Spring-Flex Hangers Series SH/RSH

Size: px
Start display at page:

Download "Spring-Flex Hangers Series SH/RSH"

Transcription

1 Bulletin No. SH/14 Spring-Flex Hangers Series SH/RSH Two Basic Designs Effective Isolation of Noise and Vibration Loads to 5,000 pounds Static Deflections to 5 inches Quickly and Easily Installed Color Coded Springs for Easy Identification Typical Applications Piping Air Handling Units Fans Duct Work Suspended Ceilings Vibration Mountings & Controls, Inc. P.O.Box 270, Bloomingdale, New Jersey 07403

2 Spring-Flex Hangers Series SH/RSH VMC Spring-Flex hangers are offered in two basic designs Series SH spring hangers designed to isolate low frequency vibrations and Series RSH combination spring in series with a neoprene element designed for critical locations where it is important to isolate both noise & vibration. VMC Spring Flex hangers are necessary to prevent vibration in piping and equipment from being transmitted to the building structure. We recommend that Spring Flex hangers be used for all suspended piping in equipment rooms or 50 ft from vibrating equipment, whichever is greater. To avoid reducing the effectiveness of the equipment isolators, at least 3 of the first hangers from the equipment should provide the same deflection as the equipment isolators. The remaining hangers should be type SH or RSH with.75 inch deflection. In order to reduce installation labor costs, Vibration Mountings and Controls has designed a revolutionary line of hangers that incorporate a clevis or trapeze hanger combined with vibration isolation in one product. See our series CIH, CIR, TIH or TIR for details. To prevent load transfer to the equipment flanges when the piping system is filled, VMC has designed pre-compressed and pre-positioning hangers which should be installed at the first three hanger locations adjacent to the equipment. These designs insure that the weight of the piping is kept off isolated equipment in order to maintain alignment, protect flexible connectors, and keep equipment isolators from becoming overloaded. When used in seismic applications, VMC hangers should be used in conjunction with Series SCR seismic cable restraints which restrain suspended piping and equipment during an earthquake. 2

3 SERIES SH 1" deflection TYPE & SIZE A B C D E F SHS-6 thru 10 2¹ ₄" 2³ ₄" ⁹ ₁₆" 4¹ ₂" 2⁷ ₈" ³ ₈" SHS-11 thru 18 SH-19 thru 32 SHW-200 thru 1628 SHW /1625/1628 2¹ ₄" 3" ¹³ ₁₆" 5¹ ₂" 3¹ ₈" ⁵ ₈" 3" 3¹ ₄" 1¹ ₄" 7" 4³ ₄" ³ ₄" 4" 4³ ₄" 1¹ ₂" 8³ ₁₆" 4⁵ ₈" 1" 5" 10" 1¹ ₄" 12" 6⁵ ₈" 1¹ ₈" VMC series SH Spring Flex hangers provide excellent vibration isolation for suspended piping and equipment. They incorporate a color coded steel spring for ease of identification in the field. Load ranges from 21 lb to 5000 lb and up to 5 inches of static deflection offer a wide variety of choices to insure proper support. Series SH-30A offers all ofthe above features plus the capability for the lower hanger rod to swing approximately 30 to compensate for rod misalignment. The 30 misalignment capability insures that the rod does not short circuit the hanger by coming in contact with the hanger box. When isolating ductwork and suspended ceilings, our Series SHSC can be utilized. These hangers incorporate eyebolt hardware to accommodate duct strap connections. How To Specify VMC Series SH Spring Hangers Spring-Flex hangers shall consist of a color-coded steel spring with a neoprene and steel washer which will properly distribute the load on the spring. For 30 misalignment capability, spring diameters and hanger box lower hole sizes shall be of sufficient size to permit the hanger rod to swing approximately 30 before contacting the box. Springs shall have a minimum additional travel to solid equal to 50% of the rated deflection. Hangers which are to be used with flat iron duct straps will be provided with eye bolts on both ends. Spring-Flex hangers shall be Series SH, SH-30A, as manufactured by Vibration Mountings and Controls, Inc. & SIZE in. lbs. lbs./in. COLOR SHS BLUE SHS BLACK SHS RED SHS GREEN SHS GRAY SHS BLUE SHS ORANGE SHS BROWN SHS BLACK SHS YELLOW SHS RED SHS GREEN SH PINK SH BLACK SH BLUE SH YELLOW SH BROWN SH RED SH PURPLE SH ORANGE SH GREEN SH GRAY SH WHlTE SHW BLUE SHW BLACK SHW RED SHW GREEN SHW YELLOW SHW GRAY SHW GRAY/RED SHW GRAY/GREEN SHW GRAY SHW GRAY/RED SHW GRAY/GREEN 3

4 SERIES SH 1¹ ₂" & 2" deflection TYPE & SIZE A B C D E F SHM-100 thru 109 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 6¹ ₂" ⁷ ₈" SH-81 thru 87 3" 3³ ₄" 1¹ ₂" 8¹ ₄" 4⁷ ₈" ³ ₄" SH-401 thru 410 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 6" ⁷ ₈" SHD-50 thru 553 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 7" ⁷ ₈" & SIZE in. lbs. lbs./in. COLOR SHM BROWN SHM ORANGE SHM-I GREEN SHM RED SHM BLACK SHM-I WHITE SHM GRAY SHM BLUE SHM YELLOW SHM PINK SH BLUE SH ORANGE SH PURPLE SH YELLOW SH GREY SH RED SH GREEN SH BLUE SH YELLOW SH BLACK SH PURPLE SH BROWN SH RED SH ORANGE SHD BLUE SHD BLACK SHD BLACK/BLUE SHD RED SHD RED/BLUE SHD RED/BLACK SHD GREEN SHD GREEN/BLUE SHD GREEN/BLACK SHD GREEN/RED SHD GRAY/BLACK SHD GRAY/RED SHD GRAY/GREEN 4

5 SERIES SH 3" & 5" deflection TYPE & SIZE A B C D E F SH-801 thru 805 4¹ ₂" 5¹ ₂" 1" 10" 8¹ ₂" ³ ₄" SH-806 thru 808 6" 7" 1" 13¹ ₂" 10" ⁷ ₈" SH-809/810 6" 7" 1" 13¹ ₂" 10³ ₄" ⁷ ₈" SH-821 thru 823 6" 7" 1" 13¹ ₂" 10³ ₄" ⁷ ₈" SH-824 thru 826 6" 7" 1" 13¹ ₂" 11³ ₄" ⁷ ₈" SH-827 thru 830 7" 8¹ ₂" 1³ ₁₆" 16" 13¹ ₂" 1" SH-831/832 7" 8¹ ₂" 1³ ₁₆" 16" 14" 1" & SIZE in. lbs. lbs.in. COLOR SH GRAY SH PINK SH BROWN SH BLUE SH RED SH WHITE SH GREEN SH BLACK SH YELLOW SH PURPLE SH ORANGE SH GRAY SH PINK SH BROWN SH BLUE SH RED SH WHITE SH GREEN SH BLACK SH YELLOW SH PURPLE SH ORANGE 5

6 SERIES SH 30A 1"/ 1¹ ₂" / 2" deflection & SIZE in. lbs. lbs.in. COLOR 6 TYPE & SIZE A B C D E F SH-30A-6 thru 10 SH-30A-11 thru 16 SH-30A-92 thru 99 SH-30A-6W thru 16W SH-30A-20W/25W 2¹ ₄" 2³ ₄" ⁹ ₁₆" 4¹ ₂" 2⁷ ₈" ³ ₈" 2¹ ₄" 3" ¹³ ₁₆" 5¹ ₂" 3¹ ₈" ⁵ ₈" 3" 3³ ₄" 1¹ ₂" 8¹ ₄" 4³ ₈" ³ ₄" 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 4⁵ ₈" 1" 4¹ ₂" 5³ ₈" 1³ ₁₆" 12³ ₈" 6" 1" SHM-30A-101 thru 109 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 6¹ ₈" ⁷ ₈" SH-30A " 1 1 2" 8 1 4" 4 7 8" 3 4" SH-30A " " " 6 ⁷ ₈" SHD-30A-50 thru 55 4¹ ₂" 5" 1¹ ₂" 10³ ¹⁶ " 7" ⁷ ₈ Large bottom hole ensures that rod can swing 30 to prevent metal to metal contact SH-30A BLUE SH-30A BLACK SH-30A RED SH-30A GREEN SH-30A GRAY SH-30A BLUE SH-30A ORANGE SH-30A BROWN SH-30A BLACK SH-30A YELLOW SH-30A BROWN SH-30A ORANGE SH-30A GREEN SH-30A RED SH-30A BLACK SH-30A WHITE SH-30A GRAY SH-30A BLUE SH-30A-6W RED SH-30A-1OW GREEN SH-30A-13W YELLOW SH-30A-16W GRAY SH-30A-20W BROWN SH-30A-25W ORANGE SHM-30A BROWN SHM-30A ORANGE SHM-30A GREEN SHM-30A RED SHM-30A BLACK SHM-30A WHITE SHM-30A GRAY SHM-30A BLUE SHM-30A YELLOW SHM-30A PINK SH-30A BLUE SH-30A ORANGE SH-30A PURPLE SH-30A YELLOW SH-30A GRAY SH-30A RED SH-30A GREEN SH-30A BLUE SH-30A YELLOW SH-30A BLACK SH-30A PURPLE SH-30A BROWN SH-30A RED SH-30A ORANGE SHD-30A BLUE SHD-30A BLACK SHD-30A RED SHD-30A GREEN SHD-30A GRAY

7 SERIES SHP 1" & 2" deflection TYPE & SIZE A B C D E F G SHSP-11 thru 18 SHP-19 thru 32 SHWP-200 thru 1000 SHWP-1600 thru 1628 SHWP thru " 3³ ₄" 1¹ ₄" 7" 3¹ ₈" 4¹ ₄" ⁵ ₈" 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 4⁷ ₈" 6⁷ ₈" ³ ₄" 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 4⁷ ₈" 6⁷ ₈" 1" 4¹ ₂" 5" 1¹ ₂" 10³ ₁₆" 4⁷ ₈" 6¹ ₄" 1" 5" 10" 1¹ ₄" 12" 9¹ ₂" 6⁵ ₈" 1¹ ₈" SHDP-50 thru 553 4" 4³ ₄" 1¹ ₂" 12³ ₈" 7" 8¹ ₄" ⁷ ₈" To prevent load transfer to the equipment flanges when the piping system is filled, VMC has designed pre-positioning (Series SHP) and precompressed (Series SHPR) hangers which should be installed at the first three hanger locations adjacent to the equipment. Series SHP incorporates a load bearing plate within the hanger box which keeps suspended piping at a fixed elevation during installation and start-up. Once the system is filled, the load is transferred from the plate to the spring insuring minimal movement in the piping. This design insures that the weight of the piping is kept off isolated equipment in order to maintain alignment, protect flexible connectors, and keep equipment isolators from becoming overloaded. Series SHP is capable of supporting loads up to 5000 lb and offers up to 2 inches of static deflection. INSTALLATION INSTRUCTION SERIES SHP AND RSHP HANGERS 1. Hangers are inserted in the hanger rods, or series SHP may be fastened directly to the structure. For best results, hangers should be located near the ceiling. 2. Piping or equipment should be hung at its proper elevation by inserting threaded rod up through the spring and suspended from the plate supplied in the hanger box. This plate is designed to maintain suspended equipment and piping at a fixed elevation during installation regardless of load changes. 3. The adjustment nut is provided to transfer the load to the spring after the piping system has been filled with water or the equipment is totally installed and level. 4. Turn the adjusting nut clockwise one complete turn on each hanger until the load is transferred from the supporting plate to the spring. How To Specify VMC Type SHP/RSHP Hangers Spring-Flex hangers shall consist of color-coded steel spring in series with a neoprene element molded in specific colors for proper identification of rated load capacity. Hanger design shall incorporate a means for supporting the suspended equipment or piping at a fixed elevation during installation regardless of load changes as well as a means for transferring the load to the spring. Spring-Flex hangers shall be series RSHP or SHP (spring only) positioning hangers as manufactured by Vibration Mountings and Controls, Inc. & SIZE in. lbs. lbs.in. COLOR SHSP BLUE SHSP ORANGE SHSP BROWN SHSP BLACK SHSP YELLOW SHSP RED SHSP GREEN SHSP PINK SHSP BLACK SHSP BLUE SHSP YELLOW SHSP BROWN SHSP RED SHSP PURPLE SHSP ORANGE SHSP GREEN SHSP GRAY SHSP WHITE SHWP BLUE SHWP BLACK SHWP RED SHWP GREEN SHWP ELLOW SHWP GRAY SHWP GRAY/BLUE SHWP GRAY/GREEN SHWP GRAY SHWP GRAY/RED SHWP GRAY/GREEN SHDP BLUE SHDP BLACK SHDP BLACK/BLUE SHDP RED SHDP RED/BLUE SHDP RED/BLACK SHDP GREEN SHDP GREEN/BLUE SHDP GREEN/BLACK SHDP GREEN/RED SHDP GRAY/BLACK SHDP GRAY/RED SHDP GRAY/GREEN 7

8 SERIES RSH 1" deflection TYPE & SIZE A B D E F G RSHS-6 thru 10 RSHS-11 thru 18 RSH-19 thru 32 RSHW-200 thru 1000 RSHW-1300 thru ¹ ₄" 2³ ₄" 5¹ ₄" 2⁷ ₈" ¹⁵ ₁₆" ³ ₈" 3" 3¹ ₄" 7" 3" 1¹ ₂" ⁵ ₈" 3" 3³ ₄" 8¹ ₄" 4³ ₈" 2¹ ₈" ³ ₄" 4¹ ₂" 5" 10³ ₁₆" 4⁵ ₈" 2¹ ₈" 1" 4¹ ₂" 5" 10³ ₁₆" 4⁵ ₈" 2¹ ₈" 1" RSHW thru " 11" 16" 6¹ ₂" 4" 1¹ ₈" VMC Series RSH Spring Flex hangers provide optimum vibration isolation for suspended piping and equipment. They incorporate a color coded steel spring in series with a neoprene rubber element. This combination is excellent for critical applications where it is important to isolate both vibration and structure-borne noise. Load ranges from 21 lb to 5000 Ib., and up to 5 inches of static deflection offer a wide variety of choices to insure proper support. Series RSH-30A offers all of the above features plus the capability for the lower hanger rod to swing approximately 30 to compensate for rod misalignment. The 30 misalignment capability insures that the rod does not short circuit the hanger by coming in contact with the hanger box. When isolating ductwork and suspended ceilings, our Series RSHSC can be utilized. These hangers incorporate eyebolt hardware to accommodate duct strap connections. How To Specify VMC Series RSH Hangers Spring-Flex hangers shall consist of a steel spring in series with a.2 inch (minimum) deflection neoprene element. Springs shall be color coded, and elastomer element molded in specific colors for proper identification of rated load capacity. Springs shall have a minimum additional travel to solid equal to 50% of the rated deflection. Pipe isolators shall have spring diameters and hanger box lower hole sizes of sufficient size to permit the hanger rod to swing approximately 30 before contacting the box. Hangers which are to be used with flat iron duct straps will be provided with eye bolts on both ends. Spring-Flex hangers shall be series RSH/RSH30A as manufactured by Vibration Mountings and Controls, Inc. Hangers with eyebolts to be type RSHSC/RSHSC-30A as manufactured by Vibration Mountings and Controls, Inc. & SIZE in. lbs. lbs.in. COLOR RSHS BLUE RSHS BLACK RSHS RED RSHS GREEN RSHS GRAY RSHS BLUE RSHS ORANGE RSHS BROWN RSHS BLACK RSHS-l YELLOW RSHS RED RSHS GREEN RSH PINK RSH BLACK RSH BLUE RSH YELLOW RSH BROWN RSH RED RSH PURPLE RSH ORANGE RSH GREEN RSH GRAY RSH WHITE RSHW BLUE RSHW BLACK RSHW RED RSHW GREEN RSHW YELLOW RSHW GRAY RSHW GRAY/RED RSHW GRAY/GREEN RSHW GRAY RSHW GRAY/RED RSHW GRAY/GREEN 8

9 SERIES RSH 1¹ ₂" & 2" deflection TYPE & SIZE A B D E F G RSHM-100 thru 106 4" 4³ ₄" 12³ ₈" 6¹ ₄" 2¹ ₈" 1" RSHM-107 thru 109 4" 4³ ₄" 12³ ₈" 6¹ ₄" 2¹ ₈" 1" RSH " 5" " 43 4" 21 8" 3 4" RSH " 4 3 4" " 5 7 8" 2 1 8" 1" RSHD-50 thru 530 4" 4³ ₄" 12³ ₈" 7" 2¹ ₈" 1" RSHD-531 thru 533 4" 4³ ₄" 12³ ₈" 7" 2¹ ₈" 1" & SIZE in. lbs. lbs.in. COLOR RSHM BROWN RSHM ORANGE RSHM GREEN RSHM RED RSHM BLACK RSHM WHITE RSHM GRAY RSHM BLUE RSHM YELLOW RSHM PINK RSH BLUE RSH ORANGE RSH PURPLE RSH YELLOW RSH GRAY RSH RED RSH GREEN RSH BLUE RSH YELLOW RSH BLACK RSH PURPLE RSH BROWN RSH RED RSH ORANGE RSHD BLUE RSHD BLACK RSHD BLACK/BLUE RSHD RED RSHD RED/BLUE RSHD RED/BLACK RSHD GREEN RSHD GREEN/BLUE RSHD GREEN/BLACK RSHD GREEN/RED RSHD GRAY/BLACK RSHD GRAY/RED RSHD GRAY/GREEN 9

10 SERIES RSH 3" & 5" deflection (mm) TYPE & SIZE A B D E F G RSH-801 thru 805 4¹ ₂" 5¹ ₂" 13" 8¹ ₂" 2" ³ ₄" RSH-806 thru 808 6" 7" 15¹ ₂" 10" 2¹ ₄" ⁷ ₈" RSH-809/810 6" 7" 15¹ ₂" 10³ ₄" 2¹ ₄" ⁷ ₈" RSH-821 thru 823 6" 7" 15¹ ₂" 10³ 4" 2" ⁷ ₈" RSH-824 thru 826 6" 7" 15¹ ₂" 11³ ₄" 2" ⁷ ₈" RSH-827 thru 830 7" 8¹ ₂" 18" 13¹ ₂" 2¹ ₄" 1" RSH-831/832 7" 8¹ ₂" 18" 14" 2¹ ₄" 1" & SIZE in. lbs. lbs.in. COLOR RSH GRAY RSH PINK RSH BROWN RSH BLUE RSH RED RSH WHITE RSH GREEN RSH BLACK RSH YELLOW RSH PURPLE RSH ORANGE RSH GRAY RSH PINK RSH BROWN RSH BLUE RSH RED RSH WHITE RSH GREEN RSH BLACK RSH YELLOW RSH PURPLE RSH ORANGE 10

11 SERIES RSH 30A 1"/ 1¹ ₂" / 2" deflection TYPE & SIZE A B D E F G RSH-30A-6 thru 10 RSH-30A-11 thru 16 RSH-30A-92 thru 99 RSH-30A-6W/10W RSH-30A-13W/16W 2¹ ₄" 2³ ₄" 5¹ ₄" 2⁷ ₈" ¹⁵ ₁₆" ³ ₈" 3" 3¹ ₄" 7" 3" 1¹ ₂" ⁵ ₈" 4¹ ₂" 5" 10³ ₁₆" 4³ ₈" 2¹ ₈" ³ ₄" 4¹ ₂" 5" 10³ ₁₆" 4⁵ ₈" 2¹ ₈" 1" 4¹ ₂" 5" 10³ ₁₆" 4⁵ ₈" 2¹ ₈" 1" RSH-30A-20W/25W 4¹ ₂" 5³ ₈" 12³ ₈" 6" 2¹ ₈" 1" RSHM-30A-100 thru 106 4¹ ₂" 5³ ₈" 12³ ₈" 6¹ ₄" 2¹ ₈" 1" RSHM-30A-107 thru 109 4¹ ₂" 5³ ₈" 12³ ₈" 6¹ ₄" 2¹ ₈" 1" RSH " 5" " 4 3 4" 2 1 8" 3 4" RSH " 5 3 8" " 5 7 8" 2 1 8" 1" RSHD-30A-50 thru 52 4¹ ₂" 5³ ₈" 12³ ₈" 7" 2¹ ₈" 1" RSHD-30A-53 4¹ ₂" 5³ ₈" 12³ ₈" 7" 2¹ ₈" 1" RSHD-30A-55 4¹ ₂" 5³ ₈" 12"³ ₈ 7" 2¹ ₈" 1" Large bottom hole ensures that rod can swing 30 to prevent metal to metal contact & SIZE in. lbs. lbs./in. COLOR RSH-30A BLUE RSH-30A BLACK RSH-30A RED RSH-30A GREEN RSH-30A GRAY RSH-30A BLUE RSH-30A ORANGE RSH-30A BROWN RSH-30A BLACK RSH-30A YELLOW RSH-30A BROWN RSH-30A ORANGE RSH-30A GREEN RSH-30A RED RSH.30A BLACK RSH-30A WHITE RSH-30A GRAY RSH-30A BLUE RSH-30A-6W RED RSH-30A-10W GREEN RSH-30A-13W YELLOW RSH-30A-16W GRAY RSH-30A-20W BROWN RSH-30A.-25W ORANGE RSHM-30A BROWN RSHM-30A ORANGE RSHM-30A GREEN RSHM-30A RED RSHM-30A BLACK RSHM-30A WHITE RSHM-30A GRAY RSHM-30A BLUE RSHM-30A YELLOW RSHM-30A PINK RSH-30A BLUE RSH-30A ORANGE RSH-30A PURPLE RSH-30A YELLOW RSH-30A GRAY RSH-30A RED RSH-30A GREEN RSH-30A BLUE RSH-30A YELLOW RSH-30A BLACK RSH-30A PURPLE RSH-30A BROWN RSH-30A RED RSH-30A ORANGE RSHD-30A BLUE RSHD-30A BLACK RSHD-30A RED RSHD-30A GREEN RSHD-30A GRAY 11

12 SERIES RSHP 1" & 2" deflection 12 TYPE & SIZE A B D E F G H RSHSP-11 thru 18 RSHP-19 thru 32 RSHWP-200 thru 1000 RSHWP-1300 thru 1628 RSHDP-50 thru 530 RSHDP-531 thru 553 RSHWP thru " 3¹ ₄" 7" 3⁷ ₈" 3¹ ₈" 1¹ ₂" ⁵ ₈" 4" 4³ ₄" 12³ ₈" 6¹ ₄" 4⁵ ₈" 2¹ ₈" ³ ₄" 4" 4³ ₄" 12³ ₈" 6¹ ₄" 4⁵ ₈" 2¹ ₈" 1" 4" 4³ ₄" 12³ ₈" 6¹ ₄" 4⁵ ₈" 2¹ ₈" 1" 4" 4³ ₄" 15" 8¹ ₄" 7" 2¹ ₈" 1" 4" 4³ ₄" 15" 8¹ ₄" 7" 2¹ ₈" 1" 5" 11" 16" 9¹ ₂" 6¹ ₂" 4" 1" To prevent load transfer to the equipment flanges when the piping system is filled, VMC has designed pre-positioning (Series RSHP) and pre-compressed (Series RSHPR) hangers which should be installed at the first three hanger locations adjacent to the equipment. Series RSHP incorporates a load bearing plate within the hanger box which keeps suspended piping at a fixed elevation during installation and start-up. Once the system is filled, the load is transferred from the plate to the spring insuring minimal movement in the piping. This design insures that the weight of the piping is kept off isolated equipment in order to maintain alignment, protect flexible connectors, and keep equipment isolators from becoming overloaded. Series RSHP is capable of supporting loads up to 5000 Ibs and offers up to 2 inches of static deflection. INSTALLATION INSTRUCTION SERIES RSHP HANGERS 1. Hangers are inserted in the hanger rods, or series SHP may be fastened directly to the structure. For best results, hangers should be located near the ceiling. 2. Piping or equipment should be hung at its proper elevation by inserting threaded rod up through the spring and suspended from the plate supplied in the hanger box. This plate is designed to maintain suspended equipment and piping at a fixed elevation during installation regardless of load changes. 3. The adjustment nut is provided to transfer the load to the spring after the piping system has been filled with water or the equipment is totally installed and level. 4. Turn the adjusting nut clockwise one complete turn on each hanger until the load is transferred from the supporting plate to the spring. & SIZE in. lbs. lbs.in. COLOR RSHSP BLUE RSHSP ORANGE RSHSP BROWN RSHSP BLACK RSHSP YELLOW RSHSP RED RSHSP GREEN RSHSP PINK RSHSP BLACK RSHSP BLUE RSHSP YELLOW RSHSP BROWN RSHSP RED RSHSP PURPLE RSHSP ORANGE RSHSP GREEN RSHSP GRAY RSHSP WHITE RSHWP BLUE RSHWP BLACK RSHWP RED RSHWP GREEN RSHWP YELLOW RSHWP GRAY RSHWP GRAY/RED RSHWP GRAY/GREEN RSHWP GRAY RSHWP GRAY/RED RSHWP GRAY/GREEN RSHDP BLUE RSHDP BLACK RSHDP BLACK/BLUE RSHDP RED RSHDP RED/BLUE RSHDP RED/BLACK RSHDP GREEN RSHDP GREEN/BLUE RSHDP GREEN/BLACK RSHDP GREEN/RED RSHDP GRAY/BLACK RSHDP GRAY/RED RSHDP GRAY/GREEN

13 SERIES KDX 1" & 1¹ ₂" deflection TYPE & SIZE A B C KDXS-6 thru 10 3" 1¹¹ ₁₆" ³ ₈" KDXS-11 thru 18 3¹ ₄" 2³ ₁₆" ⁵ ₈" KDX-19 thru 32 4⁵ ₈" 2³ ₁₆" ³ ₄" KDXW-200 thru ⁵ ₈" 3⁵ ₈" 1" KDXM-100 thru 109 6¹ ₈" 3⁵ ₈" 1" & SIZE in. lbs. lbs.in. COLOR KDXS BLUE KDXS BLACK KDXS RED KDXS GREEN KDXS GRAY KDXS BLUE KDXS ORANGE KDXS BROWN KDXS BLACK KDXS YELLOW KDXS RED KDXS GREEN KDX PINK KDX BLACK KDX BLUE KDX YELLOW KDX BROWN KDX RED KDX PURPLE KDX ORANGE KOX GREEN KDX GRAY KDX WHITE KDXW BLUE KDXW BLACK KDXW RED KDXW GREEN KDXW YELLOW KDXW GRAY KDXW GRAY/RED KDXW GRAY/GREEN KDXM BROWN KDXM ORANGE KDXM GREEN KDXM RED KDXM BLACK KDXM WHITE KDXM GRAY KDXM BLUE KDXM YELLOW KDXM PINK 13

14 14

15 15

16 INSTALLATION INSTRUCTIONS FOR VMC SERIES RH/SH/RSH HANGERS 1. Piping and equipment should be hung at its proper elevation by using temporary fixtures that can be removed after vibration hangers are installed and adjusted. 2. Hangers may be fastened directly to the structure (be sure not to short circuit the neoprene element in RSH series when fastening to the ceiling) or inserted in the hanger rods. For best results hangers should be located at or near the ceiling. 3. Install hangers 4. Turn nut on lower rod assembly clockwise one complete turn on each hanger. Repeat this procedure until temporary hanging fixtures are loose and load of piping or equipment is suspended completely on the vibration hangers. 5. Remove temporary hanger fixtures and level piping or equipment by taking additional turns on the lower hanger rod nut clockwise to raise, counter clockwise to lower as required. Vibration Mountings & Controls Inc. s ongoing product development, marketing and distribution prowess has made us a world-wide leader in the design and fabrication of vibration isolation components and damping materials used in the heating, ventilating, air conditioning, petrochemical, chemical, manufacturing, utility, construction and transportation industries. Computer supported engineering and the sophisticated skills of the VMC craftsmen continue to insure correctly designed and accurately manufactured product reliability for the vibration isolation of heating, ventilating and air conditioning pumps, fans and compressors, heavy rotating machinery, diesel engines and railroad, off-highway and military vehicles YOUR VMC FIELD ENGINEER IS: PIPING AND DUCTWORK ISOLATION (Design specification) Vibration isolation hangers shall be positioned as close as possible to the structure without coming in contact with any object (including the structure). Hanger rods shall not contact any object which would short circuit the isolator. Parallel running pipes may be hung together on a trapeze which is isolated from the building. Do not mix vibration isolated and non-isolated pipes on the same trapeze. Attention must be paid to movements of piping caused be expansion and contraction. Isolation hangers shall be installed for all piping in equipment rooms or for 50 ft. from vibrating equipment, whichever is greater. To avoid reducing the effectiveness of equipment isolators, at least three of the first hangers from the equipment should provide the same deflection as the equipment isolators, with a maximum limitation of 2-inch deflection. The remaining hangers shall be spring or combination spring and rubber with a minimum of 0.75-inch deflection. To prevent load transfer to the equipment flanges when the piping system is filled, the first three hangers adjacent to the equipment shall be the positioning type. Floor supports for piping in equipment rooms and adjacent to isolated equipment shall use restrained vibration isolators. They should be selected according to the guidelines for hangers. Vertical riser supports for pipe 4" diameter and larger shall be isolated from the structure using VMC Series VCS pipe sleeves and Series MDPA anchors and guides. All ductwork over four square feet face area located in the mechanical equipment room(s) shall be isolated with type SH hangers with a minimum of 0.75 inch deflection. Emergency generator exhaust shall be isolated with SH hangers with a minimum of 0.75-inch deflection. Vibration Mountings & Controls, Inc. An Aeroflex, Inc. Company 113 Main St., Box 270, Bloomingdale, NJ Tel: 973/ TOLL FREE: LOW-VIBE FAX: 973/ Vibration Mountings & Controls, Inc. 5M 4/2000

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

KINETICS TM. 1" and 2" Deflection Isolation Hangers Model SRH. Polyester Powder Coated Bracket and Spring Coil Self-Centering Cap Patent No.

KINETICS TM. 1 and 2 Deflection Isolation Hangers Model SRH. Polyester Powder Coated Bracket and Spring Coil Self-Centering Cap Patent No. Polyester Powder Coated Bracket and Sprg Coil Self-Centerg Cap Patent No. 5,6,426 Application Ketics Model SRH hangers are used to isolate suspended sources of both noise and vibration. Suspended mechanical

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

TRANS-05, Torque Tube Removal, Rebuilding, and Installation TRANS-05, Torque Tube Removal, Rebuilding, and Installation Tools Metric Wrench Set Metric Socket Set Jack Stands (6 minimum) Floor Jack 8mm Cheesehead socket (also referred to as 12 point internal socket

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades. 1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National

More information

Vibration Isolation Products. Spring Isolators. Isolation Hangers. Thrust Restraints. Flexible Connectors. Isolation Bases. Rooftop Isolation Curbs

Vibration Isolation Products. Spring Isolators. Isolation Hangers. Thrust Restraints. Flexible Connectors. Isolation Bases. Rooftop Isolation Curbs Spring Isolators Isolation Hangers Thrust Restraints Flexible Connectors Isolation Bases Rooftop Isolation Curbs Neoprene Isolators Fiberglass Isolators Air Mounts Seismic and Wind Restraint Isolators,

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,

More information

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT. 1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National

More information

INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT

INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT VISCMA 412/August 2014 INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT August 2014 Developed originally by the Vibration Isolation and Seismic Control Manufacturers Association under a cooperative

More information

QR12 (1.22 ) Diameter Optical Encoder

QR12 (1.22 ) Diameter Optical Encoder Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Turbo Tube Slide INSTALLATION INSTRUCTIONS C A U T I O N Do not climb on the outside of the slide This slide is designed for home use only, not for Public Playgrounds PlayCore, Inc. 2004 Copyrighted Material.

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form 3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO

More information

Ceiling Mounted Folding Attic Ladders Installation Instructions

Ceiling Mounted Folding Attic Ladders Installation Instructions Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:

More information

Check for deteriorated, shifting or missing tie-down pads. Replace if needed.

Check for deteriorated, shifting or missing tie-down pads. Replace if needed. C C 0 5 C H A S S I S F R A M E Chassis Frame Overview The Blue Bird Vision s chassis frame consists of two main C-channel rails which run the entire length of the bus, and several different kinds of cross

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

SELF-STEERING AXLE TABLE OF CONTENTS

SELF-STEERING AXLE TABLE OF CONTENTS SELF-STEERING AXLE TABLE OF CONTENTS Section 1 - Introduction Section 2 - Pre-Installation Check List Section 3 - Ride Height Adjustments Section 4 - Suspension Mount Section 5 - Axle Mount Section 6 -

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

Little British Car Co.

Little British Car Co. Little British Car Co. 29311 Aranel, Farmington Hills, MI 48334-2815, USA Tel: 248 489 0022 or 800 637 9640 Fax: 248 489 9665 On the web at: www.lbcarco.com E-mail: [email protected] MGB Tube Rear Shock

More information

POLE MOUNT SYSTEM-3 INSTALLATION

POLE MOUNT SYSTEM-3 INSTALLATION 1 May 2014 POLE MOUNT SYSTEM-3 INSTALLATION The Pole Mount System-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker products to be mounted to pole structures. The only

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

Installation Instructions: Electrical System for Towing Hitch...3

Installation Instructions: Electrical System for Towing Hitch...3 Fehler! Textmarke nicht definiert....3 Installation Instructions:...3 317 056 391 104-002 - 22/07 Westfalia Skoda 317 056 300 153 Skoda Octavia II (1Z), 4x4, RS, RHD 3 2 1 1 2 3 4 5 6 7 2 317 056 391 104-002

More information

KINETICS QuakeLoc Connector

KINETICS QuakeLoc Connector MADE IN THE USA MADE IN THE USA MADE IN THE USA MADE IN THE USA QuakeLoc Seismic Cable Restraint Connector for piping, duct, electrical cable trays, and suspended equipment. MADE IN THE USA QuakeKit-P

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

I BEAM TRACK INSTALLATION

I BEAM TRACK INSTALLATION PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must

More information

Lightweight, Heavy Duty

Lightweight, Heavy Duty Lightweight, Heavy Duty Trench Covers System Reliability The light weight combined with the tremendous strength of Comcore Trench Covers translates into speed, productivity and increased system reliability.

More information

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

Mueller B-101 and A-3 Drilling and Tapping Machines

Mueller B-101 and A-3 Drilling and Tapping Machines TM TM Mueller and Drilling and Tapping Machines A guide to selecting Mueller Equipment Mueller TM TM and Drilling and Tapping Machines When it comes to line stopping and drilling and tapping technology

More information

POLE MOUNT SYSTEM EX-3 INSTALLATION

POLE MOUNT SYSTEM EX-3 INSTALLATION May 2014 POLE MOUNT SYSTEM EX-3 INSTALLATION The Pole Mount System EX-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker systems to be mounted to pole structures. The

More information

Flamco Stainless steel mountings

Flamco Stainless steel mountings S TA I N L E S S S T E E L M O U N T I N G S 9 Flamco Stainless steel mountings BRS-A BSF - SS RAIL R - SS GP - SS Edition 2007 / UK Stainless steel mountings Flamco offers the best attachment options

More information

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions Ceiling Fan Installation Instructions 1525..series OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Total fan wieght with light kit 1-1525-CUL-English INSTALLATION CH-545 Safety Tips WARNING: TO REDUCE

More information

Rating when used as a weight carrying hitch without spring bars:

Rating when used as a weight carrying hitch without spring bars: BOLT-TOGETHER WEIGHT DISTRIBUTING HITCH SYSTEM Rating when used as a weight distributing hitch with spring bars: Part Number 48051 4805 48053 48054 Max Tongue Weight 550 Ibs. 750 Ibs. 1000 Ibs. 1400 lbs.

More information

VCS. MASON INDUSTRIES, Inc. COMPLETE HVAC ENGINEERING SPECIFICATIONS VCS-100-13 BULLETIN

VCS. MASON INDUSTRIES, Inc. COMPLETE HVAC ENGINEERING SPECIFICATIONS VCS-100-13 BULLETIN First Printing 1965 Revised 1973, 1974, 1975, 1976, 1979, 1982, 4/2001, 9/2001, 11/2003, 8/2005. 11/06, 1/08, 9/10 & MARCH 2014 MASON INDUSTRIES, Inc. Manufacturers of Vibration Control Products 350 Rabro

More information

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1 Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Power Cable 4000950-5 1 Raven Harness Adapter Kit 4100525 1 Installation Instructions

More information

Vehicle Power Install Kit

Vehicle Power Install Kit Vehicle Power Install Kit Installation Instructions Intermec Technologies Corporation Worldwide Headquarters 6001 36th Ave.W. Everett, WA 98203 U.S.A. www.intermec.com The information contained herein

More information

CortezTM A Kichler Décor Ceiling Fan

CortezTM A Kichler Décor Ceiling Fan CortezTM A Kichler Décor Ceiling Fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday Instruction

More information

PTFE Slide Bearings 04/10 149

PTFE Slide Bearings 04/10 149 04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,

More information

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter. ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations

More information

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant

More information

SUSP-06, Torsion Bars - Removing, Replacing, and Indexing

SUSP-06, Torsion Bars - Removing, Replacing, and Indexing Introduction SUSP-06, Torsion Bars - Removing, Replacing, and Indexing Replacing the torsion bar on a 944 is not all that difficult. However, reindexing the torsion after completion is a pain and can be

More information

Installation Guide A0 www.haikufan.com 2013 Delta T Corporation

Installation Guide A0 www.haikufan.com 2013 Delta T Corporation Installation Guide A0 Installation Guide: April 2013 Rev. J Model Number: K3150-A0 S3150-A0 May be protected by one or more of the following patents: Australian Registered Design No. 325331, 328015; U.S.

More information

Section A. GENERAL INFORMATION

Section A. GENERAL INFORMATION Section A. GENERAL INFORMATION I. Description The information and instructions for attaching the sidecar to the right-hand side of the motorcycle are contained in this handbook and must be carefully observed.

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054 owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact

More information

Nozzle Loads, Piping Stresses, and the Effect of Piping on Equipment

Nozzle Loads, Piping Stresses, and the Effect of Piping on Equipment Nozzle Loads, Piping Stresses, and the Effect of Piping on Equipment By Patty Brown & Mark van Ginhoven November 13, 2009 1 CA 2009 Fluor Corporation. All Rights Reserved. Topics Covered Introduction Nozzle

More information

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation CONTENTS 1EA. SUBWOOFER ASSEMBLY P/N RUWRANGLER 1EA. 200 WATT AMP/BRACKET ASSEMBLY P/N RM11JKBTL - Bracket P/N RE08BTL200R - Amp 1EA. POWER HARNESS P/N RHWRANGLERPWR 1EA. OVERLAY HARNESS P/N RHWRANGLER

More information

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Power Cube Open Source Ecology Page 1. Power Cube. Version 4 Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete

More information

TECHNICAL MANUAL FOR THE STAND ALONE BELT DRIVE ENCODER SYSTEM

TECHNICAL MANUAL FOR THE STAND ALONE BELT DRIVE ENCODER SYSTEM INTERNATIONAL LIFT EQUIPMENT LTD London Office Leicester Office Units 1&2 Wanlip Road Highams Park Ind Estate Syston Larkshall Road Leicester London Leicestershire E4 9JD LE7 1PD Telephone 0208 5279669

More information

Owner s Manual Gantry Cranes

Owner s Manual Gantry Cranes Owner s Manual Gantry Cranes Fixed Height Gantry Crane MODEL NUMBER: SERIAL NUMBER: CAPACITY IN TONS: Telescoping Gantry Crane Bushman AvonTec 262-790-4200, 800338-7810, Fax 262-790-4200 www.bushmanavontec.com

More information

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION ENGLISH REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION INSTALLATION GUIDELINES For Freightliner Cascadia ISO 9001:2000 L 2653 Rev. 20090130 WARNING: Only trained technicians should perform

More information

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE 1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.

More information

FTC 2015-2016 DIY Mountain Build Guide

FTC 2015-2016 DIY Mountain Build Guide FTC 2015-2016 DIY Mountain Build Guide Assembly Instructions Check out the DIY2015-2016 Prints and BoM for individual part details. Release 1.0 9/10/15 Page 1 This guide and Bill of Materials are for constructing

More information

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the

More information

Flex-Line Basics. Generating a Bill of Materials

Flex-Line Basics. Generating a Bill of Materials Flex-Line Basics Generating a Bill of Materials BRUCK LIGHTING SYSTEMS, INC. 15774 Gateway Circle Tustin, CA 92780 P: 714.259.9959 F: 714.259.9969 Website: www.brucklighting.com Flex-Line Ceiling Suspension

More information

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS THE LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT

More information

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION SPECIFICATION EO-5023 REVISION 3 MARCH 2003 REQUIREMENTS FOR

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment

Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment Testing Capabilities Twin Twin City City Fan Fan Companies, Companies, Ltd. Ltd. Worldwide Designers & Manufacturers of Air Moving Equipment TestingCapabilities Twin City Fan Companies, Ltd. In today s

More information

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

DeZURIK 3-20 BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT Instruction D10386 August 2013 Instructions These instructions provide installation, operation and maintenance information for BAW Butterfly Valves.

More information

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide 2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620 Quick Installation Guide Table of Contents Verify The Contents Inside Package Box... 3 Physical Installation... 4 Further Configuration...12 Verify

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Quick Connect Boxes Inside Gloveboxes

Quick Connect Boxes Inside Gloveboxes ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear

More information

Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.

Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1 1.5 x 1. Features: Will not rust. Corrosion resistant. Non-sparking. Fire retardant. Non-conductive. Maintenance free. Molded-in color. Light weight. Easy to install. Impact resistant. Quality appearance. Fabcograte

More information

54 LinkTM. Instruction Manual. Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S.

54 LinkTM. Instruction Manual. Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S. 54 LinkTM Includes our new CoolTouch Control System TM Looks permanent, but goes wherever you go! U.S. Patent Pending A Kichler Décor ceiling fan HIGH EFFICIENCY DC MOTOR Kichler Lighting 7711 East Pleasant

More information

MONDOATHENS BASKETBALL SET (Reference PK110)

MONDOATHENS BASKETBALL SET (Reference PK110) MONDOATHENS BASKETBALL SET (Reference PK110) DESCRIPTION The MONDOATHENS backstop unit is mainly designed for multi-sports pavilions and installations where the highest-level basketball competitions are

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

SCION tc 2005-2008 COIL OVER SUSPENSION Preparation

SCION tc 2005-2008 COIL OVER SUSPENSION Preparation SCION tc 2005-2008 COIL OVER SUSPENSION Preparation Part Number: PTR11-21070 NOTE: Part number of this accessory may not be the same as the part number shown. Kit Contents: Item # Quantity Reqd. Description

More information

Lathe Milling Attachment

Lathe Milling Attachment Lathe Milling Attachment By L C. MASON BY CLEVERLY stacking cold-rolled flat stock together, T-slots and slide for this lathe milling attachment are made without costly machinery. In fact, only two tools,

More information

AMP Standard Terminals and Splices. RoHS. Ready

AMP Standard Terminals and Splices. RoHS. Ready AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control

More information

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED. CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation. CHAPTER 5 PARTS PARTS BY PICTORIAL This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation. NOTE: The following is a breakdown description of the

More information

PAM Connectors. PAM Bayonet Connectors

PAM Connectors. PAM Bayonet Connectors PAM Bayonet Tel : 33 (0)1 60 84 21 40 Fax : 33 (0)1 60 84 43 81 [email protected] www.bernier.tm.fr Overview Miniature audio connectors with bayonet locking system, equipped with 07 or 10 contacts, and

More information

92-00 Civic/ 94-01 Integra/ 93-97 Del Sol/ 92-95 CRX Rear Kit Part No. 75540

92-00 Civic/ 94-01 Integra/ 93-97 Del Sol/ 92-95 CRX Rear Kit Part No. 75540 92-00 Civic/ 94-01 Integra/ 93-97 Del Sol/ 92-95 CRX Rear Kit Part No. 75540 www.airliftperformance.com MN-514 (06409) NPR 4762 Please read these instructions completely before proceeding with installation

More information

Knürr Smaract. Knürr Smaract. CompactRack

Knürr Smaract. Knürr Smaract. CompactRack CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.

More information

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints Watts Spacemaker Sa f e t y Wa t e r He a t e r Installation Products Enclosures Stands Restraints Ta b l e o f Co n t e n t s / In t r o d u c t i o n / Seismic Zo n e s Table of Contents Seismic Zones

More information

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1 Designation: E 580/E 580M 09a Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1 This standard is issued

More information

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

Chapter 5 FLOOR LOADING AND WEIGHTS

Chapter 5 FLOOR LOADING AND WEIGHTS Chapter 5 FLOOR LOADING AND WEIGHTS Section 1.0 Floor Loading Section 2.0 Seismic Data The CT system has a total floor load of approximately 6660 lbs (3021 kg). About 5050 lbs (2291 kg), including patient

More information

SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE

SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: Illuminated Kick Plate APPLICATION: Rogue (2011) PART NUMBER: 999G6 GX010 KIT CONTENTS: Item A B C G H QTY 1 1 1 D 1 E 1 F 3 15 6 Description Kick Plate,

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

StructureScan Installation

StructureScan Installation StructureScan Installation Contents Your StructureScan box is packed with the LSS-1 black box, a Power cable, StructureScan transducer, mounting bracket, 15 foot (4.5m) ethernet cable and a hardware kit.

More information

How To Replace A Reverse Osmosis Water Tank

How To Replace A Reverse Osmosis Water Tank ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate

More information

ACOUSTIC ISOLATION DETAILS

ACOUSTIC ISOLATION DETAILS ACOUSTIC ISOLATION DETAILS Icelandic National Concert and Conference Center Reykjavík, Iceland January 5, 2007 Artec Report No. 7742 Artec Project No. 3760 Distribution: Stefán Hermannsson East Harbour

More information

Calvert USA, Inc. Attic Stairs

Calvert USA, Inc. Attic Stairs Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,

More information

INSTRUCTION. Industrial Sewing Machines. No. 010012. First published : June 1997 Second edition : March 2001

INSTRUCTION. Industrial Sewing Machines. No. 010012. First published : June 1997 Second edition : March 2001 INSTRUCTION Industrial Sewing Machines First published : June 1997 Second edition : March 2001 No. 010012 INTRODUCTION Thank you for your purchasing Kansai Special's DLR Series. Read and study this instruction

More information