1000 Series. Electronic Digital Actuators. Table of Contents
|
|
|
- Leslie Miller
- 9 years ago
- Views:
Transcription
1 Instruction Manual IM Series Electronic Digital Actuators Table of Contents General Information Product Specifications... 4 Physical Installation... 5 MV-1000 Component Indentification... 6 MV-1000 Speed/Thrust Curve... 6 MV-1000 Major Dimensions SM-1000 Component Indentification... 9 SM-1000 Speed/Torque Curves SM-1000 Major Dimensions LA-1000 Component Indentification LA-1000 Speed/Thrust Curve LA-1000 Major Dimensions VA-1000 Component Indentification VA-1000 Speed/Thrust Curve VA-1000 Major Dimensions Installation Wiring DIP Switch Configuration Start-up Information Lower PC Board Diagram Typical Wiring Diagram Troubleshooting Guide Due to wide variations in the terminal numbering of actuator products, actual wiring of this device should follow the print supplied with the unit. -1-
2
3 INTRODUCTION Jordan Controls, Inc., designs, manufactures, and tests its products to meet many national and international standards. For these products to operate within their normal specifications, they must be properly installed and maintained. The following instructions must be followed and integrated with your safety program when installing and using Jordan Controls products: Read and save all instructions prior to installing, operating and servicing this product. If you don t understand any of the instructions, contact Jordan Controls for clarification. Follow all warnings, cautions and instructions marked on, and supplied with, the product. Inform and educate personnel in the proper installation, operation and maintenance of the product. Install equipment as specified in Jordan Controls installation instructions and per applicable local and national codes. Connect all products to the proper electrical sources. To ensure proper performance, use qualified personnel to install, operate, update and maintain the unit. When replacement parts are required, ensure that the qualified service technician uses replacement parts specified by Jordan Controls. Substitutions may result in fire, electrical shock, other hazards, or improper equipment operation. Keep all product protective covers in place (except when installing, or when maintenance is being performed by qualified personnel), to prevent electrical shock, personal injury or damage to the actuator. Operation of actuator in an inappropriate fashion may cause harm or damege to unit or other equipment/surroundings WARNING Before installing the actuator, make sure that it is suitable for the intended application. If you are unsure of the suitability of this equipment for your installation, consult Jordan Controls prior to proceeding. WARNING - SHOCK HAZARD Installation and servicing must be performed only by qualified personnel. GENERAL INFORMATION -2- WARNING - ELECTROSTATIC DISCHARGE This electronic control is static-sensitive. To protect the internal components from damage, never touch the printed circuit cards without using electrostatic discharge (ESD) control procedures. LA units must only be cleaned with a damp cloth. RECEIVING/INSPECTION Carefully inspect for shipping damage. Damage to the shipping carton is usually a good indication that it has received rough handling. Report all damage immediately to the freight carrier and Jordan Controls, Inc. Unpack the product and information packet taking care to save the shipping carton and any packing material should return be necessary. Verify that the items on the packing list or bill of lading agree with your own. STORAGE If the product will not be installed immediately, it should be stored in a clean, dry area where the ambient temperature is -13 to 131 F (-25 to 55 C). The actuator should be stored in a non-corrosive environment. The actuator is not sealed to NEMA 4 until the conduit entries are properly connected. EQUIPMENT RETURN A Returned Goods authorization (RG) number is required to return any equipment for repair. This must be obtained from Jordan Controls. (Telephone: 414/ ) The equipment must be shipped, freight prepaid, to the following address after the RG number is issued: Jordan Controls, Inc West Douglas Avenue Milwaukee, Wisconsin Attn: Service Department To facilitate quick return and handling of your equipment, include: 1. RG Number on outside of box 2. Your Company Name, Contact Name, Phone/Fax 3. Address 4. Repair Purchase Order Number 5. Brief description of the problem
4 GENERAL INFORMATION IDENTIFICATION LABEL An identification label is attached to each actuator cover. When ordering parts, requesting information or service assistance, provide all of the label information. MODEL: MV / 5 / E03 WIRING DIA: Jordan Controls Inc WEST DOUGLAS AVENUE MILWAUKEE, WISCONSIN (414) Fax:(414) [email protected] LAST TWO DIGITS OF SERIAL NUMBER SERIAL: DENOTE YEAR OF MANUFACTURE V: 115/230 Hz: 50/60 PH: 1 A: 1 95C CUSTOMER P/N: CERTIFICATE No: SIRA02ATEX1188 JORDAN P/N: EExd IIB T4 Ta = -40 C to +85 C Enclosure IP6X 0518 II2GD WARNINGS: DO NOT OPEN WHILE A FLAMMABLE GAS AND/OR DUST ATMOSPHERE IS PRESENT CABLE ENTRIES CAN REACH 122 C IN AN AMBIENT OF 85 C ALL CABLE ENTRIES TAPPED NPT! Battery Backup Option. (4-20 ma only) This external option provides battery backup power to the actuator along with a generated 4-20 ma command signal. When AC power is lost, the potentiometer adjustable command signal positions the actuator. After completing the positioning cycle, the battery unit enters a power conserving cycle to extend available power. When AC power is restored, the circuitry resets to automatic control. There is enough reserve power to position the actuator multiple times without a charge period. A fully discharged battery will take hours to recharge. A battery OK, open transistor, low-level logic output signal is provided to indicate when battery voltage has fallen below operating levels. Incremental Control Option. This option allows switched AC or DC line power to position the actuator. A MODEL NUMBER: MV1020 Actuator Series SERIAL NUMBER: 1234 E 03 Sequential Number COMPANY Year Built Month Built P/N 53B GENERAL ACTUATOR DESCRIPTION The 1000 Series are full-featured actuators with the capability to accept analog control signals. The design provides smooth, highly accurate positioning, with positive position-lock when not in motion. These rugged actuators may be mounted in any position and will withstand the most adverse environmental conditions. A stepper motor produces torque, which is transmitted to the output shaft through a gear or drive screw arrangement. This allows the low torque, high speed motor output to be converted to high torque, low speed for actuator output shaft motion. The built-in servo drive amplifier controls the stepper motor s speed and direction. It also controls actuator end limits, motor torque, deadband and 4-20 ma transmitter. Signal Conversion Module Option. This option is used to accept up to four actuator open collector limit switch inputs and convert them to four form C relay output contacts. The module is furnished in one enclosure, for close-coupled mounting to the actuator. Gearbox Option. (SM-1020 only) The gearbox is factory installed to the SM-1020 output shaft to increase torque output. -3- ABBREVIATIONS USED IN THIS MANUAL A or Amps Ampere ac Alternating Current C Degrees Celsius CW Clockwise CCW Counterclockwise dc Direct Current F Degrees Fahrenheit G Earth Ground Hz Hertz kg Kilogram L Line (power supply) lbs Pounds lbf. Lbs. Force LVDT Linear Variable Differential Transformer ma Milliamp mfd Microfarad mm Millimeters N Newton (force) NEMA National Electrical Manufacturing Assoc. Nm Newton Meter NPT National Pipe Thread Ph Phase PL Position Limit Switch P/N Part Number RPM Revolutions per Minute SEC Second TL Thrust Limit Switch Vac Volts ac Vdc Volts dc VR Variable Resistance W Watt WARRANTY INFORMATION Warranty: Subject to the following, Jordan expressly warrants the products manufactured by it as meeting the applicable Jordan product specifications and that such products are free from defects in material and workmanship for a period of one (1) year from the date of delivery. The foregoing is the sole and exclusive warranty made by Jordan with respect to the products. Jordan makes no other warranties, either express or implied (including, without limitation, warranties as to merchantability or fitness for a particular purpose). The purchaser retains responsibility for the application and functional adequacy of the offering. See Jordan s General Conditions of Sale - Product, for complete warranty information.
5 Standard Line Voltage: 120/240 Vac, ±10%, 50/60 Hz (Slide switch select). Supply voltage fluctuations up to 10% of the nominal volatge Optional Line Voltage: SM-1015, MV-1010, VA Vdc SM-1020, LA-1020, MV-1020, VA Vdc SM-1020, LA-1020, MV-1020, VA Vdc Power: SM-1015, LA-1010, MV-1005, MV-1010, VA VA SM-1020, LA-1020, MV-1020, VA VA Command Signal Inputs: 4-20 ma, 4-12 ma, ma 0-5 Vdc 0-10 Vdc Incremental contact closures Position Feedback Signal: Isolated 4-20 ma, loop powered with Vdc external power supply Field Wiring Terminations: Plugable terminal block, wire size range AWG Command Signal Monitor: (current command only) The 1000 series loss-of-signal circuitry monitors the command signal input. If the command signal drops below 3.2 ma or above 20.7 ma, the actuator will either lock in place or run to a preset position (user selectable). Limit Signals: Internal: Part of servo control External: Open transistor low level logic outputs, adjustable over stroke range. Rating: 40 Vdc at 40 ma maximum. For customer use, not part of servo control. Current Limit: Automatic adjusting of the motor current limit (internal to servo control). Speed/Force: See speed/force curves. Output Shaft Motion: All models can go either direction on an increasing command signal. This is determined by the ZERO and SPAN settings. SPECIFICATIONS Rotation: SM models without gearbox: 90 to 2 turns or 2 to 20 turns. Infinitely adjustable within range. SM models with gearbox: 30 to 153 or 150 to 4.25 turns. Infinitely adjustable within range. Stroke: LA models: in. ( mm) MV models: in. ( mm) VA models: in. (9-38 mm) All models infinitely adjustable within range. Weight: (Not including devices mounted to actuator) SM-1015: 12 lbs. (5.4 kg) SM-1020: 16 lbs. (7.3 kg) SM-1020 with gearbox: 19 lbs. (8.6 kg) LA-1020: 16 lbs. (7.3 kg) MV-1005: 12 lbs. (5.4 kg) MV-1010: 12 lbs. (5.4 kg) MV-1020: 16 lbs. (7.3 kg) VA-1010: 20 lbs. (9.1 kg) VA-1020: 24 lbs. (10.9 kg) Conduit Entry: 1/2 NPT Handwheel: Push to engage, spring return on release. (Not available with MV-1005) Temperature Limits: -40 F to 150 F (-40 C to 65 C) Humidity: 50% maximum at 104 F (40 C) Altitude: Up to 3,280 ft. (1000 m) above mean sea level Pollution Degree: 2 Installation Category: II Enclosure: Explosion-proof for Class I, Division 1, Groups C and D. Type 4 (IP65), indoor or outdoor Duty Cycle: Unrestricted modulating duty. (Cont. duty) Position Accuracy: 1% of full range Deadband: Factory preset to 1%. Field adjustable. -4-
6 PHYSICAL INSTALLATION ACTUATOR CHARACTERISTICS The actuator output shaft is made of stainless steel and the housing is aluminum. The actuator housing may be ATEX 94/9/EC approved to group II, category 2 for dust and gas potentially explosive atmospheres. Vibration Limits: 4-15 ±.1 mm amplitude max. Enclosure Materials: The actuators are manufactured from alluminum alloy with stainless steel shafts, oilite bronze bushes and carbon steel fasteners. All external seals are manufactured from Nitrile which are suitable for use in an ambient temperature range of -40 C to +85 C. The user must ensure that the operating environment and any materials surrounding the actuator cannot lead to a reduction in the safe use of, or the protection afforded by, the actuator. Where appropriate the user must ensure the actuator is suitable protected against its operating environment. SPARE PARTS Spare parts and spare parts lists can be obtained by contacting the Jordan Controls Service Department. WARNING - SHOCK HAZARD EXPLOSIONPROOF and DUST IGNITIONPROOF ACTUATORS are not explosionproof or dustignitionproof until final installation is complete. Hazardous location enclosures must be installed in accordance with The National Electric Code requirements as well as state and local codes. ATEX approved actuators must be installed in accordance with EN , Electrical apparatus for explosive atmospheres, Part 14. Electrical installations in hazardous areas (other than mines). MAINTENANCE Jordan Controls actuators are maintenance free. It is recommended that you remove the cover and visually inspect the actuator on an annual basis. Maintenance must be performed only by qualified personnel. Voltages hazardous to your health are applied to these actuators. De-energize all sources of power before removing actuator cover. Failure to follow these precautions may result in serious injury or death. ATEX approved actuators must be repaired and overhauled in accordance with EN , Electrical apparatus for explosive atmospheres, Part 19. Repair and overhaul for apparatus used in explosive atmospheres (other than mines). Lubrication: The gearing is permanently lubricated. Re-lubrication is only required during repairs to the power gearing. The bronze bushings are lubricated with a few drops of SAE-10 or 20 NON-DETER- GENT oil. Re-lubricate when repairs are made. ELECTRICAL SUPPLY REQUIREMENTS An overcurrent protective device is required for the supply power. Size the overcurrent device per requirements of actuator for 125% of maximum rated load. Disconnect for the supply power is to be supplied by the customer. Wire conductor type and size should match Jordan Controls requirements, wiring diagrams and follow local codes. -5-
7 MV-1000 SERIES COMPONENT IDENTIFICATION MV-1000 SERIES SPEED/THRUST CURVE MV-1005 & MV-1010 MV-1020 To calculate shift time (total stroke), use this formula: Shift time (sec.) = Total stroke in inches Stroke rate of actuator in in./sec. Example: 1.25 inch stroke, 150 lbf thrust = 6.6 sec. -6-
8 MV-1000 SERIES MAJOR DIMENSIONS Threaded Base INCHES MILLIMETERS These dimensions are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available on request. -7-
9 MV-1000 SERIES MAJOR DIMENSIONS Cast Yoke Base INCHES MILLIMETERS MV-1010 MV-1020 A B C D E F G H (290.3) (314.2) 5.25 (133.4) 6.13 (155.7) 3.40 (86.4) 3.53 (89.7) 6.52 (165.6) 6.64 (168.7) 5.39 (136.9) 5.66 (143.8) 2.69 (68.3) 2.83 (71.9) 7.12 (180.8) 8.00 (203.2) 2.37 (60.2) 2.50 (63.5) These dimensions are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available on request. -8-
10 SM-1000 SERIES COMPONENT IDENTIFICATION Optional Gearbox -9-
11 SM-1000 SERIES SPEED/TORQUE CURVES To calculate shift time (total stroke), use this formula: Shift time (sec.) = Maximum revolutions for total range x 60 Revolutions per minute Example: 90 rotation at 1 rpm, 80 in. lbs. torgue 0.25 x 60 1 = 15 sec. SM-1015 SM-1020 NOTE: On models operating in the Vdc range, maximum output torque is limited to 29 in. lbs. There is no rating change when input voltage is 24 Vdc or greater. SM-1020 With Gearbox NOTE: On models with optional gearbox operating in the Vdc range, maximum output torque is limited to 125 in. lbs. There is no rating change when input voltage is 24 Vdc or greater. -10-
12 SM-1000 SERIES MAJOR DIMENSIONS SM-1015 & SM-1020 INCHES (MILLIMETERS) These dimensions are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available on request. -11-
13 SM-1000 SERIES MAJOR DIMENSIONS SM-1020 with Gearbox INCHES (MILLIMETERS) These dimensions are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available on request. -12-
14 SM-1000 MAJOR DIMENSIONS Optional Group B Enclosure INCHES (MILLIMETERS) These dimensions are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available on request. -13-
15 LA-1000 SERIES COMPONENT IDENTIFICATION LA-1000 SERIES SPEED/THRUST CURVE To calculate stroke time of LA-1020 with speed/thrust of 30/50, use: Total stroke in inches (mm) x 60 Stroke time (sec.) = Speed of actuator in inches/min. (mm/min.) Example: 6 x 60 6 inch stroke = = 12 sec
16 LA-1000 MAJOR DIMENSIONS INCHES (MILLIMETERS) STROKE A B C (19-76) (314) 7.69 (195) 4.69 (119) 3-6 (76-152) (441) (297) 5.69 (145) 6-9 ( ) (568) (399) 6.69 (170) 9-12 ( ) (695) (500) 7.69 (195) ( ) (882) (602) 8.69 (221) ( ) (1076) (805) (272) These dimensions are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available on request. -15-
17 VA-1000 SERIES COMPONENT IDENTIFICATION VA-1000 SERIES SPEED/THRUST CURVE To calculate shift time (total stroke), use this formula: Shift time (sec.) = Total stroke in inches Stroke rate of actuator in in./sec. Example: 0.75 inch stroke, 400 lbf thrust 0.75 = 30 sec. (VA-1020) = 44.1 sec. (VA-1010) NOTE: On models operating in the Vdc range, maximum output thrust is limited to 423 lbf. There is no rating change when input voltage is 24 Vdc or greater.
18 VA-1000 MAJOR DIMENSIONS INCHES (MILLIMETERS) VA-1015 VA-1020 A B C D E F G H I 18.9 (480.06) 21.3 (541.02) 7.35 (186.69) 8.25 (209.55) 7.13 (181.1) 8.00 (203.2) 5.25 (133.35) 5.5 (139.7) 2.63 (66.8) 2.75 (69.85) 2.38 (60.45) 2.5 (63.5) 3.00 (76.20) 3.5 (88.9) 5.25 (133.35) 5.75 (146.05) 1.75 (44.45) 2.00 (50.8) These dimensions are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available on request. -17-
19 GENERAL All wiring should be done in accordance with prevailing codes by qualified personnel. Typical wiring diagrams are shown on page 8. Actual wiring should follow the print supplied with the actuator. Fusing must be installed in line power, and should be of the slow blow type. Recommend 1 amp for ac input models and 5 amp for dc input models. Wiring should be routed to the actuator through one of the two 1/2 inch conduit openings. Generally, one conduit will contain input power and earth ground wires. The other conduit would then contain low level input and output signal wiring. It is recommended that all low level signal wiring be a shielded type with the shield grounded at source common. After installation, it is recommended that all conduits be sealed to prevent water damage. INSTALLATION WIRING Strip 0.22 inch (5.6mm) of insulation from the wire and insert this bare end into the appropriate terminal location, utilizing an insertion tool or a small screwdriver. Maximum recommended wire size is 14 AWG, and minimum is 26 AWG. WIRING TO TB1 Input power terminates at TB1. For ac models, terminal 1 is line, and terminal 2 is neutral. For dc models, terminal 1 is positive (+), and terminal 2 is negative (-). Terminal strip tabs are pressed down to insert wires. WIRING TO TB2 LS1 and LS2 may be used as optional end of travel limit switches. The incoming power supply earth ground should be securely connected to the green ground screw located inside the actuator base between the two conduit entries. WIRING TO TB3 If LS1, LS2, LS3 and LS4 are used as auxiliary position limit switches, connection is to terminals 1 through terminal 4. Maximum voltage is 40 Vdc and maximum current is 40 ma ma position feedback signal wires connect to terminals 9 (+) and 10 (-). Increasing command signal will result in an increasing position feedback signal. Operation of the transmitter requires an external dc power supply in the range of 12 Vdc (minimum) to 36 Vdc (maximum) and a load connected in series with one lead from the power supply. Power Supply Voltage - 8 Vdc 0.020A = load resistance Example: 24 Vdc - 8 Vdc 0.020A = 800 ohms maximum load WIRING TO TB4 This terminal strip is only used on models with 3W option (3 wire,120 or 240 Vac incremental control), and is located near the top of the PC board assembly. -18-
20 START UP FOR LOW LEVEL CURRENT OR VOLTAGE COMMAND SIGNALS 1) Power. Before applying AC or DC power to TB1 of the upper power supply board, as the appropriate model requires, set slide switch to the correct voltage. For DC input, slide switch position is not important. 2) Command Switch. For 4-20mA current command place dipswitch 3 in the ON (down) position. For voltage command place dipswitch 3 in the ON (down) position for 0-5Vdc or OFF (up) position for 0-10Vdc. Split range command may be enabled for a current command by placing dipswitch 4 in the ON (down) position. To select the range of the actuator place dipswitch 5 ON (down) for 12-20mA or OFF (up) for 4-12mA 3) Model Switch. For SM, VA, and LA units place dipswitch 6 in the ON (down) position. For MV units place dipswitch 6 in the OFF (up) position. 4) Auto Switch. Place DIP Switch 1 to ON (Down) to place actuator in AUTO mode. 5) Setpoints. These are the end of travel extremes corresponding to the actuator output shaft positions for low (4 ma for current command input or 0 Vdc for voltage command input); and high (20 ma for current command input, 5 Vdc for 0-5 Vdc voltage command input or 10 Vdc for 0-10 Vdc voltage command input) command signal levels. They are set by the ZERO and SPAN push buttons and adjusting knob. All settings require the holding of a push button and the turning of the adjusting knob. A) Set the command signal to lowest level, normally 4 ma. Press and hold ZERO (S1) and LOS (S5) pushbuttons until D5 is illuminated to calibrate low command value (approx. 2 seconds). B) Adjust LO setpoint (ZERO) by holding ZERO push button (S1) and turning adjusting knob to move actuator output shaft to desired ZERO position. Rotating the adjusting knob CW will cause the output shaft to extend on linear units, or rotate CW on rotary units. Rotating the adjusting knob CCW will cause the output shaft to retract on linear units, or rotate CCW on rotary units. For fine adjustments, turn the adjusting knob slowly. The knob is speed sensitive, so the faster it is turned, the more displacement of the actuator will occur. The yellow (DEC) LED will illuminate while actuator is moving toward the LO setpoint. Release button. C) Adjust transmitter low setting (4mA) by pressing and holding ZERO (S1) and LOS (S5) pushbuttons until D5 is illuminated (approx. 2 seconds). While holding pushbuttons, turn adjusting knob CW to increase transmitter low setting, or CCW to decrease setting. D) Set the command signal to highest level, normally 20 ma. Press and hold SPAN (S2) and LOS (S5) pushbuttons until D5 is illuminated to calibrate high command value (approx. 2 seconds). START-UP INFORMATION -19- E) Adjust HI setpoint (SPAN) by holding SPAN push button (S2) and turning adjusting knob to move actuator output shaft to desired SPAN position. Rotating the adjusting knob CCW will cause the output shaft to retract on linear units, or rotate CCW on rotary units. For fine adjustments, turn the adjusting knob slowly. The adjusting knob is speed sensitive, so the faster it is turned, the more displacement of the actuator will occur. The green (INC) LED will illuminate while actuator is moving toward the HI setpoint. Release button. F) Adjust transmitter high setting (20mA) by pressing and holding SPAN (S2) and LOS (S5) pushbuttons until D5 is illuminated (approx. 2 seconds). While holding pushbuttons, turn adjusting knob CW to increase transmitter high setting, or CCW to decrease transmitter high setting. G) To set up the actuator in a reverse acting fashion for linear units, set the ZERO position beyond the SPAN position, which will cause the output shaft to retract on an increasing command signal. For rotary units, set the ZERO position beyond the SPAN position, which will cause the output shaft to rotate CW on an increasing command signal. The factory setting for linear units is to extend with an increasing signal. The factory setting for rotary units is to rotate CCW with an increasing signal. 6) Deadband This adjustment establishes the actuator servo sensitivity. It is factory set at 1% and should not be field adjusted. If the actuator begins to oscillate (Green and Yellow LEDs turn on and off rapidly), decrease the sensitivity by holding deadband push button (S4) and turning adjusting knob CW until oscillation stops. Release button. 7) Speed Adjust Speed is preset at the factory. To adjust speed, hold the speed push button (S3) and turn the adjusting knob CW to increase or CCW to decrease actuator speed. Note that actuator force and speed are releted, see speed/force curves. 8) Loss of Signal Preset. This adjustment establishes the position to which the actuator will travel upon a loss of command signal condition. To activate this setting, SW2 must be OFF (Up). Adjust the setting by holding the LOS push button (S5) and turning the adjusting knob to set the preset position. Turn the adjusting knob CW to extend the feedback potentiometer, and CCW to retract it. 9) Auxiliary Limit Switches. LS-1, LS-2, LS-3 and LS-4 are available for customer use. They are adjusted with trim pots on upper PC board, and the adjacent red LEDs indicate state. 10) Verify all settings by running the actuator through its travel range several times. 11) Reset defaults. Factory presets may be restored by depressing and holding SPEED (S3), DEADBAND (S4), and LOS (S5) until D5 is illuminated (2 seconds).
21 START UP FOR INCREMENTAL CONTROL 1) Power. Before applying AC or DC power to TB1 of the upper power supply board, as the appropriate model requires, set slide switch to the correct voltage. For DC input, slide switch position is not important. 2) Command Switch. For 4-20mAcurrent command place dipswitch 3 in the ON (down) position. For voltage command place dipswitch 3 in the ON (down) position for 0-5Vdc or OFF (up) position for 0-10Vdc. Split range command may be enabled for a current command by placing dipswitch 4 in the ON (down) position. To select the range of the actuator place dipswitch 5 ON (down) for 12-20mA or OFF (up) for 4-12mA 3) Model Switch. For SM, VA, and LA units place dipswitch 6 in the ON (down) position. For MV units place dipswitch 6 in the OFF (up) position. 4) Two isolated, dry contact closures are used to position the actuator. These contacts are customer supplied and may be within a remotely located controller or may be push buttons or switches used for manual control. Do not exceed 50 feet of run length. 5) Place DIP Switch 1 to OFF (Up) position to place the actuator in manual mode. A) Close DEC contact. The actuator will move toward the low command position, and the yellow LED will illuminate. Once low command position has been reached, actuator travel will stop. B) Adjust LO setpoint (ZERO) by holding ZERO push button (S1) and turning adjusting knob to move actuator output shaft to desired position. Turn START-UP INFORMATION the adjusting knob CW to extend the output shaft, and CCW to retract the output shaft. Release button. C) Open DEC contact and then close INC contact. The actuator will move toward the high command position, and the green LED will illuminate. Once high command position has been reached, actuator travel will stop. D) Adjust HI setpoint (SPAN) by holding SPAN push button (S2) and turning adjusting knob to move actuator output shaft to desired position. Turn the adjusting knob CW to extend the feedback potentiometer, and CCW to retract the feedback potentiometer. Release button. 6) Deadband The deadband adjustment has no influence in this mode of operation. 7) Speed Adjust Speed is preset at the factory. To adjust speed, hold the speed push button (S3) and turn the adjusting knob CW to increase or CCW to decrease actuator speed. Note that actuator torque and speed are releted, see speed/torque curve on page 4. 8) Auxiliary Limit Switches. LS-1, LS-2, LS-3 and LS-4 are available for customer use. They are adjusted with trim pots on upper PC board, and the adjacent red LEDs indicate state. 9) Verify all settings by running the actuator through its travel range several times. 10) Reset defaults. Factory presets may be restored by depressing and holding SPEED (S3), DEADBAND (S4), and LOS (S5) until D5 is illuminated (approximately 2 seconds). LOWER PC BOARD DIP SWITCH CONFIGURATION ZERO ADJUST SPAN ADJUST FACTORY USE ONLY SPEED ADJUST SW1 DIPSWITCH DEADBAND ADJUST LOS ADJUST FACTORY USE ONLY WIRE FROM UPPER PC BOARD WIRE FROM UPPER PC BOARD ADJUSTMENT KNOB Switch Dip Switch Configurations SW1 Switch Position ON (DOWN) OFF (UP) ON (DOWN) OFF (UP) ON (DOWN) OFF (UP) ON (DOWN) OFF (UP) ON (DOWN) OFF (UP) ON (DOWN) OFF (UP) Function AUTO MANUAL LOS - LOCK IN PLACE LOS - GO TO PRESET 4-20 ma, 0-5 Vdc COMMAND 0-10 Vdc COMMAND Split range enabled Split range disabled ma, if split range is enabled 4-12 ma, if split range is enabled SM, VA, LA unit MV unit -20-
22 TYPICAL WIRING DIAGRAM Due to wide variations in the terminal numbering of actuator products, actual wiring should follow the print supplied with the actuator. VISUAL TROUBLESHOOTING TROUBLESHOOTING GUIDE For visual troubleshooting, LEDs are provided to display the status of the actuator. These are located on the same side of the lower board as SW1. The identification of these LEDs are shown in the table below, and are ordered as the LEDs appear: left to right. LED Microprocessor running (D4) Actuator Increasing Actuator Decreasing Fault Function This LED flashes when the microprocessor is running. If this is not on, verify power to the board. This LED is on when the actuator is moving in the increasing direction This LED is on when the actuator is moving in the decreasing direction. 1 Flash - Indicates a loss of 4-20 ma signal (LOS). 2 Flashes - Indicates a stall condition. 3 Flashes - Indicates an electronic component failure. -21-
23
24 The dimensions in this manual are subject to change without notice and should not be used for preparation of drawings or fabrication of installation mounting. Current installation dimension drawings are available upon request. JORDAN CONTROLS, INC West Douglas Avenue Milwaukee, Wisconsin Phone: (414) FAX: (414) IM /04-22-
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER
FILE: IM_091-120-12E-20 Rev A., 05-06-08 INSTRUCTION MANUAL AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER R MODEL #091-120-12E-20 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the ODYSSEY
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas
SFS81 Series Servo Finishing Stand PUSHCORP, INC. Dallas, Texas May, 2012 NEVER OPERATE THE SFS81 MANUALLY NEVER OPERATE THE SFS81 WITH PERSONEL IN THE WORKCELL DO NOT USE LUBRICATED AIR. This device requires
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual
Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
Servo Info and Centering
Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor
Seven function digital multimeter
Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown
NEX-3004 AUGUST 4, 2015 Fireye NEXUS FX04 and FX04-1 Servo Motor Installation FX04-1 Shown DESCRIPTION This bulletin describes the installation and operating instructions for the FX04 and FX04-1, 3 lb.-ft./
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
Load Cell Amplifier Module. Instruction Manual LCA210-000
Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4
KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual
KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
Fisher 377 Trip Valve
377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls
Series 71, 72, and 76 Modutrol IV Motors
Series 7, 7, and 76 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 7, 7 and 76 Modutrol IV Motors are spring return and nonspring return motors used to control dampers and valves. The
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.
BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER Installation, Operation, and Maintenance Instructions Manual No. M06-512 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY BROOKFIELD
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
Analog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Installation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
User Manual. CFG253 3 MHz Function Generator 070-8362-04
User Manual CFG253 3 MHz Function Generator 070-8362-04 Copyright Tektronix, Inc. 1993. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information
User's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
Model 349KLX Remote Display Digital Scale User Instructions
Model 349KLX Remote Display Digital Scale User Instructions P/N UM349KLX Rev 3-080713 1 Model 349KLX Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully,
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
Short Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Installation and Operation Guide for PD4100 Series Power Control Centers
Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0
Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V
Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input
MDC151-024031 Series
MDC151-024031 Series 24V, 3A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected] (714) 992-6990 fax: (714)
Machine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Periodic Verification System Model 775PVS
Periodic Verification System Model 775PVS Instruction Manual Contents 1 Description... 1 775PVS System... 1 Model 775 Fieldmeter... 2 Model 775C Charger... 2 Model 775P Plate Assembly... 3 2 Operation...
Know-how makes the difference. Electrical Actuators
Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product
Electronic Power Control
Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need
DC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 82IP-303A0ME E1 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Comfort Control Relay Panel (CCRP)
CCRP9 "Commitment to Innovation" OPERATION & INSTALLATION GUIDE FOR Comfort Control Panel (CCRP) Off-Peak System Control 9 Pole CCRP 4 Pole CCRP (Applicable to Software Version 14.0-14.9) "Manufactured
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
Incremental Rotary Encoder E6B2
Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811
Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The
Ground Resistance Clamp-On Tester
User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one
Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE
Service Information Calibration & Adjustments CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS Part Number DYN1-10752-000-0-12/24 DYN1-10752-001-0-12/24* DYN1-10753-000-0-12/24