General basis for ballistic material, construction and product tests - Requirements, test levels and test procedures -
|
|
|
- Katherine Henderson
- 9 years ago
- Views:
Transcription
1 General basis for ballistic material, construction and product testing Englische Übersetzung, es gilt immer die deutsche Originalfassung! English translation, howewer the original German version always prevails! Editor: resistant materials and () Page 1 of 29
2 First edition of : List of Amendments No. Amendments Date Modifications were made and numbered as follows (Upgrading to 14 levels, thus modifications for the levels 12 to 14 ) Front page (Modification of terms, thus modification for 3.1.2, 4.1, and 7.3), Introduction, 6.4.3, 6.5.1, 6.5.2, 6.6, attachment 2 (calculation method) and attachment Introduction, 4.1 (testing level 9 and completion of the legend for table 1), 6.2 (5. enumeration), 6.6 (energy value in the example) and attachment 3 (dropped) page 2 of 29
3 Foreword This guideline was developed by the (). Reference source of - : Office Deutsche Hochschule der Polizei Polizeitechnisches Institut Postfach Muenster Germany Tel.: +49 (0) Fax: +49 (0) [email protected] Internet: oder page 3 of 29
4 Objectives of was founded in 1999 by the executive members with the aim to promote experience exchange and mutual assistance with possible questions regarding bullet. The co-operation is supported by a common statement regarding engineering standards, guidelines and other regulations. The publishing of own test guidelines ensures reproducible results on the one hand and more market transparency for customers and users on the other hand. This is due to the objective evaluation other suppliers products and test reproducibility. The members of are independent and committed to neutrality. The test centres, which are members of, operate exclusively according to appropriate quality specifications EN ISO/IEC (general requirements on the expertise of testing laboratories) and EN (general requirements on institutions which do product certification systems). The contact details of all -members are listed online: page 4 of 29
5 Table of contents Page 1 Fields of application Normative Reference Terms General terms Bullet/ballistic resistance Test level Classification Model name/identifier or model number Terms for test specimen Impact side Sample Test specimen Terms for the test procedure Impact velocity Impact point Impact angle Ballistic limit V Penetration Penetration/fragment indicator Backing material Indentation diameter Indentation depth Shot distance Hit distance Hit distance to the edge Terms for bullets Solid bullets L/RN = Lead / Round Nose FMs/CB = Full Ms / Coned Bullet Soft core bullets FMJ/RN/SC = Full Metal Jacket / Round Nose / Soft Core FMJ/PB/SC = Full Metal Jacket / Pointed Bullet / Soft Core FMJ/CB/SC = Full Metal Jacket / Coned Bullet / Soft Core FMJ/FN/SC = Full Metal Jacket / Flat Nose / Soft Core FMJ/FeC = Full Metal Jacket / Fe-Core (non hardened) FMJ/SCP = Full Metal Jacket / Soft Core Penetrator Full Metal Jacket/Hard core FMJ/HC = Full Metal Jacket / Hard Core (steel core) FMJ/PB/HCI = Full Metal Jacket / Pointed Bullet / Hard Core / Incendiary FMJ/WC = Full Metal Jacket with tungsten carbide core...12 page 5 of 29
6 4 Test conditions Tests with standardized types of ammunition Measuring and test equipment Test set-up Weapon system Accuracy of the measuring equipment Fragment indicator Penetration indicator Backing material Test procedures General facts Test relevant parameters Repetition of the test Calculation of the ballistic limit V Test procedures STANAG 2920 Method Method -KNB Statistical risk analysis Determination of critical velocity for a given penetration probability Determination of the penetration probability at given impact velocity Reference materials (Residual energy measurement) Evaluation and documentation of the test Evaluation of the test Test report Test certificate/test confirmation Validity test certificate/test confirmation Traceability of the results Details on material and material processing Attachment 1: Test set-up Attachment 2: Form for the determination of V 50 and standard deviation s page 6 of 29
7 1 Fields of application This guideline describes the basis for ballistic tests and/or conformity assessment 1 of materials, and products, which offer protection against attacks by firearms. The technical bases includes: Definitions Test conditions Test- and measuring equipment Test procedure(s) Evaluation and documentation of the test This guideline is completed with product-specific guidelines of in which the deviant test conditions, test- and measuring equipment and test methods can be mentioned. 2 Normative Reference The following standardised documents contain modalities that have to be considered as part of this test guideline as they are referred to. Standards, references and legal regulations must always be applied according to their latest versions. EN 10204, metallic products types of test certificates EN 1063, glass in construction engineering special safety glazing test methods and classification for the resistance against proof firing STANAG 2920, ballistic test method for personal armour materials and combat clothing STANAG 4569, protection levels for occupants of logistic and light armoured vehicles guidelines TDCC, dimension sheet of the permanent international commission for the test of small arms (C.I.P.) 1 To simplify this text the term test will be used in the following. page 7 of 29
8 3 Terms For the use of this general guideline the following terms are valid: 3.1 General terms Bullet/ballistic resistance The resistance a material or a construction offers against the penetration of a projectile under defined conditions. A material or a construction is bullet-resistant if it offers a defined resistance against attacks with specific types of arms and munitions Test level Name for the classification of a resistance against a defined attack potential Classification Allocation to a particular class according to the tested bullet-resistant behaviour under defined conditions Model name/identifier or model number A unique name or code which is only assigned once and which identifies the model, the type and the materials used of a tested product. 3.2 Terms for test specimen Impact side The side of the test specimen which is facing the impact and which has to be marked by the manufacturer/client Sample One or more test specimen, which are necessary for the test. page 8 of 29
9 3.2.3 Test specimen An item provided for testing which is implemented according to the test guidelines. Note: model, type and materials used of the samples must coincide with the information provided by the manufacturers or the clients and must be representative for the product. The test specimen should be accompanied by inspection certificates (e.g. batch number) or a precise description of its structure (in particular the material composition) and the manufacturing process. 3.3 Terms for the test procedure Impact velocity The velocity of the projectile in m/s at a distance of max. 2.5 m in front of the impact point Impact point A fixed point on the test specimen which should be striked by the projectile. It will be marked in the appropriate place prior to firing Impact angle The angle between the direction of the projectile and the line which is perpendicular (90 equals 0 NATO) to the tangent plane to the impact point on the impact side of the test specimen Ballistic limit V 50 The velocity of the projectile corresponding to a probability of 0.5 (50%) that the defined projectile penetrates the test specimen Penetration Is stated if 1. a projectile or projectile fragment completely penetrates the test specimen 2. the rear surface of the test specimen is penetrated by the stuck projectile or the stuck projectile fragment 3. the test specimen provides an opening on its backside with a light passage without evidence of no.1 and/or no.2 4. a specified penetration indicator is penetrated. page 9 of 29
10 3.3.6 Penetration/fragment indicator Is positioned behind the test specimen for the test duration depending on the product specific requirements. It shows the penetration of the specimen by the projectile and/or projectile fragments respectively splinter of the test specimen Backing material Depending on the product specific requirements it is arranged behind a test specimen for the test duration. The material shows the deformation of the backside of the test specimen due to the projectile Indentation diameter The greatest diameter of the indentation in the backing material after the projectile striked the test specimen Indentation depth The greatest depth of the indentation in the backing material after the projectile striked the test specimen. The depth is measured in relation to the original surface of the backing material which is shown in the area of the surrounding non-affected materials Shot distance The distance between the muzzle of a weapon and the impact point of the projectile on the test specimen Hit distance The distance between the centres of two hits on the test specimen Hit distance to the edge The distance between the impact point and the nearest line which marks the edge of the protection area. page 10 of 29
11 3.4 Terms for bullets Solid bullets Solid bullets consist of a homogeneous material such as lead, brass or tombac without a jacket L/RN = Lead / Round Nose FMs/CB = Full Ms / Coned Bullet Soft core bullets Soft core bullets consist of a deformable core such as a lead or Fe-core and a jacket FMJ/RN/SC = Full Metal Jacket / Round Nose / Soft Core FMJ/PB/SC = Full Metal Jacket / Pointed Bullet / Soft Core FMJ/CB/SC = Full Metal Jacket / Coned Bullet / Soft Core FMJ/FN/SC = Full Metal Jacket / Flat Nose / Soft Core FMJ/FeC = Full Metal Jacket / Fe-Core (non hardened) FMJ/SCP = Full Metal Jacket / Soft Core Penetrator page 11 of 29
12 3.4.3 Full Metal Jacket/Hard core Full Metal Jacket/Hard Core consists of a non deformable core or core component and a jacket. Note: These bullets are also known as Armour Piercing (AP) FMJ/HC = Full Metal Jacket / Hard Core (steel core) FMJ/PB/HCI = Full Metal Jacket / Pointed Bullet / Hard Core / Incendiary FMJ/WC = Full Metal Jacket with tungsten carbide core page 12 of 29
13 4 Test conditions 4.1 Tests with standardized types of ammunition Table 1: Classification of the test levels Test level Type of weapon Calibre Type Ammunition and projectile Mass [g] Manufacturer Type Test conditions shot distance [m] Bullet velocity [m/s] 1 K/L 22 Long Rifle L/RN 2,6 ± 0,1 Winchester ± 10 2 K 9 mm Luger 5) FMJ/RN/SC, tinned 8,0 ± 0,1 DAG, DM ± 10 3 K 9 mm Luger 5) FMJ/RN/SC, tinned 8,0 ± 0,1 DAG, DM ± ) K 357 Magnum FMJ/CB/SC 10,2 ± 0,1 Geco ± Rem. Mag. FMJ *) /FN/SC 15,6 ± 0,1 Speer ± 10 5 K 357 Magnum FMs/CB 7,1 ± 0,1 DAG special ± 10 6 L 7,62 x 39 FMJ/PB/FeC 8,0 ± 0,1 core 3,6 PS cold hardened ± ) L 223 Rem. 2) FMJ/PB/SCP 4,0 ± 0,1 MEN, SS ± Win. FMJ/PB/SC 9,55 ± 0,1 MEN, DM ± 10 8 L 7,62 x 39 FMJ/PB/HCI 7,7 ± 0,1 core 4,1 hardness 65 HRC BZ ± 10 9 L 308 Win. 3) FMJ/PB/HC 9,70 ± 0,2 core 4,0 ± 0,1 hardness 62 ± 2 HRC MEN/CBC, FNB, P ± L 7,62 x 54 R FMJ/PB/HCI 11 L 308 Win. 3) FMJ/PB/WC 12 L 308 Win. 3) FMJ/PB/WC 10,4 ± 0,1 core 5,3 hardness 63 HRC 8,4 ± 0,1 core 5,9 12,7 ± 0,1 core 5,58 hardness 1330 HV 10 B ± 10 Nammo, AP ± 10 SWISS P AP ± L 50 Browning FMJ/PB/HC 43,0 ± 0,5 core 35,0 hardness 55 ± 2 HRC SWISS P penetrator 6) 930 ± L 14,5 x 114 4) FMJ/PB/HCI 63,4 ± 0,5 B32 6) 911 ± 20 The rates of twist can be gathered from the dimension sheets (TDCC) of the C.I.P. page 13 of 29
14 Legend for the abbreviations used in table 1 FMJ FMJ *) CB RN PB FN L SC FeC SCP HC WC FMs I full metal jacket (steel) full metal jacket (copper) coned bullet round nose pointed bullet flat nose full lead lead-soft core mild-steel core lead-soft core steel penetrator hard core wolfram-carbide full brass Incendiary C.I.P. Permanent international commission for the testing of small arms TDCC Dimension sheets of the C.I.P. DAG RUAG Ammotec, Germany Geco RUAG Ammotec, Germany MEN Metallwerk Elisenhuette Nassau, Germany Nammo Nammo AS, Norway FNB FN Herstal, Belgium Speer Federal Cartridge Company, USA 1) 2) 3) 4) 5) 6) K L In theses steps both calibres are to use. twist rates 178 mm ± 5% twist rates 254 mm ± 5% twist rates arbitrary test barrel with a transition of 7,5 mm arbitrary shot distance. Appropriate hits have to be ensured in terms of velocity, oscillation and impact point handgun rifle The test steps 1 to 14 mentioned in table 1 are listed in increasing order according to their ballistic resistance. Test step 1 offers the lowest, step 14 the highest resistance against penetration. If a test specimen meets a particular level of resistance all underlying levels are also met. For and vehicles to be tested with a hard core or mild-steel core ammunition, splits, joints and overlaps will be additionally tested with soft core ammuniton. Step 6 and 8 are to be additionally tested with projectile FMJ/PB/SC calibre 7,62 x 39. Step 9 is to be additionally tested with the projectile in test step 7 calibre 308 Win. Step 10 is to be additionally tested with projectile type D (FMJ/PB/SC), 11,8 ± 0,1 g, v 0 : 810 ± 10 m/s calibre 7,62 x 54R. page 14 of 29
15 5 Measuring and test equipment 5.1 Test set-up The test set-up is shown in attachment 1. The shot distances are to be taken from table 1 paragraph 4.1. Additional and different requirements are described in the product specific test guidelines and/or standards. 5.2 Weapon system It is necessary to ensure that the parameters defined in table 1 paragraph 4.1 are to be met with the used weapon and ammunition. The compliance to the defined demands (e.g. impact point, bullet velocities) can require the use of particular tools and barrels as well as specially loaded ammunition. 5.3 Accuracy of the measuring equipment The determination of relevant measured quantities must comply to the following accuracies: Velocity - measuring system: 1 % Thermometer: ± 0.5 C Hygrometer: ± 1% relative humidity Length measuring equipment: 1% of the measured value. Protractor: ± 0.5 Scale: 1 of the measured value. 5.4 Fragment indicator If no rules are laid down in the product specific guidelines, an aluminium foil with a thickness of 0.02 mm and an area-weight of 54 g/m² according to no of EN 1063 has to be used as the fragment indicator. It has to be fixed 500 mm ± 10 mm behind the test specimen so that an area of minimum 440 x 440 mm remains free. 5.5 Penetration indicator If there no rules are laid down in the product specific guidelines, an aluminium sheet with a thickness of 0.5 mm (AlCuMg1, F 40) has to be used as the penetration indicator. It has to be fixed in a distance of 150 mm ± 5 mm behind the test specimen. page 15 of 29
16 If the fragment indicator has to be used in connection with the penetration indicator, the penetration indicator has to be set at a distance of 150 mm ± 5 mm behind the fragment indicator. 5.6 Backing material The backing material - if existent - is described in the respective product specific guidelines. page 16 of 29
17 6 Test procedures 6.1 General facts If the test procedures and parameters are not defined here refer to the product specific test guidelines. 6.2 Test relevant parameters Impact velocity: according to table 1, no 4.1 The ballistic velocity 2.5 m in front of the point of impact corresponds to the velocity of impact. Measuring systems which are capable of determining the factual velocity of impact are permitted. Ambient temperature: +20 ± 3 C Relative humidity: 65 ± 10 % Test specimen temperature: +20 ± 3 C Tolerance of location of point of impact and hit distances: ± 10 mm Shot distance: m alternatively m Angle of impact: 90 (0 NATO) and, if indicated, other angles defined in the product specific guidelines Configuration and size of specimen as well as construction and manufacturing methods. Material specifications have to be submitted by the applicant and, if required in the product specific guidelines, also demonstrated; e.g. with steels corresponding to the melt analysis according EN B as well as the corresponding identification 6.3 Repetition of the test If the results don t lead to an explicit assessment, the test may be repeated at an analogue point. This position mustn t be influenced by the previous hit. If in individual cases the bullet speed is outside the range, the shot shall be repeated only in the following cases: if at a speed below the lower speed limit no penetration occurred if at a speed above the upper limit penetration occurred page 17 of 29
18 6.4 Calculation of the ballistic limit V Test procedures The bullet velocity has to be determined as impact velocity according to paragraph The hits on the test specimen have to be chosen in a way that there are no prior damages of previous shots around the point of impact, which could influence the result. If the damage of the test specimen is too severe because of too many hits, the test has to be continued using a further test specimen. The tests have to be carried out with an angle of impact of 90 ± 2 (0 ± 2 NATO) as well as with the test arrangement according to attachment 1. If plasticine is used as backing material, it has to be planed after every shot and drawn off with a blade, the clamped test specimen has to be planed as well. The standards for the bullets, shooting distances and twist lengths must be applied according to table 1, paragraph 4.1. If the bullet velocities can t be achieved with the determined test barrel for the test level, larger firing chambers with defined sizes (cone and length) can be used. Attention has to be paid to avoid as much as possible deformation of the bullets through the use of progressive powder STANAG 2920 Method If the STANAG 2920 method is requested for the determination of V 50, the latest issue of this standard has to be used. This method however is not able to determine a variance for the determination of any penetration probabilities Method -KNB The advantage of the method -KNB is that every test proof firing can be analysed independently of the range of velocity and that in addition to V 50 (mean value) an estimate for the standard deviation can be calculated. Thereby, it is assumed that the probability of penetration is a continuous, normal function of the impact velocity. Along with the V 50 other safety levels (e.g. V 95 ) can be indicated. As sampling always only includes a finite number of events, the probability function has to be replaced by the relative frequency. Relative frequencies of continuous random variables can, however, only be estimated if a classification of velocities in specific class ranges is carried out (e.g. 5 or 10 m/s). The change of the relative page 18 of 29
19 class frequency f k and the mid-value of class interval v k * of a specific class k results in: V = v k f mean value V k s 2 2 ( v k - V50 ) fk = standard deviation f = ΔF = F - F change of the relative class frequency k k k+1 k 1 * * v = ( v + + v ) corresponding class velocity k 2 k 1 k From the results of a test firing, three areas can be identified (let F K be the relative penetration): Area 1: only stopped shots (F k = 0) Area 2: penetrations as well as stopped shots (0 F k 1) Area 3: only penetrations (F k = 1). In order to get a correct analysis, the following conditions have to be fulfilled: The minimal number of shots should be 16 (better 20 to 30) Every area must include at least 2 shots. This means that the shot with the lowest velocity may not be a penetration and the shot with the highest velocity must be a penetration. This condition is connected to the elementary form of the function of penetration probability, which tends to 0 for low values and to 1 for high values. If the central section is empty no determination of the variance is possible, because in this case s = 0. Between two neighbouring partitions there can t be more than one empty class of velocity. The use of the above given formulas results systematically in a standard deviation for low shot numbers (< 100) which is too small; therefore a correction depending on the number of shots is necessary: s corr = s [ ln ( n) ] Where n refers to the number of shots and ln to the natural logarithm. A form for the calculation of V 50 and of the standard deviation s corr can be found in attachment 2. The results (penetration DS or non-penetration KD ) have to be registered in the corresponding columns. The analysis is done according to the above formulas. page 19 of 29
20 Other safety levels than 50% can also be determined. This is done with the following relation (k p according to table 2): v = V50 + k p p s corr table 2: coefficients for safety levels p [%] k p page 20 of 29
21 6.5 Statistical risk analysis If for a ballistic protection the average penetration velocity (V 50 ) and the corresponding standard deviation s according to point is determined, risk analysis can be carried out via statistical methods Determination of critical velocity for a given penetration probability At a given penetration probability p the corresponding critical velocity v p of the ballistic protection is calculated with the following relation. This enables the direct comparison of this critical velocity to the maximum combat velocity given by the user: v = V50 + α s [m/s] p p corr Values for the number α p are compiled in table 3, according to the penetration probability. They originate from the standardised normal distribution. table 3: Numbers for the calculation of the critical velocity at a given penetration probability p α p Example: V 50 = 465 m/s S corr = 12.5 m/s The formula vp = v50 + α p scorr provides as critical velocity for the penetration probability p = 10-3 (1 penetration per 1000 shots): v p = = m/s Determination of the penetration probability at given impact velocity Determination of the penetration probability p v at a given maximum impact velocity v p enables to estimate the remaining risk. At known V 50 and known standard deviation s corr the penetration probability at the impact velocity v p can be calculated as follows: page 21 of 29
22 Determination of α p with: v - p V50 α p = [-] s korr Having α p the probability p v can be calculated according to the following formula: p v α p 1 - = P( α ) e 2 p = dx [-] 2 π 2 x or with the following table: Table 4: Penetration probability p v = P(v p ) as a function of α p e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e+00 Example: V 50 = 465 m/s s korr = 12.5 m/s The formula v p v 50 α p = provides for an impact velocity 420 m/s: s korr α p = According to table 4 the penetration probability at 420 m/s is: 1.59 x 10 4 One has to expect an average of about 1.6 penetrations per shots. page 22 of 29
23 6.6 Reference materials (Residual energy measurement) For the determination of the remaining energy transferred to the body behind a ballistic protection in case of a non-penetration, plastically malleable materials (plasticine), in which the volume of the indentation formed at the impact is proportional to the transmitted energy, are used. The residual energy behind a ballistic protection can be approximated by the determination of that volume. The proportionality factor between volume and energy is determined simultaneously with the determination of the plasticity of the plasticine by the ball drop method. Procedure For the calibration of the plasticine, the indentation depths of five falling weight tests are averaged. With this average value d m, which amounts 20 ± 2 mm, the maximum permitted volume V zul of the indentation can be determined with the help of the following formula: V zul = F E = ( d 1.13) E (d m in mm) [cm 3 ] zul m zul Example: If 70 J apply for the permitted energy transferred to the body and an average indentation depth of 20.5 mm was measured in terms of the plasticity measurement, the maximum permitted volume of the formed indentation behind the ballistic protection is as follows (rounding up to the next cm 3 ): V = ( ) 70 = = zul cm 3 Instead of the formula the following graphic chart can also be used for the determination of the factor F: F - factor Average indentation depth page 23 of 29
24 After the impact the beads arisen around the dent have to be removed flatly. Thereupon the dent is filled with water, the filled volume measured and compared with the permitted value determined above. page 24 of 29
25 7 Evaluation and documentation of the test 7.1 Evaluation of the test A test according to this guideline is considered as successful if the requirements of paragraph 4.1 are fullfilled. The test of the ballistic resistance is considered as failed if there is a penetration in accordance with definition paragraph Depending on the recorded result, the following definitions and/or the following abbreviations have to be used in the test report: om = Without marks BmRmL = Bulge with crack letting the light through (Penetration, if splinter in the plasticine) BmRoL = Bulge with crack not letting the light through (no penetration) BoR = Bulge without crack (no penetration) Ds = Penetration Ss = Bullet stopped inside specimen Apr = Ricochet GaO = Bullet left specimen on the impact side GaS = Bullet left specimen at the side NS = No-Splinters S = Splinter KP = No Penetration 7.2 Test report The test and the test result must be documented in the test report. This report must at least include the following details and statements: Name and address of the test centre Name and address of the submitter Manufacturer and place of manufacture of the test specimen Brand name and/or type designation of the test specimen Number and date of the test report Date of test specimen receipt Test date Construction, -size and number of test specimen as well as further relevant details (e.g. weight per unit area, thickness of test specimen) Details of the material, processing and batch number Details of the test requirements Details of the test specifications page 25 of 29
26 Deviations and restrictions as compared to the test requirements/test specifications Details about measuring inaccuracies (if required) as well as detected faults Measurements, analyses, derived results, tables, graphics, outlines and/or pictures Detection about penetration and/or other damages Remarks about special observations and detections during the test Statement that the test results refer exclusively to the test specimen Remarks about an eventually issued test certificate respectively test report Statement, that without approval of the test centre extracts of the test report in extracts may not be duplicated Name and signature of the responsible test officer 7.3 Test certificate/test confirmation If the result of the test is positive, then a test certificate is issued. Only the members of the are entitled to issue a test certificate according to this guideline. In the test certificate the test steps according to this guideline and requirements which are other and going beyond the guideline must be documented. If the test was not passed, then no test certificate is issued. The customer receives a test report. If the required test according to the customer s needs is carried out with a type of ammunition that is not classified according to table 1 (paragraph 4.1) of this guideline, he receives, provided that the test is positive, a test report and a written confirmation. From the test certificate/written confirmation it must be recognizable that it only applies to the tested sample. It includes at least the following details. Name and address of the test centre Name and address of the customer Manufacturer and place of manufacture of the test specimen Object and model number of the test specimen Details of the test requirements Classification according to table 1 (paragraph 4.1) Number and publication of the test certificate/written confirmation Number of the test report Date and place of the test Details about validity and distribution of the test certificate/written confirmation page 26 of 29
27 7.4 Validity test certificate/test confirmation The test certificate/test confirmation is only valid as far as products manufactured consecutively are identical with the tested sample. The validity expires, if changes or modifications of the production process, the materials or the quality management system, which can lead to an influence of the product conformity, are made or a following test yields a negative result. 7.5 Traceability of the results The customer has to ensure the storage of the test samples to establish of the traceability of the test results. 7.6 Details on material and material processing Details on material, construction, manufacturing method and the melt analysis for metals in accordance with EN have to be deposited at the testing institute. page 27 of 29
28 Attachment 1: Test set-up m, m or selectable max. 2,5 m min. 1 m shooting direction weapon test object V-measuring devise page 28 of 29
29 Attachment 2: Form for the determination of V 50 and standard deviation s Penetration velocity of protective materials Determination of average value and standard deviation Test object: Test threshold: 0,01% Class limit: 450 m/s Class width: 5 m/s Date: V u V o KD DS F k f k = ΔF k V k V 50 S [m/s] [m/s] [m/s ] [m/s] [m/s] ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0, ,00 0,00 0,0 0,0 0,00 Total 0 0 0,0 0,00 Average penetration velocity (v 50 ) : 0,0 m/s Standard deviation (s korr ) : 0,0 m/s % - critical velocity : 0,0 m/s Penetration probability. between 0 0 m/s 0,0E+00 page 29 of 29
Testing guideline. "special protected vehicles"
"" ( Sondergeschützte Fahrzeuge ) bullet resistance Englische Übersetzung; es gilt immer die deutsche Originalfassung! English translation; however the original German version always prevails! Publisher:
Technology Assessment Program NIJ Standard for Ballistic Helmets
Note to users: This electronic document is not subject to copyright. You may copy it, but you are requested not to disseminate altered copies. Technology Assessment Program NIJ Standard for Ballistic Helmets
Ship Security Bridge Vulnerability Study To determine the effects of weapons fired at the bridge of tankers and to recommend effective ship hardening
Ship Security Bridge Vulnerability Study To determine the effects of weapons fired at the bridge of tankers and to recommend effective ship hardening measures to mitigate the threat. October 2014 Issued
Ballistic protection Beat P. Kneubuehl
Ballistic protection Beat P. Kneubuehl Dr. sc. forens., M. in Math. Beat P. Kneubuehl, P.O. Box 760, CH-3603 Thun, Switzerland German edition: June 2000 English edition: December 2002 Revised: March 2003
History of Explosia a.s.
Propellants History of Explosia a.s. SINCE 1920 Production of smokeless powders, black powders and explosives in Explosia a.s. has a long tradition. The company was established in 1920 under the name Czechoslovak
Description of mechanical properties
ArcelorMittal Europe Flat Products Description of mechanical properties Introduction Mechanical properties are governed by the basic concepts of elasticity, plasticity and toughness. Elasticity is the
Lapua Ballistics User Guide
Lapua Ballistics User Guide 1 Lapua Ballistics User Guide Introduction Lapua Ballistics is advanced exterior ballistic software for mobile phones capable of predicting trajectories in real time with extreme
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Technical Report TR-05-2005 WARNING SHOT TARGET BALLISTIC TEST EVALUATION. Prepared for:
Technical Report TR-05-2005 WARNING SHOT TARGET BALLISTIC TEST EVALUATION. Prepared for: Canadian Police Research Centre National Research Council Canada 1200 Montreal Road Ottawa, ON K1A 0R6 Prepared
A Discussion on Performance, Recoil and Comparative Testing By Dave Emary, Hornady Senior Ballistician
A Discussion on Performance, Recoil and Comparative Testing By Dave Emary, Hornady Senior Ballistician Superformance ammunition achieves the highest performance of any ammunition on the market today; 100-200
INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999
INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS Published: April 1999 CONTENTS 1 Introduction 2 Test Procedures General 3 Standards and Specific Test Procedures
APIB Test Specification No. 09 WATERPROOFING MEMBRANES SWISS HAIL IMPACT PROTECTION REGISTER HSR. 01.07.2015 / 07-15en Version 1.
Association of Public Insurance Companies (APIB) Association des établissements cantonaux d assurance incendie SWISS HAIL IMPACT PROTECTION REGISTER HSR APIB Test Specification No. 09 WATERPROOFING MEMBRANES
CHAPTER 6 WEAR TESTING MEASUREMENT
84 CHAPTER 6 WEAR TESTING MEASUREMENT Wear is a process of removal of material from one or both of two solid surfaces in solid state contact. As the wear is a surface removal phenomenon and occurs mostly
Impact Resistance of Guards on Grinding Machines
International Journal of Occupational Safety and Ergonomics (JOSE) 211, Vol. 17, No. 4, 411 421 Impact Resistance of Guards on Grinding Machines Detlef Mewes Olaf Mewes Institut für Arbeitsschutz der Deutschen
Removing chips is a method for producing plastic threads of small diameters and high batches, which cause frequent failures of thread punches.
Plastic Threads Technical University of Gabrovo Yordanka Atanasova Threads in plastic products can be produced in three ways: a) by direct moulding with thread punch or die; b) by placing a threaded metal
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (12) 77 7R QUALIFICATION OF EQUIPMENT ANNEX 8: QUALIFICATION OF BALANCES Full document title and reference Document type Qualification
JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes
JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes 1. Scope This Japanese Industrial Standard specifies the electric resistance welded carbon steel tubes, hereinafter
Chapter Outline. Mechanical Properties of Metals How do metals respond to external loads?
Mechanical Properties of Metals How do metals respond to external loads? Stress and Strain Tension Compression Shear Torsion Elastic deformation Plastic Deformation Yield Strength Tensile Strength Ductility
ENGLISH FORK GUIDE 2013
FORK GUIDE 2013 ENGLISH 1 With a brand which is synonymous with specialists in forest products handling attachments, BOLZONI AURAMO offers its expertise and market leading attachments for all requirements,
D013 S011 S015 D032 S020 D036 D037.1 D037.2
LOVEX powders for pistols and revolvers CALIBRES D013 S011 S015 D032 S020 D036 D037.1 D037.2 7.6 x 25 TOKAREV.380 AUTO 9 mm LUGER.38 SPECIAL.357 MAGNUM.357 SIG.40 S&W.44 REMINGTON MAG..45 ACP LOVEX powders
Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM
Force measurement Forces VECTORIAL ISSUES In classical mechanics, a force is defined as "an action capable of modifying the quantity of movement of a material point". Therefore, a force has the attributes
Test Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports. Report number C 1395-1E-RA-003 d.d. May 14, 2014 Fire-resistant barriers: background on requirements
Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note
Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates Application Note l Introduction The split post dielectric resonator (SPDR) provides an accurate technique for measuring
The Effect of Forced Air Cooling on Heat Sink Thermal Ratings
zpero 1 The Effect of Forced Air Cooling on Heat Sink Thermal Ratings By Paul Bachman, Fellow Engineer & Ronnie Haiduk, Applications Engineer, Crydom, Inc. ABSTRACT A heat sink s ability to dissipate thermal
Quality Regulations for Profiles
Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3
ARMORED JEEP GRAND CHEROKEE Typically Armored to Level A9/B6+ Against 7.62x39, 5.56x45, 7.62x51, M193, & M80 ball. Can be Armored to Any Level.
ARMORED JEEP GRAND CHEROKEE Typically Armored to Level A9/B6+ Against 7.62x39, 5.56x45, 7.62x51, M193, & M80 ball. Can be Armored to Any Level. BASE VEHICLE SPECIFICATIONS MAKE: MODEL: YEAR: ENGINE: POWER:
Mechanical and electronic length measuring instruments for internal and external measurements
echanical and electronic length measuring instruments for internal and external measurements Precision and continuity Features Contents ver since its foundation in 1883 Kroeplin have been involved in development
Guidelines on the Calibration of Static Torque Measuring Devices
European Association of National Metrology Institutes Guidelines on the Calibration of Static Torque Measuring Devices EURAMET cg-14 Version.0 (03/011) Previously EA-10/14 Calibration Guide EURAMET cg-14
Morini CM 162EI. Technical Data
Morini CM 162EI Technical Data Caliber: Weight: Total Length: Total Height: Total Width: Length of Sight Line: Barrel Length: Type of Barrel: Number of Riflings: Functioning: Trigger: Path: Arrest Point:
English version. Raised access floors
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM EN 12825 August 2001 ICS 91.060.30 English version Raised access floors Planchers surélevés Doppelböden This European Standard was approved by CEN on
Technical information
Technical information Toughened and laminated safety glasses GLASS UNLIMITED Sommaire 1. INTRODUCTION 1. Introduction 3 2. Laminated glass 4 3. Thermally toughened glass 6 4. European classification standards
Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards
Using Equotip Hardness Test Blocks Heinz-Horst Pollok, consultant for material testing and instrument electronics (Cologne, Germany) Dr. Ralph T. Mennicke, product manager for material testing, Proceq
High speed machining and conventional die and mould machining
High speed machining and conventional die and mould machining Reprint from HSM - High Speed Machining There are a lot of questions about HSM today and many different, more or less complicated, definitions
In mathematics, there are four attainment targets: using and applying mathematics; number and algebra; shape, space and measures, and handling data.
MATHEMATICS: THE LEVEL DESCRIPTIONS In mathematics, there are four attainment targets: using and applying mathematics; number and algebra; shape, space and measures, and handling data. Attainment target
Confidence Intervals for One Standard Deviation Using Standard Deviation
Chapter 640 Confidence Intervals for One Standard Deviation Using Standard Deviation Introduction This routine calculates the sample size necessary to achieve a specified interval width or distance from
PENETRATION OF BITUMINOUS MATERIALS
NANYANG TECHNOLOGICAL UNIVERSITY School of Civil and Structural Engineering LABORATORY - PAVEMENT MATERIALS PENETRATION OF BITUMINOUS MATERIALS OBJECTIVES To examine the consistency of a sample of bitumen
108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
Physics Lab Report Guidelines
Physics Lab Report Guidelines Summary The following is an outline of the requirements for a physics lab report. A. Experimental Description 1. Provide a statement of the physical theory or principle observed
Ballistic protection against armour piercing projectiles using titanium base armour
Ballistic protection against armour piercing projectiles using titanium base armour Diederen, A.M. 1, Broos, J.P.F. 1, Trigt, S.N. van 1, Peijen, M.C.P. 2 1 TNO Prins Maurits Laboratory, P.O. Box 45, NL-2280
AS COMPETITION PAPER 2008
AS COMPETITION PAPER 28 Name School Town & County Total Mark/5 Time Allowed: One hour Attempt as many questions as you can. Write your answers on this question paper. Marks allocated for each question
The Determination of Uncertainties in Charpy Impact Testing
Manual of Codes of Practice for the Determination of Uncertainties in Mechanical Tests on Metallic Materials Code of Practice No. 06 The Determination of Uncertainties in Charpy Impact Testing M.A. Lont
Lab 8: Ballistic Pendulum
Lab 8: Ballistic Pendulum Equipment: Ballistic pendulum apparatus, 2 meter ruler, 30 cm ruler, blank paper, carbon paper, masking tape, scale. Caution In this experiment a steel ball is projected horizontally
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes
Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to
How To Test A Rockwell Type Hardness Tester
ROCKWELL TYPE HARDNESS TESTER CV-600A TM Ready-to-test analogue Rockwell type tester with lever system for direct load application Basic regular Rockwell type tester offering accuracy, reliability and
SFI SPECIFICATION 61.1 EFFECTIVE: FEBRUARY 26, 2014
SFI SPECIFICATION 61.1 EFFECTIVE: FEBRUARY 26, 2014 PRODUCT: Turbochargers 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating and
Test Report No. C926LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: AMK-Collectra AG Bahnweg Nord
COMMUNICATING using MEASUREMENTS In Engineering we use a great many measuring instruments.
COMMUNICATING using MEASUREMENTS In Engineering we use a great many measuring instruments. Scales Verniers Micrometers Gauges Comparators Thermometers Thermistors + Indicator Thermocouples + Indicator
Gravimetric determination of pipette errors
Gravimetric determination of pipette errors In chemical measurements (for instance in titrimetric analysis) it is very important to precisely measure amount of liquid, the measurement is performed with
European Technical Approval ETA-06/0259
European Technical Approval ETA-06/0259 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and
Experiment #1, Analyze Data using Excel, Calculator and Graphs.
Physics 182 - Fall 2014 - Experiment #1 1 Experiment #1, Analyze Data using Excel, Calculator and Graphs. 1 Purpose (5 Points, Including Title. Points apply to your lab report.) Before we start measuring
North American Stainless
North American Stainless Long Products Stainless Steel Grade Sheet 2205 UNS S2205 EN 1.4462 2304 UNS S2304 EN 1.4362 INTRODUCTION Types 2205 and 2304 are duplex stainless steel grades with a microstructure,
SFI SPECIFICATION 4.1 EFFECTIVE: MARCH 27, 2013 *
SFI SPECIFICATION 4.1 EFFECTIVE: MARCH 27, 2013 * PRODUCT: Automatic Transmission Shields 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for
PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany
ABSTRACT: PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany Today, in-line inspection tools are used routinely
Point Blank Zero. Fast Shots versus Precision Hits. By Major John L. Plaster, USA (ret)
Point Blank Zero Fast Shots versus Precision Hits By Major John L. Plaster, USA (ret) The fastest way to get off an effective shot is to set your scope s elevation for a Point Blank Zero. When done properly,
SFI SPECIFICATION 14.21 EFFECTIVE: FEBRUARY 26, 2014 *
SFI SPECIFICATION 14.21 EFFECTIVE: FEBRUARY 26, 2014 * PRODUCT: Screw-Type Supercharger Restraint Devices 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum
Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual
BR BO-01-02 Effective from June 1, 2000 Revision: March 26, 2002 Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual (Unofficial Manual) Technical Appraisal Department, Building
Technical Procedure for Integrated Ballistics Identification System (IBIS)
Technical Procedure for Integrated Ballistics Identification System (IBIS) 1.0 Purpose To outline the procedures for use of the Integrated Ballistics Identification System (IBIS). 2.0 Scope This procedure
Chapter 19. Mensuration of Sphere
8 Chapter 19 19.1 Sphere: A sphere is a solid bounded by a closed surface every point of which is equidistant from a fixed point called the centre. Most familiar examples of a sphere are baseball, tennis
PROPERTIES OF MATERIALS
1 PROPERTIES OF MATERIALS 1.1 PROPERTIES OF MATERIALS Different materials possess different properties in varying degree and therefore behave in different ways under given conditions. These properties
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
Test Report No. C1319LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Thermics S.r.l. Via dell'olmo
LABORATORY EXPERIMENTS TESTING OF MATERIALS
LABORATORY EXPERIMENTS TESTING OF MATERIALS 1. TENSION TEST: INTRODUCTION & THEORY The tension test is the most commonly used method to evaluate the mechanical properties of metals. Its main objective
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043
Nikon BDC Reticle. Guide to using. Instruction manual. Nikon Inc. 1300 WALT WHITMAN ROAD, MELVILLE, NEW YORK 11747-3064, U.S.A.
Guide to using Nikon BDC Reticle Nikon Inc. 1300 WALT WHITMAN ROAD, MELVILLE, NEW YORK 11747-3064, U.S.A. Edited by NIKON VISION CO., LTD. Printed in the Philippines (702C)2E/1110 Instruction manual E
Impact testing ACTIVITY BRIEF
ACTIVITY BRIEF Impact testing The science at work Impact testing is of enormous importance. A collision between two objects can often result in damage to one or both of them. The damage might be a scratch,
Projectile Motion 1:Horizontally Launched Projectiles
A cannon shoots a clown directly upward with a speed of 20 m/s. What height will the clown reach? How much time will the clown spend in the air? Projectile Motion 1:Horizontally Launched Projectiles Two
EN 14904. Export Manager Pulastic Sports Surfaces The Netherlands www.descol.nl
Introduction by : Peter Minnée Export Manager Pulastic Sports Surfaces The Netherlands www.descol.nl Co-operation between European test institutes and standardization institutes formalized in 1961 Construction
GUIDELINES FOR TESTING FRESH SELF-COMPACTING CONCRETE
Growth Contract No. GRD2-2000-30024 GUIDELINES FOR TESTING FRESH SELF-COMPACTING CONCRETE Principal author: G. DE SCHUTTER September 2005 European Research Project: MEASUREMENT OF PROPERTIES OF FRESH SELF-COMPACTING
Experimental Uncertainties (Errors)
Experimental Uncertainties (Errors) Sources of Experimental Uncertainties (Experimental Errors): All measurements are subject to some uncertainty as a wide range of errors and inaccuracies can and do happen.
GK Packing System Welding Instructions
GK Packing System Welding Instructions Roxtec GmbH Neuer Höltigbaum 1-3, 22143 Hamburg GERMANY Tel +49 (040) 657398-0, Fax +49 (040) 657398-50 EMAIL [email protected], www.roxtec.de Welding instructions
High Capacity Hot Air Dryer
High Capacity Hot Air Dryer MADE IN AUSTRIA autumn 2015 www.zimmer-austria.com page 1 Hot air dryer type: Compact HC The modular construction of the high efficiency and powerful hot air nozzle dryer is
Measuring instruments in industry.
Measuring instruments in industry. Measuring instruments that are present in any branch of industry, are subject to different levels of supervision, like in case of laboratories. Supervision relates to
Thank you for inviting us to participate and the opportunity to give you a basic overview and specifics of the instrument for ballistic evidence
Thank you for inviting us to participate and the opportunity to give you a basic overview and specifics of the instrument for ballistic evidence finding - the Evofinder, produced by ScannBI Technology.
EVALUATION OF KINETIC-ENERGY NON-LETHAL WEAPONS
23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 EVALUATION OF KINETIC-ENERGY NON-LETHAL WEAPONS A. Papy 1,2 and M. C. Pirlot 1 1 Royal Military Academy, Department of Weapon
SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *
SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied
Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied Stress and strain fracture or engineering point of view: allows to predict the
11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07
In-process control In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07 Here you will find answers to the following questions: What are the in-process control tasks? Where
NATIONAL ASSESSMENT GUIDELINE FOR THE KOMO PROCESS CERTIFICATE FOR THE INSTALLATION OF FACADE CLADDING USING ADHESIVE SYSTEMS
BRL 4104 01-02-2003 NATIONAL ASSESSMENT GUIDELINE FOR THE KOMO PROCESS CERTIFICATE FOR THE INSTALLATION OF FACADE CLADDING USING ADHESIVE SYSTEMS Accepted by the Harmonisatie Commissie Bouw of the Stichting
NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)
NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning) Summary of Results Standardized Thermal Transmittance (U-Factor)
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
Test equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
Measuring Bullet Velocity with a PC Soundcard
Measuring Bullet Velocity with a PC Soundcard Michael Courtney and Brian Edwards Abstract: This article describes a simple method for using a PC soundcard to accurately measure bullet velocity. The method
METHODOLOGY OF LOCK CYLINDER TESTING BY THE BUMPING NON-DESTRUCTIVE METHOD
CERTIFICATE ON CERTIFICATION OF EXPERTISE GIVEN BY THE EXPERT IN THE FIELD OF: SPECIALIZED SPECIALIZATION OF LOCK AND SECURITY EQUIPMENT No.: MISCELLANEOUS TECHNICAL FIELDS METHODOLOGY OF LOCK CYLINDER
Morini CM 22M. Technical Data
Morini CM 22M Technical Data Caliber: Weight: Total Length: Total Height: Total Width: Length of Sight Line: Barrel Length: Number of Riflings: Trigger: 1 st stage weight: 2 nd stage weight: Sight: Sight
JIS G3445 Carbon steel tubes for machine structural purposes
JIS G3445 arbon steel tubes for machine structural purposes 1. Scope This Japanese Industrial Standard specifies the carbon steel tubes, hereinafter referred to as the "tubes", used for machinery, automobiles,
The Swedish Squad Support Weapon Program
Product Manager Small Arms Systems The Swedish Squad Support Weapon Program Presentation to NDIA 50 th Joint Services Small Arms Symposium Las Vegas, May 11, 2004 Per G. Arvidsson Product Manager Small
= δx x + δy y. df ds = dx. ds y + xdy ds. Now multiply by ds to get the form of the equation in terms of differentials: df = y dx + x dy.
ERROR PROPAGATION For sums, differences, products, and quotients, propagation of errors is done as follows. (These formulas can easily be calculated using calculus, using the differential as the associated
Ballistic Resistance of Body Armor NIJ Standard-0101.06
JULY 08 U.S. Department of Justice Office of Justice Programs National Institute of Justice STANDARDS Ballistic Resistance of Body Armor NIJ Standard-0101.06 www.ojp.usdoj.gov/nij U.S. Department of Justice
VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz. Quit
VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz Quit Theory and Practice of Wear Definition In materials science, wear is the erosion of material from a solid
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Design qualification and type approval of PV modules
Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance
Keywords: Torque, calibration, uncertainty, torque tools, torque testers. Contents
Measurement uncertainty in torque calibration Luca G. Bochese, ASQ CQE, CRE (Boch - Milano), [email protected], www.boch.net Dr. A. Bochese ( Feanor - Tallinn), [email protected], www.feanor.com Keywords: Torque,
Silicon temperature sensors. Other special selections are available on request.
Rev. 05 25 April 2008 Product data sheet 1. Product profile 1.1 General description The temperature sensors in the have a positive temperature coefficient of resistance and are suitable for use in measurement
(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
Construction of a Fencing Mask
Academy of Historical Arts & HEMAC Construction of a Fencing Mask Author: Keith Farrell Version: 01 Date: 5th May 2012 Version and Copyright Information Version: 01 Date: 5th May 2012 Research: Copyright