulation pumps High-efficiency pump especially for single and two-family houses, as well as for two to six-family houses Maximum efficiency thanks to ECM technology Very high starting torque for reliable starting Quick connection with spring clips BA connection: For connection to external monitoring units (e.g. building automation) Collective fault signal as potential-free contact, control input External Off, control input -1 V Only 5.8 W min. power consumption Standard thermal insulation for heating applications Price group: W1 Type Pipe connection EEI Class Overall length Rated pressure Mains connection Gross weight Pieces per pallet Rp l PN m mm bar kg ] GBP Stratos ECO 25/1-5-BMS 1 A ~23 V, 5 Hz L 351. Stratos ECO 3/1-5-BMS 1¼ A ~23 V, 5 Hz L 355. Art no. 15

14 Glandless premium high-efficiency pumps Wilo-Stratos H[m] (3,32,4,5)/1-1 25(3)/1-8 32/1-12 4/1-12 5/ /1-12 Wilo-Stratos 8(1)/1-12 >Accessories Page IR-Module, IR-Monitor 122 Screwed connections 124 Adapter fittings 127 IF-Modules (3)/1-6 3/1-12 4(5)/1-8 5/1-9 65/1-9 25(3)/ / Q[m³/h] APPLIES TO EUROPEAN DIRECTIVE FOR ENERGY RELATED PRODUCTS TÜV certificate can be found at Construction Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power adjustment. Application Hot-water heating systems of all kinds, airconditioning systems, closed cooling circuits, industrial circulation systems. Technical data Permissible temperature range -1 C to +11 C Mains connection 1~23 V, 5/6 Hz Protection class IP X4D Wilo-Stratos Screwed connection or flange connection (depending on type) Rp 1 to DN 1 Max. operating pressure, standard version: 6/1 bar or 6 bar (special version: 1 bar or 16 bar) Special features/product advantages Energy efficiency class A Highest degrees of efficiency due to ECM technology Up to 8% electricity savings compared to uncontrolled circulation pumps Front operation and access to the terminal space, variable installation positions, display independent of position Simple installation due to combination flanges PN 6/PN 1 (with DN 32 to DN 65) Can be used in cooling/air-conditioning systems without ambient temperature limits Pump housing with cataphoretic coating for the prevention of corrosion by condensation formation System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, CAN, LON, PLR etc. Remote operation via infrared interface (IR- Module/IR-Stick/IR-Monitor) Options Special versions for operating pressure PN 16 (at additional charge) Price group: W1 Type Pipe connection Overall length EEI Class Rated pressure Mains connection Gross weight Rp l PN m mm bar kg ] GBP Stratos 25/ A 1 1~23 V, 5/6 Hz L 462. Stratos 25/ A 1 1~23 V, 5/6 Hz L 5. Stratos 25/ A 1 1~23 V, 5/6 Hz L 524. Stratos 25/ A 1 1~23 V, 5/6 Hz L 53. Stratos 3/1-4 1¼ 18 A 1 1~23 V, 5/6 Hz L 498. Stratos 3/1-6 1¼ 18 A 1 1~23 V, 5/6 Hz L 52. Stratos 3/1-8 1¼ 18 A 1 1~23 V, 5/6 Hz L 556. Stratos 3/1-1 1¼ 18 A 1 1~23 V, 5/6 Hz L 58. Stratos 3/1-12 1¼ 18 A 1 1~23 V, 5/6 Hz L 793. Art no. 16

15 Glandless premium high-efficiency pumps Wilo-Stratos Wilo-Stratos Price group: W1 Type Nominal flange diameter Overall length EEI Class Rated pressure Mains connection Gross weight DN l PN m mm bar kg ] GBP Stratos 32/ A 6/1 1~23 V, 5/6 Hz L 62. Stratos 32/ A 6/1 1~23 V, 5/6 Hz L 895. Stratos 4/ A 6/1 1~23 V, 5/6 Hz L 735. Stratos 4/ A 6/1 1~23 V, 5/6 Hz L 92. Stratos 4/ A 6/1 1~23 V, 5/6 Hz L 684. Stratos 4/ A 6/1 1~23 V, 5/6 Hz L Stratos 5/ A 6/1 1~23 V, 5/6 Hz L Stratos 5/ A 6/1 1~23 V, 5/6 Hz L Stratos 5/ A 6/1 1~23 V, 5/6 Hz L 775. Stratos 5/ A 6/1 1~23 V, 5/6 Hz L 1 6. Stratos 65/ A 6/1 1~23 V, 5/6 Hz L Stratos 65/ A 6/1 1~23 V, 5/6 Hz L Stratos 8/ A 6 1~23 V, 5/6 Hz L Stratos 8/ A 1 1~23 V, 5/6 Hz L Stratos 1/ A 6 1~23 V, 5/6 Hz L Stratos 1/ A 1 1~23 V, 5/6 Hz L Art no. 17

16 Glandless premium high-efficiency pumps Wilo-Stratos-D H[m] /1-12 4/1-12 4(5)/1-8 5/1-12 5/1-9 Wilo-Stratos-D + 8/1-12 >Accessories Page IR-Module, IR-Monitor Screwed connections Adapter fittings IF-Modules / / Q[m³/h] Construction Glandless double circulation pump with flange connection, EC motor with automatic power adjustment Application Hot-water heating systems of all kinds, airconditioning systems, closed cooling circuits, industrial circulation systems Technical data Permissible temperature range -1 C to +11 C Mains connection 1~23 V, 5/6 Hz Protection class IP X4D Flange connection DN 32 to DN 8 Wilo-Stratos-D with BUS interface CAN Max. operating pressure, standard version: 6/1 bar or 6 bar (special version: 1 bar or 16 bar) Special features/product advantages Energy efficiency class A Highest degrees of efficiency due to ECM technology Up to 8% electricity savings compared to uncontrolled circulation pumps Front operation and access to the terminal space, variable installation positions, display independent of position Simple installation due to combination flanges PN 6/PN 1 (with DN 32 to DN 65) Can be used in cooling/air-conditioning systems without ambient temperature limits Pump housing with cataphoretic (cataphoretic) coating for the prevention of corrosion by condensation formation System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, LON, CAN, PLR etc. Remote operation via infrared interface (IR- Module/IR-Stick/IR-Monitor) Integratable dual pump management due to retrofit Stratos IF-Modules: - Main/standby mode with fault-dependent switchover - Efficiency-optimised peak-load operation Options Special versions for operating pressure PN 16 (at additional charge) Price group: W1 Type Nominal flange diameter Overall length EEI Class Rated pressure Mains connection Gross weight DN l PN m mm bar kg ] GBP Stratos-D 32/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 32/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 4/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 4/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 5/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 5/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 5/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 65/ A 6/1 1~23 V, 5/6 Hz L Stratos-D 8/ A 6 1~23 V, 5/6 Hz L Stratos-D 8/ A 1 1~23 V, 5/6 Hz L Art no. 18

17 Glandless automatic pumps Wilo-Smart H[m] 4 3 Wilo-Smart >Accessories Page Screwed connections Adapter fittings Thermal insulation shells Smart 15/6, 25/6, 25/6-RG, 3/6 Smart 15/4, 25/4-RG Smart-A 25/4, 3/4 2 1,5 1 1,5 2 2,5 3 Q[m³/h] Construction Glandless circulating pump with screwed connection and automatic power adjustment Application Hot-water heating systems of all kinds, industrial circulation systems Technical data Permissible temperature range +2 C to +95 C Mains connection 1~23 V, 5 Hz Protection class IP 42 Threaded connection Rp ½, 1, 1 ¼ Max. operating pressure 1 bar Wilo-Smart Special features/product advantages Energy efficiency class A (Smart A 25/4, 3/4) Up to 7% electricity cost savings compared to uncontrolled heating pumps Simple pipe connection due to the safe and practical wrench attachment point on the pump body. Safe electrical connection due to ergonomically optimised terminal box. Quick connection with spring clips. Simple operation. Factory setting suitable for 8% of all heating system requirements. Simple selection of the three pre-programmed control channels with the red button. The automatic controller of the Wilo-Smart prevents flow noise in the heating system and reduces electricity consumption. Operational reliability due to automatic deblocking function. A special bronze filter prevents particles from penetrating the motor compartment. Price group: W Type Pipe connection Overall length Rated pressure EEI Class Mains connection Gross weight Rp l PN m mm bar kg ] GBP Smart A 25/ A 1~23 V, 5 Hz L 65. Smart B B 1~23 V, 5 Hz L 68. Pieces per pallet Art no. 19

18 Glandless standard pumps Wilo-Star-RS H[m] Star-RS 15/6, 25/6, 3/6 Star-RS 15/4, 25/4, 3/4 Star-RS 25/2, 3/2 Star-RS 25/8, 3/8 Star-RS 25/7, 3/7 Wilo-Star-RS Q[m³/h] >Accessories Page Screwed connections Adapter fittings Thermal insulation shells Construction Glandless circulation pump with threaded connection. Preselectable speed stages for power adjustment Application Hot-water heating systems of all kinds, industrial circulation systems, cold water systems and air-conditioning systems Wilo-Star-RS Technical data Permissible temperature range -1 C to +11 C Mains connection 1~23 V, 5 Hz Protection class IP 44 Threaded connection Rp ½, Rp 1 or Rp 1¼ Max. operating pressure 1 bar Special features/product advantages Suitable for any installation position with horizontal shaft; terminal box in o'clock position Three preselectable speed stages for load adjustment Easy and safe installation due to practical wrench attachment point on pump body Simplified electrical installation due to terminal box with removable threaded cable connection that can be used on both sides; Quick connection with spring clips Price group: W Type Pipe connection EEI Class Overall length Rated pressure Mains connection Gross weight Pieces per pallet Rp l PN m mm bar kg ] GBP Star-RS 15/4 ½ B ~23 V, 5 Hz L 88. Star-RS 15/6 ½ C ~23 V, 5 Hz L 17. Star-RS 25/2 1 C ~23 V, 5 Hz L 143. Star-RS 25/4 1 B ~23 V, 5 Hz L 144. Star-RS 25/6 1 C ~23 V, 5 Hz L 147. Star-RS 3/2 1¼ C ~23 V, 5 Hz L 148. Star-RS 3/4 1¼ B ~23 V, 5 Hz L 15. Star-RS 3/6 1¼ C ~23 V, 5 Hz L 176. Art no. 2

19 Glandless standard pumps Wilo-Star-RSD H[m] 5 4 Wilo-Star-RSD >Accessories Page + Screwed connections Adapter fittings Star-RSD 3/6 3 Star-RSD 3/ Q[m³/h] Construction Glandless circulation double pump with threaded connection; Preselectable speed stages for power adjustment Application Hot-water heating systems of all kinds, industrial circulating systems, cold-water systems and air-conditioning systems Wilo-Star-RSD Technical data Permissible temperature range -1 C to +11 C Mains connection 1~23 V, 5 Hz Protection class IP 44 Threaded connection Rp 1¼ Max. operating pressure 1 bar Special features/product advantages Double pump for single or parallel operation Suitable for any installation position with horizontal shaft; terminal box in o'clock position Increased reliability in individual operation due to the constant availability of a standby unit ready for operation Price group: W Type Pipe connection Overall length EEI Class Rated pressure Mains connection Gross weight Rp l PN m mm bar kg ] GBP Star-RSD 3/4 1¼ 18 D 1 1~23 V, 5 Hz L 367. Star-RSD 3/6 1¼ 18 D 1 1~23 V, 5 Hz L 387. Art no. 21

20 Glandless standard pumps Wilo-TOP-S H[m] /13 25(3)/5 25(3)/1 25(3)/7 3/4 5/15 4/15 4/1 1 4/7 4/4 5/4 65/13 2 5/1 65/7 5/7 65/1 3 65/15 4 8/7 8/1 1/1 5 6 Wilo-TOP-S >Accessories Page Switching plugs Screwed connections Adapter fittings Wilo tripping units SK 62N/SK 622N Wilo-Protect Module-C /15 8/2 Q[m³/h] Construction Glandless circulation pump with screwed connection or flange connection. Application Hot-water heating systems of all kinds, industrial circulation systems, air-conditioning systems and closed cooling circuits Technical data Permitted temperature range -2 C to +13 C, for short periods (2 h) up to +14 C (TOP-S 25/13, 8/15, 8/2 and pumps with Wilo-Protect-Module: -2 C to +11 C) Wilo-TOP-S Mains connection: - 1~23 V, 5 Hz (depending on type) - 3~23 V, 5 Hz (with optional switching plug) - 3~4 V, 5 Hz Protection class IP X4D Screwed connection or flange connection (depending on type) Rp 1 to DN 1 Max. operating pressure, standard version: 6/1 bar or 6 bar (special version: 1 bar or 16 bar) Special features/product advantages Can be used in heating systems and in cooling/air-conditioning systems from -2 C to +13 C (TOP-S 25/13, TOP-S 8/15 and TOP-S 8/2 from -2 C to +11 C) Pump housing with cataphoretic coating for the prevention of corrosion by condensation formation Manual power adjustment with 3 speed stages Simple installation due to combination flange PN 6/PN 1 (for DN 4 to DN 65) Options Special version for operating pressure PN 16 (at additional charge) Version for special voltages on request. Price group: W2 Type Pipe connection Overall length EEI Class Rated pressure Mains connection Gross weight Rp l PN m mm bar kg ] GBP TOP-S 25/ D 1 1~23 V, 5 Hz L 259. TOP-S 25/ D 1 3~4/23 V, 5 Hz L 286. TOP-S 25/ D 1 1~23 V, 5 Hz L 32. TOP-S 25/ D 1 3~4/23 V, 5 Hz L 334. TOP-S 25/ D 1 1~23 V, 5 Hz C 367. TOP-S 25/ D 1 3~4/23 V, 5 Hz C 38. TOP-S 25/ F 1 1~23 V, 5 Hz C 395. TOP-S 25/ F 1 3~4/23 V, 5 Hz C 412. TOP-S 3/4 1¼ 18 D 1 1~23 V, 5 Hz L 276. TOP-S 3/4 1¼ 18 D 1 3~4/23 V, 5 Hz L 289. TOP-S 3/5 1¼ 18 D 1 1~23 V, 5 Hz L 281. TOP-S 3/5 1¼ 18 D 1 3~4/23 V, 5 Hz L 313. TOP-S 3/7 1¼ 18 D 1 1~23 V, 5 Hz L 34. TOP-S 3/7 1¼ 18 D 1 3~4/23 V, 5 Hz L 342. TOP-S 3/1 1¼ 18 D 1 1~23 V, 5 Hz L 47. TOP-S 3/1 1¼ 18 D 1 3~4/23 V, 5 Hz L 478. Art no. 22

21 Glandless standard pumps Wilo-TOP-S Wilo-TOP-S Price group: W2 Type Nominal flange diameter Overall length EEI Class Rated pressure Mains connection Gross weight DN l PN m mm bar kg ] GBP TOP-S 4/ D 6/1 1~23 V, 5 Hz L 57. TOP-S 4/ D 6/1 3~4/23 V, 5 Hz L 59. TOP-S 4/ D 6/1 1~23 V, 5 Hz L 652. TOP-S 4/ C 6/1 3~4/23 V, 5 Hz L 655. TOP-S 4/ D 6/1 1~23 V, 5 Hz L 798. TOP-S 4/ C 6/1 3~4/23 V, 5 Hz L 752. TOP-S 4/ D 6/1 1~23 V, 5 Hz L 93. TOP-S 4/ D 6/1 3~4/23 V, 5 Hz L 835. TOP-S 5/ D 6/1 1~23 V, 5 Hz L 731. TOP-S 5/ D 6/1 3~4/23 V, 5 Hz L 734. TOP-S 5/ C 6/1 1~23 V, 5 Hz L 877. TOP-S 5/ C 6/1 3~4/23 V, 5 Hz L 766. TOP-S 5/ C 6/1 1~23 V, 5 Hz L 976. TOP-S 5/ C 6/1 3~4/23 V, 5 Hz L 878. TOP-S 5/ C 6/1 3~4/23 V, 5 Hz L TOP-S 65/ C 6/1 1~23 V, 5 Hz L TOP-S 65/ C 6/1 3~4/23 V, 5 Hz L 914. TOP-S 65/ C 6/1 1~23 V, 5 Hz L TOP-S 65/ C 6/1 3~4/23 V, 5 Hz L 958. TOP-S 65/ C 6/1 3~4/23 V, 5 Hz L TOP-S 65/ C 6/1 3~4/23 V, 5 Hz L TOP-S 8/ C 6 1~23 V, 5 Hz L TOP-S 8/ C 6 3~4/23 V, 5 Hz L TOP-S 8/ C 1 3~4/23 V, 5 Hz L TOP-S 8/ C 6 3~4/23 V, 5 Hz L TOP-S 8/ C 1 3~4/23 V, 5 Hz L TOP-S 8/ C 6 3~4 V, 5 Hz L TOP-S 8/ C 1 3~4 V, 5 Hz L TOP-S 8/ C 6 3~4 V, 5 Hz L TOP-S 8/ C 1 3~4 V, 5 Hz L TOP-S 1/ C 6 3~4/23 V, 5 Hz L TOP-S 1/ C 1 3~4/23 V, 5 Hz L Art no. 23

22 Glandless standard pumps Wilo-TOP-SD H[m] /5 32/7 32/ /3 4/15 4/7 4/1 5/7 65/1 5/1 5/15 65/13 65/15 Wilo-TOP-SD + 8/1 8/15 8/ Q[m³/h] >Accessories Page Switching plugs Brackets for pump fixation Screwed connections Adapter fittings Wilo tripping units SK 62N/SK 622N Wilo-Protect Module-C Blind plates Construction Glandless double circulation pump with flange connection (TOP-SD 3/5 with screwed connection). Application Hot-water heating systems of all kinds, industrial circulation systems, air-conditioning systems and closed cooling circuits Technical data Permitted temperature range -2 C to +13 C, for short periods (2 h) to +14 C (TOP-SD 8/15, TOP-SD 8/2 and pumps with Wilo- Protect-Module: -2 C to +11 C) Wilo-TOP-SD Mains connection: - 1~23 V, 5 Hz (depending on type) - 3~23 V, 5 Hz (with optional switching plug) - 3~4 V, 5 Hz Protection class IP X4D Screwed connection or flange connection (depending on type) Rp 1¼ to DN 8 Max. operating pressure, standard version: 6/1 bar or 6 bar (special version: 1 bar or 16 bar) Special features/product advantages Can be used in heating systems and in cooling/air-conditioning systems from -2 C to +13 C (TOP-SD 8/15 and TOP-SD 8/2 from - 2 C to +11 C) Double pump for main/standby mode or parallel operation Manual power adjustment with 3 speed stages Pump housing with cataphoretic coating for the prevention of corrosion by condensation formation Simple installation due to combination flange PN 6/PN 1 (for DN 32 to DN 65) Options Special versions for operating pressure PN 16 (at additional charge) Versions for special voltages on request Price group: W2 Type Pipe connection Overall length EEI Class Rated pressure Mains connection Gross weight Rp l PN m mm bar kg ] GBP TOP-SD 3/5 1¼ 18 D 1 1~23 V, 5 Hz L 587. TOP-SD 3/5 1¼ 18 D 1 3~4/23 V, 5 Hz L 65. Art no. Wilo-TOP-SD Price group: W2 Type Nominal flange diameter Overall length EEI Class Rated pressure Mains connection Gross weight DN l PN m mm bar kg ] GBP TOP-SD 32/ E 6/1 1~23 V, 5 Hz L 817. TOP-SD 32/ D 6/1 3~4/23 V, 5 Hz L 841. TOP-SD 32/ D 6/1 1~23 V, 5 Hz L 86. TOP-SD 32/ D 6/1 3~4/23 V, 5 Hz L 945. TOP-SD 4/ E 6/1 1~23 V, 5 Hz L TOP-SD 4/ D 6/1 3~4/23 V, 5 Hz L 1 2. TOP-SD 4/ D 6/1 1~23 V, 5 Hz L TOP-SD 4/ D 6/1 3~4/23 V, 5 Hz L TOP-SD 4/ D 6/1 1~23 V, 5 Hz L Art no. 24

23 Glandless standard pumps Wilo-TOP-SD Wilo-TOP-SD Price group: W2 Type Nominal flange diameter Overall length EEI Class Rated pressure Mains connection Gross weight TOP-SD 4/ C 6/1 3~4/23 V, 5 Hz L TOP-SD 4/ E 6/1 1~23 V, 5 Hz L TOP-SD 4/ D 6/1 3~4/23 V, 5 Hz L TOP-SD 5/ D 6/1 1~23 V, 5 Hz L TOP-SD 5/ C 6/1 3~4/23 V, 5 Hz L TOP-SD 5/ D 6/1 1~23 V, 5 Hz L 2 8. TOP-SD 5/ D 6/1 3~4/23 V, 5 Hz L TOP-SD 5/ D 6/1 3~4/23 V, 5 Hz L TOP-SD 65/ D 6/1 1~23 V, 5 Hz L TOP-SD 65/ D 6/1 3~4/23 V, 5 Hz L TOP-SD 65/ D 6/1 3~4/23 V, 5 Hz L TOP-SD 65/ D 6/1 3~4/23 V, 5 Hz L TOP-SD 8/ D 6 1~23 V, 5 Hz L TOP-SD 8/ D 6 3~4/23 V, 5 Hz L TOP-SD 8/ D 1 3~4/23 V, 5 Hz L TOP-SD 8/ C 6 3~4 V, 5 Hz L TOP-SD 8/ C 1 3~4 V, 5 Hz L TOP-SD 8/ C 6 3~4 V, 5 Hz L TOP-SD 8/ C 1 3~4 V, 5 Hz L Art no. DN l PN m mm bar kg ] GBP 25

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

Heating, Air-conditioning, Cooling

Heating, Air-conditioning, Cooling Catalogue Building Services Heating, Air-conditioning, Cooling Pumps, pump systems and accessories for heating, secondary hot water, air-conditioning and cooling International edition 2011/2012-50 Hz APPLIES

More information

Replacement Guide Heating

Replacement Guide Heating Replacement Guide Heating Wilo Circulators for Heating and Secondary Hot Water Circulation ab 1975 September 2006 Energy efficiency class A. Also for one- and two-family homes. Up to 80 % power savings.*

More information

Simple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos. Information for installers

Simple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos. Information for installers Simple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos Information for installers 2 ErP Directive Everyone's talking about saving electricity We take action Advantages

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

Catalogue Wilo- Stratos PARA

Catalogue Wilo- Stratos PARA Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm] Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Wilo Building Services - Price Book

Wilo Building Services - Price Book Pioneering for You 2016 - United States - 60 Hz. Wilo - Price Book Pumps and pump systems for HVAC, pressure boosting, water supply and sump & sewage. Effective - January 1, 2016 20-57-002-1215 FSA-066

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

The right partner for your project. Heating, ventilation and air-conditioning

The right partner for your project. Heating, ventilation and air-conditioning Our technology. Your success. Pumps n Valves n Service The right partner for your project. Heating, ventilation and air-conditioning 02 Introduction Always the right solution It is not only large projects

More information

Pumps n Valves n Service. The right partner for your project. Heating, ventilation and air-conditioning

Pumps n Valves n Service. The right partner for your project. Heating, ventilation and air-conditioning Pumps n Valves n Service The right partner for your project. Heating, ventilation and air-conditioning 02 Introduction Always the right solution It is not only large projects that place high demands on

More information

OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1.

OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1. Table of Contents 1. Purpose of the guidelines and disclaimer... 2 1.1. The Regulations... 2 2. Scope... 2 3. Historic developments... 4 4. Scope and Requirements... 5 4.1. Scope... 5 4.2. Requirements...

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Laing industrial pumps

Laing industrial pumps Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right

More information

How To Pump A Pump

How To Pump A Pump Multistage Pumps P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series MP with smaller

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. SANITARY & WASTE WATER PUMPING SYSTEMS Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. Wallace Pumps solve all those waste disposal problems, big or small, with

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

AMTRON E-30 Compact heat and cooling meter

AMTRON E-30 Compact heat and cooling meter AMTRON E-30 Compact heat and cooling meter Application The compact AMTRON E-30 meter is used for energy consumption measurements for heating and cooling applications in small premises such as apartments,

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force

More information

High-efficient gas boiler CompactGas

High-efficient gas boiler CompactGas High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard

More information

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Pioneering for You. Industry Range Guide. Editie 2014/2015

Pioneering for You. Industry Range Guide. Editie 2014/2015 Pioneering for You Industry Range Guide Editie 014/01 Industry Range Guide World Leading. WILO SE, with headquarters in Dortmund, is one of the world s leading manufacturers of pumps and pump systems for

More information

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

AC2EC - Replacement made easy New EC motor design Compact and efficient "AC2EC" - Replacement made easy New EC motor design Compact and efficient The efficiency of the fans used is a central issue in ventilation and airconditioning technology. This is encouraged not only by

More information

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET FOR IMMEDIATE RELEASE No. 2387 Product & Catalogue Inquiries: Media Contact Naoto Shimada Travis Woodward Nakatsugawa Works Public Relations Department Photovoltaic Power System Business Center Mitsubishi

More information

SISTO-16TWA/HWA/DLU. Type Series Booklet

SISTO-16TWA/HWA/DLU. Type Series Booklet Diaphragm Valve SISTO-16TWA/HWA/DLU PN16 DN 15-200 Maintenance-free Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet SISTO-16TWA/HWA/DLU All rights reserved. The contents

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

The conditions below apply to the curves shown on the following pages.

The conditions below apply to the curves shown on the following pages. GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves

More information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

Electric Coolant Pumps. Always at the Correct Temperature

Electric Coolant Pumps. Always at the Correct Temperature Electric Coolant Pumps Always at the Correct Temperature Electric coolant pumps Conventional pumps for engine cooling are driven by toothed belts and hence their output is coupled to engine RPM. Coolant

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

NXL Series Inverters. HVAC Inverters made simple

NXL Series Inverters. HVAC Inverters made simple NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011 Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...

More information

EC medium pressure axial fans. The effi cient system solution.

EC medium pressure axial fans. The effi cient system solution. EC medium pressure axial fans. The effi cient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly effi cient GreenTech EC technology is now available for

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information