1 CEDES Safety Light Curtain for Elevator Door Protection MiniMax-79 MiniMax-159 MiniMax's unique variable lens technology feature provides criss-cross beams until full door closure for highest possible safety! C US IMPORTANT NOTE FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE TO DO SO MAY CAUSE CUSTOMER COMPLAINTS AND SERIOUS CALL BACKS. KEEP INSTRUCTION MANUAL ON SITE. CEDES / Version 25 th May 2010, Part Nr Rel A
2 MiniMax-79/159 IMPORTANT NOTICE WHEN THE MINIMAX LIGHT CURTAIN IS USED AS A REPLACEMENT FOR MECHANICAL SAFETY EDGES, IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT ON COMPLETION, THE INSTALLATION COMPLIES WITH ALL THE RELEVANT STATE CODES, LOCAL CODES AND REGULATIONS THAT PERTAIN TO INFRARED AND PHOTOELECTRIC DOOR PROTECTION DEVICES! PARTICULAR ATTENTION SHOULD BE GIVEN TO CLAUSE REOPENING DEVICES FOR POWER-OPERATED CAR DOORS OR GATES OUTLINED IN ASME A / CSA B44-07 SAFETY CODE FOR ELEVATORS AND ESCALATORS. MINIMAX MUST BE INSTALLED ONLY BY AUTHORIZED AND FULLY TRAINED PERSONNEL. PLEASE TAKE NOTE THAT OBJECTS THINNER THAN THE SENSOR SPACING MAY NOT BE DETECTED. DO NOT USE THIS PRODUCT FOR THE PROTECTION OF DANGEROUS MACHINERY OR IN EXPLOSIVE ATMOSPHERES OR RADIOACTIVE ENVIRONMENTS! USE ONLY SPECIFIC AND APPROVED TYPES OF SAFETY DEVICES FOR SUCH APPLICATIONS, OTHERWISE SERIOUS INJURY OR DEATH OF PERSONNEL MAY OCCUR! Ex 2 CEDES/May 2010
3 MiniMax-79/159 Table of Contents 1. Introduction Features of MiniMax Installation Switch main power off and mark clearly that this elevator is out of service Mount the emitter and the receiver Guide the cables properly to prevent damage Connect the emitter and the receiver cables Power-up and test for proper function Troubleshooting Maintenance Disposal Technical Data Certificate of Compliance Dimensions Part Numbers Complete units Spare parts and accessories CEDES/May
4 MiniMax-79/ Introduction The infrared light curtain MiniMax consists of an emitter and a receiver edge, both of which have a built-in controller. These two active parts are electrically connected directly to the door drive unit of the elevator and mechanically mounted either to the car door wings and / or to the slam post. There are various types of optional mounting kits available from CEDES. These kits are optimized to a specific door drive or car type. The emitter and the receiver edge build up a grid of infrared beams, which cover the door entrance to a height of 1,800 mm (6 feet). The number of beams covering the entrance area is dependent on the model in use. The number after the product name MiniMax indicates the maximum number of active beams. The higher the number, the more beams are active and therefore smaller objects can be detected. However, product cost increases with the number of beams. The emitter and the receiver require a power supply of between 10 and 30 VDC. The output of the receiver is a push / pull (PNP / NPN) stage, which is compatible with loads connected to positive as well as to negative power. The output signal of the receiver can be inverted by connecting the white input selector wire either to positive or to negative power. No electrical connection between the emitter and the receiver is necessary because MiniMax uses an optical synchronization principle. To increase the lifetime of the electronic components, especially the infrared emitters, the control unit continuously controls LED light emission power according to the distance between the emitter and the receiver. When the doors are closed, the emitting power is almost zero. This function also prevents optical bypassing at the car door sill. This makes MiniMax the most reliable device on the market. If a power supply of 10 to 30 VDC is not available, a state-of-the art Power Supply (including Relay contact) available from CEDES may be used. This product is especially useful in modernization applications where the supply voltage is not standardized or known. A specific feature of MiniMax is the reduction of light emission power in the infrared LED's. This unique feature was invented and patented by CEDES in 1990 and increases LED lifetime almost to infinity. However, this feature works properly only if the sequence of closing and opening the door is correct. When the doors are closing, the light emission power of the LED's decreases. Once the doors are closed, MiniMax turns off the angled beams. Only straight beams are active until the doors reopen by more than approximately 50 cm. This functionality has to be considered when MiniMax is under test in a laboratory where the closing and opening cycle are not followed. 2. Features of MiniMax Criss-cross beams until full closure for best-in-class detection capability Designed lifetime of more than 20 years using - gold plated contacts - reduced power output during door close cycle - special cable that withstands more than 20 million door openings (when properly installed) Robust and extremely compact design Plug'n-play edges with integrated controller Suitable for both side and center opening doors Suitable for metal and glass doors Suitable for dynamic and static installation Blanking of up to two defective sensor elements (not adjacent) after 45 seconds (This function is not available for units purchased in the United States or Canada.) Mechanically compatible to cegard/max If permanent blocking of a sensor element occurs, MiniMax recognizes this condition as a defective or blocked element. After 45 seconds, this particular sensor element is blanked and is no longer active. This function allows operation of the device even with partial damage or blockage due to vandalism. Up to two non-adjacent sensor elements in the emitter or receiver edges can be blanked out. Note: This function is not available for units purchased in the United States or Canada. 4 CEDES/May 2010
5 3. Installation The Installation should be done in the following sequence: 3.1. Switch main power off and mark clearly that this elevator is out of service For your own safety, turn the power off before you start working on the elevator! Clearly mark that this elevator is out of service Mount the emitter and the receiver The emitter and the receiver edge can be mounted either to the door wings, to the door wing and the slam post, or to a frame that is attached to the car. MiniMax-79/159 The black plastic profile with the curved surface is the front of the edge. This side has to "look" at its companion piece, which is mounted on the opposite cab door or slam post. Please note that the receiver (the edge with the blue connector) can be sensitive to "foreign" light. No other source of external light, including the emitter of any other light barrier system, should be directed towards the receiver edge. Although MiniMax is very tolerant of bright sunlight, it is better to mount the receiver edge so that no sunlight shines directly into the curved front area of the receiver lens. It is similar to human eyesight: while you may have visibility even if looking directly into the sun, it is harder to see clearly. Therefore, it is always better to have the sun at your back! Please note that objects smaller than the sensor spacing may not be detected! In the United States and Canada, MiniMax-79 shall be used only if the emitter and receiver edge are each set back from the leading edge of the door and/or slam post by at least one sixth of the full door opening. Please observe the following mounting guidelines: Emitter (white connector) Receiver (blue connector) Never scratch the curved front surface because this is the lens that forms the light path! At the installation site, leave the edges in the protective cardboard box / protective hose for as long as possible! The curved surface of the emitter and the receiver should point to each other face-toface! Align the optical axis of the emitter and the receiver as close as possible in order to achieve best performance (± 5 )! The recommended distance between the door sill and the bottom of the sensors is 6 mm (¼"). A greater distance reduces safety due to an unprotected area right above the sill! Do not bend or twist the edges! 1 Oil may damage the cable. Contamination must therefore be avoided at all times! 1 Depending of the environment temperature, the MiniMax edges may appear bowed. This is a natural phenomenon due to differing expansion coefficients of the plastic and aluminum components of the edges. Do not try to bend or twist the edges straight. CEDES/May
6 MiniMax-79/159 E R R E E R > 75'000 lux Other light sources Other light sources E R Avoid direct sunlight that could interfere with the receiver edge! Avoid external light from other infrared light sources like photo eyes or light barriers! 1/6 A In the United States and Canada, the MiniMax-79 can be used only if the emitter and the receiver edge are set back from the leading edge of the door and / or from the slam post by at least one sixth of the full door opening. 1/6 A A Cable tie wrap Slam post or door panel Screw the green / yellow wire to the grounded door panel to avoid electromagnetic noise pickup. Hence, the door panels shall be grounded. Fix the connector with a cable tie wrap to the door panel or mounting profile. yellow / green wire Figure A Top fixing part Aluminum cover The total length of the edges is 2,100 mm (7 feet). In case this is too long, the edges can be cut with a common metal saw. To do so, please comply with the following procedure in order to avoid damaging the device: 1. Cut the profile (Figure A) + Remove the top fixing part and the aluminum cover Bend the cable away from the area being cut Cut the plastic profile and the aluminum cover with a metal saw Figure B 2. Reassemble the profile (Figure B) Bend the cable upward (toward the lenses) Attach the top fixing part from the back and assure to mount it in the right direction Snap on the aluminum cover 6 CEDES/May 2010
7 3.3. Guide the cables properly to prevent damage Guide the cables properly using appropriate mounting material, e.g. cable protection tubes, neoprene cable ties and cable guide wires (depending on the type of mounting kit used). If the cables are not properly fixed and guided, their lifetime could be reduced drastically. They can also be damaged due to possible swing and snag in the hoistway! Always follow the cable guide instructions carefully, which can be found in this installation and operation manual. MiniMax-79/ Connect the emitter and the receiver cables Make sure that the power supply voltage available for MiniMax is between 10 and 30 Volts DC. The power supply has to provide at least 100 ma for proper operation. MiniMax meets all standards for resistance to electromagnetic interference (EMI). However, it is prudent to guard against interference. Therefore, do not guide MiniMax connection cables close to cables carrying high voltage and/or high current. The MiniMax cables should also be mounted as far away as possible from the door drive motor or motor inverter (VVVF-drives) to avoid EMI problems. Emitter edge Receiver edge Emitter brown: VDC blue: GND (0V) Receiver brown: VDC blue: GND (0V) black: Output white: Output Selector* (see below) Emitter Receiver Fuse 0.5 A slow blow VDC GND Power should be provided on site using overcurrent protection. Use a fuse with a 500 ma maximum rating that has a "slowblow" tripping characteristic. *Output voltage: Output Selector (white wire) connected to VDC (brown wire) GND V *Output voltage: Output Selector (white wire) connected to GND (blue wire) V GND 3.5. Power-up and test for proper function Turn on power after MiniMax has been correctly installed. The green LED's in the white emitter and the blue receiver plug should turn on to indicate that there is supply voltage available. The amber LED in the blue receiver plug is on, when one or more beams are interrupted. With no object and aligned edges, the amber LED is off. CEDES/May
8 MiniMax-79/ Troubleshooting If MiniMax does not operate as expected, observe the following troubleshooting guide step by step: 1. Check supply voltage both on emitter and receiver. Are the green LED's in the emitter and receiver plug on? Is the supply voltage between 10 and 30 Volts DC? The ripple on the DC voltage should not exceed more than 10 % of the mean voltage. 2. If the output of the receiver (black wire) is high when the protected area is not obstructed, and in this case it should be low, connect the white wire of the receiver cable to ground (blue wire, refer to page 7: Output voltage) 3. If the output of the receiver (black wire) is low when the protected area is not obstructed, and in this case it should be high, connect the white wire of the receiver cable to positive power (brown wire, refer to page 7: Output voltage). 4. If the output signal of the receiver is not stable during the closing of the door, make sure that: a. there is not excessive EMI-noise generated by the door drive or the door inverter or any other means that is disturbing the door edge. In such a case, move the cable of the receiver so that the distance to the noise source is as wide as possible. In addition, filter the noise of the source by using the optional Power Supply (including Relay contact) available from CEDES. b. there are no obstacles between the emitter and the receiver. Make sure that the door lock or any other obstacle does not enter the light path. c. the edges are properly installed so that they cannot swing or vibrate and therefore lose line of sight between themselves. d. the curved front surfaces of the edges are clean and not full of dust or dirt. Although MiniMax is very tolerant to this condition, its performance is much better when it is clean. 5. If the doors are closing even with an obstacle 1, there could be several reasons: a. Output selector (white wire) not properly set (see steps 2 and 3 above) b. Output not correctly wired to door operator c. Faulty/defective system wiring or defective receiver edge 2 5. Maintenance The MiniMax is designed for little or no maintenance requirements. However, we strongly recommend that a functional check occurs with every elevator maintenance check, or every 6 months. This periodic functional test should consist of the following: - Test the reopening function over the whole door area. The door should reopen if an object is placed anywhere between the sill and up to 6 feet above the sill. - Clean the front surface with a soft towel from dust or dirt. Especially when the door edges are installed before the construction of the building is finished (perhaps weekly during construction). To clean the surface with a towel, it must be either dry or slightly moist, but not wet. - Confirm edges are fastened securely to the door wings and slam post. - Confirm cables are routed properly as described in the appropriate mounting kit installation manuals. Important notices: Never use any solvents, cleaners or mechanically abrasive towels to clean the edge. The plastic lens can be damaged! Although the edges are water and weather resistant, never use lots of water to clean the edges! Never use high pressure water to clean the edges! Do not scratch the surface when cleaning the edges! Disregard of the mentioned precautions may lead to a loss of safety! 6. Disposal The light curtain should only be replaced if a similar door protection device is installed. Disposal should be done using the most up-to-date recycling technology according to local rules and laws. There are no harmful materials used in the design and manufacture of this light curtain. Traces of such dangerous materials could be used in the electronic components but not in quantities that are harmful to health. 1 Due to the nature of door system designs, (which as complete systems are not fail safe), doors can close even with an obstacle present in extremely rare conditions. Therefore, there must be, by code, other safety means to prevent passengers from being hurt by the elevator doors. These dangerous situations should and can be detected by the elevator control, which should, in such a case, take the elevator out of service. 2 This device (as well as all other door protection systems on the market) cannot by its nature provide absolute safety for elevator passengers passing through the doorway. It must not be used as the final fail safe device of the door mechanism. This ultimate safety function has to be provided by a fail safe force and kinetic energy limiter. 8 CEDES/May 2010
9 MiniMax-79/ Technical Data Supply voltage VDC Supply current typ. 60 ma (protected using a "slow-blow" 0.5 A fuse) Output type Semiconductor Output switching current max. 120 ma Output polarity Push and pull (PNP and NPN) Output logic NO and NC selectable Response time ms Operating range m ( feet) Protection height 1,800 mm (6 feet) First beam above lower end of edge 20 mm (0.78 ) Weight 0.3 kg Sunlight > 75,000 Lux Protection class IP 65 / Nema 4 Temperature range C ( F) Cable length 5 m, detachable, color coded Cable lifetime 20 million door movements (if correctly installed) Diagnostics LED's built into the connector 7.1. Certificate of Compliance EU Standards EMV 89 / 336 / EC, changed 92 / 31 / EC CSA Certificate no. No Applicable Standards and Requirements Quality EN , -2 EMI Emission EN , -2 EMI Immunity EN12015 EMI Emission for elevators and escalators EN12016 EMI Immunity for elevators and escalators CSA C22.2 No. 0 - M91 CSA C22.2 No CSA C22.2 No M91 CSA - B / ASME - A ed. UL 508, 16th ed. UL 50, 11th ed. All CEDES products are developed and manufactured following generally accepted rules in industry and in compliance to a total quality management system certified to ISO 9001: CEDES/May
10 MiniMax-79/ Dimensions Emitter (white) Receiver (blue) 2110 (83.07" 2) ) 2104 (82.83" 1) ) ( ) * * Variable edge length 3) Dimension of the top fixing part: 1717 (67.60 ) 10.4 (0.41) 1282 (50.47 ) 10.1 (0.40) 14 (0.55) Dimension and cross section of the sensor strip: 847 (33.35 ) 427 (16.81 ) Protection height = 1800 (70.87 ) Max. edge length = 2114 (83.22 ) Min. edge length = 1860 (73.22 ) 16 (0.63) 7.7 (0.30) Ø 4.6 (0.18) 12 (0.47) 7 (0.28 ) Ø 4.8 (0.19) 1) = Location for side mounting 2) = Location for front mounting 3) = Edge length can be adjusted individually between min. and max. edge length *) = Top fixing part ) = Mounting holes All dimensions in mm (Inches) 10 CEDES/May 2010
11 MiniMax-79/ Part Numbers 9.1. Complete units CEDES Part No. Description MiniMax-159 for 24 VDC power supply, 7' application WITHOUT vision shield or mounting profile MiniMax-159 for 24 VDC power supply, 7' application with vision shield and mounting profile MiniMax-79 for 24 VDC power supply, 7' application WITHOUT vision shield or mounting profile MiniMax-79 for 24 VDC power supply, 7' application with vision shield and mounting profile 9.2. Spare parts and accessories CEDES Part No. Description Power line converter with relay output for voltages ranging from 85 to 265 VAC Universal power supply with relay output for voltages ranging from 17 to 265 VAC or VDC MiniMax-159, emitter MiniMax-159, receiver MiniMax-79, emitter MiniMax-79, receiver Vision shield 7' Mounting profile 7' MiniMax 16' transmitter cable (for MiniMax-159 and MiniMax-79) MiniMax 16' receiver cable (for MiniMax-159 and MiniMax-79) MiniMax 10' extension cable for transmitter and receiver (for MiniMax-159 and MiniMax-79) Aluminium cover (for MiniMax-159 and MiniMax-79) Hardware bag (for MiniMax without vision shield or mounting profile) Hardware bag (for MiniMax with vision shield and mounting profile) CEDES/May
12 MiniMax-79/159 CEDES AG is certified according to ISO 9001: CEDES AG reserves the right to modify or change technical data without prior notice.
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
sensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
MULTI-BEAM LS10 Light Screen System
For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small
Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option
REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
Operating Instructions. UL325 Compliant Non-monitored
IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
TOYOTA Tundra 2007 - BACK-UP CAMERA SYSTEM Preparation
Preparation Part Number(s): PT233-34070, PT923-35070-11, PT923-35070-43 NOTE: Part number of this accessory may not be the same as part number shown. Back Up Monitor Kit Contents PT923-35070-11 / PT923-35070-43
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451. www.lorextechnology.com
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451 www.lorextechnology.com Contents 1x Camera and mounting stand 1x Power adapter 1x Mounting kit 1x Allen key 1x Screw cap 1x 60 ft. (18m)
Smart Sensing Solutions Since 1954
Smart Sensing Solutions Since 1954 X-tremely High Speed Photoelectric Registration Sensor 800-237-0946 ttco.com 813-886-4000 Photoelectric Registration Sensor The SMARTEYE X-MARK TM is the fastest, most
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval
series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat
W150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW
WARNING CARTON INVENTORY CAUTION with: Charger, Cable 15', Fuses (2), Battery Strap and Strain Relief (2) Model SOLBBOX 12V Battery Not Included AVERTISSEMENT ATTENTION DC Power Adapter 12Vdc to 32Vdc
Video Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Tina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal
O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat
FREEZE Freezer equipment Canopy lighting High efficiency QCS Quick-Connection-System Dimmable Various lengths Daylight Neutral White Fresh Meat Packed Meat 1 A FREEZE Canopy PRODUCT DESCRIPTION 19.8 mm
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Networkfleet 3500 Product Line Installation Guide
Networkfleet 3500 Product Line Installation Guide Light/Medium Duty (L3500) Heavy Duty (H3500) Universal (U3500) www.networkcar.com/fleet Customer Care: (866) 227-7323 [email protected] Table
New XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
intelligent solutions
Lichtschranken W 8- Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 8-: Integrated stateof-the-art technology
Universal Voltage Terminal Photoelectric E3JM
Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure The Microscope: A Tool of the Scientist You may refer to pages 66-67, 72-73 in your textbook for a general discussion of microscopes.
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
INDICATOR LAMPS & LED REPLACEMENT LAMPS
INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC
Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.
www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing
Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS CONTENTS Parts List... 2 Parts Diagram... 2 Helpful Hints... 3 Installation... 4 Operation and Troubleshooting Guide... 6 Warranty Information... 8 Form #3132,
COOL Shelf Quick Connect
Refrigeration equipment Shelf lighting High efficiency COOL QCS Quick-Connection-System Dimmable Various lengths Neutral White Warm White Pasta & Cheese Fresh Meat Packed Meat 1 A COOL Shelf Quick Connect
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!
Installation Instructions Avalanche XUV Cap IMPORTANT! Read all instructions carefully before commencing any work. Always wear safety equipment. Some installation steps will require two or more installers.
Guide to Safety Edge Systems
Guide to Safety Edge Systems Tel: 0845 054 5070 [email protected] Guide to Safety Edges All new automatic gate & door systems installed in the UK should comply to BS-EN13241-1 & EN-138491-1 harmonised
Capacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
13 Watt PORTABLE SOLAR POWER KIT
3 Watt PORTABLE SOLAR POWER KIT User s Manual Thank you for purchasing a Sunforce Portable Solar Power Kit. Please read these instructions carefully and thoroughly before using the product. Your new Portable
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables
OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3
2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro
KNX R. Rain Sensor. Installation and Adjustment
EN KNX R Rain Sensor Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes... 4 2.2. Location... 4
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
LED...A70..4-..Q Series Sealed High-Intensity
LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
W 36: Mastering complex tasks reliably
Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures
Ingenico. User Guide 5100M. Secure transaction and payment solutions
User Guide Ingenico 5100M Secure transaction and payment solutions Ingenico 5100 M Contents 1 Presentation... 5 1.1 Overview of Ingenico 5100... 6 1.2 Keyboard details and functionality... 7 2 Use...